KNX Interface for energy meters TXF121

Hager Electro · Order number TXF121 · Meter › Compteur d'énergie

Download .knxprod STXF121 1.0 · 156 KB

Product

ManufacturerHager Electro
Product nameKNX Interface for energy meters
Order numberTXF121
HardwareTXF121
MediumTwisted Pair
Bus current (mA)6
Rail mountedYes
RegistrationRegistered · 2019-12-16
Languagesfr-FR, da-DK, de-DE, en-US, es-ES, it-IT, nl-NL, pt-PT, nb-NO, sv-SE
Catalog entryM-0009_H-9.20.2F.2F.20TXF121-16_HP-E0EE-10-ADF8_CI-TXF121-1
FingerprintADF8
SHA-256414172b993e374472e8478e746c44493288ee16fb763d4ee7d9347a098b244ea
First seen2026-11-25
Markets69 markets

Application program: STXF121 1.0

Application number$E0EE
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters160
Group objects300
Group objects (300)
NoNameFunctionSizeDPTFlags
1{{0:Input 1 metering}}Tariff1 Byte5.6 tariff (0..255)CWTU
1{{0:Input 2 metering}}Tariff1 Byte5.6 tariff (0..255)CWTU
1{{0:Input 3 metering}}Tariff1 Byte5.6 tariff (0..255)CWTU
1{{0:Addition metering}}Tariff1 Byte5.6 tariff (0..255)CWTU
2{{0:Input 1 metering}}Active power4 Bytes14.56 power (W)CRT
2{{0:Input 2 metering}}Active power4 Bytes14.56 power (W)CRT
2{{0:Input 3 metering}}Active power4 Bytes14.56 power (W)CRT
2{{0:Addition metering}}Active power4 Bytes14.56 power (W)CRT
3{{0:Input 1 metering}}Apparent power4 BytesDPT.14CRT
3{{0:Input 2 metering}}Apparent power4 BytesDPT.14CRT
3{{0:Input 3 metering}}Apparent power4 BytesDPT.14CRT
3{{0:Addition metering}}Apparent power4 BytesDPT.14CRT
4{{0:Input 1 metering}}Reactive power4 BytesDPT.14CRT
4{{0:Input 2 metering}}Reactive power4 BytesDPT.14CRT
4{{0:Input 3 metering}}Reactive power4 BytesDPT.14CRT
4{{0:Addition metering}}Reactive power4 BytesDPT.14CRT
5{{0:Input 1 metering}}Total imported active energy6 Bytes235.1 electrical energy with tariffCRT
5{{0:Input 2 metering}}Total imported active energy6 Bytes235.1 electrical energy with tariffCRT
5{{0:Input 3 metering}}Total imported active energy6 Bytes235.1 electrical energy with tariffCRT
5{{0:Addition metering}}Total imported active energy6 Bytes235.1 electrical energy with tariffCRT
6{{0:Input 1 metering}}Total imported active energy T14 Bytes13.10 active energy (Wh)CRT
6{{0:Input 2 metering}}Total imported active energy T14 Bytes13.10 active energy (Wh)CRT
6{{0:Input 3 metering}}Total imported active energy T14 Bytes13.10 active energy (Wh)CRT
6{{0:Addition metering}}Total imported active energy T14 Bytes13.10 active energy (Wh)CRT
7{{0:Input 1 metering}}Total imported active energy T24 Bytes13.10 active energy (Wh)CRT
7{{0:Input 2 metering}}Total imported active energy T24 Bytes13.10 active energy (Wh)CRT
7{{0:Input 3 metering}}Total imported active energy T24 Bytes13.10 active energy (Wh)CRT
7{{0:Addition metering}}Total imported active energy T24 Bytes13.10 active energy (Wh)CRT
8{{0:Input 1 metering}}Total imported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
8{{0:Input 1 metering}}Total imported active energy4 Bytes13.10 active energy (Wh)CRT
8{{0:Input 2 metering}}Total imported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
8{{0:Input 2 metering}}Total imported active energy4 Bytes13.10 active energy (Wh)CRT
8{{0:Input 3 metering}}Total imported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
8{{0:Input 3 metering}}Total imported active energy4 Bytes13.10 active energy (Wh)CRT
8{{0:Addition metering}}Total imported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
8{{0:Addition metering}}Total imported active energy4 Bytes13.10 active energy (Wh)CRT
9{{0:Input 1 metering}}Total exported active energy6 Bytes235.1 electrical energy with tariffCRT
9{{0:Input 2 metering}}Total exported active energy6 Bytes235.1 electrical energy with tariffCRT
9{{0:Input 3 metering}}Total exported active energy6 Bytes235.1 electrical energy with tariffCRT
9{{0:Addition metering}}Total exported active energy6 Bytes235.1 electrical energy with tariffCRT
10{{0:Input 1 metering}}Total exported active energy T14 Bytes13.10 active energy (Wh)CRT
10{{0:Input 2 metering}}Total exported active energy T14 Bytes13.10 active energy (Wh)CRT
10{{0:Input 3 metering}}Total exported active energy T14 Bytes13.10 active energy (Wh)CRT
10{{0:Addition metering}}Total exported active energy T14 Bytes13.10 active energy (Wh)CRT
11{{0:Input 1 metering}}Total exported active energy T24 Bytes13.10 active energy (Wh)CRT
11{{0:Input 2 metering}}Total exported active energy T24 Bytes13.10 active energy (Wh)CRT
11{{0:Input 3 metering}}Total exported active energy T24 Bytes13.10 active energy (Wh)CRT
11{{0:Addition metering}}Total exported active energy T24 Bytes13.10 active energy (Wh)CRT
12{{0:Input 1 metering}}Total exported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
12{{0:Input 1 metering}}Total exported active energy4 Bytes13.10 active energy (Wh)CRT
12{{0:Input 2 metering}}Total exported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
12{{0:Input 2 metering}}Total exported active energy4 Bytes13.10 active energy (Wh)CRT
12{{0:Input 3 metering}}Total exported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
12{{0:Input 3 metering}}Total exported active energy4 Bytes13.10 active energy (Wh)CRT
12{{0:Addition metering}}Total exported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
12{{0:Addition metering}}Total exported active energy4 Bytes13.10 active energy (Wh)CRT
13{{0:Input 1 metering}}Total imported reactive energy6 Bytes235.1 electrical energy with tariffCRT
13{{0:Input 2 metering}}Total imported reactive energy6 Bytes235.1 electrical energy with tariffCRT
13{{0:Input 3 metering}}Total imported reactive energy6 Bytes235.1 electrical energy with tariffCRT
13{{0:Addition metering}}Total imported reactive energy6 Bytes235.1 electrical energy with tariffCRT
14{{0:Input 1 metering}}Total imported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
14{{0:Input 2 metering}}Total imported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
14{{0:Input 3 metering}}Total imported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
14{{0:Addition metering}}Total imported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
15{{0:Input 1 metering}}Total imported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
15{{0:Input 2 metering}}Total imported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
15{{0:Input 3 metering}}Total imported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
15{{0:Addition metering}}Total imported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
16{{0:Input 1 metering}}Total imported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
16{{0:Input 1 metering}}Total imported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
16{{0:Input 2 metering}}Total imported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
16{{0:Input 2 metering}}Total imported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
16{{0:Input 3 metering}}Total imported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
16{{0:Input 3 metering}}Total imported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
16{{0:Addition metering}}Total imported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
16{{0:Addition metering}}Total imported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
17{{0:Input 1 metering}}Total exported reactive energy6 Bytes235.1 electrical energy with tariffCRT
17{{0:Input 2 metering}}Total exported reactive energy6 Bytes235.1 electrical energy with tariffCRT
17{{0:Input 3 metering}}Total exported reactive energy6 Bytes235.1 electrical energy with tariffCRT
17{{0:Addition metering}}Total exported reactive energy6 Bytes235.1 electrical energy with tariffCRT
18{{0:Input 1 metering}}Total exported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
18{{0:Input 2 metering}}Total exported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
18{{0:Input 3 metering}}Total exported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
18{{0:Addition metering}}Total exported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
19{{0:Input 1 metering}}Total exported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
19{{0:Input 2 metering}}Total exported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
19{{0:Input 3 metering}}Total exported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
19{{0:Addition metering}}Total exported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
20{{0:Input 1 metering}}Total exported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
20{{0:Input 1 metering}}Total exported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
20{{0:Input 2 metering}}Total exported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
20{{0:Input 2 metering}}Total exported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
20{{0:Input 3 metering}}Total exported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
20{{0:Input 3 metering}}Total exported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
20{{0:Addition metering}}Total exported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
20{{0:Addition metering}}Total exported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
21{{0:Input 1 metering}}Partial imported active energy6 Bytes235.1 electrical energy with tariffCRT
21{{0:Input 2 metering}}Partial imported active energy6 Bytes235.1 electrical energy with tariffCRT
21{{0:Input 3 metering}}Partial imported active energy6 Bytes235.1 electrical energy with tariffCRT
21{{0:Addition metering}}Partial imported active energy6 Bytes235.1 electrical energy with tariffCRT
22{{0:Input 1 metering}}Partial imported active energy T14 Bytes13.10 active energy (Wh)CRT
22{{0:Input 2 metering}}Partial imported active energy T14 Bytes13.10 active energy (Wh)CRT
22{{0:Input 3 metering}}Partial imported active energy T14 Bytes13.10 active energy (Wh)CRT
22{{0:Addition metering}}Partial imported active energy T14 Bytes13.10 active energy (Wh)CRT
23{{0:Input 1 metering}}Partial imported active energy T24 Bytes13.10 active energy (Wh)CRT
23{{0:Input 2 metering}}Partial imported active energy T24 Bytes13.10 active energy (Wh)CRT
23{{0:Input 3 metering}}Partial imported active energy T24 Bytes13.10 active energy (Wh)CRT
23{{0:Addition metering}}Partial imported active energy T24 Bytes13.10 active energy (Wh)CRT
24{{0:Input 1 metering}}Partial imported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
24{{0:Input 1 metering}}Partial imported active energy4 Bytes13.10 active energy (Wh)CRT
24{{0:Input 2 metering}}Partial imported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
24{{0:Input 2 metering}}Partial imported active energy4 Bytes13.10 active energy (Wh)CRT
24{{0:Input 3 metering}}Partial imported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
24{{0:Input 3 metering}}Partial imported active energy4 Bytes13.10 active energy (Wh)CRT
24{{0:Addition metering}}Partial imported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
24{{0:Addition metering}}Partial imported active energy4 Bytes13.10 active energy (Wh)CRT
25{{0:Input 1 metering}}Partial exported active energy6 Bytes235.1 electrical energy with tariffCRT
25{{0:Input 2 metering}}Partial exported active energy6 Bytes235.1 electrical energy with tariffCRT
25{{0:Input 3 metering}}Partial exported active energy6 Bytes235.1 electrical energy with tariffCRT
25{{0:Addition metering}}Partial exported active energy6 Bytes235.1 electrical energy with tariffCRT
26{{0:Input 1 metering}}Partial exported active energy T14 Bytes13.10 active energy (Wh)CRT
26{{0:Input 2 metering}}Partial exported active energy T14 Bytes13.10 active energy (Wh)CRT
26{{0:Input 3 metering}}Partial exported active energy T14 Bytes13.10 active energy (Wh)CRT
26{{0:Addition metering}}Partial exported active energy T14 Bytes13.10 active energy (Wh)CRT
27{{0:Input 1 metering}}Partial exported active energy T24 Bytes13.10 active energy (Wh)CRT
27{{0:Input 2 metering}}Partial exported active energy T24 Bytes13.10 active energy (Wh)CRT
27{{0:Input 3 metering}}Partial exported active energy T24 Bytes13.10 active energy (Wh)CRT
27{{0:Addition metering}}Partial exported active energy T24 Bytes13.10 active energy (Wh)CRT
28{{0:Input 1 metering}}Partial exported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
28{{0:Input 1 metering}}Partial exported active energy4 Bytes13.10 active energy (Wh)CRT
28{{0:Input 2 metering}}Partial exported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
28{{0:Input 2 metering}}Partial exported active energy4 Bytes13.10 active energy (Wh)CRT
28{{0:Input 3 metering}}Partial exported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
28{{0:Input 3 metering}}Partial exported active energy4 Bytes13.10 active energy (Wh)CRT
28{{0:Addition metering}}Partial exported active energy T1 + T24 Bytes13.10 active energy (Wh)CRT
28{{0:Addition metering}}Partial exported active energy4 Bytes13.10 active energy (Wh)CRT
29{{0:Input 1 metering}}Partial imported reactive energy6 Bytes235.1 electrical energy with tariffCRT
29{{0:Input 2 metering}}Partial imported reactive energy6 Bytes235.1 electrical energy with tariffCRT
29{{0:Input 3 metering}}Partial imported reactive energy6 Bytes235.1 electrical energy with tariffCRT
29{{0:Addition metering}}Partial imported reactive energy6 Bytes235.1 electrical energy with tariffCRT
30{{0:Input 1 metering}}Partial imported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
30{{0:Input 2 metering}}Partial imported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
30{{0:Input 3 metering}}Partial imported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
30{{0:Addition metering}}Partial imported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
31{{0:Input 1 metering}}Partial imported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
31{{0:Input 2 metering}}Partial imported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
31{{0:Input 3 metering}}Partial imported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
31{{0:Addition metering}}Partial imported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
32{{0:Input 1 metering}}Partial imported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
32{{0:Input 1 metering}}Partial imported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
32{{0:Input 2 metering}}Partial imported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
32{{0:Input 2 metering}}Partial imported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
32{{0:Input 3 metering}}Partial imported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
32{{0:Input 3 metering}}Partial imported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
32{{0:Addition metering}}Partial imported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
32{{0:Addition metering}}Partial imported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
33{{0:Input 1 metering}}Partial exported reactive energy6 Bytes235.1 electrical energy with tariffCRT
33{{0:Input 2 metering}}Partial exported reactive energy6 Bytes235.1 electrical energy with tariffCRT
33{{0:Input 3 metering}}Partial exported reactive energy6 Bytes235.1 electrical energy with tariffCRT
33{{0:Addition metering}}Partial exported reactive energy6 Bytes235.1 electrical energy with tariffCRT
34{{0:Input 1 metering}}Partial exported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
34{{0:Input 2 metering}}Partial exported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
34{{0:Input 3 metering}}Partial exported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
34{{0:Addition metering}}Partial exported reactive energy T14 Bytes13.12 reactive energy (VARh)CRT
35{{0:Input 1 metering}}Partial exported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
35{{0:Input 2 metering}}Partial exported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
35{{0:Input 3 metering}}Partial exported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
35{{0:Addition metering}}Partial exported reactive energy T24 Bytes13.12 reactive energy (VARh)CRT
36{{0:Input 1 metering}}Partial exported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
36{{0:Input 1 metering}}Partial exported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
36{{0:Input 2 metering}}Partial exported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
36{{0:Input 2 metering}}Partial exported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
36{{0:Input 3 metering}}Partial exported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
36{{0:Input 3 metering}}Partial exported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
36{{0:Addition metering}}Partial exported reactive energy T1 + T24 Bytes13.12 reactive energy (VARh)CRT
36{{0:Addition metering}}Partial exported reactive energy4 Bytes13.12 reactive energy (VARh)CRT
37{{0:Input 1 metering}}Voltage4 Bytes14.27 electric potential (V)CRT
37{{0:Input 2 metering}}Voltage4 Bytes14.27 electric potential (V)CRT
37{{0:Input 3 metering}}Voltage4 Bytes14.27 electric potential (V)CRT
37{{0:Addition metering}}Voltage4 Bytes14.27 electric potential (V)CRT
38{{0:Input 1 metering}}Current4 Bytes14.19 electric current (A)CRT
38{{0:Input 2 metering}}Current4 Bytes14.19 electric current (A)CRT
38{{0:Input 3 metering}}Current4 Bytes14.19 electric current (A)CRT
38{{0:Addition metering}}Current4 Bytes14.19 electric current (A)CRT
39{{0:Input 1 metering}}Power factor4 Bytes14.57 power factor (cos Φ)CRT
39{{0:Input 2 metering}}Power factor4 Bytes14.57 power factor (cos Φ)CRT
39{{0:Input 3 metering}}Power factor4 Bytes14.57 power factor (cos Φ)CRT
39{{0:Addition metering}}Power factor4 Bytes14.57 power factor (cos Φ)CRT
40{{0:Input 1 metering}}Energy direction1 BitDPT.1CRT
40{{0:Input 2 metering}}Energy direction1 BitDPT.1CRT
40{{0:Input 3 metering}}Energy direction1 BitDPT.1CRT
40{{0:Addition metering}}Energy direction1 BitDPT.1CRT
41{{0:Input 1 metering}}Reactive energy type1 BitDPT.1CRT
41{{0:Input 2 metering}}Reactive energy type1 BitDPT.1CRT
41{{0:Input 3 metering}}Reactive energy type1 BitDPT.1CRT
41{{0:Addition metering}}Reactive energy type1 BitDPT.1CRT
42{{0:Input 1 metering}}Active power timestamped12 BytesCRT
42{{0:Input 2 metering}}Active power timestamped12 BytesCRT
42{{0:Input 3 metering}}Active power timestamped12 BytesCRT
42{{0:Addition metering}}Active power timestamped12 BytesCRT
43{{0:Input 1 metering}}Apparent power timestamped12 BytesCRT
43{{0:Input 2 metering}}Apparent power timestamped12 BytesCRT
43{{0:Input 3 metering}}Apparent power timestamped12 BytesCRT
43{{0:Addition metering}}Apparent power timestamped12 BytesCRT
44{{0:Input 1 metering}}Reactive power timestamped12 BytesCRT
44{{0:Input 2 metering}}Reactive power timestamped12 BytesCRT
44{{0:Input 3 metering}}Reactive power timestamped12 BytesCRT
44{{0:Addition metering}}Reactive power timestamped12 BytesCRT
45{{0:Input 1 metering}}Total imported active energy timestamped14 BytesCRT
45{{0:Input 2 metering}}Total imported active energy timestamped14 BytesCRT
45{{0:Input 3 metering}}Total imported active energy timestamped14 BytesCRT
45{{0:Addition metering}}Total imported active energy timestamped14 BytesCRT
46{{0:Input 1 metering}}Total exported active energy timestamped14 BytesCRT
46{{0:Input 2 metering}}Total exported active energy timestamped14 BytesCRT
46{{0:Input 3 metering}}Total exported active energy timestamped14 BytesCRT
46{{0:Addition metering}}Total exported active energy timestamped14 BytesCRT
47{{0:Input 1 metering}}Total imported reactive energy timestamped14 BytesCRT
47{{0:Input 2 metering}}Total imported reactive energy timestamped14 BytesCRT
47{{0:Input 3 metering}}Total imported reactive energy timestamped14 BytesCRT
47{{0:Addition metering}}Total imported reactive energy timestamped14 BytesCRT
48{{0:Input 1 metering}}Total exported reactive energy timestamped14 BytesCRT
48{{0:Input 2 metering}}Total exported reactive energy timestamped14 BytesCRT
48{{0:Input 3 metering}}Total exported reactive energy timestamped14 BytesCRT
48{{0:Addition metering}}Total exported reactive energy timestamped14 BytesCRT
49{{0:Input 1 metering}}Partial imported active energy timestamped14 BytesCRT
49{{0:Input 2 metering}}Partial imported active energy timestamped14 BytesCRT
49{{0:Input 3 metering}}Partial imported active energy timestamped14 BytesCRT
49{{0:Addition metering}}Partial imported active energy timestamped14 BytesCRT
50{{0:Input 1 metering}}Partial exported active energy timestamped14 BytesCRT
50{{0:Input 2 metering}}Partial exported active energy timestamped14 BytesCRT
50{{0:Input 3 metering}}Partial exported active energy timestamped14 BytesCRT
50{{0:Addition metering}}Partial exported active energy timestamped14 BytesCRT
51{{0:Input 1 metering}}Partial imported reactive energy timestamped14 BytesCRT
51{{0:Input 2 metering}}Partial imported reactive energy timestamped14 BytesCRT
51{{0:Input 3 metering}}Partial imported reactive energy timestamped14 BytesCRT
51{{0:Addition metering}}Partial imported reactive energy timestamped14 BytesCRT
52{{0:Input 1 metering}}Partial exported reactive energy timestamped14 BytesCRT
52{{0:Input 2 metering}}Partial exported reactive energy timestamped14 BytesCRT
52{{0:Input 3 metering}}Partial exported reactive energy timestamped14 BytesCRT
52{{0:Addition metering}}Partial exported reactive energy timestamped14 BytesCRT
53{{0:Input 1 metering}}Voltage timestamped12 BytesCRT
53{{0:Input 2 metering}}Voltage timestamped12 BytesCRT
53{{0:Input 3 metering}}Voltage timestamped12 BytesCRT
53{{0:Addition metering}}Voltage timestamped12 BytesCRT
54{{0:Input 1 metering}}Current timestamped12 BytesCRT
54{{0:Input 2 metering}}Current timestamped12 BytesCRT
54{{0:Input 3 metering}}Current timestamped12 BytesCRT
54{{0:Addition metering}}Current timestamped12 BytesCRT
55{{0:Input 1 metering}}Power factor timestamped12 BytesCRT
55{{0:Input 2 metering}}Power factor timestamped12 BytesCRT
55{{0:Input 3 metering}}Power factor timestamped12 BytesCRT
55{{0:Addition metering}}Power factor timestamped12 BytesCRT
56{{0:Input 1 metering}}Energy direction timestamped9 BytesCRT
56{{0:Input 2 metering}}Energy direction timestamped9 BytesCRT
56{{0:Input 3 metering}}Energy direction timestamped9 BytesCRT
56{{0:Addition metering}}Energy direction timestamped9 BytesCRT
57{{0:Input 1 metering}}Reactive energy type timestamped9 BytesCRT
57{{0:Input 2 metering}}Reactive energy type timestamped9 BytesCRT
57{{0:Input 3 metering}}Reactive energy type timestamped9 BytesCRT
57{{0:Addition metering}}Reactive energy type timestamped9 BytesCRT
58{{0:Input 1 metering}}Dynamic mode activation1 Bit1.3 enableCWTU
58{{0:Input 2 metering}}Dynamic mode activation1 Bit1.3 enableCWTU
58{{0:Input 3 metering}}Dynamic mode activation1 Bit1.3 enableCWTU
58{{0:Addition metering}}Dynamic mode activation1 Bit1.3 enableCWTU
59{{0:Input 1 metering}}Partial meter reset1 Bit1.15 resetCWTU
59{{0:Input 2 metering}}Partial meter reset1 Bit1.15 resetCWTU
59{{0:Input 3 metering}}Partial meter reset1 Bit1.15 resetCWTU
59{{0:Addition metering}}Partial meter reset1 Bit1.15 resetCWTU
60{{0:Input 1 metering}}History request1 Bit1.17 triggerCWTU
60{{0:Input 2 metering}}History request1 Bit1.17 triggerCWTU
60{{0:Input 3 metering}}History request1 Bit1.17 triggerCWTU
60{{0:Addition metering}}History request1 Bit1.17 triggerCWTU
61{{0:Input 1 metering}}Overvoltage alarm1 Bit1.5 alarmCRT
61{{0:Input 2 metering}}Overvoltage alarm1 Bit1.5 alarmCRT
61{{0:Input 3 metering}}Overvoltage alarm1 Bit1.5 alarmCRT
61{{0:Addition metering}}Overvoltage alarm1 Bit1.5 alarmCRT
62{{0:Input 1 metering}}Undervoltage alarm1 Bit1.5 alarmCRT
62{{0:Input 2 metering}}Undervoltage alarm1 Bit1.5 alarmCRT
62{{0:Input 3 metering}}Undervoltage alarm1 Bit1.5 alarmCRT
62{{0:Addition metering}}Undervoltage alarm1 Bit1.5 alarmCRT
63{{0:Input 1 metering}}Overconsumption alarm1 Bit1.5 alarmCRT
63{{0:Input 2 metering}}Overconsumption alarm1 Bit1.5 alarmCRT
63{{0:Input 3 metering}}Overconsumption alarm1 Bit1.5 alarmCRT
63{{0:Addition metering}}Overconsumption alarm1 Bit1.5 alarmCRT
64{{0:Input 1 metering}}Overconsumption threshold4 Bytes14.19 electric current (A)CWTU
64{{0:Input 2 metering}}Overconsumption threshold4 Bytes14.19 electric current (A)CWTU
64{{0:Input 3 metering}}Overconsumption threshold4 Bytes14.19 electric current (A)CWTU
64{{0:Addition metering}}Overconsumption threshold4 Bytes14.19 electric current (A)CWTU
257GeneralTariff1 Byte5.6 tariff (0..255)CRT
258GeneralDate3 Bytes11.1 dateCWTU
259GeneralTime3 Bytes10.1 time of dayCWTU
260GeneralDate and time8 Bytes19.1 date timeCWTU
261GeneralDate and time request1 Bit1.17 triggerCRT
262GeneralDevice LED switch off1 Bit1.1 switchCWTU
263GeneralWrong meter type1 Bit1.5 alarmCRT
264GeneralMeter communication loss1 Bit1.5 alarmCRT
265GeneralNet frequency4 Bytes14.33 frequency (Hz)CRT
266GeneralMeter serial number14 Bytes16.0 Character String (ASCII)CRT
267GeneralPhase sequence error1 Bit1.5 alarmCRT
268GeneralRestore ETS-params settings1 Bit1.1 switchCWTU
Parameters (96)
ParameterTypeDefault
Tariff inputunsignedInt 0…10
Date and time objectslist2 objects (3 bytes + 3 bytes)
Exported energyunsignedInt 0…10
TimestampunsignedInt 0…11
Energy object formatlist6 bytes (energy + tariff information)
Application software versiontext1.0.6
Version of translation filelist6
Activ. of restore ETS-parameters objectunsignedInt 0…10
Meter typelistSingle-phase
Value emission by variation ofunsignedInt 0…655350
Datapoints initialization delaytime0
Emission of value everytime600
EmissionlistOn change and periodically
Date and time request delay at initializationtime10
CH7_Dummy1unsignedInt 0…70
Restore ETS-params settingsunsignedInt 0…10
Phase sequence alarmlist0 = Alarm deactivated, 1 = Alarm activated
Meter communication lost alarmlist0 = Alarm deactivated, 1 = Alarm activated
Wrong meter alarmlist0 = Alarm deactivated, 1 = Alarm activated
Device LED switch offlist0 = Status indication, 1 = Always OFF
LED behaviourlistON
Value meter index tariff T1unsignedInt 0…101
Value meter index tariff T2unsignedInt 0…102
Meter communication timeouttime10
Energy pulse weightunsignedInt 0…655351
Objects emission delay at bus returntime20
Value emission by variation ofunsignedInt 0…655355000
Init delaytime0
Emission of value everytime1800
Value emission by variation ofunsignedInt 0…655351
Init delaytime3
Emission of value everytime3600
Init delaytime1
Value emission by variation offloat 0.001…65.5355
CH7_Dummy2unsignedInt 0…2550
CH7_Dummy3unsignedInt 0…2550
Reactive energyunsignedInt 0…10
Value meter index tariff T3unsignedInt 0…103
Value meter index tariff T4unsignedInt 0…104
Value meter index tariff T5unsignedInt 0…105
Value meter index tariff T6unsignedInt 0…106
Value meter index tariff T7unsignedInt 0…107
Value meter index tariff T8unsignedInt 0…108
Number of meter's tariffslist2 tariffs
Ch7_Dummy4unsignedInt 0…655350
Dynamic mode activation polaritylist1 = Start, 0 = Stop
Input metering nametext
Dynamic mode durationtime900
Emission of power (dynamic mode) by variation ofunsignedInt 0…6553510
Partial meter reset polaritylistReset by 1
History request polaritylist1 = Start, 0 = Stop
Overvoltage thresholdunsignedInt 0…655352760
Undervoltage thresholdunsignedInt 0…655351840
Voltage threshold hysteresisunsignedInt 0…65535100
Undervoltage alarm polaritylist0 = Alarm deactivated, 1 = Alarm activated
Overvoltage alarm polaritylist0 = Alarm deactivated, 1 = Alarm activated
Overconsumption thresholdunsignedInt 0…6553550
Overconsumption hysteresisunsignedInt 0…655355
Overconsumption alarm polaritylist0 = Alarm deactivated, 1 = Alarm activated
Energy direction polaritylist0 = Import, 1 = Export
Reactive energy type polaritylist0 = Inductive, 1 = Capacitive
Complete energy meters synchronization delaytime1800
Interframe delay on energy meters emissiontime1
Interframe delay on history emissiontime2
Historic depth transmittedunsignedInt 0…65535744
Value emission by variation ofunsignedInt 1…65535500
Emission of value everytime300
Value emission by variation ofunsignedInt 1…65535100
Init delaytime8
Emission of value everytime900
Init delaytime19
Init delaytime52
Init delaytime63
Init delaytime30
Init delaytime41
Init delaytime74
Init delaytime85
Value emission by variation ofunsignedInt 1…655355000
Init delaytime2
Value emission by variation ofunsignedInt 1…655352000
Value emission by variation ofunsignedInt 0…6553550
Init delaytime4
Init delaytime5
Init delaytime6
Init delaytime7
Overconsumption hysteresisfloat 0.1…6553.50.5
Overconsumption thresholdfloat 0.1…6553.55
Voltage threshold hysteresisfloat 0.1…5010
Undervoltage thresholdfloat 184…276184
Overvoltage thresholdfloat 184…276276
TariffAllocation_VlistTariff from KNX bus
Tariff input selectionlistTariff from KNX bus
Value emission by variation offloat 0.001…65.5352
Value emission by variation offloat 0.001…10.05
ConditionalEnergy_VunsignedInt 0…2550
EnergyDisplayunsignedInt 0…2551

Version history

ApplicationApp noFingerprintFirst seenSizeFile
STXF121 1.0 latest$E0EEADF82026-11-25156 KBDownload

About this file

This is the official ETS product database for the Hager Electro KNX Interface for energy meters (TXF121), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Hager Electro