KNX Database
GVS ARSA-04/xx.S Switch Actuator with Secure, 4-Fold

Switch Actuator with Secure, 4-Fold ARSA-04/xx.S

GVS · Order number ARSA-04/xx.S · Actuator › Switch

Download .knxprod Switch Actuator with Secure, 4-Fold/3.0 3.0 · 182 KB

Product

ManufacturerGVS
Product nameSwitch Actuator with Secure, 4-Fold
Order numberARSA-04/xx.S
HardwareARSA-04/xx.S
MediumTwisted Pair
Bus current (mA)6.5
Rail mountedYes
Width (mm)72
RegistrationCertified · 2023-05-03
Languagesde-DE, en-US, zh-CN
Catalog entryM-0085_H-AR22ED-1_HP-0085-30-A90E_CI-ARSA.2D04.2Fxx.2ES-1
FingerprintA90E
SHA-256d2e8baa56c4406b9e3e7cee3ba59d3b4e02a5d202746a0dcb14f9fd334f3d834
First seen2026-11-25
Markets69 markets

Application program: Switch Actuator with Secure, 4-Fold/3.0 3.0

Application number$0085
Version3.0
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters550
Group objects154
Group objects (154)
NoNameFunctionSizeDPTFlags
1GeneralIn operation1 Bit1.1 switchCRT
2GeneralSafety priority 11 Bit1.3 enableCWU
3GeneralSafety priority 21 Bit1.3 enableCWU
4Output A-{{0:...}}Switch status1 Bit1.1 switchCRT
5Output A-{{0:...}}Switch1 Bit1.1 switchCW
5Output A-{{0:...}}On-Off1 Bit1.1 switchCW
6Output A-{{0:...}}Status (continuous),1 bit 1 Bit1.1 switchCRT
6Output A-{{0:...}}Switch out with delay1 Bit1.1 switchCW
6Output A-{{0:...}}Switch out with flashing1 Bit1.1 switchCW
6Output A-{{0:...}}Output of staircase lighting1 Bit1.1 switchCW
7Output A-{{0:...}}Switch time function1 Bit1.3 enableCW
8Output A-{{0:...}}Warning of staircase 1 Bit1.5 alarmCT
8Output A-{{0:...}}Report fault1 Bit1.5 alarmCRT
9Output A-{{0:...}}Duration of staircase 2 Bytes7.5 time (s)CRW
10Output A-{{0:...}}Recall preset1 Bit1.22 sceneCW
11Output A-{{0:...}}Store preset1 Bit1.22 sceneCW
11Output A-{{0:...}}Trigger switch regularly 1 Bit1.3 enableCW
12Output A-{{0:...}}Input 1 of logic 1 Bit1.2 booleanCW
13Output A-{{0:...}}Input 2 of logic 1 Bit1.2 booleanCW
14Output A-{{0:...}}Status (continuous),1 byte1 Byte5.1 percentage (0..100%)CRT
14Output A-{{0:...}}Scene1 Byte18.1 scene controlCW
15Output A-{{0:...}}Continuous control1 Byte5.1 percentage (0..100%)CW
15Output A-{{0:...}}Change threshold 11 Byte5.10 counter pulses (0..255)CW
16Output A-{{0:...}}Threshold input 1 Byte5.10 counter pulses (0..255)CW
17Output A-{{0:...}}Forced operation1 Bit1.1 switchCW
17Output A-{{0:...}}Forced operation2 Bit2.1 switch controlCW
17Output A-{{0:...}}Forced operation1 Bit1.3 enableCW
18Output B-{{0:...}}Switch status1 Bit1.1 switchCRT
19Output B-{{0:...}}Switch1 Bit1.1 switchCW
19Output B-{{0:...}}On-Off1 Bit1.1 switchCW
20Output B-{{0:...}}Switch out with delay1 Bit1.1 switchCW
20Output B-{{0:...}}Switch out with flashing1 Bit1.1 switchCW
20Output B-{{0:...}}Output of staircase lighting1 Bit1.1 switchCW
20Output B-{{0:...}}Status (continuous),1 bit 1 Bit1.1 switchCRT
21Output B-{{0:...}}Switch time function1 Bit1.3 enableCW
22Output B-{{0:...}}Warning of staircase 1 Bit1.5 alarmCT
22Output B-{{0:...}}Report fault1 Bit1.5 alarmCRT
23Output B-{{0:...}}Duration of staircase 2 Bytes7.5 time (s)CRW
24Output B-{{0:...}}Recall preset1 Bit1.22 sceneCW
25Output B-{{0:...}}Store preset1 Bit1.22 sceneCW
25Output B-{{0:...}}Trigger switch regularly 1 Bit1.3 enableCW
26Output B-{{0:...}}Input 1 of logic 1 Bit1.2 booleanCW
27Output B-{{0:...}}Input 2 of logic 1 Bit1.2 booleanCW
28Output B-{{0:...}}Scene1 Byte18.1 scene controlCW
28Output B-{{0:...}}Status (continuous),1 byte1 Byte5.1 percentage (0..100%)CRT
29Output B-{{0:...}}Change threshold 11 Byte5.10 counter pulses (0..255)CW
29Output B-{{0:...}}Continuous control1 Byte5.1 percentage (0..100%)CW
30Output B-{{0:...}}Threshold input 1 Byte5.10 counter pulses (0..255)CW
31Output B-{{0:...}}Forced operation1 Bit1.1 switchCW
31Output B-{{0:...}}Forced operation2 Bit2.1 switch controlCW
31Output B-{{0:...}}Forced operation1 Bit1.3 enableCW
32Output C-{{0:...}}Switch status1 Bit1.1 switchCRT
33Output C-{{0:...}}Switch1 Bit1.1 switchCW
33Output C-{{0:...}}On-Off1 Bit1.1 switchCW
34Output C-{{0:...}}Switch out with delay1 Bit1.1 switchCW
34Output C-{{0:...}}Switch out with flashing1 Bit1.1 switchCW
34Output C-{{0:...}}Output of staircase lighting1 Bit1.1 switchCW
34Output C-{{0:...}}Status (continuous),1 bit 1 Bit1.1 switchCRT
35Output C-{{0:...}}Switch time function1 Bit1.3 enableCW
36Output C-{{0:...}}Warning of staircase 1 Bit1.5 alarmCT
36Output C-{{0:...}}Report fault1 Bit1.5 alarmCRT
37Output C-{{0:...}}Duration of staircase 2 Bytes7.5 time (s)CRW
38Output C-{{0:...}}Recall preset1 Bit1.22 sceneCW
39Output C-{{0:...}}Store preset1 Bit1.22 sceneCW
39Output C-{{0:...}}Trigger switch regularly 1 Bit1.3 enableCW
40Output C-{{0:...}}Input 1 of logic 1 Bit1.2 booleanCW
41Output C-{{0:...}}Input 2 of logic 1 Bit1.2 booleanCW
42Output C-{{0:...}}Scene1 Byte18.1 scene controlCW
42Output C-{{0:...}}Status (continuous),1 byte1 Byte5.1 percentage (0..100%)CRT
43Output C-{{0:...}}Change threshold 11 Byte5.10 counter pulses (0..255)CW
43Output C-{{0:...}}Continuous control1 Byte5.1 percentage (0..100%)CW
44Output C-{{0:...}}Threshold input 1 Byte5.10 counter pulses (0..255)CW
45Output C-{{0:...}}Forced operation1 Bit1.1 switchCW
45Output C-{{0:...}}Forced operation2 Bit2.1 switch controlCW
45Output C-{{0:...}}Forced operation1 Bit1.3 enableCW
46Output D-{{0:...}}Switch status1 Bit1.1 switchCRT
47Output D-{{0:...}}Switch1 Bit1.1 switchCW
47Output D-{{0:...}}On-Off1 Bit1.1 switchCW
48Output D-{{0:...}}Switch out with delay1 Bit1.1 switchCW
48Output D-{{0:...}}Switch out with flashing1 Bit1.1 switchCW
48Output D-{{0:...}}Output of staircase lighting1 Bit1.1 switchCW
48Output D-{{0:...}}Status (continuous),1 bit 1 Bit1.1 switchCRT
49Output D-{{0:...}}Switch time function1 Bit1.3 enableCW
50Output D-{{0:...}}Warning of staircase 1 Bit1.5 alarmCT
50Output D-{{0:...}}Report fault1 Bit1.5 alarmCRT
51Output D-{{0:...}}Duration of staircase 2 Bytes7.5 time (s)CRW
52Output D-{{0:...}}Recall preset1 Bit1.22 sceneCW
53Output D-{{0:...}}Store preset1 Bit1.22 sceneCW
53Output D-{{0:...}}Trigger switch regularly 1 Bit1.3 enableCW
54Output D-{{0:...}}Input 1 of logic 1 Bit1.2 booleanCW
55Output D-{{0:...}}Input 2 of logic 1 Bit1.2 booleanCW
56Output D-{{0:...}}Scene1 Byte18.1 scene controlCW
56Output D-{{0:...}}Status (continuous),1 byte1 Byte5.1 percentage (0..100%)CRT
57Output D-{{0:...}}Change threshold 11 Byte5.10 counter pulses (0..255)CW
57Output D-{{0:...}}Continuous control1 Byte5.1 percentage (0..100%)CW
58Output D-{{0:...}}Threshold input 1 Byte5.10 counter pulses (0..255)CW
59Output D-{{0:...}}Forced operation1 Bit1.1 switchCW
59Output D-{{0:...}}Forced operation2 Bit2.1 switch controlCW
59Output D-{{0:...}}Forced operation1 Bit1.3 enableCW
172Total currentTotal active energy(Wh)4 Bytes13.10 active energy (Wh)CRWT
172Total currentTotal active energy(kWh)4 Bytes13.13 active energy (kWh)CRWT
173Total currentValue of total current(A)4 Bytes14.19 electric current (A)CRT
173Total currentValue of total current(kW)2 Bytes9.24 power (kW)CRT
173Total currentValue of total current(mA)2 Bytes7.12 current (mA)CRT
173Total currentValue of total current(mA)2 Bytes9.21 current (mA)CRT
174Total currentExceedance of total load1 Bit1.1 switchCRWT
175Output A-{{0:...}}Current value(mA)2 Bytes7.12 current (mA)CRT
175Output A-{{0:...}}Current value(mA)2 Bytes9.21 current (mA)CRT
175Output A-{{0:...}}Current value(A)4 Bytes14.19 electric current (A)CRT
175Output A-{{0:...}}Current value(kW)2 Bytes9.24 power (kW)CRT
176Output A-{{0:...}}Exceedance of load 1 Bit1.1 switchCRT
177Output A-{{0:...}}Lower deviation of load1 Bit1.1 switchCRT
178Output A-{{0:...}}Switch counter2 Bytes7.1 pulsesCRWT
178Output A-{{0:...}}Switch counter4 Bytes12.1 counter pulses (unsigned)CRWT
179Output A-{{0:...}}Operation hours2 Bytes7.7 time (h)CRWT
179Output A-{{0:...}}Operation hours4 Bytes13.100 time lag (s)CRWT
180Output A-{{0:...}}Active energy(Wh)4 Bytes13.10 active energy (Wh)CRWT
180Output A-{{0:...}}Active energy(kWh)4 Bytes13.13 active energy (kWh)CRWT
181Output B-{{0:...}}Current value(mA)2 Bytes7.12 current (mA)CRT
181Output B-{{0:...}}Current value(mA)2 Bytes9.21 current (mA)CRT
181Output B-{{0:...}}Current value(A)4 Bytes14.19 electric current (A)CRT
181Output B-{{0:...}}Current value(kW)2 Bytes9.24 power (kW)CRT
182Output B-{{0:...}}Exceedance of load 1 Bit1.1 switchCRT
183Output B-{{0:...}}Lower deviation of load1 Bit1.1 switchCRT
184Output B-{{0:...}}Switch counter2 Bytes7.1 pulsesCRWT
184Output B-{{0:...}}Switch counter4 Bytes12.1 counter pulses (unsigned)CRWT
185Output B-{{0:...}}Operation hours2 Bytes7.7 time (h)CRWT
185Output B-{{0:...}}Operation hours4 Bytes13.100 time lag (s)CRWT
186Output B-{{0:...}}Active energy(Wh)4 Bytes13.10 active energy (Wh)CRWT
186Output B-{{0:...}}Active energy(kWh)4 Bytes13.13 active energy (kWh)CRWT
187Output C-{{0:...}}Current value(mA)2 Bytes7.12 current (mA)CRT
187Output C-{{0:...}}Current value(mA)2 Bytes9.21 current (mA)CRT
187Output C-{{0:...}}Current value(A)4 Bytes14.19 electric current (A)CRT
187Output C-{{0:...}}Current value(kW)2 Bytes9.24 power (kW)CRT
188Output C-{{0:...}}Exceedance of load 1 Bit1.1 switchCRT
189Output C-{{0:...}}Lower deviation of load1 Bit1.1 switchCRT
190Output C-{{0:...}}Switch counter2 Bytes7.1 pulsesCRWT
190Output C-{{0:...}}Switch counter4 Bytes12.1 counter pulses (unsigned)CRWT
191Output C-{{0:...}}Operation hours2 Bytes7.7 time (h)CRWT
191Output C-{{0:...}}Operation hours4 Bytes13.100 time lag (s)CRWT
192Output C-{{0:...}}Active energy(Wh)4 Bytes13.10 active energy (Wh)CRWT
192Output C-{{0:...}}Active energy(kWh)4 Bytes13.13 active energy (kWh)CRWT
193Output D-{{0:...}}Current value(mA)2 Bytes7.12 current (mA)CRT
193Output D-{{0:...}}Current value(mA)2 Bytes9.21 current (mA)CRT
193Output D-{{0:...}}Current value(A)4 Bytes14.19 electric current (A)CRT
193Output D-{{0:...}}Current value(kW)2 Bytes9.24 power (kW)CRT
194Output D-{{0:...}}Exceedance of load 1 Bit1.1 switchCRT
195Output D-{{0:...}}Lower deviation of load1 Bit1.1 switchCRT
196Output D-{{0:...}}Switch counter2 Bytes7.1 pulsesCRWT
196Output D-{{0:...}}Switch counter4 Bytes12.1 counter pulses (unsigned)CRWT
197Output D-{{0:...}}Operation hours2 Bytes7.7 time (h)CRWT
197Output D-{{0:...}}Operation hours4 Bytes13.100 time lag (s)CRWT
198Output D-{{0:...}}Active energy(Wh)4 Bytes13.10 active energy (Wh)CRWT
198Output D-{{0:...}}Active energy(kWh)4 Bytes13.13 active energy (kWh)CRWT
Parameters (126)
ParameterTypeDefault
Product typelist4-Fold Output
Relay drive typelistInverted(apply to Ver.2)
Operation delay after bus recovery [10…250]unsignedInt 10…25010
Sending cycle of "In operation" telegram [1..240,0=inactive]unsignedInt 0…2400
Total currentunsignedInt 0…10
Enable safety priority functionunsignedInt 0…10
Safety priority 1listInactive
Control period of safety priority 1 [1..240,0=inactive]unsignedInt 0…2400
Safety priority 2listInactive
Control period of safety priority 2 [1..240,0=inactive]unsignedInt 0…2400
Priority of safety operationlistPriority of 2 is higher than that of 1
Normal, object value of switch on/offlist"1"=switch on; "0"=switch off
Object selection for the current measurementlistValue in mA(DPT 7.012)
Factor for conversion into theoretical wattage kW: Current value x FactorunsignedInt 100…250230
Send current value after changes valuelistInactive
Cyclic sendlistInactive
Monitoring exceedance of loadunsignedInt 0…10
Factor for load monitoring [1..200]unsignedInt 1…2001
Hysteresis [10..100]unsignedInt 10…10010
Behavior at exceedinglistSend no telegram
Behavior at not exceedinglistSend no telegram
Send exceeding cyclicallistInactive
Total power meter function(Wh/kWh)unsignedInt 0…10
Object selection for power meterlistValue in Wh(DPT 13.010)
Sending object valuelistOnly request
Memory of all current detecting delete after download of applicationunsignedInt 0…10
Work mode of the channel islistSwitch actuator
If bus recovery,output status islistUnchange
If bus failure,output status islistUnchange
Obj. value of "switch" after bus recoverylistTo write with "0"
Set the reply mode of switch statuslistTransmit after change
Object value of switch statuslist0=contact open ; 1=contact close
Output status for the telegram "1" (telegram "0" is opposite of selection)listContact close
Extension functionunsignedInt 0…10
Valve typelistNormal (de-energised closed)
If bus recovery, valve position islist0%(OFF)
PWM cycle time for continuous control [1...240]unsignedInt 1…2403
PWM cycle time for continuous control [0...59]unsignedInt 0…590
Control typelist1 bit ( on-off control )
Reply the status of channel for continuous controllistNothing
Reply the status of contact statelistNothing
Function of "Time"unsignedInt 0…10
Function of "Preset"unsignedInt 0…10
Function of "Logic"unsignedInt 0…10
Function of "Scene"unsignedInt 0…10
Function of "Threshold"unsignedInt 0…10
Function of "Safety"unsignedInt 0…10
Function of "Forced"unsignedInt 0…10
Function of "Current" for switchunsignedInt 0…10
The mode of time functionlistDelay switch
Delay for switch on(contact close) --(0...240 minutes)unsignedInt 0…2400
--(0...59 seconds)unsignedInt 0…590
Delay for switch off(contact open) --(0...240 minutes)unsignedInt 0…2400
Duration of switch on(contact colose) --(0...240 minutes)unsignedInt 0…2400
Duration of switch off(contact open) --(0...240 minutes)unsignedInt 0…2400
Number of ON-impulses [1..255,0=no limited]unsignedInt 0…2550
Output status after flashinglistUnchange
Control mode of flashinglistStart with "1" , Stop with "0"
Duration of staircase lighting --(0...1000 minutes)unsignedInt 0…10002
Control mode of staircase lightinglistStart with "0/1" , can not be stop
During the lighting time, if receive the "Start" telegramlistRestart duration of staircase lighting
Warning mode for ending of staircase lightinglistNothing
--The warning time for end of staircase lighting [0..59]unsignedInt 0…590
Modify the duration via object[0..60059s]unsignedInt 0…10
Output status of the telegram "0"listNone
Output status of the telegram "1"listContact open
Preset can be changed via busunsignedInt 0…10
The input 0 (switch object) for logicunsignedInt 0…10
The input 1 of logicunsignedInt 0…10
Function type between input0 and input1listAND
Invert result(if no,"1"=contact close,"0"=contact open;while yes is opposite)unsignedInt 0…10
Value of input 1 after bus recoverylist"0"
The input 2 of logicunsignedInt 0…10
Function type between input2 and input0/1listAND
Value of input 2 after bus recoverylist"0"
1> channel is assigned to (1..64,0=no allocation)unsignedInt 0…640
--Output status islistContact open
2> channel is assigned to (1..64,0=no allocation)unsignedInt 0…640
3> channel is assigned to (1..64,0=no allocation)unsignedInt 0…640
4> channel is assigned to (1..64,0=no allocation)unsignedInt 0…640
5> channel is assigned to (1..64,0=no allocation)unsignedInt 0…640
6> channel is assigned to (1..64,0=no allocation)unsignedInt 0…640
7> channel is assigned to (1..64,0=no allocation)unsignedInt 0…640
8> channel is assigned to (1..64,0=no allocation)unsignedInt 0…640
Threshold 1 valueunsignedInt 0…25580
Threshold 2 valueunsignedInt 0…255200
Threshold 1 can be changed via busunsignedInt 0…10
Threshold behaviourlistWithout hysteresis
If falling below lower threshold, output status islistUnchange
If exceeding upper threshold, output status islistUnchange
If between lower and upper threshold, output status islistUnchange
Setting of safetylistOn parameter-window "General"
Output status if safety priority 1listUnchange
Output status if safety priority 2listUnchange
Forced operation typelist1bit
Output status if forced operationlistUnchange
Load typelistResistive
Current correction [-1000..1000]signedInt -1000…10000
Power meter function(Wh/kWh)unsignedInt 0…10
Object of current measurementlistValue in mA(DPT 7.012)
Add the channel to total current valueunsignedInt 0…10
Value range for load monitoringlist100 mA - 20 A
Monitoring lower deviation of loadunsignedInt 0…10
Behavior at deviatinglistSend no telegram
Behavior at not deviatinglistSend no telegram
Send falling below cyclicallistInactive
Counter functionunsignedInt 0…10
Object of switch and operation hours counterlist4 byte Value
Switch count iflistContact close
Hours count iflistContact close
Send counter value in hours [0..100]unsignedInt 0…1000
Function of monitoringunsignedInt 0…10
Function of forced operationunsignedInt 0…10
Function of regular switchunsignedInt 0…10
Function of safety operationunsignedInt 0…10
Cyclic monitoring control value --in minutes (0...240 minutes)unsignedInt 0…24060
--in seconds (0...59 seconds)unsignedInt 0…590
Valve position during faultlistUnchange
Report fault statusunsignedInt 0…10
Valve position during forced operationlistUnchange
Time of switch regular in [0..255]unsignedInt 0…25510
Automatic switch regularlylistDisable
Valve position during safety 1 operationlistUnchange
Valve position during safety 2 operationlistUnchange
Description (max.30 char.)text
Overwrite scene stored values during downloadunsignedInt 0…11

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch Actuator with Secure, 4-Fold/3.0 3.0 latest$0085A90E2026-11-25182 KBDownload

About this file

This is the official ETS product database for the GVS Switch Actuator with Secure, 4-Fold (ARSA-04/xx.S), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.