GVS · Order number 1A10xxA01R · Actuator › Switch

Download .knxprod Switch Actuator, 4-Fold 2.1 · 154 KB

Product

ManufacturerGVS
Product nameKA/R 0416.2, KA/R 0420.1
Order number1A10xxA01R
Product textSwitch Actuator, 4-Fold
HardwareKA/R 0416.1
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
RegistrationCertified
Languagesde-DE, en-US, zh-CN, it-IT
Catalog entryM-0085_H-10AA01-1_HP-0005-21-30F2_CI-1A10xxA01R-1
Fingerprint30F2
SHA-256542ef50de45688f461f04419e363926ab8d137af37936aa41e9e55c61fa10bbb
First seen2026-11-25
Markets69 markets

Application program: Switch Actuator, 4-Fold 2.1

Application number$0005
Version2.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters457
Group objects103
Group objects (103)
NoNameFunctionSizeDPTFlags
0GeneralIn operation1 Bit1.1 switchCRT
1GeneralSafety priority 11 Bit1.5 alarmCWU
2GeneralSafety priority 21 Bit1.5 alarmCWU
3Output AReply the switch status, A1 Bit1.1 switchCRT
3Output ASend the switch status, A1 Bit1.1 switchCRT
3Output AReply status of contact , A1 Bit1.1 switchCRT
4Output ASwitch, A1 Bit1.1 switchCW
4Output AOn-off of regulating , A1 Bit1.1 switchCW
5Output ASwitch out with delay, A1 Bit1.1 switchCW
5Output ASwitch out with flashing, A1 Bit1.10 start/stopCW
5Output AOutput of staircase lighting,A1 Bit1.10 start/stopCW
5Output AStatus (continuous),1 bit, A1 Bit1.1 switchCRT
6Output ASwitch time function, A1 Bit1.3 enableCW
7Output AWarning of staircase , A1 Bit1.5 alarmCRT
7Output AReport fault, regulating , A1 Bit1.5 alarmCRT
8Output ADuration of staircase , A2 Bytes7.1 pulsesCRW
9Output ACall preset 1/2 , A1 Bit1.22 sceneCW
10Output AStore preset 1/2, A1 Bit1.22 sceneCW
10Output ATrigger switch regularly , A1 Bit1.1 switchCW
11Output AInput 1 of logic , A1 Bit1.2 booleanCW
12Output AInput 2 of logic , A1 Bit1.2 booleanCW
13Output AScene handle, A1 Byte18.1 scene controlCW
13Output AStatus (continuous),1 byte, A1 Byte5.1 percentage (0..100%)CRT
14Output AChange threshold 1, A1 Byte5.10 counter pulses (0..255)CW
14Output AContinuous of regulating , A1 Byte5.1 percentage (0..100%)CW
15Output AThreshold input , A1 Byte5.10 counter pulses (0..255)CW
16Output AForced output , A1 Bit1.3 enableCW
16Output AForced operation,regulating, A1 Bit1.3 enableCW
17Output BReply the switch status, B1 Bit1.1 switchCRT
17Output BSend the switch status, B1 Bit1.1 switchCRT
17Output BReply status of contact , B1 Bit1.1 switchCRT
18Output BSwitch, B1 Bit1.1 switchCW
18Output BOn-off of regulating , B1 Bit1.1 switchCW
19Output BSwitch out with delay, B1 Bit1.1 switchCW
19Output BOutput of staircase lighting,B1 Bit1.10 start/stopCW
19Output BSwitch out with flashing, B1 Bit1.10 start/stopCW
19Output BStatus (continuous),1 bit, B1 Bit1.1 switchCRT
20Output BSwitch time function, B1 Bit1.3 enableCW
21Output BWarning of staircase , B1 Bit1.5 alarmCRT
21Output BReport fault, regulating , B1 Bit1.5 alarmCRT
22Output BDuration of staircase , B2 Bytes7.1 pulsesCRW
23Output BCall preset 1/2 , B1 Bit1.22 sceneCW
24Output BStore preset 1/2, B1 Bit1.22 sceneCW
24Output BTrigger switch regularly , B1 Bit1.1 switchCW
25Output BInput 1 of logic , B1 Bit1.2 booleanCW
26Output BInput 2 of logic , B1 Bit1.2 booleanCW
27Output BScene handle, B1 Byte18.1 scene controlCW
27Output BStatus (continuous),1 byte, B1 Byte5.1 percentage (0..100%)CRT
28Output BChange threshold 1, B1 Byte5.10 counter pulses (0..255)CW
28Output BContinuous of regulating , B1 Byte5.1 percentage (0..100%)CW
29Output BThreshold input , B1 Byte5.10 counter pulses (0..255)CW
30Output BForced output , B1 Bit1.3 enableCW
30Output BForced operation,regulating, B1 Bit1.3 enableCW
31Output CReply the switch status, C1 Bit1.1 switchCRT
31Output CSend the switch status, C1 Bit1.1 switchCRT
31Output CReply status of contact , C1 Bit1.1 switchCRT
32Output CSwitch, C1 Bit1.1 switchCW
32Output COn-off of regulating , C1 Bit1.1 switchCW
33Output CSwitch out with delay, C1 Bit1.1 switchCW
33Output COutput of staircase lighting,C1 Bit1.10 start/stopCW
33Output CSwitch out with flashing, C1 Bit1.10 start/stopCW
33Output CStatus (continuous),1 bit, C1 Bit1.1 switchCRT
34Output CSwitch time function, C1 Bit1.3 enableCW
35Output CWarning of staircase , C1 Bit1.5 alarmCRT
35Output CReport fault, regulating , C1 Bit1.5 alarmCRT
36Output CDuration of staircase , C2 Bytes7.1 pulsesCRW
37Output CCall preset 1/2 , C1 Bit1.22 sceneCW
38Output CStore preset 1/2, C1 Bit1.22 sceneCW
38Output CTrigger switch regularly , C1 Bit1.1 switchCW
39Output CInput 1 of logic , C1 Bit1.2 booleanCW
40Output CInput 2 of logic , C1 Bit1.2 booleanCW
41Output CScene handle, C1 Byte18.1 scene controlCW
41Output CStatus (continuous),1 byte, C1 Byte5.1 percentage (0..100%)CRT
42Output CChange threshold 1, C1 Byte5.10 counter pulses (0..255)CW
42Output CContinuous of regulating , C1 Byte5.1 percentage (0..100%)CW
43Output CThreshold input , C1 Byte5.10 counter pulses (0..255)CW
44Output CForced output , C1 Bit1.3 enableCW
44Output CForced operation,regulating, C1 Bit1.3 enableCW
45Output DReply the switch status, D1 Bit1.1 switchCRT
45Output DSend the switch status, D1 Bit1.1 switchCRT
45Output DReply status of contact , D1 Bit1.1 switchCRT
46Output DSwitch, D1 Bit1.1 switchCW
46Output DOn-off of regulating , D1 Bit1.1 switchCW
47Output DSwitch out with delay, D1 Bit1.1 switchCW
47Output DOutput of staircase lighting,D1 Bit1.10 start/stopCW
47Output DSwitch out with flashing, D1 Bit1.10 start/stopCW
47Output DStatus (continuous),1 bit, D1 Bit1.1 switchCRT
48Output DSwitch time function, D1 Bit1.3 enableCW
49Output DWarning of staircase , D1 Bit1.5 alarmCRT
49Output DReport fault, regulating , D1 Bit1.5 alarmCRT
50Output DDuration of staircase , D2 Bytes7.1 pulsesCRW
51Output DCall preset 1/2 , D1 Bit1.22 sceneCW
52Output DStore preset 1/2, D1 Bit1.22 sceneCW
52Output CTrigger switch regularly , D1 Bit1.1 switchCW
53Output DInput 1 of logic , D1 Bit1.2 booleanCW
54Output DInput 2 of logic , D1 Bit1.2 booleanCW
55Output DScene handle, D1 Byte18.1 scene controlCW
55Output DStatus (continuous),1 byte, D1 Byte5.1 percentage (0..100%)CRT
56Output DChange threshold 1, D1 Byte5.10 counter pulses (0..255)CW
56Output DContinuous of regulating , D1 Byte5.1 percentage (0..100%)CW
57Output DThreshold input , D1 Byte5.10 counter pulses (0..255)CW
58Output DForced output , D1 Bit1.3 enableCW
58Output DForced operation,regulating, D1 Bit1.3 enableCW
Parameters (85)
ParameterTypeDefault
Operation delay after recovery of bus voltage(1...250s)unsignedInt 1…2501
Sending cycle of In operation telegram (1......240s , 0=inactive)unsignedInt 0…2400
Enable safety priority functionlistdisable
---set safety priority 1:listinactive
Control period of safety priority 1 (1......240 s, 0=inactive)unsignedInt 0…2400
---set safety priority 2:listinactive
Control period of safety priority 2 (1......240 s, 0=inactive)unsignedInt 0…2400
=====N o t e===== Normal, object value map switch on/offlist1=switch on; 0=switch off
Work mode of the channellistSwitch actuator
If bus voltage recovery,contact islistunchange
If bus voltage fail,contact islistunchange
Object value of telegram switch after bus voltage recoverylistnot write
Set the reply mode of switch statuslistno reply
Object value of switch status :list0=contact open ; 1=contact close
Contact position if tele. value is 1 (0 is opposite of 1 if changed)listclose
Special functions of switch actuator modelistinactive
Function of time for switch islistdisable
Function of preset for switch islistdisable
Function of logic for switch islistdisable
Function of scene for switch islistdisable
Function of threshold for switch islistdisable
Function of safety for switch islistdisable
Function of forced for switch islistdisable
The mode of time functionlistdelay switch
Delay for switch on : --(0...240 minutes)unsignedInt 0…2400
--(0...59 seconds)unsignedInt 0…590
Delay for switch off : --(0...240 minutes)unsignedInt 0…2400
Number of ON-impulses (1...255 , 0=no limited)unsignedInt 0…2550
Contact position after flashinglistunchange
The mode of control for flashinglistStart with 1 , Stop with 0"
Duration of staircase lighting --(0...1000 minutes)unsignedInt 0…10002
The mode of control for staircase lighting islistStart with 0/1 , can not be stop
During the lighting time, if receive the Start telegram,listrestart duration of staircase lighting
Warning mode for ending of staircase lightinglistnothing
--The warning time for end of staircase lighting(0...59 s)unsignedInt 0…590
Modify the duration via object (0...60059 seconds)listdisable
Action for preset 1(object value=0)listNone
Action for preset 2(object value=1)listOFF
Setting for preset via telegram islistdisable
The input 0 (switch object) for logic islistdisable
The input 1 of logic islistdisable
Function type between input0 and input1listAND
Result is invertedlistNO
Value of input 1 after bus voltage recovery :list0"
The input 2 of logic islistdisable
Function type between input2 and input0/1listAND
Value of input 2 after bus voltage recovery :list0"
1> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
--Standard output value islistOFF
2> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
3> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
4> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
5> channel is assigned to (1...64 scene NO.,0= no allocation)unsignedInt 0…640
Threshold 1 valueunsignedInt 0…25580
Threshold 2 valueunsignedInt 0…255200
Change threshold 1via object :listdisable
Threshold behaviourlistwithout hysteresis
--If falling below lower threshold, contact positionlistunchange
--If exceeding upper threshold, contact positionlistunchange
--If lower < object value < upper contact positionlistunchange
Setting of safetyliston parameter-window General"
Contact position if safety priority 1listunchange
Contact position if safety priority 2listunchange
Contact position if forced operationlistunchange
If bus voltage fail ,contact islistunchange
If bus voltage recovery, the duty cycle of dynamic regulatelist0%(OFF)
PWM cycle time for continuous control (1...240 minutes)unsignedInt 0…2403
PWM cycle time for continuous control (0...59 secondsunsignedInt 0…590
Control telegram is received aslist1 bit ( on-off control )
Reply the status of channel for continuous controllistnothing
Reply the status of contact statelistnothing
Special functions of dynamic regulating actuator modelistinactive
Function for monitoring islistdisable
Function of forced operation islistdisable
Function of regular switch islistdisable
Function of safety operation islistdisable
Cyclic monitoring --in minutes (0...240 minutes)unsignedInt 0…24060
--in seconds (0...59 seconds)unsignedInt 0…590
The duty cycle of dynamic regulating during faultlistunchange
sending object report fault islistdisable
The duty cycle of dynamic regulating during forced operationlistunchange
Time of switch regular in minutes (0..255)unsignedInt 0…25510
Automatic switch regularlylistdisable
The duty cycle of dynamic regulating during safety 1 operationlistunchange
The duty cycle of dynamic regulating during safety 2 operationlistunchange

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch Actuator, 4-Fold 2.1 latest$000530F22026-11-25154 KBDownload

About this file

This is the official ETS product database for the GVS KA/R 0416.2, KA/R 0420.1 (1A10xxA01R), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.