KNX Database
GVS 1A02XXB02D KA/D 0203.1、KA/D 0215.S.1

KA/D 0203.1、KA/D 0215.S.1 1A02XXB02D

GVS · Order number 1A02XXB02D · Actuator › Dimmer

Dimming Actuator, 2-Fold, 230V AC

Download .knxprod Dimming Actuator, 2-Fold 1.0 · 139 KB

Product

ManufacturerGVS
Product nameKA/D 0203.1、KA/D 0215.S.1
Order number1A02XXB02D
Product textDimming Actuator, 2-Fold
HardwareKA/D 0203.1
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
RegistrationCertified
Languagesde-DE, fr-FR, en-US, zh-CN
Catalog entryM-0085_H-10AB02-1_HP-0112-10-20C3_CI-1A02XXB02D-1
Fingerprint20C3
SHA-2560c3b471d529829dadb963e5f6f486693268619df90da88ed1c600509f646c2ca
First seen2026-11-25
Markets69 markets

Application program: Dimming Actuator, 2-Fold 1.0

Application number$0112
Version1.0
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters254
Group objects24
Group objects (24)
NoNameFunctionSizeDPTFlags
0OUTPUT ASwitch A1 Bit1.1 switchCW
1OUTPUT ASwitch status A1 Bit1.1 switchCRT
2OUTPUT ARelative dimming A4 Bit3.7 dimming controlCW
3OUTPUT ABrightness A1 Byte5.1 percentage (0..100%)CW
4OUTPUT ABrightness status A1 Byte5.1 percentage (0..100%)CRT
5OUTPUT APermanent on A1 Bit1.1 switchCW
6OUTPUT AScene / save A1 Byte18.1 scene controlCW
7OUTPUT AA Preset 11 Bit1.22 sceneCW
8OUTPUT ASet preset 11 Bit1.22 sceneCW
9OUTPUT AA Preset 21 Bit1.22 sceneCW
10OUTPUT ASet preset 21 Bit1.22 sceneCW
11OUTPUT BSwitch B1 Bit1.1 switchCW
12OUTPUT BSwitch status B1 Bit1.1 switchCRT
13OUTPUT BRelative dimming B4 Bit3.7 dimming controlCW
14OUTPUT BBrightness B1 Byte5.1 percentage (0..100%)CW
15OUTPUT BBrightness status B1 Byte5.1 percentage (0..100%)CRT
16OUTPUT BPermanent on B1 Bit1.1 switchCW
17OUTPUT BScene / save B1 Byte18.1 scene controlCW
18OUTPUT BB Preset 11 Bit1.22 sceneCW
19OUTPUT BSet preset 11 Bit1.22 sceneCW
20OUTPUT BB Preset 21 Bit1.22 sceneCW
21OUTPUT BSet preset 21 Bit1.22 sceneCW
22Error reportReport error of deivce1 ByteCRT
23In operateIn operate1 Bit1.1 switchCT
Parameters (88)
ParameterTypeDefault
Telegram ratelistNo limit
Error reportlistDisable
Sending cycle time in s[1..65535]unsignedInt 1…6553560
Send object "In operation"listno
Channel functionlistDeactive
Staircase lightinglistDeactive
Brightness value OBJ transmit after dimminglistNothing
Switch Status reportlistNothing
Time duration of dimming Time = entry * 2unsignedInt 0…2552
Switch on via OBJ switch withlistPreset brightness value
Preset switch on brightness (1%~100%)unsignedInt 1…100100
Reaction on receipt of switch on valuelistSwitch on softly
Reaction on receipt brightness valuelistDimming on
Switch-OFF modelistSwitch off softly
After bus recover switch on withlistLast brightness
Bus recover preset brightness value (0%~100%)unsignedInt 0…1000
Status report after telegram to OBJ "switch"listTransmit only after change
Relative dimminglist
Low dimming threshold 1~127(0.4%~49.9%)unsignedInt 1…1271
Upper dimming threshold 128~255(50.2%~100%)unsignedInt 128…255255
If dimming down and value <= low dimming threhold output switchlistOff
Output switch on after receipt of dimming up telegramlistYes
Brightness valuelist
Upper dimming threshold 128~255(50.2%~100%)unsignedInt 128…255255
If output on: receipt of Brightness value = 0 output switchlistOff
On receipt Brightness Value>=1 output switch onlistYes
Scene function islistDisable
Scene selectlist1st Scene
Reaction on receipt scene 1listDimming on
Scene 1 duration (Time = entry *2S)unsignedInt 0…2551
Scene 1 brightness value(0%~100%)unsignedInt 0…100100
Assignment to Scene number 1......64listnot assignment
Reaction on receipt scene 2listDimming on
Scene 2 duration (Time = entry *2S)unsignedInt 0…2551
Scene 2 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 3listDimming on
Scene 3 duration (Time = entry *2S)unsignedInt 0…2551
Scene 3 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 4listDimming on
Scene 4 duration (Time = entry *2S)unsignedInt 0…2551
Scene 4 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 5listDimming on
Scene 5 duration (Time = entry *2S)unsignedInt 0…2551
Scene 5 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 6listDimming on
Scene 6 duration (Time = entry *2S)unsignedInt 0…2551
Scene 6 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 7listDimming on
Scene 7 duration (Time = entry *2S)unsignedInt 0…2551
Scene 7 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 8listDimming on
Scene 8 duration (Time = entry *2S)unsignedInt 0…2551
Scene 8 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 9listDimming on
Scene 9 duration (Time = entry *2S)unsignedInt 0…2551
Scene 9 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 10listDimming on
Scene 10 duration (Time = entry *2S)unsignedInt 0…2551
Scene 10 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 11listDimming on
Scene 11 duration (Time = entry *2S)unsignedInt 0…2551
Scene 11 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 12listDimming on
Scene 12 duration (Time = entry *2S)unsignedInt 0…2551
Scene 12 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 13listDimming on
Scene 13 duration (Time = entry *2S)unsignedInt 0…2551
Scene 13 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 14listDimming on
Scene 14 duration (Time = entry *2S)unsignedInt 0…2551
Scene 14 brightness value(0%~100%)unsignedInt 0…100100
Reaction on receipt scene 15listDimming on
Scene 15 duration (Time = entry *2S)unsignedInt 0…2551
Scene 15 brightness value(0%~100%)unsignedInt 0…100100
Active preset 1 via bus telegramlistDeactive
Brightness value islistDimming on
Brightness value at obj=0 (1%~100%)unsignedInt 1…100100
Brightness value at obj=1 (1%~100%)unsignedInt 1…100100
Preset 1 can be set via the buslistDisable
Active preset 2 via bus telegramlistDeactive
Preset 2 can be set via the buslistDisable
Duration of staircase lighting: Baselist1.0s
Duration of staircase lighting:Factor Factor(1~127) Duration = Base*FactorunsignedInt 1…1271
Time for dimming down to 20% (Duration = Entry*2 S)unsignedInt 0…2551
Brightness value for staircase lighting (20%~100%)unsignedInt 20…100100
Staircase lighting after bus voltage recoverylistSwitch off
Staircase value at permanent-on (20%~100%)unsignedInt 20…100100
On receiption switch OBJ = 0 switch off enablelistDisable

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Dimming Actuator, 2-Fold 1.0 latest$011220C32026-11-25139 KBDownload

About this file

This is the official ETS product database for the GVS KA/D 0203.1、KA/D 0215.S.1 (1A02XXB02D), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from GVS

All GVS products