| Konvertierbar ab Version 0.6 | unsignedInt 0…255 | 6 |
| Wird bei jedem Download auf 0xFF gesetzt
App. setzt es dann auf 0 | unsignedInt 0…255 | 255 |
| Time-delayed switching of drives | list | Deactivated |
| Falls Parent = inaktiv wird hier 0
runter geladen | unsignedInt 0…255 | 0 |
| Time delay in s [1...15] | unsignedInt 1…15 | 1 |
| Sending and switching delay after bus
voltage recovery in s [2...255] | unsignedInt 2…255 | 2 |
| During sending and switching delay
outputs remain unchanged. | list | <-- Note |
| Send object "In operation" | list | No |
| Sending cycle time
in s [1...65,535] | unsignedInt 1…65535 | 60 |
| Object value | list | 1 |
| Limit number of telegrams | list | No |
| Max. number of sent telegrams | unsignedInt 1…255 | 1 |
| In period | list | 1 s |
| Enable communication object
"Request status values" 1 bit | list | No |
| Request with object value | list | 1 |
| JA bei JRA/Sx.yyy.5.1
d.h. alle Geräte mit Handbedienung | list | No |
| Manual operation | list | Enabled |
| Manual operation after bus voltage
recovery, programming and reset | list | Enabled |
| Reset manual operat. to KNX operation | list | Automatically and via push button |
| Time for automatic reset
in s [10...6,000] | unsignedInt 10…6000 | 300 |
| Enable communication object
"Status Man. operation" 1 bit | list | No |
| Send object value | list | No, update only |
| Safety commands like weather alarms,
blocking and forced operation have | list | <-- Note |
| Parameter settings | list | Standard |
| Order of priority for weather alarm
functions | list | 1.Wind alarm - 2.Rain alarm - 3.Frost alarm |
| Communication object no. 1 for
wind alarm | list | Activated |
| Communication object no. 2 for
wind alarm | list | Deactivated |
| Communication object no. 3 for
wind alarm | list | Deactivated |
| Monitoring period wind alarm in s
[0...1,000] (0 = monitoring deact.) | unsignedInt 0…1000 | 0 |
| Communication object for rain alarm | list | Deactivated |
| Monitoring period rain alarm in s
[0...1,000] (0 = monitoring deact.) | unsignedInt 0…1000 | 0 |
| Communication object for frost alarm | list | Deactivated |
| Monitoring period frost alarm in s
[0...1,000] (0 = monitoring deact.) | unsignedInt 0…1000 | 0 |
| Wind, rain, and frost alarm are
active only if a position is set | list | <-- Note |
| Read activated weather alarm objects
after bus voltage recovery | list | No |
| Read flags must be set
in sending device! | list | <-- Note |
| Operation mode | list | Control with slat adjustment |
| To control venetian or vertical blinds
and other shading systems with slats | list | <-- Note |
| To control roller shutters, awnings
and other products without slats | list | <-- Note |
| Reaction on bus voltage failure | list | Stop |
| Reaction on bus voltage failure | list | Open/on |
| Reaction after bus voltage recovery | list | Stop |
| Reaction after bus voltage recovery | list | Open/on |
| Position Height in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 0 |
| Position Slat in % [0...100]
(0% = open; 100% = closed) | unsignedInt 0…100 | 0 |
| Reaction after programming
or after ETS reset | list | Stop |
| Reaction after programming
or after ETS reset | list | Open/on |
| Invert output | list | No |
| Staircase lighting function | list | Deactivated |
| Duration/opening time for staircase
lighting function in s [0...30,000] | unsignedInt 0…30000 | 60 |
| Output reacts on communication object
for wind alarm no. | list | 1 |
| Position on wind alarm | list | Activated - up |
| Position on wind alarm | list | Deactivated |
| Position Height in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 0 |
| Position Slat in % [0...100]
(0% = open; 100% = closed) | unsignedInt 0…100 | 0 |
| Position on rain alarm | list | Deactivated |
| Position for frost alarm | list | Deactivated |
| Block | list | Deactivated |
| Position during blocking | list | No reaction |
| Forced operation (1 bit/2 bit) | list | Deactivated |
| Position during forced operation | list | Open/on |
| Position on reset of weather alarm,
blocking and forced operation | list | No reaction |
| Position on reset of weather alarm,
blocking and forced operation | list | Open/on |
| Position will only be carried out
with inactive autom. sun protection | list | <-- Note |
| Order of priority for safety alarm
functions | list | 1.Weather alarm - 2.Block - 3.Forced operation |
| Disable automatic sun protection
on reset of safety function | list | No |
| Wind, rain, and frost alarm are active
if objects on page "Weather alarms" | list | <-- Note |
| Detect travel times (Up/Down) | list | No - set travel times |
| Enable travel detection | list | Automatically |
| Position after travel detection | list | No reaction, remain in upper end position |
| UP time in s [0...6,000] | unsignedInt 0…6000 | 60 |
| DOWN time in s [0...6,000] | unsignedInt 0…6000 | 60 |
| Disconnect output from power after | list | Total travel time + 10% Overflow |
| Enable communication object
"Trigger reference movement" 1 bit | list | No |
| Position after reference movement | list | No reaction, remain in reference position |
| Delete saved travel times after
Download | list | No |
| Pause on change in direct. in ms (see
technical data of drive!) 50...10,000 | unsignedInt 50…10000 | 500 |
| Delay times for drive | list | Standard |
| Diff. between start-up and coasting
delay: time in ms/4 [-128...127] | signedInt -128…127 | 0 |
| Minimum run time for drive
in ms [10...255] | unsignedInt 10…255 | 50 |
| Jalousie/Raffstore mit Arbeitsstellung | list | No |
| Lamellenstellung bei Ab-Fahrt
in % (0% = offen;100% = geschlossen | unsignedInt 0…255 | 0 |
| Determine times for slat | list | Via duration of slat adjustment (step) |
| Duration to turn slat from 0% - 100%
in ms [50...60,000] | unsignedInt 50…60000 | 1500 |
| Duration of slat adjustment
(step) in ms [50...1,000] | unsignedInt 50…1000 | 200 |
| Number of slat adjustments
(from 0% = open to 100% = closed) | unsignedInt 1…60 | 7 |
| Quotient of slat adjustment time and
number of slat adj.: >= 50 ms! | list | <-- Note |
| Limit step commands to
number of slat adjustments | list | Yes |
| Total turning of slats after move DOWN | list | No |
| Position of slat after arriving on
lower end position (100% = disabled) | unsignedInt 0…100 | 100 |
| Limit travelling range | list | No |
| Upper limit in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 0 |
| Upper limit valid for
automatic commands | list | No |
| Upper limit valid for
direct commands | list | No |
| Lower limit in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 100 |
| Lower limit valid for
automatic commands | list | No |
| Lower limit valid for
direct commands | list | No |
| Set dead times | list | Standard |
| Dead time blinds/shutter from bottom
until moving up in ms [0...5,000] | unsignedInt 0…5000 | 0 |
| Dead time of slat from 100% closed
until slat turn in ms [0...5,000] | unsignedInt 0…5000 | 0 |
| Slippage of blinds/shutter on change
of direction in ms [0...5,000] | unsignedInt 0…5000 | 0 |
| Slippage of slat on change of
direction in ms [0...5,000] | unsignedInt 0…5000 | 0 |
| Tensioning blinds/shutter
or slot positioning | list | No |
| Time for tensioning/slot positioning
in ms [0...5,000] | unsignedInt 0…5000 | 0 |
| Enable positions/presets | list | No |
| Enable automatic sun protection | list | No |
| Enable 8 bit scene | list | No |
| Enable communication object
"Move to pos. height 0..255" | list | No |
| Enable communication objects
"Move to pos. height/Move slat 0..255" | list | No |
| Enable communication objects
"Move to/set position 1-4" 1 bit | list | No |
| Overwrite position values (presets)
during download | list | Yes |
| Enable communication object
"Status Open-Closed/On-Off" 1 bit | list | No |
| Position 1: Height in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 20 |
| Position 1: Slat in % [0...100]
(0% = open; 100% = closed) | unsignedInt 0…100 | 20 |
| Position 2: Height in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 40 |
| Enable communication object
"Status Operability" 1 bit | list | No |
| Position 2: Slat in % [0...100]
(0% = open; 100% = closed) | unsignedInt 0…100 | 40 |
| Position 3: Height in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 60 |
| Enable communication object
"Status information" 16 bit | list | No |
| Position 3: Slat in % [0...100]
(0% = open; 100% = closed) | unsignedInt 0…100 | 60 |
| Position 4: Height in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 80 |
| Position 4: Slat in % [0...100]
(0% = open; 100% = closed) | unsignedInt 0…100 | 80 |
| Move to position | list | Directly |
| Deactivation of automatic control | list | Via object "Activation" and move command |
| Automatic reactivation of
automatic control | list | Deactivated |
| Time to reactivate autom. control
automatically in min. [10...6,000] | unsignedInt 10…6000 | 300 |
| Toggling to automatic control | list | Enabled |
| Toggling to direct control | list | Enabled |
| Position for sun = 1 (sun) | list | Down |
| Position for sun = 0 (no sun) | list | Up |
| Delay for sun = 1 in s [0...6,000] | unsignedInt 0…6000 | 0 |
| Delay for sun = 0 in s [0...6,000] | unsignedInt 0…6000 | 0 |
| Read activated automatic objects
after bus voltage recovery | list | No |
| Read flags must be set at
sending device | list | <-- Note |
| Enable automatic heating/cooling | list | No |
| Delay for presence = 1
in s [0...6,000] | unsignedInt 0…6000 | 0 |
| Delay for presence = 0
in s [0...6,000] | unsignedInt 0…6000 | 0 |
| Position for heating = 1 and sun = 1 | list | Up |
| Use overheat control | list | No |
| Upper threshold value
room temperature in °C [21...50] | unsignedInt 21…50 | 24 |
| Position at upper threshold value
and sun = 1 | list | Down |
| Position Height in % [0...100]
(0% = top; 100% = bottom) | unsignedInt 0…100 | 0 |
| Position Slat in % [0...100]
(0% = open; 100% = closed) | unsignedInt 0…100 | 0 |
| Position for heating = 1 and sun = 0 | list | No reaction |
| Position for cooling = 1 and sun = 1 | list | Down |
| Position for cooling = 1 and sun = 0 | list | No reaction |
| On heating = 1 and cooling = 1 or
on heating = 0 and cooling = 0 | list | <-- Note |
| A: Scene | list | Deactivated |
| Overwrite scenes on download | list | No |
| Use 1st assignment | list | No |
| Assignment to scene number 1...64 | list | Scene No. 1 |
| Use 2nd assignment | list | No |
| Use 3rd assignment | list | No |
| Use 4th assignment | list | No |
| Use 5th assignment | list | No |
| Use 6th assignment | list | No |
| Use 7th assignment | list | No |
| Use 8th assignment | list | No |
| Use 9th assignment | list | No |
| Use 10th assignment | list | No |
| Use 11th assignment | list | No |
| Use 12th assignment | list | No |
| Use 13th assignment | list | No |
| Use 14th assignment | list | No |
| Use 15th assignment | list | No |
| Use 16th assignment | list | No |
| Use 17th assignment | list | No |
| Use 18th assignment | list | No |
| Enable communication object
"Status Height/Slat 0...255" 1 byte | list | No |
| Enable communication object
"Status Height 0...255" 1 byte | list | No |
| Enable communication object
"Status Upper/Lower end pos." 1 bit | list | No |
| Enable communication object
"Status Automatic" 1 bit | list | No |
| B: Scene | list | Deactivated |