SJR/S4.24.2.1 Blind/RollerShutterAct,4f,SMI LoVo 2CDG 110 143 R0011
ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 143 R0011 · Shading Control › Blind Actuators SMI
Blind/Roller Shutter 4f SMI LoVo M/1.5
Download .knxprod Blind/Roller Shutter 4f SMI LoVo M/1.5 1.5 · 229 KB
Product
| Manufacturer | ABB AG - STOTZ-KONTAKT |
|---|---|
| Product name | SJR/S4.24.2.1 Blind/RollerShutterAct,4f,SMI LoVo |
| Order number | 2CDG 110 143 R0011 |
| Hardware | SJR/S4.24.2.1 Jal./Rol.Akt. 4f, SMI LoVo, REG |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Registered · 2023-03-23 |
| Languages | en-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU |
| Catalog entry | M-0002_H-2CDG.20110.20143.20R0011-2_HP-A07F-15-86CA_CI-2CDG.20110.20143.20R0011-1 |
| Fingerprint | 86CA |
| SHA-256 | c85abb1852b72a88ff82a153180f5acf3f34c5c95d030034d6cdc67da94e5f77 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Blind/Roller Shutter 4f SMI LoVo M/1.5 1.5
| Application number | $A07F |
|---|---|
| Version | 1.5 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 568 |
| Group objects | 147 |
Group objects (147)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Object 1 | Inisible | 1 Bit | 1.1 switch | CW |
| 1 | Output A | Move blinds Up-Down | 1 Bit | 1.8 up/down | CW |
| 1 | Output A | Move shutter Up-Down | 1 Bit | 1.8 up/down | CW |
| 2 | Output A | Louvre adj./ Stop Up-Down | 1 Bit | 1.7 step | CW |
| 2 | Output A | STOP | 1 Bit | 1.7 step | CW |
| 3 | Output A | Blinds Up-Down limited | 1 Bit | 1.8 up/down | CW |
| 3 | Output A | Shutter Up-Down limited | 1 Bit | 1.8 up/down | CW |
| 4 | Output A | Move to position 0..255 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 5 | Output A | Move louvre 0..255 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 6 | Output A | Move to position 1/2 | 1 Bit | 1.22 scene | CW |
| 7 | Output A | Move to position 3/4 | 1 Bit | 1.22 scene | CW |
| 8 | Output A | Set position 1/2 | 1 Bit | 1.22 scene | CW |
| 9 | Output A | Set position 3/4 | 1 Bit | 1.22 scene | CW |
| 10 | Output A | Activation of aut. Control | 1 Bit | 1.3 enable | CWTU |
| 11 | Output A | Sun | 1 Bit | 1.2 boolean | CWTU |
| 12 | Output A | Move to pos. for sun 0..255 | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 13 | Output A | Adjust louvres for sun 0..255 | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 14 | Output A | Presence | 1 Bit | 1.18 occupancy | CWTU |
| 15 | Output A | Heating | 1 Bit | 1.2 boolean | CWTU |
| 16 | Output A | Cooling | 1 Bit | 1.2 boolean | CWTU |
| 17 | Output A | Enable/disable automatic | 1 Bit | 1.2 boolean | CWTU |
| 18 | Output A | Enable/ block direct control | 1 Bit | 1.2 boolean | CWTU |
| 19 | Output A | Block | 1 Bit | 1.5 alarm | CW |
| 20 | Output A | Forced operation | 2 Bit | 2.5 alarm control | CW |
| 21 | Output A | Status of position 0..255 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 22 | Output A | Status louvre 0..255 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 23 | Output A | Status of upper pos. | 1 Bit | 1.11 state | CRT |
| 24 | Output A | Status of lower pos. | 1 Bit | 1.11 state | CRT |
| 25 | Output A | Status of operation | 1 Bit | 1.11 state | CRT |
| 26 | Output A | Status of aut. control | 1 Bit | 1.11 state | CRT |
| 27 | Output A | Status byte | 1 Byte | CRT | |
| 28 | Output A | Status SMI failure | 1 Bit | 1.11 state | CRT |
| 29 | Output A | Status number of drives | 1 Bit | 1.11 state | CRT |
| 30 | Output A | Diagnostic byte | 1 Byte | CRT | |
| 31 | Output B | Move blinds Up-Down | 1 Bit | 1.8 up/down | CW |
| 31 | Output B | Move shutter Up-Down | 1 Bit | 1.8 up/down | CW |
| 32 | Output B | Louvre adj./ Stop Up-Down | 1 Bit | 1.7 step | CW |
| 32 | Output B | STOP | 1 Bit | 1.7 step | CW |
| 33 | Output B | Blinds Up-Down limited | 1 Bit | 1.8 up/down | CW |
| 33 | Output B | Shutter Up-Down limited | 1 Bit | 1.8 up/down | CW |
| 34 | Output B | Move to position 0..255 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 35 | Output B | Move louvre 0..255 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 36 | Output B | Move to position 1/2 | 1 Bit | 1.22 scene | CW |
| 37 | Output B | Move to position 3/4 | 1 Bit | 1.22 scene | CW |
| 38 | Output B | Set position 1/2 | 1 Bit | 1.22 scene | CW |
| 39 | Output B | Set position 3/4 | 1 Bit | 1.22 scene | CW |
| 40 | Output B | Activation of aut. Control | 1 Bit | 1.3 enable | CWTU |
| 41 | Output B | Sun | 1 Bit | 1.2 boolean | CWTU |
| 42 | Output B | Move to pos. for sun 0..255 | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 43 | Output B | Adjust louvres for sun 0..255 | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 44 | Output B | Presence | 1 Bit | 1.18 occupancy | CWTU |
| 45 | Output B | Heating | 1 Bit | 1.2 boolean | CWTU |
| 46 | Output B | Cooling | 1 Bit | 1.2 boolean | CWTU |
| 47 | Output B | Enable/disable automatic | 1 Bit | 1.2 boolean | CWTU |
| 48 | Output B | Enable/ block direct control | 1 Bit | 1.2 boolean | CWTU |
| 49 | Output B | Block | 1 Bit | 1.5 alarm | CW |
| 50 | Output B | Forced operation | 2 Bit | 2.5 alarm control | CW |
| 51 | Output B | Status of position 0..255 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 52 | Output B | Status louvre 0..255 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 53 | Output B | Status of upper pos. | 1 Bit | 1.11 state | CRT |
| 54 | Output B | Status of lower pos. | 1 Bit | 1.11 state | CRT |
| 55 | Output B | Status of operation | 1 Bit | 1.11 state | CRT |
| 56 | Output B | Status of aut. control | 1 Bit | 1.11 state | CRT |
| 57 | Output B | Status byte | 1 Byte | CRT | |
| 58 | Output B | Status SMI failure | 1 Bit | 1.11 state | CRT |
| 59 | Output B | Status number of drives | 1 Bit | 1.11 state | CRT |
| 60 | Output B | Diagnostic byte | 1 Byte | CRT | |
| 61 | Output C | Move blinds Up-Down | 1 Bit | 1.8 up/down | CW |
| 61 | Output C | Move shutter Up-Down | 1 Bit | 1.8 up/down | CW |
| 62 | Output C | Louvre adj./ Stop Up-Down | 1 Bit | 1.7 step | CW |
| 62 | Output C | STOP | 1 Bit | 1.7 step | CW |
| 63 | Output C | Blinds Up-Down limited | 1 Bit | 1.8 up/down | CW |
| 63 | Output C | Shutter Up-Down limited | 1 Bit | 1.8 up/down | CW |
| 64 | Output C | Move to position 0..255 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 65 | Output C | Move louvre 0..255 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 66 | Output C | Move to position 1/2 | 1 Bit | 1.22 scene | CW |
| 67 | Output C | Move to position 3/4 | 1 Bit | 1.22 scene | CW |
| 68 | Output C | Set position 1/2 | 1 Bit | 1.22 scene | CW |
| 69 | Output C | Set position 3/4 | 1 Bit | 1.22 scene | CW |
| 70 | Output C | Activation of aut. Control | 1 Bit | 1.3 enable | CWTU |
| 71 | Output C | Sun | 1 Bit | 1.2 boolean | CWTU |
| 72 | Output C | Move to pos. for sun 0..255 | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 73 | Output C | Adjust louvres for sun 0..255 | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 74 | Output C | Presence | 1 Bit | 1.18 occupancy | CWTU |
| 75 | Output C | Heating | 1 Bit | 1.2 boolean | CWTU |
| 76 | Output C | Cooling | 1 Bit | 1.2 boolean | CWTU |
| 77 | Output C | Enable/disable automatic | 1 Bit | 1.2 boolean | CWTU |
| 78 | Output C | Enable/ block direct control | 1 Bit | 1.2 boolean | CWTU |
| 79 | Output C | Block | 1 Bit | 1.5 alarm | CW |
| 80 | Output C | Forced operation | 2 Bit | 2.5 alarm control | CW |
| 81 | Output C | Status of position 0..255 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 82 | Output C | Status louvre 0..255 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 83 | Output C | Status of upper pos. | 1 Bit | 1.11 state | CRT |
| 84 | Output C | Status of lower pos. | 1 Bit | 1.11 state | CRT |
| 85 | Output C | Status of operation | 1 Bit | 1.11 state | CRT |
| 86 | Output C | Status of aut. control | 1 Bit | 1.11 state | CRT |
| 87 | Output C | Status byte | 1 Byte | CRT | |
| 88 | Output C | Status SMI failure | 1 Bit | 1.11 state | CRT |
| 89 | Output C | Status number of drives | 1 Bit | 1.11 state | CRT |
| 90 | Output C | Diagnostic byte | 1 Byte | CRT | |
| 91 | Output D | Move blinds Up-Down | 1 Bit | 1.8 up/down | CW |
| 91 | Output D | Move shutter Up-Down | 1 Bit | 1.8 up/down | CW |
| 92 | Output D | Louvre adj./ Stop Up-Down | 1 Bit | 1.7 step | CW |
| 92 | Output D | STOP | 1 Bit | 1.7 step | CW |
| 93 | Output D | Blinds Up-Down limited | 1 Bit | 1.8 up/down | CW |
| 93 | Output D | Shutter Up-Down limited | 1 Bit | 1.8 up/down | CW |
| 94 | Output D | Move to position 0..255 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 95 | Output D | Move louvre 0..255 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 96 | Output D | Move to position 1/2 | 1 Bit | 1.22 scene | CW |
| 97 | Output D | Move to position 3/4 | 1 Bit | 1.22 scene | CW |
| 98 | Output D | Set position 1/2 | 1 Bit | 1.22 scene | CW |
| 99 | Output D | Set position 3/4 | 1 Bit | 1.22 scene | CW |
| 100 | Output D | Activation of aut. Control | 1 Bit | 1.3 enable | CWTU |
| 101 | Output D | Sun | 1 Bit | 1.2 boolean | CWTU |
| 102 | Output D | Move to pos. for sun 0..255 | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 103 | Output D | Adjust louvres for sun 0..255 | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 104 | Output D | Presence | 1 Bit | 1.18 occupancy | CWTU |
| 105 | Output D | Heating | 1 Bit | 1.2 boolean | CWTU |
| 106 | Output D | Cooling | 1 Bit | 1.2 boolean | CWTU |
| 107 | Output D | Enable/disable automatic | 1 Bit | 1.2 boolean | CWTU |
| 108 | Output D | Enable/ block direct control | 1 Bit | 1.2 boolean | CWTU |
| 109 | Output D | Block | 1 Bit | 1.5 alarm | CW |
| 110 | Output D | Forced operation | 2 Bit | 2.5 alarm control | CW |
| 111 | Output D | Status of position 0..255 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 112 | Output D | Status louvre 0..255 | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 113 | Output D | Status of upper pos. | 1 Bit | 1.11 state | CRT |
| 114 | Output D | Status of lower pos. | 1 Bit | 1.11 state | CRT |
| 115 | Output D | Status of operation | 1 Bit | 1.11 state | CRT |
| 116 | Output D | Status of aut. control | 1 Bit | 1.11 state | CRT |
| 117 | Output D | Status byte | 1 Byte | CRT | |
| 118 | Output D | Status SMI failure | 1 Bit | 1.11 state | CRT |
| 119 | Output D | Status number of drives | 1 Bit | 1.11 state | CRT |
| 120 | Output D | Diagnostic byte | 1 Byte | CRT | |
| 121 | Output A-D | Status of auxiliary voltage | 1 Bit | 1.11 state | CRT |
| 122 | Output A-D | Enable/ block manual operation | 1 Bit | 1.2 boolean | CW |
| 123 | Output A-D | Status of man. operation | 1 Bit | 1.11 state | CRT |
| 124 | Output A-D | Wind alarm no. 1 | 1 Bit | 1.5 alarm | CWTU |
| 125 | Output A-D | Wind alarm no. 2 | 1 Bit | 1.5 alarm | CWTU |
| 126 | Output A-D | Wind alarm no. 3 | 1 Bit | 1.5 alarm | CWTU |
| 127 | Output A-D | Rain alarm | 1 Bit | 1.5 alarm | CWTU |
| 128 | Output A-D | Frost alarm | 1 Bit | 1.5 alarm | CWTU |
| 129 | Output A-D | Scene | 1 Byte | 18.1 scene control | CW |
| 130 | Output A-D | Time for autom. reactivation | 2 Bytes | 7.6 time (min) | CW |
| 131 | Output A-D | Delay for sun = 1 | 2 Bytes | 7.5 time (s) | CW |
| 132 | Output A-D | Delay for sun = 0 | 2 Bytes | 7.5 time (s) | CW |
| 133 | Output A-D | Delay for presence=1 | 2 Bytes | 7.5 time (s) | CW |
| 134 | Output A-D | Delay for presence=0 | 2 Bytes | 7.5 time (s) | CW |
Parameters (102)
| Parameter | Type | Default |
|---|---|---|
| Konvertierbar ab Version 1.0 | unsignedInt 0…255 | 16 |
| Parameter settings | list | similar for all outputs |
| Time-delayed switching of drives | list | deactivated |
| Time delay [s] 1...15 | unsignedInt 1…15 | 1 |
| Maximum telegram rate | list | 1 telegram per second |
| Allow parameter changes via EIB/KNX | list | no |
| Overwrite parameter changing on download | list | no |
| Allow SMI service access | list | no |
| Manual operation | list | enabled |
| Reset manual operation to EIB/KNX operation | list | automatically and via push button |
| Time for automatic reset [s] 10..6,000 | unsignedInt 10…6000 | 300 |
| Send status of manual operation | list | no |
| Send status auxiliary voltage/ SMI supply voltage | list | no |
| Position after programming/ reset | list | STOP |
| Read automatic objects | list | no |
| Position on bus voltage failure | list | no reaction |
| Position after bus voltage recovery | list | STOP |
| Read automatic- and safety objects | list | no |
| Position after aux. voltage recovery | list | STOP |
| Order of priority for weather alarm functions | list | 1.Wind alarm - 2.Rain alarm - 3.Frost alarm |
| Communication object no. 1 for wind alarm | list | deactivated |
| Communication object no. 2 for wind alarm | list | deactivated |
| Communication object no. 3 for wind alarm | list | deactivated |
| Monitoring period for wind alarm [s] 0..1,000 (0 = monitoring deact.) | unsignedInt 0…1000 | 0 |
| Communication object for rain alarm | list | deactivated |
| Monitoring period for rain alarm [s] 0..1,000 (0 = monitoring deact.) | unsignedInt 0…1000 | 0 |
| Communication object for frost alarm | list | deactivated |
| Monitoring period for frost alarm [s] 0..1,000 (0 = monitoring deact.) | unsignedInt 0…1000 | 0 |
| Number of SMI drives Output A | unsignedInt 0…4 | 1 |
| Number of SMI drives Output B | unsignedInt 0…4 | 1 |
| Number of SMI drives Output C | unsignedInt 0…4 | 1 |
| Number of SMI drives Output D | unsignedInt 0…4 | 1 |
| Operating mode | list | Blinds |
| Rotation angle of motor shaft for a complete louvre adjustment 10..500 | unsignedInt 10…500 | 300 |
| Number of louvre adjustments 1..250 | unsignedInt 1…250 | 7 |
| Position of louvre after move-down [%] 0..100 | unsignedInt 0…100 | 100 |
| Limit travelling range | list | no |
| Upper limit [%] 0..100 | unsignedInt 0…100 | 0 |
| Lower limit [%] 0..100 | unsignedInt 0…100 | 100 |
| Output reacts on communication object for wind alarm no. | list | Output does not react to wind alarm |
| Position on wind alarm | list | deactivated |
| Position on rain alarm | list | deactivated |
| Position on frost alarm | list | deactivated |
| Position onfrost alarm | list | deactivated |
| Disable via communication object | list | deactivated |
| Position during blocking | list | no reaction |
| Forced operation | list | deactivated |
| Position on reset of weather alarm, blocking and forced operation | list | no reaction |
| Order of priority for safety alarm functions | list | 1.Weather alarm - 2.Block - 3.Forced Operation |
| Send position: 0..255 | list | no |
| Send position: limit position reached | list | no |
| Send status of operation | list | no |
| Send status of automatic control | list | no |
| Send status byte | list | no |
| Send status SMI failure | list | no |
| Send status number of SMI drives | list | no |
| Send SMI diagnostic byte | list | no |
| Move to position 0..255 | list | deactivated |
| Move to position: 1 bit preset | list | deactivated |
| Overwrite preset values during download | list | yes |
| Position 1 [%] 0..100 (0% = top; 100% = bottom) | unsignedInt 0…100 | 20 |
| Louvre 1 [%] 0..100 (0% = opened; 100% = closed) | unsignedInt 0…100 | 20 |
| Position 2 [%] 0..100 (0% = top; 100% = bottom) | unsignedInt 0…100 | 40 |
| Louvre 2 [%] 0..100 (0% = opened; 100% = closed) | unsignedInt 0…100 | 40 |
| Position 3 [%] 0..100 (0% = top; 100% = bottom) | unsignedInt 0…100 | 60 |
| Louvre 3 [%] 0..100 (0% = opened; 100% = closed) | unsignedInt 0…100 | 60 |
| Position 4 [%] 0..100 (0% = top; 100% = bottom) | unsignedInt 0…100 | 80 |
| Louvre 4 [%] 0..100 (0% = opened; 100% = closed) | unsignedInt 0…100 | 80 |
| Use sun automatic control | list | no |
| Deactivation of automatic control | list | via object "activation" and move command |
| Automatic reactivation of automatic control | list | deactivated |
| Time to reactivate automatic control automatically [min.] 10..6.000 | unsignedInt 10…6000 | 300 |
| Toggling to automatic control | list | enabled |
| Toggling to direct control | list | enabled |
| Position for sun = "1" (sun) | list | DOWN |
| Position for sun = "1" (sun) | list | DOWN |
| Position for sun = "0" (no sun) | list | UP |
| Position for sun = "0" (no sun) | list | UP |
| Delay for presence = "1" [s] 0..6,000 | unsignedInt 0…6000 | 0 |
| Delay for sun = "1" [s] 0..6,000 | unsignedInt 0…6000 | 0 |
| Delay for presence = "0" [s] 0..6,000 | unsignedInt 0…6000 | 0 |
| Delay for sun = "0" [s] 0..6,000 | unsignedInt 0…6000 | 0 |
| Heating/Cooling automatic control | list | deactivated |
| Delay for presence = "0" [s] 0..6,000 | unsignedInt 0…6000 | 600 |
| Position for heating = "1" and sun = "1" | list | UP |
| Position for heating = "1" and sun = "0" | list | no reaction |
| Position for cooling= "1" and sun = "1" | list | DOWN |
| Position for cooling = "1" and sun = "1" | list | DOWN |
| Position for cooling= "1" and sun = "0" | list | no reaction |
| Position for cooling = "1" and sun = "0" | list | no reaction |
| 1 byte scene | list | deactivated |
| Scene assignment (1) | list | no assignment |
| Scene assignment (2) | list | no assignment |
| Scene assignment (3) | list | no assignment |
| Scene assignment (4) | list | no assignment |
| Scene assignment (5) | list | no assignment |
| Scene assignment (6 | list | no assignment |
| Scene assignment (7) | list | no assignment |
| Scene assignment (8) | list | no assignment |
| Scene assignment (9) | list | no assignment |
| Scene assignment (10) | list | no assignment |
| Scene assignment (6) | list | no assignment |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Blind/Roller Shutter 4f SMI LoVo M/1.5 1.5 latest | $A07F | 86CA | 2026-11-25 | 229 KB | Download |
About this file
This is the official ETS product database for the ABB AG - STOTZ-KONTAKT SJR/S4.24.2.1 Blind/RollerShutterAct,4f,SMI LoVo (2CDG 110 143 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - STOTZ-KONTAKT
- JA/S4.SMI.1M Shutter Actuator man.,4-fold,SMI,MDRC 2CDG 110 028 R0011
- JRA/S2.230.2.1 Blind/RollerShutterAct,M,2f,230V 2CDG 110 120 R0011
- JRA/S4.230.2.1 Blind/RollerShutterAct,M,4f,230V 2CDG 110 121 R0011
- JRA/S8.230.2.1 Blind/RollerShutterAct,M,8f,230V 2CDG 110 122 R0011
- JRA/S2.230.5.1 Blind/RollerShutterAct,TD,M,2f,230V 2CDG 110 124 R0011
- JRA/S4.230.5.1 Blind/RollerShutterAct,TD,M,4f,230V 2CDG 110 125 R0011
- JRA/S8.230.5.1 Blind/RollerShutterAct,TD,M,8f,230V 2CDG 110 126 R0011
- JRA/S4.24.5.1 Blind/RollerShutterAct,TD,M,4f,24V 2CDG 110 128 R0011
- JRA/S2.230.1.1 Blind/RollerShutterAct,2f,230V 2CDG 110 129 R0011
- JRA/S4.230.1.1 Blind/RollerShutterAct,4f,230V 2CDG 110 130 R0011
- JRA/S8.230.1.1 Blind/RollerShutterAct,8f,230V 2CDG 110 131 R0011
- JRA/S6.230.3.1 Shutter Actuator, binary input,MDRC 2CDG 110 208 R0011