KNX Database

SA/S4.6.2.1 Switchact, 4f, 6A, M, MDRC 6195/40

ABB AG - BUSCH-JAEGER · Order number 6195/40 · Output › Binary output, 4-fold

Switch 4f 6M/3.2

Download .knxprod Switch 4f 6M/3.2 3.2 · 465 KB

Product

ManufacturerABB AG - BUSCH-JAEGER
Product nameSA/S4.6.2.1 Switchact, 4f, 6A, M, MDRC
Order number6195/40
HardwareSA/S4.6.2.1
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
Width (mm)72
RegistrationRegistered
Languagesde-DE, en-US
Catalog entryM-0007_H-2CDG.20110.20181.20R0011-1-O0002_HP-A096-32-C6C1-O0002_CI-6195.2F40-1
FingerprintC6C1
SHA-256e297e6700f7e7254f8cd749c65d10cbfb5bea78c4db620326b946145e585bfc8
First seen2026-11-25
MarketsAustralia

Application program: Switch 4f 6M/3.2 3.2

Application number$A096
Version3.2
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters551
Group objects114
Group objects (114)
NoNameFunctionSizeDPTFlags
0GeneralIn Operation1 Bit1.2 booleanCRT
1GeneralSafety Priority 11 BitCWU
2GeneralSafety Priority 21 BitCWU
3GeneralSafety Priority 31 BitCWU
4xDummy1 Bit1.1 switch
5xx1 Bit1.1 switch
6xx1 Bit1.1 switch
7xx1 Bit1.1 switch
8xx1 Bit1.1 switch
9xx1 Bit1.1 switch
10Output AControl value (PWM)1 Byte5.1 percentage (0..100%)CW
10Output ASwitch1 Bit1.1 switchCW
11Output ATrigger valve purge1 Bit1.1 switchCW
11Output APermanent ON1 Bit1.1 switchCW
12Output AStatus valve purge1 Bit1.2 booleanCT
12Output ADisable time function1 Bit1.3 enableCW
13Output ARTR fault1 BitCT
13Output ADuration of staircase lighting2 BytesCRW
14Output AForced operation1 Bit1.3 enableCW
14Output Awarning stair lighting1 BitCT
15Output AStatus heating1 Byte5.1 percentage (0..100%)CT
15Output AStatus heating1 Bit1.1 switchCT
15Output ACall preset 1/21 BitCW
16Output ASet preset 1/21 BitCW
17Output A8 bitScene1 ByteCW
18Output ALogical connection 11 Bit1.2 booleanCW
19Output ALogical connection 21 Bit1.2 booleanCW
20Output AForced Positioning2 Bit2.1 switch controlCW
20Output AForced Positioning1 Bit1.3 enableCW
21Output AThreshold input2 Bytes7.1 pulsesCW
21Output AThreshold input1 Byte5.10 counter pulses (0..255)CW
22Output AChange Threshold value 11 Byte5.10 counter pulses (0..255)CW
22Output AChange Threshold value 12 Bytes7.1 pulsesCW
23xx1 Bit1.1 switch
24xx1 Bit1.1 switch
29Output AStatus Switch1 Bit1.1 switchCRT
30Output BControl value (PWM)1 Byte5.1 percentage (0..100%)CW
30Output BSwitch1 Bit1.1 switchCW
31Output BTrigger valve purge1 Bit1.1 switchCW
31Output BPermanent ON1 Bit1.1 switchCW
32Output BStatus valve purge1 Bit1.2 booleanCT
32Output BDisable time function1 Bit1.3 enableCW
33Output BRTR fault1 BitCT
33Output BDuration of staircase lighting2 BytesCRW
34Output BForced operation1 Bit1.3 enableCW
34Output Bwarning stair lighting1 BitCT
35Output BStatus heating1 Byte5.1 percentage (0..100%)CT
35Output BStatus heating1 Bit1.1 switchCT
35Output BCall preset 1/21 BitCW
36Output BSet preset 1/21 BitCW
37Output B8 bitScene1 ByteCW
38Output BLogical connection 11 Bit1.2 booleanCW
39Output BLogical connection 21 Bit1.2 booleanCW
40Output BForced Positioning2 Bit2.1 switch controlCW
40Output BForced Positioning1 Bit1.3 enableCW
41Output BThreshold input2 Bytes7.1 pulsesCW
41Output BThreshold input1 Byte5.10 counter pulses (0..255)CW
42Output BChange Threshold value 11 Byte5.10 counter pulses (0..255)CW
42Output BChange Threshold value 12 Bytes7.1 pulsesCW
43xx1 Bit1.1 switch
44xx1 Bit1.1 switch
49Output BStatus Switch1 Bit1.1 switchCRT
50Output CControl value (PWM)1 Byte5.1 percentage (0..100%)CW
50Output CSwitch1 Bit1.1 switchCW
51Output CTrigger valve purge1 Bit1.1 switchCW
51Output CPermanent ON1 Bit1.1 switchCW
52Output CStatus valve purge1 Bit1.2 booleanCT
52Output CDisable time function1 Bit1.3 enableCW
53Output CRTR fault1 BitCT
53Output CDuration of staircase lighting2 BytesCRW
54Output CForced operation1 Bit1.3 enableCW
54Output Cwarning stair lighting1 BitCT
55Output CStatus heating1 Byte5.1 percentage (0..100%)CT
55Output CStatus heating1 Bit1.1 switchCT
55Output CCall preset 1/21 BitCW
56Output CSet preset 1/21 BitCW
57Output C8 bitScene1 ByteCW
58Output CLogical connection 11 Bit1.2 booleanCW
59Output CLogical connection 21 Bit1.2 booleanCW
60Output CForced Positioning2 Bit2.1 switch controlCW
60Output CForced Positioning1 Bit1.3 enableCW
61Output CThreshold input2 Bytes7.1 pulsesCW
61Output CThreshold input1 Byte5.10 counter pulses (0..255)CW
62Output CChange Threshold value 11 Byte5.10 counter pulses (0..255)CW
62Output CChange Threshold value 12 Bytes7.1 pulsesCW
63xx1 Bit1.1 switch
64xx1 Bit1.1 switch
69Output CStatus Switch1 Bit1.1 switchCRT
70Output DSwitch1 Bit1.1 switchCW
70Output DControl value (PWM)1 Byte5.1 percentage (0..100%)CW
71Output DPermanent ON1 Bit1.1 switchCW
71Output DTrigger valve purge1 Bit1.1 switchCW
72Output DDisable time function1 Bit1.3 enableCW
72Output DStatus valve purge1 Bit1.2 booleanCT
73Output DDuration of staircase lighting2 BytesCRW
73Output DRTR fault1 BitCT
74Output Dwarning stair lighting1 BitCT
74Output DForced operation1 Bit1.3 enableCW
75Output DCall preset 1/21 BitCW
75Output DStatus heating1 Byte5.1 percentage (0..100%)CT
75Output DStatus heating1 Bit1.1 switchCT
76Output DSet preset 1/21 BitCW
77Output D8 bitScene1 ByteCW
78Output DLogical connection 11 Bit1.2 booleanCW
79Output DLogical connection 21 Bit1.2 booleanCW
80Output DForced Positioning2 Bit2.1 switch controlCW
80Output DForced Positioning1 Bit1.3 enableCW
81Output DThreshold input2 Bytes7.1 pulsesCW
81Output DThreshold input1 Byte5.10 counter pulses (0..255)CW
82Output DChange Threshold value 11 Byte5.10 counter pulses (0..255)CW
82Output DChange Threshold value 12 Bytes7.1 pulsesCW
83xx1 Bit1.1 switch
84xx1 Bit1.1 switch
89Output DStatus Switch1 Bit1.1 switchCRT
Parameters (103)
ParameterTypeDefault
Transmission and switching delay after recovery of bus voltage (2...255s)unsignedInt 2…2552
Telegrammrate_Zeittics 59 = 1secunsignedInt 0…25559
Send cyclical "In operation" telegram (0...65.535s, 0 = inactiv)unsignedInt 0…655350
Enable Safety object for operating mode "Switch Actuator"listno
Hinweis: Aktion des Ausgangs auf "Funktion Sicherheit Priorität x"listis set on parameter-window "X: Safety"
Function Safety Priority 1listinactive
Control period in seconds (0...65.535, 0 = inactive)unsignedInt 0…655350
Function Safety Priority 2listinactive
Function Safety Priority 3listinactive
Operating mode of output AlistSwitch Actuator
Status response of switching state object "Status Switch"listonly after changing
object value switching status (object "Status Switch")list1=closed, 0=open
Reaction on bus voltage failurelistContact unchanged
Connected valve typelistnormally closed
Control telegram is received aslist1 bit (PWM or on-off control)
Transmit status response object "Status heating"listno
Value object "Switch" on bus voltage recoverylistnot write
Overwrite scene, preset and threshold value 1 with downloadlistyes
PWM-cycle time for continuous control Minutes (3...65.535)unsignedInt 3…6553510
PWM-cycle time for continuous control Seconds (0...59)unsignedInt 0…590
Position of the valve drive on bus voltage recoverylist0% (closed)
Enable monitoring of the controllerlistno
Enable function "forced operation"listno
Reaction of output AlistNormally open contact
Enable function "valve purge"listno
Enable time functions "delay, staircase lighting, flashing"listno
Value object "Disable Time Function" after bus voltage recoverylist"0", enable time functions
Enable function "presets"listno
Enable function "scene (8 bit)"listno
Enable function "logic"listno
Enable functions "priorty and safety, operation"listno
Enable function "threshold"listno
State without functionlistnot write
Time functionlistStaircase lighting function
Flashing if object "Switching" islistalways flashing, ON (1) or OFF (0)
in seconds (0...59)unsignedInt 0…590
in minutes (0...65.535)unsignedInt 0…6553560
Duration of staircase lighting Minutes (0...1000)unsignedInt 0…10005
Delay for switching on: (Min.(0...65535)unsignedInt 0…655350
Time for ON: Min. (0...65.535)unsignedInt 0…655350
Time for ON: Sec. (1...59)unsignedInt 1…595
Seconds (0...59)unsignedInt 0…590
Delay for switching on: Sec. (0...59)unsignedInt 0…590
Time for OFF: Min. (0...65.535)unsignedInt 0…655350
Delay for switching OFF: Min. (0...65.53unsignedInt 0…655350
Position of the valve drive during fault of room thermostatlistunchanged
Time for OFF: Sec. (1...59)unsignedInt 1…595
Delay for switching OFF: Sec. (0...59)unsignedInt 0…590
Number of ON-impulses: (1...100)unsignedInt 1…1005
Extending staircase lighting by multiple operation ("pumping up")listyes (retriggerable)
Enable object "RTR fault"listno
Contact position after flashinglistcalculate present contact position
Staircase lighting can be switched offlistON with "1" and OFF with "0"
Warning before end of staircase lightinglistvia object
Warning time in sec. (0...65.535) add to duration of staircase lightingunsignedInt 0…6553545
Valve position during forced positioninglistunchanged
Duration of staircase lighting can be changed by objectlistno
Note: Observe contact life and switching frequency per minutelistsee technical data
Restart of staircase time after end of permanent ONlistno
Time of valve purge in minutes (0...255)unsignedInt 0…25510
Automatic valve purgelistdisable
Automatische SpülungunsignedInt 0…650000
Reaction on preset 1 (telegr. value 0)listno reaction
Reaction on preset 2 (telegr. value 1)listno reaction
Preset can be set via the buslistyes
Output is assigned to (Scene 1...64)listno allocation
Standard valuelistON
Logical Connection 1listdisable
Function of object "Logical connection2"listAND
Gate disabled, if Object value "Logical connection 1" islist"0"
Result is invertedlistno
Object value "Logical connection 1" after bus voltage recoverylist"0"
Logical Connection 2listdisable
Gate disabled, if Object value "Logical connection 2" islist"0"
Object value "Logical connection 2" after bus voltage recoverylist"0"
Enable "Safety Priority x"liston parameter-window "General"
Contact position if Safety Priority 1listinactive
Contact position if forced operationlistinactive
Object value "Forced positioning" on bus voltage recoverylistdisable
Object value "Forced positioning" on bus voltage recoverylist"0" inactive
Contact position if Safety Priority 2listinactive
Contact position if Safety Priority 3listinactive
Reaction when forced operation and all Safety Priority x endlistcalculate present contact position
Data type of object "Threshold input"list1 byte (0...255)
Change Threshold 1 over buslistno
Threshold value 1 (0...65.535))unsignedInt 0…6553520000
Threshold value 1 (0...255)unsignedInt 0…25580
Threshold value 2 (0...255)unsignedInt 0…255160
Threshold value 2 (0...65.535)unsignedInt 0…6553540000
Threshold values define hysteresislistyes
Falling below lower thresholdlistno reaction
Object value < lower thresholdlistno reaction
Lower thrsh. <= object <= upper thrsh.listno reaction
Object value > lower thresholdlistno reaction
Exceeding upper thresholdlistno reaction
Object "threshold input" value on bus voltage recovery (0...255)unsignedInt 0…2550
Object "threshold input" value on bus voltage recovery (0...65.535)unsignedInt 0…655350
Operating mode of output BlistSwitch Actuator
Reaction of output BlistNormally open contact
Operating mode of output ClistSwitch Actuator
Reaction of output ClistNormally open contact
Operating mode of output DlistSwitch Actuator
Reaction of output DlistNormally open contact

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch 4f 6M/3.2 3.2 latest$A096C6C12026-11-25465 KBDownload

About this file

This is the official ETS product database for the ABB AG - BUSCH-JAEGER SA/S4.6.2.1 Switchact, 4f, 6A, M, MDRC (6195/40), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from ABB AG - BUSCH-JAEGER

All ABB AG - BUSCH-JAEGER products