6138/11-xx RTR fan coil with display, SM 6138/11-xx
ABB AG - BUSCH-JAEGER · Order number 6138/11-xx · Heating, Ventilation and Air Conditioning › Thermostats
Download .knxprod Display operate control FanCoil /1.0 1.0 · 107 KB
Product
| Manufacturer | ABB AG - BUSCH-JAEGER |
|---|---|
| Product name | 6138/11-xx RTR fan coil with display, SM |
| Order number | 6138/11-xx |
| Product text | 6138/11-xx RTR FanCoil mit Display, AP |
| Hardware | 6138/11-xx RTR FanCoil mit Display, AP |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Registered |
| Languages | de-DE, en-US, fr-FR |
| Catalog entry | M-0007_H-07-6138_HP-6138-10-48DB_CI-6138.2F11.2Dxx-1 |
| Fingerprint | 48DB |
| SHA-256 | 867ac7ccba2985ac884b0bbdb35ae23bd770281dc6e24553f58d6d99df6d4194 |
| First seen | 2026-11-25 |
| Markets | Australia, Austria, Belgium, France, Germany, Netherlands |
Application program: Display operate control FanCoil /1.0 1.0
| Application number | $6138 |
|---|---|
| Version | 1.0 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 181 |
| Group objects | 70 |
Group objects (70)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | In Operation | General | 1 Bit | CT | |
| 0 | General | In Operation | 1 Bit | CT | |
| 1 | General | Unit On/Off | 1 Bit | CRWT | |
| 2 | General | Switch °C/°F display unit | 1 Bit | CRW | |
| 3 | General | Illumination On/Off | 1 Bit | CW | |
| 4 | Control | Frost/heat protection | 1 Bit | CRW | |
| 5 | Control | Activate night mode | 1 Bit | CRW | |
| 6 | Control | User absent | 1 Bit | CRWT | |
| 7 | Control | Operating mode switchover | 1 Byte | CRWT | |
| 8 | Control | Operating mode switchover OMO | 1 Byte | CRW | |
| 9 | Temperature sensor | Send setpoint | 2 Bytes | CRT | |
| 10 | Temperature recording | Input current exterior temperature | 2 Bytes | CW | |
| 11 | Temperature recording | Input exterior temperature | 2 Bytes | CW | |
| 12 | Control | Current setpoint cooling | 2 Bytes | CRWT | |
| 13 | Control | Current setpoint heating | 2 Bytes | CRWT | |
| 14 | Control | Base setpoint | 2 Bytes | CRW | |
| 15 | Control | Heating setpoint comfort | 2 Bytes | CRW | |
| 16 | Control | Heating setpoint standby | 2 Bytes | CRW | |
| 17 | Control | Heating setpoint night mode | 2 Bytes | CRW | |
| 18 | Control | Setpoint frost protection | 2 Bytes | CRW | |
| 19 | Control | Cooling setpoint comfort | 2 Bytes | CRW | |
| 20 | Control | Cooling setpoint standby | 2 Bytes | CRW | |
| 21 | Control | Cooling setpoint night mode | 2 Bytes | CRW | |
| 22 | Control | Setpoint heat protection | 2 Bytes | CRW | |
| 23 | Control | Reset of local operation | 1 Bit | CW | |
| 24 | Control value | Control value heating | 1 Byte | CRT | |
| 24 | Control value | Control value heating | 1 Bit | CRT | |
| 24 | Control value | Control value heat/cool | 1 Bit | CRT | |
| 24 | Control value | Control value heat/cool | 1 Byte | CRT | |
| 24 | Control value | Control value heating | 1 Byte | CW | |
| 24 | Control value | Control value heating | 1 Bit | CW | |
| 24 | Control value | Control value heat/cool | 1 Bit | CW | |
| 24 | Control value | Control value heat/cool | 1 Byte | CW | |
| 25 | Control value | Control value cooling | 1 Byte | CRT | |
| 25 | Control value | Control value cooling | 1 Bit | CRT | |
| 25 | Control value | Control value cooling 4-pipe | 1 Bit | CRT | |
| 25 | Control value | Control value cooling 4-pipe | 1 Byte | CRT | |
| 25 | Control value | Control value cooling | 1 Byte | CW | |
| 25 | Control value | Control value cooling | 1 Bit | CW | |
| 25 | Control value | Control value cooling 4-pipe | 1 Bit | CW | |
| 25 | Control value | Control value cooling 4-pipe | 1 Byte | CW | |
| 26 | Control value | Contr. value add. heat. stage | 1 Bit | CRT | |
| 26 | Control value | Contr. value add. heat. stage | 1 Byte | CRT | |
| 27 | Control value | Contr. value add. cool. stage | 1 Bit | CRT | |
| 27 | Control value | Contr. value add. cool. stage | 1 Byte | CRT | |
| 28 | Control value | Status heat requirement | 1 Bit | CRT | |
| 28 | Control value | Status heat requirement | 1 Bit | CW | |
| 29 | Control value | Status cooling requirement | 1 Bit | CRT | |
| 29 | Control value | Status cooling requirement | 1 Bit | CW | |
| 30 | Heat/Cool | Heat/cool switchover | 1 Bit | CRWT | |
| 30 | Heat/Cool | Heat/cool switchover | 1 Bit | CW | |
| 31 | Fan automatic / manual | Manual On/Off | 1 Bit | CRWT | |
| 31 | Fan automatic / manual | Automatic On/Off | 1 Bit | CRWT | |
| 32 | Fan manual | Fan stage manual 1 byte | 1 Byte | CRWT | |
| 33 | Status FanCoil operation | Status operating state of FanCoil | 1 Byte | CW | |
| 34 | Fan manual | Switch FanCoil level 1 | 1 Bit | CRWT | |
| 35 | Fan manual | Switch FanCoil level 2 | 1 Bit | CRWT | |
| 36 | Fan manual | Switch FanCoil level 3 | 1 Bit | CRWT | |
| 37 | Actuator monitoring | Receive in operation | 1 Bit | CW | |
| 39 | Dew-point monitoring | Signal dew point | 1 Bit | CW | |
| 40 | Monitoring of condensate tank | Signal condensate tank | 1 Bit | CW | |
| 41 | Alarm temperature | Report failure of current temp. | 1 Bit | CRT | |
| 42 | Alarm temperature | Report failure of ext. temp. | 1 Bit | CRT | |
| 43 | Status byte | Status byte RHCC status | 2 Bytes | CRT | |
| 44 | Status byte | Status byte HVAC status | 2 Bytes | CRT | |
| 45 | Control | Summer compensation active | 1 Bit | CRT | |
| 46 | Control | Winter compensation active | 1 Bit | CRT | |
| 47 | Status FanCoil operation | Status stage 1 | 1 Bit | CW | |
| 48 | Status FanCoil operation | Status stage 2 | 1 Bit | CW | |
| 49 | Status FanCoil operation | Status stage 3 | 1 Bit | CW |
Parameters (100)
| Parameter | Type | Default |
|---|---|---|
| Send "In operation" object | list | No |
| Send cycle time in s [1...65.535] | unsignedInt 1…65535 | 60 |
| Enable switchover of temperature display via button °C/°F | list | Yes, standard °C |
| Display during normal operation | list | Absolute setpoint temperature |
| Display in adjusting mode | list | Absolute setpoint temperature |
| Display heat/cool is active | list | When requesting heating or cooling |
| Display illumination | list | 5 seconds recovery time |
| Operating mode switchover | list | 1 Byte (2 x DPT_HVAC mode) |
| Enable switchover of comfort/standby via button On/Off | list | No |
| Operation mode after reset and after Off | list | Comfort operation |
| Offset for room temp. meas. (measured value change by (-128..127)x0.1 K | signedInt -128…127 | 0 |
| Setpoint larger when sending change | list | Inactive |
| Send setpoint cyclic (0 - inactive, min) | unsignedInt 0…60 | 0 |
| Measurement of room temperature | list | Interior |
| Weighting interior / exterior | list | 50 % / 50 % |
| Monitoring temperature measurement | list | No |
| Control value at temp. measuring error | list | Final value |
| Monitoring time exterior temperature (0 - inactive, min) | unsignedInt 0…60 | 10 |
| Offset for ext. temp. meas. (measured value change by (-128..127)x0.1 K | signedInt -128…127 | 0 |
| Operating mode of unit | list | Normal operation with control function |
| Used control functions | list | Heat and cool |
| Switchover between heating and cooling | list | Automatic |
| Additional heating stage active | list | No |
| Additional cooling stage active | list | No |
| Condensate alarm active | list | No |
| Dew-point alarm active | list | No |
| Operation mode after reset and after Off | list | Heating |
| Number of output channels | list | 2 channels (four-pipe system) for heat / cool |
| Status send heat requirement | list | No |
| Cycle time heating control value sending (0 - inactive, min) | unsignedInt 0…60 | 0 |
| Control mode | list | FanCoil |
| Hysteresis | list | 1,0 K |
| Invert heating | list | No |
| Control parameter | list | Acc. to installation type |
| Type of heating system | list | Split unit (4 K / 90 min) |
| Proportional range (Xp) | list | 4,0 K |
| Readjust time (Tn) | list | 90 min |
| Minimum control value | list | 0 % |
| Maximum control value | list | 100 % |
| Control value larger when sending change | list | 0 % |
| Readjust time | list | 90 min |
| Cycle time PWM control value (min) | unsignedInt 1…60 | 15 |
| PWM cycle is 0% up to control value | list | 10 % |
| PWM cycle is 100 % up to control value | list | 90 % |
| Status send cooling requirement | list | No |
| Cycle time cooling control value sending (0 - inactive, min) | unsignedInt 0…60 | 0 |
| Invert cooling | list | No |
| Type of cooling system | list | Split unit (blower convector 4 K / 90 min) |
| Type of control value | list | Switching (1 Bit) |
| Invert control value | list | No |
| Hysteresis (one-sided) | list | 1,0 K |
| Cycle time for sending of control value (0 - inactive, min) | unsignedInt 0…60 | 0 |
| Interval of additional level (value change by (0..127)x0.1 K | unsignedInt 0…127 | 30 |
| Cyclic sending of setpoint (0 - inactive, min) | unsignedInt 0…60 | 0 |
| Cycle time sending of setpoint (0 - inactive, min) | unsignedInt 0…60 | 0 |
| Select base setpoint | list | Dependent setpoints |
| Reference base setpoint | list | Setpoint heating |
| Manual setpoint adjustment at reset of change from night / to night | list | Yes |
| Manual setpoint adjustment | list | Active |
| Maximum manual setpoint increase | unsignedInt 0…10 | 3 |
| Maximum manual setpoint reduction | unsignedInt 0…10 | 3 |
| Object reset manual setpoint adjustment active | list | No |
| When receiving base setpoint | list | Retain manual setpoint adjustment |
| Range manual setpoint adjustment | list | 0,1 K |
| Long press of button to enable change of setpoint heating / cooling | list | Yes |
| Heating setpoint comfort mode | list | 21,0 °C |
| Heating setpoint standby mode | list | 19,0 °C |
| Heating setpoint night mode | list | 15,0 °C |
| Cooling setpoint comfort mode | list | 23,0 °C |
| Cooling setpoint standby mode | list | 25,0 °C |
| Cooling setpoint night mode | list | 27,0 °C |
| Setpoint frost protection | list | 7 °C |
| Setpoint heat protection | list | Cooling disabled |
| Skip zone between heating/cooling | list | 2,0 K |
| Heating setpoint reduction standby | list | 2,0 K |
| Heating setpoint reduction night operation | list | 4,0 K |
| Cooling setpoint reduction standby | list | 2,0 K |
| Cooling setpoint reduction night operation | list | 4,0 K |
| Number of fan levels | list | 3 levels |
| Manual operation of fan stage is signaled to the actuator via | list | Object "Automatic ON/OFF" |
| Object manual fan stage send hat has the following code | list | 1-Byte object as counting value 0-3 |
| Evaluate status byte operation | list | No |
| Send cycle time of actuator in s [1...65.535] | unsignedInt 1…65535 | 120 |
| Stage of fan after reset and after Off | list | Automatic |
| Stage limit in night mode | list | No limit |
| Automatic return from manual adjustment (0 - inactive, min) | unsignedInt 0…60 | 0 |
| Return inactive a fan stage off and automatic return not 0 | list | Yes |
| Threshold value stage 1 | unsignedInt 1…100 | 10 |
| Threshold value stage 2 | unsignedInt 1…100 | 40 |
| Threshold value stage 3 | unsignedInt 1…100 | 70 |
| Summer compensation active | list | No |
| Summer compensation lower exterior temp. value | list | 20 °C |
| Summer compensation upper exterior temp. value | list | 32 °C |
| Summer compensation lower setpoint offset | list | 0 K |
| Summer compensation upper setpoint offset | list | 4 K |
| Winter compensation active | list | No |
| Winter compensation lower exterior temp. value | list | 0 °C |
| Winter compensation upper exterior temp. value | list | 10 °C |
| Winter compensation lower setpoint offset | list | 4 K |
| Winter compensation upper setpoint offset | list | 0 K |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| FanCoil Display Operate Control/1.0 1.2 latest | $6138 | 9EAF | 2026-11-25 | 112 KB | Download |
| Display operate control FanCoil /1.0 1.0 | $6138 | 48DB | 2026-11-25 | 107 KB | Download |
About this file
This is the official ETS product database for the ABB AG - BUSCH-JAEGER 6138/11-xx RTR fan coil with display, SM (6138/11-xx), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - BUSCH-JAEGER
- FCC/S1.1.2.11 Fan Coil Controller,PWM,3-speed,manual operation,MDRC 2CDG 110 211 R0021
- FCC/S1.2.2.11 Fan Coil Controller,0-10V,3-speed,manual operation,MDRC 2CDG 110 213 R0021
- FCC/S1.3.2.11 Fan Coil Controller,0-10V,0-10V,manual operation,MDRC 2CDG 110 215 R0021
- VC/S4.1.11 Valve Drive Controller,4-fold,MDRC 2CDG 110 216 R0021
- VC/S4.2.11 Valve Drive Controller,manual operation,4-fold,MDRC 2CDG 110 217 R0021
- FCC/S1.5.2.11 Fan Coil Controller,PWM,0-10V,manual operation,MDRC 2CDG 110 235 R0021
- 6164/40-101 Elektronischer Schaltaktor 4f,1A,REG 6164/40-101
- 6164/44 Electronic Switch Actuator,8f,1A,MDRC 6164/44
- VAA/S6.230.2.1 Valve Drive Actuator, 6f, 230V,MDRC 6164/45
- VAA/S12.230.2.1 Valve Drive Actuator, 12f, 230V 6164/46
- SUG/U 1.1 Split Unit Gateway 6186/40
- IPS/S3.5.11 IP Interface Secure,MDRC 2CDG 110 204 R0021