Zennio ZVIFDV2 Flat Display v2

Flat Display v2 ZVIFDV2

Zennio · Order number ZVIFDV2 · Display › LCD Display

Capacitive switch with display and humidity sensor

Download .knxprod Flat Display v2 2.6 2.6 · 843 KB

Product

ManufacturerZennio
Product nameFlat Display v2
Order numberZVIFDV2
HardwareFlat Display v2
MediumTwisted Pair
Bus current (mA)22.5
Rail mountedNo
RegistrationCertified · 2022-02-17
Languagesen-US, es-ES, de-DE, fr-FR, it-IT, ru-RU, uk-UA
Catalog entryM-0071_H-ZVIFDV2-1_HP-52A1-26-B4E5_CI-ZVIFDV2-1
FingerprintB4E5
SHA-25649446b5a675b5b87352a20613ee50cb02e5bc379e1ef877b8d1a887dd56af12e
First seen2026-11-25
Markets59 markets

Application program: Flat Display v2 2.6 2.6

Application number$52A1
Version2.6
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters2454
Group objects1137
Group objects (1137)
NoNameFunctionSizeDPTFlags
1[Heartbeat] Object to Send '1'Sending of '1' Periodically1 Bit1.17 triggerCRT
2[Heartbeat] Device RecoverySend 01 Bit1.17 triggerCRT
3[Heartbeat] Device RecoverySend 11 Bit1.17 triggerCRT
4[General] Time of DayTime of Day External Reference3 Bytes10.1 time of dayCWTU
5[General] DateDate External Reference3 Bytes11.1 dateCWTU
6[General] Scene: Receive0-63 (Run Scene 1-64)1 Byte17.1 scene numberCW
7[General] Scene: Send0-63/128-191 (Run/Save Scene 1-64)1 Byte18.1 scene controlCT
8[General] Activity0 = Inactivity; 1 = Activity1 Bit1.11 stateCW
9[General] Touch Locking0 = Unlock; 1 = Lock1 Bit1.3 enableCWTU
9[General] Touch Locking0 = Lock; 1 = Unlock1 Bit1.3 enableCWTU
10[General] Cleaning Function0 = Nothing; 1 = Clean Now1 Bit1.16 acknowledgeCW
11[General] External TemperatureTemperature to Be Shown2 Bytes9.1 temperature (°C)CWTU
12[General] Backlight Mode0 = Night Mode; 1 = Normal Mode1 Bit1.24 day/nightCW
12[General] Backlight Mode0 = Normal Mode; 1 = Night Mode1 Bit1.24 day/nightCW
13[General] Display - Brightness0% ... 100%1 Byte5.1 percentage (0..100%)CW
14[General] Display - Contrast0% ... 100%1 Byte5.1 percentage (0..100%)CW
15[General] Proximity Sensor0 = Disable; 1 = Enable1 Bit1.3 enableCW
16[General] External Proximity Detection1 = Detection1 Bit1.10 start/stopCW
17[General] Proximity DetectionSend 1 when Proximity is Detected1 Bit1.10 start/stopCT
18[General] Luminosity (1-Bit)0 = Over Threshold; 1 = Under Threshold1 Bit1.2 booleanCT
18[General] Luminosity (1-Bit)0 = Under Threshold; 1 = Over Threshold1 Bit1.2 booleanCT
19[General] Luminosity (Percentage)0% ... 100%1 Byte5.1 percentage (0..100%)CR
20[General] Luminosity (Lux)0 Lux ... 670760 Lux2 Bytes9.4 lux (Lux)CR
21[General] Welcome Greeting0 = Finish Welcome; 1 = Run Welcome1 Bit1.1 switchCW
22[General] Welcome Greeting - Line 1Text to Show On the Display at Line 114 BytesCW
23[General] Welcome Greeting - Line 2Text to Show On the Display at Line 214 BytesCW
24[General] Welcome Greeting - Line 3Text to Show On the Display at Line 314 BytesCW
25[General] Welcome Greeting - Line 4Text to Show On the Display at Line 414 BytesCW
26[General] Translations - Select Language0 = Main; 1 = Lang. 2; ...; 4 = Lang. 51 ByteCW
27[General] Translations - Main Language0 = Nothing; 1 = Choose this Language1 Bit1.16 acknowledgeCW
28[General] Translations - Language 20 = Nothing; 1 = Choose this Language1 Bit1.16 acknowledgeCW
29[General] Translations - Language 30 = Nothing; 1 = Choose this Language1 Bit1.16 acknowledgeCW
30[General] Translations - Language 40 = Nothing; 1 = Choose this Language1 Bit1.16 acknowledgeCW
31[General] Translations - Language 50 = Nothing; 1 = Choose this Language1 Bit1.16 acknowledgeCW
32[General] Translations - Select LanguageLanguage Selection Through ISO 639-1 Two Letters Code2 Bytes234.1 language code (ASCII)CW
33[General] Sounds - Disabling Button Sound0 = Disable Sound; 1 = Enable Sound1 Bit1.3 enableCW
33[General] Sounds - Disabling Button Sound0 = Enable Sound; 1 = Disable Sound1 Bit1.3 enableCW
34[General] Sounds - Doorbell0 = Play Doorbell Sound; 1 = Nothing1 Bit1.16 acknowledgeCW
34[General] Sounds - Doorbell0 = Nothing; 1 = Play Doorbell Sound1 Bit1.16 acknowledgeCW
35[General] Sounds - Alarm0 = Start Alarm; 1 = Stop Alarm1 Bit1.5 alarmCW
35[General] Sounds - Alarm0 = Stop Alarm; 1 = Start Alarm1 Bit1.5 alarmCW
36[General] Welcome Back ObjectSwitch Object Sent on Wake Up1 Bit1.1 switchCT
37[General] Welcome Back Object - Additional ConditionAdditional Condition Object 11 Bit1.1 switchCW
38[General] Welcome Back Object - Additional ConditionAdditional Condition Object 21 Bit1.1 switchCW
39[General] Welcome Back Object - Additional ConditionAdditional Condition Object 31 Bit1.1 switchCW
40[General] Welcome Back Object - Additional ConditionAdditional Condition Object 41 Bit1.1 switchCW
41[General] Welcome Back Object - Additional ConditionAdditional Condition Object 51 Bit1.1 switchCW
42[General] Temperature Scale0 = ºC; 1 = ºF1 Bit1.1 switchCWTU
43[Btn][I1] Light - On/Off(Short press) Switch between On and Off1 Bit1.1 switchCT
43[Btn][I1] Shutter - Stop/Step(Short press) 0 = Stop shutter/Step up; 1 = Stop shutter/Step down1 Bit1.7 stepCT
43[Btn][I1] Shutter - Stop(End pressing) Stop shutter1 Bit1.17 triggerCT
43[Btn][I1] Switch: "0"1-Bit Generic Control1 Bit1.1 switchCWT
43[Btn][I1] Switch: "1"1-Bit Generic Control1 Bit1.1 switchCWT
43[Btn][I1] Switch: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
43[Btn][I1] Hold & Release1-Bit Generic Control1 Bit1.1 switchCWT
43[Btn][I1] Two Objects - Short Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
43[Btn][I1] Two Objects - Short Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
43[Btn][I1] Two Objects - Short Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
43[Btn][I1] Fan Control (Type: 1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCT
44[Btn][I1] Shutter - Move(Long press) 0 = Up; 1 = Down1 Bit1.8 up/downCT
44[Btn][I1] Shutter - Move(Start pressing) Switch between up and down1 Bit1.8 up/downCT
44[Btn][I1] Two Objects - Long Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
44[Btn][I1] Two Objects - Long Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
44[Btn][I1] Two Objects - Long Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
44[Btn][I1] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.1 switchCWT
44[Btn][I1] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.1 switchCWT
45[Btn][I1] LED On/Off0 = Off; 1 = On1 Bit1.1 switchCWT
45[Btn][I1] LED On/Off0 = On; 1 = Off1 Bit1.1 switchCWT
46[Btn][I1] Light - Dimming(Long press) Switch between dimming up and down4 Bit3.7 dimming controlCWT
47[Btn][I1] EnumerationRotating value change1 Byte5.10 counter pulses (0..255)CWT
47[Btn][I1] Shutter Position0 - 100 %1 Byte5.1 percentage (0..100%)CWT
47[Btn][I1] Light Dimming (Status)0 - 100 %1 Byte5.1 percentage (0..100%)CWT
47[Btn][I1] 1-Byte Unsigned Int Value0 ... 2551 Byte5.10 counter pulses (0..255)CWT
47[Btn][I1] 1-Byte Signed Int Value-128 ... 1271 Byte6.10 counter pulses (-128..127)CWT
47[Btn][I1] Two Objects - Short Press: (1-Byte)Send Selected 1-Byte Value on Short Press1 Byte5.10 counter pulses (0..255)CWT
47[Btn][I1] 1-Byte Scaling Value0% ... 100%1 Byte5.1 percentage (0..100%)CWT
47[Btn][I1] Fan Control (Type: Scaling)100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Enumeration)11 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)1, 21 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)1, 2, 31 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)0, 11 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)0, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)0, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)0, 1, 2, 31 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)0, 1, 21 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CT
47[Btn][I1] Fan Control (Type: Enumeration)Auto, 11 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)Auto, 1, 21 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)Auto, 1, 2, 31 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
47[Btn][I1] Scene: Send0-63 (Run Scene 1-64)1 Byte17.1 scene numberCWT
47[Btn][I1] Scene: Send0-63/128-191 (Run/Save Scene 1-64)1 Byte18.1 scene controlCWT
47[Btn][I1] Room State0 = Normal; 1 = Make-up room; 2 = Do not disturb1 ByteCWT
48[Btn][I1] Two Objects - Long Press: (1-Byte)Send Selected 1-Byte Value on Long Press1 Byte5.10 counter pulses (0..255)CWT
48[Btn][I1] Fan Indicator0% ... 100%1 Byte5.1 percentage (0..100%)CWT
48[Btn][I1] Fan IndicatorEnumerated Value1 Byte5.100 fan stage (0..255)CWT
49[Btn][I1] 2-Byte Unsigned Int Value0 ... 655352 Bytes7.1 pulsesCWT
49[Btn][I1] 2-Byte Signed Int Value-32768 ... 327672 Bytes8.1 pulses differenceCWT
49[Btn][I1] 2-Byte Float Value-671088.64 ... 670760.962 BytesDPT.9CWT
50[Btn][I2] Switch: "0"1-Bit Generic Control1 Bit1.1 switchCWT
50[Btn][I2] Switch: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
50[Btn][I2] Switch: "1"1-Bit Generic Control1 Bit1.1 switchCWT
50[Btn][I2] Hold & Release1-Bit Generic Control1 Bit1.1 switchCWT
50[Btn][I2] Two Objects - Short Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
50[Btn][I2] Two Objects - Short Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
50[Btn][I2] Two Objects - Short Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
50[Btn][I2] Light - On/Off(Short press) Switch between On and Off1 Bit1.1 switchCT
50[Btn][I2] Shutter - Stop/Step(Short press) 0 = Stop shutter/Step up; 1 = Stop shutter/Step down1 Bit1.7 stepCT
50[Btn][I2] Shutter - Stop(End pressing) Stop shutter1 Bit1.17 triggerCT
50[Btn][I2] Fan Control (Type: 1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCT
51[Btn][I2] Two Objects - Long Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
51[Btn][I2] Two Objects - Long Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
51[Btn][I2] Two Objects - Long Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
51[Btn][I2] Shutter - Move(Long press) 0 = Up; 1 = Down1 Bit1.8 up/downCT
51[Btn][I2] Shutter - Move(Start pressing) Switch between up and down1 Bit1.8 up/downCT
51[Btn][I2] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.1 switchCWT
51[Btn][I2] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.1 switchCWT
52[Btn][I2] LED On/Off0 = Off; 1 = On1 Bit1.1 switchCWT
52[Btn][I2] LED On/Off0 = On; 1 = Off1 Bit1.1 switchCWT
53[Btn][I2] Light - Dimming(Long press) Switch between dimming up and down4 Bit3.7 dimming controlCWT
54[Btn][I2] Two Objects - Short Press: (1-Byte)Send Selected 1-Byte Value on Short Press1 Byte5.10 counter pulses (0..255)CWT
54[Btn][I2] Scene: Send0-63 (Run Scene 1-64)1 Byte17.1 scene numberCWT
54[Btn][I2] Scene: Send0-63/128-191 (Run/Save Scene 1-64)1 Byte18.1 scene controlCWT
54[Btn][I2] 1-Byte Scaling Value0% ... 100%1 Byte5.1 percentage (0..100%)CWT
54[Btn][I2] 1-Byte Unsigned Int Value0 ... 2551 Byte5.10 counter pulses (0..255)CWT
54[Btn][I2] 1-Byte Signed Int Value-128 ... 1271 Byte6.10 counter pulses (-128..127)CWT
54[Btn][I2] Light Dimming (Status)0 - 100 %1 Byte5.1 percentage (0..100%)CWT
54[Btn][I2] Shutter Position0 - 100 %1 Byte5.1 percentage (0..100%)CWT
54[Btn][I2] EnumerationRotating value change1 Byte5.10 counter pulses (0..255)CWT
54[Btn][I2] Fan Control (Type: Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
54[Btn][I2] Fan Control (Type: Enumeration)Auto, 11 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)0, 11 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)11 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)Auto, 1, 21 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)0, 1, 21 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)1, 21 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)Auto, 1, 2, 31 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)0, 1, 2, 31 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)1, 2, 31 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)0, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)0, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Fan Control (Type: Enumeration)1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
54[Btn][I2] Room State0 = Normal; 1 = Make-up room; 2 = Do not disturb1 ByteCWT
55[Btn][I2] Two Objects - Long Press: (1-Byte)Send Selected 1-Byte Value on Long Press1 Byte5.10 counter pulses (0..255)CWT
55[Btn][I2] Fan Indicator0% ... 100%1 Byte5.1 percentage (0..100%)CWT
55[Btn][I2] Fan IndicatorEnumerated Value1 Byte5.100 fan stage (0..255)CWT
56[Btn][I2] 2-Byte Unsigned Int Value0 ... 655352 Bytes7.1 pulsesCWT
56[Btn][I2] 2-Byte Signed Int Value-32768 ... 327672 Bytes8.1 pulses differenceCWT
56[Btn][I2] 2-Byte Float Value-671088.64 ... 670760.962 BytesDPT.9CWT
57[Btn][I3] Switch: "0"1-Bit Generic Control1 Bit1.1 switchCWT
57[Btn][I3] Switch: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
57[Btn][I3] Switch: "1"1-Bit Generic Control1 Bit1.1 switchCWT
57[Btn][I3] Hold & Release1-Bit Generic Control1 Bit1.1 switchCWT
57[Btn][I3] Two Objects - Short Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
57[Btn][I3] Two Objects - Short Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
57[Btn][I3] Two Objects - Short Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
57[Btn][I3] Light - On/Off(Short press) Switch between On and Off1 Bit1.1 switchCT
57[Btn][I3] Shutter - Stop/Step(Short press) 0 = Stop shutter/Step up; 1 = Stop shutter/Step down1 Bit1.7 stepCT
57[Btn][I3] Shutter - Stop(End pressing) Stop shutter1 Bit1.17 triggerCT
57[Btn][I3] Fan Control (Type: 1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCT
58[Btn][I3] Two Objects - Long Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
58[Btn][I3] Two Objects - Long Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
58[Btn][I3] Two Objects - Long Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
58[Btn][I3] Shutter - Move(Long press) 0 = Up; 1 = Down1 Bit1.8 up/downCT
58[Btn][I3] Shutter - Move(Start pressing) Switch between up and down1 Bit1.8 up/downCT
58[Btn][I3] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.1 switchCWT
58[Btn][I3] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.1 switchCWT
59[Btn][I3] LED On/Off0 = Off; 1 = On1 Bit1.1 switchCWT
59[Btn][I3] LED On/Off0 = On; 1 = Off1 Bit1.1 switchCWT
60[Btn][I3] Light - Dimming(Long press) Switch between dimming up and down4 Bit3.7 dimming controlCWT
61[Btn][I3] Two Objects - Short Press: (1-Byte)Send Selected 1-Byte Value on Short Press1 Byte5.10 counter pulses (0..255)CWT
61[Btn][I3] Scene: Send0-63 (Run Scene 1-64)1 Byte17.1 scene numberCWT
61[Btn][I3] Scene: Send0-63/128-191 (Run/Save Scene 1-64)1 Byte18.1 scene controlCWT
61[Btn][I3] 1-Byte Scaling Value0% ... 100%1 Byte5.1 percentage (0..100%)CWT
61[Btn][I3] 1-Byte Unsigned Int Value0 ... 2551 Byte5.10 counter pulses (0..255)CWT
61[Btn][I3] 1-Byte Signed Int Value-128 ... 1271 Byte6.10 counter pulses (-128..127)CWT
61[Btn][I3] Light Dimming (Status)0 - 100 %1 Byte5.1 percentage (0..100%)CWT
61[Btn][I3] Shutter Position0 - 100 %1 Byte5.1 percentage (0..100%)CWT
61[Btn][I3] EnumerationRotating value change1 Byte5.10 counter pulses (0..255)CWT
61[Btn][I3] Fan Control (Type: Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
61[Btn][I3] Fan Control (Type: Enumeration)Auto, 11 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)0, 11 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)11 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)Auto, 1, 21 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)0, 1, 21 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)1, 21 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)Auto, 1, 2, 31 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)0, 1, 2, 31 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)1, 2, 31 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)0, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)0, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Fan Control (Type: Enumeration)1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
61[Btn][I3] Room State0 = Normal; 1 = Make-up room; 2 = Do not disturb1 ByteCWT
62[Btn][I3] Two Objects - Long Press: (1-Byte)Send Selected 1-Byte Value on Long Press1 Byte5.10 counter pulses (0..255)CWT
62[Btn][I3] Fan Indicator0% ... 100%1 Byte5.1 percentage (0..100%)CWT
62[Btn][I3] Fan IndicatorEnumerated Value1 Byte5.100 fan stage (0..255)CWT
63[Btn][I3] 2-Byte Unsigned Int Value0 ... 655352 Bytes7.1 pulsesCWT
63[Btn][I3] 2-Byte Signed Int Value-32768 ... 327672 Bytes8.1 pulses differenceCWT
63[Btn][I3] 2-Byte Float Value-671088.64 ... 670760.962 BytesDPT.9CWT
64[Btn][I4] Switch: "0"1-Bit Generic Control1 Bit1.1 switchCWT
64[Btn][I4] Switch: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
64[Btn][I4] Switch: "1"1-Bit Generic Control1 Bit1.1 switchCWT
64[Btn][I4] Hold & Release1-Bit Generic Control1 Bit1.1 switchCWT
64[Btn][I4] Two Objects - Short Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
64[Btn][I4] Two Objects - Short Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
64[Btn][I4] Two Objects - Short Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
64[Btn][I4] Light - On/Off(Short press) Switch between On and Off1 Bit1.1 switchCT
64[Btn][I4] Shutter - Stop/Step(Short press) 0 = Stop shutter/Step up; 1 = Stop shutter/Step down1 Bit1.7 stepCT
64[Btn][I4] Shutter - Stop(End pressing) Stop shutter1 Bit1.17 triggerCT
64[Btn][I4] Fan Control (Type: 1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCT
65[Btn][I4] Two Objects - Long Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
65[Btn][I4] Two Objects - Long Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
65[Btn][I4] Two Objects - Long Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
65[Btn][I4] Shutter - Move(Long press) 0 = Up; 1 = Down1 Bit1.8 up/downCT
65[Btn][I4] Shutter - Move(Start pressing) Switch between up and down1 Bit1.8 up/downCT
65[Btn][I4] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.1 switchCWT
65[Btn][I4] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.1 switchCWT
66[Btn][I4] LED On/Off0 = Off; 1 = On1 Bit1.1 switchCWT
66[Btn][I4] LED On/Off0 = On; 1 = Off1 Bit1.1 switchCWT
67[Btn][I4] Light - Dimming(Long press) Switch between dimming up and down4 Bit3.7 dimming controlCWT
68[Btn][I4] Two Objects - Short Press: (1-Byte)Send Selected 1-Byte Value on Short Press1 Byte5.10 counter pulses (0..255)CWT
68[Btn][I4] Scene: Send0-63 (Run Scene 1-64)1 Byte17.1 scene numberCWT
68[Btn][I4] Scene: Send0-63/128-191 (Run/Save Scene 1-64)1 Byte18.1 scene controlCWT
68[Btn][I4] 1-Byte Scaling Value0% ... 100%1 Byte5.1 percentage (0..100%)CWT
68[Btn][I4] 1-Byte Unsigned Int Value0 ... 2551 Byte5.10 counter pulses (0..255)CWT
68[Btn][I4] 1-Byte Signed Int Value-128 ... 1271 Byte6.10 counter pulses (-128..127)CWT
68[Btn][I4] Light Dimming (Status)0 - 100 %1 Byte5.1 percentage (0..100%)CWT
68[Btn][I4] Shutter Position0 - 100 %1 Byte5.1 percentage (0..100%)CWT
68[Btn][I4] EnumerationRotating value change1 Byte5.10 counter pulses (0..255)CWT
68[Btn][I4] Fan Control (Type: Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
68[Btn][I4] Fan Control (Type: Enumeration)Auto, 11 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)0, 11 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)11 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)Auto, 1, 21 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)0, 1, 21 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)1, 21 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)Auto, 1, 2, 31 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)0, 1, 2, 31 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)1, 2, 31 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)0, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)0, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Fan Control (Type: Enumeration)1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
68[Btn][I4] Room State0 = Normal; 1 = Make-up room; 2 = Do not disturb1 ByteCWT
69[Btn][I4] Two Objects - Long Press: (1-Byte)Send Selected 1-Byte Value on Long Press1 Byte5.10 counter pulses (0..255)CWT
69[Btn][I4] Fan Indicator0% ... 100%1 Byte5.1 percentage (0..100%)CWT
69[Btn][I4] Fan IndicatorEnumerated Value1 Byte5.100 fan stage (0..255)CWT
70[Btn][I4] 2-Byte Unsigned Int Value0 ... 655352 Bytes7.1 pulsesCWT
70[Btn][I4] 2-Byte Signed Int Value-32768 ... 327672 Bytes8.1 pulses differenceCWT
70[Btn][I4] 2-Byte Float Value-671088.64 ... 670760.962 BytesDPT.9CWT
71[Btn][I5] Switch: "0"1-Bit Generic Control1 Bit1.1 switchCWT
71[Btn][I5] Switch: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
71[Btn][I5] Switch: "1"1-Bit Generic Control1 Bit1.1 switchCWT
71[Btn][I5] Hold & Release1-Bit Generic Control1 Bit1.1 switchCWT
71[Btn][I5] Two Objects - Short Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
71[Btn][I5] Two Objects - Short Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
71[Btn][I5] Two Objects - Short Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
71[Btn][I5] Light - On/Off(Short press) Switch between On and Off1 Bit1.1 switchCT
71[Btn][I5] Shutter - Stop/Step(Short press) 0 = Stop shutter/Step up; 1 = Stop shutter/Step down1 Bit1.7 stepCT
71[Btn][I5] Shutter - Stop(End pressing) Stop shutter1 Bit1.17 triggerCT
71[Btn][I5] Fan Control (Type: 1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCT
72[Btn][I5] Two Objects - Long Press: "0"1-Bit Generic Control1 Bit1.1 switchCWT
72[Btn][I5] Two Objects - Long Press: "1"1-Bit Generic Control1 Bit1.1 switchCWT
72[Btn][I5] Two Objects - Long Press: "0/1"1-Bit Generic Control1 Bit1.1 switchCWT
72[Btn][I5] Shutter - Move(Long press) 0 = Up; 1 = Down1 Bit1.8 up/downCT
72[Btn][I5] Shutter - Move(Start pressing) Switch between up and down1 Bit1.8 up/downCT
72[Btn][I5] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.1 switchCWT
72[Btn][I5] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.1 switchCWT
73[Btn][I5] LED On/Off0 = Off; 1 = On1 Bit1.1 switchCWT
73[Btn][I5] LED On/Off0 = On; 1 = Off1 Bit1.1 switchCWT
74[Btn][I5] Light - Dimming(Long press) Switch between dimming up and down4 Bit3.7 dimming controlCWT
75[Btn][I5] Two Objects - Short Press: (1-Byte)Send Selected 1-Byte Value on Short Press1 Byte5.10 counter pulses (0..255)CWT
75[Btn][I5] Scene: Send0-63 (Run Scene 1-64)1 Byte17.1 scene numberCWT
75[Btn][I5] Scene: Send0-63/128-191 (Run/Save Scene 1-64)1 Byte18.1 scene controlCWT
75[Btn][I5] 1-Byte Scaling Value0% ... 100%1 Byte5.1 percentage (0..100%)CWT
75[Btn][I5] 1-Byte Unsigned Int Value0 ... 2551 Byte5.10 counter pulses (0..255)CWT
75[Btn][I5] 1-Byte Signed Int Value-128 ... 1271 Byte6.10 counter pulses (-128..127)CWT
75[Btn][I5] Light Dimming (Status)0 - 100 %1 Byte5.1 percentage (0..100%)CWT
75[Btn][I5] Shutter Position0 - 100 %1 Byte5.1 percentage (0..100%)CWT
75[Btn][I5] EnumerationRotating value change1 Byte5.10 counter pulses (0..255)CWT
75[Btn][I5] Fan Control (Type: Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
75[Btn][I5] Fan Control (Type: Enumeration)Auto, 11 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)0, 11 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)11 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)Auto, 1, 21 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)0, 1, 21 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)1, 21 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)Auto, 1, 2, 31 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)0, 1, 2, 31 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)1, 2, 31 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)0, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)0, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Fan Control (Type: Enumeration)1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
75[Btn][I5] Room State0 = Normal; 1 = Make-up room; 2 = Do not disturb1 ByteCWT
76[Btn][I5] Two Objects - Long Press: (1-Byte)Send Selected 1-Byte Value on Long Press1 Byte5.10 counter pulses (0..255)CWT
76[Btn][I5] Fan Indicator0% ... 100%1 Byte5.1 percentage (0..100%)CWT
76[Btn][I5] Fan IndicatorEnumerated Value1 Byte5.100 fan stage (0..255)CWT
77[Btn][I5] 2-Byte Unsigned Int Value0 ... 655352 Bytes7.1 pulsesCWT
77[Btn][I5] 2-Byte Signed Int Value-32768 ... 327672 Bytes8.1 pulses differenceCWT
77[Btn][I5] 2-Byte Float Value-671088.64 ... 670760.962 BytesDPT.9CWT
78[Btn][PA] SwitchLeft = 0; Right = 11 Bit1.1 switchCWT
78[Btn][PA] Two Objects - Short pressLeft = 1; Right = 01 Bit1.1 switchCWT
78[Btn][PA] Two Objects - Short pressLeft = 0; Right = 11 Bit1.1 switchCWT
78[Btn][PA] Light - On/Off(Short press) Left = Off; Right = On1 Bit1.1 switchCT
78[Btn][PA] Shutter - Stop/Step(Short press) Left = Stop/Step down; Right = Stop/Step up1 Bit1.7 stepCT
78[Btn][PA] Shutter - Stop(End pressing) Left = Stop-down; Right = Stop-up1 Bit1.17 triggerCT
78[Btn][PA] (Climate) ModeLeft = Cool; Right = Heat1 Bit1.100 cooling/heatingCWT
78[Btn][PA] SwitchLeft = 1; Right = 01 Bit1.1 switchCWT
78[Btn][PA] Light - On/Off(Short press) Left = On; Right = Off1 Bit1.1 switchCT
78[Btn][PA] Shutter - Stop/Step(Short press) Left = Stop/Step up; Right = Stop/Step down1 Bit1.7 stepCT
78[Btn][PA] Shutter - Stop(End pressing) Left = Stop-up; Right = Stop-down1 Bit1.17 triggerCT
78[Btn][PA] MultimediaLeft = Stop/Backward; Right = Start/Forward1 Bit1.1 switchCWT
78[Btn][PA] MultimediaLeft = Start/Forward; Right = Stop/Backward1 Bit1.1 switchCWT
78[Btn][PA] Fan Control (Type: 1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCT
79[Btn][PA] Two Objects - Long pressLeft = 0; Right = 11 Bit1.1 switchCWT
79[Btn][PA] Two Objects - Long pressLeft = 1; Right = 01 Bit1.1 switchCWT
79[Btn][PA] Shutter - Move(Long press) Left = Down; Right = Up1 Bit1.8 up/downCT
79[Btn][PA] Shutter - Move(Start pressing) Left = Down; Right = Up1 Bit1.8 up/downCT
79[Btn][PA] Shutter - Move(Long press) Left = Up; Right = Down1 Bit1.8 up/downCT
79[Btn][PA] Shutter - Move(Start pressing) Left = Up; Right = Down1 Bit1.8 up/downCT
79[Btn][PA] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.1 switchCWT
79[Btn][PA] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.1 switchCWT
80[Btn][PA] LED On/Off0 = On; 1 = Off1 Bit1.1 switchCWT
80[Btn][PA] LED On/Off0 = Off; 1 = On1 Bit1.1 switchCWT
81[Btn][PA] Light - Dimming(Long press) Left = Darker; Right = Brighter4 Bit3.7 dimming controlCWT
81[Btn][PA] Light - Dimming(Long press) Left = Brighter; Right = Darker4 Bit3.7 dimming controlCWT
82[Btn][PA] ScalingLeft = Decrease percentage; Right = Increase percent.1 Byte5.1 percentage (0..100%)CWT
82[Btn][PA] ScalingLeft = Increase percentage; Right = Decrease percent.1 Byte5.1 percentage (0..100%)CWT
82[Btn][PA] Counter - 1-Byte unsignedLeft = Decrease; Right = Increase1 Byte5.10 counter pulses (0..255)CWT
82[Btn][PA] Counter - 1-Byte unsignedLeft = Increase; Right = Decrease1 Byte5.10 counter pulses (0..255)CWT
82[Btn][PA] EnumerationRotating value change on short press1 Byte5.10 counter pulses (0..255)CWT
82[Btn][PA] (Climate) Mode - ExtendedRotating change of selected modes on short press1 Byte20.105 HVAC control modeCWT
82[Btn][PA] Counter - 1-Byte signedLeft = Decrease; Right = Increase1 Byte6.10 counter pulses (-128..127)CWT
82[Btn][PA] Counter - 1-Byte signedLeft = Increase; Right = Decrease1 Byte6.10 counter pulses (-128..127)CWT
82[Btn][PA] Light Dimming (Status)0 - 100 %1 Byte5.1 percentage (0..100%)CWT
82[Btn][PA] Fan Control (Type: Scaling)100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Enumeration)11 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)1, 21 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)1, 2, 31 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
82[Btn][PA] (Climate) Special Mode ControlAuto, Comfort, Standby, Economy, Building Protection1 Byte20.102 HVAC modeCWT
82[Btn][PA] Fan Control (Type: Enumeration)0, 11 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)0, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)0, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)0, 1, 2, 31 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)0, 1, 21 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CT
82[Btn][PA] Fan Control (Type: Enumeration)Auto, 11 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)Auto, 1, 21 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)Auto, 1, 2, 31 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
82[Btn][PA] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
83[Btn][PA] Fan Indicator0% ... 100%1 Byte5.1 percentage (0..100%)CWT
83[Btn][PA] Fan IndicatorEnumerated Value1 Byte5.100 fan stage (0..255)CWT
84[Btn][PA] Counter - 2-Byte signedLeft = Decrease; Right = Increase2 Bytes8.1 pulses differenceCWT
84[Btn][PA] Counter - 2-Byte signedLeft = Increase; Right = Decrease2 Bytes8.1 pulses differenceCWT
84[Btn][PA] FloatLeft = Decrease; Right = Increase2 BytesDPT.9CWT
84[Btn][PA] FloatLeft = Increase; Right = Decrease2 BytesDPT.9CWT
84[Btn][PA] (Climate) Temperature setpointLeft = Decrease; Right = Increase2 Bytes9.1 temperature (°C)CWT
84[Btn][PA] (Climate) Temperature setpointLeft = Increase; Right = Decrease2 Bytes9.1 temperature (°C)CWT
84[Btn][PA] Counter - 2-Byte unsignedLeft = Decrease; Right = Increase2 Bytes7.1 pulsesCWT
84[Btn][PA] Counter - 2-Byte unsignedLeft = Increase; Right = Decrease2 Bytes7.1 pulsesCWT
85[Btn][PB] SwitchLeft = 0; Right = 11 Bit1.1 switchCWT
85[Btn][PB] SwitchLeft = 1; Right = 01 Bit1.1 switchCWT
85[Btn][PB] Light - On/Off(Short press) Left = Off; Right = On1 Bit1.1 switchCT
85[Btn][PB] Light - On/Off(Short press) Left = On; Right = Off1 Bit1.1 switchCT
85[Btn][PB] Shutter - Stop/Step(Short press) Left = Stop/Step down; Right = Stop/Step up1 Bit1.7 stepCT
85[Btn][PB] Shutter - Stop/Step(Short press) Left = Stop/Step up; Right = Stop/Step down1 Bit1.7 stepCT
85[Btn][PB] Shutter - Stop(End pressing) Left = Stop-down; Right = Stop-up1 Bit1.17 triggerCT
85[Btn][PB] Shutter - Stop(End pressing) Left = Stop-up; Right = Stop-down1 Bit1.17 triggerCT
85[Btn][PB] Two Objects - Short pressLeft = 0; Right = 11 Bit1.1 switchCWT
85[Btn][PB] Two Objects - Short pressLeft = 1; Right = 01 Bit1.1 switchCWT
85[Btn][PB] MultimediaLeft = Stop/Backward; Right = Start/Forward1 Bit1.1 switchCWT
85[Btn][PB] MultimediaLeft = Start/Forward; Right = Stop/Backward1 Bit1.1 switchCWT
85[Btn][PB] (Climate) ModeLeft = Cool; Right = Heat1 Bit1.100 cooling/heatingCWT
85[Btn][PB] Fan Control (Type: 1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCT
86[Btn][PB] Shutter - Move(Long press) Left = Down; Right = Up1 Bit1.8 up/downCT
86[Btn][PB] Shutter - Move(Long press) Left = Up; Right = Down1 Bit1.8 up/downCT
86[Btn][PB] Shutter - Move(Start pressing) Left = Down; Right = Up1 Bit1.8 up/downCT
86[Btn][PB] Shutter - Move(Start pressing) Left = Up; Right = Down1 Bit1.8 up/downCT
86[Btn][PB] Two Objects - Long pressLeft = 0; Right = 11 Bit1.1 switchCWT
86[Btn][PB] Two Objects - Long pressLeft = 1; Right = 01 Bit1.1 switchCWT
86[Btn][PB] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.1 switchCWT
86[Btn][PB] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.1 switchCWT
87[Btn][PB] LED On/Off0 = Off; 1 = On1 Bit1.1 switchCWT
87[Btn][PB] LED On/Off0 = On; 1 = Off1 Bit1.1 switchCWT
88[Btn][PB] Light - Dimming(Long press) Left = Darker; Right = Brighter4 Bit3.7 dimming controlCWT
88[Btn][PB] Light - Dimming(Long press) Left = Brighter; Right = Darker4 Bit3.7 dimming controlCWT
89[Btn][PB] ScalingLeft = Decrease percentage; Right = Increase percent.1 Byte5.1 percentage (0..100%)CWT
89[Btn][PB] ScalingLeft = Increase percentage; Right = Decrease percent.1 Byte5.1 percentage (0..100%)CWT
89[Btn][PB] Counter - 1-Byte unsignedLeft = Decrease; Right = Increase1 Byte5.10 counter pulses (0..255)CWT
89[Btn][PB] Counter - 1-Byte unsignedLeft = Increase; Right = Decrease1 Byte5.10 counter pulses (0..255)CWT
89[Btn][PB] Counter - 1-Byte signedLeft = Decrease; Right = Increase1 Byte6.10 counter pulses (-128..127)CWT
89[Btn][PB] Counter - 1-Byte signedLeft = Increase; Right = Decrease1 Byte6.10 counter pulses (-128..127)CWT
89[Btn][PB] EnumerationRotating value change on short press1 Byte5.10 counter pulses (0..255)CWT
89[Btn][PB] (Climate) Mode - ExtendedRotating change of selected modes on short press1 Byte20.105 HVAC control modeCWT
89[Btn][PB] Fan Control (Type: Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CT
89[Btn][PB] Fan Control (Type: Enumeration)Auto, 11 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)0, 11 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)11 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)Auto, 1, 21 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)0, 1, 21 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)1, 21 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)Auto, 1, 2, 31 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)0, 1, 2, 31 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)1, 2, 31 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)0, 1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)1, 2, 3, 41 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)Auto, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)0, 1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
89[Btn][PB] Fan Control (Type: Enumeration)1, 2, 3, 4, 51 Byte5.100 fan stage (0..255)CT
89[Btn][PB] (Climate) Special Mode ControlAuto, Comfort, Standby, Economy, Building Protection1 Byte20.102 HVAC modeCWT
89[Btn][PB] Light Dimming (Status)0 - 100 %1 Byte5.1 percentage (0..100%)CWT
90[Btn][PB] Fan Indicator0% ... 100%1 Byte5.1 percentage (0..100%)CWT
90[Btn][PB] Fan IndicatorEnumerated Value1 Byte5.100 fan stage (0..255)CWT
91[Btn][PB] Counter - 2-Byte unsignedLeft = Decrease; Right = Increase2 Bytes7.1 pulsesCWT
91[Btn][PB] Counter - 2-Byte unsignedLeft = Increase; Right = Decrease2 Bytes7.1 pulsesCWT
91[Btn][PB] Counter - 2-Byte signedLeft = Decrease; Right = Increase2 Bytes8.1 pulses differenceCWT
91[Btn][PB] Counter - 2-Byte signedLeft = Increase; Right = Decrease2 Bytes8.1 pulses differenceCWT
91[Btn][PB] FloatLeft = Decrease; Right = Increase2 BytesDPT.9CWT
91[Btn][PB] FloatLeft = Increase; Right = Decrease2 BytesDPT.9CWT
91[Btn][PB] (Climate) Temperature setpointLeft = Decrease; Right = Increase2 Bytes9.1 temperature (°C)CWT
91[Btn][PB] (Climate) Temperature setpointLeft = Increase; Right = Decrease2 Bytes9.1 temperature (°C)CWT
92[Disp][A] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
92[Disp][A1] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
93[Disp][A] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
93[Disp][A] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
93[Disp][A] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
93[Disp][A] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
93[Disp][A1] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
93[Disp][A1] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
93[Disp][A1] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
93[Disp][A1] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
94[Disp][A] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
94[Disp][A1] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
95[Disp][A] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
95[Disp][A1] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
96[Disp][A] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
96[Disp][A] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
96[Disp][A] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
96[Disp][A] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
96[Disp][A] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A1] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
96[Disp][A] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
96[Disp][A1] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A1] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A1] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
96[Disp][A1] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
96[Disp][A1] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A1] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
96[Disp][A1] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
96[Disp][A1] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A1] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A1] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
96[Disp][A1] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
96[Disp][A] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
97[Disp][A] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
97[Disp][A] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
97[Disp][A] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
97[Disp][A] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
97[Disp][A1] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
97[Disp][A1] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
97[Disp][A1] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
97[Disp][A1] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
98[Disp][A] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
98[Disp][A] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
98[Disp][A1] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
98[Disp][A1] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
99[Disp][A] Text from objectReceived text is shown14 BytesCWTU
99[Disp][A1] Text from objectReceived text is shown14 BytesCWTU
100[Disp][A2] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
101[Disp][A2] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
101[Disp][A2] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
101[Disp][A2] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
101[Disp][A2] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
102[Disp][A2] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
103[Disp][A2] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
104[Disp][A2] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
104[Disp][A2] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
104[Disp][A2] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
104[Disp][A2] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
104[Disp][A2] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
104[Disp][A2] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
104[Disp][A2] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
104[Disp][A2] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
104[Disp][A2] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
104[Disp][A2] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
104[Disp][A2] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
104[Disp][A2] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
105[Disp][A2] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
105[Disp][A2] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
105[Disp][A2] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
105[Disp][A2] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
106[Disp][A2] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
106[Disp][A2] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
107[Disp][A2] Text from objectReceived text is shown14 BytesCWTU
108[Disp][B] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
108[Disp][B1] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
108[Disp][Setpoint] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
109[Disp][B] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
109[Disp][B] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
109[Disp][B] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
109[Disp][B] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
109[Disp][B1] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
109[Disp][B1] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
109[Disp][B1] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
109[Disp][B1] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
110[Disp][B] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
110[Disp][B1] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
111[Disp][B] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
111[Disp][B1] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
112[Disp][B] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
112[Disp][B] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
112[Disp][B] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
112[Disp][B] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
112[Disp][B] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
112[Disp][B] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
112[Disp][B1] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
112[Disp][B1] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B1] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
112[Disp][B1] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
112[Disp][B1] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
112[Disp][B1] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
112[Disp][B1] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B1] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B1] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B1] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B1] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
112[Disp][B1] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
113[Disp][B] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
113[Disp][B] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
113[Disp][B] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
113[Disp][B] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
113[Disp][B1] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
113[Disp][B1] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
113[Disp][B1] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
113[Disp][B1] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
113[Disp][Setpoint] Real Temperature-99ºC ... 199ºC2 Bytes9.1 temperature (°C)CWTU
113[Disp][Setpoint] Setpoint Temperature-99ºC ... 199ºC2 Bytes9.1 temperature (°C)CWTU
114[Disp][B] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
114[Disp][B] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
114[Disp][B1] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
114[Disp][B1] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
115[Disp][B] Text from objectReceived text is shown14 BytesCWTU
115[Disp][B1] Text from objectReceived text is shown14 BytesCWTU
116[Disp][B2] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
117[Disp][B2] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
117[Disp][B2] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
117[Disp][B2] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
117[Disp][B2] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
118[Disp][B2] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
119[Disp][B2] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
120[Disp][B2] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
120[Disp][B2] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
120[Disp][B2] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
120[Disp][B2] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
120[Disp][B2] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
120[Disp][B2] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
120[Disp][B2] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
120[Disp][B2] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
120[Disp][B2] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
120[Disp][B2] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
120[Disp][B2] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
120[Disp][B2] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
121[Disp][B2] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
121[Disp][B2] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
121[Disp][B2] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
121[Disp][B2] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
121[Disp][Setpoint] Setpoint Temperature-99ºC ... 199ºC2 Bytes9.1 temperature (°C)CWTU
121[Disp][Setpoint] Real Temperature-99ºC ... 199ºC2 Bytes9.1 temperature (°C)CWTU
122[Disp][B2] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
122[Disp][B2] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
123[Disp][B2] Text from objectReceived text is shown14 BytesCWTU
124[Disp][C] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
124[Disp][C1] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
124[Disp][Fan] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
125[Disp][C] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
125[Disp][C] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
125[Disp][C] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
125[Disp][C] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
125[Disp][C1] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
125[Disp][C1] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
125[Disp][C1] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
125[Disp][C1] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
125[Disp][Fan] Auto Mode ValueAuto Mode With 01 Bit1.1 switchCWTU
125[Disp][Fan] Auto Mode ValueAuto Mode With 11 Bit1.1 switchCWTU
126[Disp][C] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
126[Disp][C1] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
127[Disp][C] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
127[Disp][C1] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
128[Disp][C] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
128[Disp][C] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
128[Disp][C] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
128[Disp][C] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
128[Disp][C] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
128[Disp][C] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
128[Disp][C1] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
128[Disp][C1] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C1] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
128[Disp][C1] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
128[Disp][C1] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
128[Disp][C1] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
128[Disp][C1] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C1] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C1] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C1] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C1] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][C1] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
128[Disp][Fan] Fan Indicator3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][Fan] Fan Indicator2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][Fan] Fan IndicatorAuto + 3 levels: Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
128[Disp][Fan] Fan IndicatorAuto + 2 levels: Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
129[Disp][C] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
129[Disp][C] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
129[Disp][C] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
129[Disp][C] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
129[Disp][C1] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
129[Disp][C1] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
129[Disp][C1] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
129[Disp][C1] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
130[Disp][C] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
130[Disp][C] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
130[Disp][C1] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
130[Disp][C1] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
131[Disp][C] Text from objectReceived text is shown14 BytesCWTU
131[Disp][C1] Text from objectReceived text is shown14 BytesCWTU
132[Disp][C2] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
133[Disp][C2] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
133[Disp][C2] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
133[Disp][C2] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
133[Disp][C2] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
134[Disp][C2] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
135[Disp][C2] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
136[Disp][C2] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
136[Disp][C2] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
136[Disp][C2] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
136[Disp][C2] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
136[Disp][C2] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
136[Disp][C2] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
136[Disp][C2] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
136[Disp][C2] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
136[Disp][C2] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
136[Disp][C2] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
136[Disp][C2] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
136[Disp][C2] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
137[Disp][C2] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
137[Disp][C2] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
137[Disp][C2] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
137[Disp][C2] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
138[Disp][C2] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
138[Disp][C2] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
139[Disp][C2] Text from objectReceived text is shown14 BytesCWTU
140[Disp][D] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
140[Disp][D1] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
141[Disp][D] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
141[Disp][D] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
141[Disp][D] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
141[Disp][D] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
141[Disp][D1] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
141[Disp][D1] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
141[Disp][D1] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
141[Disp][D1] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
141[Disp] Alarm Enable0 = Disable; 1 = Enable1 Bit1.3 enableCW
141[Disp] Alarm Enable0 = Enable; 1 = Disable1 Bit1.3 enableCW
142[Disp][D] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
142[Disp][D1] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
142[Disp] Alarm0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCWTU
142[Disp] Alarm0 = Alarm; 1 = No Alarm1 Bit1.5 alarmCWTU
143[Disp][D] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
143[Disp][D1] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
144[Disp][D] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
144[Disp][D] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
144[Disp][D] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
144[Disp][D] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
144[Disp][D] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
144[Disp][D] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
144[Disp][D1] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
144[Disp][D1] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D1] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
144[Disp][D1] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
144[Disp][D1] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
144[Disp][D1] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
144[Disp][D1] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D1] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D1] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D1] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D1] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
144[Disp][D1] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
145[Disp][D] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
145[Disp][D] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
145[Disp][D] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
145[Disp][D] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
145[Disp][D1] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
145[Disp][D1] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
145[Disp][D1] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
145[Disp][D1] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
146[Disp][D] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
146[Disp][D] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
146[Disp][D1] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
146[Disp][D1] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
147[Disp][D] Text from objectReceived text is shown14 BytesCWTU
147[Disp][D1] Text from objectReceived text is shown14 BytesCWTU
148[Disp][D2] Show/Hide Box0 = Hide Box; 1 = Show Box1 Bit1.1 switchCW
149[Disp][D2] Icon - 1-BitSelected icon shown on new value reception1 Bit1.1 switchCWTU
149[Disp][D2] Text - 1-BitParameterized text shown on new value reception1 Bit1.1 switchCWTU
149[Disp][D2] (Climate) ModeMode Indicator Is Shown (0 = Cool; 1 = Heat)1 Bit1.100 cooling/heatingCWTU
149[Disp][D2] (Climate) On/Off0 = Off (hide indicator); 1 = On (show mode or status)1 Bit1.1 switchCWTU
149[Disp][Setpoint] Thermostat State0 = Off; 1 = On1 Bit1.1 switchCWTU
150[Disp][D2] (Climate) On/Off - Mode0 = Cool; 1 = Heat. (Mode Indicator Is Shown when On/Off = 1, and Status = 0)1 Bit1.100 cooling/heatingCWTU
151[Disp][D2] (Climate) On/Off - Status0 = Halted; 1 = Running. (Status icon is shown when On/Off = 1, and Status = 1)1 Bit1.1 switchCWTU
152[Disp][D2] Icon - EnumerationSelected icon shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
152[Disp][D2] Number - ScalingObject numeric value is shown1 Byte5.1 percentage (0..100%)CWTU
152[Disp][D2] Number - Counter (1-Byte unsigned)Object numeric value is shown1 Byte5.10 counter pulses (0..255)CWTU
152[Disp][D2] Number - Counter (1-Byte signed)Object numeric value is shown1 Byte6.10 counter pulses (-128..127)CWTU
152[Disp][D2] Text - EnumerationParameterized text shown on new value reception1 Byte5.10 counter pulses (0..255)CWTU
152[Disp][D2] (Climate) Mode - ExtendedMode Indicator Is Shown1 Byte20.105 HVAC control modeCWTU
152[Disp][D2] Fan2 levels: Min. (0% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
152[Disp][D2] Fan3 levels: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
152[Disp][D2] FanOff/Auto + 1 level: Off/Auto = 0%; Max. (1% - 100%)1 Byte5.1 percentage (0..100%)CWTU
152[Disp][D2] FanOff/Auto + 2 levels: Off/Auto = 0%; Min. (1% - 50%); Max. (51% - 100%)1 Byte5.1 percentage (0..100%)CWTU
152[Disp][D2] FanOff/Auto + 3 levels: Off/Auto = 0%; Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)1 Byte5.1 percentage (0..100%)CWTU
152[Disp][D2] (Climate) Mode SpecialMode Indicator Is Shown1 Byte20.102 HVAC modeCWTU
153[Disp][D2] Number - Counter (2-Byte unsigned)Object numeric value is shown2 Bytes7.1 pulsesCWTU
153[Disp][D2] Number - Counter (2-Byte signed)Object numeric value is shown2 Bytes8.1 pulses differenceCWTU
153[Disp][D2] Number - Float (2-Byte)Object numeric value is shown2 BytesDPT.9CWTU
153[Disp][D2] (Climate) TemperatureObject value is shown (-99ºC to 199ºC)2 Bytes9.1 temperature (°C)CWTU
154[Disp][D2] Number - Counter (4-Byte unsigned)Object numeric value is shown4 Bytes12.1 counter pulses (unsigned)CWTU
154[Disp][D2] Number - Counter (4-Byte signed)Object numeric value is shown4 Bytes13.1 counter pulses (signed)CWTU
155[Disp][D2] Text from objectReceived text is shown14 BytesCWTU
156[I1] Current TemperatureTemperature Sensor Value2 Bytes9.1 temperature (°C)CRT
157[I1] Overcooling0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCRT
158[I1] Overheating0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCRT
159[I1] Probe Error0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCRT
160[I2] Current TemperatureTemperature Sensor Value2 Bytes9.1 temperature (°C)CRT
161[I2] Overcooling0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCRT
162[I2] Overheating0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCRT
163[I2] Probe Error0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCRT
164[Internal Temp. Probe] Current TemperatureTemperature Sensor Value2 Bytes9.1 temperature (°C)CRT
165[Internal Temp. Probe] Overcooling0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCRT
166[Internal Temp. Probe] Overheating0 = No Alarm; 1 = Alarm1 Bit1.5 alarmCRT
167[I1] Input Lock0 = Unlock; 1 = Lock1 Bit1.3 enableCW
168[I1] [Short Press] 0Sending of 01 Bit1.1 switchCT
168[I1] [Short Press] 1Sending of 11 Bit1.1 switchCT
168[I1] [Short Press] 0/1 SwitchingSwitching 0/11 Bit1.1 switchCWT
168[I1] [Short Press] Move Up ShutterSending of 0 (Up)1 Bit1.8 up/downCT
168[I1] [Short Press] Move Down ShutterSending of 1 (Down)1 Bit1.8 up/downCT
168[I1] [Short Press] Move Up/Down ShutterSwitching 0/1 (Up/Down)1 Bit1.8 up/downCT
168[I1] [Short Press] Stop/Step Up ShutterSending of 0 (Stop/Step Up)1 Bit1.7 stepCT
168[I1] [Short Press] Stop/Step Down ShutterSending of 1 (Stop/Step Down)1 Bit1.7 stepCT
168[I1] [Short Press] Stop/Step Shutter (Switched)Switching of 0/1 (Stop/Step Up/Down)1 Bit1.7 stepCT
168[I1] [Short Press] BrighterIncrease Brightness4 Bit3.7 dimming controlCT
168[I1] [Short Press] DarkerDecrease Brightness4 Bit3.7 dimming controlCT
168[I1] [Short Press] Brighter/DarkerSwitch Bright/Dark4 Bit3.7 dimming controlCT
168[I1] [Short Press] Light OnSending of 1 (On)1 Bit1.1 switchCT
168[I1] [Short Press] Light OffSending of 0 (Off)1 Bit1.1 switchCT
168[I1] [Short Press] Light On/OffSwitching 0/11 Bit1.1 switchCWT
168[I1] [Short Press] Run SceneSending of 0 - 631 Byte18.1 scene controlCT
168[I1] [Short Press] Save SceneSending of 128 - 1911 Byte18.1 scene controlCT
168[I1] [Switch/Sensor] EdgeSending of 0 or 11 Bit1.1 switchCRWT
168[I1] [Short Press] Constant Value (Integer)0 - 2551 Byte5.10 counter pulses (0..255)CT
168[I1] [Short Press] Constant Value (Percentage)0% - 100%1 Byte5.1 percentage (0..100%)CT
168[I1] [Short Press] Constant Value (Integer)0 - 655352 Bytes7.1 pulsesCT
168[I1] [Short Press] Constant Value (Float)Float Value2 BytesDPT.9CT
168[I1] [Pulse Counter] CounterNumber of Pulses2 Bytes7.1 pulsesCRT
169[I1] [Short Press] Shutter Status (Input)0% = Top; 100% = Bottom1 Byte5.1 percentage (0..100%)CW
169[I1] [Short Press] Dimming Status (Input)0% - 100%1 Byte5.1 percentage (0..100%)CW
169[I1] [Pulse Counter] CounterNumber of Pulses1 Byte5.10 counter pulses (0..255)CRT
170[I1] [Long Press] 0Sending of 01 Bit1.1 switchCT
170[I1] [Long Press] 1Sending of 11 Bit1.1 switchCT
170[I1] [Long Press] 0/1 SwitchingSwitching 0/11 Bit1.1 switchCWT
170[I1] [Long Press] Move Up ShutterSending of 0 (Up)1 Bit1.8 up/downCT
170[I1] [Long Press] Move Down ShutterSending of 1 (Down)1 Bit1.8 up/downCT
170[I1] [Long Press] Move Up/Down ShutterSwitching 0/1 (Up/Down)1 Bit1.8 up/downCT
170[I1] [Long Press] Stop/Step Up ShutterSending of 0 (Stop/Step Up)1 Bit1.7 stepCT
170[I1] [Long Press] Stop/Step Down ShutterSending of 1 (Stop/Step Down)1 Bit1.7 stepCT
170[I1] [Long Press] Stop/Step Shutter (Switched)Switching of 0/1 (Stop/Step Up/Down)1 Bit1.7 stepCT
170[I1] [Long Press] BrighterLong Pr. -> Brighter; Release -> Stop4 Bit3.7 dimming controlCT
170[I1] [Long Press] DarkerLong Pr. -> Darker; Release -> Stop4 Bit3.7 dimming controlCT
170[I1] [Long Press] Brighter/DarkerLong Pr. -> Brighter/Darker; Release -> Stop4 Bit3.7 dimming controlCT
170[I1] [Long Press] Light OnSending of 1 (On)1 Bit1.1 switchCT
170[I1] [Long Press] Light OffSending of 0 (Off)1 Bit1.1 switchCT
170[I1] [Long Press] Light On/OffSwitching 0/11 Bit1.1 switchCWT
170[I1] [Long Press] Run SceneSending of 0 - 631 Byte18.1 scene controlCT
170[I1] [Long Press] Save SceneSending of 128 - 1911 Byte18.1 scene controlCT
170[I1] [Switch/Sensor] Alarm: Breakdown or Sabotage1 = Alarm; 0 = No Alarm1 Bit1.5 alarmCRT
170[I1] [Long Press] Constant Value (Float)Float Value2 BytesDPT.9CT
170[I1] [Long Press] Constant Value (Integer)0 - 655352 Bytes7.1 pulsesCT
170[I1] [Long Press] Constant Value (Percentage)0% - 100%1 Byte5.1 percentage (0..100%)CT
170[I1] [Long Press] Constant Value (Integer)0 - 2551 Byte5.10 counter pulses (0..255)CT
170[I1] [Double Press] 0Sending of 01 Bit1.1 switchCT
170[I1] [Double Press] 1Sending of 11 Bit1.1 switchCT
170[I1] [Double Press] 0/1 SwitchingSwitching 0/11 Bit1.1 switchCWT
170[I1] [Double Press] Save SceneSending of 128 - 1911 Byte18.1 scene controlCT
170[I1] [Double Press] Run SceneSending of 0 - 631 Byte18.1 scene controlCT
171[I1] [Long Press/Release] Stop ShutterRelease -> Stop Shutter1 Bit1.17 triggerCT
171[I1] [Pulse Counter] Reset0 = No Action; 1 = Reset1 Bit1.15 resetCW
172[I1] [Long Press] Dimming Status (Input)0% - 100%1 Byte5.1 percentage (0..100%)CW
172[I1] [Long Press] Shutter Status (Input)0% = Top; 100% = Bottom1 Byte5.1 percentage (0..100%)CW
173[I2] Input Lock0 = Unlock; 1 = Lock1 Bit1.3 enableCW
174[I2] [Short Press] 0Sending of 01 Bit1.1 switchCT
174[I2] [Short Press] 1Sending of 11 Bit1.1 switchCT
174[I2] [Short Press] 0/1 SwitchingSwitching 0/11 Bit1.1 switchCWT
174[I2] [Short Press] Move Up ShutterSending of 0 (Up)1 Bit1.8 up/downCT
174[I2] [Short Press] Move Down ShutterSending of 1 (Down)1 Bit1.8 up/downCT
174[I2] [Short Press] Move Up/Down ShutterSwitching 0/1 (Up/Down)1 Bit1.8 up/downCT
174[I2] [Short Press] Stop/Step Up ShutterSending of 0 (Stop/Step Up)1 Bit1.7 stepCT
174[I2] [Short Press] Stop/Step Down ShutterSending of 1 (Stop/Step Down)1 Bit1.7 stepCT
174[I2] [Short Press] Stop/Step Shutter (Switched)Switching of 0/1 (Stop/Step Up/Down)1 Bit1.7 stepCT
174[I2] [Short Press] BrighterIncrease Brightness4 Bit3.7 dimming controlCT
174[I2] [Short Press] DarkerDecrease Brightness4 Bit3.7 dimming controlCT
174[I2] [Short Press] Brighter/DarkerSwitch Bright/Dark4 Bit3.7 dimming controlCT
174[I2] [Short Press] Light OnSending of 1 (On)1 Bit1.1 switchCT
174[I2] [Short Press] Light OffSending of 0 (Off)1 Bit1.1 switchCT
174[I2] [Short Press] Light On/OffSwitching 0/11 Bit1.1 switchCWT
174[I2] [Short Press] Run SceneSending of 0 - 631 Byte18.1 scene controlCT
174[I2] [Short Press] Save SceneSending of 128 - 1911 Byte18.1 scene controlCT
174[I2] [Switch/Sensor] EdgeSending of 0 or 11 Bit1.1 switchCRWT
174[I2] [Short Press] Constant Value (Integer)0 - 2551 Byte5.10 counter pulses (0..255)CT
174[I2] [Short Press] Constant Value (Percentage)0% - 100%1 Byte5.1 percentage (0..100%)CT
174[I2] [Short Press] Constant Value (Integer)0 - 655352 Bytes7.1 pulsesCT
174[I2] [Short Press] Constant Value (Float)Float Value2 BytesDPT.9CT
174[I2] [Pulse Counter] CounterNumber of Pulses2 Bytes7.1 pulsesCRT
175[I2] [Short Press] Shutter Status (Input)0% = Top; 100% = Bottom1 Byte5.1 percentage (0..100%)CW
175[I2] [Short Press] Dimming Status (Input)0% - 100%1 Byte5.1 percentage (0..100%)CW
175[I2] [Pulse Counter] CounterNumber of Pulses1 Byte5.10 counter pulses (0..255)CRT
176[I2] [Long Press] 0Sending of 01 Bit1.1 switchCT
176[I2] [Long Press] 1Sending of 11 Bit1.1 switchCT
176[I2] [Long Press] 0/1 SwitchingSwitching 0/11 Bit1.1 switchCWT
176[I2] [Long Press] Move Up ShutterSending of 0 (Up)1 Bit1.8 up/downCT
176[I2] [Long Press] Move Down ShutterSending of 1 (Down)1 Bit1.8 up/downCT
176[I2] [Long Press] Move Up/Down ShutterSwitching 0/1 (Up/Down)1 Bit1.8 up/downCT
176[I2] [Long Press] Stop/Step Up ShutterSending of 0 (Stop/Step Up)1 Bit1.7 stepCT
176[I2] [Long Press] Stop/Step Down ShutterSending of 1 (Stop/Step Down)1 Bit1.7 stepCT
176[I2] [Long Press] Stop/Step Shutter (Switched)Switching of 0/1 (Stop/Step Up/Down)1 Bit1.7 stepCT
176[I2] [Long Press] BrighterLong Pr. -> Brighter; Release -> Stop4 Bit3.7 dimming controlCT
176[I2] [Long Press] DarkerLong Pr. -> Darker; Release -> Stop4 Bit3.7 dimming controlCT
176[I2] [Long Press] Brighter/DarkerLong Pr. -> Brighter/Darker; Release -> Stop4 Bit3.7 dimming controlCT
176[I2] [Long Press] Light OnSending of 1 (On)1 Bit1.1 switchCT
176[I2] [Long Press] Light OffSending of 0 (Off)1 Bit1.1 switchCT
176[I2] [Long Press] Light On/OffSwitching 0/11 Bit1.1 switchCWT
176[I2] [Long Press] Run SceneSending of 0 - 631 Byte18.1 scene controlCT
176[I2] [Long Press] Save SceneSending of 128 - 1911 Byte18.1 scene controlCT
176[I2] [Switch/Sensor] Alarm: Breakdown or Sabotage1 = Alarm; 0 = No Alarm1 Bit1.5 alarmCRT
176[I2] [Long Press] Constant Value (Float)Float Value2 BytesDPT.9CT
176[I2] [Long Press] Constant Value (Integer)0 - 655352 Bytes7.1 pulsesCT
176[I2] [Long Press] Constant Value (Percentage)0% - 100%1 Byte5.1 percentage (0..100%)CT
176[I2] [Long Press] Constant Value (Integer)0 - 2551 Byte5.10 counter pulses (0..255)CT
176[I2] [Double Press] 0Sending of 01 Bit1.1 switchCT
176[I2] [Double Press] 1Sending of 11 Bit1.1 switchCT
176[I2] [Double Press] 0/1 SwitchingSwitching 0/11 Bit1.1 switchCWT
176[I2] [Double Press] Save SceneSending of 128 - 1911 Byte18.1 scene controlCT
176[I2] [Double Press] Run SceneSending of 0 - 631 Byte18.1 scene controlCT
177[I2] [Long Press/Release] Stop ShutterRelease -> Stop Shutter1 Bit1.17 triggerCT
177[I2] [Pulse Counter] Reset0 = No Action; 1 = Reset1 Bit1.15 resetCW
178[I2] [Long Press] Dimming Status (Input)0% - 100%1 Byte5.1 percentage (0..100%)CW
178[I2] [Long Press] Shutter Status (Input)0% = Top; 100% = Bottom1 Byte5.1 percentage (0..100%)CW
179[Motion Detector] Scene InputScene Value1 Byte17.1 scene numberCW
180[Motion Detector] Scene OutputScene Value1 Byte18.1 scene controlCT
181[I1] Luminosity0-100%1 Byte5.1 percentage (0..100%)CRT
182[I1] Open Circuit Error0 = No Error; 1 = Open Circuit Error1 Bit1.5 alarmCRT
183[I1] Short Circuit Error0 = No Error; 1 = Short Circuit Error1 Bit1.5 alarmCRT
184[I1] Presence State (Scaling)0-100%1 Byte5.1 percentage (0..100%)CRT
185[I1] Presence State (HVAC)Auto, Comfort, Standby, Economy, Building Protection1 Byte20.102 HVAC modeCRT
186[I1] Presence State (Binary)Binary Value1 Bit1.1 switchCRT
186[I1] Presence: Slave Output1 = Motion Detected1 Bit1.10 start/stopCRT

First 1000 of 1137 group objects shown. Download the .knxprod for the full list.

Parameters (550)
ParameterTypeDefault
Zone AlistDisabled
a1-c1listSolid line
a2-b1listSolid line
b1-b2listSolid line
a2-c2listSolid line
b1-d1listSolid line
b2-d2listSolid line
c1-c2listSolid line
c2-d1listSolid line
d1-d2listSolid line
Main Languagetext
ButtonsunsignedInt 0…11
DisplayunsignedInt 0…11
Box A1unsignedInt 0…11
Border lineslistInvisible line in every border
Indicator representationlistAll indicators are type "permanent"
Middle lines (horizontal)picture
Upper lines (vertical)picture
Lower lines (vertical)picture
Texttext
IndicatorlistIcon
Object to show/hide indicatorunsignedInt 0…11
Typelist1-Bit
# EnumsunsignedInt 1…61
Value 1unsignedInt 0…2550
IconlistOff
Value 2unsignedInt 0…2550
RepresentationlistPermanent
Value 3unsignedInt 0…2550
Value 4unsignedInt 0…2550
Value 5unsignedInt 0…2550
Value 6unsignedInt 0…2550
TypelistScaling
Units (3 Characters)text
Suffix font sizelistSmall
Font sizelistSmall (12 Characters)
Mode TypelistHeat/Cool
HeatunsignedInt 0…11
CoolunsignedInt 0…11
FanunsignedInt 0…11
AutounsignedInt 0…11
DryunsignedInt 0…11
Off/Auto [0%]unsignedInt 0…10
Number of levelslist3: Min. (0% - 33%); Med. (34% - 66%); Max. (67% - 100%)
How to show Off/Auto status?listShow "Auto"
Number of levels (other than Off/Auto)list3: Min. (1% - 33%); Med. (34% - 66%); Max. (67% - 100%)
Button 1listDisabled
FunctionlistSwitch
Dimming Steplist100%
TypelistStandard
Action of the pair buttons (All pairs)listLeft = Off/Down/Decrement; Right = On/Up/Increment
LED Illumination Control (All Buttons)listState-Dependent (Where Available)
LED illumination controllistRegular
LED illumination controllistState-Dependent
State ObjectlistShort Press Object
Valuelist0 = Off; 1 = On
Link the control with a box in the displaylistBox A
pair AunsignedInt 0…10
LED illumination control object valuelist0 = Off; 1 = On
PeriodunsignedInt 1…655351
Heartbeat (Periodic Alive Notification)unsignedInt 0…10
ScreensaverunsignedInt 0…10
Time/DateunsignedInt 0…11
TemperatureunsignedInt 0…11
Select LanguagelistEnglish
Touch LockingunsignedInt 0…10
1-Bit ObjectunsignedInt 0…11
Valuelist0 = Unlock; 1 = Lock
Scene ObjectunsignedInt 0…10
Lock: Scene Number (0 = Disabled)unsignedInt 0…641
Unlock: Scene Number (0 = Disabled)unsignedInt 0…641
Cleaning FunctionunsignedInt 0…10
Time to Exit Cleaning StatusunsignedInt 1…655351
Cleaning Status NotificationlistDisplay Message
Message (16 Characters)textCleaning...
Notify ExpirationlistNo
Length of the WarningunsignedInt 1…655355
Welcome GreetingunsignedInt 0…10
Line 1listFixed
Text (16 Characters)textWelcome Mr/Mrs.
Welcome Back ObjectunsignedInt 0…10
Welcome Back Object (1-Bit)unsignedInt 0…10
ValuelistSend 1
Welcome Back Object (Scene)unsignedInt 0…10
Scene Number (0 = Disabled)unsignedInt 0…641
Time to Activate the Welcome ObjectunsignedInt 1…655351
Additional ConditionlistNo Additional Condition
Number of Condition Objectslist1
Object to Change the Temperature ScaleunsignedInt 0…10
Scale After ProgramminglistCelsius (ºC)
Select LanguagelistSpanish
Select LanguagelistGerman
Select LanguagelistFrench
Select LanguagelistItalian
Line 2listReceived from text Object
Text (16 Characters)text
Line 3listFixed
Text (16 Characters)textTouch the screen
Line 4listFixed
Advanced ConfigurationunsignedInt 0…10
Disable Button SoundunsignedInt 0…10
Valuelist0 = Disable; 1 = Enable
Button Sound After ETS DownloadlistEnabled
Valuelist0 = No Action; 1 = Doorbell
SoundslistDefault
Object for DoorbellunsignedInt 0…10
Enable/Disable Button Sound Through a 1-Bit ObjectunsignedInt 0…11
Update ObjectslistDisabled
DelayunsignedInt 1…6553510
ValuelistDisabled
Input 1listDisabled
Input 2listDisabled
ThermostatunsignedInt 0…10
InputsunsignedInt 0…10
Touch Lock NotificationlistDisplay Message
Message (16 Characters)textTouch Locked
Time to Exit Cleaning StatusunsignedInt 5…6553515
DelayunsignedInt 1…655351
bTestAndPrivateObjects(virtual)unsignedInt 0…10
Language 2unsignedInt 0…10
Language 3unsignedInt 0…10
Language 4unsignedInt 0…10
Main LanguageunsignedInt 0…11
Language 5unsignedInt 0…10
Scene NumberunsignedInt 1…641
Time and Date Request DelayunsignedInt 0…10
Sound TypelistSound 1
Time to Consider InactivityunsignedInt 1…655351
Run Button Action on Screensaver Exit or Alarm MuteunsignedInt 0…10
LEDs Flashing During Welcome StatusunsignedInt 0…10
Valuelist0 = No Alarm; 1 = Alarm
Object for AlarmunsignedInt 0…10
ActionlistSend 0
Object Valuefloat -671088.64…670433.280
Action on HoldlistSend 1
Action on ReleaselistSend 0
Action on Short PresslistSend 0
ValueunsignedInt 0…2550
Action on Long PresslistSend 1
Long Press Threshold TimeunsignedInt 4…506
Object ValueunsignedInt 0…1000
ActionlistRun
Sizelist1-Byte
SignlistSigned
Object ValueunsignedInt 0…655350
ActionlistLeft = Decrease; Right = Increase
Minimum ValueunsignedInt 0…655350
Maximum ValueunsignedInt 0…6553565535
Increment on Short PressunsignedInt 1…655351
Increment on Long PressunsignedInt 1…6553510
Object ValueunsignedInt 0…2550
Object ValuesignedInt -32768…327670
Object ValuesignedInt -128…1270
Minimum ValueunsignedInt 0…2550
Minimum ValuesignedInt -32768…32767-32768
Minimum ValuesignedInt -128…127-128
Maximum ValueunsignedInt 0…255255
Maximum ValuesignedInt -32768…3276732767
Maximum ValuesignedInt -128…127127
Increment on Short PressunsignedInt 1…2551
Increment on Long PressunsignedInt 1…25510
ActionlistLeft = 0; Right = 1
ActionlistLeft = Off/Decrease; Right = On/Increase
Speed Levelslist1
Control Typelist1 bit (Decrease/Increase)
CyclicalunsignedInt 0…10
Auto ModeunsignedInt 0…10
Dedicated Object for Auto ModeunsignedInt 0…10
Value to Set Auto ModelistSend 0 to Set Auto Mode
Long Press to Activate Auto ModeunsignedInt 0…10
Allow Speed 0unsignedInt 0…10
Minimum Valuefloat -671088.64…670433.28-671088.64
Maximum Valuefloat -671088.64…670433.28670433.28
Increment on Short Pressfloat 0.1…670433.280.5
Increment on Long Pressfloat 0.1…670433.281
Minimum Valuefloat -99…19910
Maximum Valuefloat -99…19930
Increment on Short Pressfloat 0.1…100.5
Increment on Long Pressfloat 0.1…101
Minimum ValueunsignedInt 0…1000
Maximum ValueunsignedInt 1…100100
Increment on Short PressunsignedInt 1…1001
Increment on Long PressunsignedInt 1…10010
ActionlistLeft = Downwards; Right = Upwards
ActionlistLeft = Stop/Backward; Right = Start/Forward
Action on Short PresslistLeft = 0; Right = 1
Action on Long PresslistLeft = 0; Right = 1
Increment on Short PresssignedInt 1…327671
Increment on Short PresssignedInt 1…1271
Increment on Long PresssignedInt 1…3276710
Increment on Long PresssignedInt 1…12710
ComfortunsignedInt 0…11
EconomyunsignedInt 0…11
StandbyunsignedInt 0…11
Building ProtectionunsignedInt 0…11
Allow Speed 0 (auto)unsignedInt 0…10
Object to UselistGeneral Scene Object
SteplistToggle 0/1
RepresentationlistText
Infotext
Language 2text
Language 3text
Language 4text
Language 5text
Run Welcome Greeting with Text Object UpdateunsignedInt 0…10
Link the Control with a Box in the DisplaylistBox A
Text for "Heat"text
Text for "Cool"text
Text for "Auto"text
Text for "Fan"text
Texto for "Dry"text
Text for "Comfort"text
Text for "Standby"text
Text for "Economy"text
Text for "Building Protection"text
Font sizelistSmall
Font sizelistSmall (6 Characters)
Send Object TriggerlistPress Button
checkHWlist
Box A2unsignedInt 0…11
IndicatorunsignedInt 0…10
Zone BlistDisabled
Box B1unsignedInt 0…11
Box B2unsignedInt 0…11
Zone ClistDisabled
Box C1unsignedInt 0…11
Box C2unsignedInt 0…11
Zone DlistDisabled
Box D1unsignedInt 0…11
Box D2unsignedInt 0…11
Time to Consider InactivityunsignedInt 30…6553530
Button 2listDisabled
Button 3listDisabled
Button 4listDisabled
Button 5listDisabled
pair BunsignedInt 0…10
StatelistMake-Up Request
Page StylelistNormal Page
Zone BlistSetpoint
Horizontal linespicture
Vertical linespicture
c1-blistSolid line
a1-blistSolid line
a2-blistSolid line
Layoutpicture
Enable Real TemperatureunsignedInt 0…10
Main Temperature to ShowlistSetpoint
Trigger Valuelist0 = No Alarm; 1 = Alarm
Enable Object Configurationlist0 = Disable; 1 = Enable
Alarm icon (Zone B)listOff
Value to Activate Auto ModelistReceive 0 to Set Auto Mode
Fan Levelslist3
bDummyParams(virtual)unsignedInt 0…10
c2-blistSolid line
a-blistSolid line
c-blistSolid line
a1-a2listSolid line
Link the control with a box in the displaylistBox A1
Link the Control with a Box in the DisplaylistBox A1
Link the control with a box in the displaylistBox B1
Indicatorlist[Climate] Temperature
IndicatorlistThermostat Fan
IndicatorlistThermostat Window Alarm
Font sizelistHuge
Zone DlistSetpoint
HumidityunsignedInt 0…10
bHumHide(Virtual)unsignedInt 0…10
AlarmunsignedInt 0…10
Button I1unsignedInt 0…10
Button I2unsignedInt 0…10
Button I4unsignedInt 0…10
Button I5unsignedInt 0…10
Pair AunsignedInt 0…10
Pair BunsignedInt 0…10
Box A1unsignedInt 0…10
Box A2unsignedInt 0…10
Box BunsignedInt 0…11
Box C1unsignedInt 0…10
Box C2unsignedInt 0…10
Box D1unsignedInt 0…10
Box CunsignedInt 0…10
Button I3unsignedInt 0…10
Include Plus Sign before Positive NumbersunsignedInt 0…10
Display: Backlight Level - ActiveunsignedInt 1…100100
Display: Backlight AttenuationlistTurn Off the Screen After a Long Time of Inactivity
Night ModeunsignedInt 0…10
Display: Backlight Level - ActiveunsignedInt 0…10050
Control Object: 1-BitunsignedInt 0…11
Valuelist0 = Normal Mode; 1 = Night Mode
Control Object: SceneunsignedInt 0…10
Normal Mode: Scene Number (0 = Disabled)unsignedInt 0…641
Night Mode: Scene Number (0 = Disabled)unsignedInt 0…641
Backlight Mode after ETS DownloadlistNormal Mode
Normal ModeunsignedInt 0…11
LEDs: ON, Brightness LevelunsignedInt 0…100100
LEDs: OFF, Brightness LevelunsignedInt 0…1000
LEDs: Inactivity, Brightness LevelunsignedInt 0…1000
Display: Contrast Level after ETS DownloadunsignedInt 1…10070
LEDs: ON, Brightness LevelunsignedInt 0…10050
LEDs: OFF, Brightness LevelunsignedInt 0…1001
Display: Time to Turn OffunsignedInt 1…655353
Display: Backlight Level - AttenuatedunsignedInt 0…10060
Display: Backlight Level - AttenuatedunsignedInt 0…10020
Display: Time to Turn OffunsignedInt 30…6553530
Temperature Sending Period (0 = Disabled)unsignedInt 0…65535600
Temperature Sensor CalibrationsignedInt -50…500
Send with a Temperature Change (0 = Disabled)unsignedInt 0…2550
Temperature ProtectionlistNo
Overheating Temp.signedInt -30…12540
Overcooling Temp.signedInt -30…12510
HysteresisunsignedInt 1…20020
Probe TypelistZennio Probe
Temperature T1signedInt -55…1500
Temperature T2signedInt -55…15025
Temperature T3signedInt -55…150100
Resistance R1 (at T1)float 0…26843545622137
Resistance R2 (at T2)float 0…2684354566800
Resistance R3 (at T3)float 0…268435456460
Resistance Obtained at 0 °Cfloat 0…26843545622137
Resistance Obtained at 10 °Cfloat 0…26843545613515.65
Resistance Obtained at 20 °Cfloat 0…2684354568492.59
Resistance Obtained at 30 °Cfloat 0…2684354565479.41
Resistance Obtained at 40 °Cfloat 0…2684354563622.6
Resistance Obtained at 50 °Cfloat 0…2684354562449.57
Resistance Obtained at 60 °Cfloat 0…2684354561691.26
Resistance Obtained at 70 °Cfloat 0…2684354561190.46
Resistance Obtained at 80 °Cfloat 0…268435456853.1
Resistance Obtained at 90 °Cfloat 0…268435456621.61
Ambient Luminosity SensorunsignedInt 0…10
Proximity SensorunsignedInt 0…11
ThresholdunsignedInt 0…10050
HysteresisunsignedInt 0…5010
Binary ObjectunsignedInt 0…10
Valuelist0 = Over Threshold; 1 = Under Threshold
Over Threshold: Scene Number (0 = Disabled)unsignedInt 0…641
Under Threshold: Scene Number (0 = Disabled)unsignedInt 0…641
Threshold TypelistPercentage
ThresholdunsignedInt 0…65535150
Humidity Sensor CalibrationsignedInt -12…120
Humidity Sending Period (0 = Disabled)unsignedInt 0…65535600
Send with a Humidity Change (0 = Disabled)unsignedInt 0…255
Humidity ProtectionlistNo
High HumidityunsignedInt 0…10065
Low HumidityunsignedInt 0…10025
HysteresisunsignedInt 1…255
Dew Point Sending Period (0 = Disabled)unsignedInt 0…65535600
Send with a Dew Point Change (0 = Disabled)unsignedInt 0…25510
Condensation ProtectionunsignedInt 0…10
Dew Point OffsetunsignedInt 0…25515
Threshold ObjectsunsignedInt 0…10
Debounce TimeunsignedInt 10…25520
TypelistPush Button
Long Press TimeunsignedInt 1…505
Double Press TimeunsignedInt 1…505
Double PressunsignedInt 0…2550
ActionlistNo Action
ActionlistSending of 0/1
ResponselistSwitching 0/1
Periodic Response SendinglistNo
ResponselistUp
ResponselistLight On
ResponselistRun Scene
SceneunsignedInt 1…641
ResponseunsignedInt 0…2550
ResponseunsignedInt 0…1000
ResponseunsignedInt 0…655350
Responsefloat -671088.64…670433.280
Sending PeriodunsignedInt 1…2551
Sending PeriodunsignedInt 1…181
DelayunsignedInt 0…2550
DelayunsignedInt 0…180
ResponselistDarker
SecurityunsignedInt 0…2550
Switch/Sensor TypelistN.O. (Parallel Resistor)
Resistor Valuelist2.2 kohm
Rising Edgelist1
Falling Edgelist0
Periodic Sending of "0" (0 = Disabled)unsignedInt 0…2550
Periodic Sending of "0" (0 = Disabled)unsignedInt 0…180
Periodic Sending of "1" (0 = Disabled)unsignedInt 0…2550
Periodic Sending of "1" (0 = Disabled)unsignedInt 0…180
Sending of "0" DelayunsignedInt 0…2550
Sending of "0" DelayunsignedInt 0…180
Sending of "1" DelayunsignedInt 0…2550
Sending of "1" DelayunsignedInt 0…180
Resend Last Edge Action on Bus Voltage RecoveryunsignedInt 0…2550
Sending DelayunsignedInt 2…2552
Evaluate the Input State after Unlock or ResetunsignedInt 0…2551
Edge TypelistRising Edge
Counter Sizelist1-Byte
Sending TypelistPeriodic
Periodic SendingunsignedInt 1…2551
Periodic SendingunsignedInt 1…181
Final ValueunsignedInt 1…255255
Final ValueunsignedInt 1…6553565535
VersionlistStandard Type
Short PressunsignedInt 0…2550
Long PressunsignedInt 0…2550
Reference TemperaturelistTemperature Source 1
Setpoint Working Mode (See User Manual)listAbsolute Setpoints
1-bit Objects Working Mode (See User Manual)listDisabled
Default ModelistEconomy
Comfort Prolongation TimeunsignedInt 10…25530
Keep Offset after a Special Mode ChangelistYes
Maximum Offsetfloat 0…205
Minimum Offsetfloat -20…0-5
Comfort Offset (Heating)float -10…00
Standby Offset (Heating)float -10…0-3
Economy Offset (Heating)float -10…0-5
Overheating Protection Setpointfloat 25…12035
Freezing Protection Setpointfloat -10…157
Thermostat FunctionlistHeating
H/C Automatic ChangeoverlistDisabled
H/C Mode After ProgramminglistHeating
Additional Cooling Activation BandsignedInt 5…10025
Additional Heating Activation BandsignedInt -100…-5-25
Control Methodlist2-Point Control
Upper HysteresisunsignedInt 1…20010
Lower HysteresisunsignedInt 1…20010
Control TypelistContinuous (1 byte)
Control ParameterslistCooling Ceiling (5K/240min)
Control ParameterslistWarm Water (5K/150min)
Proportional BandunsignedInt 1…154
Integral TimeunsignedInt 5…255150
Restart Accumulated Error on Saturation?listYes
PI CycleunsignedInt 1…25515
Thermostat Always On?listYes
Startup Setting (on Bus Voltage Recovery)listLast (Before Bus Failure)
Initial Setpoint (After Programming)float -20…10022
Sending Statuses on Bus Voltage RecoverylistNo
Sending DelayunsignedInt 0…2550
Comfort Setpoint (Heating)float -20…10021
Comfort Setpoint (Cooling)float -20…10023
Standby Offset (Cooling)float 0…103
Economy Offset (Cooling)float 0…105
Keep SetpointslistYes
Basic Setpoint (After Programming)float -20…10022
Automatic On when a Special Mode ArriveslistDisabled
Comfort ProlongationlistDisabled
Window StatuslistDisabled
Initial Mode (After Programming)listEconomy
Resending Period (0 = Disabled)unsignedInt 0…2550
System 2 - Control VariableslistIndependent Objects for Heating and Cooling
System 1 - Control VariableslistIndependent Objects for Heating and Cooling
Send Both H/C Control Signals Periodically?listNo
Comfort Prolongation TimeunsignedInt 1…2551
PI CycleunsignedInt 10…25560
Resending Period (0 = Disabled)unsignedInt 0…180
PWM Minimum TimeunsignedInt 1…25510
If the Switching Time Is Lower than the MinimumlistSwitch the Control Signal Using the Minimum Time
Comfort Offset (Cooling)float 0…100
After a Special Mode Change?listYes
After a H/C Mode Change?listNo
After a Setpoint Change?listNo
Lower Dead BandunsignedInt 0…10010
Upper Dead BandunsignedInt 0…10010
Thermostat TypelistAdvanced
ScenesunsignedInt 0…10
Scene 1unsignedInt 0…10
On/OfflistDo Not Change
H/C ModelistDo Not Change
Setpoint Valuefloat -20…10022
SetpointlistDo Not Change
Scene 2unsignedInt 0…10
Scene 3unsignedInt 0…10
Scene 4unsignedInt 0…10
Scene 5unsignedInt 0…10
Additional Cooling Deactivation HysteresissignedInt 1…205
Cooling Systems NumberlistOne System
Main Systemlist[System 1] Cooling Control
Additional Heating Deactivation HysteresissignedInt -20…-1-5
Heating Systems NumberlistOne System
Main Systemlist[System 1] Heating Control
Setpoint StepunsignedInt 1…1005
Restart Accumulated Error after Setpoint Change?listYes
Set to 1 if cooling setpoint is lesser than heating oneunsignedInt 0…10
PWM Minimum TimeunsignedInt 1…301
th[0].altBandBiggerThanHystlistNo
th[0].isHeatAltBandGTHyst2PlistNo
Device Recovery Objects (Send 0 and 1)unsignedInt 0…10
Scenes after DownloadlistKeep Saved Scenes
Luminosity SendingunsignedInt 0…2550
Period (0 = Disabled)unsignedInt 0…25515
Luminosity Change to Send (0 = Disabled)unsignedInt 0…1000
Channel 1unsignedInt 0…2550
Length of DetectionunsignedInt 1…25510
Length of DetectionunsignedInt 1…2551
Length of DetectionunsignedInt 1…181
Blind TimeunsignedInt 0…180
Blind TimeunsignedInt 0…2550
Reset Luminosity after No DetectionunsignedInt 0…2550
Reset DelayunsignedInt 0…600
Channel EnablementlistAlways Enabled
Configurationlist0 = Disable; 1 = Enable
Scene to DisableunsignedInt 1…642
Scene to EnableunsignedInt 1…641
Send when DisablinglistNothing
Send when EnablinglistNothing
Time to EnableunsignedInt 0…2550
Initial State (after reset)listLast state

First 500 of 550 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Flat Display v2 2.6 2.6 latest$52A1B4E52026-11-25843 KBDownload

About this file

This is the official ETS product database for the Zennio Flat Display v2 (ZVIFDV2), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.