KNX Database
Zennio ZVI-Z41PRO Z41 Pro

Z41 Pro ZVI-Z41PRO

Zennio · Order number ZVI-Z41PRO · Display › LCD Display

Full Color Capacitive Touch Panel with IP Connection

Download .knxprod Z41 Pro 3.6 3.6 · 3.8 MB

Product

ManufacturerZennio
Product nameZ41 Pro
Order numberZVI-Z41PRO
HardwareZ41 Pro
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2019-05-14
Languagesen-US, es-ES, de-DE, fr-FR, it-IT, ru-RU
Catalog entryM-0071_H-ZVI.2DZ41PRO-1_HP-5181-36-7D87_CI-ZVI.2DZ41PRO-1
Fingerprint7D87
SHA-2560499bef2300ac1ef96747f5372197c978e1589a64026f2e2bb24c425bc988f9f
First seen2026-11-25
Markets59 markets

Application program: Z41 Pro 3.6 3.6

Application number$5181
Version3.6
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters23380
Group objects11045
Group objects (11045)
NoNameFunctionSizeDPTFlags
1[General] TimeCurrent Time3 Bytes10.1 time of dayCRWTU
2[General] DateCurrent Date3 Bytes11.1 dateCRWTU
3[General] Scenes: SendScene Value1 Byte18.1 scene controlCT
4[General] Scenes: ReceiveScene Value1 Byte17.1 scene numberCW
5[General] Internal TemperatureCurrent Temperature (Built-in Sensor)2 Bytes9.1 temperature (°C)CRT
6[General] External TemperatureTemperature to Show in the Display2 Bytes9.1 temperature (°C)CWU
7[General] Select Language0 = Main; 1 = Lang. 2; ... ; 4 = Lang. 51 ByteCW
8[General] Select LanguageLanguage selection through ISO 639-1 two letters code2 Bytes234.1 language code (ASCII)CW
9[General] Illumination0=No Action; 1=Light Display1 Bit1.16 acknowledgeCW
10[General] Backlight Mode0=Normal Mode; 1=Night Mode1 Bit1.24 day/nightCW
10[General] Backlight Mode0=Night Mode; 1=Normal Mode1 Bit1.24 day/nightCW
11[General] Touch Lock0=Unlocked; 1=Locked1 Bit1.3 enableCW
11[General] Touch Lock0=Locked; 1=Unlocked1 Bit1.3 enableCW
12[General] Welcome Object1-Bit Generic Control1 Bit1.1 switchCRT
13[General] Welcome Object - Additional ConditionAdditional Condition Object 11 Bit1.1 switchCW
14[General] Welcome Object - Additional ConditionAdditional Condition Object 21 Bit1.1 switchCW
15[General] Welcome Object - Additional ConditionAdditional Condition Object 31 Bit1.1 switchCW
16[General] Welcome Object - Additional ConditionAdditional Condition Object 41 Bit1.1 switchCW
17[General] Welcome Object - Additional ConditionAdditional Condition Object 51 Bit1.1 switchCW
18[General] Welcome Greeting0 = Finish Welcome; 1 = Run Welcome1 Bit1.1 switchCWTU
19[General] Welcome Greeting - Line 1Text to show on the display at Line 114 BytesCW
20[General] Welcome Greeting - Line 2Text to show on the display at Line 214 BytesCW
21[General] Welcome Greeting - Line 3Text to show on the display at Line 314 BytesCW
22[General] Welcome Greeting - Line 4Text to show on the display at Line 414 BytesCW
23[General] Temperature Scale0 = ºC; 1 = ºF1 Bit1.1 switchCWTU
24[Profile] Brightness0-100%1 Byte5.1 percentage (0..100%)CWT
25[Profile] Contrast0-100%1 Byte5.1 percentage (0..100%)CWT
26[Profile] Melody0=Mute; 1=Melody 1; 2=Melody 2; 3=Melody 31 ByteCWT
27[Profile] Theme0=Ocean; 1=Sky; 2=Night; 3=Twilight; 4=Egg Shell; 5=Seaside; 6=Rioja; 7=Forest1 ByteCWT
28[P1][B1] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
28[P1][B1] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
28[P1][B1] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
28[P1][B1] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
28[P1][B1] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
28[P1][B1] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
28[P1][B1] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
28[P1][B1] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
28[P1][B1] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
28[P1][B1] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
28[P1][B1] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
28[P1][B1] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
28[P1][B1] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
28[P1][B1] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
28[P1][B1] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
28[P1][B1] Alarm TriggerTrigger1 Bit1.5 alarmCWU
28[P1][B1] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
28[P1][B1] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
28[P1][B1] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
28[P1][B1] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
28[P1][B1] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
28[P1][B1] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
28[P1][B1] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
28[P1][B1] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
28[P1][B1] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
28[P1][B1] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
28[P1][B1] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
28[P1][B1] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
28[P1][B1] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
28[P1][B1] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
28[P1][B1] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
28[P1][B1] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
28[P1][B1] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
28[P1][B1] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
28[P1][B1] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
28[P1][B1] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
28[P1][B1] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
29[P1][B1] Binary Control1-Bit Control1 Bit1.1 switchCRT
29[P1][B1] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
29[P1][B1] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
29[P1][B1] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
29[P1][B1] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
29[P1][B1] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
29[P1][B1] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
29[P1][B1] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
29[P1][B1] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
29[P1][B1] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
29[P1][B1] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
29[P1][B1] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
29[P1][B1] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
29[P1][B1] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
29[P1][B1] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
29[P1][B1] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
29[P1][B1] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
29[P1][B1] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
29[P1][B1] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
29[P1][B1] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
29[P1][B1] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
29[P1][B1] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Scaling)100%1 Byte5.1 percentage (0..100%)CRT
29[P1][B1] Fan Control (Enumerated)Auto, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)Auto, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)Auto, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)Auto, 1, 21 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)Auto, 11 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)0, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)0, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)0, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)0, 1, 21 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)0, 11 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)1, 2, 31 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)1, 21 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Fan Control (Enumerated)11 Byte5.10 counter pulses (0..255)CRT
29[P1][B1] Macro: Started0 = Macro Started; 1 = Nothing1 Bit1.1 switchCRT
29[P1][B1] Macro: Started0 = Nothing; 1 = Macro Started1 Bit1.1 switchCRT
30[P1][B1] Shutter - Stop/Step0=Stop/Step Up; 1=Stop/Step Down1 Bit1.7 stepCRT
30[P1][B1] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
30[P1][B1] Blue Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
30[P1][B1] Consumption Monitor: CostLocal Currency2 BytesCWTU
30[P1][B1] Chrono-thermostat: On/Off0 = Off; 1 = On1 Bit1.1 switchCRT
30[P1][B1] White Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
30[P1][B1] Holiday (1 Byte)0...2551 Byte5.10 counter pulses (0..255)CRT
30[P1][B1] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.3 enableCRWTU
30[P1][B1] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.3 enableCRWTU
31[P1][B1] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
31[P1][B1] Shutter Positioning (Only Macros)0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CRT
31[P1][B1] Precise Dimming (Only Macros)1-Byte Dimmer Control1 Byte5.1 percentage (0..100%)CRT
32[P1][B1] Consumption Monitor: Volumem³4 Bytes14.76 volume (m³)CWTU
32[P1][B1] Consumption Monitor: EnergyWh4 Bytes13.10 active energy (Wh)CWTU
32[P1][B1] Consumption Monitor: EnergykWh4 Bytes13.13 active energy (kWh)CWTU
32[P1][B1] 14-Byte Text IndicatorUTF-8 Text String14 BytesCWTU
33[P1][B1] Consumption Monitor: CO₂kg CO₂2 BytesCWTU
34[P1][B1] Consumption Monitor: Request0=No Action; 1=Request1 Bit1.1 switchCRT
35[P1][B1] Consumption Monitor: Reset0=No Action; 1=Reset1 Bit1.15 resetCRT
36[P1][B2] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
36[P1][B2] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
36[P1][B2] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
36[P1][B2] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
36[P1][B2] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
36[P1][B2] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
36[P1][B2] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
36[P1][B2] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
36[P1][B2] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
36[P1][B2] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
36[P1][B2] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
36[P1][B2] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
36[P1][B2] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
36[P1][B2] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
36[P1][B2] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
36[P1][B2] Alarm TriggerTrigger1 Bit1.5 alarmCWU
36[P1][B2] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
36[P1][B2] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
36[P1][B2] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
36[P1][B2] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
36[P1][B2] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
36[P1][B2] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
36[P1][B2] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
36[P1][B2] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
36[P1][B2] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
36[P1][B2] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
36[P1][B2] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
36[P1][B2] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
36[P1][B2] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
36[P1][B2] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
36[P1][B2] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
36[P1][B2] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
36[P1][B2] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
36[P1][B2] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
36[P1][B2] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
36[P1][B2] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
36[P1][B2] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
37[P1][B2] Binary Control1-Bit Control1 Bit1.1 switchCRT
37[P1][B2] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
37[P1][B2] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
37[P1][B2] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
37[P1][B2] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
37[P1][B2] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
37[P1][B2] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
37[P1][B2] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
37[P1][B2] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
37[P1][B2] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
37[P1][B2] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
37[P1][B2] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
37[P1][B2] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
37[P1][B2] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
37[P1][B2] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
37[P1][B2] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
37[P1][B2] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
37[P1][B2] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
37[P1][B2] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
37[P1][B2] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
37[P1][B2] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
37[P1][B2] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Scaling)100%1 Byte5.1 percentage (0..100%)CRT
37[P1][B2] Fan Control (Enumerated)Auto, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)Auto, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)Auto, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)Auto, 1, 21 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)Auto, 11 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)0, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)0, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)0, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)0, 1, 21 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)0, 11 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)1, 2, 31 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)1, 21 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Fan Control (Enumerated)11 Byte5.10 counter pulses (0..255)CRT
37[P1][B2] Macro: Started0 = Macro Started; 1 = Nothing1 Bit1.1 switchCRT
37[P1][B2] Macro: Started0 = Nothing; 1 = Macro Started1 Bit1.1 switchCRT
38[P1][B2] Shutter - Stop/Step0=Stop/Step Up; 1=Stop/Step Down1 Bit1.7 stepCRT
38[P1][B2] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
38[P1][B2] Blue Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
38[P1][B2] Consumption Monitor: CostLocal Currency2 BytesCWTU
38[P1][B2] Chrono-thermostat: On/Off0 = Off; 1 = On1 Bit1.1 switchCRT
38[P1][B2] White Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
38[P1][B2] Holiday (1 Byte)0...2551 Byte5.10 counter pulses (0..255)CRT
38[P1][B2] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.3 enableCRWTU
38[P1][B2] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.3 enableCRWTU
39[P1][B2] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
39[P1][B2] Shutter Positioning (Only Macros)0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CRT
39[P1][B2] Precise Dimming (Only Macros)1-Byte Dimmer Control1 Byte5.1 percentage (0..100%)CRT
40[P1][B2] Consumption Monitor: Volumem³4 Bytes14.76 volume (m³)CWTU
40[P1][B2] Consumption Monitor: EnergyWh4 Bytes13.10 active energy (Wh)CWTU
40[P1][B2] Consumption Monitor: EnergykWh4 Bytes13.13 active energy (kWh)CWTU
40[P1][B2] 14-Byte Text IndicatorUTF-8 Text String14 BytesCWTU
41[P1][B2] Consumption Monitor: CO₂kg CO₂2 BytesCWTU
42[P1][B2] Consumption Monitor: Request0=No Action; 1=Request1 Bit1.1 switchCRT
43[P1][B2] Consumption Monitor: Reset0=No Action; 1=Reset1 Bit1.15 resetCRT
44[P1][B3] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
44[P1][B3] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
44[P1][B3] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
44[P1][B3] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
44[P1][B3] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
44[P1][B3] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
44[P1][B3] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
44[P1][B3] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
44[P1][B3] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
44[P1][B3] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
44[P1][B3] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
44[P1][B3] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
44[P1][B3] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
44[P1][B3] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
44[P1][B3] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
44[P1][B3] Alarm TriggerTrigger1 Bit1.5 alarmCWU
44[P1][B3] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
44[P1][B3] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
44[P1][B3] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
44[P1][B3] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
44[P1][B3] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
44[P1][B3] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
44[P1][B3] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
44[P1][B3] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
44[P1][B3] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
44[P1][B3] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
44[P1][B3] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
44[P1][B3] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
44[P1][B3] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
44[P1][B3] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
44[P1][B3] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
44[P1][B3] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
44[P1][B3] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
44[P1][B3] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
44[P1][B3] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
44[P1][B3] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
44[P1][B3] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
45[P1][B3] Binary Control1-Bit Control1 Bit1.1 switchCRT
45[P1][B3] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
45[P1][B3] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
45[P1][B3] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
45[P1][B3] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
45[P1][B3] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
45[P1][B3] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
45[P1][B3] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
45[P1][B3] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
45[P1][B3] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
45[P1][B3] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
45[P1][B3] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
45[P1][B3] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
45[P1][B3] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
45[P1][B3] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
45[P1][B3] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
45[P1][B3] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
45[P1][B3] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
45[P1][B3] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
45[P1][B3] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
45[P1][B3] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
45[P1][B3] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Scaling)100%1 Byte5.1 percentage (0..100%)CRT
45[P1][B3] Fan Control (Enumerated)Auto, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)Auto, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)Auto, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)Auto, 1, 21 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)Auto, 11 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)0, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)0, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)0, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)0, 1, 21 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)0, 11 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)1, 2, 31 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)1, 21 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Fan Control (Enumerated)11 Byte5.10 counter pulses (0..255)CRT
45[P1][B3] Macro: Started0 = Macro Started; 1 = Nothing1 Bit1.1 switchCRT
45[P1][B3] Macro: Started0 = Nothing; 1 = Macro Started1 Bit1.1 switchCRT
46[P1][B3] Shutter - Stop/Step0=Stop/Step Up; 1=Stop/Step Down1 Bit1.7 stepCRT
46[P1][B3] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
46[P1][B3] Blue Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
46[P1][B3] Consumption Monitor: CostLocal Currency2 BytesCWTU
46[P1][B3] Chrono-thermostat: On/Off0 = Off; 1 = On1 Bit1.1 switchCRT
46[P1][B3] White Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
46[P1][B3] Holiday (1 Byte)0...2551 Byte5.10 counter pulses (0..255)CRT
46[P1][B3] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.3 enableCRWTU
46[P1][B3] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.3 enableCRWTU
47[P1][B3] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
47[P1][B3] Shutter Positioning (Only Macros)0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CRT
47[P1][B3] Precise Dimming (Only Macros)1-Byte Dimmer Control1 Byte5.1 percentage (0..100%)CRT
48[P1][B3] Consumption Monitor: Volumem³4 Bytes14.76 volume (m³)CWTU
48[P1][B3] Consumption Monitor: EnergyWh4 Bytes13.10 active energy (Wh)CWTU
48[P1][B3] Consumption Monitor: EnergykWh4 Bytes13.13 active energy (kWh)CWTU
48[P1][B3] 14-Byte Text IndicatorUTF-8 Text String14 BytesCWTU
49[P1][B3] Consumption Monitor: CO₂kg CO₂2 BytesCWTU
50[P1][B3] Consumption Monitor: Request0=No Action; 1=Request1 Bit1.1 switchCRT
51[P1][B3] Consumption Monitor: Reset0=No Action; 1=Reset1 Bit1.15 resetCRT
52[P1][B4] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
52[P1][B4] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
52[P1][B4] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
52[P1][B4] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
52[P1][B4] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
52[P1][B4] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
52[P1][B4] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
52[P1][B4] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
52[P1][B4] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
52[P1][B4] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
52[P1][B4] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
52[P1][B4] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
52[P1][B4] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
52[P1][B4] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
52[P1][B4] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
52[P1][B4] Alarm TriggerTrigger1 Bit1.5 alarmCWU
52[P1][B4] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
52[P1][B4] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
52[P1][B4] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
52[P1][B4] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
52[P1][B4] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
52[P1][B4] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
52[P1][B4] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
52[P1][B4] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
52[P1][B4] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
52[P1][B4] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
52[P1][B4] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
52[P1][B4] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
52[P1][B4] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
52[P1][B4] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
52[P1][B4] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
52[P1][B4] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
52[P1][B4] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
52[P1][B4] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
52[P1][B4] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
52[P1][B4] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
52[P1][B4] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
53[P1][B4] Binary Control1-Bit Control1 Bit1.1 switchCRT
53[P1][B4] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
53[P1][B4] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
53[P1][B4] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
53[P1][B4] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
53[P1][B4] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
53[P1][B4] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
53[P1][B4] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
53[P1][B4] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
53[P1][B4] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
53[P1][B4] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
53[P1][B4] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
53[P1][B4] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
53[P1][B4] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
53[P1][B4] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
53[P1][B4] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
53[P1][B4] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
53[P1][B4] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
53[P1][B4] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
53[P1][B4] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
53[P1][B4] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
53[P1][B4] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Scaling)100%1 Byte5.1 percentage (0..100%)CRT
53[P1][B4] Fan Control (Enumerated)Auto, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)Auto, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)Auto, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)Auto, 1, 21 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)Auto, 11 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)0, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)0, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)0, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)0, 1, 21 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)0, 11 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)1, 2, 31 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)1, 21 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Fan Control (Enumerated)11 Byte5.10 counter pulses (0..255)CRT
53[P1][B4] Macro: Started0 = Macro Started; 1 = Nothing1 Bit1.1 switchCRT
53[P1][B4] Macro: Started0 = Nothing; 1 = Macro Started1 Bit1.1 switchCRT
54[P1][B4] Shutter - Stop/Step0=Stop/Step Up; 1=Stop/Step Down1 Bit1.7 stepCRT
54[P1][B4] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
54[P1][B4] Blue Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
54[P1][B4] Consumption Monitor: CostLocal Currency2 BytesCWTU
54[P1][B4] Chrono-thermostat: On/Off0 = Off; 1 = On1 Bit1.1 switchCRT
54[P1][B4] White Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
54[P1][B4] Holiday (1 Byte)0...2551 Byte5.10 counter pulses (0..255)CRT
54[P1][B4] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.3 enableCRWTU
54[P1][B4] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.3 enableCRWTU
55[P1][B4] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
55[P1][B4] Shutter Positioning (Only Macros)0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CRT
55[P1][B4] Precise Dimming (Only Macros)1-Byte Dimmer Control1 Byte5.1 percentage (0..100%)CRT
56[P1][B4] Consumption Monitor: Volumem³4 Bytes14.76 volume (m³)CWTU
56[P1][B4] Consumption Monitor: EnergyWh4 Bytes13.10 active energy (Wh)CWTU
56[P1][B4] Consumption Monitor: EnergykWh4 Bytes13.13 active energy (kWh)CWTU
56[P1][B4] 14-Byte Text IndicatorUTF-8 Text String14 BytesCWTU
57[P1][B4] Consumption Monitor: CO₂kg CO₂2 BytesCWTU
58[P1][B4] Consumption Monitor: Request0=No Action; 1=Request1 Bit1.1 switchCRT
59[P1][B4] Consumption Monitor: Reset0=No Action; 1=Reset1 Bit1.15 resetCRT
60[P1][B5] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
60[P1][B5] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
60[P1][B5] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
60[P1][B5] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
60[P1][B5] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
60[P1][B5] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
60[P1][B5] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
60[P1][B5] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
60[P1][B5] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
60[P1][B5] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
60[P1][B5] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
60[P1][B5] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
60[P1][B5] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
60[P1][B5] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
60[P1][B5] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
60[P1][B5] Alarm TriggerTrigger1 Bit1.5 alarmCWU
60[P1][B5] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
60[P1][B5] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
60[P1][B5] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
60[P1][B5] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
60[P1][B5] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
60[P1][B5] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
60[P1][B5] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
60[P1][B5] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
60[P1][B5] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
60[P1][B5] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
60[P1][B5] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
60[P1][B5] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
60[P1][B5] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
60[P1][B5] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
60[P1][B5] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
60[P1][B5] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
60[P1][B5] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
60[P1][B5] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
60[P1][B5] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
60[P1][B5] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
60[P1][B5] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
61[P1][B5] Binary Control1-Bit Control1 Bit1.1 switchCRT
61[P1][B5] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
61[P1][B5] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
61[P1][B5] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
61[P1][B5] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
61[P1][B5] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
61[P1][B5] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
61[P1][B5] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
61[P1][B5] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
61[P1][B5] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
61[P1][B5] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
61[P1][B5] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
61[P1][B5] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
61[P1][B5] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
61[P1][B5] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
61[P1][B5] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
61[P1][B5] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
61[P1][B5] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
61[P1][B5] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
61[P1][B5] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
61[P1][B5] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
61[P1][B5] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Scaling)100%1 Byte5.1 percentage (0..100%)CRT
61[P1][B5] Fan Control (Enumerated)Auto, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)Auto, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)Auto, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)Auto, 1, 21 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)Auto, 11 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)0, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)0, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)0, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)0, 1, 21 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)0, 11 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)1, 2, 31 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)1, 21 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Fan Control (Enumerated)11 Byte5.10 counter pulses (0..255)CRT
61[P1][B5] Macro: Started0 = Macro Started; 1 = Nothing1 Bit1.1 switchCRT
61[P1][B5] Macro: Started0 = Nothing; 1 = Macro Started1 Bit1.1 switchCRT
62[P1][B5] Shutter - Stop/Step0=Stop/Step Up; 1=Stop/Step Down1 Bit1.7 stepCRT
62[P1][B5] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
62[P1][B5] Blue Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
62[P1][B5] Consumption Monitor: CostLocal Currency2 BytesCWTU
62[P1][B5] Chrono-thermostat: On/Off0 = Off; 1 = On1 Bit1.1 switchCRT
62[P1][B5] White Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
62[P1][B5] Holiday (1 Byte)0...2551 Byte5.10 counter pulses (0..255)CRT
62[P1][B5] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.3 enableCRWTU
62[P1][B5] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.3 enableCRWTU
63[P1][B5] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
63[P1][B5] Shutter Positioning (Only Macros)0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CRT
63[P1][B5] Precise Dimming (Only Macros)1-Byte Dimmer Control1 Byte5.1 percentage (0..100%)CRT
64[P1][B5] Consumption Monitor: Volumem³4 Bytes14.76 volume (m³)CWTU
64[P1][B5] Consumption Monitor: EnergyWh4 Bytes13.10 active energy (Wh)CWTU
64[P1][B5] Consumption Monitor: EnergykWh4 Bytes13.13 active energy (kWh)CWTU
64[P1][B5] 14-Byte Text IndicatorUTF-8 Text String14 BytesCWTU
65[P1][B5] Consumption Monitor: CO₂kg CO₂2 BytesCWTU
66[P1][B5] Consumption Monitor: Request0=No Action; 1=Request1 Bit1.1 switchCRT
67[P1][B5] Consumption Monitor: Reset0=No Action; 1=Reset1 Bit1.15 resetCRT
68[P1][B6] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
68[P1][B6] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
68[P1][B6] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
68[P1][B6] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
68[P1][B6] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
68[P1][B6] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
68[P1][B6] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
68[P1][B6] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
68[P1][B6] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
68[P1][B6] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
68[P1][B6] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
68[P1][B6] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
68[P1][B6] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
68[P1][B6] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
68[P1][B6] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
68[P1][B6] Alarm TriggerTrigger1 Bit1.5 alarmCWU
68[P1][B6] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
68[P1][B6] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
68[P1][B6] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
68[P1][B6] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
68[P1][B6] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
68[P1][B6] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
68[P1][B6] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
68[P1][B6] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
68[P1][B6] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
68[P1][B6] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
68[P1][B6] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
68[P1][B6] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
68[P1][B6] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
68[P1][B6] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
68[P1][B6] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
68[P1][B6] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
68[P1][B6] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
68[P1][B6] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
68[P1][B6] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
68[P1][B6] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
68[P1][B6] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
69[P1][B6] Binary Control1-Bit Control1 Bit1.1 switchCRT
69[P1][B6] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
69[P1][B6] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
69[P1][B6] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
69[P1][B6] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
69[P1][B6] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
69[P1][B6] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
69[P1][B6] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
69[P1][B6] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
69[P1][B6] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
69[P1][B6] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
69[P1][B6] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
69[P1][B6] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
69[P1][B6] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
69[P1][B6] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
69[P1][B6] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
69[P1][B6] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
69[P1][B6] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
69[P1][B6] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
69[P1][B6] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
69[P1][B6] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
69[P1][B6] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Scaling)100%1 Byte5.1 percentage (0..100%)CRT
69[P1][B6] Fan Control (Enumerated)Auto, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)Auto, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)Auto, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)Auto, 1, 21 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)Auto, 11 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)0, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)0, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)0, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)0, 1, 21 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)0, 11 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)1, 2, 31 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)1, 21 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Fan Control (Enumerated)11 Byte5.10 counter pulses (0..255)CRT
69[P1][B6] Macro: Started0 = Macro Started; 1 = Nothing1 Bit1.1 switchCRT
69[P1][B6] Macro: Started0 = Nothing; 1 = Macro Started1 Bit1.1 switchCRT
70[P1][B6] Shutter - Stop/Step0=Stop/Step Up; 1=Stop/Step Down1 Bit1.7 stepCRT
70[P1][B6] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
70[P1][B6] Blue Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
70[P1][B6] Consumption Monitor: CostLocal Currency2 BytesCWTU
70[P1][B6] Chrono-thermostat: On/Off0 = Off; 1 = On1 Bit1.1 switchCRT
70[P1][B6] White Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
70[P1][B6] Holiday (1 Byte)0...2551 Byte5.10 counter pulses (0..255)CRT
70[P1][B6] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.3 enableCRWTU
70[P1][B6] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.3 enableCRWTU
71[P1][B6] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
71[P1][B6] Shutter Positioning (Only Macros)0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CRT
71[P1][B6] Precise Dimming (Only Macros)1-Byte Dimmer Control1 Byte5.1 percentage (0..100%)CRT
72[P1][B6] Consumption Monitor: Volumem³4 Bytes14.76 volume (m³)CWTU
72[P1][B6] Consumption Monitor: EnergyWh4 Bytes13.10 active energy (Wh)CWTU
72[P1][B6] Consumption Monitor: EnergykWh4 Bytes13.13 active energy (kWh)CWTU
72[P1][B6] 14-Byte Text IndicatorUTF-8 Text String14 BytesCWTU
73[P1][B6] Consumption Monitor: CO₂kg CO₂2 BytesCWTU
74[P1][B6] Consumption Monitor: Request0=No Action; 1=Request1 Bit1.1 switchCRT
75[P1][B6] Consumption Monitor: Reset0=No Action; 1=Reset1 Bit1.15 resetCRT
76[P1][B7] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
76[P1][B7] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
76[P1][B7] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
76[P1][B7] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
76[P1][B7] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
76[P1][B7] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
76[P1][B7] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
76[P1][B7] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
76[P1][B7] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
76[P1][B7] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
76[P1][B7] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
76[P1][B7] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
76[P1][B7] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
76[P1][B7] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
76[P1][B7] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
76[P1][B7] Alarm TriggerTrigger1 Bit1.5 alarmCWU
76[P1][B7] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
76[P1][B7] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
76[P1][B7] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
76[P1][B7] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
76[P1][B7] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
76[P1][B7] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
76[P1][B7] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
76[P1][B7] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
76[P1][B7] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
76[P1][B7] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
76[P1][B7] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
76[P1][B7] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
76[P1][B7] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
76[P1][B7] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
76[P1][B7] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
76[P1][B7] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
76[P1][B7] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
76[P1][B7] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
76[P1][B7] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
76[P1][B7] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
76[P1][B7] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
77[P1][B7] Binary Control1-Bit Control1 Bit1.1 switchCRT
77[P1][B7] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
77[P1][B7] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
77[P1][B7] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
77[P1][B7] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
77[P1][B7] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
77[P1][B7] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
77[P1][B7] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
77[P1][B7] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
77[P1][B7] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
77[P1][B7] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
77[P1][B7] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
77[P1][B7] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
77[P1][B7] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
77[P1][B7] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
77[P1][B7] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
77[P1][B7] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
77[P1][B7] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
77[P1][B7] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
77[P1][B7] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
77[P1][B7] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
77[P1][B7] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Scaling)100%1 Byte5.1 percentage (0..100%)CRT
77[P1][B7] Fan Control (Enumerated)Auto, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)Auto, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)Auto, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)Auto, 1, 21 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)Auto, 11 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)0, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)0, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)0, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)0, 1, 21 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)0, 11 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)1, 2, 31 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)1, 21 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Fan Control (Enumerated)11 Byte5.10 counter pulses (0..255)CRT
77[P1][B7] Macro: Started0 = Macro Started; 1 = Nothing1 Bit1.1 switchCRT
77[P1][B7] Macro: Started0 = Nothing; 1 = Macro Started1 Bit1.1 switchCRT
78[P1][B7] Shutter - Stop/Step0=Stop/Step Up; 1=Stop/Step Down1 Bit1.7 stepCRT
78[P1][B7] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
78[P1][B7] Blue Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
78[P1][B7] Consumption Monitor: CostLocal Currency2 BytesCWTU
78[P1][B7] Chrono-thermostat: On/Off0 = Off; 1 = On1 Bit1.1 switchCRT
78[P1][B7] White Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
78[P1][B7] Holiday (1 Byte)0...2551 Byte5.10 counter pulses (0..255)CRT
78[P1][B7] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.3 enableCRWTU
78[P1][B7] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.3 enableCRWTU
79[P1][B7] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
79[P1][B7] Shutter Positioning (Only Macros)0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CRT
79[P1][B7] Precise Dimming (Only Macros)1-Byte Dimmer Control1 Byte5.1 percentage (0..100%)CRT
80[P1][B7] Consumption Monitor: Volumem³4 Bytes14.76 volume (m³)CWTU
80[P1][B7] Consumption Monitor: EnergyWh4 Bytes13.10 active energy (Wh)CWTU
80[P1][B7] Consumption Monitor: EnergykWh4 Bytes13.13 active energy (kWh)CWTU
80[P1][B7] 14-Byte Text IndicatorUTF-8 Text String14 BytesCWTU
81[P1][B7] Consumption Monitor: CO₂kg CO₂2 BytesCWTU
82[P1][B7] Consumption Monitor: Request0=No Action; 1=Request1 Bit1.1 switchCRT
83[P1][B7] Consumption Monitor: Reset0=No Action; 1=Reset1 Bit1.15 resetCRT
84[P1][B8] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
84[P1][B8] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
84[P1][B8] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
84[P1][B8] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
84[P1][B8] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
84[P1][B8] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
84[P1][B8] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
84[P1][B8] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
84[P1][B8] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
84[P1][B8] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
84[P1][B8] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
84[P1][B8] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
84[P1][B8] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
84[P1][B8] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
84[P1][B8] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
84[P1][B8] Alarm TriggerTrigger1 Bit1.5 alarmCWU
84[P1][B8] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
84[P1][B8] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
84[P1][B8] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
84[P1][B8] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
84[P1][B8] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
84[P1][B8] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
84[P1][B8] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
84[P1][B8] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
84[P1][B8] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
84[P1][B8] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
84[P1][B8] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
84[P1][B8] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
84[P1][B8] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
84[P1][B8] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
84[P1][B8] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
84[P1][B8] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
84[P1][B8] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
84[P1][B8] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
84[P1][B8] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
84[P1][B8] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
84[P1][B8] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
85[P1][B8] Binary Control1-Bit Control1 Bit1.1 switchCRT
85[P1][B8] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
85[P1][B8] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
85[P1][B8] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
85[P1][B8] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
85[P1][B8] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
85[P1][B8] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
85[P1][B8] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
85[P1][B8] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
85[P1][B8] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
85[P1][B8] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
85[P1][B8] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
85[P1][B8] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
85[P1][B8] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
85[P1][B8] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
85[P1][B8] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
85[P1][B8] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
85[P1][B8] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
85[P1][B8] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
85[P1][B8] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
85[P1][B8] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
85[P1][B8] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Scaling)100%1 Byte5.1 percentage (0..100%)CRT
85[P1][B8] Fan Control (Enumerated)Auto, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)Auto, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)Auto, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)Auto, 1, 21 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)Auto, 11 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)0, 1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)0, 1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)0, 1, 2, 31 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)0, 1, 21 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)0, 11 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)1, 2, 3, 4, 51 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)1, 2, 3, 41 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)1, 2, 31 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)1, 21 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Fan Control (Enumerated)11 Byte5.10 counter pulses (0..255)CRT
85[P1][B8] Macro: Started0 = Macro Started; 1 = Nothing1 Bit1.1 switchCRT
85[P1][B8] Macro: Started0 = Nothing; 1 = Macro Started1 Bit1.1 switchCRT
86[P1][B8] Shutter - Stop/Step0=Stop/Step Up; 1=Stop/Step Down1 Bit1.7 stepCRT
86[P1][B8] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
86[P1][B8] Blue Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
86[P1][B8] Consumption Monitor: CostLocal Currency2 BytesCWTU
86[P1][B8] Chrono-thermostat: On/Off0 = Off; 1 = On1 Bit1.1 switchCRT
86[P1][B8] White Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
86[P1][B8] Holiday (1 Byte)0...2551 Byte5.10 counter pulses (0..255)CRT
86[P1][B8] Fan Control - Auto ModeSwitch Auto Mode on Short Press1 Bit1.3 enableCRWTU
86[P1][B8] Fan Control - Auto ModeSwitch Auto Mode on Long Press1 Bit1.3 enableCRWTU
87[P1][B8] Light Dimming4-bit Dimming Control4 Bit3.7 dimming controlCRT
87[P1][B8] Shutter Positioning (Only Macros)0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CRT
87[P1][B8] Precise Dimming (Only Macros)1-Byte Dimmer Control1 Byte5.1 percentage (0..100%)CRT
88[P1][B8] Consumption Monitor: Volumem³4 Bytes14.76 volume (m³)CWTU
88[P1][B8] Consumption Monitor: EnergyWh4 Bytes13.10 active energy (Wh)CWTU
88[P1][B8] Consumption Monitor: EnergykWh4 Bytes13.13 active energy (kWh)CWTU
88[P1][B8] 14-Byte Text IndicatorUTF-8 Text String14 BytesCWTU
89[P1][B8] Consumption Monitor: CO₂kg CO₂2 BytesCWTU
90[P1][B8] Consumption Monitor: Request0=No Action; 1=Request1 Bit1.1 switchCRT
91[P1][B8] Consumption Monitor: Reset0=No Action; 1=Reset1 Bit1.15 resetCRT
92[P2][B1] Binary Indicator1-Bit Indicator1 Bit1.1 switchCWTU
92[P2][B1] Enumerated Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
92[P2][B1] 1-Byte Unsigned Int Indicator0...2551 Byte5.10 counter pulses (0..255)CWTU
92[P2][B1] 1-Byte Signed Int Indicator-128...1271 Byte6.10 counter pulses (-128..127)CWTU
92[P2][B1] Percentage Indicator0-100%1 Byte5.1 percentage (0..100%)CWTU
92[P2][B1] 2-Byte Unsigned Int Indicator0...655352 Bytes7.1 pulsesCWTU
92[P2][B1] 2-Byte Signed Int Indicator-32768...327672 Bytes8.1 pulses differenceCWTU
92[P2][B1] 2-Byte Float Indicator-671088.64...670433.282 BytesDPT.9CWTU
92[P2][B1] Shutter Position0%=Top; 100%=Bottom1 Byte5.1 percentage (0..100%)CWTU
92[P2][B1] Light Indicator0%=Off; 100%=On1 Byte5.1 percentage (0..100%)CWTU
92[P2][B1] Temperature IndicatorAbsolute Float Value2 Bytes9.1 temperature (°C)CWTU
92[P2][B1] Mode Indicator0 = Cool; 1 = Heat1 Bit1.100 cooling/heatingCWTU
92[P2][B1] Mode IndicatorHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCWTU
92[P2][B1] Special Mode IndicatorComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCWTU
92[P2][B1] Red Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
92[P2][B1] Alarm TriggerTrigger1 Bit1.5 alarmCWU
92[P2][B1] Weekly Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
92[P2][B1] Daily Timer Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
92[P2][B1] RGB ColorRed, Green and Blue Components3 Bytes232.600 RGB value 3x(0..255)CRWTU
92[P2][B1] Chrono-thermostat: Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
92[P2][B1] Consumption Monitor: PowerW4 Bytes14.56 power (W)CWTU
92[P2][B1] Consumption Monitor: PowerkW2 Bytes9.24 power (kW)CWTU
92[P2][B1] Consumption Monitor: Flowm³/s4 Bytes14.77 volume flux (m³/s)CWTU
92[P2][B1] Consumption Monitor: Flowl/h2 Bytes9.25 volume flow (l/h)CWTU
92[P2][B1] 4-Byte Float Indicator-3.403E+38...3.403E+384 BytesDPT.14CWTU
92[P2][B1] 4-Byte Signed Int Indicator-2147483648…21474836474 Bytes13.1 counter pulses (signed)CWTU
92[P2][B1] Fan Indicator0 - 100%1 Byte5.1 percentage (0..100%)CWTU
92[P2][B1] Fan IndicatorEnumerated Value1 Byte5.10 counter pulses (0..255)CWTU
92[P2][B1] Macro: Trigger0 = Start; 1 = Stop1 Bit1.1 switchCWU
92[P2][B1] Macro: Trigger0 = Stop; 1 = Start1 Bit1.1 switchCWU
92[P2][B1] Scheduler Enabling0 = Disabled; 1 = Enabled1 Bit1.3 enableCWTU
92[P2][B1] Logic Function: Trigger0 = Nothing; 1 = Evaluate1 Bit1.16 acknowledgeCWU
92[P2][B1] Logic Function: Trigger0 = Evaluate; 1 = Nothing1 Bit1.16 acknowledgeCWU
92[P2][B1] Daily Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
92[P2][B1] Chrono-thermostat: Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
92[P2][B1] Weekly Timer Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
92[P2][B1] Scheduler Enabling0 = Enabled; 1 = Disabled1 Bit1.3 enableCWTU
93[P2][B1] Binary Control1-Bit Control1 Bit1.1 switchCRT
93[P2][B1] 1-Byte Unsigned Int Control0...2551 Byte5.10 counter pulses (0..255)CRT
93[P2][B1] 1-Byte Signed Int Control-128...1271 Byte6.10 counter pulses (-128..127)CRT
93[P2][B1] Percentage Control0-100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] 2-Byte Unsigned Int Control0...655352 Bytes7.1 pulsesCRT
93[P2][B1] 2-Byte Signed Int Control-32768...327672 Bytes8.1 pulses differenceCRT
93[P2][B1] 2-Byte Float Control-671088.64...670433.282 BytesDPT.9CRT
93[P2][B1] Enumerated Control0...2551 Byte5.10 counter pulses (0..255)CRT
93[P2][B1] Move Shutter0=Up; 1=Down1 Bit1.8 up/downCRT
93[P2][B1] Light On/Off0=Off; 1=On1 Bit1.1 switchCRT
93[P2][B1] Temperature ControlAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
93[P2][B1] Temperature Offset ControlRelative Float Value2 Bytes9.2 temperature difference (K)CRWT
93[P2][B1] Temperature Offset Control0=Decrease; 1=Increase1 Bit1.7 stepCRT
93[P2][B1] Mode Control0=Cool; 1=Heat1 Bit1.100 cooling/heatingCRT
93[P2][B1] Mode ControlHeat, Cool, Auto, Fan and Dry1 Byte20.105 HVAC control modeCRT
93[P2][B1] Special Mode ControlComfort, Standby, Economy, Building Protection and Auto1 Byte20.102 HVAC modeCRT
93[P2][B1] Green Channel0-100%1 Byte5.1 percentage (0..100%)CRWTU
93[P2][B1] Daily Timer Control1-Bit Control1 Bit1.1 switchCRT
93[P2][B1] Weekly Timer Control1-Bit Control1 Bit1.1 switchCRT
93[P2][B1] Alarm Confirmation0=No Action; 1=Confirm1 Bit1.16 acknowledgeCWTU
93[P2][B1] Chrono-thermostat: Temperature SetpointAbsolute Float Value2 Bytes9.1 temperature (°C)CRT
93[P2][B1] Holiday (1 bit)0 = Holiday; 1 = Workday1 Bit1.2 booleanCRT
93[P2][B1] Holiday (1 bit)0 = Workday; 1 = Holiday1 Bit1.2 booleanCRT
93[P2][B1] Fan Control (1-Bit)0 = Decrease; 1 = Increase1 Bit1.7 stepCRT
93[P2][B1] Fan Control (Scaling)Auto, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)Auto, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)Auto, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)Auto, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)Auto, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)0%, 25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)0%, 33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)0%, 50%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)0%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)0%, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)25%, 50%, 75%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)33%, 67%, 100%1 Byte5.1 percentage (0..100%)CRT
93[P2][B1] Fan Control (Scaling)50%, 100%1 Byte5.1 percentage (0..100%)CRT

First 1000 of 11045 group objects shown. Download the .knxprod for the full list.

Parameters (631)
ParameterTypeDefault
IP Address AssigmentlistDHCP
Device Descriptiontext
Temperature Sensor CALIBRATIONsignedInt -50…500
Temperature Sending PERIOD (0 = Disabled)unsignedInt 0…10060
Send with a Temperature Change (0 = Disabled)unsignedInt 0…2000
- Default Password (1)unsignedInt 0…91
- Default Password (2)unsignedInt 0…92
- Default Password (3)unsignedInt 0…93
- Default Password (4)unsignedInt 0…94
Weekdays Initials [e.g. MTWTFSS]textMTWTFSS
- Label for "Enter Password"textEnter Password
- Label for "Error"textERROR
- Label for "New Password"textNew Password
- Label for "Repeat Password"textRepeat Password
- Label for "Updated"textUpdated
IP AddressipAddress192.168.1.100
Subnet MaskipAddress255.255.255.0
Power Supply Voltagelist12 V.
Default Theme (after Programming)listOcean
Page 1unsignedInt 0…2550
Automatic Page ShapinglistNo
ProtectedlistNo
Box 1unsignedInt 0…2550
Labeltext
VisualizationlistIndicator
Left ButtonlistOff 1
Right ButtonlistOn 1
FunctionlistBinary Indicator (Icon)
FunctionlistBinary Control
FunctionlistBinary Control (Icon)
FunctionlistRGB Control
FunctionlistSetpoint Control
Off IconlistOff 1
On IconlistOn 1
Off Texttext
On Texttext
# Enumslist1
Icon 1listOff 1
Icon 2listOff 1
Icon 3listOff 1
Icon 4listOff 1
Icon 5listOff 1
Icon 6listOff 1
Value 1unsignedInt 0…2550
Value 2unsignedInt 0…2550
Value 3unsignedInt 0…2550
Value 4unsignedInt 0…2550
Value 5unsignedInt 0…2550
Value 6unsignedInt 0…2550
Text 2text
Text 1text
Text 3text
Text 4text
Text 6text
Text 5text
Save Log?listNo
Unittext
ActionlistToggle
Constant ValueunsignedInt 0…2550
Constant ValuesignedInt -128…1270
Constant ValueunsignedInt 0…655350
Constant ValuesignedInt -32768…327670
Constant Valuefloat -671088.64…670433.280
Scene NumberunsignedInt 1…641
ActionlistRun
Constant ValueunsignedInt 0…1000
ActionlistLeft 0, Right 1
ActionlistLeft Decrease, Right Increase
Minimum ValueunsignedInt 0…2550
Maximum ValueunsignedInt 0…255255
Initial ValueunsignedInt 0…2550
Increment ShortunsignedInt 1…2551
Increment LongunsignedInt 1…25510
Minimum ValuesignedInt -128…127-128
Maximum ValuesignedInt -128…127127
Initial ValuesignedInt -128…1270
Increment ShortunsignedInt 1…1271
Increment LongunsignedInt 1…12710
Minimum ValueunsignedInt 0…1000
Maximum ValueunsignedInt 0…100100
Initial ValueunsignedInt 0…1000
Increment ShortunsignedInt 1…1001
Increment LongunsignedInt 1…10010
Minimum ValueunsignedInt 0…655350
Maximum ValueunsignedInt 0…6553565535
Initial ValueunsignedInt 0…655350
Increment ShortunsignedInt 1…655351
Increment LongunsignedInt 1…6553510
Increment LongunsignedInt 1…3276710
Increment ShortunsignedInt 1…327671
Initial ValuesignedInt -32768…327670
Maximum ValuesignedInt -32768…3276732767
Minimum ValuesignedInt -32768…32767-32768
Minimum Valuefloat -671088.64…670433.28670433.28
Maximum Valuefloat -671088.64…670433.28-671088.64
Initial Valuefloat -671088.64…670433.280
Increment Shortfloat 0.1…670433.280.5
Increment Longfloat 0.1…670433.281
Left SceneunsignedInt 1…641
Right SceneunsignedInt 1…641
ActionlistRun and Save
ActionlistLeft Down, Right Up
ActionlistLeft Off, Right On
Dimming Steplist100%
Setpoint TypelistAbsolute
Minimum ValuesignedInt -20…9510
Maximum ValuesignedInt -20…9530
Minimum OffsetsignedInt -15…0-10
Maximum OffsetsignedInt 0…1510
OffsetunsignedInt 1…2555
Mode TypelistHeat/Cool
AutounsignedInt 0…2551
CoolunsignedInt 0…2551
HeatunsignedInt 0…2551
FanunsignedInt 0…2551
DryunsignedInt 0…2551
Allow Protection ModelistNo
Object TypelistThree Single Colour Objects (DPT 5.001)
Measurement TypelistPower
Timer Typelist1-Bit Value
Triggerlist1
Periodic MonitoringlistNo
Cycle Time [x 1min]unsignedInt 1…2551
Button IconlistOn 1
Button IconlistOff 1
Button (In the Middle)listOff 1
Security LevelslistOne Level
- Default Password (4)unsignedInt 0…98
- Default Password (3)unsignedInt 0…97
- Default Password (2)unsignedInt 0…96
- Default Password (1)unsignedInt 0…95
- Label for "Password 2"textEnter Password
- Label for "Password 1"textEnter Password
Configuration PageunsignedInt 0…2551
Automatic Page ShapinglistYes
Time/DateunsignedInt 0…2551
DeviceunsignedInt 0…2551
Program ConfigurationunsignedInt 0…2550
KNXunsignedInt 0…2551
Program VersionunsignedInt 0…2551
IP AddressunsignedInt 0…2551
MAC AddressunsignedInt 0…2551
Alarm LogunsignedInt 0…2550
Default PagelistMenu
Show TimelistYes
Show TemperaturelistInternal Temperature Probe
Welcome Back Object (1-Bit)unsignedInt 0…2550
Valuelist1
Time to Activate the Welcome ObjectunsignedInt 1…2551
Touch Lockinglist0=Unlocked; 1=Locked
IconlistHome
Energy ConsumptionunsignedInt 0…2550
CO2unsignedInt 0…2550
CostunsignedInt 0…2550
Currency Symboltext
Remote Control Through the InternetunsignedInt 0…2550
USB UpdatinglistEnabled
Password (1)unsignedInt 0…90
Password (2)unsignedInt 0…90
Password (3)unsignedInt 0…90
Password (4)unsignedInt 0…90
Network UpdatinglistEnabled
Device PairingunsignedInt 0…2550
Time/Date Sending PeriodunsignedInt 0…6553510
Minimum Setpoint ValuesignedInt -20…9518
Maximum Setpoint ValuesignedInt -20…9530
Input 1listDisabled
Input 2listDisabled
InputsunsignedInt 0…10
Parameters versiontextV1.2 JE Pro
Check HWlist
Valuelist0 = Workday; 1 = Holiday
Send SceneunsignedInt 0…2550
Scene Number (Workday)unsignedInt 0…640
Scene Number (Holiday)unsignedInt 0…640
Send 1-Byte ObjectunsignedInt 0…2550
Value (Workday)unsignedInt 0…2550
Value (Holiday)unsignedInt 0…2550
Sending FrecuencylistEveryday
Power UnitlistkW
Energy UnitlistkWh
Flow Unitlistl/h
VolumeunsignedInt 0…2550
Send 1-Bit ObjectunsignedInt 0…2551
Speed Levelslist2
Control Typelist1 bit (Decrease/Increase)
CyclicalunsignedInt 0…2550
Auto ModeunsignedInt 0…2550
Dedicated Object for Auto ModeunsignedInt 0…2550
Value to Set Auto ModelistSend 0 to Set Auto Mode
Long Press to Activate Auto ModeunsignedInt 0…2550
Allow Speed 0unsignedInt 0…2550
Allow Speed 0 (Auto)unsignedInt 0…2550
pg[0].box[0].uConfig.fan.byteRangelistAuto
Programming ButtonunsignedInt 0…2551
ResetunsignedInt 0…2551
Reset TypelistParameters Reset
ProfileunsignedInt 0…2551
BrightnessunsignedInt 0…2551
ContrastunsignedInt 0…2551
MelodyunsignedInt 0…2551
ThemeunsignedInt 0…2551
Error LogunsignedInt 0…2550
Probe CalibrationunsignedInt 0…2550
First WeekdaylistMonday
January LabeltextJANUARY
February LabeltextFEBRUARY
March LabeltextMARCH
April LabeltextAPRIL
May LabeltextMAY
June LabeltextJUNE
July LabeltextJULY
August LabeltextAUGUST
September LabeltextSEPTEMBER
October LabeltextOCTOBER
November LabeltextNOVEMBER
December LabeltextDECEMBER
Label for "Time ON"textTime ON
Label for "Time OFF"textTime OFF
Label for "Scene"textScene
Last 6 HoursunsignedInt 0…2551
Last DayunsignedInt 0…2551
Last WeekunsignedInt 0…2551
Last MonthunsignedInt 0…2551
Last YearunsignedInt 0…2551
Draw Max ValueunsignedInt 0…2551
Draw Min ValueunsignedInt 0…2551
Normal ModeunsignedInt 0…2551
Backlight Level - ActiveunsignedInt 0…100100
Change ThemelistNo Change
Backlight AttenuationlistTurn Off the Screen After a Long Time of Inactivity
Night ModeunsignedInt 0…2550
Backlight LevelunsignedInt 0…10050
Control Object: 1-BitunsignedInt 0…2551
Valuelist0 = Normal Mode; 1 = Night Mode
Control Object: SceneunsignedInt 0…2550
Scene Number (Normal Mode)unsignedInt 0…640
Scene Number (Night Mode)unsignedInt 0…640
Backlight Mode after ETS DownloadlistNormal Mode
Light Up when the Screen is PressedunsignedInt 0…2550
Backlight Level after TouchunsignedInt 0…10075
Length of LightingunsignedInt 1…6553510
ProtectlistOnly Configuration Button
Protect againlistAfter a Time Period or a Page Switch
TimeunsignedInt 1…655356
Trigger Objectlist1-Bit Object
Valuelist0=Stop; 1=Start
Scene Number (Start)unsignedInt 0…640
Scene Number (Stop)unsignedInt 0…640
Send Object when Macro StartslistDisabled
SceneunsignedInt 1…641
Trigger Object Valuelist0=Nothing; 1=Evaluate
Additional ConditionlistNo Additional Condition
Number of Condition Objectslist1
TemperatureunsignedInt 0…2551
ImageunsignedInt 0…2550
Activation TimeoutunsignedInt 3…6553512
Time of DayunsignedInt 0…2550
TemperatureunsignedInt 0…2550
ScreensaverunsignedInt 0…2550
Welcome GreetingunsignedInt 0…2550
Attenuate DisplayunsignedInt 0…2550
Temperature fromlistInternal Temperature Probe
Line 1listFixed
TexttextWelcome Mr/Mrs.
Line 2listReceived from text Object
Texttext
Line 3listFixed
TexttextTouch the screen
Line 4listFixed
Update ObjectslistDisabled
DelayunsignedInt 0…6553510
Thermostat 1unsignedInt 0…2550
Thermostat 2unsignedInt 0…2550
Page NumberunsignedInt 1…121
Welcome Back ObjectunsignedInt 0…2550
Welcome Back Object (Scene)unsignedInt 0…2550
"Page Name" LabeltextPAGE NAME
"Box Name" LabeltextBOX NAME
"Value" LabeltextVALUE
"Hour" LabeltextHOUR
"Calendar Name" LabeltextCALENDAR NAME
"Day Type" LabeltextDAY TYPE
Off ButtonlistOff 1
On ButtonlistOn 1
Allow Auto ModelistNo
State IndicatorunsignedInt 0…2551
Increment ShortunsignedInt 1…201
Increment LongunsignedInt 1…202
IncrementunsignedInt 1…201
"No Calendar" LabeltextNO CALENDAR
"Workday" LabeltextWORKDAY
"Holiday" LabeltextHOLIDAY
Screen OrientationlistVertical
Titletext
Title (Line 1)text
Title (Line 2)text
Select Languagelisten
Enablementlist0=Disable; 1=Enable
Synchronize Time/Date via NTPunsignedInt 0…2550
Time Zonelist(UTC) Coordinated Universal Time
NTP Servertext0.pool.ntp.org
Main LanguageunsignedInt 0…2551
Language 2unsignedInt 0…2550
Select Languagelistes
Language 3unsignedInt 0…2550
Select Languagelistde
Language 4unsignedInt 0…2550
Select Languagelistfr
Language 5unsignedInt 0…2550
Select Languagelistit
Scale After ProgramminglistCelsius (ºC)
Object to Change the Temperature ScaleunsignedInt 0…2551
Length of Lighting - ActiveunsignedInt 1…655356
Length of Lighting - Attenuation 1unsignedInt 1…655356
Length of Lighting - Attenuation 2unsignedInt 1…6553518
Run Welcome Greeting with Text Object UpdateunsignedInt 0…2550
Temperature Sending Period (0 = Disabled)unsignedInt 0…65535600
Temperature Sensor CalibrationsignedInt -50…500
Send with a Temperature Change (0 = Disabled)unsignedInt 0…2550
Temperature ProtectionlistNo
Overheating Temp.signedInt -30…12540
Overcooling Temp.signedInt -30…12510
HysteresisunsignedInt 1…20020
PeriodunsignedInt 1…655351
Heartbeat (Periodic Alive Notification)unsignedInt 0…2550
Probe TypelistZennio Probe
Debounce TimeunsignedInt 10…25520
TypelistPush Button
Long Press TimeunsignedInt 1…505
Double Press TimeunsignedInt 1…505
Double PressunsignedInt 0…2550
ActionlistNo Action
ActionlistSending of 0/1
ResponselistSwitching 0/1
Periodic Response SendinglistNo
ResponselistUp
ResponselistLight On
ResponselistRun Scene
ResponseunsignedInt 0…2550
ResponseunsignedInt 0…1000
ResponseunsignedInt 0…655350
Responsefloat -671088.64…670433.280
Sending PeriodunsignedInt 1…2551
Sending PeriodunsignedInt 1…181
DelayunsignedInt 0…2550
DelayunsignedInt 0…180
ResponselistDarker
SecurityunsignedInt 0…2550
Switch/Sensor TypelistN.O. (Parallel Resistor)
Resistor Valuelist2.2 kohm
Rising Edgelist1
Falling Edgelist0
Periodic Sending of "0" (0 = Disabled)unsignedInt 0…2550
Periodic Sending of "0" (0 = Disabled)unsignedInt 0…180
Periodic Sending of "1" (0 = Disabled)unsignedInt 0…2550
Periodic Sending of "1" (0 = Disabled)unsignedInt 0…180
Sending of "0" DelayunsignedInt 0…2550
Sending of "0" DelayunsignedInt 0…180
Sending of "1" DelayunsignedInt 0…2550
Sending of "1" DelayunsignedInt 0…180
Resend Last Edge Action on Bus Voltage RecoveryunsignedInt 0…2550
Sending DelayunsignedInt 2…2552
Evaluate the Input State after Unlock or ResetunsignedInt 0…2551
Edge TypelistRising Edge
Counter Sizelist1-Byte
Sending TypelistPeriodic
Periodic SendingunsignedInt 1…2551
Periodic SendingunsignedInt 1…181
Final ValueunsignedInt 1…255255
Final ValueunsignedInt 1…6553565535
VersionlistStandard Type
Short PressunsignedInt 0…2550
Long PressunsignedInt 0…2550
Luminosity SendingunsignedInt 0…2550
Period (0 = Disabled)unsignedInt 0…25515
Luminosity Change to Send (0 = Disabled)unsignedInt 0…1000
Channel 1unsignedInt 0…2550
Length of DetectionunsignedInt 1…25510
Length of DetectionunsignedInt 1…2551
Length of DetectionunsignedInt 1…181
Blind TimeunsignedInt 0…180
Blind TimeunsignedInt 0…2550
Reset Luminosity after No DetectionunsignedInt 0…2550
Reset DelayunsignedInt 0…600
Channel EnablementlistAlways Enabled
Configurationlist0 = Disable; 1 = Enable
Scene to DisableunsignedInt 1…642
Scene to EnableunsignedInt 1…641
Send when DisablinglistNothing
Send when EnablinglistNothing
Time to EnableunsignedInt 0…2550
Initial State (after reset)listLast state
Restricted by luminosity (only enabled under the threshold)unsignedInt 0…2550
ThresholdunsignedInt 1…10050
Send No Detection when the threshold is exceeded?unsignedInt 0…2550
Force StateunsignedInt 0…2550
Idle time after forceunsignedInt 1…25510
Idle time after forceunsignedInt 1…2551
Idle time after forceunsignedInt 1…181
Sending ModelistOnce
PeriodunsignedInt 1…181
PeriodunsignedInt 1…2551
PeriodunsignedInt 1…2555
Binary ValueunsignedInt 0…2551
Presence DetectorunsignedInt 0…2550
Trigger Valuelist0 = Closed Door; 1 = Open Door
Waiting TimeunsignedInt 0…655352
Listening TimeunsignedInt 1…655353
TypelistMaster
External Motion Sensor ObjectunsignedInt 0…2550
Channel 2unsignedInt 0…2550
Channel 3unsignedInt 0…2550
Number of sensors connected to the inputlistOne sensor
False Non-Occupied DetectionunsignedInt 0…2550
Luminosity ParametersunsignedInt 0…2551
Status when EnablinglistNo Change
Status when DisablinglistNo Change
Presence Detection EnablementlistAlways Enabled
SceneunsignedInt 0…2550
ScalingunsignedInt 0…2550
HVAC ModeunsignedInt 0…2550
ValuelistOn
ValueunsignedInt 1…641
ValueunsignedInt 0…100100
ValuelistComfort
ValuelistOff
ValueunsignedInt 0…1000
ValuelistStandby
Day/NightunsignedInt 0…2550
Configurationlist0 = Day; 1 = Night
Occupancy State ObjectunsignedInt 0…2550
Reference TemperaturelistTemperature Source 1
Setpoint Working Mode (see user manual)listRelative setpoints
1-bit Objects Working Mode (see user manual)listDisabled
Default ModelistEconomy
Comfort Prolongation TimeunsignedInt 10…25530
Permanently apply change to basic setpoint shiftlistYes
Maximum OffsetsignedInt 0…205
Minimum OffsetsignedInt -20…0-5
Comfort Offset (Heating)signedInt -100…00
Standby Offset (Heating)signedInt -100…0-30
Economy Offset (Heating)signedInt -100…0-50
Overheating Protection SetpointunsignedInt 25…12035
Freezing Protection SetpointsignedInt -10…157
Thermostat FunctionlistHeating
H/C Automatic ChangeoverlistDisabled
H/C Mode After ProgramminglistHeating
Additional Cooling BandsignedInt 5…10025
Additional Heating BandsignedInt -100…-5-25
Control Methodlist2-Point Control
Upper HysteresisunsignedInt 1…20010
Lower HysteresisunsignedInt 1…20010
Control TypelistContinuous (1 byte)
Control ParameterslistCooling Ceiling (5K/240min)
Control ParameterslistWarm Water (5K/150min)
Proportional BandunsignedInt 1…154
Integral TimeunsignedInt 5…255150
Restart accumulated error on saturation?listYes
PI CycleunsignedInt 1…25515
Thermostat always ON?listNo
Startup Setting (on bus voltage recovery)listLast (before Bus failure)
Initial Setpoint (after programming)signedInt -20…10022
Sending statuses on bus voltage recoverylistNo
Sending DelayunsignedInt 0…2550
Comfort Setpoint (Heating)signedInt -20…10021
Comfort Setpoint (Cooling)signedInt -20…10023
Standby Offset (Cooling)signedInt 0…10030
Economy Offset (Cooling)signedInt 0…10050
Permanently apply change to special mode setpointlistYes
Basic Setpoint (after programming)signedInt -20…10022
Additional CoolinglistNo
Additional HeatinglistNo
Automatic ON when a new special mode arriveslistDisabled
Comfort ProlongationlistDisabled
Window StatuslistDisabled
Initial Mode (after programming)listEconomy
Resending Period (0 = Disabled)unsignedInt 0…2550
Control VariableslistIndependent objects for heating and cooling
Send both H/C control signals periodically?listNo
Comfort Prolongation TimeunsignedInt 1…2551
PI CycleunsignedInt 10…25560
Resending Period (0 = Disabled)unsignedInt 0…180
PWM Minimum TimeunsignedInt 1…3010
If the switching time is lower than the minimumlistSwitch the control signal using the minimum time
Comfort Offset (Cooling)signedInt 0…1000
After a special mode change?listYes
After a H/C mode change?listNo
After a setpoint change?listNo
Lower Dead BandunsignedInt 0…10010
Upper Dead BandunsignedInt 0…10010
Thermostat TypelistAdvanced
ScenesunsignedInt 0…10
Scene 1unsignedInt 0…10
On/OfflistDo not change
H/C ModelistDo not change
Setpoint ValuesignedInt -20…10022
SetpointlistDo not change
Scene 2unsignedInt 0…10
Scene 3unsignedInt 0…10

First 500 of 631 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Z41 Pro 3.6 3.6 latest$51817D872026-11-253.8 MBDownload

About this file

This is the official ETS product database for the Zennio Z41 Pro (ZVI-Z41PRO), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.