01542 Dali gateway 1 channel 01542
VIMAR · Order number 01542 · Lighting Control › DALI Gateways and Light Controllers
Dali gateway 1 Kanal KNX
Download .knxprod Dali gateway 1 channel KNX 1.0 · 777 KB
Product
| Manufacturer | VIMAR |
|---|---|
| Product name | 01542 Dali gateway 1 channel |
| Order number | 01542 |
| Product text | 01542 Dali gateway 1 Kanal |
| Hardware | 01542 Dali gateway 1 Kanal |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Width (mm) | 70 |
| Registration | Registered · 2017-06-23 |
| Languages | de-DE, en-US, it-IT |
| Catalog entry | M-002C_H-01542-0-O0002_HP-A0AA-10-A8BB-O0002_CI-01542-1 |
| Fingerprint | A8BB |
| SHA-256 | 5d025a975e7d0a83dcffe5e031a82c33011de78427ab5ea96c0d1eb8e0bbc38f |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Dali gateway 1 Kanal KNX 1.0
| Application number | $A0AA |
|---|---|
| Version | 1.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 9519 |
| Group objects | 1726 |
Group objects (1726)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Allgemein | In Betrieb | 1 Bit | 1.2 boolean | CRT |
| 2 | Allgemein | Man.Bed. Sperren/Status | 1 Bit | 1.3 enable | CRWT |
| 3 | Allgemein | Störung Gateway-Betriebspannung | 1 Bit | 1.5 alarm | CRT |
| 4 | Allgemein | Störung Gateway-Betriebspannung quittieren | 1 Bit | 1.15 reset | CW |
| 5 | Allgemein | Statuswert anfordern | 1 Bit | 1.17 trigger | CW |
| 6 | Ausgang A | Statusbyte | 2 Bytes | CRT | |
| 7 | Ausgang A | DALI Adressenvergabe auslösen | 1 Bit | 1.3 enable | CW |
| 8 | Ausgang A | DALI Adressen überwachen | 1 Bit | 1.10 start/stop | CW |
| 9 | Ausgang A | Flexible Dimmzeit/Fade Time (Zeit 100ms) | 2 Bytes | 7.4 time (100 ms) | CRW |
| 9 | Ausgang A | Flexible Dimmzeit/Fade Time (DALI-Form [0..15]) | 1 Byte | 20.602 dali fade time | CRW |
| 9 | Ausgang A | Flexible Dimmzeit/Fade Time (Zeit 1s) | 2 Bytes | 7.5 time (s) | CRW |
| 10 | Ausgang A | Schalten | 1 Bit | 1.1 switch | CW |
| 11 | Ausgang A | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 12 | Ausgang A | Fkt. Ausschalthelligkeit aktivieren/Status | 1 Bit | 1.3 enable | CRWT |
| 13 | Ausgang A | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 14 | Ausgang A | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 15 | Ausgang A | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | Ausgang A | Status Schalten adressiert | 2 Bytes | CRWT | |
| 17 | Ausgang A | Status Helligkeitswert adressiert | 2 Bytes | CRWT | |
| 18 | Ausgang A | Störung DALI Spannung | 1 Bit | 1.5 alarm | CRT |
| 19 | Ausgang A | Störung Lampe | 1 Bit | 1.5 alarm | CRT |
| 20 | Ausgang A | Störung EVG | 1 Bit | 1.5 alarm | CRT |
| 21 | Ausgang A | Störung adressiert | 2 Bytes | 237.600 diagnostic value | CRWT |
| 22 | Ausgang A | Störung Anzahl Statistik | 4 Bytes | CRT | |
| 23 | Ausgang A | Störung EVG Anzahl | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 24 | Ausgang A | Störung EVG Nummer | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 25 | Ausgang A | Störung EVG weiterschalten | 1 Bit | 1.8 up/down | CW |
| 26 | Ausgang A | Störung Gruppe Anzahl | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 27 | Ausgang A | Störung Gruppe Nummer | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 28 | Ausgang A | Störung Gruppe weiterschalten | 1 Bit | 1.8 up/down | CW |
| 29 | Ausgang A | Störmeldungen quittieren/Status | 1 Bit | 1.15 reset | CRWT |
| 30 | Ausgang A | Störmeldungen sperren/Status | 1 Bit | 1.3 enable | CRW |
| 31 | Ausgang A | Teilausfall aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 31 | Ausgang A | Status Teilausfall aktiv | 1 Bit | 1.10 start/stop | CRT |
| 33 | Ausgang A | Szene 1...16 | 1 Byte | 18.1 scene control | CW |
| 34 | Ausgang A | Lampen einbrennen/Status | 1 Bit | 1.1 switch | CRWT |
| 35 | Ausgang A | Rest Einbrennzeit | 3 Bytes | CRWT | |
| 38 | Ausgang A | Slave Offset aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 39 | Ausgang A | Autom. Notlicht-Prüfungen synchronisieren | 1 Bit | 1.10 start/stop | CWT |
| 40 | Ausgang A | Notlicht-Prüfung starten adr. (CTC) | 2 Bytes | CWT | |
| 40 | Ausgang A | Notlicht-Prüfung starten adr. (DGN/S) | 2 Bytes | CWT | |
| 41 | Ausgang A | Notlicht-Prüfung Status adr. | 2 Bytes | CRWT | |
| 42 | Ausgang A | Notlicht-Prüfung Ergebnis adr. | 4 Bytes | CRWT | |
| 43 | Ausgang A | Alle Notlicht-Prüfungen stoppen | 1 Bit | 1.10 start/stop | CW |
| 44 | Ausgang A | Notlicht Rest/Inhibit-Mode aktivieren | 1 Bit | 1.10 start/stop | CW |
| 44 | Ausgang A | Notlicht Rest/Inhibit-Mode aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 48 | Ausgang A - Gruppe 1 | Statusbyte | 2 Bytes | CRT | |
| 49 | Ausgang A - Gruppe 1 | Schalten | 1 Bit | 1.1 switch | CW |
| 50 | Ausgang A - Gruppe 1 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 51 | Ausgang A - Gruppe 1 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 52 | Ausgang A - Gruppe 1 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 53 | Ausgang A - Gruppe 1 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 54 | Ausgang A - Gruppe 1 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 55 | Ausgang A - Gruppe 1 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 55 | Ausgang A - Gruppe 1 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 55 | Ausgang A - Gruppe 1 | Sperren | 1 Bit | 1.3 enable | CRW |
| 56 | Ausgang A - Gruppe 1 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 56 | Ausgang A - Gruppe 1 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 57 | Ausgang A - Gruppe 1 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 57 | Ausgang A - Gruppe 1 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 57 | Ausgang A - Gruppe 1 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 57 | Ausgang A - Gruppe 1 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 58 | Ausgang A - Gruppe 1 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 59 | Ausgang A - Gruppe 2 | Statusbyte | 2 Bytes | CRT | |
| 60 | Ausgang A - Gruppe 2 | Schalten | 1 Bit | 1.1 switch | CW |
| 61 | Ausgang A - Gruppe 2 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 62 | Ausgang A - Gruppe 2 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 63 | Ausgang A - Gruppe 2 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 64 | Ausgang A - Gruppe 2 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 65 | Ausgang A - Gruppe 2 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 66 | Ausgang A - Gruppe 2 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 66 | Ausgang A - Gruppe 2 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 66 | Ausgang A - Gruppe 2 | Sperren | 1 Bit | 1.3 enable | CRW |
| 67 | Ausgang A - Gruppe 2 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 67 | Ausgang A - Gruppe 2 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 68 | Ausgang A - Gruppe 2 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 68 | Ausgang A - Gruppe 2 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 68 | Ausgang A - Gruppe 2 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 68 | Ausgang A - Gruppe 2 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 69 | Ausgang A - Gruppe 2 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 70 | Ausgang A - Gruppe 3 | Statusbyte | 2 Bytes | CRT | |
| 71 | Ausgang A - Gruppe 3 | Schalten | 1 Bit | 1.1 switch | CW |
| 72 | Ausgang A - Gruppe 3 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 73 | Ausgang A - Gruppe 3 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 74 | Ausgang A - Gruppe 3 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 75 | Ausgang A - Gruppe 3 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 76 | Ausgang A - Gruppe 3 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 77 | Ausgang A - Gruppe 3 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 77 | Ausgang A - Gruppe 3 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 77 | Ausgang A - Gruppe 3 | Sperren | 1 Bit | 1.3 enable | CRW |
| 78 | Ausgang A - Gruppe 3 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 78 | Ausgang A - Gruppe 3 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 79 | Ausgang A - Gruppe 3 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 79 | Ausgang A - Gruppe 3 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 79 | Ausgang A - Gruppe 3 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 79 | Ausgang A - Gruppe 3 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 80 | Ausgang A - Gruppe 3 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 81 | Ausgang A - Gruppe 4 | Statusbyte | 2 Bytes | CRT | |
| 82 | Ausgang A - Gruppe 4 | Schalten | 1 Bit | 1.1 switch | CW |
| 83 | Ausgang A - Gruppe 4 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 84 | Ausgang A - Gruppe 4 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 85 | Ausgang A - Gruppe 4 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 86 | Ausgang A - Gruppe 4 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 87 | Ausgang A - Gruppe 4 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 88 | Ausgang A - Gruppe 4 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 88 | Ausgang A - Gruppe 4 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 88 | Ausgang A - Gruppe 4 | Sperren | 1 Bit | 1.3 enable | CRW |
| 89 | Ausgang A - Gruppe 4 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 89 | Ausgang A - Gruppe 4 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 90 | Ausgang A - Gruppe 4 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 90 | Ausgang A - Gruppe 4 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 90 | Ausgang A - Gruppe 4 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 90 | Ausgang A - Gruppe 4 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 91 | Ausgang A - Gruppe 4 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 92 | Ausgang A - Gruppe 5 | Statusbyte | 2 Bytes | CRT | |
| 93 | Ausgang A - Gruppe 5 | Schalten | 1 Bit | 1.1 switch | CW |
| 94 | Ausgang A - Gruppe 5 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 95 | Ausgang A - Gruppe 5 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 96 | Ausgang A - Gruppe 5 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 97 | Ausgang A - Gruppe 5 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 98 | Ausgang A - Gruppe 5 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 99 | Ausgang A - Gruppe 5 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 99 | Ausgang A - Gruppe 5 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 99 | Ausgang A - Gruppe 5 | Sperren | 1 Bit | 1.3 enable | CRW |
| 100 | Ausgang A - Gruppe 5 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 100 | Ausgang A - Gruppe 5 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 101 | Ausgang A - Gruppe 5 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 101 | Ausgang A - Gruppe 5 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 101 | Ausgang A - Gruppe 5 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 101 | Ausgang A - Gruppe 5 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 102 | Ausgang A - Gruppe 5 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 103 | Ausgang A - Gruppe 6 | Statusbyte | 2 Bytes | CRT | |
| 104 | Ausgang A - Gruppe 6 | Schalten | 1 Bit | 1.1 switch | CW |
| 105 | Ausgang A - Gruppe 6 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 106 | Ausgang A - Gruppe 6 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 107 | Ausgang A - Gruppe 6 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 108 | Ausgang A - Gruppe 6 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 109 | Ausgang A - Gruppe 6 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 110 | Ausgang A - Gruppe 6 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 110 | Ausgang A - Gruppe 6 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 110 | Ausgang A - Gruppe 6 | Sperren | 1 Bit | 1.3 enable | CRW |
| 111 | Ausgang A - Gruppe 6 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 111 | Ausgang A - Gruppe 6 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 112 | Ausgang A - Gruppe 6 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 112 | Ausgang A - Gruppe 6 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 112 | Ausgang A - Gruppe 6 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 112 | Ausgang A - Gruppe 6 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 113 | Ausgang A - Gruppe 6 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 114 | Ausgang A - Gruppe 7 | Statusbyte | 2 Bytes | CRT | |
| 115 | Ausgang A - Gruppe 7 | Schalten | 1 Bit | 1.1 switch | CW |
| 116 | Ausgang A - Gruppe 7 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 117 | Ausgang A - Gruppe 7 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 118 | Ausgang A - Gruppe 7 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 119 | Ausgang A - Gruppe 7 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 120 | Ausgang A - Gruppe 7 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 121 | Ausgang A - Gruppe 7 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 121 | Ausgang A - Gruppe 7 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 121 | Ausgang A - Gruppe 7 | Sperren | 1 Bit | 1.3 enable | CRW |
| 122 | Ausgang A - Gruppe 7 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 122 | Ausgang A - Gruppe 7 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 123 | Ausgang A - Gruppe 7 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 123 | Ausgang A - Gruppe 7 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 123 | Ausgang A - Gruppe 7 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 123 | Ausgang A - Gruppe 7 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 124 | Ausgang A - Gruppe 7 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 125 | Ausgang A - Gruppe 8 | Statusbyte | 2 Bytes | CRT | |
| 126 | Ausgang A - Gruppe 8 | Schalten | 1 Bit | 1.1 switch | CW |
| 127 | Ausgang A - Gruppe 8 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 128 | Ausgang A - Gruppe 8 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 129 | Ausgang A - Gruppe 8 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 130 | Ausgang A - Gruppe 8 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 131 | Ausgang A - Gruppe 8 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 132 | Ausgang A - Gruppe 8 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 132 | Ausgang A - Gruppe 8 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 132 | Ausgang A - Gruppe 8 | Sperren | 1 Bit | 1.3 enable | CRW |
| 133 | Ausgang A - Gruppe 8 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 133 | Ausgang A - Gruppe 8 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 134 | Ausgang A - Gruppe 8 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 134 | Ausgang A - Gruppe 8 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 134 | Ausgang A - Gruppe 8 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 134 | Ausgang A - Gruppe 8 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 135 | Ausgang A - Gruppe 8 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 136 | Ausgang A - Gruppe 9 | Statusbyte | 2 Bytes | CRT | |
| 137 | Ausgang A - Gruppe 9 | Schalten | 1 Bit | 1.1 switch | CW |
| 138 | Ausgang A - Gruppe 9 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 139 | Ausgang A - Gruppe 9 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 140 | Ausgang A - Gruppe 9 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 141 | Ausgang A - Gruppe 9 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 142 | Ausgang A - Gruppe 9 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 143 | Ausgang A - Gruppe 9 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 143 | Ausgang A - Gruppe 9 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 143 | Ausgang A - Gruppe 9 | Sperren | 1 Bit | 1.3 enable | CRW |
| 144 | Ausgang A - Gruppe 9 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 144 | Ausgang A - Gruppe 9 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 145 | Ausgang A - Gruppe 9 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 145 | Ausgang A - Gruppe 9 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 145 | Ausgang A - Gruppe 9 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 145 | Ausgang A - Gruppe 9 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 146 | Ausgang A - Gruppe 9 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 147 | Ausgang A - Gruppe 10 | Statusbyte | 2 Bytes | CRT | |
| 148 | Ausgang A - Gruppe 10 | Schalten | 1 Bit | 1.1 switch | CW |
| 149 | Ausgang A - Gruppe 10 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 150 | Ausgang A - Gruppe 10 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 151 | Ausgang A - Gruppe 10 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 152 | Ausgang A - Gruppe 10 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 153 | Ausgang A - Gruppe 10 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 154 | Ausgang A - Gruppe 10 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 154 | Ausgang A - Gruppe 10 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 154 | Ausgang A - Gruppe 10 | Sperren | 1 Bit | 1.3 enable | CRW |
| 155 | Ausgang A - Gruppe 10 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 155 | Ausgang A - Gruppe 10 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 156 | Ausgang A - Gruppe 10 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 156 | Ausgang A - Gruppe 10 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 156 | Ausgang A - Gruppe 10 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 156 | Ausgang A - Gruppe 10 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 157 | Ausgang A - Gruppe 10 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 158 | Ausgang A - Gruppe 11 | Statusbyte | 2 Bytes | CRT | |
| 159 | Ausgang A - Gruppe 11 | Schalten | 1 Bit | 1.1 switch | CW |
| 160 | Ausgang A - Gruppe 11 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 161 | Ausgang A - Gruppe 11 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 162 | Ausgang A - Gruppe 11 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 163 | Ausgang A - Gruppe 11 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 164 | Ausgang A - Gruppe 11 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 165 | Ausgang A - Gruppe 11 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 165 | Ausgang A - Gruppe 11 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 165 | Ausgang A - Gruppe 11 | Sperren | 1 Bit | 1.3 enable | CRW |
| 166 | Ausgang A - Gruppe 11 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 166 | Ausgang A - Gruppe 11 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 167 | Ausgang A - Gruppe 11 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 167 | Ausgang A - Gruppe 11 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 167 | Ausgang A - Gruppe 11 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 167 | Ausgang A - Gruppe 11 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 168 | Ausgang A - Gruppe 11 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 169 | Ausgang A - Gruppe 12 | Statusbyte | 2 Bytes | CRT | |
| 170 | Ausgang A - Gruppe 12 | Schalten | 1 Bit | 1.1 switch | CW |
| 171 | Ausgang A - Gruppe 12 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 172 | Ausgang A - Gruppe 12 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 173 | Ausgang A - Gruppe 12 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 174 | Ausgang A - Gruppe 12 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 175 | Ausgang A - Gruppe 12 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 176 | Ausgang A - Gruppe 12 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 176 | Ausgang A - Gruppe 12 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 176 | Ausgang A - Gruppe 12 | Sperren | 1 Bit | 1.3 enable | CRW |
| 177 | Ausgang A - Gruppe 12 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 177 | Ausgang A - Gruppe 12 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 178 | Ausgang A - Gruppe 12 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 178 | Ausgang A - Gruppe 12 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 178 | Ausgang A - Gruppe 12 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 178 | Ausgang A - Gruppe 12 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 179 | Ausgang A - Gruppe 12 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 180 | Ausgang A - Gruppe 13 | Statusbyte | 2 Bytes | CRT | |
| 181 | Ausgang A - Gruppe 13 | Schalten | 1 Bit | 1.1 switch | CW |
| 182 | Ausgang A - Gruppe 13 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 183 | Ausgang A - Gruppe 13 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 184 | Ausgang A - Gruppe 13 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 185 | Ausgang A - Gruppe 13 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 186 | Ausgang A - Gruppe 13 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 187 | Ausgang A - Gruppe 13 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 187 | Ausgang A - Gruppe 13 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 187 | Ausgang A - Gruppe 13 | Sperren | 1 Bit | 1.3 enable | CRW |
| 188 | Ausgang A - Gruppe 13 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 188 | Ausgang A - Gruppe 13 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 189 | Ausgang A - Gruppe 13 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 189 | Ausgang A - Gruppe 13 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 189 | Ausgang A - Gruppe 13 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 189 | Ausgang A - Gruppe 13 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 190 | Ausgang A - Gruppe 13 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 191 | Ausgang A - Gruppe 14 | Statusbyte | 2 Bytes | CRT | |
| 192 | Ausgang A - Gruppe 14 | Schalten | 1 Bit | 1.1 switch | CW |
| 193 | Ausgang A - Gruppe 14 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 194 | Ausgang A - Gruppe 14 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 195 | Ausgang A - Gruppe 14 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 196 | Ausgang A - Gruppe 14 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 197 | Ausgang A - Gruppe 14 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 198 | Ausgang A - Gruppe 14 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 198 | Ausgang A - Gruppe 14 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 198 | Ausgang A - Gruppe 14 | Sperren | 1 Bit | 1.3 enable | CRW |
| 199 | Ausgang A - Gruppe 14 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 199 | Ausgang A - Gruppe 14 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 200 | Ausgang A - Gruppe 14 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 200 | Ausgang A - Gruppe 14 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 200 | Ausgang A - Gruppe 14 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 200 | Ausgang A - Gruppe 14 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 201 | Ausgang A - Gruppe 14 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 202 | Ausgang A - Gruppe 15 | Statusbyte | 2 Bytes | CRT | |
| 203 | Ausgang A - Gruppe 15 | Schalten | 1 Bit | 1.1 switch | CW |
| 204 | Ausgang A - Gruppe 15 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 205 | Ausgang A - Gruppe 15 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 206 | Ausgang A - Gruppe 15 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 207 | Ausgang A - Gruppe 15 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 208 | Ausgang A - Gruppe 15 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 209 | Ausgang A - Gruppe 15 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 209 | Ausgang A - Gruppe 15 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 209 | Ausgang A - Gruppe 15 | Sperren | 1 Bit | 1.3 enable | CRW |
| 210 | Ausgang A - Gruppe 15 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 210 | Ausgang A - Gruppe 15 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 211 | Ausgang A - Gruppe 15 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 211 | Ausgang A - Gruppe 15 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 211 | Ausgang A - Gruppe 15 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 211 | Ausgang A - Gruppe 15 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 212 | Ausgang A - Gruppe 15 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 213 | Ausgang A - Gruppe 16 | Statusbyte | 2 Bytes | CRT | |
| 214 | Ausgang A - Gruppe 16 | Schalten | 1 Bit | 1.1 switch | CW |
| 215 | Ausgang A - Gruppe 16 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 216 | Ausgang A - Gruppe 16 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 217 | Ausgang A - Gruppe 16 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 218 | Ausgang A - Gruppe 16 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 219 | Ausgang A - Gruppe 16 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 220 | Ausgang A - Gruppe 16 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 220 | Ausgang A - Gruppe 16 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 220 | Ausgang A - Gruppe 16 | Sperren | 1 Bit | 1.3 enable | CRW |
| 221 | Ausgang A - Gruppe 16 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 221 | Ausgang A - Gruppe 16 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 222 | Ausgang A - Gruppe 16 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 222 | Ausgang A - Gruppe 16 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 222 | Ausgang A - Gruppe 16 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 222 | Ausgang A - Gruppe 16 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 223 | Ausgang A - Gruppe 16 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 224 | Ausgang A - EVG 1 | Statusbyte | 2 Bytes | CRT | |
| 225 | Ausgang A - EVG 1 | Schalten | 1 Bit | 1.1 switch | CW |
| 226 | Ausgang A - EVG 1 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 227 | Ausgang A - EVG 1 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 228 | Ausgang A - EVG 1 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 229 | Ausgang A - EVG 1 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 230 | Ausgang A - EVG 1 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 231 | Ausgang A - EVG 1 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 231 | Ausgang A - EVG 1 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 231 | Ausgang A - EVG 1 | Sperren | 1 Bit | 1.3 enable | CRW |
| 232 | Ausgang A - EVG 1 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 232 | Ausgang A - EVG 1 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 233 | Ausgang A - EVG 1 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 233 | Ausgang A - EVG 1 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 233 | Ausgang A - EVG 1 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 233 | Ausgang A - EVG 1 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 234 | Ausgang A - EVG 1 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 235 | Ausgang A - EVG 2 | Statusbyte | 2 Bytes | CRT | |
| 236 | Ausgang A - EVG 2 | Schalten | 1 Bit | 1.1 switch | CW |
| 237 | Ausgang A - EVG 2 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 238 | Ausgang A - EVG 2 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 239 | Ausgang A - EVG 2 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 240 | Ausgang A - EVG 2 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 241 | Ausgang A - EVG 2 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 242 | Ausgang A - EVG 2 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 242 | Ausgang A - EVG 2 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 242 | Ausgang A - EVG 2 | Sperren | 1 Bit | 1.3 enable | CRW |
| 243 | Ausgang A - EVG 2 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 243 | Ausgang A - EVG 2 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 244 | Ausgang A - EVG 2 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 244 | Ausgang A - EVG 2 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 244 | Ausgang A - EVG 2 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 244 | Ausgang A - EVG 2 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 245 | Ausgang A - EVG 2 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 246 | Ausgang A - EVG 3 | Statusbyte | 2 Bytes | CRT | |
| 247 | Ausgang A - EVG 3 | Schalten | 1 Bit | 1.1 switch | CW |
| 248 | Ausgang A - EVG 3 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 249 | Ausgang A - EVG 3 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 250 | Ausgang A - EVG 3 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 251 | Ausgang A - EVG 3 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 252 | Ausgang A - EVG 3 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 253 | Ausgang A - EVG 3 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 253 | Ausgang A - EVG 3 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 253 | Ausgang A - EVG 3 | Sperren | 1 Bit | 1.3 enable | CRW |
| 254 | Ausgang A - EVG 3 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 254 | Ausgang A - EVG 3 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 255 | Ausgang A - EVG 3 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 255 | Ausgang A - EVG 3 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 255 | Ausgang A - EVG 3 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 255 | Ausgang A - EVG 3 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 256 | Ausgang A - EVG 3 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 257 | Ausgang A - EVG 4 | Statusbyte | 2 Bytes | CRT | |
| 258 | Ausgang A - EVG 4 | Schalten | 1 Bit | 1.1 switch | CW |
| 259 | Ausgang A - EVG 4 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 260 | Ausgang A - EVG 4 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 261 | Ausgang A - EVG 4 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 262 | Ausgang A - EVG 4 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 263 | Ausgang A - EVG 4 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 264 | Ausgang A - EVG 4 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 264 | Ausgang A - EVG 4 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 264 | Ausgang A - EVG 4 | Sperren | 1 Bit | 1.3 enable | CRW |
| 265 | Ausgang A - EVG 4 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 265 | Ausgang A - EVG 4 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 266 | Ausgang A - EVG 4 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 266 | Ausgang A - EVG 4 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 266 | Ausgang A - EVG 4 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 266 | Ausgang A - EVG 4 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 267 | Ausgang A - EVG 4 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 268 | Ausgang A - EVG 5 | Statusbyte | 2 Bytes | CRT | |
| 269 | Ausgang A - EVG 5 | Schalten | 1 Bit | 1.1 switch | CW |
| 270 | Ausgang A - EVG 5 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 271 | Ausgang A - EVG 5 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 272 | Ausgang A - EVG 5 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 273 | Ausgang A - EVG 5 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 274 | Ausgang A - EVG 5 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 275 | Ausgang A - EVG 5 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 275 | Ausgang A - EVG 5 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 275 | Ausgang A - EVG 5 | Sperren | 1 Bit | 1.3 enable | CRW |
| 276 | Ausgang A - EVG 5 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 276 | Ausgang A - EVG 5 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 277 | Ausgang A - EVG 5 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 277 | Ausgang A - EVG 5 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 277 | Ausgang A - EVG 5 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 277 | Ausgang A - EVG 5 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 278 | Ausgang A - EVG 5 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 279 | Ausgang A - EVG 6 | Statusbyte | 2 Bytes | CRT | |
| 280 | Ausgang A - EVG 6 | Schalten | 1 Bit | 1.1 switch | CW |
| 281 | Ausgang A - EVG 6 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 282 | Ausgang A - EVG 6 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 283 | Ausgang A - EVG 6 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 284 | Ausgang A - EVG 6 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 285 | Ausgang A - EVG 6 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 286 | Ausgang A - EVG 6 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 286 | Ausgang A - EVG 6 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 286 | Ausgang A - EVG 6 | Sperren | 1 Bit | 1.3 enable | CRW |
| 287 | Ausgang A - EVG 6 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 287 | Ausgang A - EVG 6 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 288 | Ausgang A - EVG 6 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 288 | Ausgang A - EVG 6 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 288 | Ausgang A - EVG 6 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 288 | Ausgang A - EVG 6 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 289 | Ausgang A - EVG 6 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 290 | Ausgang A - EVG 7 | Statusbyte | 2 Bytes | CRT | |
| 291 | Ausgang A - EVG 7 | Schalten | 1 Bit | 1.1 switch | CW |
| 292 | Ausgang A - EVG 7 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 293 | Ausgang A - EVG 7 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 294 | Ausgang A - EVG 7 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 295 | Ausgang A - EVG 7 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 296 | Ausgang A - EVG 7 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 297 | Ausgang A - EVG 7 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 297 | Ausgang A - EVG 7 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 297 | Ausgang A - EVG 7 | Sperren | 1 Bit | 1.3 enable | CRW |
| 298 | Ausgang A - EVG 7 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 298 | Ausgang A - EVG 7 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 299 | Ausgang A - EVG 7 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 299 | Ausgang A - EVG 7 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 299 | Ausgang A - EVG 7 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 299 | Ausgang A - EVG 7 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 300 | Ausgang A - EVG 7 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 301 | Ausgang A - EVG 8 | Statusbyte | 2 Bytes | CRT | |
| 302 | Ausgang A - EVG 8 | Schalten | 1 Bit | 1.1 switch | CW |
| 303 | Ausgang A - EVG 8 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 304 | Ausgang A - EVG 8 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 305 | Ausgang A - EVG 8 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 306 | Ausgang A - EVG 8 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 307 | Ausgang A - EVG 8 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 308 | Ausgang A - EVG 8 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 308 | Ausgang A - EVG 8 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 308 | Ausgang A - EVG 8 | Sperren | 1 Bit | 1.3 enable | CRW |
| 309 | Ausgang A - EVG 8 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 309 | Ausgang A - EVG 8 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 310 | Ausgang A - EVG 8 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 310 | Ausgang A - EVG 8 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 310 | Ausgang A - EVG 8 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 310 | Ausgang A - EVG 8 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 311 | Ausgang A - EVG 8 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 312 | Ausgang A - EVG 9 | Statusbyte | 2 Bytes | CRT | |
| 313 | Ausgang A - EVG 9 | Schalten | 1 Bit | 1.1 switch | CW |
| 314 | Ausgang A - EVG 9 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 315 | Ausgang A - EVG 9 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 316 | Ausgang A - EVG 9 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 317 | Ausgang A - EVG 9 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 318 | Ausgang A - EVG 9 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 319 | Ausgang A - EVG 9 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 319 | Ausgang A - EVG 9 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 319 | Ausgang A - EVG 9 | Sperren | 1 Bit | 1.3 enable | CRW |
| 320 | Ausgang A - EVG 9 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 320 | Ausgang A - EVG 9 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 321 | Ausgang A - EVG 9 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 321 | Ausgang A - EVG 9 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 321 | Ausgang A - EVG 9 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 321 | Ausgang A - EVG 9 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 322 | Ausgang A - EVG 9 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 323 | Ausgang A - EVG 10 | Statusbyte | 2 Bytes | CRT | |
| 324 | Ausgang A - EVG 10 | Schalten | 1 Bit | 1.1 switch | CW |
| 325 | Ausgang A - EVG 10 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 326 | Ausgang A - EVG 10 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 327 | Ausgang A - EVG 10 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 328 | Ausgang A - EVG 10 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 329 | Ausgang A - EVG 10 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 330 | Ausgang A - EVG 10 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 330 | Ausgang A - EVG 10 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 330 | Ausgang A - EVG 10 | Sperren | 1 Bit | 1.3 enable | CRW |
| 331 | Ausgang A - EVG 10 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 331 | Ausgang A - EVG 10 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 332 | Ausgang A - EVG 10 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 332 | Ausgang A - EVG 10 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 332 | Ausgang A - EVG 10 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 332 | Ausgang A - EVG 10 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 333 | Ausgang A - EVG 10 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 334 | Ausgang A - EVG 11 | Statusbyte | 2 Bytes | CRT | |
| 335 | Ausgang A - EVG 11 | Schalten | 1 Bit | 1.1 switch | CW |
| 336 | Ausgang A - EVG 11 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 337 | Ausgang A - EVG 11 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 338 | Ausgang A - EVG 11 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 339 | Ausgang A - EVG 11 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 340 | Ausgang A - EVG 11 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 341 | Ausgang A - EVG 11 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 341 | Ausgang A - EVG 11 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 341 | Ausgang A - EVG 11 | Sperren | 1 Bit | 1.3 enable | CRW |
| 342 | Ausgang A - EVG 11 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 342 | Ausgang A - EVG 11 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 343 | Ausgang A - EVG 11 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 343 | Ausgang A - EVG 11 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 343 | Ausgang A - EVG 11 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 343 | Ausgang A - EVG 11 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 344 | Ausgang A - EVG 11 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 345 | Ausgang A - EVG 12 | Statusbyte | 2 Bytes | CRT | |
| 346 | Ausgang A - EVG 12 | Schalten | 1 Bit | 1.1 switch | CW |
| 347 | Ausgang A - EVG 12 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 348 | Ausgang A - EVG 12 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 349 | Ausgang A - EVG 12 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 350 | Ausgang A - EVG 12 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 351 | Ausgang A - EVG 12 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 352 | Ausgang A - EVG 12 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 352 | Ausgang A - EVG 12 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 352 | Ausgang A - EVG 12 | Sperren | 1 Bit | 1.3 enable | CRW |
| 353 | Ausgang A - EVG 12 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 353 | Ausgang A - EVG 12 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 354 | Ausgang A - EVG 12 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 354 | Ausgang A - EVG 12 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 354 | Ausgang A - EVG 12 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 354 | Ausgang A - EVG 12 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 355 | Ausgang A - EVG 12 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 356 | Ausgang A - EVG 13 | Statusbyte | 2 Bytes | CRT | |
| 357 | Ausgang A - EVG 13 | Schalten | 1 Bit | 1.1 switch | CW |
| 358 | Ausgang A - EVG 13 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 359 | Ausgang A - EVG 13 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 360 | Ausgang A - EVG 13 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 361 | Ausgang A - EVG 13 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 362 | Ausgang A - EVG 13 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 363 | Ausgang A - EVG 13 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 363 | Ausgang A - EVG 13 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 363 | Ausgang A - EVG 13 | Sperren | 1 Bit | 1.3 enable | CRW |
| 364 | Ausgang A - EVG 13 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 364 | Ausgang A - EVG 13 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 365 | Ausgang A - EVG 13 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 365 | Ausgang A - EVG 13 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 365 | Ausgang A - EVG 13 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 365 | Ausgang A - EVG 13 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 366 | Ausgang A - EVG 13 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 367 | Ausgang A - EVG 14 | Statusbyte | 2 Bytes | CRT | |
| 368 | Ausgang A - EVG 14 | Schalten | 1 Bit | 1.1 switch | CW |
| 369 | Ausgang A - EVG 14 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 370 | Ausgang A - EVG 14 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 371 | Ausgang A - EVG 14 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 372 | Ausgang A - EVG 14 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 373 | Ausgang A - EVG 14 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 374 | Ausgang A - EVG 14 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 374 | Ausgang A - EVG 14 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 374 | Ausgang A - EVG 14 | Sperren | 1 Bit | 1.3 enable | CRW |
| 375 | Ausgang A - EVG 14 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 375 | Ausgang A - EVG 14 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 376 | Ausgang A - EVG 14 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 376 | Ausgang A - EVG 14 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 376 | Ausgang A - EVG 14 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 376 | Ausgang A - EVG 14 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 377 | Ausgang A - EVG 14 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 378 | Ausgang A - EVG 15 | Statusbyte | 2 Bytes | CRT | |
| 379 | Ausgang A - EVG 15 | Schalten | 1 Bit | 1.1 switch | CW |
| 380 | Ausgang A - EVG 15 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 381 | Ausgang A - EVG 15 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 382 | Ausgang A - EVG 15 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 383 | Ausgang A - EVG 15 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 384 | Ausgang A - EVG 15 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 385 | Ausgang A - EVG 15 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 385 | Ausgang A - EVG 15 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 385 | Ausgang A - EVG 15 | Sperren | 1 Bit | 1.3 enable | CRW |
| 386 | Ausgang A - EVG 15 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 386 | Ausgang A - EVG 15 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 387 | Ausgang A - EVG 15 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 387 | Ausgang A - EVG 15 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 387 | Ausgang A - EVG 15 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 387 | Ausgang A - EVG 15 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 388 | Ausgang A - EVG 15 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 389 | Ausgang A - EVG 16 | Statusbyte | 2 Bytes | CRT | |
| 390 | Ausgang A - EVG 16 | Schalten | 1 Bit | 1.1 switch | CW |
| 391 | Ausgang A - EVG 16 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 392 | Ausgang A - EVG 16 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 393 | Ausgang A - EVG 16 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 394 | Ausgang A - EVG 16 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 395 | Ausgang A - EVG 16 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 396 | Ausgang A - EVG 16 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 396 | Ausgang A - EVG 16 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 396 | Ausgang A - EVG 16 | Sperren | 1 Bit | 1.3 enable | CRW |
| 397 | Ausgang A - EVG 16 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 397 | Ausgang A - EVG 16 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 398 | Ausgang A - EVG 16 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 398 | Ausgang A - EVG 16 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 398 | Ausgang A - EVG 16 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 398 | Ausgang A - EVG 16 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 399 | Ausgang A - EVG 16 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 400 | Ausgang A - EVG 17 | Statusbyte | 2 Bytes | CRT | |
| 401 | Ausgang A - EVG 17 | Schalten | 1 Bit | 1.1 switch | CW |
| 402 | Ausgang A - EVG 17 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 403 | Ausgang A - EVG 17 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 404 | Ausgang A - EVG 17 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 405 | Ausgang A - EVG 17 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 406 | Ausgang A - EVG 17 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 407 | Ausgang A - EVG 17 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 407 | Ausgang A - EVG 17 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 407 | Ausgang A - EVG 17 | Sperren | 1 Bit | 1.3 enable | CRW |
| 408 | Ausgang A - EVG 17 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 408 | Ausgang A - EVG 17 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 409 | Ausgang A - EVG 17 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 409 | Ausgang A - EVG 17 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 409 | Ausgang A - EVG 17 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 409 | Ausgang A - EVG 17 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 410 | Ausgang A - EVG 17 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 411 | Ausgang A - EVG 18 | Statusbyte | 2 Bytes | CRT | |
| 412 | Ausgang A - EVG 18 | Schalten | 1 Bit | 1.1 switch | CW |
| 413 | Ausgang A - EVG 18 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 414 | Ausgang A - EVG 18 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 415 | Ausgang A - EVG 18 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 416 | Ausgang A - EVG 18 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 417 | Ausgang A - EVG 18 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 418 | Ausgang A - EVG 18 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 418 | Ausgang A - EVG 18 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 418 | Ausgang A - EVG 18 | Sperren | 1 Bit | 1.3 enable | CRW |
| 419 | Ausgang A - EVG 18 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 419 | Ausgang A - EVG 18 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 420 | Ausgang A - EVG 18 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 420 | Ausgang A - EVG 18 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 420 | Ausgang A - EVG 18 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 420 | Ausgang A - EVG 18 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 421 | Ausgang A - EVG 18 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 422 | Ausgang A - EVG 19 | Statusbyte | 2 Bytes | CRT | |
| 423 | Ausgang A - EVG 19 | Schalten | 1 Bit | 1.1 switch | CW |
| 424 | Ausgang A - EVG 19 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 425 | Ausgang A - EVG 19 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 426 | Ausgang A - EVG 19 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 427 | Ausgang A - EVG 19 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 428 | Ausgang A - EVG 19 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 429 | Ausgang A - EVG 19 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 429 | Ausgang A - EVG 19 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 429 | Ausgang A - EVG 19 | Sperren | 1 Bit | 1.3 enable | CRW |
| 430 | Ausgang A - EVG 19 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 430 | Ausgang A - EVG 19 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 431 | Ausgang A - EVG 19 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 431 | Ausgang A - EVG 19 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 431 | Ausgang A - EVG 19 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 431 | Ausgang A - EVG 19 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 432 | Ausgang A - EVG 19 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 433 | Ausgang A - EVG 20 | Statusbyte | 2 Bytes | CRT | |
| 434 | Ausgang A - EVG 20 | Schalten | 1 Bit | 1.1 switch | CW |
| 435 | Ausgang A - EVG 20 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 436 | Ausgang A - EVG 20 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 437 | Ausgang A - EVG 20 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 438 | Ausgang A - EVG 20 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 439 | Ausgang A - EVG 20 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 440 | Ausgang A - EVG 20 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 440 | Ausgang A - EVG 20 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 440 | Ausgang A - EVG 20 | Sperren | 1 Bit | 1.3 enable | CRW |
| 441 | Ausgang A - EVG 20 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 441 | Ausgang A - EVG 20 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 442 | Ausgang A - EVG 20 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 442 | Ausgang A - EVG 20 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 442 | Ausgang A - EVG 20 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 442 | Ausgang A - EVG 20 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 443 | Ausgang A - EVG 20 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 444 | Ausgang A - EVG 21 | Statusbyte | 2 Bytes | CRT | |
| 445 | Ausgang A - EVG 21 | Schalten | 1 Bit | 1.1 switch | CW |
| 446 | Ausgang A - EVG 21 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 447 | Ausgang A - EVG 21 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 448 | Ausgang A - EVG 21 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 449 | Ausgang A - EVG 21 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 450 | Ausgang A - EVG 21 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 451 | Ausgang A - EVG 21 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 451 | Ausgang A - EVG 21 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 451 | Ausgang A - EVG 21 | Sperren | 1 Bit | 1.3 enable | CRW |
| 452 | Ausgang A - EVG 21 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 452 | Ausgang A - EVG 21 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 453 | Ausgang A - EVG 21 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 453 | Ausgang A - EVG 21 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 453 | Ausgang A - EVG 21 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 453 | Ausgang A - EVG 21 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 454 | Ausgang A - EVG 21 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 455 | Ausgang A - EVG 22 | Statusbyte | 2 Bytes | CRT | |
| 456 | Ausgang A - EVG 22 | Schalten | 1 Bit | 1.1 switch | CW |
| 457 | Ausgang A - EVG 22 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 458 | Ausgang A - EVG 22 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 459 | Ausgang A - EVG 22 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 460 | Ausgang A - EVG 22 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 461 | Ausgang A - EVG 22 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 462 | Ausgang A - EVG 22 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 462 | Ausgang A - EVG 22 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 462 | Ausgang A - EVG 22 | Sperren | 1 Bit | 1.3 enable | CRW |
| 463 | Ausgang A - EVG 22 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 463 | Ausgang A - EVG 22 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 464 | Ausgang A - EVG 22 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 464 | Ausgang A - EVG 22 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 464 | Ausgang A - EVG 22 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 464 | Ausgang A - EVG 22 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 465 | Ausgang A - EVG 22 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 466 | Ausgang A - EVG 23 | Statusbyte | 2 Bytes | CRT | |
| 467 | Ausgang A - EVG 23 | Schalten | 1 Bit | 1.1 switch | CW |
| 468 | Ausgang A - EVG 23 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 469 | Ausgang A - EVG 23 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 470 | Ausgang A - EVG 23 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 471 | Ausgang A - EVG 23 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 472 | Ausgang A - EVG 23 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 473 | Ausgang A - EVG 23 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 473 | Ausgang A - EVG 23 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 473 | Ausgang A - EVG 23 | Sperren | 1 Bit | 1.3 enable | CRW |
| 474 | Ausgang A - EVG 23 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 474 | Ausgang A - EVG 23 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 475 | Ausgang A - EVG 23 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 475 | Ausgang A - EVG 23 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 475 | Ausgang A - EVG 23 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 475 | Ausgang A - EVG 23 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 476 | Ausgang A - EVG 23 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 477 | Ausgang A - EVG 24 | Statusbyte | 2 Bytes | CRT | |
| 478 | Ausgang A - EVG 24 | Schalten | 1 Bit | 1.1 switch | CW |
| 479 | Ausgang A - EVG 24 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 480 | Ausgang A - EVG 24 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 481 | Ausgang A - EVG 24 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 482 | Ausgang A - EVG 24 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 483 | Ausgang A - EVG 24 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 484 | Ausgang A - EVG 24 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 484 | Ausgang A - EVG 24 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 484 | Ausgang A - EVG 24 | Sperren | 1 Bit | 1.3 enable | CRW |
| 485 | Ausgang A - EVG 24 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 485 | Ausgang A - EVG 24 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 486 | Ausgang A - EVG 24 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 486 | Ausgang A - EVG 24 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 486 | Ausgang A - EVG 24 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 486 | Ausgang A - EVG 24 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 487 | Ausgang A - EVG 24 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 488 | Ausgang A - EVG 25 | Statusbyte | 2 Bytes | CRT | |
| 489 | Ausgang A - EVG 25 | Schalten | 1 Bit | 1.1 switch | CW |
| 490 | Ausgang A - EVG 25 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 491 | Ausgang A - EVG 25 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 492 | Ausgang A - EVG 25 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 493 | Ausgang A - EVG 25 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 494 | Ausgang A - EVG 25 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 495 | Ausgang A - EVG 25 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 495 | Ausgang A - EVG 25 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 495 | Ausgang A - EVG 25 | Sperren | 1 Bit | 1.3 enable | CRW |
| 496 | Ausgang A - EVG 25 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 496 | Ausgang A - EVG 25 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 497 | Ausgang A - EVG 25 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 497 | Ausgang A - EVG 25 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 497 | Ausgang A - EVG 25 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 497 | Ausgang A - EVG 25 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 498 | Ausgang A - EVG 25 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 499 | Ausgang A - EVG 26 | Statusbyte | 2 Bytes | CRT | |
| 500 | Ausgang A - EVG 26 | Schalten | 1 Bit | 1.1 switch | CW |
| 501 | Ausgang A - EVG 26 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 502 | Ausgang A - EVG 26 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 503 | Ausgang A - EVG 26 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 504 | Ausgang A - EVG 26 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 505 | Ausgang A - EVG 26 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 506 | Ausgang A - EVG 26 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 506 | Ausgang A - EVG 26 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 506 | Ausgang A - EVG 26 | Sperren | 1 Bit | 1.3 enable | CRW |
| 507 | Ausgang A - EVG 26 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 507 | Ausgang A - EVG 26 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 508 | Ausgang A - EVG 26 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 508 | Ausgang A - EVG 26 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 508 | Ausgang A - EVG 26 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 508 | Ausgang A - EVG 26 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 509 | Ausgang A - EVG 26 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 510 | Ausgang A - EVG 27 | Statusbyte | 2 Bytes | CRT | |
| 511 | Ausgang A - EVG 27 | Schalten | 1 Bit | 1.1 switch | CW |
| 512 | Ausgang A - EVG 27 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 513 | Ausgang A - EVG 27 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 514 | Ausgang A - EVG 27 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 515 | Ausgang A - EVG 27 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 516 | Ausgang A - EVG 27 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 517 | Ausgang A - EVG 27 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 517 | Ausgang A - EVG 27 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 517 | Ausgang A - EVG 27 | Sperren | 1 Bit | 1.3 enable | CRW |
| 518 | Ausgang A - EVG 27 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 518 | Ausgang A - EVG 27 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 519 | Ausgang A - EVG 27 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 519 | Ausgang A - EVG 27 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 519 | Ausgang A - EVG 27 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 519 | Ausgang A - EVG 27 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 520 | Ausgang A - EVG 27 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 521 | Ausgang A - EVG 28 | Statusbyte | 2 Bytes | CRT | |
| 522 | Ausgang A - EVG 28 | Schalten | 1 Bit | 1.1 switch | CW |
| 523 | Ausgang A - EVG 28 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 524 | Ausgang A - EVG 28 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 525 | Ausgang A - EVG 28 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 526 | Ausgang A - EVG 28 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 527 | Ausgang A - EVG 28 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 528 | Ausgang A - EVG 28 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 528 | Ausgang A - EVG 28 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 528 | Ausgang A - EVG 28 | Sperren | 1 Bit | 1.3 enable | CRW |
| 529 | Ausgang A - EVG 28 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 529 | Ausgang A - EVG 28 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 530 | Ausgang A - EVG 28 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 530 | Ausgang A - EVG 28 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 530 | Ausgang A - EVG 28 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 530 | Ausgang A - EVG 28 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 531 | Ausgang A - EVG 28 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 532 | Ausgang A - EVG 29 | Statusbyte | 2 Bytes | CRT | |
| 533 | Ausgang A - EVG 29 | Schalten | 1 Bit | 1.1 switch | CW |
| 534 | Ausgang A - EVG 29 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 535 | Ausgang A - EVG 29 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 536 | Ausgang A - EVG 29 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 537 | Ausgang A - EVG 29 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 538 | Ausgang A - EVG 29 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 539 | Ausgang A - EVG 29 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 539 | Ausgang A - EVG 29 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 539 | Ausgang A - EVG 29 | Sperren | 1 Bit | 1.3 enable | CRW |
| 540 | Ausgang A - EVG 29 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 540 | Ausgang A - EVG 29 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 541 | Ausgang A - EVG 29 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 541 | Ausgang A - EVG 29 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 541 | Ausgang A - EVG 29 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 541 | Ausgang A - EVG 29 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 542 | Ausgang A - EVG 29 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 543 | Ausgang A - EVG 30 | Statusbyte | 2 Bytes | CRT | |
| 544 | Ausgang A - EVG 30 | Schalten | 1 Bit | 1.1 switch | CW |
| 545 | Ausgang A - EVG 30 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 546 | Ausgang A - EVG 30 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 547 | Ausgang A - EVG 30 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 548 | Ausgang A - EVG 30 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 549 | Ausgang A - EVG 30 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 550 | Ausgang A - EVG 30 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 550 | Ausgang A - EVG 30 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 550 | Ausgang A - EVG 30 | Sperren | 1 Bit | 1.3 enable | CRW |
| 551 | Ausgang A - EVG 30 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 551 | Ausgang A - EVG 30 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 552 | Ausgang A - EVG 30 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 552 | Ausgang A - EVG 30 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 552 | Ausgang A - EVG 30 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 552 | Ausgang A - EVG 30 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 553 | Ausgang A - EVG 30 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 554 | Ausgang A - EVG 31 | Statusbyte | 2 Bytes | CRT | |
| 555 | Ausgang A - EVG 31 | Schalten | 1 Bit | 1.1 switch | CW |
| 556 | Ausgang A - EVG 31 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 557 | Ausgang A - EVG 31 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 558 | Ausgang A - EVG 31 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 559 | Ausgang A - EVG 31 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 560 | Ausgang A - EVG 31 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 561 | Ausgang A - EVG 31 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 561 | Ausgang A - EVG 31 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 561 | Ausgang A - EVG 31 | Sperren | 1 Bit | 1.3 enable | CRW |
| 562 | Ausgang A - EVG 31 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 562 | Ausgang A - EVG 31 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 563 | Ausgang A - EVG 31 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 563 | Ausgang A - EVG 31 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 563 | Ausgang A - EVG 31 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 563 | Ausgang A - EVG 31 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 564 | Ausgang A - EVG 31 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 565 | Ausgang A - EVG 32 | Statusbyte | 2 Bytes | CRT | |
| 566 | Ausgang A - EVG 32 | Schalten | 1 Bit | 1.1 switch | CW |
| 567 | Ausgang A - EVG 32 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 568 | Ausgang A - EVG 32 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 569 | Ausgang A - EVG 32 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 570 | Ausgang A - EVG 32 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 571 | Ausgang A - EVG 32 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 572 | Ausgang A - EVG 32 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 572 | Ausgang A - EVG 32 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 572 | Ausgang A - EVG 32 | Sperren | 1 Bit | 1.3 enable | CRW |
| 573 | Ausgang A - EVG 32 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 573 | Ausgang A - EVG 32 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 574 | Ausgang A - EVG 32 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 574 | Ausgang A - EVG 32 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 574 | Ausgang A - EVG 32 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 574 | Ausgang A - EVG 32 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 575 | Ausgang A - EVG 32 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 576 | Ausgang A - EVG 33 | Statusbyte | 2 Bytes | CRT | |
| 577 | Ausgang A - EVG 33 | Schalten | 1 Bit | 1.1 switch | CW |
| 578 | Ausgang A - EVG 33 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 579 | Ausgang A - EVG 33 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 580 | Ausgang A - EVG 33 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 581 | Ausgang A - EVG 33 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 582 | Ausgang A - EVG 33 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 583 | Ausgang A - EVG 33 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 583 | Ausgang A - EVG 33 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 583 | Ausgang A - EVG 33 | Sperren | 1 Bit | 1.3 enable | CRW |
| 584 | Ausgang A - EVG 33 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 584 | Ausgang A - EVG 33 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 585 | Ausgang A - EVG 33 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 585 | Ausgang A - EVG 33 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 585 | Ausgang A - EVG 33 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 585 | Ausgang A - EVG 33 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 586 | Ausgang A - EVG 33 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 587 | Ausgang A - EVG 34 | Statusbyte | 2 Bytes | CRT | |
| 588 | Ausgang A - EVG 34 | Schalten | 1 Bit | 1.1 switch | CW |
| 589 | Ausgang A - EVG 34 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 590 | Ausgang A - EVG 34 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 591 | Ausgang A - EVG 34 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 592 | Ausgang A - EVG 34 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 593 | Ausgang A - EVG 34 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 594 | Ausgang A - EVG 34 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 594 | Ausgang A - EVG 34 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 594 | Ausgang A - EVG 34 | Sperren | 1 Bit | 1.3 enable | CRW |
| 595 | Ausgang A - EVG 34 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 595 | Ausgang A - EVG 34 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 596 | Ausgang A - EVG 34 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 596 | Ausgang A - EVG 34 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 596 | Ausgang A - EVG 34 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 596 | Ausgang A - EVG 34 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 597 | Ausgang A - EVG 34 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 598 | Ausgang A - EVG 35 | Statusbyte | 2 Bytes | CRT | |
| 599 | Ausgang A - EVG 35 | Schalten | 1 Bit | 1.1 switch | CW |
| 600 | Ausgang A - EVG 35 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 601 | Ausgang A - EVG 35 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 602 | Ausgang A - EVG 35 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 603 | Ausgang A - EVG 35 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 604 | Ausgang A - EVG 35 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 605 | Ausgang A - EVG 35 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 605 | Ausgang A - EVG 35 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 605 | Ausgang A - EVG 35 | Sperren | 1 Bit | 1.3 enable | CRW |
| 606 | Ausgang A - EVG 35 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 606 | Ausgang A - EVG 35 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 607 | Ausgang A - EVG 35 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 607 | Ausgang A - EVG 35 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 607 | Ausgang A - EVG 35 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 607 | Ausgang A - EVG 35 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 608 | Ausgang A - EVG 35 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 609 | Ausgang A - EVG 36 | Statusbyte | 2 Bytes | CRT | |
| 610 | Ausgang A - EVG 36 | Schalten | 1 Bit | 1.1 switch | CW |
| 611 | Ausgang A - EVG 36 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 612 | Ausgang A - EVG 36 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 613 | Ausgang A - EVG 36 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 614 | Ausgang A - EVG 36 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 615 | Ausgang A - EVG 36 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 616 | Ausgang A - EVG 36 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 616 | Ausgang A - EVG 36 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 616 | Ausgang A - EVG 36 | Sperren | 1 Bit | 1.3 enable | CRW |
| 617 | Ausgang A - EVG 36 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 617 | Ausgang A - EVG 36 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 618 | Ausgang A - EVG 36 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 618 | Ausgang A - EVG 36 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 618 | Ausgang A - EVG 36 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 618 | Ausgang A - EVG 36 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 619 | Ausgang A - EVG 36 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 620 | Ausgang A - EVG 37 | Statusbyte | 2 Bytes | CRT | |
| 621 | Ausgang A - EVG 37 | Schalten | 1 Bit | 1.1 switch | CW |
| 622 | Ausgang A - EVG 37 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 623 | Ausgang A - EVG 37 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 624 | Ausgang A - EVG 37 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 625 | Ausgang A - EVG 37 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 626 | Ausgang A - EVG 37 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 627 | Ausgang A - EVG 37 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 627 | Ausgang A - EVG 37 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 627 | Ausgang A - EVG 37 | Sperren | 1 Bit | 1.3 enable | CRW |
| 628 | Ausgang A - EVG 37 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 628 | Ausgang A - EVG 37 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 629 | Ausgang A - EVG 37 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 629 | Ausgang A - EVG 37 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 629 | Ausgang A - EVG 37 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 629 | Ausgang A - EVG 37 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 630 | Ausgang A - EVG 37 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 631 | Ausgang A - EVG 38 | Statusbyte | 2 Bytes | CRT | |
| 632 | Ausgang A - EVG 38 | Schalten | 1 Bit | 1.1 switch | CW |
| 633 | Ausgang A - EVG 38 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 634 | Ausgang A - EVG 38 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 635 | Ausgang A - EVG 38 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 636 | Ausgang A - EVG 38 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 637 | Ausgang A - EVG 38 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 638 | Ausgang A - EVG 38 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 638 | Ausgang A - EVG 38 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 638 | Ausgang A - EVG 38 | Sperren | 1 Bit | 1.3 enable | CRW |
| 639 | Ausgang A - EVG 38 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 639 | Ausgang A - EVG 38 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 640 | Ausgang A - EVG 38 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 640 | Ausgang A - EVG 38 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 640 | Ausgang A - EVG 38 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 640 | Ausgang A - EVG 38 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 641 | Ausgang A - EVG 38 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 642 | Ausgang A - EVG 39 | Statusbyte | 2 Bytes | CRT | |
| 643 | Ausgang A - EVG 39 | Schalten | 1 Bit | 1.1 switch | CW |
| 644 | Ausgang A - EVG 39 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 645 | Ausgang A - EVG 39 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 646 | Ausgang A - EVG 39 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 647 | Ausgang A - EVG 39 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 648 | Ausgang A - EVG 39 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 649 | Ausgang A - EVG 39 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 649 | Ausgang A - EVG 39 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 649 | Ausgang A - EVG 39 | Sperren | 1 Bit | 1.3 enable | CRW |
| 650 | Ausgang A - EVG 39 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 650 | Ausgang A - EVG 39 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 651 | Ausgang A - EVG 39 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 651 | Ausgang A - EVG 39 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 651 | Ausgang A - EVG 39 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 651 | Ausgang A - EVG 39 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 652 | Ausgang A - EVG 39 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 653 | Ausgang A - EVG 40 | Statusbyte | 2 Bytes | CRT | |
| 654 | Ausgang A - EVG 40 | Schalten | 1 Bit | 1.1 switch | CW |
| 655 | Ausgang A - EVG 40 | Status Schalten | 1 Bit | 1.1 switch | CRT |
| 656 | Ausgang A - EVG 40 | Relativ Dimmen | 4 Bit | 3.7 dimming control | CW |
| 657 | Ausgang A - EVG 40 | Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CW |
| 658 | Ausgang A - EVG 40 | Status Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 659 | Ausgang A - EVG 40 | Störung Lampe/EVG | 1 Bit | 1.5 alarm | CRT |
| 660 | Ausgang A - EVG 40 | Zwangsführung 2-Bit | 2 Bit | 2.1 switch control | CRW |
| 660 | Ausgang A - EVG 40 | Zwangsführung 1-Bit | 1 Bit | 1.3 enable | CRW |
| 660 | Ausgang A - EVG 40 | Sperren | 1 Bit | 1.3 enable | CRW |
| 661 | Ausgang A - EVG 40 | Lampe einbrennen | 1 Bit | 1.10 start/stop | CW |
| 661 | Ausgang A - EVG 40 | Lampe einbrennen/Status | 1 Bit | 1.10 start/stop | CRWT |
| 662 | Ausgang A - EVG 40 | Fkt. Treppenlicht aktivieren | 1 Bit | 1.10 start/stop | CW |
| 662 | Ausgang A - EVG 40 | Fkt. Treppenlicht aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 662 | Ausgang A - EVG 40 | Fkt. Slave aktivieren | 1 Bit | 1.10 start/stop | CW |
| 662 | Ausgang A - EVG 40 | Fkt. Slave aktivieren/Status | 1 Bit | 1.10 start/stop | CRWT |
| 663 | Ausgang A - EVG 40 | Slave Helligkeitswert | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 664 | Ausgang A - EVG 41 | Statusbyte | 2 Bytes | CRT | |
| 665 | Ausgang A - EVG 41 | Schalten | 1 Bit | 1.1 switch | CW |
First 1000 of 1726 group objects shown. Download the .knxprod for the full list.
Parameters (475)
| Parameter | Type | Default |
|---|---|---|
| Manuelle Bedienung freigeben Obj. "Man. Bed. Sperren/Status" | list | ja |
| Kommunikationsobjekt freigeben "In Betrieb" | list | nein |
| Anzahl KNX-Telegramme begrenzen | list | nein |
| Quittieren freigeben über Objekt "Störung Gateway-Betriebsspannung quittieren" | list | nein |
| Senden | list | Wert 1 |
| Anfordern bei Objektwert | list | 1 |
| Helligkeitswert nach Verlassen der manuellen Bedienung | list | Manuell eingestellter Helligkeitswert bleibt erhalten |
| Maximale Anzahl gesendeter Telegramme | unsignedInt 1…255 | 20 |
| Inaktive Wartezeit nach KNX Wiederkehr | unsignedInt 2…255 | 5 |
| Einschalten über Dimmen zulassen (Fkt. Relativ Dimmen Ausgang) | list | ja |
| Einschalten über Helligkeitswert zulassen (Fkt. Helligkeitswert Ausgang) | list | ja |
| Ausschalten auf Ausschalthelligkeit (Fkt. Schalten Ausgang) | list | nein |
| Ausschalten über Dimmen zulassen (Fkt. Relativ Dimmen Ausgang) | list | nein |
| Einschaltwert (Fkt. Schalten Ausgang) | list | 100% (255) |
| Ausschalthelligkeit | list | 30% (77) |
| Dimmzeit (0 = anspringen) | unsignedInt 0…65535 | 2 |
| Dimmzeit für Relativ Dimmen 0…100% (Fkt. Relativ Dimmen) | list | 5,7 |
| Objektwert senden | list | bei Änderung oder auf Anforderung |
| Kommunikationsobjekt freigeben "Status-Byte-Ausgang X" | list | ja |
| Kommunikationsobjekt freigeben "Status Schalten" | list | nein |
| Kommunikationsobjekt freigeben "Status Helligkeitswert" | list | nein |
| Kommunikationsobjekt freigeben "Status Schalten adressiert" | list | nein |
| Kommunikationsobjekt freigeben "Status Helligkeitswert adressiert" | list | nein |
| Wert bei unterschiedlichen Helligkeits- zuständen am DALI Ausgang | list | mittlere Helligkeit aller Leuchten am Ausgang |
| Wert bei unterschiedlichen Schalt- zuständen am DALI Ausgang | list | EIN |
| DALI Gruppen freigeben (Gruppen-Steuerung) | list | ja |
| DALI EVGs freigeben (Einzel-Steuerung) | list | nein |
| DALI Notlicht-Konverter freigeben (Notlicht-Steuerung) | list | nein |
| Gruppe 1 verwenden | list | ja |
| Gruppe 2 verwenden | list | ja |
| Gruppe 3 verwenden | list | ja |
| Gruppe 4 verwenden | list | ja |
| Gruppe 5 verwenden | list | ja |
| Gruppe 6 verwenden | list | ja |
| Gruppe 7 verwenden | list | ja |
| Gruppe 8 verwenden | list | ja |
| Gruppe 9 verwenden | list | ja |
| Gruppe 10 verwenden | list | ja |
| Gruppe 11 verwenden | list | ja |
| Gruppe 12 verwenden | list | ja |
| Gruppe 13 verwenden | list | ja |
| Gruppe 14 verwenden | list | ja |
| Gruppe 15 verwenden | list | ja |
| EVG 1 verwenden | list | nein |
| EVG 2 verwenden | list | nein |
| EVG 3 verwenden | list | nein |
| EVG 4 verwenden | list | nein |
| EVG 5 verwenden | list | nein |
| EVG 6 verwenden | list | nein |
| EVG 7 verwenden | list | nein |
| EVG 8 verwenden | list | nein |
| EVG 9 verwenden | list | nein |
| EVG 10 verwenden | list | nein |
| EVG 11 verwenden | list | nein |
| EVG 12 verwenden | list | nein |
| EVG 13 verwenden | list | nein |
| EVG 14 verwenden | list | nein |
| EVG 15 verwenden | list | nein |
| EVG 16 verwenden | list | nein |
| EVG 17 verwenden | list | nein |
| EVG 18 verwenden | list | nein |
| EVG 19 verwenden | list | nein |
| EVG 20 verwenden | list | nein |
| EVG 21 verwenden | list | nein |
| EVG 22 verwenden | list | nein |
| EVG 23 verwenden | list | nein |
| EVG 24 verwenden | list | nein |
| EVG 25 verwenden | list | nein |
| EVG 26 verwenden | list | nein |
| EVG 27 verwenden | list | nein |
| EVG 28 verwenden | list | nein |
| EVG 29 verwenden | list | nein |
| EVG 30 verwenden | list | nein |
| EVG 31 verwenden | list | nein |
| EVG 32 verwenden | list | nein |
| EVG 33 verwenden | list | nein |
| EVG 34 verwenden | list | nein |
| EVG 35 verwenden | list | nein |
| EVG 36 verwenden | list | nein |
| EVG 37 verwenden | list | nein |
| EVG 38 verwenden | list | nein |
| EVG 39 verwenden | list | nein |
| EVG 40 verwenden | list | nein |
| EVG 41 verwenden | list | nein |
| EVG 42 verwenden | list | nein |
| EVG 43 verwenden | list | nein |
| EVG 44 verwenden | list | nein |
| EVG 45 verwenden | list | nein |
| EVG 46 verwenden | list | nein |
| EVG 47 verwenden | list | nein |
| EVG 48 verwenden | list | nein |
| EVG 49 verwenden | list | nein |
| EVG 50 verwenden | list | nein |
| EVG 51 verwenden | list | nein |
| EVG 52 verwenden | list | nein |
| EVG 53 verwenden | list | nein |
| EVG 54 verwenden | list | nein |
| EVG 55 verwenden | list | nein |
| EVG 56 verwenden | list | nein |
| EVG 57 verwenden | list | nein |
| EVG 58 verwenden | list | nein |
| EVG 59 verwenden | list | nein |
| EVG 60 verwenden | list | nein |
| EVG 61 verwenden | list | nein |
| EVG 62 verwenden | list | nein |
| EVG 63 verwenden | list | nein |
| Notlicht-Konverter 1 verwenden | list | nein |
| Notlicht-Konverter 2 verwenden | list | nein |
| Notlicht-Konverter 3 verwenden | list | nein |
| Notlicht-Konverter 4 verwenden | list | nein |
| Notlicht-Konverter 5 verwenden | list | nein |
| Notlicht-Konverter 6 verwenden | list | nein |
| Notlicht-Konverter 7 verwenden | list | nein |
| Notlicht-Konverter 8 verwenden | list | nein |
| Notlicht-Konverter 9 verwenden | list | nein |
| Notlicht-Konverter 10 verwenden | list | nein |
| Notlicht-Konverter 11 verwenden | list | nein |
| Notlicht-Konverter 12 verwenden | list | nein |
| Notlicht-Konverter 13 verwenden | list | nein |
| Notlicht-Konverter 14 verwenden | list | nein |
| Notlicht-Konverter 15 verwenden | list | nein |
| Notlicht-Konverter 16 verwenden | list | nein |
| Notlicht-Konverter 17 verwenden | list | nein |
| Notlicht-Konverter 18 verwenden | list | nein |
| Notlicht-Konverter 19 verwenden | list | nein |
| Notlicht-Konverter 20 verwenden | list | nein |
| Notlicht-Konverter 21 verwenden | list | nein |
| Notlicht-Konverter 22 verwenden | list | nein |
| Notlicht-Konverter 23 verwenden | list | nein |
| Notlicht-Konverter 24 verwenden | list | nein |
| Notlicht-Konverter 25 verwenden | list | nein |
| Notlicht-Konverter 26 verwenden | list | nein |
| Notlicht-Konverter 27 verwenden | list | nein |
| Notlicht-Konverter 28 verwenden | list | nein |
| Notlicht-Konverter 29 verwenden | list | nein |
| Notlicht-Konverter 30 verwenden | list | nein |
| Notlicht-Konverter 31 verwenden | list | nein |
| Notlicht-Konverter 32 verwenden | list | nein |
| Notlicht-Konverter 33 verwenden | list | nein |
| Notlicht-Konverter 34 verwenden | list | nein |
| Notlicht-Konverter 35 verwenden | list | nein |
| Notlicht-Konverter 36 verwenden | list | nein |
| Notlicht-Konverter 37 verwenden | list | nein |
| Notlicht-Konverter 38 verwenden | list | nein |
| Notlicht-Konverter 39 verwenden | list | nein |
| Notlicht-Konverter 40 verwenden | list | nein |
| Notlicht-Konverter 41 verwenden | list | nein |
| Notlicht-Konverter 42 verwenden | list | nein |
| Notlicht-Konverter 43 verwenden | list | nein |
| Notlicht-Konverter 44 verwenden | list | nein |
| Notlicht-Konverter 45 verwenden | list | nein |
| Notlicht-Konverter 46 verwenden | list | nein |
| Notlicht-Konverter 47 verwenden | list | nein |
| Notlicht-Konverter 48 verwenden | list | nein |
| Notlicht-Konverter 49 verwenden | list | nein |
| Notlicht-Konverter 50 verwenden | list | nein |
| Notlicht-Konverter 51 verwenden | list | nein |
| Notlicht-Konverter 52 verwenden | list | nein |
| Notlicht-Konverter 53 verwenden | list | nein |
| Notlicht-Konverter 54 verwenden | list | nein |
| Notlicht-Konverter 55 verwenden | list | nein |
| Notlicht-Konverter 56 verwenden | list | nein |
| Notlicht-Konverter 57 verwenden | list | nein |
| Notlicht-Konverter 58 verwenden | list | nein |
| Notlicht-Konverter 59 verwenden | list | nein |
| Notlicht-Konverter 60 verwenden | list | nein |
| Notlicht-Konverter 61 verwenden | list | nein |
| Notlicht-Konverter 62 verwenden | list | nein |
| Notlicht-Konverter 63 verwenden | list | nein |
| Kommunikationsobjekt freigeben "Störung DALI Spannung" | list | ja |
| Kommunikationsobjekt freigeben "Störung Lampe" | list | nein |
| Kommunikationsobjekt freigeben "Störung EVG" | list | nein |
| Kommunikationsobjekt freigeben "Störung adressiert" | list | nein |
| Kommunikationsobjekt freigeben "Störung Anzahl Statistik" | list | nein |
| Kommunikationsobjekt freigeben "Störung EVG Anzahl" | list | nein |
| Kommunikationsobjekte für zusätzliche Störmeldeanzeigen freigeben "Störung EVG Nummer" "Störung EVG weiterschalten" | list | nein |
| Kommunikationsobjekt freigeben "Störung Gruppen Anzahl" | list | nein |
| Störmeldungen quittieren Kommunikationsobjekt freigeben "Störmeldungen quittieren/Status" | list | nein |
| Kommunikationsobjekt freigeben "Fkt. Ausschalthelligkeit aktivieren" | list | nein |
| Kommunikationsobjekt freigeben "Rest-Einbrennzeit" | list | nein |
| Kommunikationsobjekt freigeben "Lampen einbrennen/Status" | list | nein |
| Kommunikationsobjekt freigeben "Betriebsstunden" | list | nein |
| Kommunikationsobjekt freigeben "Betriebsstunden setzen" | list | nein |
| Kommunikationsobjekt freigeben "Slave Offset aktivieren/Status" | list | nein |
| Funktion Slave Offset nach KNX Wiederkehr und Download | list | aktiviert |
| Funktion "Teilausfall" freigeben | list | nein |
| - Störung DALI Spannung | list | nein |
| - Aktiver Notlichtfall gemeldet durch Notlicht-Konverter | list | nein |
| Automatische Notlicht-Prüfungen zulassen (Notlicht-Konverter müssen dies unterstützen) | list | nein |
| Fkt. Automatische Notlicht-Prüfungen freigeben Objekt "Autom. Notlicht-Prüfungen synchronisieren" | list | nein |
| Funktion Inhibit/Rest-Mode freigeben Objekt "Inhibit/Rest-Mode aktivieren" | list | nein |
| Zeitversatz der Prüfungen von zwei aufeinander folgenden Notlicht-Konvertern | unsignedInt 0…255 | 1 |
| Einschalten über Dimmen zulassen (Fkt. Relativ Dimmen) | list | ja |
| Einschalten über Helligkeitswert zulassen (Fkt. Helligkeitswert) | list | ja |
| Ausschalten auf Ausschalthelligkeit (Fkt. Schalten) | list | nein |
| Ausschalten über Dimmen zulassen (Fkt. Relativ Dimmen) | list | nein |
| Auswahl Dimmkurve | list | DALI (logarithmisch) |
| Dimmzeit bis Einschaltwert erreicht | list | unveränderliche Dimmzeit |
| Dimmzeit bis Ausschaltwert erreicht | list | unveränderliche Dimmzeit |
| Dimmzeit bis Helligkeitswert erreicht (Fkt. Helligkeitswert) | list | unveränderliche Dimmzeit |
| Ausschalthelligkeit aktivieren über Kommunikationsobjekt "Fkt. Ausschalthelligkeit aktivieren" (freigeben unter "Ausgang Funktionen") | list | nein |
| Zusatzfunktion freigeben | list | keine |
| Einschaltwert (Fkt. Schalten) | list | 100% (255) |
| Minimaler Dimmwert | list | 1% (3) |
| Maximaler Dimmwert | list | 100% (255) |
| Parametereinstellungen | list | aus Vorlage übernehmen |
| Zwischenwerte senden bei Übergängen (z.B. Andimmen, Szenen-Übergang) | list | nein |
| Kommunikationsobjekt freigeben "Statusbyte" | list | ja |
| Sendeintervall | unsignedInt 0…65535 | 2 |
| Kommunikationsobjekt freigeben "Störung Lampe/EVG" | list | nein |
| Helligkeit bei KNX oder DALI Spannungsausfall (DALI System Failure Level) | list | keine Änderung |
| Inhalt des Kommunikationsobjekts | list | Störung Lampe oder EVG |
| Helligkeit nach KNX Spannungswiederkehr und Download | list | letzter Wert vor Ausfall |
| Helligkeit nach EVG Wiederkehr im laufenden Betrieb | list | aktueller KNX Sollzustand |
| Helligkeit bei EVG Spannungswiederkehr (DALI Power-On Level) | list | 100% (255) |
| Funktion Zwangsführung/Sperren freigeben | list | nein |
| Funktion Teilausfall berücksichtigen | list | nein |
| Einbrennzeit | unsignedInt 1…255 | 100 |
| Helligkeitswert während Teilausfall | list | 100% (255) |
| Im Zeitraum | list | 1 s |
| Nach inaktiver Wartezeit Statuswerte senden | list | nein |
| Sendezyklus | unsignedInt 1…65535 | 60 |
| Ausschalten über Helligkeitswert zulassen (Fkt. Helligkeitswert Ausgang) | list | ja |
| Gruppe 16 verwenden | list | ja |
| EVG 64 verwenden | list | nein |
| Notlicht-Konverter 64 verwenden | list | nein |
| "Notlicht-Prüfung starten (Adr.)" | list | nein |
| "Notlicht-Prüfung Status (Adr.)" | list | nein |
| "Notlicht-Prüfung Ergebnis (Adr.)" | list | nein |
| Gruppe 9 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 13 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 14 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 15 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 16 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 3 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 4 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 6 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 7 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 8 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 9 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 11 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 12 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 13 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 14 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 15 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 16 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 17 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 19 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 20 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 21 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 22 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 23 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 24 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 25 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 26 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 27 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 28 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 29 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 30 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 31 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 32 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 33 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 34 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 35 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Name (max. 40 Zeichen) | text | G1 |
| DALI Szenen freigeben (Szenen-Steuerung) | list | nein |
| Nachlaufzeit (Prolong Time) nach Ende des Notlichtbetriebs | unsignedInt 0…127 | 0 |
| Art der Prüfung | list | Dauerprüfung |
| Dauer für Teildauerprüfung autom. aus Bemessungsdauer ableiten | list | ja |
| An automatischer Dauer-/Teildauerprüfung teilnehmen | list | nein |
| An automatischer Funktionsprüfung teilnehmen | list | nein |
| "Notlicht-Konverter Status" | list | nein |
| "Notlicht-Prüfung Ergebnis" | list | nein |
| "Notlicht-Prüfung starten" | list | ja, KNX Format DPT_CTC |
| Notlicht-Konverter reagiert auf Objekt "Inhibit/Rest Mode" | list | nein |
| Helligkeitswert im Notbetrieb (muss vom Notlicht-Konverter unterstützt werden) | list | 100% (255) |
| Prüfzyklus | unsignedInt 1…97 | 52 |
| Jede wievielte Prüfung ist eine Dauerprüfung | unsignedInt 2…100 | 12 |
| Szenenübergangszeit | list | 2,0 s |
| gespeicherte Szenenwerte bei Download überschreiben | list | ja |
| Gruppe 1 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 2 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 3 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 4 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 5 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 6 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 7 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 8 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 10 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 11 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Gruppe 12 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 1 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 2 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 5 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 10 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 18 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 36 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 37 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 38 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 39 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 40 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 41 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 42 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 44 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 45 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 46 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 47 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 48 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 49 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 50 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 51 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 52 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 53 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 54 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 55 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 56 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 57 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 58 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 59 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 60 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 61 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 62 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 63 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 64 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| EVG 43 Szenenwert | list | keine Änderung (nicht Bestandteil dieser Szene) |
| Kommunikationsobjekt freigeben "Statuswerte anfordern" | list | nein |
| Kommunikationsobjekt freigeben "Störung Gateway-Betriebsspannung" | list | nein |
| Kommunikationsobjekt freigeben "Störmeldungen sperren/Status" | list | nein |
| extern über Objekt "Teilausfall aktivieren/Status" | list | nein |
| - Lampen/EVG-Störung | list | nein |
| "Alle Notlicht-Prüfungen stoppen" | list | nein |
| Statusmeldung des Einbrennvorganges | list | nein |
| Zeitdauer, in der Notlicht-Prüfung gestartet werden muss | unsignedInt 0…255 | 7 |
| Die Anzahl erkannter Lampen/EVG-Störungen muss größer oder gleich sein als | unsignedInt 1…64 | 1 |
| Die Anzahl erkannter Notlichtfälle muss größer oder gleich sein als | unsignedInt 1…64 | 1 |
| Prüfzyklus | unsignedInt 1…255 | 7 |
| Kommunikationsobjekte für zusätzliche Störmeldeanzeigen freigeben "Störung Gruppe Nummer" "Störung Gruppe weiterschalten" | list | nein |
| Dimmzeit bis Helligkeitswert erreicht (Fkt. Helligkeitswert Ausgang) | list | unveränderliche Dimmzeit |
| Ausschalten über Helligkeitswert zulassen (Fkt. Helligkeitswert) | list | ja |
| Helligkeitswert bei zwangsweise Einschalten | list | 100% (255) |
| Funktion Einbrennen freigeben Objekt "Lampen einbrennen" | list | nein |
| intern an DALI-Ausgang | list | ja |
| Treppenlicht verlängert sich bei mehrfachem Einschalten | list | nein |
| Basishelligkeit für Treppenlicht | list | 30% (77) |
| Statusmeldung senden über Objekt "Fkt. Slave aktivieren/Status" | list | nein |
| Offset zwischen Slave und Master | list | nein |
| Dimmzeit bis Slave Helligkeitswert erreicht | list | unveränderliche Dimmzeit |
| Kommunikationsobjekt "Slave Offset aktivieren" auswerten | list | nein |
| Offset zwischen Slave und Master (Abweichung vom Masterwert in %) | signedInt -99…99 | -30 |
| Statusmeldung senden über Objekt "Fkt. Treppenlicht aktivieren/Status" | list | nein |
| Verhalten bei Aktivierung über Objekt "Fkt. Treppenlicht aktivieren" | list | aktiviert und EIN |
| Treppenlicht Ausschalten über Basishelligkeit (Vorwarnung) | list | nein |
| Helligkeitswert für Treppenlicht | list | 100% (255) |
| Dimmzeit bis Treppenlicht erreicht (0 = anspringen) | unsignedInt 0…65535 | 2 |
| Dimmzeit bis Ausschaltwert erreicht | unsignedInt 0…65535 | 2 |
| Dimmzeit bis Basishelligkeit erreicht | unsignedInt 0…65535 | 2 |
| Treppenlichtzeit | unsignedInt 0…65535 | 300 |
| Haltezeit Basishelligkeit (0 = unendlich) | unsignedInt 0…65535 | 10 |
| Verhalten nach KNX Spannungswiederkehr und Download | list | aktiviert und im Standby |
| ...Szenen-Aufruf | list | keine Reaktion |
| ...Relativ Dimmen | list | keine Reaktion |
| ...Helligkeitswert | list | keine Reaktion |
| ...Einschalten | list | keine Reaktion |
| Verhalten bei Aktivierung über Objekt "Fkt. Slave aktivieren" | list | aktiviert und EIN |
| Quelle (Slave wird gesteuert über) | list | Objekt "Slave Helligkeitswert" |
| Zeit für autom. Zurücksetzen | unsignedInt 2…255 | 60 |
| Zurücksetzen von manueller Bedienung auf KNX-Betrieb | list | über Taste und automatisch |
| Name (max. 40 Zeichen) | text | Kanal A |
| Automatische DALI Adressierung zulassen | list | nein |
| Pause zwischen zwei DALI QUERY Abfragen | unsignedInt 0…255 | 2 |
| Inhibit/Rest-Mode automatisch beenden nach | unsignedInt 0…48 | 8 |
| Statusmeldung Inhibit/Rest-Mode senden | list | nein |
| Zeitdauer für Teildauerprüfung | unsignedInt 1…600 | 35 |
| Ausschalthelligkeit beim Ausschalten berücksichtigen | list | nein |
| DALI Szene 1: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 2: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 3: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 4: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 5: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 6: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 7: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 8: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 9: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 10: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 11: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 12: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 13: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 14: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 15: KNX Szenennummer | list | Szene nicht verwendet |
| DALI Szene 16: KNX Szenennummer | list | Szene nicht verwendet |
| Convertible as of version 0.1 | unsignedInt 0…255 | 1 |
| Kommunikationsobjekt freigeben "Flexible Dimmzeit/Fade Time ..." | list | nein |
| Objektformat Dimmzeit/Fade Time | list | DALI Format [0...15] |
| Name (max. 40 Zeichen) | text | G2 |
| Name (max. 40 Zeichen) | text | G3 |
| Name (max. 40 Zeichen) | text | G4 |
| Name (max. 40 Zeichen) | text | G5 |
| Name (max. 40 Zeichen) | text | G6 |
| Name (max. 40 Zeichen) | text | G7 |
| Name (max. 40 Zeichen) | text | G8 |
| Name (max. 40 Zeichen) | text | G9 |
| Name (max. 40 Zeichen) | text | G10 |
| Name (max. 40 Zeichen) | text | G11 |
| Name (max. 40 Zeichen) | text | G12 |
| Name (max. 40 Zeichen) | text | G13 |
| Name (max. 40 Zeichen) | text | G14 |
| Name (max. 40 Zeichen) | text | G15 |
| Name (max. 40 Zeichen) | text | G16 |
| Zustand der Zwangsführung nach KNX Spannungswiederkehr | list | inaktiv |
| Zustand Sperren nach KNX Spannungswiederkehr | list | nicht gesperrt |
| Name (max. 40 Zeichen) | text | EVG1 |
| Name (max. 40 Zeichen) | text | EVG2 |
| Name (max. 40 Zeichen) | text | EVG3 |
| Name (max. 40 Zeichen) | text | EVG4 |
| Name (max. 40 Zeichen) | text | EVG5 |
| Name (max. 40 Zeichen) | text | EVG6 |
| Name (max. 40 Zeichen) | text | EVG7 |
| Name (max. 40 Zeichen) | text | EVG8 |
| Name (max. 40 Zeichen) | text | EVG9 |
| Name (max. 40 Zeichen) | text | EVG10 |
| Name (max. 40 Zeichen) | text | EVG11 |
| Name (max. 40 Zeichen) | text | EVG12 |
| Name (max. 40 Zeichen) | text | EVG13 |
| Name (max. 40 Zeichen) | text | EVG14 |
| Name (max. 40 Zeichen) | text | EVG15 |
| Name (max. 40 Zeichen) | text | EVG16 |
| Name (max. 40 Zeichen) | text | EVG17 |
| Name (max. 40 Zeichen) | text | EVG18 |
| Name (max. 40 Zeichen) | text | EVG19 |
| Name (max. 40 Zeichen) | text | EVG20 |
| Name (max. 40 Zeichen) | text | EVG21 |
| Name (max. 40 Zeichen) | text | EVG22 |
| Name (max. 40 Zeichen) | text | EVG23 |
| Name (max. 40 Zeichen) | text | EVG24 |
| Name (max. 40 Zeichen) | text | EVG25 |
| Name (max. 40 Zeichen) | text | EVG26 |
| Name (max. 40 Zeichen) | text | EVG27 |
| Name (max. 40 Zeichen) | text | EVG28 |
| Name (max. 40 Zeichen) | text | EVG29 |
| Name (max. 40 Zeichen) | text | EVG30 |
| Name (max. 40 Zeichen) | text | EVG31 |
| Name (max. 40 Zeichen) | text | EVG32 |
| Name (max. 40 Zeichen) | text | EVG33 |
| Name (max. 40 Zeichen) | text | EVG34 |
| Name (max. 40 Zeichen) | text | EVG35 |
| Name (max. 40 Zeichen) | text | EVG36 |
| Name (max. 40 Zeichen) | text | EVG37 |
| Name (max. 40 Zeichen) | text | EVG38 |
| Name (max. 40 Zeichen) | text | EVG39 |
| Name (max. 40 Zeichen) | text | EVG40 |
| Name (max. 40 Zeichen) | text | EVG41 |
| Name (max. 40 Zeichen) | text | EVG42 |
| Name (max. 40 Zeichen) | text | EVG43 |
| Name (max. 40 Zeichen) | text | EVG44 |
| Name (max. 40 Zeichen) | text | EVG45 |
| Name (max. 40 Zeichen) | text | EVG46 |
| Name (max. 40 Zeichen) | text | EVG47 |
| Name (max. 40 Zeichen) | text | EVG48 |
| Name (max. 40 Zeichen) | text | EVG49 |
| Name (max. 40 Zeichen) | text | EVG50 |
| Name (max. 40 Zeichen) | text | EVG51 |
| Name (max. 40 Zeichen) | text | EVG52 |
| Name (max. 40 Zeichen) | text | EVG53 |
| Name (max. 40 Zeichen) | text | EVG54 |
| Name (max. 40 Zeichen) | text | EVG55 |
| Name (max. 40 Zeichen) | text | EVG56 |
| Name (max. 40 Zeichen) | text | EVG57 |
| Name (max. 40 Zeichen) | text | EVG58 |
| Name (max. 40 Zeichen) | text | EVG59 |
| Name (max. 40 Zeichen) | text | EVG60 |
| Name (max. 40 Zeichen) | text | EVG61 |
| Name (max. 40 Zeichen) | text | EVG62 |
| Name (max. 40 Zeichen) | text | EVG63 |
| Name (max. 40 Zeichen) | text | EVG64 |
| Hardware_type | list | DG/S1.64.1.1 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Dali gateway 1 channel KNX 1.4 latest | $A0AA | 62B2 | 2026-11-25 | 834 KB | Download |
| Dali gateway 1 channel KNX 1.0 | $A0AA | A8BB | 2026-11-25 | 777 KB | Download |
About this file
This is the official ETS product database for the VIMAR 01542 Dali gateway 1 channel (01542), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from VIMAR
- 01500.1 Power supply,320mA,MDRC 01500.1
- 01500.2 Power supply unit 320mA KNX 01500.2
- 01501.1 Power supply,640mA,MDRC 01501.1
- 01501.2 Power supply unit 640mA KNX 01501.2
- 01504.1 Line-/Area Coupler, MDRC 01504.1
- 01504.2 Line coupler 01504.2
- 01506 By-me Plus KNX Secure TP router 01506
- 01507 By-me Plus KNX Secure IP router 01507
- 01510 4 Fold Input 01510
- 01514 2Inputs/Outputs Interface 01514
- 01515.1 Universal Interfaces, 4-fold 01515.1
- 01521 Switch actuator 12-fold 10A 01521