FCA 2 4920210
Theben AG · Order number 4920210 · Heizung, Klima, Lüftung › Fan Coil Aktor
Fan Coil Actuator, 3 Steps, 2-/3-point valves, internal/external controller
Download .knxprod FCA 2 Fan Coil Actuator 0-10V 1.0 · 140 KB
Product
| Manufacturer | Theben AG |
|---|---|
| Product name | FCA 2 |
| Order number | 4920210 |
| Hardware | FCA 2 |
| Medium | Twisted Pair |
| Bus current (mA) | 7 |
| Rail mounted | Yes |
| Width (mm) | 70 |
| Registration | Certified · 2016-01-06 |
| Languages | de-DE, en-US, es-ES, fr-FR, it-IT, nl-NL |
| Catalog entry | M-0048_H-4920210-1_HP-492D-10-F34C_CI-4920210-1 |
| Fingerprint | F34C |
| SHA-256 | 9d8f1d330fdd0638bd49eef58cf705f8a1d22d53468e35a2d479744b506c8d27 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: FCA 2 Fan Coil Actuator 0-10V 1.0
| Application number | $492D |
|---|---|
| Version | 1.0 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | No |
| Parameters | 152 |
| Group objects | 62 |
Group objects (62)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Actuating value heating | Receive | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 0 | Actuating value heating/cooling | Transmit | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 0 | Actuating value heating/cooling | Receive | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 0 | Actuating value heating | Transmit | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 0 | Actuating value cooling | Transmit | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 0 | Actuating value for fan | Receive | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 0 | Actuating value cooling | Receive | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 1 | Enable cooling | 1 = Enable cooling | 1 Bit | 1.3 enable | CRWU |
| 1 | Actuating value cooling | Receive | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 1 | Heating/cooling | Heating = 1, Cooling = 0 | 1 Bit | 1.1 switch | CRWU |
| 1 | Actuating value cooling | Transmit | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 1 | disable heating | 1 = Heating disabled | 1 Bit | 1.1 switch | CRWU |
| 1 | Heating / cooling | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRWU |
| 2 | Heating status | Report | 1 Bit | 1.1 switch | CRTU |
| 3 | Cooling status | Report | 1 Bit | 1.1 switch | CRTU |
| 4 | Fan step | Report | 1 Byte | 5.10 counter pulses (0..255) | CRTU |
| 4 | Fan speed | Report | 1 Byte | 5.10 counter pulses (0..255) | CRTU |
| 5 | Auxilliary relay | Switching | 1 Bit | 1.1 switch | CRWU |
| 5 | Auxilliary relay status | Report | 1 Bit | 1.1 switch | CRTU |
| 6 | Lock additional ventilation | 1 = Lock | 1 Bit | 1.1 switch | CRWU |
| 7 | Fan lock | 1 = Lock | 1 Bit | 1.1 switch | CRWU |
| 8 | Forced fan step | Fan control via level | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 8 | Fan speed in forced mode | Fan control with % value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 8 | Forced fan step | Fan control with % value | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 9 | Limitation of fan step (1-2-3) | 0=Fan OFF 1-3=max. level | 1 Byte | 5.10 counter pulses (0..255) | CRWU |
| 9 | Limitation of fan step in % | 0 = Fan OFF 1..100% = max.step | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 9 | Limitation of fan step in % | 0=Fan OFF 1..100%=max. | 1 Byte | 5.1 percentage (0..100%) | CRWU |
| 10 | Fan off | Report | 1 Bit | 1.1 switch | CRTU |
| 11 | Fan step 1 | Report | 1 Bit | 1.1 switch | CRTU |
| 12 | Fan step 2 | Report | 1 Bit | 1.1 switch | CRTU |
| 13 | Fan step 3 | Report | 1 Bit | 1.1 switch | CRTU |
| 14 | Status of window contact at E1 | Report | 1 Bit | 1.1 switch | CRTU |
| 14 | Actual value from E1 | Report | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 15 | Manual mode | Receive: auto=1, forced=0 | 1 Bit | 1.1 switch | CRWU |
| 15 | Manual mode | Receive: forced=1, auto=0 | 1 Bit | 1.1 switch | CRWU |
| 16 | Drip tray monitoring status | Report | 1 Bit | 1.1 switch | CRTU |
| 16 | Drip tray monitoring status | Input | 1 Bit | 1.1 switch | CRWU |
| 16 | Status of window contact at E2 | Report | 1 Bit | 1.1 switch | CRTU |
| 17 | Dew point alarm | Input | 1 Bit | 1.1 switch | CRWU |
| 18 | Outdoor temperature | Input | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 19 | Adjust set point | Delta in K | 2 Bytes | 9.2 temperature difference (K) | CRTU |
| 19 | Adjust set point | Value in °C | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 20 | Sensor failure | Sensor failure | 1 Bit | 1.1 switch | CRTU |
| 20 | Actuating value loss | 1 = Actuating value loss | 1 Bit | 1.1 switch | CRTU |
| 21 | Operating mode preset | operating mode preset | 1 Byte | CRWU | |
| 21 | Night mode <-> Standby | 1 = Night mode | 1 Bit | 1.1 switch | CRWU |
| 22 | Presence | Input for presence signal | 1 Bit | DPT.1 | CRWU |
| 22 | Comfort | 1 = Comfort mode | 1 Bit | 1.1 switch | CRWU |
| 23 | Window | Input for window contact | 1 Bit | DPT.1 | CRWU |
| 23 | Frost protection | 1 = Frost protection | 1 Bit | 1.1 switch | CRWU |
| 24 | Current operating mode | Transmit | 1 Byte | CRTU | |
| 25 | Manual adjustment | Receive | 2 Bytes | 9.2 temperature difference (K) | CRWU |
| 26 | Base set point | Receive | 2 Bytes | 9.1 temperature (°C) | CRWU |
| 27 | Current set point value | Transmit | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 28 | Heating/cooling | Heating = 1, Cooling = 0 | 1 Bit | 1.1 switch | CRWU |
| 28 | Heating/cooling | Heating = 0, Cooling = 1 | 1 Bit | 1.1 switch | CRWU |
| 29 | No energy medium | 1 = Wrong energy medium | 1 Bit | 1.1 switch | CRTU |
| 29 | Heating required but heating disabled | 1 = Heating disabled | 1 Bit | 1.1 switch | CRTU |
| 29 | Cooling required but cooling disabled | 1 = Cooling disabled | 1 Bit | 1.1 switch | CRTU |
| 30 | Fan duty time since last filter change | Time in hours | 2 Bytes | DPT.7 | CRTU |
| 31 | Change filter | 1 = Change 0 = Reset | 1 Bit | 1.1 switch | CRWTU |
| 32 | Testmode active | Report | 1 Bit | 1.3 enable | CRTU |
Parameters (123)
| Parameter | Type | Default |
|---|---|---|
| General | list | Page |
| Supported functions | list | heating and cooling |
| Heating installation | list | Fan coil |
| Model of heat exchanger | list | Fan coil |
| Cooling installation | list | Fan coil |
| Kind of installation | list | 2-pipe system |
| Kind of used controler | list | remote controller |
| Format object heating/cooling | list | DPT100 (Heating= 1 / Cooling=0) |
| Test mode | list | disabled |
| Report filter change | list | no |
| Activate monitoring of actuating value | list | no |
| Switch fan between Auto and forced mode | list | via obj. Forced/auto, forced = 1 |
| Fan | list | Page |
| Fan controller | list | standard (1-3 step) |
| Number of fan steps | list | 3 steps |
| Switch-on threshold for fan step 1 | list | 10 % |
| Switch ON threshold | list | 10 % |
| Switch-on threshold for fan step 2 | list | 40 % |
| Switch-on threshold for fan step 3 | list | 70 % |
| Fan starting strategy | list | directly |
| Restart delay (for split-system air conditioners) | list | no delay (fan / fan coil unit) |
| Switching delay between 2 fan steps | list | 0,5 s |
| Minimum time to stay within a fan step | list | 2 min |
| Hysteresis between the fan steps | list | 10 % |
| Additional ventilation | list | no |
| Value for supplementary ventilation | list | 40 % |
| Warm start | list | no warm start |
| Follow-up time for utilisation of the remaining energy | list | no follow-up |
| Format compulsory control and limitation | list | percentage |
| Cyclical transmission of fan object | list | don´t transmit cyclically |
| Cyclical transmission of fan step | list | Format %, don´t transmit cyclically |
| Heating valve | list | Page |
| Heating/cooling valve | list | Page |
| Cooling valve | list | Page |
| Time for the valve to close | list | 3 min |
| New position at change of | list | 5 % |
| Open for actuating value above | list | 0,4 % |
| Minimum valve position | list | 0 % |
| Maximum valve position above | list | 50 % |
| Maximum valve position | list | 100 % |
| Cyclical transmission of heating status | list | don´t transmit cyclically |
| Delay between heating and cooling | list | 0 min |
| Cyclical transmission of cooling status every | list | don´t transmit cyclically |
| Cyclical transmission of heating/cooling status | list | don´t transmit cyclically |
| Auxilliary relay | list | Page |
| Switch ON auxilliary relay | list | via object |
| Cyclical transmission of aux. relay status every | list | don´t transmit cyclically |
| E1 | list | Page |
| Function of E1 | list | E1 = window contact |
| Direction of operation of window contact | list | Contact closed = window closed |
| Actual value offset in 0.1 K (-50..50) | signedInt -50…50 | 0 |
| Transmission of actual value at change of | list | every 0,5 K |
| Cyclical transmission of window contact | list | don´t transmit cyclically |
| Cyclical transmission of actual value | list | don´t transmit cyclically |
| Actuating value in case of sensor failure or short circuit | list | 20 % |
| Report sensor failure (1 = failure) | list | only if object value = 1 |
| Report cyclically | list | every 30 min |
| Drip tray monitoring | list | Page |
| E2 | list | Page |
| Source for drip tray monitoring | list | E2 |
| Direction of operation of contact | list | contact closed = condensate |
| Direction of action of E2 | list | contact closed = condensate |
| Direction of operation of contact | list | contact closed = window closed |
| Behaviour in case of drip tray alarm | list | cooling and fan OFF |
| Cyclical transmission of alarm status | list | don´t transmit cyclically |
| Cyclical transmission of E2 status | list | don´t transmit cyclically |
| Set point adjustment | list | Page |
| Set point adjustment | list | yes |
| Set point adjustment from | list | 25 °C |
| Adjustment | list | 1 K per 3 K outdoor temperature |
| Format of the adjustment value | list | relative |
| Base set point without adjustment | list | 21 °C |
| Cyclical transmission of set point adjustment | list | don´t transmit cyclically |
| Use set point adjustment for regulation | list | no |
| Set point values | list | Page |
| Base set point after reset | list | 21 °C |
| Reduction in standby operating mode | list | 2 K |
| Reduction in standby operating mode at heating | list | 2 K |
| Reduction in night operating mode | list | 5 K |
| Reduction in night operating mode at heating | list | 5 K |
| Set point value for frost protection mode | list | 6 °C |
| Set point value for frost protection (at heating) | list | 6 °C |
| Dead zone between heating and cooling | list | 2 K |
| Cyclical transmission of current set point value | list | don´t transmit cyclically |
| Increasing in standby mode at cooling | list | 2 K |
| Increasing in standby mode | list | 2 K |
| Increasing in night mode at cooling | list | 5 K |
| Increasing in night mode | list | 5 K |
| Set point value for heat protection (at cooling) | list | 42 °C ( = no heat protection) |
| Set point value for heat protection | list | 42 °C ( = no heat protection) |
| Current set point value in comfort mode | list | transmit actual temp. setpoint (heating<>cooling) |
| Regulation | list | Page |
| Setting of control parameters | list | standard |
| Proportional band of heating controller | list | 2 K |
| Integral action time constant of heating controller | list | 150 min |
| Proportional band of cooling controller | list | 4 K |
| Integral time of cooling controller | list | 90 min |
| Heating/cooling | list | auto |
| Transmission of actuating value | list | at change of 5 % |
| Cyclical transmission of actuating value every | list | 15 min |
| Report, when no energy medium | list | only if object value = 1 |
| Report, when heating required but heating disabled | list | only if object value = 1 |
| Report, when cooling required but cooling disabled | list | only if object value = 1 |
| Operating mode and operation | list | Page |
| Operating mode after reset | list | standby |
| Cyclical transmission of current op. mode every | list | don´t transmit cyclically |
| Mode setting objects | list | new: operating mode, presence, window state |
| Kind of presence detector | list | presence detector |
| Time for comfort extension | list | 2 h |
| Manual offset applies | list | for comfort, standby and night |
| Limitation of manual value increasing/decreasing | list | +/- 3 K |
| Filter monitoring | list | Page |
| Message for filter change after duty time of (1..127 weeks) | unsignedInt 1…127 | 12 |
| Transmit filter replacement cyclically | list | only at filter change |
| Transmit fan duty time (in hours) | list | never transmit (reading is possible) |
| Cycle time for filter replacement and fan duty time | list | every 60 min |
| Monitor actuating value | list | yes |
| Actuating value loss | list | Page |
| Monitoring time for actuating value | list | 60 min |
| Substitute actuating value emergency program | list | 20 % |
| Report actuating value loss cyclically (1 = no act. value) | list | only if object value = 1 |
| Download bereits bearbeitet ? | list | no |
| 1. Download OK | list | yes |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| FCA 2 Fan Coil Actuator 0-10V 2.0 latest | $492D | B765 | 2026-11-25 | 186 KB | Download |
| FCA 2 Fan Coil Actuator 0-10V 1.0 | $492D | F34C | 2026-11-25 | 140 KB | Download |
About this file
This is the official ETS product database for the Theben AG FCA 2 (4920210), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Theben AG
- FCA 1 4920200
- RAM 712 7129200
- RAM 713 S 7139201
- RAM 713 Fan Coil 7139202
- AMUN 716 S 7169230
- RAMSES 718 S 7189200
- RAMSES 718 P 7189210
- RAM 770 7709200
- VARIA 824 / 826 8249200 / 8269200
- Set basic KNX Multi 9070900
- Theben dummy device secure -
- TheLuxa P300 1019610