Room Temperature Controller UP237KB_1 5WG1 237-2KB_1
Siemens · Order number 5WG1 237-2KB_1 · Heating, Air conditioning, Ventilation › Thermostat › Wall Mounted Devices › UP 254KB_3, UP237KB_1 DELTA style / i-system
For heating and cooling
Download .knxprod 0705 CO Room Temperature Controller H+C 803002 0.2 · 100 KB
Product
| Manufacturer | Siemens |
|---|---|
| Product name | Room Temperature Controller UP237KB_1 |
| Order number | 5WG1 237-2KB_1 |
| Hardware | #Raumtemperaturregler Heizen/Kühlen UP 2__KB |
| Medium | Twisted Pair |
| Bus current (mA) | 14 |
| Rail mounted | No |
| Registration | Registered · 2012-01-12 |
| Languages | en-US, de-DE |
| Catalog entry | M-0001_H-hp.5F00268-2_HP-8030-02-DF56_CI-5WG1.20237.2D2KB.5F1-1 |
| Fingerprint | DF56 |
| SHA-256 | 14e3a5c31cb9efd0b1db926b12505ba3cf459af79606bed2f8616d3352c5de77 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: 0705 CO Room Temperature Controller H+C 803002 0.2
| Application number | $8030 |
|---|---|
| Version | 0.2 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0f |
| Parameters | 219 |
| Group objects | 36 |
Group objects (36)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Temperature, actual value internal sensor (°C) | send | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 1 | Temperature, actual value internal sensor (°C) | receive / send | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 2 | Temperature, actual value ext. sensor (°C) | send | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 3 | Base setpoint (°C) | receive / send | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 4 | Setpoint adjustment (Kelvin) | receive / send | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 5 | Temperature, setpoint value (°C) | send | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 6 | Comfort mode | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 7 | Pre-comfort mode | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 8 | Economy mode | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 9 | Protection mode | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 10 | Permanent protection mode | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 11 | Automatic | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 12 | Thermostat | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 13 | Heating / cooling | 1= heating / 0 = cooling | 1 Bit | 1.1 switch | CRWTU |
| 14 | Frost alarm | On / Off | 1 Bit | 1.1 switch | CRTU |
| 15 | Heat alarm | On / Off | 1 Bit | 1.1 switch | CRTU |
| 16 | Dew point alarm | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 17 | Window 1 | 1= open / 0 = close | 1 Bit | 1.1 switch | CRWTU |
| 18 | Window 2 | 1= open / 0 = close | 1 Bit | 1.1 switch | CRWTU |
| 19 | Window 3 | 1= open / 0 = close | 1 Bit | 1.1 switch | CRWTU |
| 20 | Window 4 | 1= open / 0 = close | 1 Bit | 1.1 switch | CRWTU |
| 21 | Presence | On / Off | 1 Bit | 1.1 switch | CRWTU |
| 22 | Status extended comfort mode | On / Off | 1 Bit | 1.1 switch | CRTU |
| 23 | Room mode | 1... 4 | 1 Byte | CWTU | |
| 24 | Status room mode | 1... 4 | 1 Byte | CRT | |
| 25 | Controller-Status (Eberle) | 8-bit Status | 1 Byte | CRWTU | |
| 26 | Controller-Status (RHCC) | 16-bit Status | 2 Bytes | CRWTU | |
| 27 | Heating / cooling, control value switching | On / Off | 1 Bit | 1.1 switch | CRT |
| 27 | Heating / cooling, control value continuous | 0 ... 100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | Heating, control value switching | On / Off | 1 Bit | 1.1 switch | CRT |
| 27 | Heating, control value continuous | 0 ... 100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 28 | Heating, control value sequence 2 | 0 ... 100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 29 | Cooling, control value switching | On / Off | 1 Bit | 1.1 switch | CRT |
| 29 | Cooling, control value continuous | 0 ... 100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 30 | Cooling, control value sequence 2 | 0 ... 100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 31 | Control value | 0 ... 100% | 1 Byte | 5.1 percentage (0..100%) | CRWT |
Parameters (82)
| Parameter | Type | Default |
|---|---|---|
| Internal sensor, offset to measured value | list | no offset |
| ETS download flag | unsignedInt 0…255 | 255 |
| $first start flag | unsignedInt 0…255 | 0 |
| >> Test | list | $disable |
| $>> Test: value in | list | $enable |
| $>> Test: direction of control value | list | $out |
| $>> Test: repetition time | list | off |
| Setpoint value setting | list | via setpoint value shift |
| Setpoint value setting | list | directly in °C |
| Setpoint value shift range | list | 5.0 °C / 41 F |
| Rotary lock | list | disabled |
| Push button | list | enabled |
| Time for long pressing | list | 1.0 s |
| $Dummy | unsignedInt 0…255 | 3 |
| Presence object | list | no |
| Permanent protection mode object | list | no |
| Number of window contacts | list | 0 |
| Reaction upon an open window | list | at once |
| 8-bit objects room mode / room mode status | list | no |
| 8-bit object controller status (Eberle) | list | no |
| 16-bit object controller status (RHCC) | list | no |
| Operating mode controller | list | heating + cooling |
| Control value output | list | on separate object |
| Heating | list | PI-control |
| Sequence control | list | without sequence control |
| Cooling | list | PI-control |
| Dead zone between heating und cooling | list | ±1,50 K |
| active modes | unsignedInt 0…255 | 18 |
| Room modes | list | comfort/pre-comfort/economy/protection mode |
| Duration for extended comfort mode | list | 30 minutes |
| Status object for extended comfort mode | list | no |
| Raum-Betriebsart nach Download | list | protection mode |
| Room mode after bus voltage recovery | list | as before bus voltage failure |
| Basic setpoint value and actual value of external sensor on restart | list | 22 °C / 71.6 F |
| Send status objects on initialisation | list | delayed after 5s |
| External temperature sensor | list | no |
| Cycle time for polling of external temperature sensor | list | 10 minutes |
| External sensor, offset to measured value | list | no offset |
| External / internal weighting | list | only internal sensor |
| Change of actual temperature value for automatic sending | list | 0.5 K |
| Cycle time for automatic sending of the actual temperature value | list | 10 minutes |
| Reduction heating pre-comfort mode | list | 2 K |
| Reduction heating economy mode | list | 4 K |
| Increase cooling pre-comfort mode | list | 2 K |
| Increase cooling economy mode | list | 4 K |
| Setpoint frost protection for heating | list | 7 °C / 44.6 F |
| Setpoint heat protection for cooling | list | 35 °C / 95 F |
| Threshold for frost alarm | list | 0.5 °C / 32.9 F |
| Threshold for heating alarm | list | 40 °C / 104 F |
| Cycle time for sending frost-/heat alarm | list | 10 minutes |
| Operating mode heating | unsignedInt 0…255 | 1 |
| Operating mode cooling | unsignedInt 0…255 | 1 |
| Hysteresis | list | -1,00 K |
| Proportional range | list | 3.0 °C / 37.4 F |
| Double hysteresis in economy/ protection mode | list | yes |
| Integration time | list | 30 minutes |
| Cycle time, 2 level control | list | 5 minutes |
| $Dummy | unsignedInt 0…255 | 1 |
| Maximum control value | list | 100% |
| Minimum control value | list | 0% |
| Direction / scaling of control value | list | +100 % (normal) |
| Valve always open, if positioning value is above [in %] | list | 100% |
| Valve always closed, if positioning value is below [in %] | list | 1% |
| Hysteresis | list | +1,00 K |
| Type of control value output heating / cooling | list | continuous (8-bit) |
| Type of control value output | list | continuous (8-bit) |
| Change of control value for automatic sending | list | 5% |
| Cycle time for cyclical sending of the control value | list | 15 minutes |
| valve type | unsignedInt 0…255 | 1 |
| Direction of the control value | list | normal |
| Pulse width modulation period time | list | 10 minutes |
| Number of valves | unsignedInt 0…255 | 1 |
| $Heat / Cool als enable | unsignedInt 0…255 | 185 |
| $Heat / Cool als status | unsignedInt 0…255 | 0 |
| Value for heating, sequence 2 starts from [in %] | unsignedInt 0…255 | 100 |
| Value for heating, sequence 2 starts from [in %] | unsignedInt 5…95 | 50 |
| Sequence 2, change of control value for automatic sending | list | 5% |
| Sequence 2 cycle time for automatic sending | list | 15 minutes |
| Value for cooling, sequence 2 starts from [in %] | unsignedInt 0…255 | 100 |
| Value for cooling, sequence 2 starts from [in %] | unsignedInt 5…95 | 50 |
| Setpoint value shift range | list | 15 minutes |
| Deadzone between heating and cooling | unsignedInt 0…500 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| 0705 CO Room Temperature Controller H+C 803002 0.2 latest | $8030 | DF56 | 2026-11-25 | 100 KB | Download |
About this file
This is the official ETS product database for the Siemens Room Temperature Controller UP237KB_1 (5WG1 237-2KB_1), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Siemens
- Thermo drive actuator RS510/K23 5WG1 510-2KB23
- Valve actuator AP 562/02 5WG1 562-7AB02
- Thermal Drive Actuator N 605D41, 6 x AC 24...230 V 5WG1605-1DB41
- Thermal Drive Actuator RL 605D23, 2 x AC 24...230 V 5WG1605-4DB23
- Bus Transceiver Module UP 117/12 5WG1 117-2AB12
- Control Module Box AP 118 5WG1 118-4AB01
- Choke N 120/02 5WG1 120-1AB02
- Power supply unit N 125/02 (230V / 160mA) 5WG1 125-1AB02
- Power supply unit N 125/12 (230V / 320mA) 5WG1 125-1AB12
- Power supply unit N 125/22 (230V / 640mA) 5WG1 125-1AB22
- Decentralized Power Supply RL 125/23 5WG1 125-4AB23
- Power supply unit JB 125C33 (277V/160mA) 5WG1 125-4CB33