KNX Air quality Combi Sensor & Control (V5.0) EL/ED/SD-xxxx-KNX
sensortec AG · Order number EL/ED/SD-xxxx-KNX · KNX Room Sensor & Control Options (V5.0) › ED/EL/SD.KNX Air quality combination sensor & control
KNX Air quality Combi Sensor & Control (V5.0)
Download .knxprod KNX Room Sensor & Control Options 5.1 · 120 KB
Product
| Manufacturer | sensortec AG |
|---|---|
| Product name | KNX Air quality Combi Sensor & Control (V5.0) |
| Order number | EL/ED/SD-xxxx-KNX |
| Product text | KNX Room Sensor & Control Options (V5.0) |
| Hardware | Hardware |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Registered · 2026-06-10 |
| Languages | de-DE, fr-FR, en-US |
| Catalog entry | M-0231_H--41_HP-0001-51-138A_CI-EL.2FED.2FSD.2Dxxxx.2DKNX-1 |
| Fingerprint | 138A |
| SHA-256 | 79e9d64cbc09c72bf3a3923c4c2073800b55a3679d3ac9ffe206e34d28d40fa6 |
| First seen | 2026-11-25 |
| Markets | Switzerland |
Application program: KNX Room Sensor & Control Options 5.1
| Application number | $0001 |
|---|---|
| Version | 5.1 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 94 |
| Group objects | 22 |
Group objects (22)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Temperature | DPT 9 Temperature | 2 Bytes | DPT.9 | CRT |
| 2 | Humidity | DPT 9 Humidity | 2 Bytes | DPT.9 | CRT |
| 3 | Setpoint | DPT 9 Setpoint | 2 Bytes | DPT.9 | CRT |
| 3 | Setpoint | DPT 5 Setpoint | 1 Byte | DPT.5 | CRT |
| 4 | Button/Led | DPT 1 Button/Led | 1 Bit | DPT.1 | CRWT |
| 5 | Air quality eTVOC ppb | DPT 9 eTVOC | 2 Bytes | CRT | |
| 6 | Air quality eCO2 ppm | DPT 9 eCO2 | 2 Bytes | DPT.9 | CRT |
| 7 | Air quality index AQI-S | DPT 7 AQI_S | 2 Bytes | CRT | |
| 8 | Air quality index AQI-UBA | DPT 5 AQI_UBA | 1 Byte | CRT | |
| 9 | Air quality Prozent | DPT 9 AQI | 2 Bytes | DPT.9 | CRT |
| 10 | Air quality CO2 | DPT 9 CO2 | 2 Bytes | 9.8 parts/million (ppm) | CRWT |
| 11 | Air quality monitor green | DPT 1 AQM green | 1 Bit | DPT.1 | CRT |
| 12 | Air quality monitor orange | DPT 1 AQM orange | 1 Bit | DPT.1 | CRT |
| 13 | Air quality monitor red | DPT 1 AQM red | 1 Bit | DPT.1 | CRT |
| 14 | Fan stage Auto/Manual | DPT 1 Fan Auto/Manual | 1 Bit | DPT.1 | CRWT |
| 15 | Fan stage 0 | DPT 1 Fan stage 0 | 1 Bit | DPT.1 | CRWT |
| 16 | Fan stage 1 | DPT 1 Fan stage 1 | 1 Bit | DPT.1 | CRWT |
| 17 | Fan stage 2 | DPT 1 Fan stage 2 | 1 Bit | DPT.1 | CRWT |
| 18 | Fan stage 3 | DPT 1 Fan stage 3 | 1 Bit | DPT.1 | CRWT |
| 19 | Fan stage value (bit) | DPT 5 Fan stage (bit) | 1 Byte | DPT.5 | CRWT |
| 19 | Fan stage value (percent) | DPT 5 Fan stage (percent) | 1 Byte | DPT.5 | CRWT |
| 20 | Option | DPT 16 Option | 14 Bytes | DPT.16 | CRT |
Parameters (41)
| Parameter | Type | Default |
|---|---|---|
| Transimition condition | list | Read only |
| Change | list | 1.0 °C |
| Timebase | list | Minutes |
| Cycletime | unsignedInt 1…250 | 10 |
| Transimition condition | list | Not used |
| Change | list | 5% |
| Type | list | Temperature °C |
| Temperature difference min. [K] | list | -5 K |
| Temperature difference max. [K] | list | 5 K |
| Change [ppb] | unsignedInt 10…50 | 10 |
| Change [ppm] | unsignedInt 20…100 | 20 |
| Type Fan value | list | Bitfield |
| Fan value stage Auto (%) | unsignedInt 0…100 | 10 |
| Fan value (%) | unsignedInt 0…100 | 0 |
| Fan value stage 1 (%) | unsignedInt 0…100 | 25 |
| Fan value stage 2 (%) | unsignedInt 0…100 | 50 |
| Fan value stage 3 (%) | unsignedInt 0…100 | 75 |
| Temperature offset [ 0.1 °C] | signedInt -50…50 | 0 |
| Led switch off time (S10) [Sec.] | unsignedInt 0…255 | 0 |
| Reset from level 0 | list | NO |
| AQM limit TVOC orange | unsignedInt 0…65535 | 100 |
| AQM limit TVOC red | unsignedInt 0…65535 | 300 |
| AQM limit CO2 orange | unsignedInt 0…65535 | 1000 |
| AQM limit CO2 red | unsignedInt 0…65535 | 1400 |
| AQM Hyterese | unsignedInt 0…65535 | 10 |
| Reset from level Auto | list | NO |
| Reset to stage | list | Position A |
| Reset time | unsignedInt 1…250 | 10 |
| Type AQM | list | Off |
| Reset from level 2 | list | NO |
| Reset from level 3 | list | NO |
| Reset from level 1 | list | NO |
| Change | unsignedInt 0…255 | 10 |
| Temperature min. [°C] | unsignedInt 5…32 | 18 |
| Temperature max. [°C] | unsignedInt 5…32 | 32 |
| Filter Averaging time temperature | list | 2s (default) |
| Filter Averaging time humidity | list | 2s (default) |
| Filter Averaging time VOC | list | 2min. (default) |
| Filter Averaging time CO2 | list | 1min. (default) |
| Humidity offset [%rH] | signedInt -20…20 | 0 |
| CO2 offset [ppm] | signedInt -500…500 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Room Sensor & Control Options 5.1 latest | $0001 | 138A | 2026-11-25 | 120 KB | Download |
About this file
This is the official ETS product database for the sensortec AG KNX Air quality Combi Sensor & Control (V5.0) (EL/ED/SD-xxxx-KNX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from sensortec AG
- RAx07-KNX V4 Luftqualität Kombi-Sensor & Bedienung RAx07-KNX V4