KNX Database
Schneider Electric Industries SAS MTN6730-0002 SpaceLogic KNX Valve Drive Controller

SpaceLogic KNX Valve Drive Controller MTN6730-0002

Schneider Electric Industries SAS · Order number MTN6730-0002 · 7.1 Heating/Single Room Thermostat › 7.1.2 Heating/Switch actuator

MTN6730-0002

Download .knxprod Valve Drive Controller 2073/1.2 1.2 · 1.1 MB

Product

ManufacturerSchneider Electric Industries SAS
Product nameSpaceLogic KNX Valve Drive Controller
Order numberMTN6730-0002
HardwareSpaceLogic KNX Valve Drive Controller
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)72
RegistrationCertified · 2020-08-24
Languagesen-US, de-DE, fr-FR, da-DK, nl-NL, it-IT, sv-SE, es-ES, ru-RU
Catalog entryM-0064_H-100.20.2F.2F.20MTN6730.2D0002-1-O000A_HP-2073-12-5A7B-O000A_CI-MTN6730.2D0002-2
Fingerprint5A7B
SHA-25697cf073aae81c2446a626fbbfe59d3a90b3b2bf4a4ccf40a3dccbf7a5779bf88
First seen2026-11-25
Markets59 markets

Application program: Valve Drive Controller 2073/1.2 1.2

Application number$2073
Version1.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters2982
Group objects592
Group objects (592)
NoNameFunctionSizeDPTFlags
1Valve outputs - outputFailure of operating voltage1 Bit1.5 alarmCRTU
2Pump - outputSwitch pump1 Bit1.1 switchCRTU
3Pump - inputExternal pump control1 Bit1.1 switchCWU
4Valve outputs - outputLargest command value1 Byte5.1 percentage (0..100%)CRTU
5Valve outputs - inputExternal largest command value1 Byte5.1 percentage (0..100%)CWU
6Valve outputs - outputHeat requirement1 Bit1.2 booleanCRTU
7Valve outputs - inputExternal heat requirement1 Bit1.2 booleanCWU
8Operating mode - inputSummer / winter change-over1 Bit1.2 booleanCWU
9Valve outputs - inputReset short-circuit / overload1 Bit1.15 resetCWU
10Valve outputs - outputCollective feedback status4 Bytes27.1 bit-combined info on/offCTU
10Valve outputs - outputCollective feedback status4 Bytes27.1 bit-combined info on/offCRU
11Energy saving mode - inputActivate / deactivate1 Bit1.3 enableCWU
12Service mode - inputActivate / deactivate2 Bit2.1 switch controlCWU
13Service mode - outputStatus active / inactive1 Bit1.2 booleanCRTU
14Manual operation - inputDisabling1 Bit1.3 enableCWU
15Manual operation - outputStatus1 Bit1.2 booleanCRTU
20Valve output 1 ({{131:Name}}) - inputCommand value1 Bit1.1 switchCWU
21Valve output 1 ({{131:Name}}) - inputCommand value1 Byte5.1 percentage (0..100%)CWU
22Valve output 1 ({{131:Name}}) - outputFeedback valve command value1 Bit1.1 switchCRU
22Valve output 1 ({{131:Name}}) - outputFeedback valve command value1 Bit1.1 switchCTU
23Valve output 1 ({{131:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CRU
23Valve output 1 ({{131:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CTU
24Valve output 1 ({{131:Name}}) - inputForced position1 Bit1.3 enableCWU
25Valve output 1 ({{131:Name}}) - outputCommand value fault1 Bit1.15 resetCRTU
26Valve output 1 ({{131:Name}}) - inputCommand value limit1 Bit1.2 booleanCWU
27Valve output 1 ({{131:Name}}) - inputValve rinsing start / stop1 Bit1.3 enableCWU
27Valve output 1 ({{131:Name}}) - inputValve rinsing start1 Bit1.3 enableCWU
28Valve output 1 ({{131:Name}}) - outputValve rinsing status1 Bit1.2 booleanCRTU
29Valve output 1 ({{131:Name}}) - outputSignal short-circuit /overload1 BitDPT.1CRTU
30Valve output 1 ({{131:Name}}) - outputFeedback combined valve status1 ByteCTU
30Valve output 1 ({{131:Name}}) - outputFeedback combined valve status1 ByteCRU
31Valve output 1 ({{131:Name}}) - inputOperating hours counter limit value2 BytesDPT.7CWU
31Valve output 1 ({{131:Name}}) - inputOperation hours counter start value2 Bytes7.7 time (h)CWU
32Valve output 1 ({{131:Name}}) - inputReset operating hours counter1 Bit1.15 resetCWU
33Valve output 1 ({{131:Name}}) - outputValue operating hours counter2 BytesDPT.7CRTU
34Valve output 1 ({{131:Name}}) - outputOperating hours counter elapsed1 Bit1.2 booleanCRTU
70Valve output 2 ({{139:Name}}) - inputCommand value1 Bit1.1 switchCWU
71Valve output 2 ({{139:Name}}) - inputCommand value1 Byte5.1 percentage (0..100%)CWU
72Valve output 2 ({{139:Name}}) - outputFeedback valve command value1 Bit1.1 switchCRU
72Valve output 2 ({{139:Name}}) - outputFeedback valve command value1 Bit1.1 switchCTU
73Valve output 2 ({{139:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CRU
73Valve output 2 ({{139:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CTU
74Valve output 2 ({{139:Name}}) - inputForced position1 Bit1.3 enableCWU
75Valve output 2 ({{139:Name}}) - outputCommand value fault1 Bit1.15 resetCRTU
76Valve output 2 ({{139:Name}}) - inputCommand value limit1 Bit1.2 booleanCWU
77Valve output 2 ({{139:Name}}) - inputValve rinsing start / stop1 Bit1.3 enableCWU
77Valve output 2 ({{139:Name}}) - inputValve rinsing start1 Bit1.3 enableCWU
78Valve output 2 ({{139:Name}}) - outputValve rinsing status1 Bit1.2 booleanCRTU
79Valve output 2 ({{139:Name}}) - outputSignal short-circuit /overload1 BitDPT.1CRTU
80Valve output 2 ({{139:Name}}) - outputFeedback combined valve status1 ByteCTU
80Valve output 2 ({{139:Name}}) - outputFeedback combined valve status1 ByteCRU
81Valve output 2 ({{139:Name}}) - inputOperating hours counter limit value2 BytesDPT.7CWU
81Valve output 2 ({{139:Name}}) - inputOperation hours counter start value2 Bytes7.7 time (h)CWU
82Valve output 2 ({{139:Name}}) - inputReset operating hours counter1 Bit1.15 resetCWU
83Valve output 2 ({{139:Name}}) - outputValue operating hours counter2 BytesDPT.7CRTU
84Valve output 2 ({{139:Name}}) - outputOperating hours counter elapsed1 Bit1.2 booleanCRTU
120Valve output 3 ({{140:Name}}) - inputCommand value1 Bit1.1 switchCWU
121Valve output 3 ({{140:Name}}) - inputCommand value1 Byte5.1 percentage (0..100%)CWU
122Valve output 3 ({{140:Name}}) - outputFeedback valve command value1 Bit1.1 switchCRU
122Valve output 3 ({{140:Name}}) - outputFeedback valve command value1 Bit1.1 switchCTU
123Valve output 3 ({{140:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CRU
123Valve output 3 ({{140:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CTU
124Valve output 3 ({{140:Name}}) - inputForced position1 Bit1.3 enableCWU
125Valve output 3 ({{140:Name}}) - outputCommand value fault1 Bit1.15 resetCRTU
126Valve output 3 ({{140:Name}}) - inputCommand value limit1 Bit1.2 booleanCWU
127Valve output 3 ({{140:Name}}) - inputValve rinsing start / stop1 Bit1.3 enableCWU
127Valve output 3 ({{140:Name}}) - inputValve rinsing start1 Bit1.3 enableCWU
128Valve output 3 ({{140:Name}}) - outputValve rinsing status1 Bit1.2 booleanCRTU
129Valve output 3 ({{140:Name}}) - outputSignal short-circuit /overload1 BitDPT.1CRTU
130Valve output 3 ({{140:Name}}) - outputFeedback combined valve status1 ByteCTU
130Valve output 3 ({{140:Name}}) - outputFeedback combined valve status1 ByteCRU
131Valve output 3 ({{140:Name}}) - inputOperating hours counter limit value2 BytesDPT.7CWU
131Valve output 3 ({{140:Name}}) - inputOperation hours counter start value2 Bytes7.7 time (h)CWU
132Valve output 3 ({{140:Name}}) - inputReset operating hours counter1 Bit1.15 resetCWU
133Valve output 3 ({{140:Name}}) - outputValue operating hours counter2 BytesDPT.7CRTU
134Valve output 3 ({{140:Name}}) - outputOperating hours counter elapsed1 Bit1.2 booleanCRTU
170Valve output 4 ({{148:Name}}) - inputCommand value1 Bit1.1 switchCWU
171Valve output 4 ({{148:Name}}) - inputCommand value1 Byte5.1 percentage (0..100%)CWU
172Valve output 4 ({{148:Name}}) - outputFeedback valve command value1 Bit1.1 switchCRU
172Valve output 4 ({{148:Name}}) - outputFeedback valve command value1 Bit1.1 switchCTU
173Valve output 4 ({{148:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CRU
173Valve output 4 ({{148:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CTU
174Valve output 4 ({{148:Name}}) - inputForced position1 Bit1.3 enableCWU
175Valve output 4 ({{148:Name}}) - outputCommand value fault1 Bit1.15 resetCRTU
176Valve output 4 ({{148:Name}}) - inputCommand value limit1 Bit1.2 booleanCWU
177Valve output 4 ({{148:Name}}) - inputValve rinsing start / stop1 Bit1.3 enableCWU
177Valve output 4 ({{148:Name}}) - inputValve rinsing start1 Bit1.3 enableCWU
178Valve output 4 ({{148:Name}}) - outputValve rinsing status1 Bit1.2 booleanCRTU
179Valve output 4 ({{148:Name}}) - outputSignal short-circuit /overload1 BitDPT.1CRTU
180Valve output 4 ({{148:Name}}) - outputFeedback combined valve status1 ByteCTU
180Valve output 4 ({{148:Name}}) - outputFeedback combined valve status1 ByteCRU
181Valve output 4 ({{148:Name}}) - inputOperating hours counter limit value2 BytesDPT.7CWU
181Valve output 4 ({{148:Name}}) - inputOperation hours counter start value2 Bytes7.7 time (h)CWU
182Valve output 4 ({{148:Name}}) - inputReset operating hours counter1 Bit1.15 resetCWU
183Valve output 4 ({{148:Name}}) - outputValue operating hours counter2 BytesDPT.7CRTU
184Valve output 4 ({{148:Name}}) - outputOperating hours counter elapsed1 Bit1.2 booleanCRTU
220Valve output 5 ({{149:Name}}) - inputCommand value1 Bit1.1 switchCWU
221Valve output 5 ({{149:Name}}) - inputCommand value1 Byte5.1 percentage (0..100%)CWU
222Valve output 5 ({{149:Name}}) - outputFeedback valve command value1 Bit1.1 switchCRU
222Valve output 5 ({{149:Name}}) - outputFeedback valve command value1 Bit1.1 switchCTU
223Valve output 5 ({{149:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CRU
223Valve output 5 ({{149:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CTU
224Valve output 5 ({{149:Name}}) - inputForced position1 Bit1.3 enableCWU
225Valve output 5 ({{149:Name}}) - outputCommand value fault1 Bit1.15 resetCRTU
226Valve output 5 ({{149:Name}}) - inputCommand value limit1 Bit1.2 booleanCWU
227Valve output 5 ({{149:Name}}) - inputValve rinsing start / stop1 Bit1.3 enableCWU
227Valve output 5 ({{149:Name}}) - inputValve rinsing start1 Bit1.3 enableCWU
228Valve output 5 ({{149:Name}}) - outputValve rinsing status1 Bit1.2 booleanCRTU
229Valve output 5 ({{149:Name}}) - outputSignal short-circuit /overload1 BitDPT.1CRTU
230Valve output 5 ({{149:Name}}) - outputFeedback combined valve status1 ByteCTU
230Valve output 5 ({{149:Name}}) - outputFeedback combined valve status1 ByteCRU
231Valve output 5 ({{149:Name}}) - inputOperating hours counter limit value2 BytesDPT.7CWU
231Valve output 5 ({{149:Name}}) - inputOperation hours counter start value2 Bytes7.7 time (h)CWU
232Valve output 5 ({{149:Name}}) - inputReset operating hours counter1 Bit1.15 resetCWU
233Valve output 5 ({{149:Name}}) - outputValue operating hours counter2 BytesDPT.7CRTU
234Valve output 5 ({{149:Name}}) - outputOperating hours counter elapsed1 Bit1.2 booleanCRTU
270Valve output 6 ({{152:Name}}) - inputCommand value1 Bit1.1 switchCWU
271Valve output 6 ({{152:Name}}) - inputCommand value1 Byte5.1 percentage (0..100%)CWU
272Valve output 6 ({{152:Name}}) - outputFeedback valve command value1 Bit1.1 switchCRU
272Valve output 6 ({{152:Name}}) - outputFeedback valve command value1 Bit1.1 switchCTU
273Valve output 6 ({{152:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CRU
273Valve output 6 ({{152:Name}}) - outputFeedback valve command value1 Byte5.1 percentage (0..100%)CTU
274Valve output 6 ({{152:Name}}) - inputForced position1 Bit1.3 enableCWU
275Valve output 6 ({{152:Name}}) - outputCommand value fault1 Bit1.15 resetCRTU
276Valve output 6 ({{152:Name}}) - inputCommand value limit1 Bit1.2 booleanCWU
277Valve output 6 ({{152:Name}}) - inputValve rinsing start / stop1 Bit1.3 enableCWU
277Valve output 6 ({{152:Name}}) - inputValve rinsing start1 Bit1.3 enableCWU
278Valve output 6 ({{152:Name}}) - outputValve rinsing status1 Bit1.2 booleanCRTU
279Valve output 6 ({{152:Name}}) - outputSignal short-circuit /overload1 BitDPT.1CRTU
280Valve output 6 ({{152:Name}}) - outputFeedback combined valve status1 ByteCTU
280Valve output 6 ({{152:Name}}) - outputFeedback combined valve status1 ByteCRU
281Valve output 6 ({{152:Name}}) - inputOperating hours counter limit value2 BytesDPT.7CWU
281Valve output 6 ({{152:Name}}) - inputOperation hours counter start value2 Bytes7.7 time (h)CWU
282Valve output 6 ({{152:Name}}) - inputReset operating hours counter1 Bit1.15 resetCWU
283Valve output 6 ({{152:Name}}) - outputValue operating hours counter2 BytesDPT.7CRTU
284Valve output 6 ({{152:Name}}) - outputOperating hours counter elapsed1 Bit1.2 booleanCRTU
320Controller 1 ({{173:Name}}) - inputBasic setpoint2 Bytes9.1 temperature (°C)CWU
320Controller 1 ({{173:Name}}) - inputSetpoint active operating mode2 Bytes9.1 temperature (°C)CWU
322Controller 1 ({{173:Name}}) - inputOperating mode switch-over1 Byte20.102 HVAC modeCWTU
322Controller 1 ({{173:Name}}) - inputComfort mode1 Bit1.1 switchCWTU
323Controller 1 ({{173:Name}}) - inputStandby mode1 Bit1.1 switchCWTU
324Controller 1 ({{173:Name}}) - inputNight operation1 Bit1.1 switchCWTU
325Controller 1 ({{173:Name}}) - inputFrost/ heat protection1 Bit1.1 switchCWTU
326Controller 1 ({{173:Name}}) - inputOperating mode forced-control1 Byte20.102 HVAC modeCWTU
327Controller 1 ({{173:Name}}) - inputPresence button1 Bit1.1 switchCWTU
327Controller 1 ({{173:Name}}) - inputPresence detector1 Bit1.1 switchCWTU
328Controller 1 ({{173:Name}}) - inputWindows status1 Bit1.19 window/doorCWU
329Controller 1 ({{173:Name}}) - inputHeating / cooling change-over1 Bit1.100 heating/coolingCWTU
329Controller 1 ({{173:Name}}) - outputHeating / cooling change-over1 Bit1.100 heating/coolingCTU
330Controller 1 ({{173:Name}}) - outputController status1 ByteCTU
330Controller 1 ({{173:Name}}) - outputKNX status operating mode1 Byte20.102 HVAC modeCTU
330Controller 1 ({{173:Name}}) - outputController status, Comfort mode1 Bit1.1 switchCTU
330Controller 1 ({{173:Name}}) - outputController status, Standby mode1 Bit1.1 switchCTU
330Controller 1 ({{173:Name}}) - outputController status, night mode1 Bit1.1 switchCTU
330Controller 1 ({{173:Name}}) - outputController status, frost/heat protection1 Bit1.1 switchCTU
330Controller 1 ({{173:Name}}) - outputController status, contr. disabled1 Bit1.1 switchCTU
330Controller 1 ({{173:Name}}) - outputController status, heating/cooling1 Bit1.1 switchCTU
330Controller 1 ({{173:Name}}) - outputController status contr. inactive1 Bit1.1 switchCTU
330Controller 1 ({{173:Name}}) - outputController status, frost alarm1 Bit1.1 switchCTU
334Controller 1 ({{173:Name}}) - outputSet temperature2 Bytes9.1 temperature (°C)CRTU
336Controller 1 ({{173:Name}}) - outputCurrent setpoint shifting1 Byte6.10 counter pulses (-128..127)CRTU
337Controller 1 ({{173:Name}}) - inputPreset setpoint shifting1 Byte6.10 counter pulses (-128..127)CWU
338Controller 1 ({{173:Name}}) - outputStatus signal addition1 ByteCTU
338Controller 1 ({{173:Name}}) - outputKNX status2 Bytes22.101 RHCC statusCTU
339Controller 1 ({{173:Name}}) - outputKNX status forced operating mode1 Byte20.102 HVAC modeCTU
340Controller 1 ({{173:Name}}) - inputOutdoor temperature2 Bytes9.1 temperature (°C)CWU
341Controller 1 ({{173:Name}}) - inputLimit of cooling setpoint temperature1 Bit1.1 switchCWU
355Controller 1 ({{173:Name}}) - inputDisable controller1 Bit1.3 enableCWU
356Controller 1 ({{173:Name}}) - inputDisable additional level1 Bit1.3 enableCWU
357Controller 1 ({{173:Name}}) - outputCommand value for heating1 Byte5.1 percentage (0..100%)CTU
357Controller 1 ({{173:Name}}) - outputCommand value heating (PWM)1 Bit1.1 switchCTU
357Controller 1 ({{173:Name}}) - outputCommand value for heating1 Bit1.1 switchCTU
357Controller 1 ({{173:Name}}) - outputCommand value heating/cooling1 Byte5.1 percentage (0..100%)CTU
357Controller 1 ({{173:Name}}) - outputCommand value heating/cooling (PWM)1 Bit1.1 switchCTU
357Controller 1 ({{173:Name}}) - outputCommand value heating/cooling1 Bit1.1 switchCTU
357Controller 1 ({{173:Name}}) - outputCommand value basic heating1 Byte5.1 percentage (0..100%)CTU
357Controller 1 ({{173:Name}}) - outputCommand value basic heating (PWM)1 Bit1.1 switchCTU
357Controller 1 ({{173:Name}}) - outputCommand value basic heating1 Bit1.1 switchCTU
357Controller 1 ({{173:Name}}) - outputCommand value basic level1 Byte5.1 percentage (0..100%)CTU
357Controller 1 ({{173:Name}}) - outputCommand value basic level (PWM)1 Bit1.1 switchCTU
357Controller 1 ({{173:Name}}) - outputCommand value basic level1 Bit1.1 switchCTU
358Controller 1 ({{173:Name}}) - outputCommand value additional heating1 Byte5.1 percentage (0..100%)CTU
358Controller 1 ({{173:Name}}) - outputCommand value additional heating (PWM)1 Bit1.1 switchCTU
358Controller 1 ({{173:Name}}) - outputCommand value additional heating1 Bit1.1 switchCTU
358Controller 1 ({{173:Name}}) - outputCommand value additional level1 Byte5.1 percentage (0..100%)CTU
358Controller 1 ({{173:Name}}) - outputCommand value additional level (PWM)1 Bit1.1 switchCTU
358Controller 1 ({{173:Name}}) - outputCommand value additional level1 Bit1.1 switchCTU
359Controller 1 ({{173:Name}}) - outputCommand value cooling1 Byte5.1 percentage (0..100%)CTU
359Controller 1 ({{173:Name}}) - outputCommand value cooling (PWM)1 Bit1.1 switchCTU
359Controller 1 ({{173:Name}}) - outputCommand value cooling1 Bit1.1 switchCTU
359Controller 1 ({{173:Name}}) - outputCommand value basic cooling1 Byte5.1 percentage (0..100%)CTU
359Controller 1 ({{173:Name}}) - outputCommand value basic cooling(PWM)1 Bit1.1 switchCTU
359Controller 1 ({{173:Name}}) - outputCommand value basic cooling1 Bit1.1 switchCTU
360Controller 1 ({{173:Name}}) - outputCommand value additional cooling1 Byte5.1 percentage (0..100%)CTU
360Controller 1 ({{173:Name}}) - outputCommand value additional cooling (PWM)1 Bit1.1 switchCTU
360Controller 1 ({{173:Name}}) - outputCommand value additional cooling1 Bit1.1 switchCTU
361Controller 1 ({{173:Name}}) - outputPWM command value heating1 Byte5.1 percentage (0..100%)CTU
361Controller 1 ({{173:Name}}) - outputPWM command value heating/cooling1 Byte5.1 percentage (0..100%)CTU
361Controller 1 ({{173:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
361Controller 1 ({{173:Name}}) - outputPWM command value basic level1 Byte5.1 percentage (0..100%)CTU
362Controller 1 ({{173:Name}}) - outputPWM command value additional heating1 Byte5.1 percentage (0..100%)CTU
362Controller 1 ({{173:Name}}) - outputPWM command value additional level1 Byte5.1 percentage (0..100%)CTU
363Controller 1 ({{173:Name}}) - outputPWM command value cooling1 Byte5.1 percentage (0..100%)CTU
363Controller 1 ({{173:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
364Controller 1 ({{173:Name}}) - outputPWM command value additional cooling1 Byte5.1 percentage (0..100%)CTU
365Controller 1 ({{173:Name}}) - inputCommand value limit1 Bit1.1 switchCWU
367Controller 1 ({{173:Name}}) - inputFloor temperature2 Bytes9.1 temperature (°C)CWU
371Controller 1 ({{173:Name}}) - outputHeating indication1 Bit1.1 switchCTU
372Controller 1 ({{173:Name}}) - outputCooling indication1 Bit1.1 switchCTU
381Controller 1 ({{173:Name}}) - outputActual-temperature2 Bytes9.1 temperature (°C)CRTU
382Controller 1 ({{173:Name}}) - inputReceived temperature 1 (temperature sensor 1)2 Bytes9.1 temperature (°C)CWTU
383Controller 1 ({{173:Name}}) - inputReceived temperature 2 (temperature sensor 2)2 Bytes9.1 temperature (°C)CWTU
391Controller 2 ({{1329:Name}}) - inputBasic setpoint2 Bytes9.1 temperature (°C)CWU
391Controller 2 ({{1329:Name}}) - inputSetpoint active operating mode2 Bytes9.1 temperature (°C)CWU
393Controller 2 ({{1329:Name}}) - inputOperating mode switch-over1 Byte20.102 HVAC modeCWTU
393Controller 2 ({{1329:Name}}) - inputComfort mode1 Bit1.1 switchCWTU
394Controller 2 ({{1329:Name}}) - inputStandby mode1 Bit1.1 switchCWTU
395Controller 2 ({{1329:Name}}) - inputNight operation1 Bit1.1 switchCWTU
396Controller 2 ({{1329:Name}}) - inputFrost/ heat protection1 Bit1.1 switchCWTU
397Controller 2 ({{1329:Name}}) - inputOperating mode forced-control1 Byte20.102 HVAC modeCWTU
398Controller 2 ({{1329:Name}}) - inputPresence button1 Bit1.1 switchCWTU
398Controller 2 ({{1329:Name}}) - inputPresence detector1 Bit1.1 switchCWTU
399Controller 2 ({{1329:Name}}) - inputWindows status1 Bit1.19 window/doorCWU
400Controller 2 ({{1329:Name}}) - inputHeating / cooling change-over1 Bit1.100 heating/coolingCWTU
400Controller 2 ({{1329:Name}}) - outputHeating / cooling change-over1 Bit1.100 heating/coolingCTU
401Controller 2 ({{1329:Name}}) - outputController status1 ByteCTU
401Controller 2 ({{1329:Name}}) - outputKNX status operating mode1 Byte20.102 HVAC modeCTU
401Controller 2 ({{1329:Name}}) - outputController status, Comfort mode1 Bit1.1 switchCTU
401Controller 2 ({{1329:Name}}) - outputController status, Standby mode1 Bit1.1 switchCTU
401Controller 2 ({{1329:Name}}) - outputController status, night mode1 Bit1.1 switchCTU
401Controller 2 ({{1329:Name}}) - outputController status, frost/heat protection1 Bit1.1 switchCTU
401Controller 2 ({{1329:Name}}) - outputController status, contr. disabled1 Bit1.1 switchCTU
401Controller 2 ({{1329:Name}}) - outputController status, heating/cooling1 Bit1.1 switchCTU
401Controller 2 ({{1329:Name}}) - outputController status contr. inactive1 Bit1.1 switchCTU
401Controller 2 ({{1329:Name}}) - outputController status, frost alarm1 Bit1.1 switchCTU
405Controller 2 ({{1329:Name}}) - outputSet temperature2 Bytes9.1 temperature (°C)CRTU
407Controller 2 ({{1329:Name}}) - outputCurrent setpoint shifting1 Byte6.10 counter pulses (-128..127)CRTU
408Controller 2 ({{1329:Name}}) - inputPreset setpoint shifting1 Byte6.10 counter pulses (-128..127)CWU
409Controller 2 ({{1329:Name}}) - outputStatus signal addition1 ByteCTU
409Controller 2 ({{1329:Name}}) - outputKNX status2 Bytes22.101 RHCC statusCTU
410Controller 2 ({{1329:Name}}) - outputKNX status forced operating mode1 Byte20.102 HVAC modeCTU
411Controller 2 ({{1329:Name}}) - inputOutdoor temperature2 Bytes9.1 temperature (°C)CWU
412Controller 2 ({{1329:Name}}) - inputLimit of cooling setpoint temperature1 Bit1.1 switchCWU
426Controller 2 ({{1329:Name}}) - inputDisable controller1 Bit1.3 enableCWU
427Controller 2 ({{1329:Name}}) - inputDisable additional level1 Bit1.3 enableCWU
428Controller 2 ({{1329:Name}}) - outputCommand value for heating1 Byte5.1 percentage (0..100%)CTU
428Controller 2 ({{1329:Name}}) - outputCommand value heating (PWM)1 Bit1.1 switchCTU
428Controller 2 ({{1329:Name}}) - outputCommand value for heating1 Bit1.1 switchCTU
428Controller 2 ({{1329:Name}}) - outputCommand value heating/cooling1 Byte5.1 percentage (0..100%)CTU
428Controller 2 ({{1329:Name}}) - outputCommand value heating/cooling (PWM)1 Bit1.1 switchCTU
428Controller 2 ({{1329:Name}}) - outputCommand value heating/cooling1 Bit1.1 switchCTU
428Controller 2 ({{1329:Name}}) - outputCommand value basic heating1 Byte5.1 percentage (0..100%)CTU
428Controller 2 ({{1329:Name}}) - outputCommand value basic heating (PWM)1 Bit1.1 switchCTU
428Controller 2 ({{1329:Name}}) - outputCommand value basic heating1 Bit1.1 switchCTU
428Controller 2 ({{1329:Name}}) - outputCommand value basic level1 Byte5.1 percentage (0..100%)CTU
428Controller 2 ({{1329:Name}}) - outputCommand value basic level (PWM)1 Bit1.1 switchCTU
428Controller 2 ({{1329:Name}}) - outputCommand value basic level1 Bit1.1 switchCTU
429Controller 2 ({{1329:Name}}) - outputCommand value additional heating1 Byte5.1 percentage (0..100%)CTU
429Controller 2 ({{1329:Name}}) - outputCommand value additional heating (PWM)1 Bit1.1 switchCTU
429Controller 2 ({{1329:Name}}) - outputCommand value additional heating1 Bit1.1 switchCTU
429Controller 2 ({{1329:Name}}) - outputCommand value additional level1 Byte5.1 percentage (0..100%)CTU
429Controller 2 ({{1329:Name}}) - outputCommand value additional level (PWM)1 Bit1.1 switchCTU
429Controller 2 ({{1329:Name}}) - outputCommand value additional level1 Bit1.1 switchCTU
430Controller 2 ({{1329:Name}}) - outputCommand value cooling1 Byte5.1 percentage (0..100%)CTU
430Controller 2 ({{1329:Name}}) - outputCommand value cooling (PWM)1 Bit1.1 switchCTU
430Controller 2 ({{1329:Name}}) - outputCommand value cooling1 Bit1.1 switchCTU
430Controller 2 ({{1329:Name}}) - outputCommand value basic cooling1 Byte5.1 percentage (0..100%)CTU
430Controller 2 ({{1329:Name}}) - outputCommand value basic cooling(PWM)1 Bit1.1 switchCTU
430Controller 2 ({{1329:Name}}) - outputCommand value basic cooling1 Bit1.1 switchCTU
431Controller 2 ({{1329:Name}}) - outputCommand value additional cooling1 Byte5.1 percentage (0..100%)CTU
431Controller 2 ({{1329:Name}}) - outputCommand value additional cooling (PWM)1 Bit1.1 switchCTU
431Controller 2 ({{1329:Name}}) - outputCommand value additional cooling1 Bit1.1 switchCTU
432Controller 2 ({{1329:Name}}) - outputPWM command value heating1 Byte5.1 percentage (0..100%)CTU
432Controller 2 ({{1329:Name}}) - outputPWM command value heating/cooling1 Byte5.1 percentage (0..100%)CTU
432Controller 2 ({{1329:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
432Controller 2 ({{1329:Name}}) - outputPWM command value basic level1 Byte5.1 percentage (0..100%)CTU
433Controller 2 ({{1329:Name}}) - outputPWM command value additional heating1 Byte5.1 percentage (0..100%)CTU
433Controller 2 ({{1329:Name}}) - outputPWM command value additional level1 Byte5.1 percentage (0..100%)CTU
434Controller 2 ({{1329:Name}}) - outputPWM command value cooling1 Byte5.1 percentage (0..100%)CTU
434Controller 2 ({{1329:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
435Controller 2 ({{1329:Name}}) - outputPWM command value additional cooling1 Byte5.1 percentage (0..100%)CTU
436Controller 2 ({{1329:Name}}) - inputCommand value limit1 Bit1.1 switchCWU
438Controller 2 ({{1329:Name}}) - inputFloor temperature2 Bytes9.1 temperature (°C)CWU
442Controller 2 ({{1329:Name}}) - outputHeating indication1 Bit1.1 switchCTU
443Controller 2 ({{1329:Name}}) - outputCooling indication1 Bit1.1 switchCTU
452Controller 2 ({{1329:Name}}) - outputActual-temperature2 Bytes9.1 temperature (°C)CRTU
453Controller 2 ({{1329:Name}}) - inputReceived temperature 1 (temperature sensor 1)2 Bytes9.1 temperature (°C)CWTU
454Controller 2 ({{1329:Name}}) - inputReceived temperature 2 (temperature sensor 2)2 Bytes9.1 temperature (°C)CWTU
462Controller 3 ({{2013:Name}}) - inputBasic setpoint2 Bytes9.1 temperature (°C)CWU
462Controller 3 ({{2013:Name}}) - inputSetpoint active operating mode2 Bytes9.1 temperature (°C)CWU
464Controller 3 ({{2013:Name}}) - inputOperating mode switch-over1 Byte20.102 HVAC modeCWTU
464Controller 3 ({{2013:Name}}) - inputComfort mode1 Bit1.1 switchCWTU
465Controller 3 ({{2013:Name}}) - inputStandby mode1 Bit1.1 switchCWTU
466Controller 3 ({{2013:Name}}) - inputNight operation1 Bit1.1 switchCWTU
467Controller 3 ({{2013:Name}}) - inputFrost/ heat protection1 Bit1.1 switchCWTU
468Controller 3 ({{2013:Name}}) - inputOperating mode forced-control1 Byte20.102 HVAC modeCWTU
469Controller 3 ({{2013:Name}}) - inputPresence button1 Bit1.1 switchCWTU
469Controller 3 ({{2013:Name}}) - inputPresence detector1 Bit1.1 switchCWTU
470Controller 3 ({{2013:Name}}) - inputWindows status1 Bit1.19 window/doorCWU
471Controller 3 ({{2013:Name}}) - inputHeating / cooling change-over1 Bit1.100 heating/coolingCWTU
471Controller 3 ({{2013:Name}}) - outputHeating / cooling change-over1 Bit1.100 heating/coolingCTU
472Controller 3 ({{2013:Name}}) - outputController status1 ByteCTU
472Controller 3 ({{2013:Name}}) - outputKNX status operating mode1 Byte20.102 HVAC modeCTU
472Controller 3 ({{2013:Name}}) - outputController status, Comfort mode1 Bit1.1 switchCTU
472Controller 3 ({{2013:Name}}) - outputController status, Standby mode1 Bit1.1 switchCTU
472Controller 3 ({{2013:Name}}) - outputController status, night mode1 Bit1.1 switchCTU
472Controller 3 ({{2013:Name}}) - outputController status, frost/heat protection1 Bit1.1 switchCTU
472Controller 3 ({{2013:Name}}) - outputController status, contr. disabled1 Bit1.1 switchCTU
472Controller 3 ({{2013:Name}}) - outputController status, heating/cooling1 Bit1.1 switchCTU
472Controller 3 ({{2013:Name}}) - outputController status contr. inactive1 Bit1.1 switchCTU
472Controller 3 ({{2013:Name}}) - outputController status, frost alarm1 Bit1.1 switchCTU
476Controller 3 ({{2013:Name}}) - outputSet temperature2 Bytes9.1 temperature (°C)CRTU
478Controller 3 ({{2013:Name}}) - outputCurrent setpoint shifting1 Byte6.10 counter pulses (-128..127)CRTU
479Controller 3 ({{2013:Name}}) - inputPreset setpoint shifting1 Byte6.10 counter pulses (-128..127)CWU
480Controller 3 ({{2013:Name}}) - outputStatus signal addition1 ByteCTU
480Controller 3 ({{2013:Name}}) - outputKNX status2 Bytes22.101 RHCC statusCTU
481Controller 3 ({{2013:Name}}) - outputKNX status forced operating mode1 Byte20.102 HVAC modeCTU
482Controller 3 ({{2013:Name}}) - inputOutdoor temperature2 Bytes9.1 temperature (°C)CWU
483Controller 3 ({{2013:Name}}) - inputLimit of cooling setpoint temperature1 Bit1.1 switchCWU
497Controller 3 ({{2013:Name}}) - inputDisable controller1 Bit1.3 enableCWU
498Controller 3 ({{2013:Name}}) - inputDisable additional level1 Bit1.3 enableCWU
499Controller 3 ({{2013:Name}}) - outputCommand value for heating1 Byte5.1 percentage (0..100%)CTU
499Controller 3 ({{2013:Name}}) - outputCommand value heating (PWM)1 Bit1.1 switchCTU
499Controller 3 ({{2013:Name}}) - outputCommand value for heating1 Bit1.1 switchCTU
499Controller 3 ({{2013:Name}}) - outputCommand value heating/cooling1 Byte5.1 percentage (0..100%)CTU
499Controller 3 ({{2013:Name}}) - outputCommand value heating/cooling (PWM)1 Bit1.1 switchCTU
499Controller 3 ({{2013:Name}}) - outputCommand value heating/cooling1 Bit1.1 switchCTU
499Controller 3 ({{2013:Name}}) - outputCommand value basic heating1 Byte5.1 percentage (0..100%)CTU
499Controller 3 ({{2013:Name}}) - outputCommand value basic heating (PWM)1 Bit1.1 switchCTU
499Controller 3 ({{2013:Name}}) - outputCommand value basic heating1 Bit1.1 switchCTU
499Controller 3 ({{2013:Name}}) - outputCommand value basic level1 Byte5.1 percentage (0..100%)CTU
499Controller 3 ({{2013:Name}}) - outputCommand value basic level (PWM)1 Bit1.1 switchCTU
499Controller 3 ({{2013:Name}}) - outputCommand value basic level1 Bit1.1 switchCTU
500Controller 3 ({{2013:Name}}) - outputCommand value additional heating1 Byte5.1 percentage (0..100%)CTU
500Controller 3 ({{2013:Name}}) - outputCommand value additional heating (PWM)1 Bit1.1 switchCTU
500Controller 3 ({{2013:Name}}) - outputCommand value additional heating1 Bit1.1 switchCTU
500Controller 3 ({{2013:Name}}) - outputCommand value additional level1 Byte5.1 percentage (0..100%)CTU
500Controller 3 ({{2013:Name}}) - outputCommand value additional level (PWM)1 Bit1.1 switchCTU
500Controller 3 ({{2013:Name}}) - outputCommand value additional level1 Bit1.1 switchCTU
501Controller 3 ({{2013:Name}}) - outputCommand value cooling1 Byte5.1 percentage (0..100%)CTU
501Controller 3 ({{2013:Name}}) - outputCommand value cooling (PWM)1 Bit1.1 switchCTU
501Controller 3 ({{2013:Name}}) - outputCommand value cooling1 Bit1.1 switchCTU
501Controller 3 ({{2013:Name}}) - outputCommand value basic cooling1 Byte5.1 percentage (0..100%)CTU
501Controller 3 ({{2013:Name}}) - outputCommand value basic cooling(PWM)1 Bit1.1 switchCTU
501Controller 3 ({{2013:Name}}) - outputCommand value basic cooling1 Bit1.1 switchCTU
502Controller 3 ({{2013:Name}}) - outputCommand value additional cooling1 Byte5.1 percentage (0..100%)CTU
502Controller 3 ({{2013:Name}}) - outputCommand value additional cooling (PWM)1 Bit1.1 switchCTU
502Controller 3 ({{2013:Name}}) - outputCommand value additional cooling1 Bit1.1 switchCTU
503Controller 3 ({{2013:Name}}) - outputPWM command value heating1 Byte5.1 percentage (0..100%)CTU
503Controller 3 ({{2013:Name}}) - outputPWM command value heating/cooling1 Byte5.1 percentage (0..100%)CTU
503Controller 3 ({{2013:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
503Controller 3 ({{2013:Name}}) - outputPWM command value basic level1 Byte5.1 percentage (0..100%)CTU
504Controller 3 ({{2013:Name}}) - outputPWM command value additional heating1 Byte5.1 percentage (0..100%)CTU
504Controller 3 ({{2013:Name}}) - outputPWM command value additional level1 Byte5.1 percentage (0..100%)CTU
505Controller 3 ({{2013:Name}}) - outputPWM command value cooling1 Byte5.1 percentage (0..100%)CTU
505Controller 3 ({{2013:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
506Controller 3 ({{2013:Name}}) - outputPWM command value additional cooling1 Byte5.1 percentage (0..100%)CTU
507Controller 3 ({{2013:Name}}) - inputCommand value limit1 Bit1.1 switchCWU
509Controller 3 ({{2013:Name}}) - inputFloor temperature2 Bytes9.1 temperature (°C)CWU
513Controller 3 ({{2013:Name}}) - outputHeating indication1 Bit1.1 switchCTU
514Controller 3 ({{2013:Name}}) - outputCooling indication1 Bit1.1 switchCTU
523Controller 3 ({{2013:Name}}) - outputActual-temperature2 Bytes9.1 temperature (°C)CRTU
524Controller 3 ({{2013:Name}}) - inputReceived temperature 1 (temperature sensor 1)2 Bytes9.1 temperature (°C)CWTU
525Controller 3 ({{2013:Name}}) - inputReceived temperature 2 (temperature sensor 2)2 Bytes9.1 temperature (°C)CWTU
533Controller 4 ({{2697:Name}}) - inputBasic setpoint2 Bytes9.1 temperature (°C)CWU
533Controller 4 ({{2697:Name}}) - inputSetpoint active operating mode2 Bytes9.1 temperature (°C)CWU
535Controller 4 ({{2697:Name}}) - inputOperating mode switch-over1 Byte20.102 HVAC modeCWTU
535Controller 4 ({{2697:Name}}) - inputComfort mode1 Bit1.1 switchCWTU
536Controller 4 ({{2697:Name}}) - inputStandby mode1 Bit1.1 switchCWTU
537Controller 4 ({{2697:Name}}) - inputNight operation1 Bit1.1 switchCWTU
538Controller 4 ({{2697:Name}}) - inputFrost/ heat protection1 Bit1.1 switchCWTU
539Controller 4 ({{2697:Name}}) - inputOperating mode forced-control1 Byte20.102 HVAC modeCWTU
540Controller 4 ({{2697:Name}}) - inputPresence button1 Bit1.1 switchCWTU
540Controller 4 ({{2697:Name}}) - inputPresence detector1 Bit1.1 switchCWTU
541Controller 4 ({{2697:Name}}) - inputWindows status1 Bit1.19 window/doorCWU
542Controller 4 ({{2697:Name}}) - inputHeating / cooling change-over1 Bit1.100 heating/coolingCWTU
542Controller 4 ({{2697:Name}}) - outputHeating / cooling change-over1 Bit1.100 heating/coolingCTU
543Controller 4 ({{2697:Name}}) - outputController status1 ByteCTU
543Controller 4 ({{2697:Name}}) - outputKNX status operating mode1 Byte20.102 HVAC modeCTU
543Controller 4 ({{2697:Name}}) - outputController status, Comfort mode1 Bit1.1 switchCTU
543Controller 4 ({{2697:Name}}) - outputController status, Standby mode1 Bit1.1 switchCTU
543Controller 4 ({{2697:Name}}) - outputController status, night mode1 Bit1.1 switchCTU
543Controller 4 ({{2697:Name}}) - outputController status, frost/heat protection1 Bit1.1 switchCTU
543Controller 4 ({{2697:Name}}) - outputController status, contr. disabled1 Bit1.1 switchCTU
543Controller 4 ({{2697:Name}}) - outputController status, heating/cooling1 Bit1.1 switchCTU
543Controller 4 ({{2697:Name}}) - outputController status contr. inactive1 Bit1.1 switchCTU
543Controller 4 ({{2697:Name}}) - outputController status, frost alarm1 Bit1.1 switchCTU
547Controller 4 ({{2697:Name}}) - outputSet temperature2 Bytes9.1 temperature (°C)CRTU
549Controller 4 ({{2697:Name}}) - outputCurrent setpoint shifting1 Byte6.10 counter pulses (-128..127)CRTU
550Controller 4 ({{2697:Name}}) - inputPreset setpoint shifting1 Byte6.10 counter pulses (-128..127)CWU
551Controller 4 ({{2697:Name}}) - outputStatus signal addition1 ByteCTU
551Controller 4 ({{2697:Name}}) - outputKNX status2 Bytes22.101 RHCC statusCTU
552Controller 4 ({{2697:Name}}) - outputKNX status forced operating mode1 Byte20.102 HVAC modeCTU
553Controller 4 ({{2697:Name}}) - inputOutdoor temperature2 Bytes9.1 temperature (°C)CWU
554Controller 4 ({{2697:Name}}) - inputLimit of cooling setpoint temperature1 Bit1.1 switchCWU
568Controller 4 ({{2697:Name}}) - inputDisable controller1 Bit1.3 enableCWU
569Controller 4 ({{2697:Name}}) - inputDisable additional level1 Bit1.3 enableCWU
570Controller 4 ({{2697:Name}}) - outputCommand value for heating1 Byte5.1 percentage (0..100%)CTU
570Controller 4 ({{2697:Name}}) - outputCommand value heating (PWM)1 Bit1.1 switchCTU
570Controller 4 ({{2697:Name}}) - outputCommand value for heating1 Bit1.1 switchCTU
570Controller 4 ({{2697:Name}}) - outputCommand value heating/cooling1 Byte5.1 percentage (0..100%)CTU
570Controller 4 ({{2697:Name}}) - outputCommand value heating/cooling (PWM)1 Bit1.1 switchCTU
570Controller 4 ({{2697:Name}}) - outputCommand value heating/cooling1 Bit1.1 switchCTU
570Controller 4 ({{2697:Name}}) - outputCommand value basic heating1 Byte5.1 percentage (0..100%)CTU
570Controller 4 ({{2697:Name}}) - outputCommand value basic heating (PWM)1 Bit1.1 switchCTU
570Controller 4 ({{2697:Name}}) - outputCommand value basic heating1 Bit1.1 switchCTU
570Controller 4 ({{2697:Name}}) - outputCommand value basic level1 Byte5.1 percentage (0..100%)CTU
570Controller 4 ({{2697:Name}}) - outputCommand value basic level (PWM)1 Bit1.1 switchCTU
570Controller 4 ({{2697:Name}}) - outputCommand value basic level1 Bit1.1 switchCTU
571Controller 4 ({{2697:Name}}) - outputCommand value additional heating1 Byte5.1 percentage (0..100%)CTU
571Controller 4 ({{2697:Name}}) - outputCommand value additional heating (PWM)1 Bit1.1 switchCTU
571Controller 4 ({{2697:Name}}) - outputCommand value additional heating1 Bit1.1 switchCTU
571Controller 4 ({{2697:Name}}) - outputCommand value additional level1 Byte5.1 percentage (0..100%)CTU
571Controller 4 ({{2697:Name}}) - outputCommand value additional level (PWM)1 Bit1.1 switchCTU
571Controller 4 ({{2697:Name}}) - outputCommand value additional level1 Bit1.1 switchCTU
572Controller 4 ({{2697:Name}}) - outputCommand value cooling1 Byte5.1 percentage (0..100%)CTU
572Controller 4 ({{2697:Name}}) - outputCommand value cooling (PWM)1 Bit1.1 switchCTU
572Controller 4 ({{2697:Name}}) - outputCommand value cooling1 Bit1.1 switchCTU
572Controller 4 ({{2697:Name}}) - outputCommand value basic cooling1 Byte5.1 percentage (0..100%)CTU
572Controller 4 ({{2697:Name}}) - outputCommand value basic cooling(PWM)1 Bit1.1 switchCTU
572Controller 4 ({{2697:Name}}) - outputCommand value basic cooling1 Bit1.1 switchCTU
573Controller 4 ({{2697:Name}}) - outputCommand value additional cooling1 Byte5.1 percentage (0..100%)CTU
573Controller 4 ({{2697:Name}}) - outputCommand value additional cooling (PWM)1 Bit1.1 switchCTU
573Controller 4 ({{2697:Name}}) - outputCommand value additional cooling1 Bit1.1 switchCTU
574Controller 4 ({{2697:Name}}) - outputPWM command value heating1 Byte5.1 percentage (0..100%)CTU
574Controller 4 ({{2697:Name}}) - outputPWM command value heating/cooling1 Byte5.1 percentage (0..100%)CTU
574Controller 4 ({{2697:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
574Controller 4 ({{2697:Name}}) - outputPWM command value basic level1 Byte5.1 percentage (0..100%)CTU
575Controller 4 ({{2697:Name}}) - outputPWM command value additional heating1 Byte5.1 percentage (0..100%)CTU
575Controller 4 ({{2697:Name}}) - outputPWM command value additional level1 Byte5.1 percentage (0..100%)CTU
576Controller 4 ({{2697:Name}}) - outputPWM command value cooling1 Byte5.1 percentage (0..100%)CTU
576Controller 4 ({{2697:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
577Controller 4 ({{2697:Name}}) - outputPWM command value additional cooling1 Byte5.1 percentage (0..100%)CTU
578Controller 4 ({{2697:Name}}) - inputCommand value limit1 Bit1.1 switchCWU
580Controller 4 ({{2697:Name}}) - inputFloor temperature2 Bytes9.1 temperature (°C)CWU
584Controller 4 ({{2697:Name}}) - outputHeating indication1 Bit1.1 switchCTU
585Controller 4 ({{2697:Name}}) - outputCooling indication1 Bit1.1 switchCTU
594Controller 4 ({{2697:Name}}) - outputActual-temperature2 Bytes9.1 temperature (°C)CRTU
595Controller 4 ({{2697:Name}}) - inputReceived temperature 1 (temperature sensor 1)2 Bytes9.1 temperature (°C)CWTU
596Controller 4 ({{2697:Name}}) - inputReceived temperature 2 (temperature sensor 2)2 Bytes9.1 temperature (°C)CWTU
604Controller 5 ({{3381:Name}}) - inputBasic setpoint2 Bytes9.1 temperature (°C)CWU
604Controller 5 ({{3381:Name}}) - inputSetpoint active operating mode2 Bytes9.1 temperature (°C)CWU
606Controller 5 ({{3381:Name}}) - inputOperating mode switch-over1 Byte20.102 HVAC modeCWTU
606Controller 5 ({{3381:Name}}) - inputComfort mode1 Bit1.1 switchCWTU
607Controller 5 ({{3381:Name}}) - inputStandby mode1 Bit1.1 switchCWTU
608Controller 5 ({{3381:Name}}) - inputNight operation1 Bit1.1 switchCWTU
609Controller 5 ({{3381:Name}}) - inputFrost/ heat protection1 Bit1.1 switchCWTU
610Controller 5 ({{3381:Name}}) - inputOperating mode forced-control1 Byte20.102 HVAC modeCWTU
611Controller 5 ({{3381:Name}}) - inputPresence button1 Bit1.1 switchCWTU
611Controller 5 ({{3381:Name}}) - inputPresence detector1 Bit1.1 switchCWTU
612Controller 5 ({{3381:Name}}) - inputWindows status1 Bit1.19 window/doorCWU
613Controller 5 ({{3381:Name}}) - inputHeating / cooling change-over1 Bit1.100 heating/coolingCWTU
613Controller 5 ({{3381:Name}}) - outputHeating / cooling change-over1 Bit1.100 heating/coolingCTU
614Controller 5 ({{3381:Name}}) - outputController status1 ByteCTU
614Controller 5 ({{3381:Name}}) - outputKNX status operating mode1 Byte20.102 HVAC modeCTU
614Controller 5 ({{3381:Name}}) - outputController status, Comfort mode1 Bit1.1 switchCTU
614Controller 5 ({{3381:Name}}) - outputController status, Standby mode1 Bit1.1 switchCTU
614Controller 5 ({{3381:Name}}) - outputController status, night mode1 Bit1.1 switchCTU
614Controller 5 ({{3381:Name}}) - outputController status, frost/heat protection1 Bit1.1 switchCTU
614Controller 5 ({{3381:Name}}) - outputController status, contr. disabled1 Bit1.1 switchCTU
614Controller 5 ({{3381:Name}}) - outputController status, heating/cooling1 Bit1.1 switchCTU
614Controller 5 ({{3381:Name}}) - outputController status contr. inactive1 Bit1.1 switchCTU
614Controller 5 ({{3381:Name}}) - outputController status, frost alarm1 Bit1.1 switchCTU
618Controller 5 ({{3381:Name}}) - outputSet temperature2 Bytes9.1 temperature (°C)CRTU
620Controller 5 ({{3381:Name}}) - outputCurrent setpoint shifting1 Byte6.10 counter pulses (-128..127)CRTU
621Controller 5 ({{3381:Name}}) - inputPreset setpoint shifting1 Byte6.10 counter pulses (-128..127)CWU
622Controller 5 ({{3381:Name}}) - outputStatus signal addition1 ByteCTU
622Controller 5 ({{3381:Name}}) - outputKNX status2 Bytes22.101 RHCC statusCTU
623Controller 5 ({{3381:Name}}) - outputKNX status forced operating mode1 Byte20.102 HVAC modeCTU
624Controller 5 ({{3381:Name}}) - inputOutdoor temperature2 Bytes9.1 temperature (°C)CWU
625Controller 5 ({{3381:Name}}) - inputLimit of cooling setpoint temperature1 Bit1.1 switchCWU
639Controller 5 ({{3381:Name}}) - inputDisable controller1 Bit1.3 enableCWU
640Controller 5 ({{3381:Name}}) - inputDisable additional level1 Bit1.3 enableCWU
641Controller 5 ({{3381:Name}}) - outputCommand value for heating1 Byte5.1 percentage (0..100%)CTU
641Controller 5 ({{3381:Name}}) - outputCommand value heating (PWM)1 Bit1.1 switchCTU
641Controller 5 ({{3381:Name}}) - outputCommand value for heating1 Bit1.1 switchCTU
641Controller 5 ({{3381:Name}}) - outputCommand value heating/cooling1 Byte5.1 percentage (0..100%)CTU
641Controller 5 ({{3381:Name}}) - outputCommand value heating/cooling (PWM)1 Bit1.1 switchCTU
641Controller 5 ({{3381:Name}}) - outputCommand value heating/cooling1 Bit1.1 switchCTU
641Controller 5 ({{3381:Name}}) - outputCommand value basic heating1 Byte5.1 percentage (0..100%)CTU
641Controller 5 ({{3381:Name}}) - outputCommand value basic heating (PWM)1 Bit1.1 switchCTU
641Controller 5 ({{3381:Name}}) - outputCommand value basic heating1 Bit1.1 switchCTU
641Controller 5 ({{3381:Name}}) - outputCommand value basic level1 Byte5.1 percentage (0..100%)CTU
641Controller 5 ({{3381:Name}}) - outputCommand value basic level (PWM)1 Bit1.1 switchCTU
641Controller 5 ({{3381:Name}}) - outputCommand value basic level1 Bit1.1 switchCTU
642Controller 5 ({{3381:Name}}) - outputCommand value additional heating1 Byte5.1 percentage (0..100%)CTU
642Controller 5 ({{3381:Name}}) - outputCommand value additional heating (PWM)1 Bit1.1 switchCTU
642Controller 5 ({{3381:Name}}) - outputCommand value additional heating1 Bit1.1 switchCTU
642Controller 5 ({{3381:Name}}) - outputCommand value additional level1 Byte5.1 percentage (0..100%)CTU
642Controller 5 ({{3381:Name}}) - outputCommand value additional level (PWM)1 Bit1.1 switchCTU
642Controller 5 ({{3381:Name}}) - outputCommand value additional level1 Bit1.1 switchCTU
643Controller 5 ({{3381:Name}}) - outputCommand value cooling1 Byte5.1 percentage (0..100%)CTU
643Controller 5 ({{3381:Name}}) - outputCommand value cooling (PWM)1 Bit1.1 switchCTU
643Controller 5 ({{3381:Name}}) - outputCommand value cooling1 Bit1.1 switchCTU
643Controller 5 ({{3381:Name}}) - outputCommand value basic cooling1 Byte5.1 percentage (0..100%)CTU
643Controller 5 ({{3381:Name}}) - outputCommand value basic cooling(PWM)1 Bit1.1 switchCTU
643Controller 5 ({{3381:Name}}) - outputCommand value basic cooling1 Bit1.1 switchCTU
644Controller 5 ({{3381:Name}}) - outputCommand value additional cooling1 Byte5.1 percentage (0..100%)CTU
644Controller 5 ({{3381:Name}}) - outputCommand value additional cooling (PWM)1 Bit1.1 switchCTU
644Controller 5 ({{3381:Name}}) - outputCommand value additional cooling1 Bit1.1 switchCTU
645Controller 5 ({{3381:Name}}) - outputPWM command value heating1 Byte5.1 percentage (0..100%)CTU
645Controller 5 ({{3381:Name}}) - outputPWM command value heating/cooling1 Byte5.1 percentage (0..100%)CTU
645Controller 5 ({{3381:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
645Controller 5 ({{3381:Name}}) - outputPWM command value basic level1 Byte5.1 percentage (0..100%)CTU
646Controller 5 ({{3381:Name}}) - outputPWM command value additional heating1 Byte5.1 percentage (0..100%)CTU
646Controller 5 ({{3381:Name}}) - outputPWM command value additional level1 Byte5.1 percentage (0..100%)CTU
647Controller 5 ({{3381:Name}}) - outputPWM command value cooling1 Byte5.1 percentage (0..100%)CTU
647Controller 5 ({{3381:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
648Controller 5 ({{3381:Name}}) - outputPWM command value additional cooling1 Byte5.1 percentage (0..100%)CTU
649Controller 5 ({{3381:Name}}) - inputCommand value limit1 Bit1.1 switchCWU
651Controller 5 ({{3381:Name}}) - inputFloor temperature2 Bytes9.1 temperature (°C)CWU
655Controller 5 ({{3381:Name}}) - outputHeating indication1 Bit1.1 switchCTU
656Controller 5 ({{3381:Name}}) - outputCooling indication1 Bit1.1 switchCTU
665Controller 5 ({{3381:Name}}) - outputActual-temperature2 Bytes9.1 temperature (°C)CRTU
666Controller 5 ({{3381:Name}}) - inputReceived temperature 1 (temperature sensor 1)2 Bytes9.1 temperature (°C)CWTU
667Controller 5 ({{3381:Name}}) - inputReceived temperature 2 (temperature sensor 2)2 Bytes9.1 temperature (°C)CWTU
675Controller 6 ({{4065:Name}}) - inputBasic setpoint2 Bytes9.1 temperature (°C)CWU
675Controller 6 ({{4065:Name}}) - inputSetpoint active operating mode2 Bytes9.1 temperature (°C)CWU
677Controller 6 ({{4065:Name}}) - inputOperating mode switch-over1 Byte20.102 HVAC modeCWTU
677Controller 6 ({{4065:Name}}) - inputComfort mode1 Bit1.1 switchCWTU
678Controller 6 ({{4065:Name}}) - inputStandby mode1 Bit1.1 switchCWTU
679Controller 6 ({{4065:Name}}) - inputNight operation1 Bit1.1 switchCWTU
680Controller 6 ({{4065:Name}}) - inputFrost/ heat protection1 Bit1.1 switchCWTU
681Controller 6 ({{4065:Name}}) - inputOperating mode forced-control1 Byte20.102 HVAC modeCWTU
682Controller 6 ({{4065:Name}}) - inputPresence button1 Bit1.1 switchCWTU
682Controller 6 ({{4065:Name}}) - inputPresence detector1 Bit1.1 switchCWTU
683Controller 6 ({{4065:Name}}) - inputWindows status1 Bit1.19 window/doorCWU
684Controller 6 ({{4065:Name}}) - inputHeating / cooling change-over1 Bit1.100 heating/coolingCWTU
684Controller 6 ({{4065:Name}}) - outputHeating / cooling change-over1 Bit1.100 heating/coolingCTU
685Controller 6 ({{4065:Name}}) - outputController status1 ByteCTU
685Controller 6 ({{4065:Name}}) - outputKNX status operating mode1 Byte20.102 HVAC modeCTU
685Controller 6 ({{4065:Name}}) - outputController status, Comfort mode1 Bit1.1 switchCTU
685Controller 6 ({{4065:Name}}) - outputController status, Standby mode1 Bit1.1 switchCTU
685Controller 6 ({{4065:Name}}) - outputController status, night mode1 Bit1.1 switchCTU
685Controller 6 ({{4065:Name}}) - outputController status, frost/heat protection1 Bit1.1 switchCTU
685Controller 6 ({{4065:Name}}) - outputController status, contr. disabled1 Bit1.1 switchCTU
685Controller 6 ({{4065:Name}}) - outputController status, heating/cooling1 Bit1.1 switchCTU
685Controller 6 ({{4065:Name}}) - outputController status contr. inactive1 Bit1.1 switchCTU
685Controller 6 ({{4065:Name}}) - outputController status, frost alarm1 Bit1.1 switchCTU
689Controller 6 ({{4065:Name}}) - outputSet temperature2 Bytes9.1 temperature (°C)CRTU
691Controller 6 ({{4065:Name}}) - outputCurrent setpoint shifting1 Byte6.10 counter pulses (-128..127)CRTU
692Controller 6 ({{4065:Name}}) - inputPreset setpoint shifting1 Byte6.10 counter pulses (-128..127)CWU
693Controller 6 ({{4065:Name}}) - outputStatus signal addition1 ByteCTU
693Controller 6 ({{4065:Name}}) - outputKNX status2 Bytes22.101 RHCC statusCTU
694Controller 6 ({{4065:Name}}) - outputKNX status forced operating mode1 Byte20.102 HVAC modeCTU
695Controller 6 ({{4065:Name}}) - inputOutdoor temperature2 Bytes9.1 temperature (°C)CWU
696Controller 6 ({{4065:Name}}) - inputLimit of cooling setpoint temperature1 Bit1.1 switchCWU
710Controller 6 ({{4065:Name}}) - inputDisable controller1 Bit1.3 enableCWU
711Controller 6 ({{4065:Name}}) - inputDisable additional level1 Bit1.3 enableCWU
712Controller 6 ({{4065:Name}}) - outputCommand value for heating1 Byte5.1 percentage (0..100%)CTU
712Controller 6 ({{4065:Name}}) - outputCommand value heating (PWM)1 Bit1.1 switchCTU
712Controller 6 ({{4065:Name}}) - outputCommand value for heating1 Bit1.1 switchCTU
712Controller 6 ({{4065:Name}}) - outputCommand value heating/cooling1 Byte5.1 percentage (0..100%)CTU
712Controller 6 ({{4065:Name}}) - outputCommand value heating/cooling (PWM)1 Bit1.1 switchCTU
712Controller 6 ({{4065:Name}}) - outputCommand value heating/cooling1 Bit1.1 switchCTU
712Controller 6 ({{4065:Name}}) - outputCommand value basic heating1 Byte5.1 percentage (0..100%)CTU
712Controller 6 ({{4065:Name}}) - outputCommand value basic heating (PWM)1 Bit1.1 switchCTU
712Controller 6 ({{4065:Name}}) - outputCommand value basic heating1 Bit1.1 switchCTU
712Controller 6 ({{4065:Name}}) - outputCommand value basic level1 Byte5.1 percentage (0..100%)CTU
712Controller 6 ({{4065:Name}}) - outputCommand value basic level (PWM)1 Bit1.1 switchCTU
712Controller 6 ({{4065:Name}}) - outputCommand value basic level1 Bit1.1 switchCTU
713Controller 6 ({{4065:Name}}) - outputCommand value additional heating1 Byte5.1 percentage (0..100%)CTU
713Controller 6 ({{4065:Name}}) - outputCommand value additional heating (PWM)1 Bit1.1 switchCTU
713Controller 6 ({{4065:Name}}) - outputCommand value additional heating1 Bit1.1 switchCTU
713Controller 6 ({{4065:Name}}) - outputCommand value additional level1 Byte5.1 percentage (0..100%)CTU
713Controller 6 ({{4065:Name}}) - outputCommand value additional level (PWM)1 Bit1.1 switchCTU
713Controller 6 ({{4065:Name}}) - outputCommand value additional level1 Bit1.1 switchCTU
714Controller 6 ({{4065:Name}}) - outputCommand value cooling1 Byte5.1 percentage (0..100%)CTU
714Controller 6 ({{4065:Name}}) - outputCommand value cooling (PWM)1 Bit1.1 switchCTU
714Controller 6 ({{4065:Name}}) - outputCommand value cooling1 Bit1.1 switchCTU
714Controller 6 ({{4065:Name}}) - outputCommand value basic cooling1 Byte5.1 percentage (0..100%)CTU
714Controller 6 ({{4065:Name}}) - outputCommand value basic cooling(PWM)1 Bit1.1 switchCTU
714Controller 6 ({{4065:Name}}) - outputCommand value basic cooling1 Bit1.1 switchCTU
715Controller 6 ({{4065:Name}}) - outputCommand value additional cooling1 Byte5.1 percentage (0..100%)CTU
715Controller 6 ({{4065:Name}}) - outputCommand value additional cooling (PWM)1 Bit1.1 switchCTU
715Controller 6 ({{4065:Name}}) - outputCommand value additional cooling1 Bit1.1 switchCTU
716Controller 6 ({{4065:Name}}) - outputPWM command value heating1 Byte5.1 percentage (0..100%)CTU
716Controller 6 ({{4065:Name}}) - outputPWM command value heating/cooling1 Byte5.1 percentage (0..100%)CTU
716Controller 6 ({{4065:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
716Controller 6 ({{4065:Name}}) - outputPWM command value basic level1 Byte5.1 percentage (0..100%)CTU
717Controller 6 ({{4065:Name}}) - outputPWM command value additional heating1 Byte5.1 percentage (0..100%)CTU
717Controller 6 ({{4065:Name}}) - outputPWM command value additional level1 Byte5.1 percentage (0..100%)CTU
718Controller 6 ({{4065:Name}}) - outputPWM command value cooling1 Byte5.1 percentage (0..100%)CTU
718Controller 6 ({{4065:Name}}) - outputPWM command value basic heating1 Byte5.1 percentage (0..100%)CTU
719Controller 6 ({{4065:Name}}) - outputPWM command value additional cooling1 Byte5.1 percentage (0..100%)CTU
720Controller 6 ({{4065:Name}}) - inputCommand value limit1 Bit1.1 switchCWU
722Controller 6 ({{4065:Name}}) - inputFloor temperature2 Bytes9.1 temperature (°C)CWU
726Controller 6 ({{4065:Name}}) - outputHeating indication1 Bit1.1 switchCTU
727Controller 6 ({{4065:Name}}) - outputCooling indication1 Bit1.1 switchCTU
736Controller 6 ({{4065:Name}}) - outputActual-temperature2 Bytes9.1 temperature (°C)CRTU
737Controller 6 ({{4065:Name}}) - inputReceived temperature 1 (temperature sensor 1)2 Bytes9.1 temperature (°C)CWTU
738Controller 6 ({{4065:Name}}) - inputReceived temperature 2 (temperature sensor 2)2 Bytes9.1 temperature (°C)CWTU
Parameters (371)
ParameterTypeDefault
Setting the parameters of the valve outputslisteach output individual
Delay after bus voltage return minutes (0...59)unsignedInt 0…590
seconds (0...59)unsignedInt 0…5917
Manual control in case of bus voltage failurelistenabled
Manual control during bus operationlistenabled
Polarity of disable objectlist0 = enabled; 1 = disabled
Disabling function ?listno
Transmit status ?listno
Function and polarity Status objectlist0 = inactive; 1 = Manual operation active
Behaviour at the end of permanent manual control during bus operationlistno change
Behaviour of the manual operation on bus voltage returnlistdo not exit manual operation
Disable bus control of individual outputs during bus operation?listno
Cycle time during manual operationlist20 minutes (recommended)
PWM in manual operation (5...100 %)unsignedInt 5…10050
Time for cycl. transmission of the feedback telegrams hours (0...23)unsignedInt 0…230
minutes (0...59)unsignedInt 0…592
seconds (10...59)unsignedInt 10…5910
Time for cycl. transm. of operating hours hours (0...23)unsignedInt 0…2323
minutes (0...59)unsignedInt 0…590
Switchover of Summer/winter mode ?listno
Object polarity "Summer / Winter switch-over"list1 = Winter / 0 = Summer
Operating mode after ETS programminglistno change (saved operating mode)
Global reset of all messages "short-circuit / overload" ?listno
Report operating voltage failure of the valves ?listno
Object polarity "Energy saving mode"list0 = deactivate; 1 = activate
Behaviour after bus voltage returnliststate as before bus voltage failure
Valve rinsing after deactivation of energy saving mode ?listno
Switch on pump after deactivation of energy saving mode?listno
Type of centralised feedbacklistactive signalling object
Collect. feedbk status of value outputs (opened / closed) ?listno
Time delay for feedback telegram after bus voltage return?listno
Cyclical transmission of the feedback ?listno
Object polarity "Failure of operating voltage"list0 = Voltage present / 1 = Voltage failed
Send feedback after bus voltage return ?listno
Time delay for feedback telegram after bus voltage return?listno
Object polarity "Heat requirement"list0 = no heat requirement / 1 = heat requirement
Activate function "Heat requirement" ?listno
Record external heat requirement ?listno
Limiting value minimum command value for heating requirement (0...100 %)unsignedInt 0…1000
Hysteresis for minimum command value (1...20 %)unsignedInt 1…2010
Delay heat requirement ACTIVE hours (0...23)unsignedInt 0…230
minutes (0...59)unsignedInt 0…595
seconds (0...59)unsignedInt 0…590
Delay heat requirement INACTIVE hours (0...23)unsignedInt 0…230
Activate Function "Largest command value" ?listno
Transmission of the largest command valuelistonly on change
Record external largest command value ?listno
ActivateFunction "Pump control" ?listno
Object polarity "Pump control"list0 = Switch off pump / 1 = Switch on pump
Limiting value minimum command value for pump (0...100 %)unsignedInt 0…1000
Hysteresis for minimum command value (1...20 %)unsignedInt 1…201
minutes (0...59)unsignedInt 0…5910
Delay pump INACTIVE hours (0...23)unsignedInt 0…230
seconds (0...59)unsignedInt 0…5910
Delay pump ACTIVE minutes (0...59)unsignedInt 0…590
Activate anti-sticking protection ?listno
Time for cyclical switching on of the pump (1...26 weeks)unsignedInt 1…261
Switch-on time of the pump (1...15 minutes)unsignedInt 1…155
Record external pump control ?listno
Valve in voltage-free state( Valve direction of action)listclosed
Use function "Valve rinsing" ?listno
Valve rinsing externally controllable ?listno
Object polarity "Valve rinsing Start / Stop"list 0 = Stop / 1 = Start
Activate cyclical valve rinsing?listyes
Cycle time (1...26 weeks)unsignedInt 1…261
Length of the valve rinsing (1...59 minutes)unsignedInt 1…595
Use intelligent valve rinsing ?listno
Limiting value min. command value (10...100 %)unsignedInt 10…10050
Data format of the command value inputlistconstantly (1 byte) with pulse width modulation (PWM)
Limiting value of the command value for opening the valve (1...100 %)unsignedInt 1…10010
Hysteresis limiting value for closing the valve (1...10 %)unsignedInt 1…105
Cycle time for continuous command value on the valve outputlist20 minutes
Activate command value monitoring ?listno
Monitoring time minutes (0...59)unsignedInt 0…5910
Object polarity "Command value fault"list0 = No fault / 1 = Fault.
Cyclic transmission in case of faulty command value ?listno
Send on change bylist3%
Use command value limit ?listno
Activation of the command value limitlistby object "command value limit"
Activate command value limit after bus voltage return ?listno
Activate command value limit after ETS programming?listno
Minimum command valuelist0%
Maximum command valuelist100%
Cmd value if active emergency operation summerlist30%
Cmd value if active emergency operation winterlist70%
Command value if active forced position summerlist30%
Command value if active forced position winterlist70%
Use object for the forced position ?listno
Object polarity "Forced position"list0 = no forced pos / 1 = forced pos active
Response to bus voltage failurelistactivating command as for emergency operation
Behaviour after bus or mains voltage returnlistspecify command value
Behaviour after ETS programminglistspecify command value
Type of feedbacklistactive signalling object
Feed back valve command value ?listno
Feed back combined valve status ?listno
Type of combined status feedbacklistactive signalling object
Assignment to the function "Pump control" ?listyes
Assignment to the function "Heating requirement" ?listyes
Assignment to the function "Largest command value" ?listno
Use operating hours counter ?listno
Command value in case of bus voltage failurelist0%
Command value after bus or mains voltage returnlist0%
Command value after ETS programminglist0%
Type of counterlistup-counter
Limiting value specification ?listno
Start value preset ?listno
Start value (1...65535 h)unsignedInt 1…6553565535
Limiting value (1...65535 h)unsignedInt 1…6553565535
Automatic transmission of the counting valuelistafter change by interval value
Counting value interval (1…65535 h)unsignedInt 1…655351
Signalling short-circuit / overload ?listno
Object polarity "Short-circ / overload"list0 = no short-cir, overld. / 1 = short-cir, overld.
Command value if active emergency operationlist30%
Command value if active forced positionlist30%
Cyclical transmission of the feedback if no voltage present ?listno
Behaviour at the end of the service modelisttrack states
Assignment to the service mode ?listyes
Use service mode ?listno
Name of valve channel 1text
Name of valve channel 2text
Name of valve channel 3text
Name of valve channel 4text
Name of valve channel 5text
Name of valve channel 6text
Name of controllertext
Operating modelistheating
Heating / cooling mode after a resetlistheating
Type of heating controllistcontinuous PI control
Type of heatinglisthot water heater (5 K / 150 min)
Proportional range heatingunsignedInt 10…12740
Reset time heating minutes (0 = inactive)unsignedInt 0…255240
Lower hysteresis limit of 2-point controller heatingsignedInt -128…-5-5
Upper hysteresis limit of 2-point controller heatingsignedInt 5…1275
Additional stage inhibit objectlistno
Type of cooling controllistcontinuous PI control
Type of coolinglistcooling ceiling (5 K / 240 min)
Proportional range coolingunsignedInt 10…12740
Reset time cooling minutes (0 = inactive)unsignedInt 0…255240
Lower hysteresis limit of 2-point controller coolingsignedInt -128…-5-5
Upper hysteresis limit of 2-point controller coolingsignedInt 5…1275
Transmit heating and cooling command value to shared objectlistno
Type of controllistcontinuous PI control
Type of basic level coolinglistcontinuous PI control
Type of basic level heatinglistcontinuous PI control
Type of basic heatinglisthot water heater (5 K / 150 min)
Proportional range basic levelunsignedInt 10…12740
Reset time basic level minutes (0 = inactive)unsignedInt 0…255240
Lower hysteresis limit of 2-point controller basic heatingsignedInt -128…-5-5
Upper hysteresis limit of 2-point contoller basic heatingsignedInt 5…1275
Type of additional level heatinglistcontinuous PI control
Type of additional heatinglisthot water heater (5 K / 150 min)
Proportional range heatingunsignedInt 10…12750
Reset time heating minutes (0 = inactive)unsignedInt 0…255150
Lower hysteresis limit of 2-point controller additional heatingsignedInt -128…-5-5
Upper hysteresis limit of 2-point controller additional heatingsignedInt 5…1275
Type of basic coolinglistcooling ceiling (5 K / 240 min)
Lower hysteresis limit of the 2-point controller basic coolingsignedInt -128…-5-5
Upper hysteresis limit of 2-point controller basic coolingsignedInt 5…1275
Type of additional level coolinglistcontinuous PI control
Type of additional coolinglistcooling ceiling (5 K / 240 min)
Proportional range additional levelunsignedInt 10…12740
Reset time additional level minutes (0 = inactive)unsignedInt 0…255240
Lower hysteresis limit of 2-point controller additional coolingsignedInt -128…-5-5
Upper hysteresis limit of 2-point controller additional coolingsignedInt 5…1275
Type of control basic levellistcontinuous PI control
Type of control additional levellistcontinuous PI control
Operating mode switch-overlistvia value (1 byte)
Operating mode after resetliststandby mode
Setpoint presettinglistrelative (setpoint temperatures from basic setpoint)
Change-over between heating and coolinglistautomatic
Cyclical transmission heating/cooling change-over minutes (0=inactive)unsignedInt 0…2550
Frost/heat protectionlistvia window status
Window status delay minutes (0 = inactive)unsignedInt 0…2550
Automatic frost protection temperature droplistOFF
Frost protection period in autom. mode (1...255) * 1 minunsignedInt 1…25520
Temperature detection of room temperature controller throughlistexternal temperature value 1
Calibration temperature value 1signedInt -128…1270
Request time temperature value minutes (0 = inactive)unsignedInt 0…2550
Calibration temperature value 2signedInt -128…1270
Measured value formation temperature value 1 to temperature value 2list50% to 50%
Request time temperature values minutes (0 = inactive)unsignedInt 0…2550
Transmission on room temp. change by (0 = inactive)unsignedInt 0…2553
Cyclical transmission of room temperature minutes (0 = inactive)unsignedInt 0…25515
Overwrite setpoints in device after ETS programming operation?listyes
Basic temperature after resetfloat 7…4021
Permanently apply change to basic setpoint shiftlistno
Changing the setpoint of the basic temperaturelistapprove via bus
Permanently apply change to basic temperature setpoint?listno
Dead band positionlistasymmetrical
Dead band between heating and coolingunsignedInt 0…25520
Upward adjustment of the basic setpoint temperaturelist+ 8 K
Downward adjustment of the basic setpoint temperaturelist- 8 K
Lower the setpoint temperature during standby operation (heating)signedInt -128…0-20
Lower the setpoint temperature during night operation (heating)signedInt -128…0-40
Raise the setpoint temperature during standby operation (cooling)signedInt 0…12720
Raise the setpoint temperature during night operation (cooling)signedInt 0…12740
Setpoint temperature comfort mode (heating)float 7…4021
Setpoint temperature standby mode (heating)float 7…4019
Setpoint temperature night mode (heating)float 7…4017
Setpoint temperature comfort mode (cooling)float 7…4021
Setpoint temperature standby mode (cooling)float 7…4023
Setpoint temperature night mode (cooling)float 7…4025
Accept modification of the setpoint permanently?listno
Level spacing from basic level to additional levelunsignedInt 0…25520
Step width of the setpoint shiftlist0.5 K
Frost protection setpoint temperaturefloat 7…407
Heat protection setpoint temperaturefloat 7…4535
Transmission at setpoint temp. change byunsignedInt 0…2551
Cyclical transmission of setpoint temperature minutes (0 = inactive)unsignedInt 0…2550
Setpoint temperature limit in cooling operationlistno limit
Activation of the setpoint temperature limit in cooling operation via object?listno
Difference to outdoor temperature in cooling operationunsignedInt 1…156
Max. setpoint temperature in cooling operationlist+ 26 °C
Automatic transmission on change by (0 = inactive)unsignedInt 0…1003
Cycle time of the switching command value minutesunsignedInt 1…25515
Cycle time for automatic transmission minutes (0 = inactive)unsignedInt 0…25510
Output of the command value heatinglistnormal (under current, this means opened)
Output of the command value coolinglistnormal (under current, this means opened)
Output of the command valuelistnormal (under current, this means opened)
Output of the command value basic level heatinglistnormal (under current, this means opened)
Output of the heating additional level variablelistnormal (under current, this means opened)
Output of the command value basic level coolinglistnormal (under current, this means opened)
Output of the cooling additional level variablelistnormal (under current, this means opened)
Output of the command values basic levellistnormal (under current, this means opened)
Output of the command values additional levellistnormal (under current, this means opened)
Heating indicationlistno
Cooling indicationlistno
Command value limit (not for switching 2-point control)listdeactivated
Command value limit after resetlistdeactivated
Minimum command value for heatinglist5%
Maximum command value for heatinglist95%
Minimum command value for coolinglist5%
Maximum command value for coolinglist95%
Minimum command value for heating/coolinglist5%
Maximum command value for heating/coolinglist95%
Minimum command value for heating basic levellist5%
Maximum command value for heating basic levellist95%
Minimum command value for heating additional levellist5%
Maximum command value for heating additional levellist95%
Minimum command value for cooling basic levellist5%
Maximum command value for cooling basic levellist95%
Minimum command value for heating/cooling basic levellist5%
Maximum command value for heating/cooling basic levellist95%
Minimum command value for heating/cooling additional levellist5%
Maximum command value for heating/cooling additional levellist95%
Controller statuslistno status
Single statuslistcomfort operation activated
Presence detectionlistpresence button
Duration of comfort extension minutes (0 = OFF)unsignedInt 0…25530
Switch off controller (dew point operation)listno
Underfloor heating temperature limitlistnot present
Effect onlistheating, basic level
Maximum temperature, underfloor heatingsignedInt 20…7030
Hysteresis of limit temperaturelist1 K
Command value for valve output (switching 1-bit)listcontroller 1 command value heating
Command value for valve output (continuous 1-byte)listcontroller 1 command value heating
Use internal group communication?listyes
Number of room temperature controllers usedlist6 controller
Output reacts to command value oflistcontroller 1
Command value for valve output (switching 1-bit)listcontroller 1 command value cooling
Command value for valve output (continuous 1-byte)listcontroller 1 command value cooling
Command value for valve output (switching 1-bit)listcontroller 1 command value heating/cooling
Command value for valve output (continuous 1-byte)listcontroller 1 command value heating/cooling
Command value for valve output (continuous 1-byte)listcontroller 1 command value basic level heating
Command value for valve output (switching 1-bit)listcontroller 1 command value basic level heating
Command value for valve output (switching 1-bit)listcontroller 1 command value additional level heating
Command value for valve output (continuous 1-byte)listcontroller 1 command value additional level heating
Command value for valve output (continuous 1-byte)listcontroller 1 command value basic level cooling
Command value for valve output (switching 1-bit)listcontroller 1 command value basic level cooling
Command value for valve output (switching 1-bit)listcontroller 1 command value additional level cooling
Command value for valve output (continuous 1-byte)listcontroller 1 command value additional level cooling
Command value for valve output (continuous 1-byte)listcontroller 1 command value basic level
Command value for valve output (switching 1-bit)listcontroller 1 command value basic level
Command value for valve output (continuous 1-byte)listcontroller 1 command value additional level
Command value for valve output (switching 1-bit)listcontroller 1 command value additional level
Command value for valve output (continuous 1-byte)listcontroller 2 command value heating
Command value for valve output (switching 1-bit)listcontroller 2 command value heating
Command value for valve output (continuous 1-byte)listcontroller 2 command value cooling
Command value for valve output (switching 1-bit)listcontroller 2 command value cooling
Command value for valve output (continuous 1-byte)listcontroller 2 command value heating/cooling
Command value for valve output (switching 1-bit)listcontroller 2 command value heating/cooling
Command value for valve output (continuous 1-byte)listcontroller 2 command value basic level heating
Command value for valve output (switching 1-bit)listcontroller 2 command value additional level heating
Command value for valve output (switching 1-bit)listcontroller 2 command value basic level heating
Command value for valve output (continuous 1-byte)listcontroller 2 command value additional level heating
Command value for valve output (continuous 1-byte)listcontroller 2 command value basic level cooling
Command value for valve output (switching 1-bit)listcontroller 2 command value additional level cooling
Command value for valve output (switching 1-bit)listcontroller 2 command value basic level cooling
Command value for valve output (continuous 1-byte)listcontroller 2 command value additional level cooling
Command value for valve output (continuous 1-byte)listcontroller 2 command value basic level
Command value for valve output (switching 1-bit)listcontroller 2 command value additional level
Command value for valve output (switching 1-bit)listcontroller 2 command value basic level
Command value for valve output (continuous 1-byte)listcontroller 2 command value additional level
Command value for valve output (continuous 1-byte)listcontroller 3 command value heating
Command value for valve output (switching 1-bit)listcontroller 3 command value heating
Command value for valve output (continuous 1-byte)listcontroller 3 command value cooling
Command value for valve output (switching 1-bit)listcontroller 3 command value cooling
Command value for valve output (continuous 1-byte)listcontroller 3 command value heating/cooling
Command value for valve output (switching 1-bit)listcontroller 3 command value heating/cooling
Command value for valve output (continuous 1-byte)listcontroller 3 command value basic level heating
Command value for valve output (switching 1-bit)listcontroller 3 command value additional level heating
Command value for valve output (switching 1-bit)listcontroller 3 command value basic level heating
Command value for valve output (continuous 1-byte)listcontroller 3 command value additional level heating
Command value for valve output (continuous 1-byte)listcontroller 3 command value basic level cooling
Command value for valve output (switching 1-bit)listcontroller 3 command value additional level cooling
Command value for valve output (switching 1-bit)listcontroller 3 command value basic level cooling
Command value for valve output (continuous 1-byte)listcontroller 3 command value additional level cooling
Command value for valve output (continuous 1-byte)listcontroller 3 command value basic level
Command value for valve output (switching 1-bit)listcontroller 3 command value additional level
Command value for valve output (switching 1-bit)listcontroller 3 command value basic level
Command value for valve output (continuous 1-byte)listcontroller 3 command value additional level
Command value for valve output (continuous 1-byte)listcontroller 4 command value heating
Command value for valve output (switching 1-bit)listcontroller 4 command value heating
Command value for valve output (continuous 1-byte)listcontroller 4 command value cooling
Command value for valve output (switching 1-bit)listcontroller 4 command value cooling
Command value for valve output (continuous 1-byte)listcontroller 4 command value heating/cooling
Command value for valve output (switching 1-bit)listcontroller 4 command value heating/cooling
Command value for valve output (continuous 1-byte)listcontroller 4 command value basic level heating
Command value for valve output (switching 1-bit)listcontroller 4 command value additional level heating
Command value for valve output (switching 1-bit)listcontroller 4 command value basic level heating
Command value for valve output (continuous 1-byte)listcontroller 4 command value additional level heating
Command value for valve output (continuous 1-byte)listcontroller 4 command value basic level cooling
Command value for valve output (switching 1-bit)listcontroller 4 command value additional level cooling
Command value for valve output (switching 1-bit)listcontroller 4 command value basic level cooling
Command value for valve output (continuous 1-byte)listcontroller 4 command value additional level cooling
Command value for valve output (continuous 1-byte)listcontroller 4 command value basic level
Command value for valve output (switching 1-bit)listcontroller 4 command value additional level
Command value for valve output (switching 1-bit)listcontroller 4 command value basic level
Command value for valve output (continuous 1-byte)listcontroller 4 command value additional level
Command value for valve output (continuous 1-byte)listcontroller 5 command value heating
Command value for valve output (switching 1-bit)listcontroller 5 command value heating
Command value for valve output (continuous 1-byte)listcontroller 5 command value cooling
Command value for valve output (switching 1-bit)listcontroller 5 command value cooling
Command value for valve output (continuous 1-byte)listcontroller 5 command value heating/cooling
Command value for valve output (switching 1-bit)listcontroller 5 command value heating/cooling
Command value for valve output (continuous 1-byte)listcontroller 5 command value basic level heating
Command value for valve output (switching 1-bit)listcontroller 5 command value additional level heating
Command value for valve output (switching 1-bit)listcontroller 5 command value basic level heating
Command value for valve output (continuous 1-byte)listcontroller 5 command value additional level heating
Command value for valve output (continuous 1-byte)listcontroller 5 command value basic level cooling
Command value for valve output (switching 1-bit)listcontroller 5 command value additional level cooling
Command value for valve output (switching 1-bit)listcontroller 5 command value basic level cooling
Command value for valve output (continuous 1-byte)listcontroller 5 command value additional level cooling
Command value for valve output (continuous 1-byte)listcontroller 5 command value basic level
Command value for valve output (switching 1-bit)listcontroller 5 command value additional level
Command value for valve output (switching 1-bit)listcontroller 5 command value basic level
Command value for valve output (continuous 1-byte)listcontroller 5 command value additional level
Command value for valve output (continuous 1-byte)listcontroller 6 command value heating
Command value for valve output (switching 1-bit)listcontroller 6 command value heating
Command value for valve output (continuous 1-byte)listcontroller 6 command value cooling
Command value for valve output (switching 1-bit)listcontroller 6 command value cooling
Command value for valve output (continuous 1-byte)listcontroller 6 command value heating/cooling
Command value for valve output (switching 1-bit)listcontroller 6 command value heating/cooling
Command value for valve output (continuous 1-byte)listcontroller 6 command value basic level heating
Command value for valve output (switching 1-bit)listcontroller 6 command value additional level heating
Command value for valve output (switching 1-bit)listcontroller 6 command value basic level heating
Command value for valve output (continuous 1-byte)listcontroller 6 command value additional level heating
Command value for valve output (continuous 1-byte)listcontroller 6 command value basic level cooling
Command value for valve output (switching 1-bit)listcontroller 6 command value additional level cooling
Command value for valve output (switching 1-bit)listcontroller 6 command value basic level cooling
Command value for valve output (continuous 1-byte)listcontroller 6 command value additional level cooling
Command value for valve output (continuous 1-byte)listcontroller 6 command value basic level
Command value for valve output (switching 1-bit)listcontroller 6 command value additional level
Command value for valve output (switching 1-bit)listcontroller 6 command value basic level
Command value for valve output (continuous 1-byte)listcontroller 6 command value additional level
Output reacts to command value oflistno internal command value
Output reacts to command value oflistcontroller 2
Output reacts to command value oflistcontroller 3
Output reacts to command value oflistcontroller 4
Output reacts to command value oflistcontroller 5
Output reacts to command value oflistcontroller 6

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Valve Drive Controller 2073/1.2 1.2 latest$20735A7B2026-11-251.1 MBDownload
Valve Drive Controller 2073/1.2 1.2$20735A7B2026-11-251.1 MBDownload

About this file

This is the official ETS product database for the Schneider Electric Industries SAS SpaceLogic KNX Valve Drive Controller (MTN6730-0002), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Schneider Electric Industries SAS

All Schneider Electric Industries SAS products