Schneider Electric Industries SAS MTN6221-03xx Room temperature control unit for properties

Room temperature control unit for properties MTN6221-03xx

Schneider Electric Industries SAS · Order number MTN6221-03xx · 7.1 Heating/Single Room Thermostat › 7.1.5 Thermostat, System M

MTN6221-03xx

Download .knxprod Object RTCU 1819/1.0 1.0 · 288 KB

Product

ManufacturerSchneider Electric Industries SAS
Product nameRoom temperature control unit for properties
Order numberMTN6221-03xx
HardwareRaumtemperaturregler für den Objektbereich
MediumTwisted Pair
Rail mountedNo
RegistrationCertified
Languagesen-US, de-DE, fr-FR, da-DK, nl-NL, it-IT, sv-SE, es-ES
Catalog entryM-0064_H-MTN6221.2D04xx-1-O000C_HP-1819-10-D03D-O000C_CI-MTN6221.2D03xx-0
FingerprintD03D
SHA-256e8b09233f23207f7fa81ea3b20e203d845946eae01023bdeb27f036938d9b5fc
First seen2026-11-25
Markets59 markets

Application program: Object RTCU 1819/1.0 1.0

Application number$1819
Version1.0
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Parameters382
Group objects113
Group objects (113)
NoNameFunctionSizeDPTFlags
0Object 12 BytesCRWTU
1Object 21 ByteCRWTU
2Object 31 BitCRWTU
3Object 42 BytesCRWTU
4Object 51 ByteCRWTU
5Object 61 BitCRWTU
6Object 72 BytesCRWTU
7Object 81 ByteCRWTU
8Object 91 BitCRWTU
9Object 102 BytesCRWTU
10Object 111 ByteCRWTU
11Object 121 BitCRWTU
12Object 132 BytesCRWTU
13Object 141 ByteCRWTU
14Object 151 BitCRWTU
15Object 162 BytesCRWTU
16Object 171 ByteCRWTU
17Object 181 BitCRWTU
18Object 192 BytesCRWTU
19Object 201 ByteCRWTU
20Object 211 BitCRWTU
21Object 222 BytesCRWTU
22Object 231 ByteCRWTU
23Object 241 BitCRWTU
24Object 251 BitCRWTU
25Object 261 BitCRWTU
26Object 271 ByteCRWTU
27Object 281 ByteCRWTU
28Object 291 ByteCRWTU
29Object 301 ByteCRWTU
30Object 311 ByteCRWTU
31Object 321 ByteCRWTU
32Object 331 ByteCRWTU
33Object 342 BytesCRWTU
34Object 351 ByteCRWTU
35Object 361 BitCRWTU
36Object 371 BitCRWTU
36Signal object outputSignal function1 BitCT
37Object 382 BytesCRWTU
38Object 391 BitCRWTU
39Object 401 ByteCRWTU
40Object 412 BytesCRWTU
40Setpoint adjustment inputControl2 BytesCW
41Object 422 BytesCRWTU
41Current setpoint temperature inputControl2 BytesCW
42Object 432 BytesCRWTU
42Current actual temperature inputControl2 BytesCWTU
43Object 441 BitCRWTU
43Dewpoint alarmControl1 BitCW
44Object 451 BitCRWTU
44Disable object inputControl1 BitCW
45Object 461 BitCRWTU
45Frost/heat protection inputControl1 BitCW
46Object 471 BitCRWTU
46Comfort extension inputControl1 BitCW
47Object 481 BitCRWTU
47Comfort inputControl1 BitCW
48Object 491 ByteCRWTU
48Night reduction inputControl1 BitCW
48Operation mode inputControl1 ByteCW
49Object 501 BitCRWTU
49Heating / cooling inputControl1 BitCWTU
50Object 512 BytesCRWTU
50Setpoint adjustment outputControl2 BytesCRT
51Object 522 BytesCRWTU
51Current setpoint temperature outputControl2 BytesCRT
52Object 532 BytesCRWTU
52Current actual temperature outputControl2 BytesCRT
53Object 541 BitCRWTU
54Object 551 BitCRWTU
55Object 561 BitCRWTU
55Comfort extension outputControl1 BitCRT
56Object 571 BitCRWTU
57Object 581 ByteCRWTU
58Object 591 BitCRWTU
58Heating / cooling outputControl1 BitCRT
59Object 601 BitCRWTU
59Status (heating / cooling)Control1 BitCRT
59Status (dewpoint alarm)Control1 BitCRT
59Status (frost/heat protrection)Control1 BitCRT
59Status (night mode)Control1 BitCRT
59Status (comfort)Control1 BitCRT
59Status (standby)Control1 BitCRT
59Status (frost alarm)Control1 BitCRT
59Status (controller inactive)Control1 BitCRT
60Object 611 ByteCRWTU
60StatusControl1 ByteCRT
61Object 622 BytesCRWTU
61StatusControl2 BytesCRT
62Object 631 ByteCRWTU
62Correcting variable heating (basic level)Control1 BitCRT
62Correcting variable heating (basic level)Control1 ByteCRT
63Object 641 ByteCRWTU
63Status heating (basic level)Control1 ByteCRT
64Object 651 ByteCRWTU
64Correcting variable heating (additional level)Control1 BitCRT
64Correcting variable heating (additional level)Control1 ByteCRT
65Object 661 ByteCRWTU
65Correcting variable cooling (basic level)Control1 BitCRT
65Correcting variable cooling (basic level)Control1 ByteCRT
66Object 671 ByteCRWTU
66Status cooling (basic level)Control1 ByteCRT
67Object 681 ByteCRWTU
67Correcting variable cooling (additional level)Control1 BitCRT
67Correcting variable cooling (additional level)Control1 ByteCRT
68Object 698 BytesCRWTU
69Object 703 BytesCRWTU
70Object 711 BitCRWTU
71Object 728 BytesCRWTU
72Object 733 BytesCRWTU
73Object 741 BitCRWTU
74Object 752 BytesCRWTU
75Object 762 BytesCRWTU
Parameters (127)
ParameterTypeDefault
OriginallistCopy
Fully generatedlistDummy
InternallistDummy
Brightness of status LEDunsignedInt 0…25550
Brightness of operational LEDunsignedInt 0…25550
NotelistDummy
GenerallistDummy
Download detectionunsignedInt 0…255255
ETS IDunsignedInt 0…25524
ETS IDunsignedInt 0…25525
ETS VersionunsignedInt 0…2558
ETS VersionunsignedInt 0…2550
Switch on operational LEDlistNo
Switch on acoustic push-button acknowledgementlistNo
IR rangelistIR range 1 - 10
Switched offunsignedInt 0…2550
Start-up delay for the device in s (0-255)unsignedInt 0…2554
Debaunce IR receiverlistNo
DisplaylistDummy
Signal functionlistDummy
Use signal functionlistNo
Switched onlistDummy
Report when actual temp. is less than frost or greater than heat protec. temp.listNo
Report when limits of setpoint adjustment are reachedlistNo
Type of signallinglistJust flashing display
The acoustic signal stopslistAfter a parameterised time
Signal time in s (1-254)unsignedInt 1…25460
Signal timeunsignedInt 0…2550
Report when actual temp. is greater thanlistNo
Report when actual temp. is less thanlistNo
Push-button infolistDummy
Disable function for push-buttonslistDummy
Apply disable functionlistNo
Scene modulelistAdjustment via control parameter
Scene actuator groupslistDummy
Scene 1listDummy
Scene 1 - valueslistDummy
Time controllistDummy
Use time controllistNo
Overwrite switching timeslistYes
Carry out switching timelistNo
Select scene address internallylistNo
Control generallistDummy
Use controllistYes
Controller typelistHeating
Manual operation of controllerlistYes
Duration of comfort extensionlist1.0 h.
Termination of comfort extension via objects*listNo
Operation mode after comfort extensionlistNight mode
Operation mode after resetlistStandby mode
Operation mode after downloadlistStandby mode
On what the setpoint adjustment has an effectlistCurrent operation mode
Setpoint adjustment maintained after change in operation modelistNo
Max. upper setpoint adjustmentlist3 K
Max. lower setpoint adjustmentlist3 K
Toggle between heating and coolinglistAutomatically (via controller)
Read request heating/cooling object after bus voltage recoverylistNo
Waiting time after switching-over (heating/cooling)listNo
Wating time (1-60 min.)unsignedInt 0…2550
Wating time (1-60 min.)unsignedInt 1…6010
Operation mode / StatuslistDummy
Toggle operation mode via 1 bit/1 bytelist1 bit
Prio 1 bit frost protection = 1 byte frost protectionlistNo
Status objectslistDummy
Define 1 bit status objectlistBit 3: Frost/heat protection
SetpointslistDummy
Reference setpoint for the calculation of the setpoint adjustmentlist21.0 °C = 69.8 °F
Setpoint comfortlist21.0 °C = 69.8 °F
Setpoint standbylist19.0 °C = 66.2 °F
Setpoint nightlist17.0 °C = 62.6 °F
Setpoint frost protectionlist 7.0 °C = 44.6 °F
Setpoint comfortlist24.0 °C = 75.2 °F
Setpoint standbylist26.0 °C = 78.8 °F
Setpoint nightlist28.0 °C = 82.4 °F
Setpoint heat protectionlist35.0 °C = 95.0 °F
Actual temperature (resultant)listDummy
Correct internal actual temperature factor (-128 ... 127) * 0,1 KsignedInt -128…1270
Delay internal actual temperaturelistNo
Account external actual temperature proportionatelylistNo
Monitor external actual temperature every ... min (0-255)unsignedInt 0…25560
Send actual temperature at a deviation of ... Klist0.2 K
Send actual temperature every ... minlist10 min.
Temperature jumplistDummy
Temperature jump detectionlistNo
Duration of frost/heat protection at temperature jump (10-60 min)unsignedInt 10…6020
Temperature measurementlistFrom (resultant) actual temperature
Control heatinglistDummy
Limit integral partlistYes
Limit integral part at heating/cooling switch-overlistYes
Direction of control action of controllerlistNormal
Output of correcting variablelistPI control (continuous)
Select heating systemlistWarm water heating (5 K/150 min.)
Proportional range for heating in 0.1 K (10-255)unsignedInt 10…25540
Hysteresislist0.5 K
Reset time for cooling in min. (1-255)list100
Reset time for heating (1-255 min.)list100
Use additional levellistNo
Control heating (additional level)listDummy
Output of correcting variablelist2-step control (switching)
Level interval factor (10 ... 100) * 0.1 KunsignedInt 10…10020
Control coolinglistDummy
Select cooling systemlistCooling ceiling (5 K / 240 min.)
Proportional range for cooling in 0.1 K (10-255)unsignedInt 10…25550
Reset time for cooling in min. (1-255)list240
Reset time for cooling (1-255 min.)list240
Control cooling (additional level)listDummy
Correcting variables heatinglistDummy
Cycle time of switching correcting variable (2-60 min.)unsignedInt 2…6015
Range of minimum correcting variable from 0 % to ... %list0 %
Minimum correcting variable (0% - 100%)list0 %
Range of maximum correcting variable from 100 % to ... %list100 %
Maximum correcting variable (0% - 100%)list100 %
Change for sending of correcting variablelist3 %
Change for sending of correcting variablelistON telegram
Send correcting variable cyclicallylistYes
Cycle time for automatic sending of correcting variable in min. (1-60)unsignedInt 0…2550
Cycle time for automatic sending of correcting variable in min. (1-60)unsignedInt 1…6030
Inactive correcting variable send cyclicallylistYes
Use valve protectionlistNo
Activate valve protection every ... days (1-30)unsignedInt 1…3015
Activate valve protection every ... days (1-30)unsignedInt 0…2550
Move to end position for ... min. (1-30)unsignedInt 1…304
Change for automatic sending of correcting variablelistON telegram
Correcting variables coolinglistDummy
Display of extern. temperaturelistDummy
Factor for cycle time = 0unsignedInt 0…2550
Fan steplistDummy

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Object RTCU 1819/1.0 1.0 latest$1819D03D2026-11-25288 KBDownload

About this file

This is the official ETS product database for the Schneider Electric Industries SAS Room temperature control unit for properties (MTN6221-03xx), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.