Schneider Electric Industries SAS MTN6005-0011 Air Quality Multisensor

Air Quality Multisensor MTN6005-0011

Schneider Electric Industries SAS · Order number MTN6005-0011 · 2.9 Physical Sensors › 2.9.05 Carbon Dioxide

Download .knxprod Multisensor 4217/1.0a 1.0 · 491 KB

Product

ManufacturerSchneider Electric Industries SAS
Product nameAir Quality Multisensor
Order numberMTN6005-0011
HardwareMTN6005-0011
MediumTwisted Pair
Bus current (mA)12
Rail mountedNo
Device kindAccessory, RFRetransmitter
RegistrationCertified · 2021-11-18
Languagesen-US, de-DE, fr-FR, da-DK, nl-NL, it-IT, sv-SE, es-ES, ru-RU
Catalog entryM-0064_H-MTN6005.2D0011-9-O00FC_HP-4217-10-0ABC-O00FC_CI-MTN6005.2D0011-2
Fingerprint0ABC
SHA-2565353d901ccad3e6f4ed1fa8d1fb6ac22c05fc834087ac5ac099dcb86cdd0afdb
First seen2026-11-25
Markets59 markets

Application program: Multisensor 4217/1.0a 1.0

Application number$4217
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters1586
Group objects508
Group objects (508)
NoNameFunctionSizeDPTFlags
1Send '0' in operationOutput1 BitDPT.1CT
1Send '1' in operationOutput1 BitDPT.1CT
2Request statusInput1 BitDPT.1CW
3operating hours counter[s]Output (read only)4 BytesDPT.13CR
4Enable/disable CO2 and RH LEDsInput1 BitDPT.1CW
16T: heat alarmOutput1 BitDPT.1CT
17T: frost alarmOutput1 BitDPT.1CT
18RTC: external temperature value 1Input2 BytesDPT.9CW
19RTC: external temperature value 2Input2 BytesDPT.9CW
20RTC: external temperature value 3Input2 BytesDPT.9CW
21RTC: external temperature value 4Input2 BytesDPT.9CW
22RTC: comfort temperatureInput2 BytesDPT.9CRW
23RTC: standby setback when heatingInput2 BytesDPT.9CRW
24RTC: eco setback when heatingInput2 BytesDPT.9CRW
25RTC: standby increment when coolingInput2 BytesDPT.9CRW
26RTC: eco increment when coolingInput2 BytesDPT.9CRW
27RTC: frost protection temperature when heatingInput2 BytesDPT.9CRW
28RTC: heat protection temperature when coolingInput2 BytesDPT.9CRW
29RTC: current set point temperatureOutput2 BytesDPT.9CRT
30RTC: average comfort set point temperature (symmetrical)Output2 BytesDPT.9CRT
31RTC: comfort temperature +/- 0,1KInput1 BitDPT.1CW
32RTC: comfort temperature +/- 0,5KInput1 BitDPT.1CW
33RTC: standby setback when heating +/- 0,1KInput1 BitDPT.1CW
34RTC: eco setback when heating +/- 0,1KInput1 BitDPT.1CW
35RTC: standby increment when cooling +/- 0,1KInput1 BitDPT.1CW
36RTC: eco increment when cooling +/- 0,1KInput1 BitDPT.1CW
37RTC: heating(1)/cooling(0)Input1 BitDPT.1CW
38RTC: status heating/coolingOutput1 BitDPT.1CRT
39RTC: Dead zone between heating and cooling (0…10K)Input2 BytesDPT.9CW
40RTC: HVAC Mode: 1=comf, 2=stdb, 3=eco, 4=b-protInput1 ByteDPT.20CW
41RTC: HVAC Mode: 1=comf, 2=stdb, 3=eco, 4=b-protOutput1 ByteDPT.20CRT
42RTC: comfort mode enableInput1 BitDPT.1CW
43RTC: standby mode enableInput1 BitDPT.1CW
44RTC: eco mode enableInput1 BitDPT.1CW
45RTC: Frost-/heat protection enableInput1 BitDPT.1CW
46RTC: setpoint override valueInput2 BytesDPT.9CW
47RTC: status heatingOutput1 BitDPT.1CT
48RTC: status coolingOutput1 BitDPT.1CT
49RTC: RHCC statusOutput2 BytesDPT.22CRT
50RTC: control value main level heatingOutput1 ByteDPT.5CT
50RTC: control value main level heatingOutput1 BitDPT.1CT
51RTC: control value extra level heatingOutput1 ByteDPT.5CT
51RTC: control value extra level heatingOutput1 BitDPT.1CT
52RTC: control value main level coolingOutput1 ByteDPT.5CT
52RTC: control value main level coolingOutput1 BitDPT.1CT
53RTC: control value extra level coolingOutput1 ByteDPT.5CT
53RTC: control value extra level coolingOutput1 BitDPT.1CT
54RTC: guide value [°C]Input2 BytesDPT.9CW
55RTC: blocking object heatingInput1 BitDPT.1CW
56RTC: blocking object coolingInput1 BitDPT.1CW
57RTC: blocking object extra level heatingInput1 BitDPT.1CW
58RTC: blocking object extra level coolingInput1 BitDPT.1CW
59RTC: Reset manual offsetInput1 BitDPT.1CW
60RTC: Block manual offsetInput1 BitDPT.1CW
61RTC: Manual offset valueOutput2 BytesDPT.9CT
62Party start/stop/retriggerInput1 BitDPT.1CW
66HUMCMP: Absolute humidity value 1 [g/m3]Input2 BytesDPT.9CW
66HUMCMP: Relative humidity value 1 [%]Input1 ByteDPT.5CW
67HUMCMP: Temperature value 1 [°C]Input2 BytesDPT.9CW
68HUMCMP: Absolute humidity value 2 [g/m3]Input2 BytesDPT.9CW
68HUMCMP: Relative humidity value 2 [%]Input1 ByteDPT.5CW
69HUMCMP: Temperature value 2 [°C]Input2 BytesDPT.9CW
70HUMCMP: Humidity comparator outputOutput1 BitDPT.1CT
71DEWP: dew point temperature [°C]Output2 BytesDPT.9CT
72DEWP: dew point alarm enabled (switching object)Output1 BitDPT.1CT
72DEWP: dew point alarm enabled (priority)Output2 BitDPT.2CT
72DEWP: dew point alarm enabled (0...100%)Output1 ByteDPT.5CT
72DEWP: dew point alarm enabled (0...255)Output1 ByteDPT.5CT
72DEWP: dew point alarm enabled scene (1...64)Output1 ByteDPT.17CT
73DEWP: request dew point temperatureInput1 BitDPT.1CW
74P: absolute air pressure [Pa]Output2 BytesDPT.9CT
75P: relative air pressure [Pa]Output2 BytesDPT.9CT
76P: air pressure sensor errorOutput1 BitDPT.1CT
77P: request absolute air pressureInput1 BitDPT.1CW
78P: request relative air pressureInput1 BitDPT.1CW
79VAVC: control value (0...255)Output1 ByteDPT.5CT
79VAVC: control value (0...100%)Output1 ByteDPT.5CT
80VAVC: external object (0…100%)Input1 ByteDPT.5CW
81VAVC: Input set selection.Input1 BitDPT.1CW
82VAVC: blocking objectInput1 BitDPT.1CW
86CO2C: external CO2 value 1 [ppm]Input2 BytesDPT.9CW
87CO2C: external CO2 value 2 [ppm]Input2 BytesDPT.9CW
88CO2C: external CO2 value 3 [ppm]Input2 BytesDPT.9CW
89CO2C: external CO2 value 4 [ppm]Input2 BytesDPT.9CW
90CO2C: control value (0...255)Output1 ByteDPT.5CT
90CO2C: control value (0...100%)Output1 ByteDPT.5CT
90CO2C: scene (1...64)Output1 ByteDPT.17CT
90CO2C: control value level 1 (switching object)Output1 BitDPT.1CT
90CO2C: control value level 1 (priority)Output2 BitDPT.2CT
91CO2C: control value level 2 (switching object)Output1 BitDPT.1CT
91CO2C: control value level 2 (priority)Output2 BitDPT.2CT
92CO2C: control value level 3 (switching object)Output1 BitDPT.1CT
92CO2C: control value level 3 (priority)Output2 BitDPT.2CT
93CO2C: base set point [ppm]Input2 BytesDPT.9CW
95CO2C: blocking object level 1Input1 BitDPT.1CW
96CO2C: blocking object level 2Input1 BitDPT.1CW
97CO2C: blocking object level 3Input1 BitDPT.1CW
98CO2C: blocking objectInput1 BitDPT.1CW
99RHC: humidity external value 1 [%]Input1 ByteDPT.5CW
100RHC: external humidity value 2 [%]Input1 ByteDPT.5CW
101RHC: external humidity value 3 [%]Input1 ByteDPT.5CW
102RHC: external humidity value 4 [%]Input1 ByteDPT.5CW
103RHC: control value (0...255)Output1 ByteDPT.5CT
103RHC: control value (0...100%)Output1 ByteDPT.5CT
103RHC: scene (1...64)Output1 ByteDPT.17CT
103RHC: control value level 1 (switching object)Output1 BitDPT.1CT
103RHC: control value level 1 (priority)Output2 BitDPT.2CT
104RHC: control value level 2 (switching object)Output1 BitDPT.1CT
104RHC: control value level 2 (priority)Output2 BitDPT.2CT
105RHC: control value level 3 (switching object)Output1 BitDPT.1CT
105RHC: control value level 3 (priority)Output2 BitDPT.2CT
106RHC: base set point [%]Input2 BytesDPT.9CW
107RHC: base set point (1 byte) [%]Input1 ByteDPT.5CW
108RHC: blocking object level 1Input1 BitDPT.1CW
109RHC: blocking object level 2Input1 BitDPT.1CW
110RHC: blocking object level 3Input1 BitDPT.1CW
111RHC: blocking objectInput1 BitDPT.1CW
112CO2: CO2 value [ppm]Output2 BytesDPT.9CT
114CO2: request CO2 valueInput1 BitDPT.1CW
115CO2: sensor errorOutput1 BitDPT.1CT
116CO2: start/stop calibrationInput1 BitDPT.1CW
117CO2: adopt CO2 calibration valueInput2 BytesDPT.9CW
118CO2: CO2 value external [ppm]Input2 BytesDPT.9CT
119CO2: min valueOutput2 BytesDPT.9CT
120CO2: max valueOutput2 BytesDPT.9CT
121CO2: request min/max valuesInput1 BitDPT.1CW
122CO2: reset min/max valuesInput1 BitDPT.1CW
123rH: humidity value [%]Output2 BytesDPT.9CT
124rH: humidity value (1 byte) [%]Output1 ByteDPT.5CT
125rH: request humidity valueInput1 BitDPT.1CW
126rH: sensor error Output1 BitDPT.1CT
129rH: humidity value external [%]Input2 BytesDPT.9CT
130rH: min valueOutput2 BytesDPT.9CT
131rH: max valueOutput2 BytesDPT.9CT
132rH: request min/max valuesInput1 BitDPT.1CW
133rH: reset min/max valuesInput1 BitDPT.1CW
134T: temperature value [°C]Output2 BytesDPT.9CT
136T: request temperature valueInput1 BitDPT.1CW
137T: sensor error Output1 BitDPT.1CT
140T: Temperature value external [°C]Input2 BytesDPT.9CT
141T: temperature min valueOutput2 BytesDPT.9CT
142T: temperature max valueOutput2 BytesDPT.9CT
143T: request min/max temperature valuesInput1 BitDPT.1CW
144T: reset min/max temperature valuesInput1 BitDPT.1CW
152E1 Switching sensorOutput1 BitDPT.1CWT
152E1 Alarm sensorOutput1 BitDPT.1CWT
152E1 SwitchingOutput1 BitDPT.1CWT
152E1 Blind UP/DOWNOutput1 BitDPT.1CWT
152E1 Switch (event 0)Output1 BitDPT.1CT
152E1 Priority (event 0)Output2 BitDPT.2CT
152E1 1-byte value (-128 to 127) (event 0)Output1 ByteDPT.6CT
152E1 1-byte value (0 to 255) (event 0)Output1 ByteDPT.5CT
152E1 Scene (event 0)Output1 ByteDPT.18CT
152E1 2-byte value (-32,768 to 32,767) (event 0)Output2 BytesDPT.8CT
152E1 2-byte value (0 to 65,535) (event 0)Output2 BytesDPT.7CT
152E1 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0)Output4 BytesDPT.13CT
152E1 4-byte value (0 to 4294967295) (event 0)Output4 BytesDPT.12CT
152E1 2-byte floating point (event 0)Output2 BytesDPT.9CT
152E1 SceneOutput1 ByteDPT.18CWTU
152E1 Switching step 1Output1 BitDPT.1CWT
152E1 Switching 1 actuationOutput1 BitDPT.1CWT
152E1 HZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
152E1 HZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
152E1 HZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
152E1 HZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
152E1 HZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
152E1 1-byte value (-128 to 127)Output1 ByteDPT.6CT
152E1 1-byte value (0 to 255)Output1 ByteDPT.5CT
152E1 2-byte value (-32,768 to 32,767)Output2 BytesDPT.8CT
152E1 2-byte value (0 to 65,535)Output2 BytesDPT.7CT
152E1 2-byte floating pointOutput2 BytesDPT.9CT
152E1 4-byte floating pointOutput4 BytesDPT.14CT
153E1 DimmingOutput4 BitDPT.3CT
153E1 STOP/slat adjustmentOutput1 BitDPT.1CT
153E1 Switch (event 1)Output1 BitDPT.1CT
153E1 Priority (event 1)Output2 BitDPT.2CT
153E1 1-byte value (-128 to 127) (event 1)Output1 ByteDPT.6CT
153E1 1-byte value (0 to 255) (event 1)Output1 ByteDPT.5CT
153E1 Scene (event 1)Output1 ByteDPT.18CT
153E1 2-byte value (-32,768 to 32,767) (event 1)Output2 BytesDPT.8CT
153E1 2-byte value (0 to 65,535) (event 1)Output2 BytesDPT.7CT
153E1 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1)Output4 BytesDPT.13CT
153E1 4-byte value (0 to 4294967295) (event 1)Output4 BytesDPT.12CT
153E1 2-byte floating point (event 1)Output2 BytesDPT.9CT
153E1 Switching step 2Output1 BitDPT.1CWT
153E1 Switching 2 actuationsOutput1 BitDPT.1CWT
153E1 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
153E1 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
153E1 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
153E1 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
153E1 ZZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
153Request E1Input1 BitDPT.1CW
154E1 Start event 0/1Input1 BitDPT.1CW
154E1 Top end positionInput1 BitDPT.1CW
154E1 Scene storage displayOutput1 BitDPT.1CT
154E1 Switching step 3Output1 BitDPT.1CWT
154E1 Switching 3 actuationsOutput1 BitDPT.1CWT
154E1 HZ: Request counter readingInput1 BitDPT.1CW
154E1 Outside of rangeOutput1 BitDPT.1CT
155E1 Bottom end positionInput1 BitDPT.1CW
155E1 Switching step 4Output1 BitDPT.1CWT
155E1 Switching 4 actuationsOutput1 BitDPT.1CWT
155E1 HZ: Limit value exceededOutput1 BitDPT.1CT
155E1 Threshold valueOutput1 BitDPT.1CT
155E1 Threshold valueOutput1 ByteDPT.5CT
155E1 Threshold valueOutput2 BytesDPT.7CT
155E1 Threshold valueOutput2 BytesDPT.9CT
156E1 Save sceneInput1 BitDPT.1CW
156E1 Enable saveInput1 BitDPT.1CW
156E1 Switching step 5Output1 BitDPT.1CWT
156E1 Switching, long actuationOutput1 BitDPT.1CWT
157E1 Switch step UP/DOWNInput1 BitDPT.1CW
157E1 ZZ: Limit value exceededOutput1 BitDPT.1CT
157E1 Change threshold, tolerance band lower limitInput1 ByteDPT.5CW
158E1 Actuating numberInput1 ByteDPT.5CWTU
158E1 ZZ: Request counter readingInput1 BitDPT.1CW
158E1 Change threshold, tolerance band upper limitInput1 ByteDPT.5CW
159E1 ZZ: Reverse directionInput1 BitDPT.1CW
159E1 Send if threshold value undershotInput1 ByteDPT.5CW
159E1 Send if threshold value undershotInput2 BytesDPT.7CW
159E1 Send if threshold value undershotInput2 BytesDPT.9CW
160E1 ZZ: ResetInput1 BitDPT.1CW
160E1 Send if threshold value exceededInput1 ByteDPT.5CW
160E1 Send if threshold value exceededInput2 BytesDPT.7CW
160E1 Send if threshold value exceededInput2 BytesDPT.9CW
161E1 ZZ: StopInput1 BitDPT.1CW
170E1 DisableInput1 BitDPT.1CW
172E2 Switching sensorOutput1 BitDPT.1CWT
172E2 Alarm sensorOutput1 BitDPT.1CWT
172E2 SwitchingOutput1 BitDPT.1CWT
172E2 Blind UP/DOWNOutput1 BitDPT.1CWT
172E2 Switch (event 0)Output1 BitDPT.1CT
172E2 Priority (event 0)Output2 BitDPT.2CT
172E2 1-byte value (-128 to 127) (event 0)Output1 ByteDPT.6CT
172E2 1-byte value (0 to 255) (event 0)Output1 ByteDPT.5CT
172E2 Scene (event 0)Output1 ByteDPT.18CT
172E2 2-byte value (-32,768 to 32,767) (event 0)Output2 BytesDPT.8CT
172E2 2-byte value (0 to 65,535) (event 0)Output2 BytesDPT.7CT
172E2 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0)Output4 BytesDPT.13CT
172E2 4-byte value (0 to 4294967295) (event 0)Output4 BytesDPT.12CT
172E2 2-byte floating point (event 0)Output2 BytesDPT.9CT
172E2 SceneOutput1 ByteDPT.18CWTU
172E2 Switching step 1Output1 BitDPT.1CWT
172E2 Switching 1 actuationOutput1 BitDPT.1CWT
172E2 HZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
172E2 HZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
172E2 HZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
172E2 HZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
172E2 HZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
173E2 DimmingOutput4 BitDPT.3CT
173E2 STOP/slat adjustmentOutput1 BitDPT.1CT
173E2 Switch (event 1)Output1 BitDPT.1CT
173E2 Priority (event 1)Output2 BitDPT.2CT
173E2 1-byte value (-128 to 127) (event 1)Output1 ByteDPT.6CT
173E2 1-byte value (0 to 255) (event 1)Output1 ByteDPT.5CT
173E2 Scene (event 1)Output1 ByteDPT.18CT
173E2 2-byte value (-32,768 to 32,767) (event 1)Output2 BytesDPT.8CT
173E2 2-byte value (0 to 65,535) (event 1)Output2 BytesDPT.7CT
173E2 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1)Output4 BytesDPT.13CT
173E2 4-byte value (0 to 4294967295) (event 1)Output4 BytesDPT.12CT
173E2 2-byte floating point (event 1)Output2 BytesDPT.9CT
173E2 Switching step 2Output1 BitDPT.1CWT
173E2 Switching 2 actuationsOutput1 BitDPT.1CWT
173E2 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
173E2 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
173E2 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
173E2 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
173E2 ZZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
174E2 Start event 0/1Input1 BitDPT.1CW
174E2 Top end positionInput1 BitDPT.1CW
174E2 Scene storage displayOutput1 BitDPT.1CT
174E2 Switching step 3Output1 BitDPT.1CWT
174E2 Switching 3 actuationsOutput1 BitDPT.1CWT
174E2 HZ: Request counter readingInput1 BitDPT.1CW
175E2 Bottom end positionInput1 BitDPT.1CW
175E2 Switching step 4Output1 BitDPT.1CWT
175E2 Switching 4 actuationsOutput1 BitDPT.1CWT
175E2 HZ: Limit value exceededOutput1 BitDPT.1CT
176E2 Save sceneInput1 BitDPT.1CW
176E2 Enable saveInput1 BitDPT.1CW
176E2 Switching step 5Output1 BitDPT.1CWT
176E2 Switching, long actuationOutput1 BitDPT.1CWT
177E2 Switch step UP/DOWNInput1 BitDPT.1CW
177E2 ZZ: Limit value exceededOutput1 BitDPT.1CT
178E2 Actuating numberInput1 ByteDPT.5CWTU
178E2 ZZ: Request counter readingInput1 BitDPT.1CW
179E2 ZZ: Reverse directionInput1 BitDPT.1CW
180E2 ZZ: ResetInput1 BitDPT.1CW
181E2 ZZ: StopInput1 BitDPT.1CW
190E2 DisableInput1 BitDPT.1CW
192E3 Switching sensorOutput1 BitDPT.1CWT
192E3 Alarm sensorOutput1 BitDPT.1CWT
192E3 SwitchingOutput1 BitDPT.1CWT
192E3 Blind UP/DOWNOutput1 BitDPT.1CWT
192E3 Switch (event 0)Output1 BitDPT.1CT
192E3 Priority (event 0)Output2 BitDPT.2CT
192E3 1-byte value (-128 to 127) (event 0)Output1 ByteDPT.6CT
192E3 1-byte value (0 to 255) (event 0)Output1 ByteDPT.5CT
192E3 Scene (event 0)Output1 ByteDPT.18CT
192E3 2-byte value (-32,768 to 32,767) (event 0)Output2 BytesDPT.8CT
192E3 2-byte value (0 to 65,535) (event 0)Output2 BytesDPT.7CT
192E3 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0)Output4 BytesDPT.13CT
192E3 4-byte value (0 to 4294967295) (event 0)Output4 BytesDPT.12CT
192E3 2-byte floating point (event 0)Output2 BytesDPT.9CT
192E3 SceneOutput1 ByteDPT.18CWTU
192E3 Switching step 1Output1 BitDPT.1CWT
192E3 Switching 1 actuationOutput1 BitDPT.1CWT
192E3 HZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
192E3 HZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
192E3 HZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
192E3 HZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
192E3 HZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
193E3 DimmingOutput4 BitDPT.3CT
193E3 STOP/slat adjustmentOutput1 BitDPT.1CT
193E3 Switch (event 1)Output1 BitDPT.1CT
193E3 Priority (event 1)Output2 BitDPT.2CT
193E3 1-byte value (-128 to 127) (event 1)Output1 ByteDPT.6CT
193E3 1-byte value (0 to 255) (event 1)Output1 ByteDPT.5CT
193E3 Scene (event 1)Output1 ByteDPT.18CT
193E3 2-byte value (-32,768 to 32,767) (event 1)Output2 BytesDPT.8CT
193E3 2-byte value (0 to 65,535) (event 1)Output2 BytesDPT.7CT
193E3 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1)Output4 BytesDPT.13CT
193E3 4-byte value (0 to 4294967295) (event 1)Output4 BytesDPT.12CT
193E3 2-byte floating point (event 1)Output2 BytesDPT.9CT
193E3 Switching step 2Output1 BitDPT.1CWT
193E3 Switching 2 actuationsOutput1 BitDPT.1CWT
193E3 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
193E3 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
193E3 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
193E3 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
193E3 ZZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
194E3 Start event 0/1Input1 BitDPT.1CW
194E3 Top end positionInput1 BitDPT.1CW
194E3 Scene storage displayOutput1 BitDPT.1CT
194E3 Switching step 3Output1 BitDPT.1CWT
194E3 Switching 3 actuationsOutput1 BitDPT.1CWT
194E3 HZ: Request counter readingInput1 BitDPT.1CW
195E3 Bottom end positionInput1 BitDPT.1CW
195E3 Switching step 4Output1 BitDPT.1CWT
195E3 Switching 4 actuationsOutput1 BitDPT.1CWT
195E3 HZ: Limit value exceededOutput1 BitDPT.1CT
196E3 Save sceneInput1 BitDPT.1CW
196E3 Enable saveInput1 BitDPT.1CW
196E3 Switching step 5Output1 BitDPT.1CWT
196E3 Switching, long actuationOutput1 BitDPT.1CWT
197E3 Switch step UP/DOWNInput1 BitDPT.1CW
197E3 ZZ: Limit value exceededOutput1 BitDPT.1CT
198E3 Actuating numberInput1 ByteDPT.5CWTU
198E3 ZZ: Request counter readingInput1 BitDPT.1CW
199E3 ZZ: Reverse directionInput1 BitDPT.1CW
200E3 ZZ: ResetInput1 BitDPT.1CW
201E3 ZZ: StopInput1 BitDPT.1CW
210E3 DisableInput1 BitDPT.1CW
212E4 Switching sensorOutput1 BitDPT.1CWT
212E4 Alarm sensorOutput1 BitDPT.1CWT
212E4 SwitchingOutput1 BitDPT.1CWT
212E4 Blind UP/DOWNOutput1 BitDPT.1CWT
212E4 Switch (event 0)Output1 BitDPT.1CT
212E4 Priority (event 0)Output2 BitDPT.2CT
212E4 1-byte value (-128 to 127) (event 0)Output1 ByteDPT.6CT
212E4 1-byte value (0 to 255) (event 0)Output1 ByteDPT.5CT
212E4 Scene (event 0)Output1 ByteDPT.18CT
212E4 2-byte value (-32,768 to 32,767) (event 0)Output2 BytesDPT.8CT
212E4 2-byte value (0 to 65,535) (event 0)Output2 BytesDPT.7CT
212E4 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0)Output4 BytesDPT.13CT
212E4 4-byte value (0 to 4294967295) (event 0)Output4 BytesDPT.12CT
212E4 2-byte floating point (event 0)Output2 BytesDPT.9CT
212E4 SceneOutput1 ByteDPT.18CWTU
212E4 Switching step 1Output1 BitDPT.1CWT
212E4 Switching 1 actuationOutput1 BitDPT.1CWT
212E4 HZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
212E4 HZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
212E4 HZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
212E4 HZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
212E4 HZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
212E4 Output valueOutput2 BytesDPT.9CT
213E4 DimmingOutput4 BitDPT.3CT
213E4 STOP/slat adjustmentOutput1 BitDPT.1CT
213E4 Switch (event 1)Output1 BitDPT.1CT
213E4 Priority (event 1)Output2 BitDPT.2CT
213E4 1-byte value (-128 to 127) (event 1)Output1 ByteDPT.6CT
213E4 1-byte value (0 to 255) (event 1)Output1 ByteDPT.5CT
213E4 Scene (event 1)Output1 ByteDPT.18CT
213E4 2-byte value (-32,768 to 32,767) (event 1)Output2 BytesDPT.8CT
213E4 2-byte value (0 to 65,535) (event 1)Output2 BytesDPT.7CT
213E4 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1)Output4 BytesDPT.13CT
213E4 4-byte value (0 to 4294967295) (event 1)Output4 BytesDPT.12CT
213E4 2-byte floating point (event 1)Output2 BytesDPT.9CT
213E4 Switching step 2Output1 BitDPT.1CWT
213E4 Switching 2 actuationsOutput1 BitDPT.1CWT
213E4 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
213E4 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
213E4 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
213E4 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
213E4 ZZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
213E4 Request output valueInput1 BitDPT.1CW
214E4 Start event 0/1Input1 BitDPT.1CW
214E4 Top end positionInput1 BitDPT.1CW
214E4 Scene storage displayOutput1 BitDPT.1CT
214E4 Switching step 3Output1 BitDPT.1CWT
214E4 Switching 3 actuationsOutput1 BitDPT.1CWT
214E4 HZ: Request counter readingInput1 BitDPT.1CW
214E4 Measured value outside of rangeOutput1 BitDPT.1CT
215E4 Bottom end positionInput1 BitDPT.1CW
215E4 Switching step 4Output1 BitDPT.1CWT
215E4 Switching 4 actuationsOutput1 BitDPT.1CWT
215E4 HZ: Limit value exceededOutput1 BitDPT.1CT
215E4 Heating temperature limitOutput1 BitDPT.1CT
216E4 Save sceneInput1 BitDPT.1CW
216E4 Enable saveInput1 BitDPT.1CW
216E4 Switching step 5Output1 BitDPT.1CWT
216E4 Switching, long actuationOutput1 BitDPT.1CWT
216E4 Bit threshold value 1Output1 BitDPT.1CT
216E4 Byte threshold value 1Output1 ByteDPT.5CT
216E4 2-byte threshold value 1Output2 BytesDPT.7CT
216E4 Temperature threshold value 1Output2 BytesDPT.9CT
217E4 Switch step UP/DOWNInput1 BitDPT.1CW
217E4 ZZ: Limit value exceededOutput1 BitDPT.1CT
217E4 Send if threshold value 1 undershotInput1 ByteDPT.5CW
217E4 Send if threshold value 1 undershotInput2 BytesDPT.7CW
217E4 Send if threshold value 1 undershotInput2 BytesDPT.9CW
218E4 Actuating numberInput1 ByteDPT.5CWTU
218E4 ZZ: Request counter readingInput1 BitDPT.1CW
218E4 Send if threshold value 1 exceededInput1 ByteDPT.5CW
218E4 Send if threshold value 1 exceededInput2 BytesDPT.7CW
218E4 Send if threshold value 1 exceededInput2 BytesDPT.9CW
219E4 ZZ: Reverse directionInput1 BitDPT.1CW
220E4 ZZ: ResetInput1 BitDPT.1CW
220E4 Change temperature, tolerance band 1 lower limitInput2 BytesDPT.9CW
221E4 ZZ: StopInput1 BitDPT.1CW
221E4 Change temperature, tolerance band 1 upper limitInput2 BytesDPT.9CW
222E4 Bit threshold value 2Output1 BitDPT.1CT
222E4 Byte threshold value 2Output1 ByteDPT.5CT
222E4 2-byte threshold value 2Output2 BytesDPT.7CT
222E4 Temperature threshold value 2Output2 BytesDPT.9CT
223E4 Send if threshold value 2 undershotInput1 ByteDPT.5CW
223E4 Send if threshold value 2 undershotInput2 BytesDPT.7CW
223E4 Send if threshold value 2 undershotInput2 BytesDPT.9CW
224E4 Send if threshold value 2 exceededInput1 ByteDPT.5CW
224E4 Send if threshold value 2 exceededInput2 BytesDPT.7CW
224E4 Send if threshold value 2 exceededInput2 BytesDPT.9CW
226E4 Change temperature, tolerance band 2 lower limitInput2 BytesDPT.9CW
227E4 Change temperature, tolerance band 2 upper limitInput2 BytesDPT.9CW
230E4 DisableInput1 BitDPT.1CW
232E5 Switching sensorOutput1 BitDPT.1CWT
232E5 Alarm sensorOutput1 BitDPT.1CWT
232E5 SwitchingOutput1 BitDPT.1CWT
232E5 Blind UP/DOWNOutput1 BitDPT.1CWT
232E5 Switch (event 0)Output1 BitDPT.1CT
232E5 Priority (event 0)Output2 BitDPT.2CT
232E5 1-byte value (-128 to 127) (event 0)Output1 ByteDPT.6CT
232E5 1-byte value (0 to 255) (event 0)Output1 ByteDPT.5CT
232E5 Scene (event 0)Output1 ByteDPT.18CT
232E5 2-byte value (-32,768 to 32,767) (event 0)Output2 BytesDPT.8CT
232E5 2-byte value (0 to 65,535) (event 0)Output2 BytesDPT.7CT
232E5 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0)Output4 BytesDPT.13CT
232E5 4-byte value (0 to 4294967295) (event 0)Output4 BytesDPT.12CT
232E5 2-byte floating point (event 0)Output2 BytesDPT.9CT
232E5 SceneOutput1 ByteDPT.18CWTU
232E5 Switching step 1Output1 BitDPT.1CWT
232E5 Switching 1 actuationOutput1 BitDPT.1CWT
232E5 HZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
232E5 HZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
232E5 HZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
232E5 HZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
232E5 HZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
233E5 DimmingOutput4 BitDPT.3CT
233E5 STOP/slat adjustmentOutput1 BitDPT.1CT
233E5 Switch (event 1)Output1 BitDPT.1CT
233E5 Priority (event 1)Output2 BitDPT.2CT
233E5 1-byte value (-128 to 127) (event 1)Output1 ByteDPT.6CT
233E5 1-byte value (0 to 255) (event 1)Output1 ByteDPT.5CT
233E5 Scene (event 1)Output1 ByteDPT.18CT
233E5 2-byte value (-32,768 to 32,767) (event 1)Output2 BytesDPT.8CT
233E5 2-byte value (0 to 65,535) (event 1)Output2 BytesDPT.7CT
233E5 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1)Output4 BytesDPT.13CT
233E5 4-byte value (0 to 4294967295) (event 1)Output4 BytesDPT.12CT
233E5 2-byte floating point (event 1)Output2 BytesDPT.9CT
233E5 Switching step 2Output1 BitDPT.1CWT
233E5 Switching 2 actuationsOutput1 BitDPT.1CWT
233E5 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.6CT
233E5 ZZ: Counter reading 1-byte valueOutput1 ByteDPT.5CT
233E5 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.8CT
233E5 ZZ: Counter reading 2-byte valueOutput2 BytesDPT.7CT
233E5 ZZ: Counter reading 4-byte valueOutput4 BytesDPT.13CT
234E5 Start event 0/1Input1 BitDPT.1CW
234E5 Top end positionInput1 BitDPT.1CW
234E5 Scene storage displayOutput1 BitDPT.1CT
234E5 Switching step 3Output1 BitDPT.1CWT
234E5 Switching 3 actuationsOutput1 BitDPT.1CWT
234E5 HZ: Request counter readingInput1 BitDPT.1CW
235E5 Bottom end positionInput1 BitDPT.1CW
235E5 Switching step 4Output1 BitDPT.1CWT
235E5 Switching 4 actuationsOutput1 BitDPT.1CWT
235E5 HZ: Limit value exceededOutput1 BitDPT.1CT
236E5 Save sceneInput1 BitDPT.1CW
236E5 Enable saveInput1 BitDPT.1CW
236E5 Switching step 5Output1 BitDPT.1CWT
236E5 Switching, long actuationOutput1 BitDPT.1CWT
237E5 Switch step UP/DOWNInput1 BitDPT.1CW
237E5 ZZ: Limit value exceededOutput1 BitDPT.1CT
238E5 Actuating numberInput1 ByteDPT.5CWTU
238E5 ZZ: Request counter readingInput1 BitDPT.1CW
239E5 ZZ: Reverse directionInput1 BitDPT.1CW
240E5 ZZ: ResetInput1 BitDPT.1CW
241E5 ZZ: StopInput1 BitDPT.1CW
250E5 DisableInput1 BitDPT.1CW
252CO2: absolute air pressure [Pa]Input2 BytesDPT.9CW
Parameters (463)
ParameterTypeDefault
Send in operationlistinactive
Send 'in operation' cyclicallylistevery minute
Send delay after bus voltage recoveryunsignedInt 2…2552
PID_HARDWARE_TYPE_PARAMETERlist
PAR_TARGETlistGS41_10_SND
PAR_CO2_CHANNEL_ACTIVElistactive
PAR_CO2_AMPEL_USElistinactive
PAR_CO_CHANNEL_ACTIVElistinactive
PAR_CO_AMPEL_USElistinactive
PAR_FD_CHANNEL_ACTIVElistactive
PAR_FD_AMPEL_USElistinactive
PAR_VOC_CHANNEL_ACTIVElistactive
PAR_VOC_AMPEL_USElistinactive
PAR_RH_CHANNEL_ACTIVElistactive
PAR_RH_AMPEL_USElistinactive
PAR_T_CHANNEL_ACTIVElistactive
PAR_T_AMPEL_USElistinactive
PAR_DEWPOINT_CHANNEL_ACTIVElistactive
PAR_PRESSURE_CHANNEL_ACTIVElistactive
PAR_VAV_CHANNEL_ACTIVElistactive
PAR_INPUT_CHANNEL_ACTIVElistactive
PAR_OUTPUT_CHANNEL_ACTIVElistinactive
PAR_TOUCH_CHANNEL_ACTIVElistactive
CO2 sensorlistenabled
Value offsetlist0 ppm
PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_30unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_30unsignedInt 0…2551
Error CO2 sensorlistdon't notify
PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_40unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_40unsignedInt 0…2551
Enable calibration via buslistno
PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_50unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_50unsignedInt 0…2551
Send CO2 value when changinglistdisabled
Send CO2 value cyclicallylistevery minute
external valueunsignedInt 0…2550
percentageunsignedInt 0…2550
PAR_DUMMY_PB_SENSOR_0_SETTINGSBLOCK_70unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_0_SETTINGSBLOCK_70unsignedInt 0…2551
Send CO2 min/max values when changinglistdisabled
Send CO2 min/max values cyclicallylistdisabled
Air pressure compensation of CO2 sensorlistcompensation with internal air pressure value
Altitude a. s. l.unsignedInt 0…5000700
Type of CO2 controllistdisabled
PAR_CTL_0_ACTlistdisabled
PAR_CTL_0_VIS_STEP1listdisabled
PAR_CTL_0_VIS_STEP2listdisabled
PAR_CTL_0_VIS_STEP3listdisabled
PAR_CTL_0_VIS_ONE_STEPlistdisabled
PAR_CTL_0_SEND_CYCLIC_ACTlistdisabled
Allow to change base set-point via buslistno
Hysteresis (symmetrical)list50 ppm
Control value output formatlistpercent
Control value output formatlistswitching command
PAR_CTL_0_ACTUATING_VAL_FORMATlistswitching command
PAR_CTL_0_OUT_GO_NUMBERunsignedInt 0…2550
PAR_CTL_0_SEND_BY_CHANGE_FORMATunsignedInt 0…2550
Sensor value 1listinternal sensor
Sensor value 2listdisabled
Sensor value 3listdisabled
Sensor value 4listdisabled
PAR_CTL_0_EXT_VALUE_CALC_TYPE_ACTlistdisabled
Value calculation typelistAverage
Weight value 1unsignedInt 0…101
Weight value 2unsignedInt 0…101
Weight value 3unsignedInt 0…101
Weight value 4unsignedInt 0…101
CO2 threshold 1list400 ppm
Switching command below threshold 1listoff
Switching command above threshold 1liston
Control value in case of sensor errorlistoff
Priority below threshold 1liststop priority
Priority above threshold 1liston with priority
Control value in case of sensor errorliststop priority
Blocking objectlistdisabled
Behavior when unblockinglistdon't send
Behavior when blockinglistdon't send
Switching command when blockinglistoff
Priority when blockingliststop priority
CO2 threshold 2listthreshold 1 + 400 ppm
Switching command below threshold 2listoff
Switching command above threshold 2liston
Priority below threshold 2liststop priority
Priority above threshold 2liston with priority
CO2 threshold 3listthreshold 2 + 400 ppm
Switching command below threshold 3listoff
Switching command above threshold 3liston
Priority below threshold 3liststop priority
Priority above threshold 3liston with priority
Value when below threshold 1unsignedInt 0…2550
Percent below threshold 1unsignedInt 0…1000
Scene below threshold 1unsignedInt 1…641
PercentunsignedInt 0…1000
ValueunsignedInt 0…2550
SceneunsignedInt 1…641
Control value in case of sensor errorunsignedInt 0…2550
Control value in case of sensor errorlist0%
Scene in case of sensor errorunsignedInt 1…641
Percent when blockingunsignedInt 0…1000
Value when blockingunsignedInt 0…2550
Scene when blockingunsignedInt 1…641
Set-pointlist400 ppm
Proportional bandlist500 ppm
Reset timelist15 min.
Min. control valuelist0%
Min. control valuelist0
Max. control valuelist100%
Max. control valuelist255
Send control value when change-overlistdisabled
Send control value when changinglistdisabled
send control value cyclicallylistevery minute
Relative humidity sensorlistdisabled
Value offsetlist0%
PAR_DUMMY_PB_SENSOR_1_SETTINGSBLOCK_30unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_1_SETTINGSBLOCK_30unsignedInt 0…2551
Error humidity sensorlistdon't notify
PAR_SENSOR_1_BUS_CALIBRATION_USElistno
PAR_DUMMY_PB_SENSOR_1_SETTINGSBLOCK_50unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_1_SETTINGSBLOCK_50unsignedInt 0…2551
Send relative humidity when changinglistdisabled
Send relative humidity cyclicallylistevery minute
PAR_DUMMY_PB_SENSOR_1_SETTINGSBLOCK_70unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_1_SETTINGSBLOCK_70unsignedInt 0…2551
Send rH min/max values when changinglistdisabled
Send rH min/max values cyclicallylistdisabled
Control typelistdisabled
PAR_CTL_1_ACTlistdisabled
PAR_CTL_1_VIS_STEP1listdisabled
PAR_CTL_1_VIS_STEP2listdisabled
PAR_CTL_1_VIS_STEP3listdisabled
PAR_CTL_1_VIS_ONE_STEPlistdisabled
PAR_CTL_1_SEND_CYCLIC_ACTlistdisabled
Hysteresis (symmetrical)list5%
PAR_CTL_1_ACTUATING_VAL_FORMATlistswitching command
PAR_CTL_1_OUT_GO_NUMBERunsignedInt 0…2550
PAR_CTL_1_SEND_BY_CHANGE_FORMATunsignedInt 0…2550
PAR_CTL_1_EXT_VALUE_CALC_TYPE_ACTlistdisabled
rH threshold 1list20%
rH threshold 2listthreshold 1 + 10%
rH threshold 3listthreshold 2 + 10%
Set-pointlist30%
Proportional bandlist20%
Send control value cyclicallylistevery minute
Comparatorlistdisabled
Value 1listinternal sensor
Value 2listabsolute humidity in [g/m3] via bus (communication object)
Output when Value 1 < Value 2list0 (unblock)
Output when errorlist1 (block)
Send output value when changinglistdisabled
Send output value cyclicallylistevery minute
Temperature sensorlistdisabled
Value offsetsignedInt -50…500
PAR_DUMMY_PB_SENSOR_2_SETTINGSBLOCK_30unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_2_SETTINGSBLOCK_30unsignedInt 0…2551
Error temperature sensorlistdon't notify
PAR_SENSOR_2_BUS_CALIBRATION_USElistno
PAR_DUMMY_PB_SENSOR_2_SETTINGSBLOCK_50unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_2_SETTINGSBLOCK_50unsignedInt 0…2551
Send temperature when changinglistdisabled
Send temperature cyclicallylistevery minute
External valueunsignedInt 0…2550
PercentageunsignedInt 0…2550
PAR_DUMMY_PB_SENSOR_2_SETTINGSBLOCK_70unsignedInt 0…2551
PAR_DUMMY_HELP_PB_SENSOR_2_SETTINGSBLOCK_70unsignedInt 0…2551
Send min/max temperature values when changinglistdisabled
Send min/max temperature values cyclicallylistdisabled
Frost alarmlistdisabled
Frost alarm when temperaturelist<1°C
Send frost alarm when change of statuslistdisabled
Send frost alarm cyclicallylistdisabled
Heat alarmlistdisabled
Heat alarm when temperaturelist>30°C
Send heat alarm when change of statuslistdisabled
Send heat alarm cyclicallylistdisabled
Select heating and/or coolinglistinactive
PAR_RTR_ACTlistdisabled
PAR_RTR_ACT_MAIN_ST_HEATlistdisabled
PAR_RTR_ACT_MAIN_ST_COOLlistdisabled
PAR_DUMMY_PB_RTR_CONFIGBLOCK_30unsignedInt 0…2551
PAR_DUMMY_HELP_PB_RTR_CONFIGBLOCK_30unsignedInt 0…2551
Extra level heating enablelistdisabled
Guide heatinglistdisabled
Heating demand for displaylistno
Extra level cooling enablelistdisabled
Guide coolinglistdisabled
Cooling demand for displaylistno
Operating mode after resetlistComfort
Operating mode after ETS-downloadlistComfort
PAR_RTR_GUIDING_ACTlistdisabled
Comfort temperatureunsignedInt 0…400210
Standby setback heating below Comfort temp.unsignedInt 0…1000
Eco setback heating below Comfort temp.unsignedInt 0…1000
Frost protection temperature heatingunsignedInt 0…40070
Standby increment cooling above Comfort temp. (plus Dead zone)unsignedInt 0…1000
Eco increment cooling above Comfort temp. (plus Dead zone)unsignedInt 0…1000
Heat protection temperature coolingunsignedInt 0…400350
Interval to main level heatingsignedInt -100…0-10
Interval to main level coolingunsignedInt 0…10010
Send set-point temperature when changinglistdisabled
Send set-point temperature cyclicallylistdisabled
PAR_DUMMY_PB_RTR_SET_TEMP_L2BLOCK_30unsignedInt 0…2551
PAR_DUMMY_HELP_PB_RTR_SET_TEMP_L2BLOCK_30unsignedInt 0…2551
Toggle between heating and coolinglistAutomatically (via controller)
Dead zone between heating and coolingunsignedInt 0…10020
Min. guide value heatingsignedInt -50…500
Max. guide value heatingsignedInt -50…500
Max. increment of set-point for min. guide value heatingsignedInt 0…100
Min. guide value coolingsignedInt -50…500
Max. guide value coolingsignedInt -50…500
Max. setback of set-point for max. guide value coolingsignedInt 0…100
Set-point overridelistdisabled
Blocking object heating mode: enablelistdisabled
Blocking object cooling mode: enablelistdisabled
Blocking object extra level heating: enablelistdisabled
Blocking object extra level cooling: enablelistdisabled
Temperature measurement value 1listinternal sensor
Temperature measurement value 2listdisabled
Temperature measurement value 3listdisabled
Temperature measurement value 4listdisabled
PAR_RTR_EXT_VALUE_CALC_TYPE_ACTlistdisabled
Man. adjustment rangelist+/-3K
LED's when disabledlistall LED's off
LED's when blockedlistall LED's off
Send man. offset upon changelistdisabled
Send man. offset cyclicallylistdisabled
Party function aktivatelistdisabled
Mode when party function activlistComfort mode
Duration activatelistenabled
DurationunsignedInt 1…144060
Retriggerlistdisabled
Control typelistPI
Control direction of control valuelistnormal
Proportional bandunsignedInt 1…85
Hysteresis (symmetrical)unsignedInt 5…505
PWM cycleunsignedInt 5…305
Control value in case of sensor error (0…255)unsignedInt 0…2550
PAR_SEP_RTR_MAIN_ST_HEAT_40unsignedInt 0…2551
Send control value when changinglistenabled
Send control value when blockedlistdon't send
Control value when blockedlist0%
Control value when blockedunsignedInt 0…2550
Control value when blockedlistoff
PAR_SEP_RTR_EXTRA_ST_HEAT_40unsignedInt 0…2551
PAR_SEP_RTR_MAIN_ST_COOL_40unsignedInt 0…2551
PAR_SEP_RTR_EXTRA_ST_COOL_40unsignedInt 0…2551
Dew point sensorlistdisabled
Send dew point temp. when changinglistdisabled
Send dew point temp. cyclicallylistevery minute
Dew point alarmlistdisabled
Dew point alarm advancelist1K
Dew point alarm hysteresis (symmetrical)list1K hysteresis
Send dew point alarm when change of statuslistdisabled
Send dew point alarm cyclicallylistdisabled
Type of telegram for dew point alarmlistswitching command
Switching command when dew point alarmlistoff
Priority when dew point alarmliststop priority
Percent when dew point alarm (0…100%)unsignedInt 0…1000
Value when dew point alarm (0…255)unsignedInt 0…2550
Scene when dew point alarm (1...64)unsignedInt 1…641
Switching command at the end of dew point alarmlistoff
Priority at the end of dew point alarmliststop priority
Percent at the end of dew point alarm (0…100%)unsignedInt 0…1000
Value at the end of dew point alarm (0…255)unsignedInt 0…2550
Scene at the end of dew point alarm (1…64)unsignedInt 1…641
Air pressure sensorlistdisabled
Error air pressure sensorlistdon't notify
Send absolute air pressure when changinglistdisabled
Send absolute air pressure cyclicallylistevery minute
Send relative air pressure when changinglistdisabled
Send relative air pressure cyclicallylistevery minute
PAR_P_ACT_PRELlistdisabled
PAR_VAVC_PLUS_0_VIEWlistdisabled
Second VAV parameter setlistinactive
PAR_VAVC_PLUS_0_ACTlistdisabled
PAR_VAVC_PLUS_0_MAIN_HEAT_VISIBLElistdisabled
PAR_VAVC_PLUS_0_MAIN_COOL_VISIBLElistdisabled
PAR_VAVC_PLUS_0_EXTRA_HEAT_VISIBLElistdisabled
PAR_VAVC_PLUS_0_EXTRA_COOL_VISIBLElistdisabled
PAR_VAVC_PLUS_0_EXTERN_0_VISIBLElistdisabled
PAR_DUMMY_PB_VAVC_PLUS_0_SETTINGSBLOCK_SET_0unsignedInt 0…2551
PAR_DUMMY_HELP_PB_VAVC_PLUS_0_SETTINGSBLOCK_SET_0unsignedInt 0…2551
CO2 control includelistdisabled
Relative humidity control includelistdisabled
Main level heating includelistdisabled
Extra level heating includelistdisabled
Main level cooling includelistdisabled
Extra level cooling includelistdisabled
External object includelistdisabled
PAR_DUMMY_PB_VAVC_PLUS_0_SETTINGSBLOCK_SET_1unsignedInt 0…2551
PAR_DUMMY_HELP_PB_VAVC_PLUS_0_SETTINGSBLOCK_SET_1unsignedInt 0…2551
PAR_SEP_VAVC_PLUS_0_30unsignedInt 0…2551
PAR_SEP_VAVC_PLUS_0_30_WENN_CHOOSEunsignedInt 0…2551
Send VAVC control value when changinglistdisabled
Send VAVC control value cyclicallylistevery minute
PAR_SEP_VAVC_PLUS_0_40unsignedInt 0…2551
PAR_SEP_VAVC_PLUS_0_40_WENN_CHOOSEunsignedInt 0…2551
Percent when blocking (0…100%)unsignedInt 0…1000
Value when blocking (0…255)unsignedInt 0…2550
Limit number of telegramslistinactive
Maximum number of sent telegramsunsignedInt 1…25520
Maximum number of sent telegrams perlist1 s
Designationtext
Functionlistinactive
Binary functionlistSwitching/alarm
Switching/alarm sensorlistSwitch
Communication object DPT 1.001text<---
Communication object DPT 1.005text<---
Differentiation between short and long actuationlistinactive
Contact opening -> event 0 contact closing -> event 1text<---
Short actuation -> event 0 long actuation -> event 1text<---
Long actuation from ... slist0,4
Activate minimum signal durationlistinactive
At contact opening in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
At contact closing in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
Query input after download, ETS reset and bus voltage recoverylistinactive
Inactive waiting time after bus voltage recovery in s (0 - 30,000)unsignedInt 0…300000
Input is being actuatedlistclosed
Enable object 'Start event 0/1'listinactive
Reaction in case of event 0listOff/alarm
Reaction in case of event 1listOn/no alarm
Cyclical sendinglistinactive
Telegram repeated every ... sunsignedInt 1…6553560
at object valuelistOn
Debouncing time ... mslist50
Enable object 'Disable'listinactive
Switching/dimming sensorlistDimmer/switch
At actuation: dimming directionlistSwitchover
At short actuation: switchinglistSwitchover
At long actuation: dimming directionlistSwitchover after switching darker
Dimming procedurelistStart/stop
Brightness change per sent telegramlist3,13%
Telegram repeated every ... slist0,4
Blind operating functionlist2-push-button, standard
Brief actuation: STOP/stepwise Long actuation: move UP/DOWNtext<---
Short actuation: move UP/DOWN Long actuation: STOP/stepwisetext<---
One after another at actuation UP, STOP, DOWN, STOPtext<---
At actuation: move UP/DOWN STOP at end of actuationtext<---
At actuation: move UP/DOWN STOP at next actuationtext<---
At actuation: slattext<---
Reaction at short actuationlistStop/slat OPEN
Reaction at long actuationlistUp
Reaction at actuationlistUp
Reaction at actuationlistStop/slat OPEN
'Slat' telegram repeated every ... slist0,4
'Slat' telegram repeated, every ... slist0,4
Reaction in case of event 0list1-byte value (0 to 255)
Sent valuelistOn
Valuelist0
Sent valuesignedInt -128…1270
Sent valueunsignedInt 0…2550
Sent valueunsignedInt 1…641
Forced operationlistOff
Sent valuesignedInt -32768…327670
Sent valueunsignedInt 0…655350
Sent valuesignedInt -2147483648…21474836470
Sent valueunsignedInt 0…42949672950
Sent valuefloat -670760.96…670433.2820
Reaction in case of event 1list1-byte value (0 to 255)
Sent valuelistOff
Scene number at actuationunsignedInt 1…641
Save scenelistno
Long actuation from ... slist3
Number of stepslist3
Switching sequence typelistActivate/deactivate (one button)
Direction at actuationlistswitch up
Switching sequence like ...000>001>011>111>011>...text<---
Switching sequence like 000>001>011>111text<---
Switching sequence like ...000>001>011>010>110>...text<---
At contact opening in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
At contact closing in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
Max. number of actuationslist3
Sent valuelistSwitchover
Update and send at actuationlistinactive
Maximum time between two actuations ... slist0,5
Additional object for long actuationlistinactive
Sent value at long actuationlistSwitchover
Data type (main counter)list4-byte value (-2,147,483,648 to 2,147,483,647)
Communication object DPT 6.010text<---
Communication object DPT 5.010text<---
Communication object DPT 8.001text<---
Communication object DPT 7.001text<---
Communication object DPT 13.001text<---
Limit value 1signedInt -128…1270
Limit value 2signedInt -128…127127
Limit value 1unsignedInt 0…2550
Limit value 2unsignedInt 0…255255
Limit value 1signedInt -32768…327670
Limit value 2signedInt -32768…3276732767
Limit value 1unsignedInt 0…655350
Limit value 2unsignedInt 0…6553565535
Limit value 1signedInt -2147483648…21474836470
Limit value 2signedInt -2147483648…21474836472147483647
Counting typelistonly in case of rising edge
Number of input pulses for a counting pulseunsignedInt 1…100001
Counter reading change per counting pulsesignedInt -10000…100001
Send counter reading at download, ETS reset and bus voltage recoverylistinactive
Send counter reading at changelistinactive
Counter reading is sent, everylistinactive
Save counter readinglistinactive
Reset counter reading at downloadlistinactive
Enable intermediate counterlistinactive
Data type (intermediate counter)list4-byte value (-2,147,483,648 to 2,147,483,647)
Behaviour if a limit value is exceeded/undershotlistcontinue counting
Reverse counting directionlistinactive
Sensor typelist1-10 V
Lower measuring limit in x% of effective rangeunsignedInt 0…1000
Upper measuring limit in x% of effective rangeunsignedInt 0…100100
Output valuelist4-byte floating point
Output value to be sent at lower measuring limitsignedInt -128…127-128
Output value to be sent at lower measuring limitunsignedInt 0…2550
Output value to be sent at lower measuring limitsignedInt -32768…32767-32768
Output value to be sent at lower measuring limitunsignedInt 0…655350
Output value to be sent at lower measuring limitfloat -670760.96…670433.280
Output value to be sent at lower measuring limitfloat -3.4028234e+38…3.4028234e+380
Output value to be sent at upper measuring limitsignedInt -128…127127
Output value to be sent at upper measuring limitunsignedInt 0…255255
Output value to be sent at upper measuring limitsignedInt -32768…3276732767
Output value to be sent at upper measuring limitunsignedInt 0…6553565535
Output value to be sent at upper measuring limitfloat -670760.96…670433.280
Output value to be sent at upper measuring limitfloat -3.4028234e+38…3.4028234e+380
Filterslistinactive
Output value is sent from x% change in output rangelistif change above 2%
Output value is sent, everylistinactive
Use threshold valuelistinactive
Send threshold at changelistenabled
Send if threshold value undershot, everylistinactive
Send if threshold value exceeded, everylistinactive
Tolerance band lower limit in x% of output rangeunsignedInt 0…1000
Tolerance band upper limit in x% of output rangeunsignedInt 0…100100
Limit value changeable via buslistinactive
Data type of threshold value objectlist1 bit
Send if threshold value undershotlistSend OFF telegram
Send if threshold value exceededlistSend ON telegram
Minimum duration of undershootlistinactive
Minimum duration of overshootlistinactive
Send if threshold value undershotunsignedInt 0…2550
Send if threshold value exceededunsignedInt 0…2550
Send if threshold value undershotunsignedInt 0…655350
Send if threshold value exceededunsignedInt 0…655350
Send if threshold value undershot [0.1°C]signedInt -500…15000
Send if threshold value exceeded [0.1°C]signedInt -500…15000
Suppression stagelistweak
E4/5 Temperature functionlistTemperature
Temperature sensor typelistPT1000
Temperature offset in Klist0
Line fault compensationlistNone
Line length, single distance ... in munsignedInt 1…3010
Cross-section of the busbar, value * 0.01 mm2unsignedInt 1…150100
Line resistance in milliohm [sum of feed and return conductors]unsignedInt 0…10000500
Output value sent from a change of [x 0.1°C]listdisabled
Heatlistactive
Value [°C]unsignedInt 10…6035
Hysteresis [°C]list1,5
Enable threshold value 1 functionlistinactive
Enable threshold value 2 functionlistinactive
Tolerance band lower limit [0.1°C]signedInt -500…1500-500
Tolerance band upper limit [0.1°C]signedInt -500…15001500
Send if threshold value undershotlistSend ON telegram
Send if threshold value undershot [0.1°C]signedInt -500…15000
Send if threshold value exceeded [0.1°C]signedInt -500…15000
Send if threshold value undershotlistdisabled
Send if threshold value exceededlistdisabled
Limits changeable via buslistinactive

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Multisensor 4217/1.0a 1.0 latest$42170ABC2026-11-25491 KBDownload
Multisensor 4217/1.0a 1.0$42170ABC2026-11-25491 KBDownload

About this file

This is the official ETS product database for the Schneider Electric Industries SAS Air Quality Multisensor (MTN6005-0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.