Thermostat STD WRKT3300XXX/WRKT3400XXX
Panasonic · Order number WRKT3300XXX/WRKT3400XXX · HVAC › Thermostat
Room Thermostat - Standart
Download .knxprod Thermostat STD 0.1 · 73 KB
Product
| Manufacturer | Panasonic |
|---|---|
| Product name | Thermostat STD |
| Order number | WRKT3300XXX/WRKT3400XXX |
| Hardware | HW Thermostat STD |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | No |
| Registration | Certified · 2016-08-12 |
| Languages | en-US, de-DE |
| Catalog entry | M-008B_H-805431.2DP-1_HP-0203-01-A98B_CI-WRKT3300XXX.2FWRKT3400XXX.20-1 |
| Fingerprint | A98B |
| SHA-256 | 08aea3e952d9340ad92c8bca6f308940808efce1be9fa340eeeae4e4d727e7a3 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Thermostat STD 0.1
| Application number | $0203 |
|---|---|
| Version | 0.1 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 54 |
| Group objects | 32 |
Group objects (32)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Actual temperature value | Transmit actual value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 1 | Current operation mode | Indicate operation mode | 1 Byte | CRWT | |
| 2 | Presence Input | Input for presence signal | 1 Bit | 1.1 switch | CRW |
| 3 | Window State | Input for window contact | 1 Bit | 1.1 switch | CRW |
| 4 | Heating base setpoint | Define set point value | 2 Bytes | 9.1 temperature (°C) | CRW |
| 5 | Cooling base setpoint | Define set point value | 2 Bytes | 9.1 temperature (°C) | CRW |
| 6 | Current Setpoint | Indicate/adjust set point | 2 Bytes | 9.1 temperature (°C) | CRWT |
| 7 | Heating Switching Control Value | Transmit actuating value | 1 Bit | 1.1 switch | CRT |
| 7 | Heating Continuous Control Value | Transmit actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | Cooling Switching Control Value | Transmit actuating value | 1 Bit | 1.1 switch | CRT |
| 8 | Cooling Continuous Control Value | Transmit actuating value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 9 | Switchover between heating and cooling | heating=1, cooling=0 | 1 Bit | 1.1 switch | CRWT |
| 9 | Report heating or cooling mode | heating=1 cooling=0 | 1 Bit | 1.1 switch | CRT |
| 10 | Reset manual operations | Reset=1 | 1 Bit | 1.1 switch | CRW |
| 11 | Fan mode (manual/auto) | 1=manual, 0=auto | 1 Bit | 1.1 switch | CRWT |
| 11 | Fan mode (manual/auto) | 0=manual, 1=auto | 1 Bit | 1.1 switch | CRWT |
| 12 | Fan level | send/receive fan level 0-100 % | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 12 | Fan level | send/receive fan level 0-3 | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 13 | LCD backlight | on/off backlight | 1 Bit | 1.1 switch | CRW |
| 14 | Time | Receive time | 3 Bytes | 10.1 time of day | CRW |
| 15 | Time query | Request for time | 1 Bit | 1.2 boolean | CRT |
| 16 | Date | Receive date | 3 Bytes | 11.1 date | CRW |
| 17 | Date query | Request for date | 1 Bit | 1.2 boolean | CRT |
| 18 | Switching program lock | Lock=1 | 1 Bit | 1.1 switch | CRW |
| 19 | Heating PWM Control Value | Transmit actuating value | 1 Bit | 1.1 switch | CRT |
| 20 | Cooling PWM Control Value | Transmit actuating value | 1 Bit | 1.1 switch | CRT |
| 21 | Fan level | send/receive fan level 1 | 1 Bit | 1.1 switch | CRWTU |
| 22 | Fan level | send/receive fan level 2 | 1 Bit | 1.1 switch | CRWTU |
| 23 | Fan level | send/receive fan level 3 | 1 Bit | 1.1 switch | CRWTU |
| 24 | Fan unit | send on/off | 1 Bit | 1.1 switch | CT |
| 29 | Object 29 | debug 1 | 1 Byte | 5.10 counter pulses (0..255) | CRWTU |
| 30 | Object 30 | debug 2 | 1 Byte | 5.10 counter pulses (0..255) | CRWTU |
Parameters (53)
| Parameter | Type | Default |
|---|---|---|
| Operation mode after reset | list | Standby |
| Control function | list | Heating |
| Control function after ETS download | list | Heating |
| Transmit actual temperature at change | list | inactive |
| Transmit actual temperature cyclically | list | not cyclically, only at change |
| Heating setpoint base | unsignedInt 15…32 | 20 |
| Heating reduction standby | unsignedInt 1…10 | 3 |
| Heating reduction night | unsignedInt 1…10 | 5 |
| Heating setpoint frost protection | unsignedInt 1…15 | 5 |
| Cooling setpoint base | unsignedInt 15…32 | 20 |
| Cooling increase standby | unsignedInt 1…10 | 3 |
| Cooling increase night | unsignedInt 1…10 | 5 |
| Cooling setpoint heat protection | unsignedInt 30…40 | 37 |
| Minimum distance between heating and cooling | list | 1K |
| Transmit current setpoint cyclically | list | not cyclically, only at change |
| Heating trasmit control value cyclically | list | not cyclically, only at change |
| Heating controller type | list | 2 Step |
| Heating hysteresis | list | 0.2K |
| Heating control value invert | list | yes |
| Heating PI parameter type | list | Via type of system |
| Heating type of the system | list | Warm water heating |
| Heating PWM cyclic time (Min) | unsignedInt 1…60 | 1 |
| Heating propotional band | list | 4.0K |
| Transmit control value at change of | list | % 5 |
| Cooling integral reset time | unsignedInt 0…250 | 0 |
| Cooling propotional band | list | 4.0K |
| Cooling PWM cyclic time (Min) | unsignedInt 1…60 | 1 |
| Cooling type of the system | list | Cool ceiling |
| Cooling PI parameter type | list | Via type of system |
| Cooling control value invert | list | yes |
| Cooling hysteresis | list | 0.2K |
| Cooling controller type | list | 2 Step |
| Cooling transmit control value cyclically | list | not cyclically, only at change |
| Settings menu on device | list | Disable |
| Fan control | list | Disable |
| Transmit operation mode and fan step | list | not cyclically, only at change |
| Switching program after reset | list | No program |
| Language after download | list | Türkçe |
| Switchover between heating and cooling | list | Automatically |
| Offset for temperature sensor 0.1K Steps ( -50..50 ) | signedInt -50…50 | 0 |
| Maximum allowed setpoint offset | list | manual adjustment not allowed |
| Value for fan level 1 | unsignedInt 0…200 | 0 |
| Value for fan level 2 | unsignedInt 0…200 | 0 |
| Value for fan level 3 | unsignedInt 0…200 | 0 |
| Switchover fan auto and manual mode | list | Via object "Fan auto/manual", auto is 0 |
| Heating integral reset time | unsignedInt 0…250 | 0 |
| Show extra objects | list | no |
| Ets data loaded | list | yes |
| Heating transmit control value cyclically | list | not cyclically, only at change |
| Select date-time object | list | Time object only |
| Fan level object type | list | 1-Byte object, percentage value 0-100 % |
| Use heating control object | list | No ( 4 pipe system ) |
| ( with 2 step control cooling and heating hystereses is add to value ) | text |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Thermostat STD 1.2 latest | $0203 | 677C | 2026-11-25 | 76 KB | Download |
| Thermostat STD 0.1 | $0203 | A98B | 2026-11-25 | 73 KB | Download |
About this file
This is the official ETS product database for the Panasonic Thermostat STD (WRKT3300XXX/WRKT3400XXX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Panasonic
- Thermostat MD WRKT3310XXX
- KNX POWER SUPPLY UNIT 320 mA WRKT20145NC
- KNX POWER SUPPLY UNIT 640 mA WRKT20275NC
- KNX Power Supply 320mA PS132 WRKT20305NC
- KNX Power Supply 640 mA PS164 WRKT20315NC
- KNX AREA/LINE COUPLER WRKT21015NC
- KNX AREA / LINE COUPLER WRKT21025NC
- KNX SECURE AREA/LINE COUPLER WZ WRKT21035NC
- KNX DALI GATEWAY GV 1/2 Channel WRKT22145/22155NC
- KNX IP INTERFACE WRKT23305NC
- KNX IP ROUTER WRKT23315NC
- KNX SECURE IP INTERFACE WZ WRKT23505NC