KNX Database

Presence detector P34MR, KNX, 360°, for flush mounting and flush-mounting box 350-34002

NIKO · Order number 350-34002 · KNX › Indoor

Download .knxprod KNX01-NK 0.2 · 165 KB

Product

ManufacturerNIKO
Product namePresence detector P34MR, KNX, 360°, for flush mounting and flush-mounting box
Order number350-34002
Hardware409-KNX
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2021-07-02
Languagesen-US, de-DE, fr-FR, it-IT, nl-NL, pl-PL, sk-SK
Catalog entryM-01FC_H-NK001-1_HP-0001-02-905E_CI-350.2D34002-1
Fingerprint905E
SHA-2567566175d4b6a1f9b2d26d49394386e634576d3af369d3c7278382667b34bcb9a
First seen2026-11-25
Markets18 markets

Application program: KNX01-NK 0.2

Application number$0001
Version0.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters243
Group objects78
Group objects (78)
NoNameFunctionSizeDPTFlags
1Secondary outputSecondary motion 1 Bit1.1 switchCRT
2Measured lux levelLux level2 Bytes9.4 lux (Lux)CRT
3External lux levelLux level2 Bytes9.4 lux (Lux)CW
4External LED commandOn/Off1 Bit1.1 switchCW
5Night ModeOn/Off1 Bit1.1 switchCW
6Channel 1 On/OffOn/Off 1 Bit1.1 switchCRT
7Channel 1 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
8Channel 1 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
9Channel 1 Secondary inputSecondary motion1 Bit1.1 switchCW
10Channel 1 Lux levelLux value2 Bytes9.4 lux (Lux)CW
11Channel 1 Switch-off delay timeSwitch-off delay time2 Bytes7.5 time (s)CW
12Channel 1 External On/OffOn/Off1 Bit1.1 switchCW
13Channel 1 External dimming relativeDimming relative4 Bit3.7 dimming controlCW
14Channel 1 External dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CW
15Channel 1 Lux level switchOn/Off1 Bit1.1 switchCRT
16Channel 1 Lock modeOn/Off1 Bit1.1 switchCW
17Channel 1 Automatic/ManualOn/Off1 Bit1.1 switchCW
18Channel 1 AlarmOn/Off1 Bit1.1 switchCRT
19Channel 2 On/OffOn/Off1 Bit1.1 switchCRT
20Channel 2 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
21Channel 2 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
22Channel 2 Secondary inputSecondary motion1 Bit1.1 switchCW
23Channel 2 Lux levelLux value2 Bytes9.4 lux (Lux)CW
24Channel 2 Switch-off delay timeSwitch-off delay time2 Bytes7.5 time (s)CW
25Channel 2 External On/OffOn/Off1 Bit1.1 switchCW
26Channel 2 External dimming relativeDimming relative4 Bit3.7 dimming controlCW
27Channel 2 External dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CW
28Channel 2 Lux level switchOn/Off1 Bit1.1 switchCRT
29Channel 2 Lock modeOn/Off1 Bit1.1 switchCW
30Channel 2 Automatic/ManualOn/Off1 Bit1.1 switchCW
31Channel 2 AlarmOn/Off1 Bit1.1 switchCRT
32Channel 3 On/OffOn/Off1 Bit1.1 switchCRT
33Channel 3 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
34Channel 3 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
35Channel 3 Secondary inputSecondary motion1 Bit1.1 switchCW
36Channel 3 Lux levelLux value2 Bytes9.4 lux (Lux)CW
37Channel 3 Switch-off delay timeSwitch-off delay time2 Bytes7.5 time (s)CW
38Channel 3 External On/OffOn/Off1 Bit1.1 switchCW
39Channel 3 External dimming relativeDimming relative4 Bit3.7 dimming controlCW
40Channel 3 External dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CW
41Channel 3 Lux level switchOn/Off1 Bit1.1 switchCRT
42Channel 3 Lock modeOn/Off1 Bit1.1 switchCW
43Channel 3 Automatic/ManualOn/Off1 Bit1.1 switchCW
44Channel 3 AlarmOn/Off1 Bit1.1 switchCRT
45HVAC On/OffOn/Off 1 Bit1.1 switchCRT
46HVAC Secondary inputSecondary motion1 Bit1.1 switchCW
47HVAC Switch-off delay timeTime Value (sec.)2 Bytes7.5 time (s)CW
48HVAC External On/OffOn/Off 1 Bit1.1 switchCW
49HVAC LockOn/Off 1 Bit1.1 switchCW
50HVAC switch-on delay timeTime Value (sec.)2 Bytes7.5 time (s)CW
51Channel 1 Zone 2 OnOffOn/Off 1 Bit1.1 switchCRT
52Channel 1 Zone 2 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
53Channel 1 Zone 2 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
54Channel 1 Zone 3 OnOffOn/Off 1 Bit1.1 switchCRT
55Channel 1 Zone 3 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
56Channel 1 Zone 3 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
57Channel 1 Zone 4 OnOffOn/Off 1 Bit1.1 switchCRT
58Channel 1 Zone 4 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
59Channel 1 Zone 4 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
60Channel 2 Zone 2 OnOffOn/Off 1 Bit1.1 switchCRT
61Channel 2 Zone 2 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
62Channel 2 Zone 2 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
63Channel 2 Zone 3 OnOffOn/Off 1 Bit1.1 switchCRT
64Channel 2 Zone 3 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
65Channel 2 Zone 3 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
66Channel 2 Zone 4 OnOffOn/Off 1 Bit1.1 switchCRT
67Channel 2 Zone 4 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
68Channel 2 Zone 4 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
69Channel 3 Zone 2 OnOffOn/Off 1 Bit1.1 switchCRT
70Channel 3 Zone 2 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
71Channel 3 Zone 2 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
72Channel 3 Zone 3 OnOffOn/Off 1 Bit1.1 switchCRT
73Channel 3 Zone 3 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
74Channel 3 Zone 3 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
75Channel 3 Zone 4 OnOffOn/Off 1 Bit1.1 switchCRT
76Channel 3 Zone 4 Dimming relativeDimming relative4 Bit3.7 dimming controlCRT
77Channel 3 Zone 4 Dimming absoluteDimming absolute1 Byte5.1 percentage (0..100%)CRT
78General_Test outputOn/Off1 Bit1.1 switchCRT
Parameters (109)
ParameterTypeDefault
Behaviour when no more motion is detectedlistSwitch OFF
Behaviour when motion is detectedlistSwitch ON
Constant light control delaytime30
Dimming speedunsignedInt 1…2555
Dimming relativelist1.5625%
>Dimming value for “Day” when OFFunsignedInt 0…1000
>Dimming value for “Day” when ONunsignedInt 0…100100
Switch-off time frametime5
Detection time frametime5
HysteresisunsignedInt 1…10010
Switch-off delaytime180
Lock modelistDisable
>Lock object = 0listUnlock and Switch ON
>Lock object = 1listLock and Switch OFF
Lux value switch function for day modelistOFF
Lux value switch function for night modelistOFF
Number of time frames without detected motions to stop the alarmunsignedInt 1…2551
Number of time frames with detected motions to trigger the alarmunsignedInt 1…2553
Brightness above which it is switched onunsignedInt 0…1000
Lux level adjustment (10 - 2000 lux)unsignedInt 10…2000500
Lux level adjustment (for night mode) (10 - 2000 lux)unsignedInt 10…2000300
Repeat last command every… (00:00:00=Disable)time0
Brightness below which it is switched onunsignedInt 0…10090
Switch back to Automatic/Semi-Automatic after motionlistEnable
Objects for manual overridelistDisable
Lux level adjustment (10 - 2000 lux)unsignedInt 10…20001000
>Switch-off warninglistDisable
Switch-on lux adjustment (0=Always ON, 2000 lux max)unsignedInt 0…2000500
Switch-on lux adjustment (for night mode) (0=Always ON, 2000 lux max)unsignedInt 0…20000
Switch-off when below the lux levellistOFF
Output mode-1listSwitch
Additional switch objectlistEnable
>Warning brightness settingunsignedInt 0…10020
>Warning brightness setting (in night mode)unsignedInt 0…10020
>Warning timetime60
>Warning brightness settingunsignedInt 0…10010
>Warning brightness setting (in night mode)unsignedInt 0…10010
HysteresisunsignedInt 0…10010
Brightness below which it is switched onunsignedInt 0…1000
>Warning timetime180
Channel 1listAutomatic
Channel 2listDisable
Channel 3listDisable
Channel 4 (HVAC only)listDisable
>Day/night modelistAlways day
>Day/night mode object valuelistDay =1 , Night =0
delayTime1unsignedInt 0…655350
Use external lux valuelistDisable
Device functionlistMaster
ETS_SetupFlagunsignedInt 0…255255
LED behaviour when no more motion is detectedlistOFF
LED behaviour when motion is detectedlistON
LED behaviour when in lock modelistBlink
>Lux value sending modelistLux report when change
>Send lux value everytime60
Send lux value on KNX buslistDisable
>Send lux value when value varies byunsignedInt 1…10010
Sensitivity adjustmentlistMaximum
>Switch between day and night modelistBy next detected motion
Switch-off lux adjustmentunsignedInt 0…20000
LED behaviour when triggered by an external devicelistOff
Advanced ModelistDisable
Switch-on delaytime0
Night ModelistDisable
Dimming ValueunsignedInt 0…1000
Light zoneslist1
Dimming valueunsignedInt 0…1000
Dimming value for Day when OFFlistDo nothing
Dimming value for Day when ONlistDo nothing
Dimming value for Night when OFFlistDo nothing
Dimming value for Night when ONlistDo nothing
Semi-Automatic modelistDisable
Switch back time for Automatic/Semi-Automatic (00:00:00=Disable)time32400
>Switch back time for Automatic after Lock Mode (00:00:00=Disable)time0
Delay switch-off commandlist100ms
Delay switch-on commandlist100ms
>Offset zone 2list-50%
>Offset zone 3list-50%
>Offset zone 4list-50%
Semi-Automatic modelistAutomatic ON / Manual OFF
>Switch back time for Automatic after Lock Mode (00:00:00=Disable)time64512
Correction factorlistSimple
Lux value at the ceiling sensorunsignedInt 1…2000300
Lux value at the deskunsignedInt 1…2000300
Lux value switch function for night modelistSwitch OFF
>Relation between brightness on table and brightness at sensorlist3
CH tt1unsignedInt 0…2550
CH tt2unsignedInt 0…2550
CH tt3unsignedInt 0…2550
>ValueunsignedInt 0…1000
Output mode-2listDimming relative
CH1 t1unsignedInt 0…2550
CH1 t2unsignedInt 0…2550
CH1 t3unsignedInt 0…2550
CH1 tp1unsignedInt 0…655350
CH1 tp2unsignedInt 0…655350
CH1 tp3unsignedInt 0…655350
CH2 t1unsignedInt 0…2550
CH2 t2unsignedInt 0…2550
CH2 t3unsignedInt 0…2550
CH2 tp1unsignedInt 0…655350
CH2 tp2unsignedInt 0…655350
CH2 tp3unsignedInt 0…655350
CH3 t1unsignedInt 0…2550
CH3 t2unsignedInt 0…2550
CH3 t3unsignedInt 0…2550
CH3 tp1unsignedInt 0…655350
CH3 tp2unsignedInt 0…655350
CH3 tp3unsignedInt 0…655350

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX01-NK 0.2 latest$0001905E2026-11-25165 KBDownload
KNX01-NK 0.1$000186BD2026-11-25139 KBDownload

About this file

This is the official ETS product database for the NIKO Presence detector P34MR, KNX, 360°, for flush mounting and flush-mounting box (350-34002), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.