KNX Database

25240 SG 300-3PIR 25240N

NIKO · Order number 25240N · Presence Detector › Wall

Swiss Garde 300-3PIR CLC

Download .knxprod v2.7 (1xLight On/Off, 2xLight DIM/CLC, HVAC, M/S) 2.7 · 94 KB

Product

ManufacturerNIKO
Product name25240 SG 300-3PIR
Order number25240N
HardwareSG 300 KNX/KLR
MediumTwisted Pair
Bus current (mA)15
Rail mountedNo
RegistrationRegistered · 2022-12-15
Languagesen-US
Catalog entryM-01FC_H-ZU.200003.2F1-1_HP-0014-27-DDCA_CI-25240N-0
FingerprintDDCA
SHA-25621a306992720c6e285435877b7a8dddfaf94cf8c39595bfd83f5027ff15508c0
First seen2026-11-25
Markets18 markets

Application program: v2.7 (1xLight On/Off, 2xLight DIM/CLC, HVAC, M/S) 2.7

Application number$0014
Version2.7
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version3.0d
Parameters193
Group objects30
Group objects (30)
NoNameFunctionSizeDPTFlags
0Output - lightDim completely1 Byte5.1 percentage (0..100%)CRT
0Output - lightSwitch1 Bit1.1 switchCRT
0Output - lightScene1 Byte5.1 percentage (0..100%)CRT
1External switch / status - lightSwitch1 Bit1.1 switchCW
2External motion - lightSwitch1 Bit1.1 switchCW
3Input - lightForced control2 Bit2.1 switch controlCW
3Input - lightDisable1 Bit1.1 switchCW
4Output - HVAC (switching)Switch1 Bit1.1 switchCRT
4Output - HVAC (switching)Dim completely1 Byte5.1 percentage (0..100%)CRT
4Output - HVAC (switching)Scene1 Byte5.1 percentage (0..100%)CRT
5External switch / status - HVAC Switch1 Bit1.1 switchCW
6External motion - HVAC (switching)Switch1 Bit1.1 switchCW
7Input - HVAC Forced control2 Bit2.1 switch controlCW
7Input - HVAC Disable1 Bit1.1 switchCW
8Brightness threshold switch valueSwitch1 Bit1.1 switchCRT
9Brightness value (lux)Brightness value (lux)2 Bytes9.4 lux (Lux)CRT
10AD calibration valueAD calibration value2 Bytes8.1 pulses differenceCRT
11Delay timeTime [s]2 BytesCRWU
12Brightness lower limitLux2 Bytes9.4 lux (Lux)CRWU
13Reserve object1 Bit
14Constant LightDimm forced4 Bit3.7 dimming controlCW
15Reserve object1 Bit
16Constant light controlSwitch On/Off1 Bit1.1 switchCW
17Constant light controlDim relative4 Bit3.7 dimming controlCW
18Constant light controlDim completely1 Byte5.1 percentage (0..100%)CW
20Constant light controlForced control1 Bit1.1 switchCW
21Constant light controlScene1 ByteCW
22Constant light control channel 1Output1 Byte5.1 percentage (0..100%)CT
23Constant light control channel 2Output1 Byte5.1 percentage (0..100%)CRT
24LightStandby1 Bit1.1 switchCWU
Parameters (120)
ParameterTypeDefault
Type of detectorlistMaster
9/23/2015text23.06.2015
Delay time for forced control modelist9 h
EinschaltverzögerungunsignedInt 0…2555
Operating mode of the detectorlistAutomatic (no reaction after restart)
Operating mode of the detectorlistFully automatic
Select CalibrationlistFully automatic
Green LEDlistWhen motion
Delay timelist1 min
Brightness below which sensor is activelistalways
Brightness switch-off levellistOFF
Forced control object or disabled objectlistDisable object
If disabled object = 0listAutomatic
If disabled object = 1listForced control OFF
Object type for output - lightlistSwitching
Object value for ONlist100%
Object value for ONlistON
Object value for ONlistScene 2
ValuelistON
Object value for OFFlist0%
Object value for OFFlistOFF
Object value for OFFlistScene 3
Transmission condition for switching objectlistON and OFF
Transmission condition for external switchlistON and OFF
Idle time after switch offlist1 s
Cyclical transmissionlistOFF
Standby valueslistInactive
Standby time 1list1 h
Standby value 1list80%
Standby time 2list50 min
Standby value 2list75%
LEDlistOFF
Delay timelist5 min
Brightness HLKunsignedInt 0…655350
Number of monitoring time intervalslist1
Length of the monitoring time interval (s)unsignedInt 0…300001
Object type for output - HVAClistSwitching
Transmission of the lux value in case of change oflist100 Lux
Cyclical transmission of the lux valuelistOFF
Brightness value threshold for switchinglist500 Lux
Hysteresislist50 Lux
Transmission filterlistON and OFF
CalibrationlistFactory calibration
Adjustment brightness sensorlistFactory calibration
AD Kalibrierwert 1unsignedInt 0…655350
Luxwert 1unsignedInt 0…655350
AD calibration valueunsignedInt 0…655350
Lux valueunsignedInt 0…655350
Anzahl Messungen für MittelwertbildungunsignedInt 3…3010
Offset Sensor 1unsignedInt 0…655352047
Offset Sensor 2unsignedInt 0…655352047
Offset Sensor 3unsignedInt 0…655352047
Active sensorslist123
Sensitivity settings 1 = min, 10 = maxlist5
triggerLevelCh_1unsignedInt 0…655351000
triggerLevelCh_2unsignedInt 0…655351000
triggerLevelCh_3unsignedInt 0…655351000
M1 pirLevelMultunsignedInt 0…25510
M2 pirExtMultunsignedInt 0…2550
M3 pirDiffMultunsignedInt 0…2550
M3 pirDiffMultunsignedInt 0…2550
L1 pirDetectLevelunsignedInt 0…25510
P1 Offet SensorunsignedInt 0…655352047
P1 trigger levelunsignedInt 0…655351000
P2 pirExtrLevelunsignedInt 0…655350
P3 pirDiffLevelunsignedInt 0…655350
###unsignedInt 0…2550
Constant light controllerlistSwitch-off
Channel 2 for constant light controllistInactive
### Kp - MulltipliersignedInt -32768…3276740
### Kp - DividersignedInt -32768…3276710
### Ki - MulltipliersignedInt -32768…327671
### Ki - DividersignedInt -32768…327672500
### Kd - MultipliersignedInt -32768…327670
### Cycle Time [0,1s]unsignedInt 1…32767500
### Dead BandunsignedInt 1…502
Transmit differencelist10%
###unsignedInt 0…2551
###unsignedInt 0…25522
###unsignedInt 0…25551
Sende Differenzlist1%
###unsignedInt 0…25523
Preset setpointlist300 lx
###list10%
###unsignedInt 0…10
###list1%
Switch constant light control withlistMotion detector light
###listNo cyclical transmission
Time interval for cyclic transmissionlistNo cyclical transmission
Regler schaltet Licht auslistdisabled
Switch on brightness valuelist70%
Time after switch-on until constant light control startslist5 s
Offset channel 2list0% synchronous
Forced control during switch-onlistNo reaction
###unsignedInt 0…11
Forced control during switch-offlistNo reaction
Time for relative dimminglist5 s
Relatives Dimmen Schrittlist1%
Take over setpoint afterlist5 s
Changed setpoint to flash memorylistdisabled
Keep changed setpointlistNo
ScenelistSwitch-off
Scene 1list500 lx
Scene 2list500 lx
Scene 3list500 lx
Scene 4list500 lx
Scene 5list500 lx
Scene 6list500 lx
Scene 7list500 lx
Scene 8list500 lx
PID parameterslistDefault value
###signedInt -32768…327670
Dead zoneunsignedInt 1…502
Cycle timeunsignedInt 1…32767500
Kp - MulltipliersignedInt -32768…3276740
Kp - DividersignedInt -32768…3276710
Ki - MulltipliersignedInt -32768…327671
Ki - DividersignedInt -32768…327672500
Kd - MultipliersignedInt -32768…327670
nicht sichtbarlist0

Version history

ApplicationApp noFingerprintFirst seenSizeFile
v2.7 (1xLight On/Off, 2xLight DIM/CLC, HVAC, M/S) 2.7 latest$0014DDCA2026-11-2594 KBDownload

About this file

This is the official ETS product database for the NIKO 25240 SG 300-3PIR (25240N), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.