MM Electro MM2-PB-xxxx-yyy MM2-PB-xxxx-yyy Switch Sensor / Multi Button

MM2-PB-xxxx-yyy Switch Sensor / Multi Button MM2-PB-xxxx-yyy

MM Electro · Order number MM2-PB-xxxx-yyy · Push Button › Push Button General

Switch Sensor

Download .knxprod Switch Sensor, Temperature, Humidity, Air Quality, Room Temperature Controller, Logic Controller 1.3 · 425 KB

Product

ManufacturerMM Electro
Product nameMM2-PB-xxxx-yyy Switch Sensor / Multi Button
Order numberMM2-PB-xxxx-yyy
HardwareMM2-PB-xxxx-yyy
MediumTwisted Pair
Bus current (mA)20
Rail mountedNo
RegistrationCertified · 2026-02-12
Languagestr-TR, en-US
Catalog entryM-029A_H-100900-49-O0234_HP-CA00-13-C308-O0234_CI-MM2.2DPB.2Dxxxx.2Dyyy-1
FingerprintC308
SHA-2568757e096909e21aa1e3f9e661a5f5a3d99c5f8a91291c3c2d9225a0071d81e7f
First seen2026-11-25
Markets69 markets

Application program: Switch Sensor, Temperature, Humidity, Air Quality, Room Temperature Controller, Logic Controller 1.3

Application number$CA00
Version1.3
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters1469
Group objects385
Group objects (385)
NoNameFunctionSizeDPTFlags
0RTC | MasterSync RTC Configuration to Slave4 Bytes12.1 counter pulses (unsigned)CRT
0RTC | SlaveSync RTC Configuration from Master4 Bytes12.1 counter pulses (unsigned)CW
0Sensor | TemperatureEnable Input1 Bit1.3 enableCW
0Sensor | HumidityEnable Input1 Bit1.3 enableCW
0Sensor | Air QualityEnable Input1 Bit1.3 enableCW
0LA - {{Number}} | Inactivity MonitorStart/Stop Monitoring1 Bit1.10 start/stopCRWT
0LA - {{Number}} | Filter/DelayInput1 Bit1.1 switchCW
0LA - {{Number}} | Filter/DelayInput1 Byte5.10 counter pulses (0..255)CW
0LA - {{Number}} | Filter/DelayInput1 Byte6.10 counter pulses (-128..127)CW
0LA - {{Number}} | Filter/DelayInput1 Byte5.1 percentage (0..100%)CW
0LA - {{Number}} | Filter/DelayInput2 Bytes7.1 pulsesCW
0LA - {{Number}} | Filter/DelayInput2 Bytes8.1 pulses differenceCW
0LA - {{Number}} | Filter/DelayInput2 Bytes9.1 temperature (°C)CW
0LA - {{Number}} | Filter/DelayInput4 Bytes12.1 counter pulses (unsigned)CW
0LA - {{Number}} | Filter/DelayInput4 Bytes13.1 counter pulses (signed)CW
0LA - {{Number}} | Filter/DelayInput4 BytesDPT.14CW
0LA - {{Number}} | PresetCall Preset1 Bit1.22 sceneCW
0LA - {{Number}} | Logic GateInput - 11 Bit1.1 switchCW
0LA - {{Number}} | GateInput1 Bit1.1 switchCW
0LA - {{Number}} | GateInput4 BitDPT.3CW
0LA - {{Number}} | GateInput1 Byte5.10 counter pulses (0..255)CW
0LA - {{Number}} | GateInput1 Byte6.10 counter pulses (-128..127)CW
0LA - {{Number}} | GateInput1 Byte5.1 percentage (0..100%)CW
0LA - {{Number}} | GateInput2 Bytes7.1 pulsesCW
0LA - {{Number}} | GateInput2 Bytes8.1 pulses differenceCW
0LA - {{Number}} | GateInput2 Bytes9.1 temperature (°C)CW
0LA - {{Number}} | ThresholdInput1 Byte5.10 counter pulses (0..255)CW
0LA - {{Number}} | ThresholdInput1 Byte6.10 counter pulses (-128..127)CW
0LA - {{Number}} | ThresholdInput1 Byte5.1 percentage (0..100%)CW
0LA - {{Number}} | ThresholdInput2 Bytes7.1 pulsesCW
0LA - {{Number}} | ThresholdInput2 Bytes8.1 pulses differenceCW
0LA - {{Number}} | ThresholdInput2 Bytes9.1 temperature (°C)CW
0LA - {{Number}} | ThresholdInput4 Bytes12.1 counter pulses (unsigned)CW
0LA - {{Number}} | ThresholdInput4 Bytes13.1 counter pulses (signed)CW
0LA - {{Number}} | ThresholdInput4 BytesDPT.14CW
0LA - {{Number}} | SceneLight Scene Number1 Byte18.1 scene controlCW
0Row - {{Object_Name}}LED Input1 Bit1.2 booleanCW
0Row - {{Object_Name}}LED Input1 Byte5.10 counter pulses (0..255)CW
0DisplayLock Display1 Bit1.9 open/closeCRW
1GeneralDay/Night Mode (Day=0, Night=1)1 Bit1.24 day/nightCW
1GeneralDay/Night Mode (Day=1, Night=0)1 Bit1.24 day/nightCW
1RTC | MasterSync Fan Configuration to Slave1 Byte5.10 counter pulses (0..255)CRWT
1RTC | SlaveSync Fan Configuration from Master1 Byte5.10 counter pulses (0..255)CWT
1Sensor | TemperatureValue Output2 Bytes9.1 temperature (°C)CRT
1Sensor | HumiditySensor Output2 Bytes9.7 humidity (%)CRT
1Sensor | Air QualitySensor Output (VOC Index)2 Bytes7.1 pulsesCRT
1LA - {{Number}} | Inactivity MonitorMovement Input1 Bit1.1 switchCW
1LA - {{Number}} | Filter/DelayOutput1 Bit1.1 switchCT
1LA - {{Number}} | Filter/DelayOutput1 Byte5.10 counter pulses (0..255)CT
1LA - {{Number}} | Filter/DelayOutput1 Byte6.10 counter pulses (-128..127)CT
1LA - {{Number}} | Filter/DelayOutput1 Byte5.1 percentage (0..100%)CT
1LA - {{Number}} | Filter/DelayOutput2 Bytes7.1 pulsesCT
1LA - {{Number}} | Filter/DelayOutput2 Bytes8.1 pulses differenceCT
1LA - {{Number}} | Filter/DelayOutput2 Bytes9.1 temperature (°C)CT
1LA - {{Number}} | Filter/DelayOutput4 Bytes12.1 counter pulses (unsigned)CT
1LA - {{Number}} | Filter/DelayOutput4 Bytes13.1 counter pulses (signed)CT
1LA - {{Number}} | Filter/DelayOutput4 BytesDPT.14CT
1LA - {{Number}} | PresetOutput - 11 Bit1.1 switchCT
1LA - {{Number}} | PresetOutput - 11 Byte5.10 counter pulses (0..255)CT
1LA - {{Number}} | PresetOutput - 12 Bytes7.1 pulsesCT
1LA - {{Number}} | PresetOutput - 12 Bytes8.1 pulses differenceCT
1LA - {{Number}} | PresetOutput - 12 Bytes9.1 temperature (°C)CT
1LA - {{Number}} | Logic GateInput - 21 Bit1.1 switchCW
1LA - {{Number}} | GateControl Input1 Bit1.3 enableCW
1LA - {{Number}} | ThresholdOutput1 Bit1.1 switchCT
1LA - {{Number}} | ThresholdOutput1 Byte5.10 counter pulses (0..255)CT
1LA - {{Number}} | ThresholdOutput1 Byte6.10 counter pulses (-128..127)CT
1LA - {{Number}} | ThresholdOutput1 Byte5.1 percentage (0..100%)CT
1LA - {{Number}} | SceneChannel - 1 Output1 Bit1.1 switchCT
1LA - {{Number}} | SceneChannel - 1 Output1 Bit1.8 up/downCT
1LA - {{Number}} | SceneChannel - 1 Output1 Byte5.10 counter pulses (0..255)CT
1LA - {{Number}} | SceneChannel - 1 Output1 Byte5.1 percentage (0..100%)CT
1LA - {{Number}} | SceneChannel - 1 Output2 Bytes9.1 temperature (°C)CT
1Row - {{Object_Name}}Switch1 Bit1.1 switchCWT
1Row - {{Object_Name}}Move1 Bit1.8 up/downCWT
1Row - {{Object_Name}}Move1 Byte5.10 counter pulses (0..255)CWT
1Row - {{Object_Name}}Value1 Byte5.10 counter pulses (0..255)CT
1Row - {{Object_Name}}Value2 Bytes7.1 pulsesCT
1Row - {{Object_Name}}Value2 Bytes9.1 temperature (°C)CT
1Row - {{Object_Name}}Confirm1 Byte5.10 counter pulses (0..255)CW
1Row - {{Object_Name}}Confirm1 Byte6.10 counter pulses (-128..127)CW
1Row - {{Object_Name}}Scene1 Byte18.1 scene controlCT
1DisplayDisplay Unit 0:Celcius 1:Fahrenheit1 Bit1.1 switchCRWT
2RTC | MasterFan Speed Request1 Byte5.10 counter pulses (0..255)CW
2Sensor | TemperatureTreshold Value2 Bytes9.1 temperature (°C)CRT
2Sensor | TemperatureTreshold Value2 Bytes9.1 temperature (°C)CRWT
2Sensor | HumidityTreshold Status1 Bit1.1 switchCT
2Sensor | HumidityTreshold Status1 Byte5.10 counter pulses (0..255)CT
2Sensor | HumidityTreshold Status1 Byte5.1 percentage (0..100%)CT
2Sensor | HumidityTreshold Status1 Byte17.1 scene numberCT
2Sensor | HumidityTreshold Status1 Byte20.102 HVAC modeCT
2Sensor | HumidityTreshold Status2 Bytes9.1 temperature (°C)CT
2Sensor | Air QualitySensor Output (ppm)2 Bytes9.8 parts/million (ppm)CRT
2LA - {{Number}} | Inactivity MonitorAction at Detection1 Bit1.1 switchCT
2LA - {{Number}} | Inactivity MonitorAction at Detection1 Byte5.10 counter pulses (0..255)CT
2LA - {{Number}} | Inactivity MonitorAction at Detection1 Byte5.1 percentage (0..100%)CT
2LA - {{Number}} | Inactivity MonitorAction at Detection1 Byte17.1 scene numberCT
2LA - {{Number}} | Inactivity MonitorAction at Detection1 Byte20.102 HVAC modeCT
2LA - {{Number}} | Inactivity MonitorAction at Detection2 Bytes9.1 temperature (°C)CT
2LA - {{Number}} | Filter/DelayDelay Time2 Bytes7.4 time (100 ms)CRWT
2LA - {{Number}} | Filter/DelayDelay Time2 Bytes7.5 time (s)CRWT
2LA - {{Number}} | PresetOutput - 21 Bit1.1 switchCT
2LA - {{Number}} | PresetOutput - 21 Byte5.10 counter pulses (0..255)CT
2LA - {{Number}} | PresetOutput - 22 Bytes7.1 pulsesCT
2LA - {{Number}} | PresetOutput - 22 Bytes8.1 pulses differenceCT
2LA - {{Number}} | PresetOutput - 22 Bytes9.1 temperature (°C)CT
2LA - {{Number}} | Logic GateInput - 31 Bit1.1 switchCW
2LA - {{Number}} | GateOutput1 Bit1.1 switchCT
2LA - {{Number}} | GateOutput4 BitDPT.3CT
2LA - {{Number}} | GateOutput1 Byte5.10 counter pulses (0..255)CT
2LA - {{Number}} | GateOutput1 Byte6.10 counter pulses (-128..127)CT
2LA - {{Number}} | GateOutput1 Byte5.1 percentage (0..100%)CT
2LA - {{Number}} | GateOutput2 Bytes7.1 pulsesCT
2LA - {{Number}} | GateOutput2 Bytes8.1 pulses differenceCT
2LA - {{Number}} | GateOutput2 Bytes9.1 temperature (°C)CT
2LA - {{Number}} | SceneChannel - 2 Output1 Bit1.1 switchCT
2LA - {{Number}} | SceneChannel - 2 Output1 Bit1.8 up/downCT
2LA - {{Number}} | SceneChannel - 2 Output1 Byte5.10 counter pulses (0..255)CT
2LA - {{Number}} | SceneChannel - 2 Output1 Byte5.1 percentage (0..100%)CT
2LA - {{Number}} | SceneChannel - 2 Output2 Bytes9.1 temperature (°C)CT
2Row - {{Object_Name}}Long Press1 Bit1.1 switchCWT
2Row - {{Object_Name}}Dimming4 Bit3.7 dimming controlCT
2Row - {{Object_Name}}Stop/Step1 Bit1.7 stepCT
2Row - {{Object_Name}}Value1 Byte5.10 counter pulses (0..255)CT
2Row - {{Object_Name}}Value1 Byte6.10 counter pulses (-128..127)CT
2DisplayError1 Bit1.5 alarmCW
3RTC | MasterConfirmed Fan Speed Status1 Byte5.10 counter pulses (0..255)CRT
3Sensor | TemperatureTreshold Status1 Bit1.1 switchCT
3Sensor | TemperatureTreshold Status1 Byte5.10 counter pulses (0..255)CT
3Sensor | TemperatureTreshold Status1 Byte5.1 percentage (0..100%)CT
3Sensor | TemperatureTreshold Status1 Byte17.1 scene numberCT
3Sensor | TemperatureTreshold Status1 Byte20.102 HVAC modeCT
3Sensor | TemperatureTreshold Status2 Bytes9.1 temperature (°C)CT
3Sensor | Air QualityTreshold Status1 Bit1.1 switchCT
3Sensor | Air QualityTreshold Status1 Byte5.10 counter pulses (0..255)CT
3Sensor | Air QualityTreshold Status1 Byte5.1 percentage (0..100%)CT
3Sensor | Air QualityTreshold Status1 Byte17.1 scene numberCT
3Sensor | Air QualityTreshold Status1 Byte20.102 HVAC modeCT
3Sensor | Air QualityTreshold Status2 Bytes9.1 temperature (°C)CT
3LA - {{Number}} | Inactivity MonitorAction End of Monitoring Time1 Bit1.1 switchCT
3LA - {{Number}} | Inactivity MonitorAction End of Monitoring Time1 Byte5.10 counter pulses (0..255)CT
3LA - {{Number}} | Inactivity MonitorAction End of Monitoring Time1 Byte5.1 percentage (0..100%)CT
3LA - {{Number}} | Inactivity MonitorAction End of Monitoring Time1 Byte17.1 scene numberCT
3LA - {{Number}} | Inactivity MonitorAction End of Monitoring Time1 Byte20.102 HVAC modeCT
3LA - {{Number}} | Inactivity MonitorAction End of Monitoring Time2 Bytes9.1 temperature (°C)CT
3LA - {{Number}} | PresetOutput - 31 Bit1.1 switchCT
3LA - {{Number}} | PresetOutput - 31 Byte5.10 counter pulses (0..255)CT
3LA - {{Number}} | PresetOutput - 32 Bytes7.1 pulsesCT
3LA - {{Number}} | PresetOutput - 32 Bytes8.1 pulses differenceCT
3LA - {{Number}} | PresetOutput - 32 Bytes9.1 temperature (°C)CT
3LA - {{Number}} | Logic GateInput - 41 Bit1.1 switchCW
3LA - {{Number}} | SceneChannel - 3 Output1 Bit1.1 switchCT
3LA - {{Number}} | SceneChannel - 3 Output1 Bit1.8 up/downCT
3LA - {{Number}} | SceneChannel - 3 Output1 Byte5.10 counter pulses (0..255)CT
3LA - {{Number}} | SceneChannel - 3 Output1 Byte5.1 percentage (0..100%)CT
3LA - {{Number}} | SceneChannel - 3 Output2 Bytes9.1 temperature (°C)CT
3DisplayError Code2 Bytes7.1 pulsesCW
4RTC | MasterRequest HVAC Control Mode AC Master1 Byte20.105 HVAC control modeCW
4LA - {{Number}} | PresetOutput - 41 Bit1.1 switchCT
4LA - {{Number}} | PresetOutput - 41 Byte5.10 counter pulses (0..255)CT
4LA - {{Number}} | PresetOutput - 42 Bytes7.1 pulsesCT
4LA - {{Number}} | PresetOutput - 42 Bytes8.1 pulses differenceCT
4LA - {{Number}} | PresetOutput - 42 Bytes9.1 temperature (°C)CT
4LA - {{Number}} | Logic GateInput - 51 Bit1.1 switchCW
4LA - {{Number}} | SceneChannel - 4 Output1 Bit1.1 switchCT
4LA - {{Number}} | SceneChannel - 4 Output1 Bit1.8 up/downCT
4LA - {{Number}} | SceneChannel - 4 Output1 Byte5.10 counter pulses (0..255)CT
4LA - {{Number}} | SceneChannel - 4 Output1 Byte5.1 percentage (0..100%)CT
4LA - {{Number}} | SceneChannel - 4 Output2 Bytes9.1 temperature (°C)CT
4DisplayFilter Alarm1 Bit1.5 alarmCW
5RTC | MasterConfirm HVAC Control Mode AC Master1 Byte20.105 HVAC control modeCRT
5LA - {{Number}} | Logic GateInput - 61 Bit1.1 switchCW
5LA - {{Number}} | SceneChannel - 5 Output1 Bit1.1 switchCT
5LA - {{Number}} | SceneChannel - 5 Output1 Bit1.8 up/downCT
5LA - {{Number}} | SceneChannel - 5 Output1 Byte5.10 counter pulses (0..255)CT
5LA - {{Number}} | SceneChannel - 5 Output1 Byte5.1 percentage (0..100%)CT
5LA - {{Number}} | SceneChannel - 5 Output2 Bytes9.1 temperature (°C)CT
5DisplayFilter Reset=11 Bit1.5 alarmCWT
6RTC | MasterRequest Fan Auto1 Bit1.1 switchCW
6LA - {{Number}} | Logic GateInput - 71 Bit1.1 switchCW
6LA - {{Number}} | SceneChannel - 6 Output1 Bit1.1 switchCT
6LA - {{Number}} | SceneChannel - 6 Output1 Bit1.8 up/downCT
6LA - {{Number}} | SceneChannel - 6 Output1 Byte5.10 counter pulses (0..255)CT
6LA - {{Number}} | SceneChannel - 6 Output1 Byte5.1 percentage (0..100%)CT
6LA - {{Number}} | SceneChannel - 6 Output2 Bytes9.1 temperature (°C)CT
6DisplayDrain Full Alarm1 Bit1.5 alarmCW
7RTC | MasterConfirmed Fan Auto1 Bit1.1 switchCRT
7LA - {{Number}} | Logic GateInput - 81 Bit1.1 switchCW
7LA - {{Number}} | SceneChannel - 7 Output1 Bit1.1 switchCT
7LA - {{Number}} | SceneChannel - 7 Output1 Bit1.8 up/downCT
7LA - {{Number}} | SceneChannel - 7 Output1 Byte5.10 counter pulses (0..255)CT
7LA - {{Number}} | SceneChannel - 7 Output1 Byte5.1 percentage (0..100%)CT
7LA - {{Number}} | SceneChannel - 7 Output2 Bytes9.1 temperature (°C)CT
7DisplayDisplay Toggle Button Status1 Bit1.9 open/closeCW
8LA - {{Number}} | Logic GateOutput1 Bit1.1 switchCT
8LA - {{Number}} | Logic GateOutput1 Byte5.10 counter pulses (0..255)CT
8LA - {{Number}} | SceneChannel - 8 Output1 Bit1.1 switchCT
8LA - {{Number}} | SceneChannel - 8 Output1 Bit1.8 up/downCT
8LA - {{Number}} | SceneChannel - 8 Output1 Byte5.10 counter pulses (0..255)CT
8LA - {{Number}} | SceneChannel - 8 Output1 Byte5.1 percentage (0..100%)CT
8LA - {{Number}} | SceneChannel - 8 Output2 Bytes9.1 temperature (°C)CT
8DisplayDisplay Toggle Button1 Bit1.9 open/closeCT
9LA - {{Number}} | SceneChannel - 1 Status1 Bit1.1 switchCWU
9LA - {{Number}} | SceneChannel - 1 Status1 Bit1.8 up/downCWU
9LA - {{Number}} | SceneChannel - 1 Status1 Byte5.10 counter pulses (0..255)CWU
9LA - {{Number}} | SceneChannel - 1 Status1 Byte5.1 percentage (0..100%)CWU
9LA - {{Number}} | SceneChannel - 1 Status2 Bytes9.1 temperature (°C)CWU
10Row - 1Enable Input1 Bit1.3 enableCW
10Row - 1 - LeftEnable Input1 Bit1.3 enableCW
10Row - 1 - Left UpEnable Input1 Bit1.3 enableCW
10Row - 1 / 2Enable Input1 Bit1.3 enableCW
10Row - 1 / 2 - LeftEnable Input1 Bit1.3 enableCW
10RTC | GeneralHVAC Operating Mode1 Byte20.102 HVAC modeCRWT
10RTC | SlaveHVAC Operating Mode1 Byte20.102 HVAC modeCT
10LA - {{Number}} | SceneChannel - 2 Status1 Bit1.1 switchCWU
10LA - {{Number}} | SceneChannel - 2 Status1 Bit1.8 up/downCWU
10LA - {{Number}} | SceneChannel - 2 Status1 Byte5.10 counter pulses (0..255)CWU
10LA - {{Number}} | SceneChannel - 2 Status1 Byte5.1 percentage (0..100%)CWU
10LA - {{Number}} | SceneChannel - 2 Status2 Bytes9.1 temperature (°C)CWU
10DisplayRoom Temperature2 Bytes9.1 temperature (°C)CW
11RTC | GeneralComfort Operating Mode Select1 Bit1.1 switchCRWT
11RTC | SlaveHVAC Operating Mode Status1 Byte20.102 HVAC modeCW
11LA - {{Number}} | SceneChannel - 3 Status1 Bit1.1 switchCWU
11LA - {{Number}} | SceneChannel - 3 Status1 Bit1.8 up/downCWU
11LA - {{Number}} | SceneChannel - 3 Status1 Byte5.10 counter pulses (0..255)CWU
11LA - {{Number}} | SceneChannel - 3 Status1 Byte5.1 percentage (0..100%)CWU
11LA - {{Number}} | SceneChannel - 3 Status2 Bytes9.1 temperature (°C)CWU
11DisplaySet Temperature2 Bytes9.1 temperature (°C)CW
12RTC | GeneralStandby Operation Mode Select1 Bit1.1 switchCRWT
12LA - {{Number}} | SceneChannel - 4 Status1 Bit1.1 switchCWU
12LA - {{Number}} | SceneChannel - 4 Status1 Bit1.8 up/downCWU
12LA - {{Number}} | SceneChannel - 4 Status1 Byte5.10 counter pulses (0..255)CWU
12LA - {{Number}} | SceneChannel - 4 Status1 Byte5.1 percentage (0..100%)CWU
12LA - {{Number}} | SceneChannel - 4 Status2 Bytes9.1 temperature (°C)CWU
12DisplayOutside Temperature2 Bytes9.1 temperature (°C)CW
13RTC | GeneralECO Operating Mode Select1 Bit1.1 switchCRWT
13LA - {{Number}} | SceneChannel - 5 Status1 Bit1.1 switchCWU
13LA - {{Number}} | SceneChannel - 5 Status1 Bit1.8 up/downCWU
13LA - {{Number}} | SceneChannel - 5 Status1 Byte5.10 counter pulses (0..255)CWU
13LA - {{Number}} | SceneChannel - 5 Status1 Byte5.1 percentage (0..100%)CWU
13LA - {{Number}} | SceneChannel - 5 Status2 Bytes9.1 temperature (°C)CWU
13DisplayInside Humidity2 Bytes9.7 humidity (%)CW
14RTC | GeneralProtection Operating Mode Select1 Bit1.1 switchCRWT
14LA - {{Number}} | SceneChannel - 6 Status1 Bit1.1 switchCWU
14LA - {{Number}} | SceneChannel - 6 Status1 Bit1.8 up/downCWU
14LA - {{Number}} | SceneChannel - 6 Status1 Byte5.10 counter pulses (0..255)CWU
14LA - {{Number}} | SceneChannel - 6 Status1 Byte5.1 percentage (0..100%)CWU
14LA - {{Number}} | SceneChannel - 6 Status2 Bytes9.1 temperature (°C)CWU
14DisplayOutside Humidity2 Bytes9.7 humidity (%)CW
15Row - 1 - Left DownEnable Input1 Bit1.3 enableCW
15RTC | GeneralForced Operating Mode1 Byte20.102 HVAC modeCW
15RTC | SlaveForced Operating Mode1 Byte20.102 HVAC modeCW
15LA - {{Number}} | SceneChannel - 7 Status1 Bit1.1 switchCWU
15LA - {{Number}} | SceneChannel - 7 Status1 Bit1.8 up/downCWU
15LA - {{Number}} | SceneChannel - 7 Status1 Byte5.10 counter pulses (0..255)CWU
15LA - {{Number}} | SceneChannel - 7 Status1 Byte5.1 percentage (0..100%)CWU
15LA - {{Number}} | SceneChannel - 7 Status2 Bytes9.1 temperature (°C)CWU
15DisplayInside Air Quality2 Bytes9.8 parts/million (ppm)CW
16RTC | GeneralPresence Detector Input1 Bit1.1 switchCW
16RTC | SlavePresence Detector Input1 Bit1.1 switchCW
16LA - {{Number}} | SceneChannel - 8 Status1 Bit1.1 switchCWU
16LA - {{Number}} | SceneChannel - 8 Status1 Bit1.8 up/downCWU
16LA - {{Number}} | SceneChannel - 8 Status1 Byte5.10 counter pulses (0..255)CWU
16LA - {{Number}} | SceneChannel - 8 Status1 Byte5.1 percentage (0..100%)CWU
16LA - {{Number}} | SceneChannel - 8 Status2 Bytes9.1 temperature (°C)CWU
16DisplayOutside Air Quality2 Bytes9.8 parts/million (ppm)CW
17RTC | GeneralWindows Contact Input1 Bit1.1 switchCW
17RTC | SlaveWindows Contact Input1 Bit1.1 switchCW
18RTC | GeneralRTC Controller RHCC Status2 Bytes22.101 RHCC statusCRT
19RTC | GeneralController HVAC Status1 Byte20.102 HVAC modeCRT
20Row - 1 - RightEnable Input1 Bit1.3 enableCW
20Row - 1 - Right UpEnable Input1 Bit1.3 enableCW
20Row - 1 / 2 - RightEnable Input1 Bit1.3 enableCW
20RTC | SetpointSet Temperature Output2 Bytes9.1 temperature (°C)CRT
20RTC | SlaveRequest Set Temperature2 Bytes9.1 temperature (°C)CW
21RTC | SetpointSet Temperature Request2 Bytes9.1 temperature (°C)CW
21RTC | SlaveSet Temperature Confirm2 Bytes9.1 temperature (°C)CT
22RTC | Temperature ReadingInternal Temperature2 Bytes9.1 temperature (°C)CRT
23RTC | Temperature ReadingActual Temperature Error1 Bit1.5 alarmCT
24RTC | Temperature ReadingExternal Temperature2 Bytes9.1 temperature (°C)CW
25Row - 1 - Right DownEnable Input1 Bit1.3 enableCW
25RTC | Temperature ReadingTemperature Output2 Bytes9.1 temperature (°C)CRT
26RTC | Temperature ReadingFault Temperature Reading1 Bit1.5 alarmCRT
27RTC | Temperature ReadingInstantaneous Temperature Change1 Bit1.5 alarmCRT
28RTC | Heating/CoolingHVAC Control Mode Input1 Byte20.105 HVAC control modeCW
29RTC | Heating/CoolingHVAC Control Mode Status1 Byte20.105 HVAC control modeCRT
30Row - 2Enable Input1 Bit1.3 enableCW
30Row - 2 - LeftEnable Input1 Bit1.3 enableCW
30Row - 2 - Left UpEnable Input1 Bit1.3 enableCW
30Row - 2 / 3Enable Input1 Bit1.3 enableCW
30Row - 2 / 3 - LeftEnable Input1 Bit1.3 enableCW
30RTC | Heating/CoolingHVAC Changeover Mode Select 1 Byte20.107 changeover modeCW
30RTC | SlaveHVAC Changeover Mode Select 1 Byte20.107 changeover modeCW
30RTC | SlaveHVAC Control Mode Select1 Byte20.105 HVAC control modeCW
31RTC | Heating/CoolingHVAC Changeover Mode Status 1 Byte20.107 changeover modeCRT
31RTC | SlaveHVAC Changeover Mode Status 1 Byte20.107 changeover modeCT
31RTC | SlaveHVAC Control Mode Status1 Byte20.105 HVAC control modeCT
32RTC | Heating/CoolingHeating/Cooling Select1 Bit1.100 cooling/heatingCW
32RTC | SlaveHeating/Cooling Select1 Bit1.100 cooling/heatingCW
33RTC | Heating/CoolingHeating/Cooling Control Value1 Bit1.1 switchCT
33RTC | Heating/CoolingHeating/Cooling Control Value1 Byte5.1 percentage (0..100%)CT
34RTC | HeatingHeating Control Value1 Bit1.1 switchCT
34RTC | HeatingHeating Control Value1 Byte5.1 percentage (0..100%)CT
35Row - 2 - Left DownEnable Input1 Bit1.3 enableCW
35RTC | HeatingAdditional Heating Stage1 Bit1.1 switchCT
35RTC | HeatingAdditional Heating Stage1 Byte5.1 percentage (0..100%)CT
36RTC | CoolingCooling Control Value1 Bit1.1 switchCT
36RTC | CoolingCooling Control Value1 Byte5.1 percentage (0..100%)CT
37RTC | CoolingAdditional Cooling Stage1 Bit1.1 switchCT
37RTC | CoolingAdditional Cooling Stage1 Byte5.1 percentage (0..100%)CT
38RTC | Heating/CoolingHeating/Cooling Select Status1 Bit1.100 cooling/heatingCRT
38RTC | SlaveHeating/Cooling Select Status1 Bit1.100 cooling/heatingCT
39RTC | HeatingHeating Status1 Bit1.2 booleanCT
40Row - 2 - RightEnable Input1 Bit1.3 enableCW
40Row - 2 - Right UpEnable Input1 Bit1.3 enableCW
40Row - 2 / 3 - RightEnable Input1 Bit1.3 enableCW
40RTC | CoolingCooling Status1 Bit1.2 booleanCT
41RTC | Air ConditionClimate On/Off1 Bit1.1 switchCT
43RTC | Air ConditionClimate Setpoint2 Bytes9.1 temperature (°C)CT
44RTC | Air ConditionClimate Setpoint Status2 Bytes9.1 temperature (°C)CW
45Row - 2 - Right DownEnable Input1 Bit1.3 enableCW
46RTC | Air ConditionClimate Heat/Cool Select1 Bit1.1 switchCT
47RTC | Air ConditionClimate Heat/Cool Status1 Bit1.1 switchCW
48RTC | Air ConditionHVAC Control Mode Output1 Byte20.105 HVAC control modeCT
49RTC | Air ConditionHVAC Control Mode Status1 Byte20.105 HVAC control modeCW
50Row - 3Enable Input1 Bit1.3 enableCW
50Row - 3 - LeftEnable Input1 Bit1.3 enableCW
50Row - 3 - Left UpEnable Input1 Bit1.3 enableCW
50Row - 3 / 4Enable Input1 Bit1.3 enableCW
50Row - 3 / 4 - LeftEnable Input1 Bit1.3 enableCW
50RTC | Air ConditionHVAC Control Mode Auto1 Bit1.1 switchCT
51RTC | Air ConditionHVAC Control Mode Heat1 Bit1.1 switchCT
52RTC | Air ConditionHVAC Control Mode Cool1 Bit1.1 switchCT
53RTC | Air ConditionHVAC Control Mode Fan1 Bit1.1 switchCT
54RTC | Air ConditionHVAC Control Mode Dry1 Bit1.1 switchCT
55Row - 3 - Left DownEnable Input1 Bit1.3 enableCW
55RTC | Air ConditionFan Speed Value1 Byte5.1 percentage (0..100%)CT
56RTC | Air ConditionFan Speed Step Control1 Bit1.1 switchCW
57RTC | Air ConditionFan Speed Auto1 Bit1.1 switchCT
58RTC | Air ConditionFan Speed 11 Bit1.1 switchCT
59RTC | Air ConditionFan Speed 21 Bit1.1 switchCT
60Row - 3 - RightEnable Input1 Bit1.3 enableCW
60Row - 3 - Right UpEnable Input1 Bit1.3 enableCW
60Row - 3 / 4 - RightEnable Input1 Bit1.3 enableCW
60RTC | Air ConditionFan Speed 31 Bit1.1 switchCT
61RTC | Air ConditionFan Speed 41 Bit1.1 switchCT
62RTC | Air ConditionFan Speed 51 Bit1.1 switchCT
63RTC | Air ConditionFan Speed Status1 Byte5.1 percentage (0..100%)CW
64RTC | Air ConditionFan Speed Auto Status1 Bit1.1 switchCW
65Row - 3 - Right DownEnable Input1 Bit1.3 enableCW
65RTC | Air ConditionFan Speed 1 Status1 Bit1.1 switchCW
66RTC | Air ConditionFan Speed 2 Status1 Bit1.1 switchCW
67RTC | Air ConditionFan Speed 3 Status1 Bit1.1 switchCW
68RTC | Air ConditionFan Speed 4 Status1 Bit1.1 switchCW
69RTC | Air ConditionFan Speed 5 Status1 Bit1.1 switchCW
70Row - 4Enable Input1 Bit1.3 enableCW
70Row - 4 - LeftEnable Input1 Bit1.3 enableCW
70Row - 4 - Left UpEnable Input1 Bit1.3 enableCW
70RTC | Fan CoilFan Speed Auto Control1 Bit1.1 switchCW
70RTC | SlaveFan Speed Auto Control1 Bit1.1 switchCT
71RTC | Fan CoilFan Speed Manual Control1 Bit1.1 switchCW
71RTC | SlaveFan Speed Manual Control1 Bit1.1 switchCT
72RTC | Fan CoilFan Auto / Manual Status1 Bit1.1 switchCRT
72RTC | SlaveFan Auto / Manual Status1 Bit1.1 switchCW
73RTC | Fan CoilFan Speed Set1 Byte5.1 percentage (0..100%)CT
73RTC | SlaveRequest Fan Speed Set1 Byte5.1 percentage (0..100%)CT
73RTC | Fan CoilFan Speed Set1 Byte5.100 fan stage (0..255)CT
74RTC | Fan CoilFan Speed 11 Bit1.1 switchCT
74RTC | SlaveConfirmed Fan Speed Set1 Byte5.1 percentage (0..100%)CW
75Row - 4 - Left DownEnable Input1 Bit1.3 enableCW
75RTC | Fan CoilFan Speed 21 Bit1.1 switchCT
76RTC | Fan CoilFan Speed 31 Bit1.1 switchCT
77RTC | Fan CoilFan Speed 41 Bit1.1 switchCT
78RTC | Fan CoilFan Speed 51 Bit1.1 switchCT
79RTC | Fan CoilFan Speed Step Control1 Bit1.1 switchCW
80Row - 4 - RightEnable Input1 Bit1.3 enableCW
80Row - 4 - Right UpEnable Input1 Bit1.3 enableCW
80RTC | Fan CoilFan Speed Status1 Byte5.1 percentage (0..100%)CW
80RTC | Fan CoilFan Speed Status1 Byte5.100 fan stage (0..255)CW
82RTC | Air ConditionHVAC Control Mode Auto Status1 Bit1.1 switchCW
83RTC | Air ConditionHVAC Control Mode Heat Status1 Bit1.1 switchCW
84RTC | Air ConditionHVAC Control Mode Cool Status1 Bit1.1 switchCW
85Row - 4 - Right DownEnable Input1 Bit1.3 enableCW
85RTC | Air ConditionHVAC Control Mode Fan Status1 Bit1.1 switchCW
86RTC | Air ConditionHVAC Control Mode Dry Status1 Bit1.1 switchCW
Parameters (478)
ParameterTypeDefault
DesignlistStandard
ModellistPB-3300 1-Button
FunctionlistSwitching
Row_1_Left_Up_IDunsignedInt 0…2550
Row_1_Left_Down_IDunsignedInt 0…2550
Row_1_Right_Up_IDunsignedInt 0…2550
Row_1_Right_Down_IDunsignedInt 0…2550
Initial PositionlistEnable
Enable withlistON Telegram
Left ButtonlistSingle Function
Right ButtonlistSingle Function
ButtonlistSingle Function
LadyBug_Fold_CountunsignedInt 0…2550
Row_1_Mode_LeftlistWhole Rocker
Display_EnablelistDisable
Baselist80x80
Row_1_TypelistBig Square
Row_2_TypelistBig Square
Row_3_TypelistBig Square
Row_4_TypelistRectangular
BigButtonpicture
RectangularButtonpicture
SquareButtonpicture
Row_2_TypelistRectangular
Row_3_TypelistRectangular
denemeunsignedInt 0…100
Displaypicture
Row - 1textRow - 1
Row - 2textRow - 2
Row - 3textRow - 3
Row - 4textRow - 4
Row - 1 & 2textRow - 1 / 2
Row - 2 & 3textRow - 2 / 3
Row - 3 & 4textRow - 3 / 4
Digit-1text0
Digit-2text0
Digit-3text0
Digit-4text0
Model NametextPB-0000
Model NametextModel Name
Day/Night ModeunsignedInt 0…10
Day/Night Mode SelectionlistDay=0 Night=1
Enable ObjectunsignedInt 0…10
Activate Button SoundunsignedInt 0…10
Control RTC with Row - 2unsignedInt 0…10
Room Temperature ControllerunsignedInt 0…10
Room Temperature Controller ModelistMaster
Working ModelistNone
Enable Fan Control when in Heating ModeunsignedInt 0…10
Enable Fan Control when in Cooling ModeunsignedInt 0…10
Max Fan Speedlist2
Control FunctionlistHeating
StandbyunsignedInt 0…10
ECOunsignedInt 0…10
Operating Mode After ResetlistPrevious
Temperature SourcelistInternal Sensor
External Temperature Reading OffsetsignedInt -128…1270
Monitoring Time (0=No Monitoring)time0
Weight (Internal/External)unsignedInt 0…1000
PeriodicallyunsignedInt 0…11
Cycle Timetime15
On ChangeunsignedInt 0…11
Change RatiounsignedInt 1…502
Instantaneous Temperature ChangelistNo
Monitoring Timetime1
Temperature DifferenceunsignedInt 1…151
Control Value Typelist2-Point 1-Bit ON/OFF
Status Heating ObjectlistNo
Control DirectionlistNormal
HysteresisunsignedInt 3…25510
Cyclic Sending of Control Valuetime1
Heating TypelistArea 4°C 200min
P ValueunsignedInt 10…10015
I Valuetime100
PWM Cycletime15
Min Control ValueunsignedInt 0…2550
Max Control ValueunsignedInt 1…255255
Change Amountlist2%
Cyclic Sendingtime1
Auto OnunsignedInt 0…10
Auto OffunsignedInt 0…10
Status Cooling ObjectlistNo
Cyclic Sending of Control Valtime1
Cooling TypelistArea 4°C 200min
Switchover Heating/CoolinglistLocal Only
Control Function After ResetlistPrevious
Control Value(s)list1-Common Object
Setpoint TemperatureunsignedInt 10…4024
Deadzonelist1
Standby ReducingunsignedInt 0…202
Economy ReducingunsignedInt 0…204
Frost Protection TempunsignedInt 5…157
Standby IncreasingunsignedInt 0…202
Economy IncreasingunsignedInt 0…204
Heat Protection TempunsignedInt 30…4532
Maximum range at heatingunsignedInt 0…105
Maximum range at coolingunsignedInt 0…105
Remember manual adjustmentunsignedInt 0…10
Reset manual change when change the operating modeunsignedInt 0…10
Default Setpoint TemperatureunsignedInt 16…3024
Send SetpointlistWhile Change
Cyclic Send Setpointtime1
HVAC Control Mode SelectionlistDPT 20.105
Autolist-
Send ValueunsignedInt 0…2550
Coollist1-Bit
Heatlist1-Bit
Fanlist-
Drylist-
Fan Speed Step Control Obj.unsignedInt 0…10
Lowlist1-Byte
Send ValueunsignedInt 0…25585
Low - Mediumlist-
Mediumlist1-Byte
Send ValueunsignedInt 0…255170
Medium - Highlist-
Highlist1-Byte
Send ValueunsignedInt 0…255255
Auto Statuslist-
Active Meanlist1
Active MeanunsignedInt 0…2550
Fan Speed 1 Statuslist-
Fan Speed 2 Statuslist-
Fan Speed 3 Statuslist-
Fan Speed 4 Statuslist-
Fan Speed 5 Statuslist-
Send Value for Fan Auto/Manuallist1:Auto 0:Manual
Number of Fan Levelslist2
Output Format of Levellist0...5 (DPT:5.100)
1-Bit Fan OutputslistDisable
Send Outputs at also Automatic ModeunsignedInt 0…10
Minimum Fan Speed LevellistOFF
Receive Fan Speed StatusunsignedInt 0…10
Fan Speed 1 Start AtunsignedInt 1…25525
Fan Speed 2 Start AtunsignedInt 1…25577
Fan Speed 3 Start AtunsignedInt 1…255128
Fan Speed 4 Start AtunsignedInt 1…255180
Fan Speed 5 Start AtunsignedInt 1…255225
Fan Stage Limit at ECO/Night ModelistNone
Fan Speed Step Control ObjectunsignedInt 0…10
Air Condition EnablelistOFF Telegram
Fan Coil EnablelistOFF Telegram
Internal Temperature Reading OffsetsignedInt -128…1270
Additional Control Typelist2-Point 1-Bit ON/OFF
Additional Heating StageunsignedInt 0…10
Temperature DifferenceunsignedInt 0…25510
Additional Cooling StageunsignedInt 0…10
Fan Coil HeatinglistOFF Telegram
Fan Coil CoolinglistOFF Telegram
HVAC Simplified ModeunsignedInt 0…11
Same as Fan Speed ControlunsignedInt 0…11
Minimum SetpointunsignedInt 16…2618
Maximum SetpointunsignedInt 20…3028
Send Standby and Eco Setpoint to ACunsignedInt 0…10
Recieve Mod Feedback vialistSame as Mode Selection
Fan Speed 2 Start AtunsignedInt 1…255102
Fan Speed 3 Start AtunsignedInt 1…255180
Fan Speed 2 Start AtunsignedInt 1…255128
Switch to comfort mode when set temperature changedunsignedInt 0…10
Sync with same Model master deviceunsignedInt 0…10
Enable AutounsignedInt 0…10
Temperature DetectionunsignedInt 0…10
Humidity DetectionunsignedInt 0…10
Air Quality DetectionunsignedInt 0…10
OffsetsignedInt -128…1270
PeriodicallyunsignedInt 0…10
Cycle Timetime2
On ChangeunsignedInt 0…10
Change RatiounsignedInt 1…501
Threshold ControlunsignedInt 0…10
Threshold ValuesignedInt -10…500
External Threshold ObjectunsignedInt 0…10
Hysteresislist0.5
Output Data Typelist1-Bit
Above ThresholdlistNo Reaction
Send ValuelistON Telegram
Send ValueunsignedInt 0…100100
Send ValuelistScene 1
Send ValuelistComfort
Send Valuefloat -273…67000023
Below ThresholdlistNo Reaction
Send ValuelistOFF Telegram
Send ValueunsignedInt 0…1000
Send ValuelistScene 2
Send ValuelistStandby
Send Valuefloat -273…67000020
Enable ObjectlistNo
OffsetsignedInt -20…500
Control-Point(s)list1-Point
Threshold-Point 1 ValueunsignedInt 10…9010
Common Hysteresis (±)list0
Send ValuelistAuto
Send Valuefloat -273…6700001
Threshold-Point 2=-Point 1+list10
Between Point 1 and-Point 2listNo Reaction
Above Threshold-Point-2listNo Reaction
Threshold-Point 3=-Point 2+list10
Between Point 2 and-Point 3listNo Reaction
Above Threshold-Point-3listNo Reaction
Change Ratiolist30
Threshold-Point 1 Valuelist150
Threshold-Point 2=-Point 1+list50
Threshold-Point 3=-Point 2+list50
Logic 1listNo Logic
Logic 2listNo Logic
Logic 3listNo Logic
Logic 4listNo Logic
Logic 5listNo Logic
Monitoring Timetime300
Start Delaytime5
Auto RepeatlistNever
Action at DetectionlistNo Reaction
Action End of Monitoring TimelistNo Reaction
Send Valuefloat -273…67000021
Input/Output Data Typelist1-Bit
Delay Time Steplist1-Second Step
Delay Timetime0
Delay Time Write ObjectlistNo
Filter FunctionlistNo Filter
Filter CriterialistEqual
Criteria ValuelistOFF Telegram
Criteria ValueunsignedInt 0…2550
Criteria ValueunsignedInt 0…1000
Criteria ValuesignedInt -128…1270
Criteria Valuefloat -273…327670
Criteria ValuesignedInt -32768…327670
Criteria ValueunsignedInt 0…655350
Criteria Valuefloat -2147483648…21474836470
Criteria ValuesignedInt -2147483648…21474836470
Criteria ValueunsignedInt 0…42949672950
Output Countlist1
Output 1 Data Typelist1-Bit
Output 2 Data Typelist1-Bit
Output 3 Data Typelist1-Bit
Output 4 Data Typelist1-Bit
Output 1listNo Reaction
Output 2listNo Reaction
Output 3listNo Reaction
Output 4listNo Reaction
Send ValueunsignedInt 0…6553565535
Send ValuesignedInt -32768…3276732767
Send Valuefloat -273…327670
Send ValueunsignedInt 0…655350
Send ValuesignedInt -32768…327670
Delay Between TelegramslistNo Delay
Number of Inputlist2
Logic OperatorlistAND
Logic OperatorlistNOT
Logic InputlistNormal
Data Typelist1-Bit
Send Output Valuelistin Every Calculation
Output value when logic is Truelist1
Output value when logic is TrueunsignedInt 0…255255
Output value when logic is Falselist0
Output value when logic is FalseunsignedInt 0…2550
Initial ValuelistValue=0
Control Input BehaviourlistNormal
Initial Value of Control InputlistEnable
Send Last Value When Gate EnabledunsignedInt 0…10
Input Data Typelist1-Byte Unsigned
Threshold Countlist1
Threshold 1unsignedInt 0…2550
Threshold 1signedInt -128…1270
Threshold 1unsignedInt 0…1000
Threshold 1unsignedInt 0…655350
Threshold 1signedInt -32768…327670
Threshold 1float -273…327671
Threshold 1unsignedInt 0…42949672950
Threshold 1signedInt -2147483648…21474836470
Threshold 1float -2147483648…21474836471
Less Than ThresholdunsignedInt 0…10
Send ValuesignedInt -128…1270
Less Than Threshold 1unsignedInt 0…10
Greater Than (or Equal) ThresholdunsignedInt 0…10
Greater Than (or Equal) Threshold 1 and Less Than Threshold 2unsignedInt 0…10
Threshold 2unsignedInt 0…2550
Threshold 2signedInt -128…1270
Threshold 2unsignedInt 0…1000
Threshold 2unsignedInt 0…655350
Threshold 2signedInt -32768…327670
Threshold 2float -273…327671
Threshold 2unsignedInt 0…42949672950
Threshold 2signedInt -2147483648…21474836470
Threshold 2float -2147483648…21474836471
Greater Than (or Equal) Threshold 2unsignedInt 0…10
Greater Than (or Equal) Threshold 2 and Less Than Threshold 3unsignedInt 0…10
Threshold 3unsignedInt 0…2550
Threshold 3signedInt -128…1270
Threshold 3unsignedInt 0…1000
Threshold 3unsignedInt 0…655350
Threshold 3signedInt -32768…327670
Threshold 3float -273…327671
Threshold 3unsignedInt 0…42949672950
Threshold 3signedInt -2147483648…21474836470
Threshold 3float -2147483648…21474836471
Greater Than (or Equal) Threshold 3unsignedInt 0…10
Scene NametextScene
Scene Countlist1
Number of Channellist1
Delay Between Telegramstime1
Channel 1list1-Bit Switch
Channel 2list1-Bit Switch
Channel 3list1-Bit Switch
Channel 4list1-Bit Switch
Channel 5list1-Bit Switch
Channel 6list1-Bit Switch
Channel 7list1-Bit Switch
Channel 8list1-Bit Switch
Scene NumberlistScene 1
Scene can be SavedlistNot Allowed
Channel 1listBypass
Send ValuelistUp
Channel 2listBypass
Channel 3listBypass
Channel 4listBypass
Channel 5listBypass
Channel 6listBypass
Channel 7listBypass
Channel 8listBypass
Scene NumberlistScene 2
Scene NumberlistScene 3
Scene NumberlistScene 4
Scene NumberlistScene 5
Scene NumberlistScene 6
Scene NumberlistScene 7
Scene NumberlistScene 8
Overwrite Parameters at DownloadunsignedInt 0…10
FunctionlistStatic
Object Typelist1-Bit
if TruelistOFF
if FalselistOFF
LED ConditionlistEqual to
ValueunsignedInt 0…2550
Value 2unsignedInt 0…2550
BrightnesslistMedium
Brightness if NightlistNo Reaction
ColourlistOFF
Value 1unsignedInt 0…2550
Long Operation Durationlist250ms
Long Press DetectionlistDisable
PresslistUp: OFF Down:ON
Long PresslistUp: OFF Down:ON
Long Press Communication ObjectunsignedInt 0…10
SwitchlistUp: OFF Down:ON
Dimming ModelistUp: BRIGHTER Down: DARKER
Dimming FunctionlistStart-Stop Dimming
Step Codelist1.56%
Button ModelistShort: Switching Long: Dimming
CyclicallistDisable
Dimming Repetetion Durationlist250ms
Button ModelistUp:MOVE UP Down:MOVE DOWN
Move Down LevelunsignedInt 0…2550
Move Up LevelunsignedInt 0…2550
Function TypelistShort Press:MOVE Long Press:STOP
Data Typelist1-Byte
Up ValueunsignedInt 0…2550
Up ValueunsignedInt 0…655350
Up Valuefloat -273…6700000
Down ValueunsignedInt 0…2550
Down ValueunsignedInt 0…655350
Down Valuefloat -273…6700000
Up Long ValueunsignedInt 0…2550
Up Long ValueunsignedInt 0…655350
Up Long Valuefloat -273…6700000
Down Long ValueunsignedInt 0…2550
Down Long ValueunsignedInt 0…655350
Down Long Valuefloat -273…6700000
Long Operation Durationlist1s
Up PresslistFirst
Up Long PresslistFirst
Down PresslistFirst
Down Long PresslistFirst
CycleunsignedInt 0…10
Remember Last ValueunsignedInt 0…10
Array Sizelist3
Value 1unsignedInt 0…655350
Value 1float -273…6700000
Value 2unsignedInt 0…655350
Value 2float -273…6700000
Value 3unsignedInt 0…2550
Value 3unsignedInt 0…655350
Value 3float -273…6700000
Value 4unsignedInt 0…2550
Value 4unsignedInt 0…655350
Value 4float -273…6700000
Value 5unsignedInt 0…2550
Value 5unsignedInt 0…655350
Value 5float -273…6700000
Value 6unsignedInt 0…2550
Value 6unsignedInt 0…655350
Value 6float -273…6700000
Value 7unsignedInt 0…2550
Value 7unsignedInt 0…655350
Value 7float -273…6700000
Value 8unsignedInt 0…2550
Value 8unsignedInt 0…655350
Value 8float -273…6700000
Repetetion Durationlist250ms
End of ArraylistStop
Data Typelist1-Byte Unsigned
CyclicalunsignedInt 0…10
Repetition Durationlist250ms
Up Short PresslistInitial
Up Long PresslistInitial
Down Short PresslistInitial
Down Long PresslistInitial
Min ValuesignedInt -128…1270
Min ValueunsignedInt 0…2550
Max ValuesignedInt -128…1270
Max ValueunsignedInt 0…2550
Step SizeunsignedInt 1…2551
Initial ValuesignedInt -128…1270
Initial ValueunsignedInt 0…2550
Value Dimmer Depends on Confirm ObjectunsignedInt 0…10
Push Hold Timelist4s
Up Button Scene Numberlist1
Down Button Scene Numberlist1
Scene Record TelegramlistNo
PresslistOFF
Long PresslistOFF
SwitchlistOFF
Dimming ModelistBRIGHTER
Button ModelistMOVE UP
ValueunsignedInt 0…655350
Valuefloat -273…6700000
Long ValueunsignedInt 0…2550
Long ValueunsignedInt 0…655350
Long Valuefloat -273…6700000
PresslistFirst
Long PresslistFirst
Short PresslistInitial
Long PresslistInitial
Scene Numberlist1
Temperature DisplaylistRoom Temperature
IntervalunsignedInt 0…631
Outdoor TemperatureunsignedInt 0…10
Inside HumidityunsignedInt 0…10
Outside HumidityunsignedInt 0…10
Inside Air QualityunsignedInt 0…10
Outside Air QualityunsignedInt 0…10
Error ValueunsignedInt 0…10
Filter AlarmunsignedInt 0…10
Drain Full AlarmunsignedInt 0…10
Brightness Levellist100%
Day/Night Brightness LevellistSame Brightness
Backlight Timeouttime10
Lock DisplayunsignedInt 0…10
Always On DisplayunsignedInt 0…11
Function of Power ButtonlistNo Function
Simple Mode afterlistNever
PresslistLeft: OFF Right:ON
Long PresslistLeft: OFF Right:ON
SwitchlistLeft: OFF Right:ON
Dimming ModelistLeft: BRIGHTER Right:DARKER
Button ModelistLeft:MOVE UP Right:MOVE DOWN
Left ValueunsignedInt 0…2550
Left ValueunsignedInt 0…655350
Left Valuefloat -273…6700000
Right ValueunsignedInt 0…2550
Right ValueunsignedInt 0…655350
Right Valuefloat -273…6700000
Left Long ValueunsignedInt 0…2550
Left Long ValueunsignedInt 0…655350
Left Long Valuefloat -273…6700000
Right Long ValueunsignedInt 0…2550
Right Long ValueunsignedInt 0…655350
Right Long Valuefloat -273…6700000
Left PresslistFirst
Left Long PresslistFirst
Right PresslistFirst
Right Long PresslistFirst
Long Press DetectionunsignedInt 0…10
Left Short PresslistInitial
Left Long PresslistInitial
Right Short PresslistInitial
Right Long PresslistInitial
Left Button Scene Numberlist1
Right Button Scene Numberlist1

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch Sensor, Temperature, Humidity, Air Quality, Room Temperature Controller, Logic Controller 1.3 latest$CA00C3082026-11-25425 KBDownload

About this file

This is the official ETS product database for the MM Electro MM2-PB-xxxx-yyy Switch Sensor / Multi Button (MM2-PB-xxxx-yyy), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from MM Electro

All MM Electro products