MM-20-xx-211 Combo Actuator / Multi-Channel MM-20-xx-211
MM Electro · Order number MM-20-xx-211 · Output › Binary Output
Combo Actuator, Multi Channel, MDRC, 16A
Download .knxprod Switch, Shutter, Valve, Fan Coil, v1.0 2.0 · 142 KB
Product
| Manufacturer | MM Electro |
|---|---|
| Product name | MM-20-xx-211 Combo Actuator / Multi-Channel |
| Order number | MM-20-xx-211 |
| Hardware | Combo Actuator |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Registration | Certified · 2025-01-09 |
| Languages | tr-TR, en-US |
| Catalog entry | M-029A_H-10.2000.2000-64-O0234_HP-9D00-20-4439-O0234_CI-MM.2D20.2Dxx.2D211-1 |
| Fingerprint | 4439 |
| SHA-256 | f89888528d05fe77033da6dabf58d71762196dd9ef641e48c4e30b21ec0e3755 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Switch, Shutter, Valve, Fan Coil, v1.0 2.0
| Application number | $9D00 |
|---|---|
| Version | 2.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 148 |
| Group objects | 39 |
Group objects (39)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | General | Manual Operation Status | 1 Bit | 1.11 state | CRT |
| 0 | Output - {{Arg_Switch}} | Switch | 1 Bit | 1.1 switch | CW |
| 0 | Output - {{Arg_Shutter_Start_Output}} ... {{Arg_Shutter_End_Output}} | Shutter/Blinds Move | 1 Bit | 1.8 up/down | CW |
| 0 | Output - {{Arg_ValveMotor_Start_Output}} ... {{Arg_ValveMotor_End_Output}} | Valve Heating Control Value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 0 | Output - {{Arg_ValveMotor_Start_Output}} ... {{Arg_ValveMotor_End_Output}} | Valve Cooling Control Value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 0 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Automatic Mode On/Off | 1 Bit | DPT.1 | CW |
| 0 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Manual Mode On/Off | 1 Bit | DPT.1 | CW |
| 1 | General | Stop Manual Operation | 1 Bit | 1.1 switch | CW |
| 1 | Output - {{Arg_Switch}} | Switch Status | 1 Bit | 1.1 switch | CRT |
| 1 | Output - {{Arg_Shutter_Start_Output}} ... {{Arg_Shutter_End_Output}} | Shutter/Blinds Stop/Step | 1 Bit | 1.7 step | CW |
| 1 | Output - {{Arg_ValveMotor_Start_Output}} ... {{Arg_ValveMotor_End_Output}} | Valve Status Value | 1 Byte | 5.1 percentage (0..100%) | CT |
| 1 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Heating Control Value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 1 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Heating/Cooling Control Value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 2 | General | Request Status Values | 1 Bit | 1.1 switch | CW |
| 2 | Output - {{Arg_Switch}} | Switch Threshold Input | 1 Byte | 5.1 percentage (0..100%) | CW |
| 2 | Output - {{Arg_Shutter_Start_Output}} ... {{Arg_Shutter_End_Output}} | Shutter/Blinds Scene | 1 Byte | 17.1 scene number | CW |
| 2 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Cooling Control Value | 1 Byte | 5.1 percentage (0..100%) | CW |
| 3 | General | Central Switch Input | 1 Bit | 1.1 switch | CW |
| 3 | Output - {{Arg_Switch}} | Switch Permanent On | 1 Bit | 1.1 switch | CW |
| 3 | Output - {{Arg_Shutter_Start_Output}} ... {{Arg_Shutter_End_Output}} | Shutter/Blinds Move to Position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 3 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Heating/Cooling Mode Selection | 1 Bit | 1.100 cooling/heating | CW |
| 4 | General | Central Shutter/Blinds Move Input | 1 Bit | 1.8 up/down | CW |
| 4 | Output - {{Arg_Switch}} | Switch Logic AND Input | 1 Bit | 1.2 boolean | CW |
| 4 | Output - {{Arg_Switch}} | Switch Logic OR Input | 1 Bit | 1.2 boolean | CW |
| 4 | Output - {{Arg_Switch}} | Switch Logic TOGGLE Input | 1 Bit | 1.2 boolean | CW |
| 4 | Output - {{Arg_Shutter_Start_Output}} ... {{Arg_Shutter_End_Output}} | Shutter/Blinds Position Status | 1 Byte | 5.1 percentage (0..100%) | CT |
| 4 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Window Contact | 1 Bit | 1.1 switch | CW |
| 5 | General | Central Shutter/Blinds Stop/Step Input | 1 Bit | 1.7 step | CW |
| 5 | Output - {{Arg_Switch}} | Switch Scene | 1 Byte | 17.1 scene number | CW |
| 5 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Automatic Mode Status | 1 Bit | 1.2 boolean | CRT |
| 5 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Manual Mode Status | 1 Bit | 1.2 boolean | CRT |
| 6 | General | Safety Priority for Switches | 1 Bit | 1.5 alarm | CW |
| 6 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil On/Off Status | 1 Bit | 1.2 boolean | CRT |
| 7 | General | Wind Alarm for Shutter/Blinds | 1 Bit | 1.5 alarm | CWT |
| 7 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Heating/Cooling Mode Status | 1 Bit | 1.100 cooling/heating | CRT |
| 8 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Speed Set | 1 Byte | 5.1 percentage (0..100%) | CW |
| 8 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Speed Set | 1 Byte | 5.100 fan stage (0..255) | CW |
| 9 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Speed Status | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 9 | Output - {{Arg_FanCoil_Start_Output}} ... {{Arg_FanCoil_End_Output}} | Fan Coil Speed Status | 1 Byte | 5.100 fan stage (0..255) | CRT |
Parameters (100)
| Parameter | Type | Default |
|---|---|---|
| Allow Manual Operation | list | Enable |
| Safety Priority Object for Switches | list | Disable |
| Wind Alarm for Shutter/Blinds | list | Disable |
| Device Model | list | 4 Channel |
| Function Block 1 | list | Shutter/Blinds |
| Function Block 2 | list | Switch |
| Function Block 3 | list | Shutter/Blinds |
| Function Block 5 | list | Shutter/Blinds |
| Function Block 6 | list | Switch |
| Function Block 7 | list | Shutter/Blinds |
| Function Block 8 | list | Switch |
| Function Block 9 | list | Shutter/Blinds |
| Function Block 10 | list | Switch |
| Function Block 11 | list | Shutter/Blinds |
| Function Block 12 | list | Switch |
| Function Block 13 | list | Shutter/Blinds |
| Function Block 14 | list | Switch |
| Function Block 15 | list | Shutter/Blinds |
| Function Block 16 | list | Switch |
| Function Block 17 | list | Shutter/Blinds |
| Function Block 18 | list | Switch |
| Function Block 19 | list | Shutter/Blinds |
| Function Block 20 | list | Switch |
| Function Block 21 | list | Shutter/Blinds |
| Function Block 22 | list | Switch |
| Function Block 23 | list | Shutter/Blinds |
| Function Block 24 | list | Switch |
| Manual Operation Timeout | list | Never |
| Start Up Delay | unsignedInt 3…255 | 3 |
| Function Block 4 | list | Switch |
| IO_Status | unsignedInt 0…255 | 0 |
| Output Type | list | Normally Open |
| Scenes | list | No |
| Reaction at Bus Voltage Fail | list | No Reaction |
| Reaction at Safety Priority | list | No Reaction |
| Receive Data in 8-bit | list | No |
| Reaction End of Safety Priority | list | No Reaction |
| Threshold (included) | unsignedInt 1…255 | 25 |
| Scene 5 State | list | No Reaction |
| Scene 1 State | list | No Reaction |
| Scene 2 State | list | No Reaction |
| Scene 3 State | list | No Reaction |
| Scene 4 State | list | No Reaction |
| Scene 1 Number | list | Scene 1 |
| Scene 2 Number | list | Scene 1 |
| Scene 3 Number | list | Scene 1 |
| Scene 4 Number | list | Scene 1 |
| Scene 5 Number | list | Scene 1 |
| Time Function | list | No Function |
| Logic Function | list | NO LOGIC |
| Send Status | list | After a Change |
| Act with Central Switch Object | list | No |
| Time Function | list | No |
| Logic Function | list | No |
| Switch On Delay | unsignedInt 0…6500 | 0 |
| Switch Off Delay | unsignedInt 0…6500 | 0 |
| Lighting Time | unsignedInt 1…6500 | 1 |
| Flashing On Time | unsignedInt 2…6500 | 2 |
| Flashing Off Time | unsignedInt 2…6500 | 2 |
| Pre_State | list | Disable |
| Act with Central Blind Object | list | Disable |
| Scenes | list | Disable |
| Slat Operation | list | Disable |
| Act at Wind Alarm | list | No Reaction |
| Act After Wind Alarm | list | No Reaction |
| Slat Step Time | list | 400 |
| Travel Time | unsignedInt 1…6500 | 60 |
| Blind_State | unsignedInt 0…255 | 0 |
| Pre_Move_To_Pos | unsignedInt 0…255 | 0 |
| Pause Time | list | 250 |
| Drive Time | unsignedInt 0…65535 | 10 |
| Valve Name | list | Heating Valve |
| Drive Time | unsignedInt 1…6500 | 1 |
| Valve_State | unsignedInt 0…255 | 0 |
| Next_State | list | Disable |
| Fan Speed Output | list | One Output for Each Stage |
| Fan Automatic Means | list | Auto=1, Manual=0 |
| Automatic Control Inputs | list | 1 |
| Select Control Input | list | Largest Value |
| Fan Speed | list | Keep Position |
| Fan Speed Data Type | list | DPT 5.100 (Fan Stage) |
| Window Contact Action | list | Keep Position |
| Fan Speed on Bus Voltage Fail | list | Keep Position |
| Fan Start Delay | unsignedInt 0…255 | 0 |
| Fan Acceleration Time | unsignedInt 0…255 | 0 |
| Fan Speed Change Delay | list | 0 |
| Fan - 1 Start at | unsignedInt 1…253 | 25 |
| Fan - 2 Start at | unsignedInt 2…254 | 105 |
| Pre_Control_Value | unsignedInt 0…255 | 0 |
| Fan_State | unsignedInt 0…3 | 0 |
| Pre_Fan_State | unsignedInt 0…3 | 0 |
| Next_Fan_State | unsignedInt 0…3 | 0 |
| Actual_Mode | unsignedInt 0…1 | 0 |
| H_C_Mode | unsignedInt 0…1 | 0 |
| Window_Contact | unsignedInt 0…1 | 0 |
| Hysteresis | unsignedInt 0…15 | 0 |
| Fan Speed on Startup | list | Automatic |
| Fan - 3 Start at | unsignedInt 3…255 | 180 |
| Pre_Control_Val | unsignedInt 0…255 | 0 |
| Next_fan_state | unsignedInt 0…3 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switch, Shutter, Valve, Fan Coil, v1.0 2.0 latest | $9D00 | 4439 | 2026-11-25 | 142 KB | Download |
About this file
This is the official ETS product database for the MM Electro MM-20-xx-211 Combo Actuator / Multi-Channel (MM-20-xx-211), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MM Electro
- MM-20-xx-111 Combo Actuator / Multi-Channel MM-20-xx-111
- MM1-20-1612-11 Multi Actuator Snow1 16A 16 Output, 12 Digital Input MM1-20-1612-11
- MM1-20-2412-11 Multi Actuator Snow1 16A 24 Output, 12 Digital Input MM1-20-2412-11
- MM1-30-03-111 Universal Interface / 3-Channel MM1-30-03-111
- MM1-30-06-111 Universal Interface / 6-Channel MM1-30-06-111
- MM1-30-0x-111 Universal Interface / 9-Channel MM1-30-09-111
- MM1-30-LM-111 Logic Module MM1-30-LM-111
- MM1-4T-XX Dora Series KNX Room Controller x/y Gang/Button Sensor MM1-4T-XX
- MM1-4X-XX Dora Series x/y Gang KNX Keypad with Sensor MM1-4X-XX
- MM1-50-111-xx Multi Sensör MM1-50-111-xx
- MM1-50-xxx-211 Multi Sensor MM1-50-xxx-211
- MM1-50-xxx-212 Advanced Multi Sensor MM1-50-xxx-212