Switch actuator UP/230/16 629993
Merten · Order number 629993 · 4.1 Switch Actuator, 1-gang › 4.1.01 Flush-mounted UP
629993
Download .knxprod Switch Logic Time Scene Dis. Prio. Init. 4810/1.1 1.1 · 164 KB
Product
| Manufacturer | Merten |
|---|---|
| Product name | Switch actuator UP/230/16 |
| Order number | 629993 |
| Hardware | Schaltaktor UP/230/16 |
| Medium | Twisted Pair |
| Rail mounted | No |
| Registration | Certified · 2006-03-17 |
| Languages | en-US, de-DE |
| Catalog entry | M-000C_H-629993-1_HP-4810-11-02CF_CI-629993-1 |
| Fingerprint | 02CF |
| SHA-256 | 263f78cd34cdcc895a52628d154a9c31cecb1759c3059ffd556876e0daac638d |
| First seen | 2026-11-25 |
| Markets | Argentina, Australia, Austria, Germany, Uruguay |
Application program: Switch Logic Time Scene Dis. Prio. Init. 4810/1.1 1.1
| Application number | $4810 |
|---|---|
| Version | 1.1 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | No |
| Parameters | 1060 |
| Group objects | 56 |
Group objects (56)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Switch object | Channel 1 | 1 Bit | CW | |
| 1 | Priority object | Channel 1 | 2 Bit | CW | |
| 1 | Logic object | Channel 1 | 1 Bit | CW | |
| 2 | Locking object | Channel 1 | 1 Bit | CW | |
| 3 | Status object | Channel 1 | 1 Bit | CRT | |
| 3 | Status feedback object | Channel 1 | 1 Bit | CRT | |
| 3 | Status object | Channel 1 | 1 Bit | CR | |
| 4 | Switch object | Channel 2 | 1 Bit | CW | |
| 5 | Priority object | Channel 2 | 2 Bit | CW | |
| 5 | Logic object | Channel 2 | 1 Bit | CW | |
| 5 | Priority object | Channel 2 | 1 Bit | CW | |
| 6 | Locking object | Channel 2 | 1 Bit | CW | |
| 7 | Status object | Channel 2 | 1 Bit | CRT | |
| 7 | Status feedback object | Channel 2 | 1 Bit | CRT | |
| 7 | Status object | Channel 2 | 1 Bit | CR | |
| 8 | Switch object | Channel 3 | 1 Bit | CW | |
| 9 | Logic object | Channel 3 | 1 Bit | CW | |
| 9 | Priority object | Channel 3 | 2 Bit | CW | |
| 10 | Locking object | Channel 3 | 1 Bit | CW | |
| 11 | Status object | Channel 3 | 1 Bit | CRT | |
| 11 | Status feedback object | Channel 3 | 1 Bit | CRT | |
| 12 | Switch object | Channel 4 | 1 Bit | CW | |
| 13 | Priority object | Channel 4 | 2 Bit | CW | |
| 13 | Logic object | Channel 4 | 1 Bit | CW | |
| 14 | Locking object | Channel 4 | 1 Bit | CW | |
| 15 | Status object | Channel 4 | 1 Bit | CR | |
| 15 | Status feedback object | Channel 4 | 1 Bit | CRT | |
| 15 | Status object | Channel 4 | 1 Bit | CRT | |
| 16 | Switch object | Channel 5 | 1 Bit | CW | |
| 17 | Logic object | Channel 5 | 1 Bit | CW | |
| 17 | Priority object | Channel 5 | 2 Bit | CW | |
| 18 | Locking object | Channel 5 | 1 Bit | CW | |
| 19 | Status object | Channel 5 | 1 Bit | CRT | |
| 19 | Status feedback object | Channel 5 | 1 Bit | CRT | |
| 20 | Switch object | Channel 6 | 1 Bit | CW | |
| 21 | Logic object | Channel 6 | 1 Bit | CW | |
| 21 | Priority object | Channel 6 | 2 Bit | CW | |
| 22 | Locking object | Channel 6 | 1 Bit | CW | |
| 23 | Status object | Channel 6 | 1 Bit | CRT | |
| 23 | Status feedback object | Channel 6 | 1 Bit | CRT | |
| 23 | Status object | Channel 6 | 1 Bit | CR | |
| 24 | Switch object | Channel 7 | 1 Bit | CW | |
| 25 | Logic object | Channel 7 | 1 Bit | CW | |
| 25 | Priority object | Channel 7 | 2 Bit | CW | |
| 26 | Locking object | Channel 7 | 1 Bit | CW | |
| 27 | Status object | Channel 7 | 1 Bit | CRT | |
| 27 | Status feedback object | Channel 7 | 1 Bit | CRT | |
| 28 | Switch object | Channel 8 | 1 Bit | CW | |
| 29 | Logic object | Channel 8 | 1 Bit | CW | |
| 29 | Priority object | Channel 8 | 2 Bit | CW | |
| 30 | Locking object | Channel 8 | 1 Bit | CW | |
| 31 | Status object | Channel 8 | 1 Bit | CR | |
| 31 | Status feedback object | Channel 8 | 1 Bit | CRT | |
| 31 | Status object | Channel 8 | 1 Bit | CRT | |
| 32 | Central object | Central function | 1 Bit | CW | |
| 33 | Scene object | Scene | 1 Byte | CW |
Parameters (77)
| Parameter | Type | Default |
|---|---|---|
| Device selection | list | 8-fold switch actuator |
| Status information | list | switched off |
| Higher priority function | list | none |
| Locking function | list | switched off |
| Relay operation | list | make contact |
| Staircase lighting function | list | switched off |
| ON delay | list | switched off |
| OFF delay | list | switched off |
| Relay state after bus voltage failure | list | no change |
| Relay state after bus voltage recovery | list | as for bus voltage failure |
| Relay state after ETS download | list | as for bus voltage recovery |
| Time base for ON delay | list | 1 s |
| Factor for ON delay (1-255) | unsignedInt 1…255 | 3 |
| ON delay is | list | not retriggerable |
| Time base for OFF delay | list | 1 s |
| Factor for OFF delay (1-255) | unsignedInt 1…255 | 120 |
| OFF delay is | list | not retriggerable |
| Base for staircase timer | list | 1 s |
| Factor for staircase timer (1-255) | unsignedInt 1…255 | 85 |
| Staircase timer is | list | retriggerable |
| Staircase timer | list | with manual OFF |
| Warning at end of staircase timer | list | OFF |
| Number of warnings | list | 1 |
| Warning time (1-255), factor * 1 s | unsignedInt 1…255 | 30 |
| Time for interruptions (1-20) factor * 100 ms | unsignedInt 1…20 | 5 |
| Time for interruptions (1-20) factor * 100 m | unsignedInt 1…20 | 5 |
| Time between warnings (1-255) factor * 1 s | unsignedInt 1…255 | 5 |
| Logic operation ON | list | logic operation |
| Type of logic operation | list | AND |
| Value of logic object after bus voltage recovery | list | 0 |
| Reaction after priority | list | follows switching object |
| Function of priority after bus voltage recovery | list | no active priority |
| Priority ON | list | logic operation |
| Disable function for | list | Locking object=1 |
| Value of disable object after bus voltage recovery | list | 0 |
| Reaction at blocking | list | no change |
| Reaction when released: Only when higher priority function inactive | list | no change |
| Reaction when released: Only when higher priority function inactive | list | follows switching object |
| Time for interruptions (1-20) factor * 1 s | unsignedInt 1…20 | 5 |
| Central function is | list | not active |
| Channel 1: | list | no reaction at 0 or 1 |
| Channel 2 (only if Ch. 1 is not a changeover contact) | list | no reaction at 0 or 1 |
| Channel 3: | list | no reaction at 0 or 1 |
| Channel 4 (only if Ch. 3 is not a changeover contact) | list | no reaction at 0 or 1 |
| Channel 5: | list | no reaction at 0 or 1 |
| Channel 6 (only if Ch. 5 is not a changeover contact) | list | no reaction at 0 or 1 |
| Channel 7: | list | no reaction at 0 or 1 |
| Channel 8 (only if Ch. 7 is not a changeover contact) | list | no reaction at 0 or 1 |
| Scenes are | list | not active |
| Scene 1 is | list | retrievable |
| Scene 2 is | list | not active |
| Scene 3 is | list | not active |
| Scene 4 is | list | not active |
| Scene 5 is | list | not active |
| Scene 6 is | list | not active |
| Scene 7 is | list | not active |
| Scene 8 is | list | not active |
| Learn Scene 1 | list | ON |
| Channel 1 | list | no change |
| Channel 2 (only if Ch. 1 is not a changeover contact) | list | no change |
| Channel 3 | list | no change |
| Channel 4 (only if Ch. 3 is not a changeover contact) | list | no change |
| Channel 5 | list | no change |
| Channel 6 (only if Ch. 5 is not a changeover contact) | list | no change |
| Channel 7 | list | no change |
| Channel 8 (only if Ch. 7 is not a changeover contact) | list | no change |
| Learn Scene 2 | list | ON |
| Learn Scene 3 | list | ON |
| Learn Scene 4 | list | ON |
| Learn Scene 5 | list | ON |
| Learn Scene 6 | list | ON |
| Learn Scene 7 | list | ON |
| Learn Scene 8 | list | ON |
| Limitation of telegram rate | list | 30 telegrams per 17 s |
| Display of ETS download | list | 1 |
| Flashing interval base | list | 100 ms |
| Flashing interval factor (5-255) | unsignedInt 5…255 | 10 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switch Logic Time Scene Dis. Prio. Init. 4810/1.1 1.1 latest | $4810 | 02CF | 2026-11-25 | 164 KB | Download |
About this file
This is the official ETS product database for the Merten Switch actuator UP/230/16 (629993), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Merten
- KNX Switch Act. 16A FM w.2 Inputs MEG6003-0001
- TCU UP/PI with 4-gang push-button interface 6167xx
- TCU UP/PI with 4-gang push-button interface 6168xx
- TCU UP/PI with 4-gang push-button interface 6169xx
- Push-button 1-gang plus 6171xx
- Push-button 2-gang plus 6172xx
- Push-button 4-gang plus 6174xx
- Push-button 4-gang plus with IR receiver 6175xx
- INSTABUS push-button module 1-gang, System M 625199
- INSTABUS push-button module 2-gang, System M 625299
- INSTABUS push-button module 1-gang, System Design 626199
- INSTABUS push-button module 2-gang, System Design 626299