KAA-4R4V-10S Switch,Dimming Actuator,4-fold,10A,MDRC KAA-4R4V-10S
MEAN WELL Enterprises Co. Ltd. · Order number KAA-4R4V-10S · Output › Switch , Dimming Actuator
Download .knxprod Switching, Blinds, Shutter, Dimming 4f 2.0 · 221 KB
Product
| Manufacturer | MEAN WELL Enterprises Co. Ltd. |
|---|---|
| Product name | KAA-4R4V-10S Switch,Dimming Actuator,4-fold,10A,MDRC |
| Order number | KAA-4R4V-10S |
| Hardware | KAA-4R4V-S Series Switch,Dimming Actuator,4-fold |
| Medium | Twisted Pair |
| Bus current (mA) | 14 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Certified · 2021-11-04 |
| Languages | de-DE, fr-FR, en-US, it-IT |
| Catalog entry | M-0162_H-KAA.2D4R4V.2DS-2_HP-0009-20-98C4_CI-KAA.2D4R4V.2D10S-1 |
| Fingerprint | 98C4 |
| SHA-256 | 911a01875160689cf8f36bcce757643bd6ced0162cd639959b1b7ba7f9d9444e |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Switching, Blinds, Shutter, Dimming 4f 2.0
| Application number | $0009 |
|---|---|
| Version | 2.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 682 |
| Group objects | 167 |
Group objects (167)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Central Function | Manual control | 1 Bit | 1.3 enable | CW |
| 2 | Central Function | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 3 | Central Function | Dim absolutely | 1 Byte | 5.1 percentage (0..100%) | CW |
| 4 | Central Function | Operation | 1 Bit | 1.11 state | CRT |
| 5 | Channel 1 | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 6 | Channel 1 | State On/Off | 1 Bit | 1.11 state | CRT |
| 7 | Channel A | Additional Switch On/Off | 1 Bit | 1.1 switch | CW |
| 8 | Channel A | Additional Switch state | 1 Bit | 1.11 state | CRT |
| 9 | Channel 1 | Dim relatively | 4 Bit | 3.7 dimming control | CW |
| 10 | Channel 1 | Dim absolutely | 1 Byte | 5.1 percentage (0..100%) | CW |
| 11 | Channel 1 | State Dimm Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 12 | Channel 1 | Scene | 1 Byte | 17.1 scene number | CW |
| 12 | Channel 1 | Scene | 1 Byte | 18.1 scene control | CW |
| 13 | Channel 1 | Automatic 1 | 1 Bit | 1.1 switch | CW |
| 14 | Channel 1 | Automatic 2 | 1 Bit | 1.1 switch | CW |
| 15 | Channel 1 | Automatic 3 | 1 Bit | 1.1 switch | CW |
| 16 | Channel 1 | Automatic 4 | 1 Bit | 1.1 switch | CW |
| 17 | Channel 1 | Block I | 1 Bit | 1.3 enable | CW |
| 18 | Channel 1 | Block II | 1 Bit | 1.3 enable | CW |
| 19 | Channel 1 | Staircase light | 1 Bit | 1.1 switch | CW |
| 20 | Channel 1 | Staircase light with time | 2 Bytes | 7.5 time (s) | CW |
| 21 | Channel 1 | Prewarning | 1 Bit | 1.5 alarm | CRT |
| 22 | Channel 1 | Permanent ON | 1 Bit | 1.1 switch | CW |
| 23 | Channel 2 | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 24 | Channel 2 | State On/Off | 1 Bit | 1.11 state | CRT |
| 25 | Channel B | Additional Switch On/Off | 1 Bit | 1.1 switch | CW |
| 26 | Channel B | Additional Switch state | 1 Bit | 1.11 state | CRT |
| 27 | Channel 2 | Dim relatively | 4 Bit | 3.7 dimming control | CW |
| 28 | Channel 2 | Dim absolutely | 1 Byte | 5.1 percentage (0..100%) | CW |
| 29 | Channel 2 | State Dimm Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 30 | Channel 2 | Scene | 1 Byte | 17.1 scene number | CW |
| 30 | Channel 2 | Scene | 1 Byte | 18.1 scene control | CW |
| 31 | Channel 2 | Automatic 1 | 1 Bit | 1.1 switch | CW |
| 32 | Channel 2 | Automatic 2 | 1 Bit | 1.1 switch | CW |
| 33 | Channel 2 | Automatic 3 | 1 Bit | 1.1 switch | CW |
| 34 | Channel 2 | Automatic 4 | 1 Bit | 1.1 switch | CW |
| 35 | Channel 2 | Block I | 1 Bit | 1.3 enable | CW |
| 36 | Channel 2 | Block II | 1 Bit | 1.3 enable | CW |
| 37 | Channel 2 | Staircase light | 1 Bit | 1.1 switch | CW |
| 38 | Channel 2 | Staircase light with time | 2 Bytes | 7.5 time (s) | CW |
| 39 | Channel 2 | Prewarning | 1 Bit | 1.5 alarm | CRT |
| 40 | Channel 2 | Permanent ON | 1 Bit | 1.1 switch | CW |
| 41 | Channel 3 | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 42 | Channel 3 | State On/Off | 1 Bit | 1.11 state | CRT |
| 43 | Channel C | Additional Switch On/Off | 1 Bit | 1.1 switch | CW |
| 44 | Channel C | Additional Switch state | 1 Bit | 1.11 state | CRT |
| 45 | Channel 3 | Dim relatively | 4 Bit | 3.7 dimming control | CW |
| 46 | Channel 3 | Dim absolutely | 1 Byte | 5.1 percentage (0..100%) | CW |
| 47 | Channel 3 | State Dimm Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 48 | Channel 3 | Scene | 1 Byte | 17.1 scene number | CW |
| 48 | Channel 3 | Scene | 1 Byte | 18.1 scene control | CW |
| 49 | Channel 3 | Automatic 1 | 1 Bit | 1.1 switch | CW |
| 50 | Channel 3 | Automatic 2 | 1 Bit | 1.1 switch | CW |
| 51 | Channel 3 | Automatic 3 | 1 Bit | 1.1 switch | CW |
| 52 | Channel 3 | Automatic 4 | 1 Bit | 1.1 switch | CW |
| 53 | Channel 3 | Block I | 1 Bit | 1.3 enable | CW |
| 54 | Channel 3 | Block II | 1 Bit | 1.3 enable | CW |
| 55 | Channel 3 | Staircase light | 1 Bit | 1.1 switch | CW |
| 56 | Channel 3 | Staircase light with time | 2 Bytes | 7.5 time (s) | CW |
| 57 | Channel 3 | Prewarning | 1 Bit | 1.5 alarm | CRT |
| 58 | Channel 3 | Permanent ON | 1 Bit | 1.1 switch | CW |
| 59 | Channel 4 | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 60 | Channel 4 | State On/Off | 1 Bit | 1.11 state | CRT |
| 61 | Channel D | Additional Switch On/Off | 1 Bit | 1.1 switch | CW |
| 62 | Channel D | Additional Switch state | 1 Bit | 1.11 state | CRT |
| 63 | Channel 4 | Dim relatively | 4 Bit | 3.7 dimming control | CW |
| 64 | Channel 4 | Dim absolutely | 1 Byte | 5.1 percentage (0..100%) | CW |
| 65 | Channel 4 | State Dimm Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 66 | Channel 4 | Scene | 1 Byte | 17.1 scene number | CW |
| 66 | Channel 4 | Scene | 1 Byte | 18.1 scene control | CW |
| 67 | Channel 4 | Automatic 1 | 1 Bit | 1.1 switch | CW |
| 68 | Channel 4 | Automatic 2 | 1 Bit | 1.1 switch | CW |
| 69 | Channel 4 | Automatic 3 | 1 Bit | 1.1 switch | CW |
| 70 | Channel 4 | Automatic 4 | 1 Bit | 1.1 switch | CW |
| 71 | Channel 4 | Block I | 1 Bit | 1.3 enable | CW |
| 72 | Channel 4 | Block II | 1 Bit | 1.3 enable | CW |
| 73 | Channel 4 | Staircase light | 1 Bit | 1.1 switch | CW |
| 74 | Channel 4 | Staircase light with time | 2 Bytes | 7.5 time (s) | CW |
| 75 | Channel 4 | Prewarning | 1 Bit | 1.5 alarm | CRT |
| 76 | Channel 4 | Permanent ON | 1 Bit | 1.1 switch | CW |
| 77 | Central Function | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 78 | Central Function | Slats adjustment/stop | 1 Bit | 1.7 step | CW |
| 79 | Central Function | Stop | 1 Bit | 1.17 trigger | CW |
| 80 | Central Function | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 81 | Central Function | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 82 | Automatic Ⅰ | Automatic position 1 | 1 Bit | 1.1 switch | CW |
| 83 | Automatic Ⅰ | Automatic position 2 | 1 Bit | 1.1 switch | CW |
| 84 | Automatic Ⅰ | Automatic position 3 | 1 Bit | 1.1 switch | CW |
| 85 | Automatic Ⅰ | Automatic position 4 | 1 Bit | 1.1 switch | CW |
| 86 | Automatic Ⅱ | Automatic position 1 | 1 Bit | 1.1 switch | CW |
| 87 | Automatic Ⅱ | Automatic position 2 | 1 Bit | 1.1 switch | CW |
| 88 | Automatic Ⅱ | Automatic position 3 | 1 Bit | 1.1 switch | CW |
| 89 | Automatic Ⅱ | Automatic position 4 | 1 Bit | 1.1 switch | CW |
| 90 | Channel A/B | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 90 | Channel A/B | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 91 | Channel A/B | Slats adjustment/stop | 1 Bit | 1.7 step | CW |
| 91 | Channel A/B | Short term operation/Stop | 1 Bit | 1.7 step | CW |
| 92 | Channel A/B | Stop | 1 Bit | 1.17 trigger | CW |
| 93 | Channel A/B | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 94 | Channel A/B | Status current position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 95 | Channel A/B | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 96 | Channel A/B | Status upper position | 1 Bit | 1.11 state | CRT |
| 97 | Channel A/B | Status lower position | 1 Bit | 1.11 state | CRT |
| 98 | Channel A/B | Status lock/alarm | 1 Bit | 1.11 state | CRT |
| 99 | Channel A/B | Status of movement up | 1 Bit | 1.11 state | CRT |
| 99 | Channel A/B | Status of movement | 1 Bit | 1.11 state | CRT |
| 100 | Channel A/B | Status of movement down | 1 Bit | 1.11 state | CRT |
| 101 | Channel A/B | Start driving to reference | 1 Bit | 1.8 up/down | CW |
| 102 | Channel A/B | Scene | 1 Byte | 17.1 scene number | CW |
| 102 | Channel A/B | Scene | 1 Byte | 18.1 scene control | CW |
| 103 | Channel A/B | Driver to position | 1 Bit | 1.10 start/stop | CW |
| 104 | Channel A/B | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 105 | Channel A/B | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 106 | Channel A/B | Wind alarm | 1 Bit | 1.5 alarm | CW |
| 107 | Channel A/B | Rain alarm | 1 Bit | 1.5 alarm | CW |
| 108 | Channel A/B | Frost alarm | 1 Bit | 1.5 alarm | CW |
| 109 | Channel A/B | Normal Block | 1 Bit | 1.3 enable | CW |
| 110 | Channel A/B | Diagnosis text | 14 Bytes | 16.0 Character String (ASCII) | CRT |
| 111 | Channel A/B | Window contact | 1 Bit | 1.2 boolean | CW |
| 111 | Channel A/B | Window contact 1 | 1 Bit | 1.2 boolean | CW |
| 112 | Channel A/B | Window contact 2 | 1 Bit | 1.2 boolean | CW |
| 113 | Channel A/B | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 114 | Channel A/B | Block function | 1 Bit | 1.3 enable | CW |
| 115 | Channel A/B | Block central object | 1 Bit | 1.3 enable | CW |
| 116 | Channel C/D | Blinds up/down | 1 Bit | 1.8 up/down | CW |
| 116 | Channel C/D | Shutter up/down | 1 Bit | 1.8 up/down | CW |
| 117 | Channel C/D | Slats adjustment/stop | 1 Bit | 1.7 step | CW |
| 117 | Channel C/D | Short term operation/Stop | 1 Bit | 1.7 step | CW |
| 118 | Channel C/D | Stop | 1 Bit | 1.17 trigger | CW |
| 119 | Channel C/D | Status current position | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 120 | Channel C/D | Status current position of slats | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 121 | Channel C/D | Status current direction | 1 Bit | 1.8 up/down | CRT |
| 122 | Channel C/D | Status upper position | 1 Bit | 1.11 state | CRT |
| 123 | Channel C/D | Status lower position | 1 Bit | 1.11 state | CRT |
| 124 | Channel C/D | Status lock/alarm | 1 Bit | 1.11 state | CRT |
| 125 | Channel C/D | Status of movement up | 1 Bit | 1.11 state | CRT |
| 125 | Channel C/D | Status of movement | 1 Bit | 1.11 state | CRT |
| 126 | Channel C/D | Status of movement down | 1 Bit | 1.11 state | CRT |
| 127 | Channel C/D | Start driving to reference | 1 Bit | 1.8 up/down | CW |
| 128 | Channel C/D | Scene | 1 Byte | 17.1 scene number | CW |
| 128 | Channel C/D | Scene | 1 Byte | 18.1 scene control | CW |
| 129 | Channel C/D | Driver to position | 1 Bit | 1.10 start/stop | CW |
| 130 | Channel C/D | Absolute position | 1 Byte | 5.1 percentage (0..100%) | CW |
| 131 | Channel C/D | Absolute position of slats | 1 Byte | 5.1 percentage (0..100%) | CW |
| 132 | Channel C/D | Wind alarm | 1 Bit | 1.5 alarm | CW |
| 133 | Channel C/D | Rain alarm | 1 Bit | 1.5 alarm | CW |
| 134 | Channel C/D | Frost alarm | 1 Bit | 1.5 alarm | CW |
| 135 | Channel C/D | Normal Block | 1 Bit | 1.3 enable | CW |
| 136 | Channel C/D | Diagnosis text | 14 Bytes | 16.0 Character String (ASCII) | CRT |
| 137 | Channel C/D | Window contact | 1 Bit | 1.2 boolean | CW |
| 137 | Channel C/D | Window contact 1 | 1 Bit | 1.2 boolean | CW |
| 138 | Channel C/D | Window contact 2 | 1 Bit | 1.2 boolean | CW |
| 139 | Channel C/D | Block absolute position mode | 1 Bit | 1.3 enable | CW |
| 140 | Channel C/D | Block function | 1 Bit | 1.3 enable | CW |
| 141 | Channel C/D | Block central object | 1 Bit | 1.3 enable | CW |
| 142 | Channel A/B | Up/Down in automatic control | 1 Bit | 1.8 up/down | CW |
| 143 | Channel A/B | Short Term in automatic control | 1 Bit | 1.7 step | CW |
| 144 | Channel A/B | Stop in automatic control | 1 Bit | 1.17 trigger | CW |
| 145 | Channel A/B | Absolute Position in automatic control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 146 | Channel A/B | Absolute Slat in automatic control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 147 | Channel A/B | Lock in automatic control | 1 Bit | 1.3 enable | CW |
| 148 | Channel C/D | Up/Down in automatic control | 1 Bit | 1.8 up/down | CW |
| 149 | Channel C/D | Short Term in automatic control | 1 Bit | 1.7 step | CW |
| 150 | Channel C/D | Stop in automatic control | 1 Bit | 1.17 trigger | CW |
| 151 | Channel C/D | Absolute Position in automatic control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 152 | Channel C/D | Absolute Slat in automatic control | 1 Byte | 5.1 percentage (0..100%) | CW |
| 153 | Channel C/D | Lock in automatic control | 1 Bit | 1.3 enable | CW |
Parameters (219)
| Parameter | Type | Default |
|---|---|---|
| Prewarning | list | not active |
| Light value | list | 100% light |
| Starting behavior | list | On-value setting |
| Central function | list | not active |
| Light value | list | 10% light |
| Duration for staircase light | unsignedInt 1…30000 | 90 |
| Behavior at Block I=value “1” | list | Off |
| Scene number | list | 6 |
| Scene number | list | 3 |
| Automatic function | list | not active |
| Light value | list | off |
| Dimming Channel 3/C | list | not active |
| Behavior of relay when bus power off | list | no change |
| Dimming curve | list | Linear |
| Scene H | list | not active |
| Value of start up | list | 50% |
| Value of dimming down | list | 20% |
| Automatic function 2-Exposure value | list | off |
| Transition time to new brightness | unsignedInt 1…240 | 10 |
| Automatic function 1-Exposure value | list | off |
| Behavior at Block II=value “0” | list | Off |
| Off delay | unsignedInt 0…30000 | 0 |
| Send "operation" cyclic(0=not active) | unsignedInt 0…30000 | 0 |
| Send dim value after change | list | at dim end |
| Scene A | list | not active |
| Dimming Channel 4/D | list | not active |
| Staircase light | list | not active |
| Automatic function 3-Exposure value | list | off |
| Behavior at Block II=value “1” | list | Off |
| Additional relay switch off delay | unsignedInt 0…30000 | 0 |
| Scene D | list | not active |
| Scene G | list | not active |
| Automatic function 4-Exposure value | list | off |
| Additional relay switch on delay | unsignedInt 0…30000 | 0 |
| Minimum light | list | 1% |
| Relay switch mode | list | Dimming with relay control |
| Light value | list | 50% light |
| Scenes | list | not active |
| Scene number | list | 1 |
| Behavior of relay after bus power up | list | no change |
| Scene number | list | 4 |
| Behavior at Block I=value “0” | list | Light value |
| Behavior of relay after bus power up | list | Off |
| When permanent OFF | list | Dimm down off |
| Scene number | list | 7 |
| Behavior at Block I=value “1” | list | Light value |
| Prewarning duration in | unsignedInt 1…30000 | 10 |
| Extension | list | not active |
| On delay | unsignedInt 0…30000 | 0 |
| Dim speed for absolute dimming(0=Jump) | unsignedInt 0…120 | 5 |
| Manual switching off | list | not active |
| Learn scene | list | not active |
| Scene C | list | not active |
| Send On/Off state | list | at change |
| Scene F | list | not active |
| Dim speed for relative dimming | unsignedInt 1…120 | 5 |
| On speed | list | 2 s |
| Eco Mode,switch LED’s off after | list | not active |
| Off speed | list | 2 s |
| Scene number | list | 2 |
| Behavior at Block II=value “0” | list | Light value |
| Output mode | list | 0-10V Output |
| Scene number | list | 5 |
| Behavior at Block II=value “1” | list | Light value |
| Behavior after bus power up | list | Last value |
| Maximum light | list | 100% |
| Brightness value during permanent ON | list | 50% |
| Scene number | list | 8 |
| Scene B | list | not active |
| Scene E | list | not active |
| Behavior at Block I=value “0” | list | Off |
| Switch status when bus power off | list | Contact opened |
| Manual operation | list | active |
| Dimming Channel 1/A | list | not active |
| Behavior of relay when bus power off | list | Off |
| Dimming Channel 2/B | list | not active |
| Startup timeout | list | 2 s |
| Release time for Block II (value “1” to “0”) (0 min = not active) | unsignedInt 0…600 | 0 |
| Release time for Block I (value “1” to “0”) (0 min = not active) | unsignedInt 0…600 | 0 |
| Invert Block I input | list | not active |
| Invert Block II input | list | not active |
| Parameter1 | list | PidHardwareType |
| PidVersion | unsignedInt 0…65535 | 8320 |
| Channel A/B for Shutter/Blinds | list | not active |
| Automatic Block Ⅰ | list | not active |
| Automatic Block Ⅱ | list | not active |
| Channel C/D for Shutter/Blinds | list | not active |
| Action at block(value=1) | list | no action |
| Action at frost alarm | list | no action |
| Action at rain alarm | list | no action |
| Action at reset of block | list | no action |
| Action at reset of alarm | list | no action |
| Action at wind alarm | list | no action |
| Advanced block | list | not active |
| Air function over window contacts | list | not active |
| Alarm order | list | Wind alarm,Rain alarm,Frost alarm,Block function |
| Automatic functions | list | not active |
| Used automatic objects | list | Block Ⅰ |
| Automatic position 1 | list | not active |
| Action at withdrawal of automatic position(value=0) | list | not active |
| Height position | list | 0% |
| Move to position(value=1) | list | always |
| Position of slats | list | 0% |
| Automatic position 2 | list | not active |
| Automatic position 3 | list | not active |
| Action at withdrawal of automatic psition(value=0) | list | not active |
| Automatic position 4 | list | not active |
| Behavior after power up | list | not active |
| Behavior if window open | list | execute air funciton |
| Block absolute position | list | not active |
| Block automaticly "Absolute position" by using up/down movement | list | not active |
| Block air function | list | not active |
| Block automatic position | list | not active |
| Block central object | list | not active |
| Block central objects automatically with "down" | list | not active |
| Object "Block functions" | list | not active |
| Block manual operation | list | not active |
| Block Scene | list | not active |
| Block up/down movement | list | not active |
| Cancel blocking if upper position is reached | list | not active |
| Cancel blocking of central objects with "up" | list | not active |
| Central objects | list | only absolute position and up/down |
| Diagnosis as character | list | send at request |
| Time for Down Movement | unsignedInt 5…1000 | 45 |
| Extension of movement time | list | 5% |
| Frost alarm | list | not active |
| Monitoring time(0=not active) | unsignedInt 0…120 | 0 |
| Height position for alarm/block | list | 0% |
| Action after movement to reference | list | no action |
| 1Bit object for "Move to position" | list | not active |
| Action at value 0 | list | not active |
| Action at value 1 | list | always |
| Position of blinds | list | 0% |
| Movement time | unsignedInt 5…1000 | 45 |
| Time for Up/Down movement | list | same |
| Normal Block function | list | not active |
| Object "Block absolute position" | list | not active |
| Object for absolute position | list | not active |
| Object for movement status | list | not active |
| Pause on reverse | unsignedInt 100…2000 | 500 |
| Position of slats at end of driving (Move Down) | list | 100% |
| Rain alarm | list | not active |
| Object for reference drive | list | not active |
| Scene | list | not active |
| Movement time for short term operation | unsignedInt 50…5000 | 200 |
| Short term operation | list | not active |
| Function Channel A/B | list | Blinds |
| Function Channel C/D | list | Blinds |
| Scene A block function | list | not active |
| Scene A height position | list | 0% |
| Scene number A | list | not active |
| Scene A position of slats | list | 0% |
| Scene B block function | list | not active |
| Scene B height position | list | 0% |
| Scene number B | list | not active |
| Scene B position of slats | list | 0% |
| Scene C block function | list | not active |
| Scene C height position | list | 0% |
| Scene number C | list | not active |
| Scene C position of slats | list | 0% |
| Scene D block function | list | not active |
| Scene D height position | list | 0% |
| Scene number D | list | not active |
| Scene D position of slats | list | 0% |
| Scene E block function | list | not active |
| Scene E height position | list | 0% |
| Scene number E | list | not active |
| Scene E position of slats | list | 0% |
| Scene F block function | list | not active |
| Scene F height position | list | 0% |
| Scene number F | list | not active |
| Scene F position of slats | list | 0% |
| Scene G block function | list | not active |
| Scene G height position | list | 0% |
| Scene number G | list | not active |
| Scene G position of slats | list | 0% |
| Scene H block function | list | not active |
| Scene H height position | list | 0% |
| Scene number H | list | not active |
| Scene H position of slats | list | 0% |
| Slat adjustment time | unsignedInt 100…10000 | 1200 |
| Slats position for "open" | list | 0% |
| Slats position for alarm/block | list | 0% |
| Slats position for "tilted" | list | 0% |
| Status current blocking/alarm | list | not active |
| Status current direction/position up/down | list | not active |
| Status current position | list | not active |
| Step time for slats adjustment | unsignedInt 50…5000 | 200 |
| Switch-Off delay motor | unsignedInt 0…500 | 200 |
| Switch-On delay motor | unsignedInt 0…500 | 200 |
| Interchange connections for motor Up/Down | list | normal |
| Up/Down movement can stop (single object control) | list | not active |
| Time for Up Movement | unsignedInt 5…1000 | 45 |
| Set condition for "open" | list | value 0 |
| Set condition for "open" | list | contact 1="0"/contact 2="0" |
| Set condition for "titled" | list | contact 1="0"/contact 2="0" |
| Wind alarm | list | not active |
| Action if window is closed | list | no action |
| Window contacts | list | 1 contact for "open" window |
| Action if window is "open" | list | not active |
| Blinds position for "open" | list | 0% |
| Action if window is "tilted" | list | not active |
| Blinds position for "tilted" | list | 0% |
| Position of shutter | list | 0% |
| Shutter position for "open" | list | 0% |
| Shutter position for "tilted" | list | 0% |
| Position change report threshold | list | Change 5% |
| Position change report threshold | list | at the end |
| Automatic Control Function | list | not active |
| Automatic locking | list | at object value "0" |
| Behavior on deactivating the automatic locking via object value | list | accept current automatic mode position |
| Time base for deactivation period in automatic mode | list | 1 s |
| Factor for deactivation time in automatic mode(1-255) | unsignedInt 1…255 | 60 |
| Automatic locking | list | inactive |
| Behavior on deactivating the automatic locking via object value | list | no reaction |
| Time base for deactivation period in automatic mode | list | 1 min |
| Factor for deactivation time in automatic mode(1-255) | unsignedInt 1…255 | 1 |
| Reaction in automatic mode on receipt of a manual object value | list | automatic mode remains enabled |
| Reaction in automatic mode on receipt of a manual object value | list | automatic mode temporarily locked |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switching, Blinds, Shutter, Dimming 4f 2.0 latest | $0009 | 98C4 | 2026-11-25 | 221 KB | Download |
About this file
This is the official ETS product database for the MEAN WELL Enterprises Co. Ltd. KAA-4R4V-10S Switch,Dimming Actuator,4-fold,10A,MDRC (KAA-4R4V-10S), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MEAN WELL Enterprises Co. Ltd.
- KAA-4R4V-S Switch,Dimming Actuator,4-fold,16A,MDRC KAA-4R4V-S
- KAA-8R-10S Universal Actuator,8-fold,10A,MDRC KAA-8R-10S
- KAA-8R-S Universal Actuator,8-fold,16A,MDRC KAA-8R-S
- DLC-02 KNX DALI Gateway DLC-02-KN
- KNX-20E-640 Power Supply (230V/640mA) KNX-20E-640
- KNX-40E-1280 Power Supply (230V/1280mA) KNX-40E-1280
- KNX-40E-1280D Power Supply (230V/1280mA) KNX-40E-1280D
- TP Line Repeater KSC-01L KSC-01L
- KNX USB-Interface KSI-01U
- KNX IP TP Router KSR-01IP
- LCM-25KN 25W LED Driver with KNX interface LCM-25KN
- LCM-40KN 40W LED Driver with KNX interface LCM-40KN