MEAN WELL Enterprises Co. Ltd. KNX-40E-1280D KNX-40E-1280D Power Supply (230V/1280mA)

KNX-40E-1280D Power Supply (230V/1280mA) KNX-40E-1280D

MEAN WELL Enterprises Co. Ltd. · Order number KNX-40E-1280D · System Devices › Power Supply Unit

KNX power supply unit with integrated choke 1280mA

Download .knxprod Power Supply,Diagnosis,1280mA 1.1 · 174 KB

Product

ManufacturerMEAN WELL Enterprises Co. Ltd.
Product nameKNX-40E-1280D Power Supply (230V/1280mA)
Order numberKNX-40E-1280D
Product textKNX-40E-1280D Power Supply(230V/1280mA)
HardwareKNX-40E-1280D Power Supply (230V/1280mA)
MediumTwisted Pair
Bus current (mA)1280
Rail mountedYes
Width (mm)72
Device kindPowerSupply, Choke
RegistrationCertified · 2019-04-29
Languagesde-DE, fr-FR, en-US, es-ES, it-IT, pl-PL, ru-RU, zh-CN, cs-CZ, sk-SK, pt-PT, fi-FI, nl-NL, da-DK, sv-SE, nb-NO
Catalog entryM-0162_H-KNX.2D40E.2D1280D-1_HP-0004-11-F245_CI-KNX.2D40E.2D1280D-4
FingerprintF245
SHA-2563e4ea16d89cecabf6f68a92efbce4db28ea8ffdd1789279fb3cdb7281afc0030
First seen2026-11-25
Markets69 markets

Application program: Power Supply,Diagnosis,1280mA 1.1

Application number$0004
Version1.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters115
Group objects41
Group objects (41)
NoNameFunctionSizeDPTFlags
1HeartbeatInformation1 Bit1.17 triggerCRT
2Power supply onInformation1 Bit1.17 triggerCRT
3Send measurementsRequest1 Bit1.1 switchCW
4Clear all dataRequest1 Bit1.1 switchCW
5Send calculationsRequest1 Bit1.1 switchCW
6Bus resetReset Request1 Bit1.1 switchCWU
7Total working timeAnalysis4 Bytes13.100 time lag (s)CRT
8Time from last start up Analysis4 Bytes13.100 time lag (s)CRT
9The number of bus restart timesAnalysis2 Bytes7.1 pulsesCRT
10The number of devices startup timesAnalysis2 Bytes7.1 pulsesCRT
11Output voltage measuredMeasurement4 Bytes14.27 electric potential (V)CRT
11Output voltage measuredMeasurement2 Bytes9.20 voltage (mV)CRT
12Output voltage alarmAlarm1 Bit1.5 alarmCRT
13Output current measuredMeasurement4 Bytes14.19 electric current (A)CRT
13Output current measuredMeasurement2 Bytes7.12 current (mA)CRT
13Output current measuredMeasurement2 Bytes9.21 current (mA)CRT
14Output current alarmAlarm1 Bit1.5 alarmCRT
15Device temperature measuredMeasurement2 Bytes9.1 temperature (°C)CRT
16Device temperature alarmAlarm1 Bit1.5 alarmCRT
17Maximum output current during tracking periodMeasurement4 Bytes14.19 electric current (A)CRT
17Maximum output current during tracking periodMeasurement2 Bytes7.12 current (mA)CRT
17Maximum output current during tracking periodMeasurement2 Bytes9.21 current (mA)CRT
18Maximum device temperature during tracking periodMeasurement2 Bytes9.1 temperature (°C)CRT
19Busload measuredMeasurement1 Byte5.4 percentage (0..255%)CRT
20Busload alarmAlarm1 Bit1.5 alarmCRT
21The number of overload timesAnalysis2 Bytes7.1 pulsesCRT
22Overload durationAnalysis4 Bytes13.100 time lag (s)CRT
23The number of short circuits timesAnalysis2 Bytes7.1 pulsesCRT
24Time load detachedAnalysis4 Bytes13.100 time lag (s)CRT
25Alarm 1Group Alarm1 Bit1.5 alarmCRT
26Count 1Group Alarm2 Bytes7.1 pulsesCRT
27Duration 1Group Alarm4 Bytes13.100 time lag (s)CRT
28Alarm 2Group Alarm1 Bit1.5 alarmCRT
29Count 2Group Alarm2 Bytes7.1 pulsesCRT
30Duration 2Group Alarm4 Bytes13.100 time lag (s)CRT
31Alarm 3Group Alarm1 Bit1.5 alarmCRT
32Count 3Group Alarm2 Bytes7.1 pulsesCRT
33Duration 3Group Alarm4 Bytes13.100 time lag (s)CRT
34Alarm 4Group Alarm1 Bit1.5 alarmCRT
35Count 4Group Alarm2 Bytes7.1 pulsesCRT
36Duration 4Group Alarm4 Bytes13.100 time lag (s)CRT
Parameters (73)
ParameterTypeDefault
Threshold SettingunsignedInt 10…16001280
Short Circuits Count Cyclic SendinglistOFF
Maximum Temperature SendlistDo not send
Busload Difference SendingunsignedInt 1…10010
Alarm Counter Cyclic SendinglistOFF
Behaviour On BusLoad Alarm DeactivelistSend 0
Time Load Detached Duration RecordlistDisable
Alarm Counter Difference SendingunsignedInt 0…5000
Voltage Cyclic SendinglistOFF
Maximum Current Object Typelist4 Byte (DPT 14)
Measurement SourcelistOutput Current
Bus Restart Times CountlistDisable
Temperature MeasurementlistDisable
Temperature Cyclic SendinglistOFF
Startup Times Count ReadlistDisable
Current Cyclic SendinglistOFF
Overload Count FunctionlistDisable
Overload Duration Difference SendingunsignedInt 0…360000
Behaviour On Alarm ActivelistSend 1
Maximum Tracking PeriodunsignedInt 10…360001800
Voltage MeasurementlistDisable
Current MeasurementlistDisable
Temperature ThresholdunsignedInt 0…11070
Current HysteresisunsignedInt 10…128010
Reset TypelistWith 1
Delay Time to Send Object "Power supply on"listNo delay
Maximum Current TrackinglistDisable
Heartbeat TimeunsignedInt 10…3600060
Current Object Typelist4 Byte (DPT 14)
Alarm TypelistLimit Exceeded
Overload Duration FunctionlistDisable
BusLoad MeasurementlistDisable
Voltage Object Typelist4 Byte (DPT 14)
Behaviour On Temperature Alarm ActivelistSend 1
Hysteresis SettingunsignedInt 10…128010
Alarm Duration Difference SendingunsignedInt 0…28000000
Temperature HysteresisunsignedInt 0…401
Alarm FunctionlistDisable
Operating Time Difference SendingunsignedInt 0…28000000
BusLoad AlarmlistDisable
Operating Time DurationlistDisable
Maximum Current SendlistDo not send
Overload Count Cyclic SendinglistOFF
Short Circuits Count FunctionlistDisable
Total Working Time Difference SendingunsignedInt 0…28000000
Current AlarmlistDisable
Total Working Time ReadlistDisable
Behaviour On Alarm DeactivelistSend 0
Temperature Difference SendinglistOFF
Overload Count Difference SendingunsignedInt 0…10000
Busload Alarm HysteresisunsignedInt 1…7010
Short Circuits Count Difference SendingunsignedInt 0…5000
Busload Alarm ThresholdunsignedInt 1…10080
Behaviour On BusLoad Alarm ActivelistSend 1
Behaviour On Current Alarm ActivelistSend 1
Current Difference SendinglistOFF
Startup Times Cyclic SendinglistOFF
Voltage AlarmlistDisable
Busload Cyclic SendinglistOFF
Behaviour On Temperature Alarm DeactivelistSend 0
Behaviour On Current Alarm DeactivelistSend 0
Behaviour On Voltage Alarm DeactivelistSend 0
Temperature AlarmlistDisable
Current ThresholdunsignedInt 10…160010
Behaviour On Voltage Alarm ActivelistSend 1
Maximum TemperaturelistDisable
Hysteresis SettingunsignedInt 5…905
Threshold SettingunsignedInt 28…3231
Restart Times Cyclic SendinglistOFF
Threshold SettingunsignedInt 40…9570
Hysteresis SettingunsignedInt 1…65
PIDHardwarelistPidHardware
PidVersionunsignedInt 0…655354160

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Power Supply,Diagnosis,1280mA 1.1 latest$0004F2452026-11-25174 KBDownload

About this file

This is the official ETS product database for the MEAN WELL Enterprises Co. Ltd. KNX-40E-1280D Power Supply (230V/1280mA) (KNX-40E-1280D), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.