KNX-40E-1280D Power Supply (230V/1280mA) KNX-40E-1280D
MEAN WELL Enterprises Co. Ltd. · Order number KNX-40E-1280D · System Devices › Power Supply Unit
KNX power supply unit with integrated choke 1280mA
Download .knxprod Power Supply,Diagnosis,1280mA 1.1 · 174 KB
Product
| Manufacturer | MEAN WELL Enterprises Co. Ltd. |
|---|---|
| Product name | KNX-40E-1280D Power Supply (230V/1280mA) |
| Order number | KNX-40E-1280D |
| Product text | KNX-40E-1280D Power Supply(230V/1280mA) |
| Hardware | KNX-40E-1280D Power Supply (230V/1280mA) |
| Medium | Twisted Pair |
| Bus current (mA) | 1280 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Device kind | PowerSupply, Choke |
| Registration | Certified · 2019-04-29 |
| Languages | de-DE, fr-FR, en-US, es-ES, it-IT, pl-PL, ru-RU, zh-CN, cs-CZ, sk-SK, pt-PT, fi-FI, nl-NL, da-DK, sv-SE, nb-NO |
| Catalog entry | M-0162_H-KNX.2D40E.2D1280D-1_HP-0004-11-F245_CI-KNX.2D40E.2D1280D-4 |
| Fingerprint | F245 |
| SHA-256 | 3e4ea16d89cecabf6f68a92efbce4db28ea8ffdd1789279fb3cdb7281afc0030 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Power Supply,Diagnosis,1280mA 1.1
| Application number | $0004 |
|---|---|
| Version | 1.1 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 115 |
| Group objects | 41 |
Group objects (41)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Heartbeat | Information | 1 Bit | 1.17 trigger | CRT |
| 2 | Power supply on | Information | 1 Bit | 1.17 trigger | CRT |
| 3 | Send measurements | Request | 1 Bit | 1.1 switch | CW |
| 4 | Clear all data | Request | 1 Bit | 1.1 switch | CW |
| 5 | Send calculations | Request | 1 Bit | 1.1 switch | CW |
| 6 | Bus reset | Reset Request | 1 Bit | 1.1 switch | CWU |
| 7 | Total working time | Analysis | 4 Bytes | 13.100 time lag (s) | CRT |
| 8 | Time from last start up | Analysis | 4 Bytes | 13.100 time lag (s) | CRT |
| 9 | The number of bus restart times | Analysis | 2 Bytes | 7.1 pulses | CRT |
| 10 | The number of devices startup times | Analysis | 2 Bytes | 7.1 pulses | CRT |
| 11 | Output voltage measured | Measurement | 4 Bytes | 14.27 electric potential (V) | CRT |
| 11 | Output voltage measured | Measurement | 2 Bytes | 9.20 voltage (mV) | CRT |
| 12 | Output voltage alarm | Alarm | 1 Bit | 1.5 alarm | CRT |
| 13 | Output current measured | Measurement | 4 Bytes | 14.19 electric current (A) | CRT |
| 13 | Output current measured | Measurement | 2 Bytes | 7.12 current (mA) | CRT |
| 13 | Output current measured | Measurement | 2 Bytes | 9.21 current (mA) | CRT |
| 14 | Output current alarm | Alarm | 1 Bit | 1.5 alarm | CRT |
| 15 | Device temperature measured | Measurement | 2 Bytes | 9.1 temperature (°C) | CRT |
| 16 | Device temperature alarm | Alarm | 1 Bit | 1.5 alarm | CRT |
| 17 | Maximum output current during tracking period | Measurement | 4 Bytes | 14.19 electric current (A) | CRT |
| 17 | Maximum output current during tracking period | Measurement | 2 Bytes | 7.12 current (mA) | CRT |
| 17 | Maximum output current during tracking period | Measurement | 2 Bytes | 9.21 current (mA) | CRT |
| 18 | Maximum device temperature during tracking period | Measurement | 2 Bytes | 9.1 temperature (°C) | CRT |
| 19 | Busload measured | Measurement | 1 Byte | 5.4 percentage (0..255%) | CRT |
| 20 | Busload alarm | Alarm | 1 Bit | 1.5 alarm | CRT |
| 21 | The number of overload times | Analysis | 2 Bytes | 7.1 pulses | CRT |
| 22 | Overload duration | Analysis | 4 Bytes | 13.100 time lag (s) | CRT |
| 23 | The number of short circuits times | Analysis | 2 Bytes | 7.1 pulses | CRT |
| 24 | Time load detached | Analysis | 4 Bytes | 13.100 time lag (s) | CRT |
| 25 | Alarm 1 | Group Alarm | 1 Bit | 1.5 alarm | CRT |
| 26 | Count 1 | Group Alarm | 2 Bytes | 7.1 pulses | CRT |
| 27 | Duration 1 | Group Alarm | 4 Bytes | 13.100 time lag (s) | CRT |
| 28 | Alarm 2 | Group Alarm | 1 Bit | 1.5 alarm | CRT |
| 29 | Count 2 | Group Alarm | 2 Bytes | 7.1 pulses | CRT |
| 30 | Duration 2 | Group Alarm | 4 Bytes | 13.100 time lag (s) | CRT |
| 31 | Alarm 3 | Group Alarm | 1 Bit | 1.5 alarm | CRT |
| 32 | Count 3 | Group Alarm | 2 Bytes | 7.1 pulses | CRT |
| 33 | Duration 3 | Group Alarm | 4 Bytes | 13.100 time lag (s) | CRT |
| 34 | Alarm 4 | Group Alarm | 1 Bit | 1.5 alarm | CRT |
| 35 | Count 4 | Group Alarm | 2 Bytes | 7.1 pulses | CRT |
| 36 | Duration 4 | Group Alarm | 4 Bytes | 13.100 time lag (s) | CRT |
Parameters (73)
| Parameter | Type | Default |
|---|---|---|
| Threshold Setting | unsignedInt 10…1600 | 1280 |
| Short Circuits Count Cyclic Sending | list | OFF |
| Maximum Temperature Send | list | Do not send |
| Busload Difference Sending | unsignedInt 1…100 | 10 |
| Alarm Counter Cyclic Sending | list | OFF |
| Behaviour On BusLoad Alarm Deactive | list | Send 0 |
| Time Load Detached Duration Record | list | Disable |
| Alarm Counter Difference Sending | unsignedInt 0…500 | 0 |
| Voltage Cyclic Sending | list | OFF |
| Maximum Current Object Type | list | 4 Byte (DPT 14) |
| Measurement Source | list | Output Current |
| Bus Restart Times Count | list | Disable |
| Temperature Measurement | list | Disable |
| Temperature Cyclic Sending | list | OFF |
| Startup Times Count Read | list | Disable |
| Current Cyclic Sending | list | OFF |
| Overload Count Function | list | Disable |
| Overload Duration Difference Sending | unsignedInt 0…36000 | 0 |
| Behaviour On Alarm Active | list | Send 1 |
| Maximum Tracking Period | unsignedInt 10…36000 | 1800 |
| Voltage Measurement | list | Disable |
| Current Measurement | list | Disable |
| Temperature Threshold | unsignedInt 0…110 | 70 |
| Current Hysteresis | unsignedInt 10…1280 | 10 |
| Reset Type | list | With 1 |
| Delay Time to Send Object "Power supply on" | list | No delay |
| Maximum Current Tracking | list | Disable |
| Heartbeat Time | unsignedInt 10…36000 | 60 |
| Current Object Type | list | 4 Byte (DPT 14) |
| Alarm Type | list | Limit Exceeded |
| Overload Duration Function | list | Disable |
| BusLoad Measurement | list | Disable |
| Voltage Object Type | list | 4 Byte (DPT 14) |
| Behaviour On Temperature Alarm Active | list | Send 1 |
| Hysteresis Setting | unsignedInt 10…1280 | 10 |
| Alarm Duration Difference Sending | unsignedInt 0…2800000 | 0 |
| Temperature Hysteresis | unsignedInt 0…40 | 1 |
| Alarm Function | list | Disable |
| Operating Time Difference Sending | unsignedInt 0…2800000 | 0 |
| BusLoad Alarm | list | Disable |
| Operating Time Duration | list | Disable |
| Maximum Current Send | list | Do not send |
| Overload Count Cyclic Sending | list | OFF |
| Short Circuits Count Function | list | Disable |
| Total Working Time Difference Sending | unsignedInt 0…2800000 | 0 |
| Current Alarm | list | Disable |
| Total Working Time Read | list | Disable |
| Behaviour On Alarm Deactive | list | Send 0 |
| Temperature Difference Sending | list | OFF |
| Overload Count Difference Sending | unsignedInt 0…1000 | 0 |
| Busload Alarm Hysteresis | unsignedInt 1…70 | 10 |
| Short Circuits Count Difference Sending | unsignedInt 0…500 | 0 |
| Busload Alarm Threshold | unsignedInt 1…100 | 80 |
| Behaviour On BusLoad Alarm Active | list | Send 1 |
| Behaviour On Current Alarm Active | list | Send 1 |
| Current Difference Sending | list | OFF |
| Startup Times Cyclic Sending | list | OFF |
| Voltage Alarm | list | Disable |
| Busload Cyclic Sending | list | OFF |
| Behaviour On Temperature Alarm Deactive | list | Send 0 |
| Behaviour On Current Alarm Deactive | list | Send 0 |
| Behaviour On Voltage Alarm Deactive | list | Send 0 |
| Temperature Alarm | list | Disable |
| Current Threshold | unsignedInt 10…1600 | 10 |
| Behaviour On Voltage Alarm Active | list | Send 1 |
| Maximum Temperature | list | Disable |
| Hysteresis Setting | unsignedInt 5…90 | 5 |
| Threshold Setting | unsignedInt 28…32 | 31 |
| Restart Times Cyclic Sending | list | OFF |
| Threshold Setting | unsignedInt 40…95 | 70 |
| Hysteresis Setting | unsignedInt 1…6 | 5 |
| PIDHardware | list | PidHardware |
| PidVersion | unsignedInt 0…65535 | 4160 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Power Supply,Diagnosis,1280mA 1.1 latest | $0004 | F245 | 2026-11-25 | 174 KB | Download |
About this file
This is the official ETS product database for the MEAN WELL Enterprises Co. Ltd. KNX-40E-1280D Power Supply (230V/1280mA) (KNX-40E-1280D), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MEAN WELL Enterprises Co. Ltd.
- KNX-20E-640 Power Supply (230V/640mA) KNX-20E-640
- KNX-40E-1280 Power Supply (230V/1280mA) KNX-40E-1280
- TP Line Repeater KSC-01L KSC-01L
- KNX USB-Interface KSI-01U
- KNX IP TP Router KSR-01IP
- DLC-02 KNX DALI Gateway DLC-02-KN
- KAA-4R4V-10S Switch,Dimming Actuator,4-fold,10A,MDRC KAA-4R4V-10S
- KAA-4R4V-S Switch,Dimming Actuator,4-fold,16A,MDRC KAA-4R4V-S
- KAA-8R-10S Universal Actuator,8-fold,10A,MDRC KAA-8R-10S
- KAA-8R-S Universal Actuator,8-fold,16A,MDRC KAA-8R-S
- LCM-25KN 25W LED Driver with KNX interface LCM-25KN
- LCM-40KN 40W LED Driver with KNX interface LCM-40KN