AZI-0616.01 Actuator 6-fold with active power measurement AZI-0616.01

MDT technologies GmbH · Order number AZI-0616.01 · Actuators › Actuators with active power meter

Industrial version 230VAC, 16A, 200µF C-Load

Download .knxprod Switching, Staircase, Active power measurement 6f 1.2 · 174 KB

Product

ManufacturerMDT technologies GmbH
Product nameAZI-0616.01 Actuator 6-fold with active power measurement
Order numberAZI-0616.01
Product textAZI-0616.01 Switch Actuator 6-fold with active power measurement
HardwareSchaltaktor 6-fach mit Wirkleistungszähler
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)142.3
RegistrationCertified · 2015-03-19
Languagesde-DE, en-US
Catalog entryM-0083_H-27-0_HP-0011-12-C950_CI-AZI.2D0616.2E01-1
FingerprintC950
SHA-2566f7e595518243f779c4ad8601e87c324f64b1f6a06efd5ebdc18bafa3995c21b
First seen2026-11-25
Markets69 markets

Application program: Switching, Staircase, Active power measurement 6f 1.2

Application number$0011
Version1.2
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters1065
Group objects386
Group objects (386)
NoNameFunctionSizeDPTFlags
0Channel ASwitch On/Off1 Bit1.1 switchCW
1Channel AStaircase1 Bit1.1 switchCW
2Channel ALock1 Bit1.3 enableCW
3Channel AScene1 Byte17.1 scene numberCW
4Channel AState1 Bit1.11 stateCRT
5Channel ALogic 11 Bit1.2 booleanCW
6Channel ALogic 21 Bit1.2 booleanCW
7Channel A: Active power meterActive power4 Bytes14.56 power (W)CRT
7Channel A: Active power meterActive power2 Bytes9.24 power (kW)CRT
8Channel A: Active power meterCurrent value2 Bytes7.12 current (mA)CRT
8Channel A: Active power meterCurrent value2 Bytes9.21 current (mA)CRT
8Channel A: Active power meterCurrent value4 Bytes14.19 electric current (A)CRT
9Channel A: Active power meterVoltage value4 Bytes14.27 electric potential (V)CRT
10Channel A: Advanced power measurementApparent power4 Bytes14.56 power (W)CRT
10Channel A: Advanced power measurementApparent power2 Bytes9.24 power (kW)CRT
10Channel A: Advanced power measurementReactive power4 Bytes14.56 power (W)CRT
10Channel A: Advanced power measurementReactive power2 Bytes9.24 power (kW)CRT
10Channel A: Advanced power measurementPower factor cos phi4 Bytes14.57 power factor (cos Φ)CRT
11Channel A: Active power meterExceeding of load1 Bit1.11 stateCRT
12Channel A: Active power meterFalling below of load1 Bit1.11 stateCRT
13Channel A: Active power meterExceedance of current1 Bit1.11 stateCRT
14Channel A: Active power meterLower deviation of current1 Bit1.11 stateCRT
15Channel A: Active power meterExceedance of voltage1 Bit1.11 stateCRT
16Channel A: Active power meterLower deviation of voltage1 Bit1.11 stateCRT
17Channel A: Intermediate meterActive energy (Wh)4 Bytes13.10 active energy (Wh)CRT
17Channel A: Intermediate meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
18Channel A: Intermediate meterDisplay costs in cents4 BytesCRT
18Channel A: Intermediate meterDisplay costs in cents2 BytesCRT
18Channel A: Intermediate meterDisplay costs in euro4 BytesCRT
18Channel A: Intermediate meterDisplay costs in euro2 BytesCRT
19Channel A: Intermediate meterMeter reading for day4 Bytes13.10 active energy (Wh)CRT
19Channel A: Intermediate meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
20Channel A: Intermediate meterMeter reading for night4 Bytes13.10 active energy (Wh)CRT
20Channel A: Intermediate meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
21Channel A: Intermediate meterReset1 Bit1.3 enableCW
22Channel A: Main meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
23Channel A: Main meterDisplay costs in cents4 BytesCRT
23Channel A: Main meterDisplay costs in cents2 BytesCRT
23Channel A: Main meterDisplay costs in euro4 BytesCRT
23Channel A: Main meterDisplay costs in euro2 BytesCRT
24Channel A: Main meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
25Channel A: Main meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
26Channel A: Main meterReset1 Bit1.3 enableCW
27Channel A: CounterEvent A1 Bit1.10 start/stopCT
28Channel A: CounterEvent B1 Bit1.10 start/stopCT
29Channel A: Operating hours counterResponse operating hours2 Bytes7.7 time (h)CRT
29Channel A: Operating hours counterTime to the next service2 Bytes7.7 time (h)CRT
30Channel A: Operating hours counterReset operating hours1 Bit1.1 switchCW
30Channel A: Operating hours counterReset service1 Bit1.1 switchCW
31Channel A: Operating hours counterService required1 Bit1.1 switchCT
32Dummy 321 Bit
33Channel A: Operating hours counterResponse operating hours4 Bytes13.100 time lag (s)CRT
33Channel A: Operating hours counterTime to the next service4 Bytes13.100 time lag (s)CRT
34Dummy 341 Bit
35Dummy 351 Bit
36Channel BSwitch On/Off1 Bit1.1 switchCW
37Channel BStaircase1 Bit1.1 switchCW
38Channel BLock1 Bit1.3 enableCW
39Channel BScene1 Byte17.1 scene numberCW
40Channel BState1 Bit1.11 stateCRT
41Channel BLogic 11 Bit1.2 booleanCW
42Channel BLogic 21 Bit1.2 booleanCW
43Channel B: Active power meterActive power4 Bytes14.56 power (W)CRT
43Channel B: Active power meterActive power2 Bytes9.24 power (kW)CRT
44Channel B: Active power meterCurrent value2 Bytes7.12 current (mA)CRT
44Channel B: Active power meterCurrent value2 Bytes9.21 current (mA)CRT
44Channel B: Active power meterCurrent value4 Bytes14.19 electric current (A)CRT
45Channel B: Active power meterVoltage value4 Bytes14.27 electric potential (V)CRT
46Channel B: Advanced power measurementApparent power4 Bytes14.56 power (W)CRT
46Channel B: Advanced power measurementApparent power2 Bytes9.24 power (kW)CRT
46Channel B: Advanced power measurementReactive power4 Bytes14.56 power (W)CRT
46Channel B: Advanced power measurementReactive power2 Bytes9.24 power (kW)CRT
46Channel B: Advanced power measurementPower factor cos phi4 Bytes14.57 power factor (cos Φ)CRT
47Channel B: Active power meterExceeding of load1 Bit1.11 stateCRT
48Channel B: Active power meterFalling below of load1 Bit1.11 stateCRT
49Channel B: Active power meterExceedance of current1 Bit1.11 stateCRT
50Channel B: Active power meterLower deviation of current1 Bit1.11 stateCRT
51Channel B: Active power meterExceedance of voltage1 Bit1.11 stateCRT
52Channel B: Active power meterLower deviation of voltage1 Bit1.11 stateCRT
53Channel B: Intermediate meterActive energy (Wh)4 Bytes13.10 active energy (Wh)CRT
53Channel B: Intermediate meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
54Channel B: Intermediate meterDisplay costs in cents4 BytesCRT
54Channel B: Intermediate meterDisplay costs in cents2 BytesCRT
54Channel B: Intermediate meterDisplay costs in euro4 BytesCRT
54Channel B: Intermediate meterDisplay costs in euro2 BytesCRT
55Channel B: Intermediate meterMeter reading for day4 Bytes13.10 active energy (Wh)CRT
55Channel B: Intermediate meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
56Channel B: Intermediate meterMeter reading for night4 Bytes13.10 active energy (Wh)CRT
56Channel B: Intermediate meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
57Channel B: Intermediate meterReset1 Bit1.3 enableCW
58Channel B: Main meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
59Channel B: Main meterDisplay costs in cents4 BytesCRT
59Channel B: Main meterDisplay costs in cents2 BytesCRT
59Channel B: Main meterDisplay costs in euro4 BytesCRT
59Channel B: Main meterDisplay costs in euro2 BytesCRT
60Channel B: Main meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
61Channel B: Main meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
62Channel B: Main meterReset1 Bit1.3 enableCW
63Channel B: CounterEvent A1 Bit1.10 start/stopCT
64Channel B: CounterEvent B1 Bit1.10 start/stopCT
65Channel B: Operating hours counterResponse operating hours2 Bytes7.7 time (h)CRT
65Channel B: Operating hours counterTime to the next service2 Bytes7.7 time (h)CRT
66Channel B: Operating hours counterReset operating hours1 Bit1.1 switchCW
66Channel B: Operating hours counterReset service1 Bit1.1 switchCW
67Channel B: Operating hours counterService required1 Bit1.1 switchCT
68Dummy 681 Bit
69Channel B: Operating hours counterResponse operating hours4 Bytes13.100 time lag (s)CRT
69Channel B: Operating hours counterTime to the next service4 Bytes13.100 time lag (s)CRT
70Dummy 704 Bytes
71Dummy 714 Bytes
72Channel CSwitch On/Off1 Bit1.1 switchCW
73Channel CStaircase1 Bit1.1 switchCW
74Channel CLock1 Bit1.3 enableCW
75Channel CScene1 Byte17.1 scene numberCW
76Channel CState1 Bit1.11 stateCRT
77Channel CLogic 11 Bit1.2 booleanCW
78Channel CLogic 21 Bit1.2 booleanCW
79Channel C: Active power meterActive power4 Bytes14.56 power (W)CRT
79Channel C: Active power meterActive power2 Bytes9.24 power (kW)CRT
80Channel C: Active power meterCurrent value2 Bytes7.12 current (mA)CRT
80Channel C: Active power meterCurrent value2 Bytes9.21 current (mA)CRT
80Channel C: Active power meterCurrent value4 Bytes14.19 electric current (A)CRT
81Channel C: Active power meterVoltage value4 Bytes14.27 electric potential (V)CRT
82Channel C: Advanced power measurementApparent power4 Bytes14.56 power (W)CRT
82Channel C: Advanced power measurementApparent power2 Bytes9.24 power (kW)CRT
82Channel C: Advanced power measurementReactive power4 Bytes14.56 power (W)CRT
82Channel C: Advanced power measurementReactive power2 Bytes9.24 power (kW)CRT
82Channel C: Advanced power measurementPower factor cos phi4 Bytes14.57 power factor (cos Φ)CRT
83Channel C: Active power meterExceeding of load1 Bit1.11 stateCRT
84Channel C: Active power meterFalling below of load1 Bit1.11 stateCRT
85Channel C: Active power meterExceedance of current1 Bit1.11 stateCRT
86Channel C: Active power meterLower deviation of current1 Bit1.11 stateCRT
87Channel C: Active power meterExceedance of voltage1 Bit1.11 stateCRT
88Channel C: Active power meterLower deviation of voltage1 Bit1.11 stateCRT
89Channel C: Intermediate meterActive energy (Wh)4 Bytes13.10 active energy (Wh)CRT
89Channel C: Intermediate meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
90Channel C: Intermediate meterDisplay costs in cents4 BytesCRT
90Channel C: Intermediate meterDisplay costs in cents2 BytesCRT
90Channel C: Intermediate meterDisplay costs in euro4 BytesCRT
90Channel C: Intermediate meterDisplay costs in euro2 BytesCRT
91Channel C: Intermediate meterMeter reading for day4 Bytes13.10 active energy (Wh)CRT
91Channel C: Intermediate meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
92Channel C: Intermediate meterMeter reading for night4 Bytes13.10 active energy (Wh)CRT
92Channel C: Intermediate meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
93Channel C: Intermediate meterReset1 Bit1.3 enableCW
94Channel C: Main meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
95Channel C: Main meterDisplay costs in cents4 BytesCRT
95Channel C: Main meterDisplay costs in cents2 BytesCRT
95Channel C: Main meterDisplay costs in euro4 BytesCRT
95Channel C: Main meterDisplay costs in euro2 BytesCRT
96Channel C: Main meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
97Channel C: Main meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
98Channel C: Main meterReset1 Bit1.3 enableCW
99Channel C: CounterEvent A1 Bit1.10 start/stopCT
100Channel C: CounterEvent B1 Bit1.10 start/stopCT
101Channel C: Operating hours counterResponse operating hours2 Bytes7.7 time (h)CRT
101Channel C: Operating hours counterTime to the next service2 Bytes7.7 time (h)CRT
102Channel C: Operating hours counterReset operating hours1 Bit1.1 switchCW
102Channel C: Operating hours counterReset service1 Bit1.1 switchCW
103Channel C: Operating hours counterService required1 Bit1.1 switchCT
104Dummy 1041 Bit
105Channel C: Operating hours counterResponse operating hours4 Bytes13.100 time lag (s)CRT
105Channel C: Operating hours counterTime to the next service4 Bytes13.100 time lag (s)CRT
106Dummy 1064 Bytes
107Dummy 1074 Bytes
108Channel DSwitch On/Off1 Bit1.1 switchCW
109Channel DStaircase1 Bit1.1 switchCW
110Channel DLock1 Bit1.3 enableCW
111Channel DScene1 Byte17.1 scene numberCW
112Channel DState1 Bit1.11 stateCRT
113Channel DLogic 11 Bit1.2 booleanCW
114Channel DLogic 21 Bit1.2 booleanCW
115Channel D: Active power meterActive power4 Bytes14.56 power (W)CRT
115Channel D: Active power meterActive power2 Bytes9.24 power (kW)CRT
116Channel D: Active power meterCurrent value2 Bytes7.12 current (mA)CRT
116Channel D: Active power meterCurrent value2 Bytes9.21 current (mA)CRT
116Channel D: Active power meterCurrent value4 Bytes14.19 electric current (A)CRT
117Channel D: Active power meterVoltage value4 Bytes14.27 electric potential (V)CRT
118Channel D: Advanced power measurementApparent power4 Bytes14.56 power (W)CRT
118Channel D: Advanced power measurementApparent power2 Bytes9.24 power (kW)CRT
118Channel D: Advanced power measurementReactive power4 Bytes14.56 power (W)CRT
118Channel D: Advanced power measurementReactive power2 Bytes9.24 power (kW)CRT
118Channel D: Advanced power measurementPower factor cos phi4 Bytes14.57 power factor (cos Φ)CRT
119Channel D: Active power meterExceeding of load1 Bit1.11 stateCRT
120Channel D: Active power meterFalling below of load1 Bit1.11 stateCRT
121Channel D: Active power meterExceedance of current1 Bit1.11 stateCRT
122Channel D: Active power meterLower deviation of current1 Bit1.11 stateCRT
123Channel D: Active power meterExceedance of voltage1 Bit1.11 stateCRT
124Channel D: Active power meterLower deviation of voltage1 Bit1.11 stateCRT
125Channel D: Intermediate meterActive energy (Wh)4 Bytes13.10 active energy (Wh)CRT
125Channel D: Intermediate meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
126Channel D: Intermediate meterDisplay costs in cents4 BytesCRT
126Channel D: Intermediate meterDisplay costs in cents2 BytesCRT
126Channel D: Intermediate meterDisplay costs in euro4 BytesCRT
126Channel D: Intermediate meterDisplay costs in euro2 BytesCRT
127Channel D: Intermediate meterMeter reading for day4 Bytes13.10 active energy (Wh)CRT
127Channel D: Intermediate meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
128Channel D: Intermediate meterMeter reading for night4 Bytes13.10 active energy (Wh)CRT
128Channel D: Intermediate meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
129Channel D: Intermediate meterReset1 Bit1.3 enableCW
130Channel D: Main meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
131Channel D: Main meterDisplay costs in cents4 BytesCRT
131Channel D: Main meterDisplay costs in cents2 BytesCRT
131Channel D: Main meterDisplay costs in euro4 BytesCRT
131Channel D: Main meterDisplay costs in euro2 BytesCRT
132Channel D: Main meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
133Channel D: Main meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
134Channel D: Main meterReset1 Bit1.3 enableCW
135Channel D: CounterEvent A1 Bit1.10 start/stopCT
136Channel D: CounterEvent B1 Bit1.10 start/stopCT
137Channel D: Operating hours counterResponse operating hours2 Bytes7.7 time (h)CRT
137Channel D: Operating hours counterTime to the next service2 Bytes7.7 time (h)CRT
138Channel D: Operating hours counterReset operating hours1 Bit1.1 switchCW
138Channel D: Operating hours counterReset service1 Bit1.1 switchCW
139Channel D: Operating hours counterService required1 Bit1.1 switchCT
140Dummy 1401 Bit
141Channel D: Operating hours counterResponse operating hours4 Bytes13.100 time lag (s)CRT
141Channel D: Operating hours counterTime to the next service4 Bytes13.100 time lag (s)CRT
142Dummy 1424 Bytes
143Dummy 1434 Bytes
144Channel ESwitch On/Off1 Bit1.1 switchCW
145Channel EStaircase1 Bit1.1 switchCW
146Channel ELock1 Bit1.3 enableCW
147Channel EScene1 Byte17.1 scene numberCW
148Channel EState1 Bit1.11 stateCRT
149Channel ELogic 11 Bit1.2 booleanCW
150Channel ELogic 21 Bit1.2 booleanCW
151Channel E: Active power meterActive power4 Bytes14.56 power (W)CRT
151Channel E: Active power meterActive power2 Bytes9.24 power (kW)CRT
152Channel E: Active power meterCurrent value2 Bytes7.12 current (mA)CRT
152Channel E: Active power meterCurrent value2 Bytes9.21 current (mA)CRT
152Channel E: Active power meterCurrent value4 Bytes14.19 electric current (A)CRT
153Channel E: Active power meterVoltage value4 Bytes14.27 electric potential (V)CRT
154Channel E: Advanced power measurementApparent power4 Bytes14.56 power (W)CRT
154Channel E: Advanced power measurementApparent power2 Bytes9.24 power (kW)CRT
154Channel E: Advanced power measurementReactive power4 Bytes14.56 power (W)CRT
154Channel E: Advanced power measurementReactive power2 Bytes9.24 power (kW)CRT
154Channel E: Advanced power measurementPower factor cos phi4 Bytes14.57 power factor (cos Φ)CRT
155Channel E: Active power meterExceeding of load1 Bit1.11 stateCRT
156Channel E: Active power meterFalling below of load1 Bit1.11 stateCRT
157Channel E: Active power meterExceedance of current1 Bit1.11 stateCRT
158Channel E: Active power meterLower deviation of current1 Bit1.11 stateCRT
159Channel E: Active power meterExceedance of voltage1 Bit1.11 stateCRT
160Channel E: Active power meterLower deviation of voltage1 Bit1.11 stateCRT
161Channel E: Intermediate meterActive energy (Wh)4 Bytes13.10 active energy (Wh)CRT
161Channel E: Intermediate meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
162Channel E: Intermediate meterDisplay costs in cents4 BytesCRT
162Channel E: Intermediate meterDisplay costs in cents2 BytesCRT
162Channel E: Intermediate meterDisplay costs in euro4 BytesCRT
162Channel E: Intermediate meterDisplay costs in euro2 BytesCRT
163Channel E: Intermediate meterMeter reading for day4 Bytes13.10 active energy (Wh)CRT
163Channel E: Intermediate meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
164Channel E: Intermediate meterMeter reading for night4 Bytes13.10 active energy (Wh)CRT
164Channel E: Intermediate meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
165Channel E: Intermediate meterReset1 Bit1.3 enableCW
166Channel E: Main meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
167Channel E: Main meterDisplay costs in cents4 BytesCRT
167Channel E: Main meterDisplay costs in cents2 BytesCRT
167Channel E: Main meterDisplay costs in euro4 BytesCRT
167Channel E: Main meterDisplay costs in euro2 BytesCRT
168Channel E: Main meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
169Channel E: Main meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
170Channel E: Main meterReset1 Bit1.3 enableCW
171Channel E: CounterEvent A1 Bit1.10 start/stopCT
172Channel E: CounterEvent B1 Bit1.10 start/stopCT
173Channel E: Operating hours counterResponse operating hours2 Bytes7.7 time (h)CRT
173Channel E: Operating hours counterTime to the next service2 Bytes7.7 time (h)CRT
174Channel E: Operating hours counterReset operating hours1 Bit1.1 switchCW
174Channel E: Operating hours counterReset service1 Bit1.1 switchCW
175Channel E: Operating hours counterService required1 Bit1.1 switchCT
176Dummy 1761 Bit
177Channel E: Operating hours counterResponse operating hours4 Bytes13.100 time lag (s)CRT
177Channel E: Operating hours counterTime to the next service4 Bytes13.100 time lag (s)CRT
178Dummy 1784 Bytes
179Dummy 1794 Bytes
180Channel FSwitch On/Off1 Bit1.1 switchCW
181Channel FStaircase1 Bit1.1 switchCW
182Channel FLock1 Bit1.3 enableCW
183Channel FScene1 Byte17.1 scene numberCW
184Channel FState1 Bit1.11 stateCRT
185Channel FLogic 11 Bit1.2 booleanCW
186Channel FLogic 21 Bit1.2 booleanCW
187Channel F: Active power meterActive power4 Bytes14.56 power (W)CRT
187Channel F: Active power meterActive power2 Bytes9.24 power (kW)CRT
188Channel F: Active power meterCurrent value2 Bytes7.12 current (mA)CRT
188Channel F: Active power meterCurrent value2 Bytes9.21 current (mA)CRT
188Channel F: Active power meterCurrent value4 Bytes14.19 electric current (A)CRT
189Channel F: Active power meterVoltage value4 Bytes14.27 electric potential (V)CRT
190Channel F: Advanced power measurementApparent power4 Bytes14.56 power (W)CRT
190Channel F: Advanced power measurementApparent power2 Bytes9.24 power (kW)CRT
190Channel F: Advanced power measurementReactive power4 Bytes14.56 power (W)CRT
190Channel F: Advanced power measurementReactive power2 Bytes9.24 power (kW)CRT
190Channel F: Advanced power measurementPower factor cos phi4 Bytes14.57 power factor (cos Φ)CRT
191Channel F: Active power meterExceeding of load1 Bit1.11 stateCRT
192Channel F: Active power meterFalling below of load1 Bit1.11 stateCRT
193Channel F: Active power meterExceedance of current1 Bit1.11 stateCRT
194Channel F: Active power meterLower deviation of current1 Bit1.11 stateCRT
195Channel F: Active power meterExceedance of voltage1 Bit1.11 stateCRT
196Channel F: Active power meterLower deviation of voltage1 Bit1.11 stateCRT
197Channel F: Intermediate meterActive energy (Wh)4 Bytes13.10 active energy (Wh)CRT
197Channel F: Intermediate meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
198Channel F: Intermediate meterDisplay costs in cents4 BytesCRT
198Channel F: Intermediate meterDisplay costs in cents2 BytesCRT
198Channel F: Intermediate meterDisplay costs in euro4 BytesCRT
198Channel F: Intermediate meterDisplay costs in euro2 BytesCRT
199Channel F: Intermediate meterMeter reading for day4 Bytes13.10 active energy (Wh)CRT
199Channel F: Intermediate meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
200Channel F: Intermediate meterMeter reading for night4 Bytes13.10 active energy (Wh)CRT
200Channel F: Intermediate meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
201Channel F: Intermediate meterReset1 Bit1.3 enableCW
202Channel F: Main meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
203Channel F: Main meterDisplay costs in cents4 BytesCRT
203Channel F: Main meterDisplay costs in cents2 BytesCRT
203Channel F: Main meterDisplay costs in euro4 BytesCRT
203Channel F: Main meterDisplay costs in euro2 BytesCRT
204Channel F: Main meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
205Channel F: Main meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
206Channel F: Main meterReset1 Bit1.3 enableCW
207Channel F: CounterEvent A1 Bit1.10 start/stopCT
208Channel F: CounterEvent B1 Bit1.10 start/stopCT
209Channel F: Operating hours counterResponse operating hours2 Bytes7.7 time (h)CRT
209Channel F: Operating hours counterTime to the next service2 Bytes7.7 time (h)CRT
210Channel F: Operating hours counterReset operating hours1 Bit1.1 switchCW
210Channel F: Operating hours counterReset service1 Bit1.1 switchCW
211Channel F: Operating hours counterService required1 Bit1.1 switchCT
212Dummy 2121 Bit
213Channel F: Operating hours counterResponse operating hours4 Bytes13.100 time lag (s)CRT
213Channel F: Operating hours counterTime to the next service4 Bytes13.100 time lag (s)CRT
214Dummy 2144 Bytes
215Dummy 2154 Bytes
216Central functionSwitch1 Bit1.1 switchCRW
217Central functionLock hand operation1 Bit1.3 enableCW
218Total active powerTotal value4 Bytes14.56 power (W)CRT
218Total active powerTotal value2 Bytes9.24 power (kW)CRT
219Total currentTotal value2 Bytes7.12 current (mA)CRT
219Total currentTotal value2 Bytes9.21 current (mA)CRT
219Total currentTotal value4 Bytes14.19 electric current (A)CRT
220Total advanced power measurementApparent power4 Bytes14.56 power (W)CRT
220Total advanced power measurementApparent power2 Bytes9.24 power (kW)CRT
220Total advanced power measurementApparent power4 Bytes14.57 power factor (cos Φ)CRT
221Total active powerExceeding of load1 Bit1.11 stateCRT
222Total active powerFalling below of load1 Bit1.11 stateCRT
223Total currentExceedance of current1 Bit1.11 stateCRT
224Total currentLower deviation of current1 Bit1.11 stateCRT
225Total intermediate meterActive energy (kWh)4 Bytes13.10 active energy (Wh)CRT
225Total intermediate meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
226Total intermediate meterDisplay costs in cents2 BytesCRT
226Total intermediate meterDisplay costs in cents4 BytesCRT
226Total intermediate meterDisplay costs in euro4 BytesCRT
226Total intermediate meterDisplay costs in euro2 BytesCRT
227Total intermediate meterMeter reading for day4 Bytes13.10 active energy (Wh)CRT
227Total intermediate meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
228Total intermediate meterMeter reading for night4 Bytes13.10 active energy (Wh)CRT
228Total intermediate meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
229Total intermediate meterReset1 Bit1.3 enableCW
230Total main meterActive energy (kWh)4 Bytes13.13 active energy (kWh)CRT
231Total main meterDisplay costs in cents4 BytesCRT
231Total main meterDisplay costs in cents2 BytesCRT
231Total main meterDisplay costs in euro4 BytesCRT
231Total main meterDisplay costs in euro2 BytesCRT
232Total main meterMeter reading for night4 Bytes13.13 active energy (kWh)CRT
233Total main meterMeter reading for day4 Bytes13.13 active energy (kWh)CRT
234Total main meterReset1 Bit1.3 enableCW
235Total counterEvent A1 Bit1.10 start/stopCT
236Total counterEvent B1 Bit1.10 start/stopCT
237Electricity price for dayEnter the electricity tariff in cents4 BytesCW
237Electricity price for dayEnter the electricity tariff in cents2 BytesCW
237Electricity price for dayEnter electricity tariff in euro4 BytesCW
237Electricity price for dayEnter electricity tariff in euro2 BytesCW
238Electricity price for nightEnter the electricity tariff in cents4 BytesCW
238Electricity price for nightEnter the electricity tariff in cents2 BytesCW
238Electricity price for nightEnter electricity tariff in euro4 BytesCW
238Electricity price for nightEnter electricity tariff in euro2 BytesCW
239Current elecricity priceDisplay electricity tariff in cent4 BytesCRT
239Current elecricity priceDisplay electricity tariff in cent2 BytesCRT
239Current elecricity priceDisplay electricity tariff in euro4 BytesCRT
239Current elecricity priceDisplay electricity tariff in euro2 BytesCRT
240Central functionOperating1 Bit1.11 stateCRT
241Central functionDay/Night1 Bit1.2 booleanCW
242Central functionSlave time3 Bytes10.1 time of dayCW
243Central functionVoltage error1 Bit1.5 alarmCT
244Central functionGroup State4 Bytes27.1 bit-combined info on/offCRT
245Central functionExternal active power4 Bytes14.56 power (W)CW
245Central functionExternal active power2 Bytes9.24 power (kW)CW
246Dummy 2464 Bytes
247Dummy 2474 Bytes
Parameters (144)
ParameterTypeDefault
###unsignedInt 1…2552
Channel AlistSwitch
Time for staircaseunsignedInt 0…300000
Modelistnormaly opend
Prewarning timeunsignedInt 0…300000
Prewarninglistnot active
Manual switching offlistnot active
Warning timeunsignedInt 0…300001
Verlängern bei TreppenlichtlistDisable
On delayunsignedInt 0…300000
Extend staircase timelistnot active
Off delayunsignedInt 0…300000
Zyklisches senden dess aktuellen IstwertesunsignedInt 0…300000
Save scenelistdisabled
State for recalling after receiving Szene numberlistOff
Behaviour when lockedlistno change
Behaviour when unlockedlistno change
invertieren des Lock Objekteslistnot inverted
Behaviour at bus power uplistno change
Bus Power Up Message Delaylist1 s
Logical functionslistnot active
active Logic Inputslistnot active
Logic operationslistOR
Scenelistnot active
logic OperationslistOR
Scene AlistOff
Scene number Alistnot used
Scene BlistOff
Scene number Blistnot used
Scene ClistOff
Scene number Clistnot used
Scene DlistOff
Scene number Dlistnot used
Scene ElistOff
Scene number Elistnot used
Scene FlistOff
Scene number Flistnot used
Scene GlistOff
Scene number Glistnot used
Scene HlistOff
Scene number Hlistnot used
Send value cycliclistno send
Send cycliclistno send
Send meter reading cycliclistno send
Send meter reading cycliclist5 min
Value for exceeding of load [0…4600]unsignedInt 0…4600100
Value for falling below of load [1…4600]unsignedInt 1…46005
Value for exceeding of current [3…20000]unsignedInt 3…20000100
Value for falling below of current [3…20000]unsignedInt 3…20000300
Value for exceeding of voltage [180…300]unsignedInt 180…300240
Value for falling below of voltage V [180…300]unsignedInt 180…300210
Enable active power measurementlistYes
Object settinglist4Byte floating value in W (DPT 14.056)
Send value at changelistno send
HysteresisunsignedInt 10…10010
Behavior at exceedinglistsend nothing
Behavior at not exceedinglistsend nothing
Behavior when not falling belowlistsend nothing
Send actual count at changeslistnot active
Behavior when falling belowlistsend nothing
Object settinglistValue in mA (DPT 7.012)
Enable current measurementlistYes
Monitoring exceeding of loadlistnot active
Monitoring falling below of loadlistnot active
Monitoring exceeding of currentlistnot active
Monitoring falling below of currentlistnot active
Enable voltage measurementlistYes
Monitoring exceeding of voltagelistnot active
Monitoring falling below of voltagelistnot active
Enable main and Intermediate meterlistNo
Object settinglistValue in Wh (DPT 13.010)
Behavior after programminglistno reset
Retention time by exceedingunsignedInt 0…300000
Retention time by falling belowunsignedInt 0…300000
Enable advanced power outputlistNo
Object settinglistApparent power in VA (DPT 14.056)
Send actual cost cycliclistno send
Send actual count all …list10
Send meter reading every …list10
Send actual count all …unsignedInt 1…6553510
Send actual coast all …unsignedInt 1…25510
Send actual cost at changeslistnot active
Send actual coast all …unsignedInt 1…255100
Enable operating hours counterlistNo
Type of operating hours counterlistIncrementer
Count at activatedlistCurrent
Start counter iflistRelais ON
Report of operating hours every ...unsignedInt 0…1000
Report of service hours every …unsignedInt 0…1000
Service interval at intervals ofunsignedInt 0…650000
Add the channel to total current measurementlistNo
Hand controllistactive
Activate Event A withlistnot active
Final valueunsignedInt 1…4294967295200
HoursunsignedInt 0…230
MinutesunsignedInt 0…590
Daylistevery day
With object "Event A"listsend OFF-telegram
All values of intermediate meterlistno send
All values of main meterlistno send
Costs of intermediate meterlistno send
Costs of main meterlistno send
Reset of intermediate meterlistnot active
Reset of main meterlistnot active
Activate Event B withlistnot active
With object "Event B"listsend OFF-telegram
Cost calculated overlistone constant value (day)
Electricity tariff for dayfloat 0…100.22
Electricity tariff for nightfloat 0…100.18
DPT objects "Electricity price for day" and "Current electricity price"list4Byte floating value [Cent]
DPT objects "Electricity price for day/night" and "Current electricity price"list4Byte floating value [Cent]
DPT for costs at intermediate and main meterlist4Byte floating value [Cent]
Control change Day<->Night overlistDay/Night-object (Day=1, Night=0)
Time in hours to switching from Day to NightunsignedInt 0…230
Time in hours to switching from Day to NightunsignedInt 0…590
Time in hours to switching from Night to DayunsignedInt 0…590
Time in hours to switching from Night to DayunsignedInt 0…230
Enable total active powerlistYes
Value for exceeding of load [0…27600]unsignedInt 0…27600100
Behavior at not exceedinglistsend OFF-telegram
Value for falling below of load [0…27600]unsignedInt 0…276005
Erweiterte Leistungsausgabe aktivierenlistNo
Enable total currentlistYes
Enable total energy meter and cost counterlistNo
Send cyclic object "Operating"list10 min
Send group statuslistno send
Channel BlistSwitch
Report of operating hours every …unsignedInt 0…1000
Value for falling below of voltage [180…300]unsignedInt 180…300210
Channel ClistSwitch
Central switchinglistnot active
Startup timeoutunsignedInt 0…1001
Add the channel to total voltage monitoringlistNo
DPT for object "Current electricity price"list4Byte floating value [Cent]
Channel DlistSwitch
Channel ElistSwitch
Channel FlistSwitch
Value for exceeding of currentlist3-60000 mA
Set value [3…60000]unsignedInt 3…60000100
Set valuelist70 A
Value for falling below of currentlist3-60000 mA
Set value [3...60000]unsignedInt 3…60000100
Object selectionlist2Byte (DPT 7.007 in hours)
Behaviour at bus power downlistno change

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switching, Staircase, Active power measurement 6f 1.2 latest$0011C9502026-11-25174 KBDownload

About this file

This is the official ETS product database for the MDT technologies GmbH AZI-0616.01 Actuator 6-fold with active power measurement (AZI-0616.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from MDT technologies GmbH

All MDT technologies GmbH products