MDT technologies GmbH AMI-0416.03 AMI-0416.03 Switch Actuator with current measurement 4-fold, 4SU MDRC, 16/20A

AMI-0416.03 Switch Actuator with current measurement 4-fold, 4SU MDRC, 16/20A AMI-0416.03

MDT technologies GmbH · Order number AMI-0416.03 · Actuators › Switch Actuators with current measurment

Download .knxprod Switch, Staircase light, Current measurement, 4-channel 3.1 · 192 KB

Product

ManufacturerMDT technologies GmbH
Product nameAMI-0416.03 Switch Actuator with current measurement 4-fold, 4SU MDRC, 16/20A
Order numberAMI-0416.03
HardwareSchaltaktor mit Strommesung 4-fach
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)72
RegistrationCertified · 2023-04-13
Languagesde-DE, en-US, es-ES, fr-FR, it-IT
Catalog entryM-0083_H-354-3_HP-0319-31-587B_CI-AMI.2D0416.2E03-1
Fingerprint587B
SHA-25626363dade02584452a1064d45c95e88eec642739a4ee8eb30829e718dbe4c3ed
First seen2026-11-25
Markets69 markets

Application program: Switch, Staircase light, Current measurement, 4-channel 3.1

Application number$0319
Version3.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters426
Group objects57
Group objects (57)
NoNameFunctionSizeDPTFlags
0Channel {{ChNo}}: {{0}}Switch1 Bit1.1 switchCW
1Channel {{ChNo}}: {{0}}Service required1 Bit1.5 alarmCRT
1Channel {{ChNo}}: {{0}}Staircase light1 Bit1.1 switchCW
1Channel {{ChNo}}: {{0}}Switch pulse1 Bit1.1 switchCW
2Channel {{ChNo}}: {{0}}Meter reading: Operating hours4 Bytes13.100 time lag (s)CRT
2Channel {{ChNo}}: {{0}}Meter reading: Operating hours2 Bytes7.7 time (h)CRT
2Channel {{ChNo}}: {{0}}Time until next service4 Bytes13.100 time lag (s)CRT
2Channel {{ChNo}}: {{0}}Time until next service2 Bytes7.7 time (h)CRT
2Channel {{ChNo}}: {{0}}Staircase light with time1 Byte5.5 ratio (0..255)CW
3Channel {{ChNo}}: {{0}}Reset: Operating hours1 Bit1.1 switchCW
3Channel {{ChNo}}: {{0}}Reset: Service message1 Bit1.1 switchCW
3Channel {{ChNo}}: {{0}}Prewarning1 Bit1.1 switchCT
4Channel {{ChNo}}: {{0}}Lock1 Bit1.3 enableCW
5Channel {{ChNo}}: {{0}}Forced guidance2 Bit2.1 switch controlCW
5Channel {{ChNo}}: {{0}}Priority1 Bit1.1 switchCW
6Channel {{ChNo}}: {{0}}Scene1 Byte17.1 scene numberCW
6Channel {{ChNo}}: {{0}}Scene1 Byte18.1 scene controlCW
7Channel {{ChNo}}: {{0}}Status1 Bit1.11 stateCRT
8Channel {{ChNo}}: {{0}}Inverted status1 Bit1.11 stateCRT
9Channel {{ChNo}}: {{0}}Logic 11 Bit1.2 booleanCW
10Channel {{ChNo}}: {{0}}Logic 21 Bit1.2 booleanCW
11Channel {{ChNo}}: {{0}}Threshold switch1 Byte5.1 percentage (0..100%)CW
11Channel {{ChNo}}: {{0}}Threshold switch1 Byte5.5 ratio (0..255)CW
11Channel {{ChNo}}: {{0}}Threshold switch2 Bytes7.1 pulsesCW
11Channel {{ChNo}}: {{0}}Threshold switch2 Bytes9.1 temperature (°C)CW
11Channel {{ChNo}}: {{0}}Threshold switch2 Bytes9.4 lux (Lux)CW
12Channel {{ChNo}}: {{0}}Current value2 Bytes7.12 current (mA)CRT
12Channel {{ChNo}}: {{0}}Current value2 Bytes9.21 current (mA)CRT
12Channel {{ChNo}}: {{0}}Current value4 Bytes14.19 electric current (A)CRT
12Channel {{ChNo}}: {{0}}Power value2 Bytes9.24 power (kW)CRT
12Channel {{ChNo}}: {{0}}Power value4 Bytes14.56 power (W)CRT
13Channel {{ChNo}}: {{0}}Current exceedance 11 Bit1.1 switchCRT
13Channel {{ChNo}}: {{0}}Current exceedance 11 Byte17.1 scene numberCRT
14Channel {{ChNo}}: {{0}}Current exceedance 21 Bit1.1 switchCRT
14Channel {{ChNo}}: {{0}}Current exceedance 21 Byte17.1 scene numberCRT
15Channel {{ChNo}}: {{0}}Current undercut1 Bit1.1 switchCRT
15Channel {{ChNo}}: {{0}}Current undercut1 Byte17.1 scene numberCRT
16Channel {{ChNo}}: {{0}}Load failure1 Bit1.5 alarmCRT
16Channel {{ChNo}}: {{0}}Residual current1 Bit1.5 alarmCRT
16Channel {{ChNo}}: {{0}}Residual current / Load failure1 Bit1.5 alarmCRT
17Channel {{ChNo}}: {{0}}Reset: Meter1 Bit1.10 start/stopCW
18Channel {{ChNo}}: {{0}}Meter: Power (Wh)4 Bytes13.10 active energy (Wh)CRWT
18Channel {{ChNo}}: {{0}}Meter: Power (kWh)4 Bytes13.13 active energy (kWh)CRWT
80Central functionSwitch1 Bit1.1 switchCW
81Central functionLock manual operation1 Bit1.3 enableCW
82Central functionIn operation1 Bit1.11 stateCRT
83CO_dummy1 Bit
84Total currentCurrent value2 Bytes9.21 current (mA)CRT
84Total currentCurrent value4 Bytes14.19 electric current (A)CRT
84Total currentValue of total power2 Bytes9.24 power (kW)CRT
84Total currentValue of total power4 Bytes14.56 power (W)CRT
85Total currentExceedance: Switch1 Bit1.1 switchCRT
85Total currentExceedance: Send scene1 Byte17.1 scene numberCRT
86Total currentMeter: Total power (Wh)4 Bytes13.10 active energy (Wh)CRT
86Total currentMeter: Total power (kWh)4 Bytes13.13 active energy (kWh)CRT
87CO_dummy1 Bit
88CO_dummy1 Bit
Parameters (145)
ParameterTypeDefault
Startup timeunsignedInt 2…2402
Channel Alistswitch
Economy mode, switch off LEDs afterlistnot active
Send "In operation" cyclicallylistnot active
Manual operationlistactive
Channel Blistswitch
Channel Clistswitch
Channel Dlistswitch
Set all current meters to "0" after transmitting the applicationlistnot active
Total current / Total current meterlistnot active
Consumption meter in the channel writable via objectlistnot active
Object selectionlist2 Byte floating value in mA (DPT 9.021)
Factor for conversion to theoretical power (kW): Current value x FactorunsignedInt 100…250230
Factor for conversion to theoretical power (W): Current value x FactorunsignedInt 100…250230
Send value on change of ...listnot active
Send cyclically every …list1 h
Monitoring of current exceedancelistnot active
Send output cyclically every …listnot active
Total current meter function (Wh/kWh) (theoretical value, sum of the activated current meters per channel)listnot active
Object selectionlist4 Byte value in Wh (DPT 13.010)
Send cyclically every …listnot active
Minimum changelistnot active
Send value if exceededlistvalue "1"
Send scene if exceededlist1
Send value on withdrawallistvalue "0"
Send scene on withdrawallist2
Value for exceedancefloat 1…6020
Value rangelist100 mA - 1000 mA
Value for exceedanceunsignedInt 100…10001000
Value range for withdrawallist100 mA - 1000 mA
Value for withdrawalunsignedInt 100…1000100
Value for withdrawalfloat 1…6010
Description of channel/objectstext
Additional texttext
Modelistnormally open
Switch-on delayunsignedInt 0…300000
Switch-off delayunsignedInt 0…300000
Central functionlistactive
Send statusliston change
Send status cyclically (0 = not active)unsignedInt 0…300000
Additional inverted statuslistnot active
Behaviour on lockinglistno change
Behaviour on unlockinglistno change
Priority / Forced guidancelistnot active
Fallback time for forced guidance ( 0 = not active)unsignedInt 0…6000
Behaviour after forced guidancelistno change
Fallback time for priority (0 = not active)unsignedInt 0…6000
Behavior after deactivation of prioritylistno change
Behaviour on bus power returnlistno change
Behaviour on bus power failurelistno change
Logiclistnot active
Sceneslistnot active
Threshold switchlistnot active
Operating hours meterlistnot active
Logic operationlistOR
Logic functionlistwith switch object and one logic object
Invert inputslistnot active
Invert outputlistdo not invert
Set objects to value after bus power returnlistnot active
Value for object "Switch"listnot active
Value for object "Logic 1"listnot active
Value for object "Logic 2"listnot active
Learn scenelistnot active
Scene Alistnot active
Scene numberlist1
Scene behaviourlistON
Scene Blistnot active
Scene numberlist2
Scene Clistnot active
Scene numberlist3
Scene Dlistnot active
Scene numberlist4
Scene Elistnot active
Scene numberlist5
Scene Flistnot active
Scene numberlist6
Scene Glistnot active
Scene numberlist7
Scene Hlistnot active
Scene numberlist8
Datapoint typelist1 Byte DPT 5.001 Percent (0…100 %)
Behaviour when undercutlistnot active
Lower thresholdlist0 %
Behaviour when exceededlistnot active
Upper thresholdlist90 %
Set valuelist50 %
Lower thresholdunsignedInt 0…2550
Upper thresholdunsignedInt 0…2550
Set valueunsignedInt 1…25510
Lower thresholdunsignedInt 0…655000
Upper thresholdunsignedInt 0…655000
Set valueunsignedInt 1…65500100
Lower thresholdfloat -100…20010
Upper thresholdfloat -100…20030
Set valuefloat -100…20020
Lower thresholdfloat 0…100000100
Upper thresholdfloat 0…10000060000
Set valuefloat 0…100000400
Type of meterlistoperating hours meter
Datapoint typelist4 Byte value in s (DPT 13.100)
Send operating hours every ... (0 = not active)unsignedInt 0…100000
Send operating hours cyclically every …listnot active
Send "Time until next service" every ... (0 = not active)unsignedInt 0…100000
Send service message at intervals of ...unsignedInt 0…600000
Meter: Consumption (theoretical value)listnot active
Send meter reading cyclically every ...listnot active
Object selectionlist2 Byte value in mA (DPT 7.012)
Add channel to total currentlistactive
Monitoring of current exceedance 1listnot active
Value rangelist10 mA - 1000 mA
Value for exceedanceunsignedInt 10…100010
Delaytime0
Switch off channellistnot active
Error messagelistnot active
Thresholdlist20 mA
Current measurementlistnot active
Value for exceedancefloat 1…201
Condition during delaylistValue must remain above "Value for exceedance" after exceeding
Value range for withdrawallist10 mA - 1000 mA
Value for withdrawalunsignedInt 10…100010
Value for withdrawalfloat 1…201
Monitoring of current exceedance 2listnot active
Monitoring of current undercutlistnot active
Value for undercutunsignedInt 10…100010
Value for undercutfloat 1…201
Condition during delaylistValue must remain below "Value for undercut" after undercutting
Send value if undercutlistvalue "1"
Send scene if undercutlist1
Additional switch objectlistnot active
Staircase light timerunsignedInt 1…300001
Prewarninglistnot active
Prewarning durationunsignedInt 0…300001
Prewarning timeunsignedInt 0…300000
Manual switch-offlistactive
Extend staircase light timerlistrestart time
Factor for object "Staircase light with time"list1 s
Behaviour on unlockinglistOFF
Behaviour after forced guidancelistOFF
Behavior after deactivation of prioritylistOFF
Behaviour on bus power returnliststate before bus power failure
Send meter reading cyclically every …listnot active
Pulse timelist500 ms
Repeat pulse oncelistnot active
Time until the next pulselist0,5 s
Current meter (theoretical value)listnot active

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch, Staircase light, Current measurement, 4-channel 3.1 latest$0319587B2026-11-25192 KBDownload

About this file

This is the official ETS product database for the MDT technologies GmbH AMI-0416.03 Switch Actuator with current measurement 4-fold, 4SU MDRC, 16/20A (AMI-0416.03), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from MDT technologies GmbH

All MDT technologies GmbH products