KNX Database
MDT technologies GmbH AKH-0400.03 AKH-0400.03 Heating Actuator 4-fold, 2SU MDRC, 24/230VAC

AKH-0400.03 Heating Actuator 4-fold, 2SU MDRC, 24/230VAC AKH-0400.03

MDT technologies GmbH · Order number AKH-0400.03 · Actuators › Heating actuators

Control valves, Control, 24/230VAC

Download .knxprod Heating actuator 4-fold 3.4 · 205 KB

Product

ManufacturerMDT technologies GmbH
Product nameAKH-0400.03 Heating Actuator 4-fold, 2SU MDRC, 24/230VAC
Order numberAKH-0400.03
HardwareHeizungsaktor 4-fach
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)36
RegistrationRegistered · 2021-05-31
Languagesde-DE, en-US, es-ES, fr-FR, it-IT
Catalog entryM-0083_H-359-1_HP-013B-34-09EC_CI-AKH.2D0400.2E03-1
Fingerprint09EC
SHA-256f2b037d4cf261f6432055e071376543c2df8104a8c299f900dee644e10ddf9ed
First seen2026-11-25
Markets69 markets

Application program: Heating actuator 4-fold 3.4

Application number$013B
Version3.4
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters350
Group objects279
Group objects (279)
NoNameFunctionSizeDPTFlags
1Channel A: {{0}}Receive temperature value2 Bytes9.1 temperature (°C)CWTU
1Channel A: {{0}}Input control value1 Bit1.1 switchCWTU
1Channel A: {{0}}Input control value1 Byte5.1 percentage (0..100%)CWTU
1Channel B: {{0}}Receive temperature value2 Bytes9.1 temperature (°C)CWTU
1Channel B: {{0}}Input control value1 Bit1.1 switchCWTU
1Channel B: {{0}}Input control value1 Byte5.1 percentage (0..100%)CWTU
1Channel C: {{0}}Receive temperature value2 Bytes9.1 temperature (°C)CWTU
1Channel C: {{0}}Input control value1 Bit1.1 switchCWTU
1Channel C: {{0}}Input control value1 Byte5.1 percentage (0..100%)CWTU
1Channel D: {{0}}Receive temperature value2 Bytes9.1 temperature (°C)CWTU
1Channel D: {{0}}Input control value1 Bit1.1 switchCWTU
1Channel D: {{0}}Input control value1 Byte5.1 percentage (0..100%)CWTU
2Channel A: {{0}}Preset setpoint2 Bytes9.1 temperature (°C)CW
2Channel B: {{0}}Preset setpoint2 Bytes9.1 temperature (°C)CW
2Channel C: {{0}}Preset setpoint2 Bytes9.1 temperature (°C)CW
2Channel D: {{0}}Preset setpoint2 Bytes9.1 temperature (°C)CW
3Channel A: {{0}}Preset Comfort setpoint2 Bytes9.1 temperature (°C)CW
3Channel A: {{0}}Combi object: Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
3Channel A: {{0}}Preset (Basic) Comfort setpoint2 Bytes9.1 temperature (°C)CW
3Channel A: {{0}}Combi object (Heating): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
3Channel B: {{0}}Preset Comfort setpoint2 Bytes9.1 temperature (°C)CW
3Channel B: {{0}}Combi object: Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
3Channel B: {{0}}Preset (Basic) Comfort setpoint2 Bytes9.1 temperature (°C)CW
3Channel B: {{0}}Combi object (Heating): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
3Channel C: {{0}}Preset Comfort setpoint2 Bytes9.1 temperature (°C)CW
3Channel C: {{0}}Combi object: Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
3Channel C: {{0}}Preset (Basic) Comfort setpoint2 Bytes9.1 temperature (°C)CW
3Channel C: {{0}}Combi object (Heating): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
3Channel D: {{0}}Preset Comfort setpoint2 Bytes9.1 temperature (°C)CW
3Channel D: {{0}}Combi object: Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
3Channel D: {{0}}Preset (Basic) Comfort setpoint2 Bytes9.1 temperature (°C)CW
3Channel D: {{0}}Combi object (Heating): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
4Channel A: {{0}}Preset Standby setpoint2 Bytes9.1 temperature (°C)CW
4Channel B: {{0}}Preset Standby setpoint2 Bytes9.1 temperature (°C)CW
4Channel C: {{0}}Preset Standby setpoint2 Bytes9.1 temperature (°C)CW
4Channel D: {{0}}Preset Standby setpoint2 Bytes9.1 temperature (°C)CW
5Channel A: {{0}}Preset Night setpoint2 Bytes9.1 temperature (°C)CW
5Channel B: {{0}}Preset Night setpoint2 Bytes9.1 temperature (°C)CW
5Channel C: {{0}}Preset Night setpoint2 Bytes9.1 temperature (°C)CW
5Channel D: {{0}}Preset Night setpoint2 Bytes9.1 temperature (°C)CW
6Channel A: {{0}}Preset Frost protection setpoint2 Bytes9.1 temperature (°C)CW
6Channel A: {{0}}Preset Heat protection setpoint2 Bytes9.1 temperature (°C)CW
6Channel B: {{0}}Preset Frost protection setpoint2 Bytes9.1 temperature (°C)CW
6Channel B: {{0}}Preset Heat protection setpoint2 Bytes9.1 temperature (°C)CW
6Channel C: {{0}}Preset Frost protection setpoint2 Bytes9.1 temperature (°C)CW
6Channel C: {{0}}Preset Heat protection setpoint2 Bytes9.1 temperature (°C)CW
6Channel D: {{0}}Preset Frost protection setpoint2 Bytes9.1 temperature (°C)CW
6Channel D: {{0}}Preset Heat protection setpoint2 Bytes9.1 temperature (°C)CW
7Channel A: {{0}}Combi object (Cooling): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
7Channel B: {{0}}Combi object (Cooling): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
7Channel C: {{0}}Combi object (Cooling): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
7Channel D: {{0}}Combi object (Cooling): Preset setpoint8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
8Channel A: {{0}}Send current setpoint2 Bytes9.1 temperature (°C)CRT
8Channel B: {{0}}Send current setpoint2 Bytes9.1 temperature (°C)CRT
8Channel C: {{0}}Send current setpoint2 Bytes9.1 temperature (°C)CRT
8Channel D: {{0}}Send current setpoint2 Bytes9.1 temperature (°C)CRT
9Channel A: {{0}}Manual setpoint shift (2byte)2 Bytes9.2 temperature difference (K)CW
9Channel B: {{0}}Manual setpoint shift (2byte)2 Bytes9.2 temperature difference (K)CW
9Channel C: {{0}}Manual setpoint shift (2byte)2 Bytes9.2 temperature difference (K)CW
9Channel D: {{0}}Manual setpoint shift (2byte)2 Bytes9.2 temperature difference (K)CW
10Channel A: {{0}}Manual setpoint shift (1=+ / 0=-)1 Bit1.7 stepCW
10Channel A: {{0}}Manual setpoint shift (1byte)1 Byte6.10 counter pulses (-128..127)CW
10Channel B: {{0}}Manual setpoint shift (1=+ / 0=-)1 Bit1.7 stepCW
10Channel B: {{0}}Manual setpoint shift (1byte)1 Byte6.10 counter pulses (-128..127)CW
10Channel C: {{0}}Manual setpoint shift (1=+ / 0=-)1 Bit1.7 stepCW
10Channel C: {{0}}Manual setpoint shift (1byte)1 Byte6.10 counter pulses (-128..127)CW
10Channel D: {{0}}Manual setpoint shift (1=+ / 0=-)1 Bit1.7 stepCW
10Channel D: {{0}}Manual setpoint shift (1byte)1 Byte6.10 counter pulses (-128..127)CW
11Channel A: {{0}}Send status of setpoint shift2 Bytes9.2 temperature difference (K)CRT
11Channel B: {{0}}Send status of setpoint shift2 Bytes9.2 temperature difference (K)CRT
11Channel C: {{0}}Send status of setpoint shift2 Bytes9.2 temperature difference (K)CRT
11Channel D: {{0}}Send status of setpoint shift2 Bytes9.2 temperature difference (K)CRT
12Channel A: {{0}}Control value Heating: Send status1 Byte5.1 percentage (0..100%)CRT
12Channel A: {{0}}Control value: Send status1 Byte5.1 percentage (0..100%)CRT
12Channel B: {{0}}Control value Heating: Send status1 Byte5.1 percentage (0..100%)CRT
12Channel B: {{0}}Control value: Send status1 Byte5.1 percentage (0..100%)CRT
12Channel C: {{0}}Control value Heating: Send status1 Byte5.1 percentage (0..100%)CRT
12Channel C: {{0}}Control value: Send status1 Byte5.1 percentage (0..100%)CRT
12Channel D: {{0}}Control value Heating: Send status1 Byte5.1 percentage (0..100%)CRT
12Channel D: {{0}}Control value: Send status1 Byte5.1 percentage (0..100%)CRT
13Channel A: {{0}}Control value Cooling: Send status1 Byte5.1 percentage (0..100%)CRT
13Channel B: {{0}}Control value Cooling: Send status1 Byte5.1 percentage (0..100%)CRT
13Channel C: {{0}}Control value Cooling: Send status1 Byte5.1 percentage (0..100%)CRT
13Channel D: {{0}}Control value Cooling: Send status1 Byte5.1 percentage (0..100%)CRT
14Channel A: {{0}}Control value > 0%: send status1 Bit1.11 stateCRT
14Channel A: {{0}}Control value Cooling is active > 0%: send status (from R6.2/R5.2)1 Bit1.11 stateCRT
14Channel B: {{0}}Control value > 0%: send status1 Bit1.11 stateCRT
14Channel B: {{0}}Control value Cooling is active > 0%: send status (from R6.2/R5.2)1 Bit1.11 stateCRT
14Channel C: {{0}}Control value > 0%: send status1 Bit1.11 stateCRT
14Channel C: {{0}}Control value Cooling is active > 0%: send status (from R6.2/R5.2)1 Bit1.11 stateCRT
14Channel D: {{0}}Control value > 0%: send status1 Bit1.11 stateCRT
14Channel D: {{0}}Control value Cooling is active > 0%: send status (from R6.2/R5.2)1 Bit1.11 stateCRT
15Channel A: {{0}}Send valve status1 Bit1.11 stateCRT
15Channel A: {{0}}Send valve status Heating: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel A: {{0}}Send valve status: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel A: {{0}}Send valve status Cooling: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel B: {{0}}Send valve status Heating: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel B: {{0}}Send valve status: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel B: {{0}}Send valve status Cooling: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel C: {{0}}Send valve status Heating: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel C: {{0}}Send valve status: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel C: {{0}}Send valve status Cooling: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel D: {{0}}Send valve status Heating: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel D: {{0}}Send valve status: 1=open, 0=closed1 Bit1.11 stateCRT
15Channel D: {{0}}Send valve status Cooling: 1=open, 0=closed1 Bit1.11 stateCRT
16Channel A: {{0}}Additional stage: Send control value Heating1 Bit1.1 switchCRT
16Channel B: {{0}}Additional stage: Send control value Heating1 Bit1.1 switchCRT
16Channel C: {{0}}Additional stage: Send control value Heating1 Bit1.1 switchCRT
16Channel D: {{0}}Additional stage: Send control value Heating1 Bit1.1 switchCRT
17Channel A: {{0}}Mode selection1 Byte20.102 HVAC modeCW
17Channel B: {{0}}Mode selection1 Byte20.102 HVAC modeCW
17Channel C: {{0}}Mode selection1 Byte20.102 HVAC modeCW
17Channel D: {{0}}Mode selection1 Byte20.102 HVAC modeCW
18Channel A: {{0}}Comfort operating mode: Comfort extension1 Bit1.10 start/stopCW
18Channel B: {{0}}Comfort operating mode: Comfort extension1 Bit1.10 start/stopCW
18Channel C: {{0}}Comfort operating mode: Comfort extension1 Bit1.10 start/stopCW
18Channel D: {{0}}Comfort operating mode: Comfort extension1 Bit1.10 start/stopCW
19Channel A: {{0}}Switch Comfort operating mode1 Bit1.1 switchCW
19Channel B: {{0}}Switch Comfort operating mode1 Bit1.1 switchCW
19Channel C: {{0}}Switch Comfort operating mode1 Bit1.1 switchCW
19Channel D: {{0}}Switch Comfort operating mode1 Bit1.1 switchCW
20Channel A: {{0}}Switch Night operating mode1 Bit1.1 switchCW
20Channel B: {{0}}Switch Night operating mode1 Bit1.1 switchCW
20Channel C: {{0}}Switch Night operating mode1 Bit1.1 switchCW
20Channel D: {{0}}Switch Night operating mode1 Bit1.1 switchCW
21Channel A: {{0}}Switch Frost protection operating mode1 Bit1.1 switchCW
21Channel A: {{0}}Switch Heat protection operating mode1 Bit1.1 switchCW
21Channel A: {{0}}Switch Frost/Heat protection operating mode1 Bit1.1 switchCW
21Channel B: {{0}}Switch Frost protection operating mode1 Bit1.1 switchCW
21Channel B: {{0}}Switch Heat protection operating mode1 Bit1.1 switchCW
21Channel B: {{0}}Switch Frost/Heat protection operating mode1 Bit1.1 switchCW
21Channel C: {{0}}Switch Frost protection operating mode1 Bit1.1 switchCW
21Channel C: {{0}}Switch Heat protection operating mode1 Bit1.1 switchCW
21Channel C: {{0}}Switch Frost/Heat protection operating mode1 Bit1.1 switchCW
21Channel D: {{0}}Switch Frost protection operating mode1 Bit1.1 switchCW
21Channel D: {{0}}Switch Heat protection operating mode1 Bit1.1 switchCW
21Channel D: {{0}}Switch Frost/Heat protection operating mode1 Bit1.1 switchCW
22Channel A: {{0}}DPT_HVAC Status: Send controller status1 ByteCRT
22Channel A: {{0}}DPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
22Channel B: {{0}}DPT_HVAC Status: Send controller status1 ByteCRT
22Channel B: {{0}}DPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
22Channel C: {{0}}DPT_HVAC Status: Send controller status1 ByteCRT
22Channel C: {{0}}DPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
22Channel D: {{0}}DPT_HVAC Status: Send controller status1 ByteCRT
22Channel D: {{0}}DPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
23Channel A: {{0}}DPT_HVAC Status: Send controller status1 ByteCRT
23Channel A: {{0}}DPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
23Channel A: {{0}}RHCC Status: Send controller status2 Bytes22.101 RHCC statusCRT
23Channel A: {{0}}DPT_RTSM combined status: Send controller status1 Byte21.107 combined status RTSMCRT
23Channel A: {{0}}DPT_RTC combined status: Send controller status2 Bytes22.103 combined status RTCCRT
23Channel B: {{0}}DPT_HVAC Status: Send controller status1 ByteCRT
23Channel B: {{0}}DPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
23Channel B: {{0}}RHCC Status: Send controller status2 Bytes22.101 RHCC statusCRT
23Channel B: {{0}}DPT_RTSM combined status: Send controller status1 Byte21.107 combined status RTSMCRT
23Channel B: {{0}}DPT_RTC combined status: Send controller status2 Bytes22.103 combined status RTCCRT
23Channel C: {{0}}DPT_HVAC Status: Send controller status1 ByteCRT
23Channel C: {{0}}DPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
23Channel C: {{0}}RHCC Status: Send controller status2 Bytes22.101 RHCC statusCRT
23Channel C: {{0}}DPT_RTSM combined status: Send controller status1 Byte21.107 combined status RTSMCRT
23Channel C: {{0}}DPT_RTC combined status: Send controller status2 Bytes22.103 combined status RTCCRT
23Channel D: {{0}}DPT_HVAC Status: Send controller status1 ByteCRT
23Channel D: {{0}}DPT_HVAC Mode: Send controller status1 Byte20.102 HVAC modeCRT
23Channel D: {{0}}RHCC Status: Send controller status2 Bytes22.101 RHCC statusCRT
23Channel D: {{0}}DPT_RTSM combined status: Send controller status1 Byte21.107 combined status RTSMCRT
23Channel D: {{0}}DPT_RTC combined status: Send controller status2 Bytes22.103 combined status RTCCRT
24Channel A: {{0}}Send Frost alarm1 Bit1.5 alarmCRT
24Channel B: {{0}}Send Frost alarm1 Bit1.5 alarmCRT
24Channel C: {{0}}Send Frost alarm1 Bit1.5 alarmCRT
24Channel D: {{0}}Send Frost alarm1 Bit1.5 alarmCRT
25Channel A: {{0}}Send Heat alarm1 Bit1.5 alarmCRT
25Channel B: {{0}}Send Heat alarm1 Bit1.5 alarmCRT
25Channel C: {{0}}Send Heat alarm1 Bit1.5 alarmCRT
25Channel D: {{0}}Send Heat alarm1 Bit1.5 alarmCRT
26Channel A: {{0}}Receive flow temperature Heating2 Bytes9.1 temperature (°C)CWT
26Channel B: {{0}}Receive flow temperature Heating2 Bytes9.1 temperature (°C)CWT
26Channel C: {{0}}Receive flow temperature Heating2 Bytes9.1 temperature (°C)CWT
26Channel D: {{0}}Receive flow temperature Heating2 Bytes9.1 temperature (°C)CWT
27Channel A: {{0}}Receive surface temperature Cooling2 Bytes9.1 temperature (°C)CWT
27Channel B: {{0}}Receive surface temperature Cooling2 Bytes9.1 temperature (°C)CWT
27Channel C: {{0}}Receive surface temperature Cooling2 Bytes9.1 temperature (°C)CWT
27Channel D: {{0}}Receive surface temperature Cooling2 Bytes9.1 temperature (°C)CWT
28Channel A: {{0}}Diagnosis status14 Bytes16.1 Character String (ISO 8859-1)CRT
28Channel B: {{0}}Diagnosis status14 Bytes16.1 Character String (ISO 8859-1)CRT
28Channel C: {{0}}Diagnosis status14 Bytes16.1 Character String (ISO 8859-1)CRT
28Channel D: {{0}}Diagnosis status14 Bytes16.1 Character String (ISO 8859-1)CRT
29Channel A: {{0}}Window contact: 0=closed / 1=open1 Bit1.19 window/doorCWTU
29Channel A: {{0}}Window contact: 1=closed / 0=open1 Bit1.2 booleanCWTU
29Channel B: {{0}}Window contact: 0=closed / 1=open1 Bit1.19 window/doorCWTU
29Channel B: {{0}}Window contact: 1=closed / 0=open1 Bit1.2 booleanCWTU
29Channel C: {{0}}Window contact: 0=closed / 1=open1 Bit1.19 window/doorCWTU
29Channel C: {{0}}Window contact: 1=closed / 0=open1 Bit1.2 booleanCWTU
29Channel D: {{0}}Window contact: 0=closed / 1=open1 Bit1.19 window/doorCWTU
29Channel D: {{0}}Window contact: 1=closed / 0=open1 Bit1.2 booleanCWTU
30Channel A: {{0}}Lock object Heating: Lock control value1 Bit1.3 enableCRWTU
30Channel A: {{0}}Enable object Heating: Enable control value1 Bit1.3 enableCRWTU
30Channel B: {{0}}Lock object Heating: Lock control value1 Bit1.3 enableCRWTU
30Channel B: {{0}}Enable object Heating: Enable control value1 Bit1.3 enableCRWTU
30Channel C: {{0}}Lock object Heating: Lock control value1 Bit1.3 enableCRWTU
30Channel C: {{0}}Enable object Heating: Enable control value1 Bit1.3 enableCRWTU
30Channel D: {{0}}Lock object Heating: Lock control value1 Bit1.3 enableCRWTU
30Channel D: {{0}}Enable object Heating: Enable control value1 Bit1.3 enableCRWTU
31Channel A: {{0}}Lock object Cooling: Lock control value1 Bit1.3 enableCRWTU
31Channel A: {{0}}Enable object Cooling: Enable control value1 Bit1.3 enableCRWTU
31Channel B: {{0}}Lock object Cooling: Lock control value1 Bit1.3 enableCRWTU
31Channel B: {{0}}Enable object Cooling: Enable control value1 Bit1.3 enableCRWTU
31Channel C: {{0}}Lock object Cooling: Lock control value1 Bit1.3 enableCRWTU
31Channel C: {{0}}Enable object Cooling: Enable control value1 Bit1.3 enableCRWTU
31Channel D: {{0}}Lock object Cooling: Lock control value1 Bit1.3 enableCRWTU
31Channel D: {{0}}Enable object Cooling: Enable control value1 Bit1.3 enableCRWTU
32Channel A: {{0}}Forced position1 Bit1.5 alarmCW
32Channel A: {{0}}Dew point alarm1 Bit1.5 alarmCW
32Channel B: {{0}}Forced position1 Bit1.5 alarmCW
32Channel B: {{0}}Dew point alarm1 Bit1.5 alarmCW
32Channel C: {{0}}Forced position1 Bit1.5 alarmCW
32Channel C: {{0}}Dew point alarm1 Bit1.5 alarmCW
32Channel D: {{0}}Forced position1 Bit1.5 alarmCW
32Channel D: {{0}}Dew point alarm1 Bit1.5 alarmCW
33Channel A: {{0}}Override: Minimum control value1 Byte5.1 percentage (0..100%)CW
33Channel B: {{0}}Override: Minimum control value1 Byte5.1 percentage (0..100%)CW
33Channel C: {{0}}Override: Minimum control value1 Byte5.1 percentage (0..100%)CW
33Channel D: {{0}}Override: Minimum control value1 Byte5.1 percentage (0..100%)CW
34Channel A: {{0}}Override: Maximum control value1 Byte5.1 percentage (0..100%)CW
34Channel B: {{0}}Override: Maximum control value1 Byte5.1 percentage (0..100%)CW
34Channel C: {{0}}Override: Maximum control value1 Byte5.1 percentage (0..100%)CW
34Channel D: {{0}}Override: Maximum control value1 Byte5.1 percentage (0..100%)CW
35Channel A: {{0}}Fault in case of mains failure / short circuit / control value error1 Bit1.5 alarmCRT
35Channel B: {{0}}Fault in case of mains failure / short circuit / control value error1 Bit1.5 alarmCRT
35Channel C: {{0}}Fault in case of mains failure / short circuit / control value error1 Bit1.5 alarmCRT
35Channel D: {{0}}Fault in case of mains failure / short circuit / control value error1 Bit1.5 alarmCRT
36Channel A: {{0}}Reference value in percent1 Byte5.1 percentage (0..100%)CW
36Channel A: {{0}}Reference value in Lux2 Bytes9.4 lux (Lux)CW
36Channel B: {{0}}Reference value in percent1 Byte5.1 percentage (0..100%)CW
36Channel B: {{0}}Reference value in Lux2 Bytes9.4 lux (Lux)CW
36Channel C: {{0}}Reference value in percent1 Byte5.1 percentage (0..100%)CW
36Channel C: {{0}}Reference value in Lux2 Bytes9.4 lux (Lux)CW
36Channel D: {{0}}Reference value in percent1 Byte5.1 percentage (0..100%)CW
36Channel D: {{0}}Reference value in Lux2 Bytes9.4 lux (Lux)CW
37Channel A: {{0}}Status Reference value1 Bit1.11 stateCRT
37Channel B: {{0}}Status Reference value1 Bit1.11 stateCRT
37Channel C: {{0}}Status Reference value1 Bit1.11 stateCRT
37Channel D: {{0}}Status Reference value1 Bit1.11 stateCRT
38Channel A: {{0}}Lock Reference value1 Bit1.3 enableCW
38Channel B: {{0}}Lock Reference value1 Bit1.3 enableCW
38Channel C: {{0}}Lock Reference value1 Bit1.3 enableCW
38Channel D: {{0}}Lock Reference value1 Bit1.3 enableCW
54Channel B: {{0}}Control value > 0%: send status1 Bit1.11 stateCRT
55Channel B: {{0}}Send valve status1 Bit1.11 stateCRT
94Channel C: {{0}}Control value > 0%: send status1 Bit1.11 stateCRT
95Channel C: {{0}}Send valve status1 Bit1.11 stateCRT
134Channel D: {{0}}Control value > 0%: send status1 Bit1.11 stateCRT
135Channel D: {{0}}Send valve status1 Bit1.11 stateCRT
161Summer = 1 / Winter = 0Switchover1 Bit1.1 switchCWTU
161Summer = 0 / Winter = 1Switchover1 Bit1.1 switchCWTU
161Summer = 1 / Winter = 0Summer/Winter override for 7 days1 Bit1.1 switchCWTU
161Summer = 0 / Winter = 1Summer/Winter override for 7 days1 Bit1.1 switchCWTU
162Summer = 1 / Winter = 0Status1 Bit1.1 switchCRT
162Summer = 0 / Winter = 1Status1 Bit1.1 switchCRT
163Heating = 1 / Cooling = 0Switchover1 Bit1.100 cooling/heatingCWTU
164Heating = 1 / Cooling = 0Status1 Bit1.100 cooling/heatingCRT
165Heating requirement0 if all valves closed, else 11 Bit1.2 booleanCRT
165Heating/Cooling requirement0 if all valves closed, else 11 Bit1.2 booleanCRT
165Heating requirement0 if control value = 0%, else 11 Bit1.2 booleanCRT
165Heating/Cooling requirement0 if control value = 0%, else 11 Bit1.2 booleanCRT
166Cooling requirement0 if all valves closed, else 11 Bit1.2 booleanCRT
166Cooling requirement0 if control value = 0%, else 11 Bit1.2 booleanCRT
167FaultIn case of short circuit1 Bit1.5 alarmCRT
167FaultAt power failure/short circuit1 Bit1.5 alarmCRT
168Maximum control valueOutput1 Byte5.1 percentage (0..100%)CRT
168Maximum control value (Heating)Output1 Byte5.1 percentage (0..100%)CRT
169Maximum control valueInput1 Byte5.1 percentage (0..100%)CW
169Maximum control value (Heating)Input1 Byte5.1 percentage (0..100%)CW
170Maximum control value (Cooling)Output1 Byte5.1 percentage (0..100%)CRT
171Maximum control value (Cooling)Input1 Byte5.1 percentage (0..100%)CW
172SceneActivate1 Byte17.1 scene numberCW
173Central functionOperating1 Bit1.11 stateCRT
174Outside temperature / Reference valueReceive measured value2 Bytes9.1 temperature (°C)CWTU
175TimeReceive current value3 Bytes10.1 time of dayCWTU
176DateReceive current value3 Bytes11.1 dateCWTU
177Time / DateReceive current value8 Bytes19.1 date timeCWTU
Parameters (190)
ParameterTypeDefault
Startup timeunsignedInt 2…2402
Send "Operation" cyclicallylistnot active
Thermal drivelist230VAC
Sticking protection (valve open/closed for 5 minutes every 6 days)listactive
Selection: Heating systemlist2-pipe / 1 circuit (Heating or Cooling)
Selection: Operating modelistHeating
Switchover for Heating/Coolinglistvia object Summer / Winter
Set control value „Heating“ to 0% during “Summer” modelistactive
Reference channel for automatic switchover Heating/Cooling (2 pipe system)listChannel A
Object for requirement Heating/Coolinglistnot active
Heating/Cooling requirement depending onlistcontrol value
Polarity for object "Summer/Winter"listSummer = 1 / Winter = 0
Object maximum control valuelistnot active
Request control/temperature valueslistactive
Summer/Winterlistrestore state
Heating/Coolinglistrestore state
Language for diagnosis textlistGerman
Send status object Heating/Cooling cyclicallylistnot active
Determination of Summer/Winterlistvia object
Object maximum control value Heatinglistnot active
Object maximum control value Coolinglistnot active
Setpoint Frost protection for all channelsfloat 3…177
Setpoint Heat protection for all channelsfloat 24…4035
Valve typelistnormally closed
Operating mode of electrical outputlistHeating
Object valve statuslistvalve status (1=open, 0=closed)
Scene Alistnot active
Scene Blistnot active
Scene Clistnot active
Scene Dlistnot active
Scene Elistnot active
Scene Flistnot active
Scene Glistnot active
Scene Hlistnot active
Scene Ilistnot active
Scene Jlistnot active
Scene Klistnot active
Scene Llistnot active
Scene Mlistnot active
Scene Nlistnot active
Scene Olistnot active
Scene Plistnot active
Scene numberlist1
Operating modelistno change
Setpoint settinglistno change
Scene valid for channel Alistnot active
Scene valid for channel Blistnot active
Scene valid for channel Clistnot active
Scene valid for channel Dlistnot active
Scene numberlist2
Scene numberlist3
Scene numberlist4
Scene numberlist5
Scene numberlist6
Scene numberlist7
Scene numberlist8
Scene numberlist9
Scene numberlist10
Scene numberlist11
Scene numberlist12
Scene numberlist13
Scene numberlist14
Scene numberlist15
Scene numberlist16
Temperature threshold Winter -> SummerunsignedInt 10…2516
Reaction speedlistmedium
Channel Alistnot active
Channel Blistnot active
Channel Clistnot active
Channel Dlistnot active
Set control value „Cooling“ to 0% during “Winter” modelistactive
Description of channel/objectstext
Additional texttext
Vault detectionlistactive
Controller typelistintegrated controller
Operating modelistHeating
Independent systemlistnot active
Systemlist4-pipe / 2 circuit (Heating and Cooling separately)
Heating systemlistUnderfloor Heating (4K / 150min)
Proportional rangelist4 K
Reset timelist150 min
Additional stagelistnot active
Direction of action with rising temperaturelistObject sends 1 when Heating
Control valuelist2-step control (switching)
Distancelist2,0 K
Cooling systemlistCooling ceiling (4K / 150min)
PrioritylistFrost(Heat) protection/Comfort/Night/Standby
Setpoints for Standby/Nightlistindependent setpoints
(Basic) Comfort setpointfloat 7…3521
Setpoint Standbyfloat 7…3519
Setpoint Nightfloat 7…3518
Standby reductionlist2,0 K
Night reductionlist3,0 K
Setting of setpoint "Frost protection"listglobal
Setpoint Frost protectionfloat 3…177
Separate objects for setpoints Comfort/Standby/Night/Frost protectionlistnot active
Maximum setpoint shiftfloat 0…105
Setpoint shift via 1Bit/1Byte objectlist1 bit
Step widthlist0,5 K
Status setpoint shiftlistnot active
Setpoint shift applies tolistComfort
Action when shifting in Night/Standbylistno action
Delete setpoint shift after change of modelistnot active
Delete setpoint shift after new absolute setpointlistactive
Reset setpoints to parameterization after operating mode changelistnot active
Reset (Basic) Comfort setpoint to configured value after change of modelistnot active
Delete setpoint shift after new (Basic) Comfort setpointlistactive
Send setpoint changelistactive
Send current setpoint cyclicallylistnot active
Comfort extension with timelistnot active
Comfort extension timelist30 min
Operating mode after resetlistComfort with parameterized setpoint
Operating mode after reprogramminglistComfort
HVAC Status objectlistHVAC Mode (DPT 20.102)
Additional HVAC Status objectlistnot active
Send HVAC Status object cyclicallylistnot active
(Basic) Comfort setpointfloat 7…3523
Setpoint Standbyfloat 7…3524
Setpoint Nightfloat 7…3525
Standby increaselist2,0 K
Night increaselist3,0 K
Setting of setpoint "Heat protection"listglobal
Setpoint Heat protectionfloat 24…4035
Separate objects for setpoints of Comfort/Standby/Night Heating protectionlistnot active
Reference variable minimumunsignedInt 10…6028
Dead zone between Heating and Coolinglist0 K
Separate objects for setpoints Comfort/Standby/Night/Frost protection/Heating protectionlistnot active
Alarmslistnot active
Frost alarm if value lessunsignedInt 3…107
Heat alarm if value greaterunsignedInt 25…4035
Window contactlistnot active
State of windowlist0=closed / 1=open (standard DPT)
Delay timeunsignedInt 0…2405
Action when opening the windowlistforce Frost/Heat protection
Action when closing the windowlistHVAC Modus before locking
Release timelist12 h
Send valve status cyclicallylist5 min
Forced positionlistnot active
Control value for forced positionlist50%
Consider channel in Heating/Cooling requirement and maximum control valuelistnot active
Forced position/Dew point alarmlistnot active
Control value for forced positionlist0%
PWM cycle timelist10 min
Minimum limitation of control value during Heatinglist0%
Maximum limitation of control value during Heatinglist100%
Minimum limitation of control valuelist0%
Maximum limitation of control valuelist100%
Limitation via objectlistnot active
Control value when falling below the minimum limitationlist0% = 0%, otherwise use minimum set value
Send status of control value cyclicallylist5 min
Object valve status Heatinglist1, if control value > 0%
Additional sensor for flow temperaturelistnot active
Additional sensor for cooling mediumlistnot active
Minimum limitation of control value during Coolinglist0%
Send control value for Heating and Cooling cyclicallylist5 min
Send control value cyclicallylist5 min
Control value for forced position Heatinglist50%
Control value for forced position Coolinglist0%
Maximum flow temperature HeatingunsignedInt 0…6040
Minimum limit of flow temperaturelistnot active
Minimum flow temperature HeatingunsignedInt 0…6020
Enabled for Comfortlistactive
Enabled for Standbylistnot active
Enabled for Nightlistnot active
Enabled for Frost/Heat protectionlistnot active
Minimum temperature of cooling mediumunsignedInt 0…6010
Emergency modelistactive
Emergency mode on failure of control value after…time30
Control value for emergency modelist50%
Lock object for control value Heatinglistnot active
Lock object for control value Coolinglistnot active
Emergency mode on failure of temperature value after…time30
Control value for emergency mode Heatinglist50%
Control value for emergency mode Coolinglist50%
Send diagnosis textlistnot active
Control valuelistcontinuous PI control
Switching hysteresislist0,5 K
Maximum limitation of control value during Coolinglist100%
Object valve statuslist1, if control value > 0%
Reference controllistnot active
Reference variable maximumunsignedInt 10…6038
Setpoint change at maximum reference variablefloat -5…5-2
Current setpoint value taken into Reference controllistnot active
Reference variable minimumlist0%
Reference variable maximumlist100%
Reference variable minimumlist30000 Lux
Reference variable maximumlist80000 Lux
Release Reference control fromunsignedInt 5…3515
Threshold outdoor temperaturelistnot active
Setpoint change at maximum reference variablefloat 1…1010

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Heating actuator 4-fold 3.4 latest$013B09EC2026-11-25205 KBDownload

About this file

This is the official ETS product database for the MDT technologies GmbH AKH-0400.03 Heating Actuator 4-fold, 2SU MDRC, 24/230VAC (AKH-0400.03), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from MDT technologies GmbH

All MDT technologies GmbH products