KNX Database

L&J secure dimmer switch 4fold DIM4FX-SEC

Lingg & Janke · Order number DIM4FX-SEC · lighting › L&J secure series

Download .knxprod SEC 4x dimming, scenes, sequences 3013-30 3.0 · 136 KB

Product

ManufacturerLingg & Janke
Product nameL&J secure dimmer switch 4fold
Order numberDIM4FX-SEC
Product textL&J secure dimmer switch 4f
HardwareDIM4FX-SEC
MediumTwisted Pair
Bus current (mA)6
Rail mountedYes
Width (mm)72
RegistrationRegistered · 2021-04-28
Languagesen-US, de-DE
Catalog entryM-00E1_H-3013.2D10-1_HP-3013-30-88A7_CI-DIM4FX.2DSEC-1
Fingerprint88A7
SHA-256b30a70c693a6e64a3322c69a21ab09017594985666e73340db7fb5273c833830
First seen2026-11-25
Markets69 markets

Application program: SEC 4x dimming, scenes, sequences 3013-30 3.0

Application number$3013
Version3.0
Mask versionMV-0021 (2.1)
KNX Data SecureYes
Minimum ETS version5.0
Parameters424
Group objects36
Group objects (36)
NoNameFunctionSizeDPTFlags
0input A switchingchannel A object 11 Bit1.1 switchCW
1input A dimmingchannel A object 24 Bit3.7 dimming controlCW
2input A valuechannel A object 31 Byte5.1 percentage (0..100%)CW
3output A switching statuschannel A object 41 Bit1.1 switchCT
4output A value statuschannel A object 51 Byte5.1 percentage (0..100%)CT
5input A inhibitchannel A object 61 Bit1.1 switchCW
6input A sceneschannel A object 71 Byte18.1 scene controlCW
7input A sequence 1channel A object 81 Bit1.1 switchCW
8input A sequence 2channel A object 91 Bit1.1 switchCW
19input B switchingchannel B object 11 Bit1.1 switchCW
20input B dimmingchannel B object 24 Bit3.7 dimming controlCW
21input B valuechannel B object 31 Byte5.1 percentage (0..100%)CW
22output B switching statuschannel B object 41 Bit1.1 switchCT
23output B value statuschannel B object 51 Byte5.1 percentage (0..100%)CT
24input B inhibitchannel B object 61 Bit1.1 switchCW
25input B sceneschannel B object 71 Byte18.1 scene controlCW
26input B sequence 1channel B object 81 Bit1.1 switchCW
27input B sequence 2channel B object 91 Bit1.1 switchCW
38input C switchingchannel C object 11 Bit1.1 switchCW
39input C dimmingchannel C object 24 Bit3.7 dimming controlCW
40input C valuechannel C object 31 Byte5.1 percentage (0..100%)CW
41output C switching statuschannel C object 41 Bit1.1 switchCT
42output C value statuschannel C object 51 Byte5.1 percentage (0..100%)CT
43input C inhibitchannel C object 61 Bit1.1 switchCW
44input C sceneschannel C object 71 Byte18.1 scene controlCW
45input C sequence 1channel C object 81 Bit1.1 switchCW
46input C sequence 2channel C object 91 Bit1.1 switchCW
57input D switchingchannel D object 11 Bit1.1 switchCW
58input D dimmingchannel D object 24 Bit3.7 dimming controlCW
59input D valuechannel D object 31 Byte5.1 percentage (0..100%)CW
60output D switching statuschannel D object 41 Bit1.1 switchCT
61output D value statuschannel D object 51 Byte5.1 percentage (0..100%)CT
62input D inhibitchannel D object 61 Bit1.1 switchCW
63input D sceneschannel D object 71 Byte18.1 scene controlCW
64input D sequence 1channel D object 81 Bit1.1 switchCW
65input D sequence 2channel D object 91 Bit1.1 switchCW
Parameters (82)
ParameterTypeDefault
mode of operationlistchannel A master, channel B master
at bus voltage recoverylistvalue before bus voltage failure
switching functionslistno
timing functionslistno
sceneslistno
sequence 1listno
sequence 2listno
inhibit functionlistno
status messageslistno
value when switching ONlistMAX
ON with dimminglistyes
OFF with dimminglistyes
lower output limitlist30%
upper output limitlist100%
time for dimming (1..14400 s) (0%..100%)unsignedInt 1…144005
value is (also scenes, sequences and inhibit)listset fast
time for soft setting (1..14400 s) (0%..100%)unsignedInt 1…144005
soft ONlistno
time for soft ON (1..14400 s) (0%..100%)unsignedInt 1…144005
soft OFFlistno
time for soft OFF (1..14400 s) (100%..0%)unsignedInt 1…144005
time delay / blinkinglistnone
time for ON delay (0..3600 s)unsignedInt 0…36000
time for OFF delay (0..3600 s)unsignedInt 0…36000
time for staircase function (1..3600 s)unsignedInt 1…3600180
blinking ON time (1..3600 s)unsignedInt 1…3600180
blinking OFF time (1..3600 s)unsignedInt 1…36006
scene 1listno action
scene 2listno action
scene 3listno action
scene 4listno action
scene 5listno action
scene 6listno action
scene 7listno action
scene 8listno action
scene 9listno action
scene 10listno action
scene 11listno action
scene 12listno action
scene 13listno action
scene 14listno action
scene 15listno action
scene 16listno action
scene 17listno action
scene 18listno action
scene 19listno action
scene 20listno action
scene 21listno action
scene 22listno action
scene 23listno action
scene 24listno action
scene 25listno action
scene 26listno action
scene 27listno action
scene 28listno action
scene 29listno action
scene 30listno action
scene 31listno action
scene 32listno action
enable scene savinglistno
1st action of sequence 1listMAX
time between 1st and 2nd action (0..64800 s)unsignedInt 0…648000
2nd action of sequence 1listno action
time between 2nd and 3rd action (0..64800 s)unsignedInt 0…648000
3rd action of sequence 1listno action
time between 3rd and 4th action (0..64800 s)unsignedInt 0…648000
4th action of sequence 1listno action
action when object value = 0listOFF
1st action of sequence 2listMAX
time between 1st and 2nd action (0..64800 s)unsignedInt 0…6480010
2nd action of sequence 2list30%
time between 2nd and 3rd action (0..64800 s)unsignedInt 0…648001
3rd action of sequence 2listMAX
time between 3rd and 4th action (0..64800 s)unsignedInt 0…648003
4th action of sequence 2listOFF
inhibit withlist1 (ON)
at bus voltage recovery set inhibit object tolist0 (OFF)
value when inhibit startslistno action
value when inhibit endslistno action
switching statuslistdo not transmit
value statuslistdo not transmit
mode of operationlistchannel C master, channel D master

Version history

ApplicationApp noFingerprintFirst seenSizeFile
SEC 4x dimming, scenes, sequences 3013-30 3.0 latest$301388A72026-11-25136 KBDownload

About this file

This is the official ETS product database for the Lingg & Janke L&J secure dimmer switch 4fold (DIM4FX-SEC), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Lingg & Janke

All Lingg & Janke products