dimmer switch 2 4fold 570W universal hand DIM4FU-2-FW
Lingg & Janke · Order number DIM4FU-2-FW · lighting › eibDUO series
Download .knxprod 4x dimming-FW, meters, scenes, sequences 3003-22 2.2 · 100 KB
Product
| Manufacturer | Lingg & Janke |
|---|---|
| Product name | dimmer switch 2 4fold 570W universal hand |
| Order number | DIM4FU-2-FW |
| Product text | eibDuo dimmer switch 2 4f 570W universal hand |
| Hardware | DIM4FU-2-FW |
| Medium | Twisted Pair |
| Bus current (mA) | 6 |
| Rail mounted | Yes |
| Width (mm) | 216 |
| Registration | Registered · 2014-08-26 |
| Languages | en-US, de-DE |
| Catalog entry | M-00E1_H-3003-1_HP-3003-22-7DB8_CI-DIM4FU.2D2.2DFW-1 |
| Fingerprint | 7DB8 |
| SHA-256 | f81470be786bea63054b82841b0e999198d05a167eb6d48ee6fb0796eb0a7e60 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: 4x dimming-FW, meters, scenes, sequences 3003-22 2.2
| Application number | $3003 |
|---|---|
| Version | 2.2 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | No |
| Parameters | 495 |
| Group objects | 76 |
Group objects (76)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | input A switching | channel A object 1 | 1 Bit | 1.1 switch | CW |
| 1 | input A dimming | channel A object 2 | 4 Bit | 3.7 dimming control | CW |
| 2 | input A value | channel A object 3 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 3 | output A switching status | channel A object 4 | 1 Bit | 1.1 switch | CT |
| 4 | output A value status | channel A object 5 | 1 Byte | 5.1 percentage (0..100%) | CT |
| 5 | input A inhibit | channel A object 6 | 1 Bit | 1.1 switch | CW |
| 6 | input A scenes | channel A object 7 | 1 Byte | 17.1 scene number | CW |
| 7 | input A sequence 1 | channel A object 8 | 1 Bit | 1.1 switch | CW |
| 8 | input A sequence 2 | channel A object 9 | 1 Bit | 1.1 switch | CW |
| 9 | output A gen. error | channel A object 10 | 1 Bit | 1.1 switch | CT |
| 10 | output A no mains error | channel A object 11 | 1 Bit | 1.1 switch | CT |
| 11 | output A overload error | channel A object 12 | 1 Bit | 1.1 switch | CT |
| 12 | output A EIS11 meter S/N | channel A object 13 | 4 Bytes | DPT.12 | CT |
| 13 | output A EIS1 meter status | channel A object 14 | 1 Bit | 1.1 switch | CT |
| 14 | output A EIS11 meter reading (kWh) | channel A object 15 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 15 | output A EIS11 meter reading (Wh) | channel A object 16 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 16 | output A EIS9 act. power (W) | channel A object 17 | 4 Bytes | 14.56 power (W) | CT |
| 17 | output A EIS9 voltage (V) | channel A object 18 | 4 Bytes | 14.27 electric potential (V) | CT |
| 18 | output A EIS9 current (A) | channel A object 19 | 4 Bytes | 14.19 electric current (A) | CT |
| 19 | input B switching | channel B object 1 | 1 Bit | 1.1 switch | CW |
| 20 | input B dimming | channel B object 2 | 4 Bit | 3.7 dimming control | CW |
| 21 | input B value | channel B object 3 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 22 | output B switching status | channel B object 4 | 1 Bit | 1.1 switch | CT |
| 23 | output B value status | channel B object 5 | 1 Byte | 5.1 percentage (0..100%) | CT |
| 24 | input B inhibit | channel B object 6 | 1 Bit | 1.1 switch | CW |
| 25 | input B scenes | channel B object 7 | 1 Byte | 17.1 scene number | CW |
| 26 | input B sequence 1 | channel B object 8 | 1 Bit | 1.1 switch | CW |
| 27 | input B sequence 2 | channel B object 9 | 1 Bit | 1.1 switch | CW |
| 28 | output B gen. error | channel B object 10 | 1 Bit | 1.1 switch | CT |
| 29 | output B no mains error | channel B object 11 | 1 Bit | 1.1 switch | CT |
| 30 | output B overload error | channel B object 12 | 1 Bit | 1.1 switch | CT |
| 31 | output B EIS11 meter S/N | channel B object 13 | 4 Bytes | DPT.12 | CT |
| 32 | output B EIS1 meter status | channel B object 14 | 1 Bit | 1.1 switch | CT |
| 33 | output B EIS11 meter reading (kWh) | channel B object 15 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 34 | output B EIS11 meter reading (Wh) | channel B object 16 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 35 | output B EIS9 act. power (W) | channel B object 17 | 4 Bytes | 14.56 power (W) | CT |
| 36 | output B EIS9 voltage (V) | channel B object 18 | 4 Bytes | 14.27 electric potential (V) | CT |
| 37 | output B EIS9 current (A) | channel B object 19 | 4 Bytes | 14.19 electric current (A) | CT |
| 38 | input C switching | channel C object 1 | 1 Bit | 1.1 switch | CW |
| 39 | input C dimming | channel C object 2 | 4 Bit | 3.7 dimming control | CW |
| 40 | input C value | channel C object 3 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 41 | output C switching status | channel C object 4 | 1 Bit | 1.1 switch | CT |
| 42 | output C value status | channel C object 5 | 1 Byte | 5.1 percentage (0..100%) | CT |
| 43 | input C inhibit | channel C object 6 | 1 Bit | 1.1 switch | CW |
| 44 | input C scenes | channel C object 7 | 1 Byte | 17.1 scene number | CW |
| 45 | input C sequence 1 | channel C object 8 | 1 Bit | 1.1 switch | CW |
| 46 | input C sequence 2 | channel C object 9 | 1 Bit | 1.1 switch | CW |
| 47 | output C gen. error | channel C object 10 | 1 Bit | 1.1 switch | CT |
| 48 | output C no mains error | channel C object 11 | 1 Bit | 1.1 switch | CT |
| 49 | output C overload error | channel C object 12 | 1 Bit | 1.1 switch | CT |
| 50 | output C EIS11 meter S/N | channel C object 13 | 4 Bytes | DPT.12 | CT |
| 51 | output C EIS1 meter status | channel C object 14 | 1 Bit | 1.1 switch | CT |
| 52 | output C EIS11 meter reading (kWh) | channel C object 15 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 53 | output C EIS11 meter reading (Wh) | channel C object 16 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 54 | output C EIS9 act. power (W) | channel C object 17 | 4 Bytes | 14.56 power (W) | CT |
| 55 | output C EIS9 voltage (V) | channel C object 18 | 4 Bytes | 14.27 electric potential (V) | CT |
| 56 | output C EIS9 current (A) | channel C object 19 | 4 Bytes | 14.19 electric current (A) | CT |
| 57 | input D switching | channel D object 1 | 1 Bit | 1.1 switch | CW |
| 58 | input D dimming | channel D object 2 | 4 Bit | 3.7 dimming control | CW |
| 59 | input D value | channel D object 3 | 1 Byte | 5.1 percentage (0..100%) | CW |
| 60 | output D switching status | channel D object 4 | 1 Bit | 1.1 switch | CT |
| 61 | output D value status | channel D object 5 | 1 Byte | 5.1 percentage (0..100%) | CT |
| 62 | input D inhibit | channel D object 6 | 1 Bit | 1.1 switch | CW |
| 63 | input D scenes | channel D object 7 | 1 Byte | 17.1 scene number | CW |
| 64 | input D sequence 1 | channel D object 8 | 1 Bit | 1.1 switch | CW |
| 65 | input D sequence 2 | channel D object 9 | 1 Bit | 1.1 switch | CW |
| 66 | output D gen. error | channel D object 10 | 1 Bit | 1.1 switch | CT |
| 67 | output D no mains error | channel D object 11 | 1 Bit | 1.1 switch | CT |
| 68 | output D overload error | channel D object 12 | 1 Bit | 1.1 switch | CT |
| 69 | output D EIS11 meter S/N | channel D object 13 | 4 Bytes | DPT.12 | CT |
| 70 | output D EIS1 meter status | channel D object 14 | 1 Bit | 1.1 switch | CT |
| 71 | output D EIS11 meter reading (kWh) | channel D object 15 | 4 Bytes | 13.13 active energy (kWh) | CT |
| 72 | output D EIS11 meter reading (Wh) | channel D object 16 | 4 Bytes | 13.10 active energy (Wh) | CT |
| 73 | output D EIS9 act. power (W) | channel D object 17 | 4 Bytes | 14.56 power (W) | CT |
| 74 | output D EIS9 voltage (V) | channel D object 18 | 4 Bytes | 14.27 electric potential (V) | CT |
| 75 | output D EIS9 current (A) | channel D object 19 | 4 Bytes | 14.19 electric current (A) | CT |
Parameters (99)
| Parameter | Type | Default |
|---|---|---|
| mode of operation | list | channel A master, channel B master |
| at bus voltage recovery | list | value before bus voltage failure |
| switching functions | list | no |
| timing functions | list | no |
| scenes | list | no |
| sequence 1 | list | no |
| sequence 2 | list | no |
| inhibit function | list | no |
| status and error messages | list | no |
| metering function | list | no |
| value when switching ON | list | MAX |
| ON with dimming | list | yes |
| OFF with dimming | list | yes |
| lower output limit | list | 30% |
| upper output limit | list | 100% |
| time for dimming (1..14400 s) (0%..100%) | unsignedInt 1…14400 | 5 |
| value is (also scenes, sequences and inhibit) | list | set fast |
| time for soft setting (1..14400 s) (0%..100%) | unsignedInt 1…14400 | 5 |
| soft ON | list | no |
| time for soft ON (1..14400 s) (0%..100%) | unsignedInt 1…14400 | 5 |
| soft OFF | list | no |
| time for soft OFF (1..14400 s) (100%..0%) | unsignedInt 1…14400 | 5 |
| time delay / blinking | list | none |
| time for ON delay (0..3600 s) | unsignedInt 0…3600 | 0 |
| time for OFF delay (0..3600 s) | unsignedInt 0…3600 | 0 |
| time for staircase function (1..3600 s) | unsignedInt 1…3600 | 180 |
| blinking ON time (1..3600 s) | unsignedInt 1…3600 | 180 |
| blinking OFF time (1..3600 s) | unsignedInt 1…3600 | 6 |
| scene 1 | list | no action |
| scene 2 | list | no action |
| scene 3 | list | no action |
| scene 4 | list | no action |
| scene 5 | list | no action |
| scene 6 | list | no action |
| scene 7 | list | no action |
| scene 8 | list | no action |
| scene 9 | list | no action |
| scene 10 | list | no action |
| scene 11 | list | no action |
| scene 12 | list | no action |
| scene 13 | list | no action |
| scene 14 | list | no action |
| scene 15 | list | no action |
| scene 16 | list | no action |
| scene 17 | list | no action |
| scene 18 | list | no action |
| scene 19 | list | no action |
| scene 20 | list | no action |
| scene 21 | list | no action |
| scene 22 | list | no action |
| scene 23 | list | no action |
| scene 24 | list | no action |
| scene 25 | list | no action |
| scene 26 | list | no action |
| scene 27 | list | no action |
| scene 28 | list | no action |
| scene 29 | list | no action |
| scene 30 | list | no action |
| scene 31 | list | no action |
| scene 32 | list | no action |
| enable scene saving | list | no |
| 1st action of sequence 1 | list | MAX |
| time between 1st and 2nd action (0..64800 s) | unsignedInt 0…64800 | 0 |
| 2nd action of sequence 1 | list | no action |
| time between 2nd and 3rd action (0..64800 s) | unsignedInt 0…64800 | 0 |
| 3rd action of sequence 1 | list | no action |
| time between 3rd and 4th action (0..64800 s) | unsignedInt 0…64800 | 0 |
| 4th action of sequence 1 | list | no action |
| action when object value = 0 | list | OFF |
| 1st action of sequence 2 | list | MAX |
| time between 1st and 2nd action (0..64800 s) | unsignedInt 0…64800 | 10 |
| 2nd action of sequence 2 | list | 30% |
| time between 2nd and 3rd action (0..64800 s) | unsignedInt 0…64800 | 1 |
| 3rd action of sequence 2 | list | MAX |
| time between 3rd and 4th action (0..64800 s) | unsignedInt 0…64800 | 3 |
| 4th action of sequence 2 | list | OFF |
| inhibit with | list | 1 (ON) |
| at bus voltage recovery set inhibit object to | list | 0 (OFF) |
| value when inhibit starts | list | no action |
| value when inhibit ends | list | no action |
| switching status | list | do not transmit |
| value status | list | do not transmit |
| general error message | list | do not transmit |
| no mains error message | list | do not transmit |
| overload error message | list | do not transmit |
| send meter readings cyclically (incl. meter status and meter S/N) | list | no |
| send instantaneous power cyclically | list | no |
| send instantaneous voltage cyclically | list | no |
| send instantaneous current cyclically | list | no |
| cycle time in s (5..3600) (for all metering objects) | unsignedInt 5…3600 | 300 |
| mode of operation | list | channel C master, channel D master |
| recording in 1st column | list | channel A meter reading hires (Wh) |
| recording in 2nd column | list | channel B meter reading hires (Wh) |
| recording in 3rd column | list | channel C meter reading hires (Wh) |
| recording in 4th column | list | channel D meter reading hires (Wh) |
| recording in 5th column | list | channel A temperature (°C) |
| recording in 6th column | list | channel B temperature (°C) |
| recording in 7th column | list | channel C temperature (°C) |
| recording in 8th column | list | channel D temperature (°C) |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| 4x dimming-FW, meters, scenes, sequences 3003-22 2.2 latest | $3003 | 7DB8 | 2026-11-25 | 100 KB | Download |
About this file
This is the official ETS product database for the Lingg & Janke dimmer switch 2 4fold 570W universal hand (DIM4FU-2-FW), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Lingg & Janke
- L&J secure dimmer switch 2 4fold 570W universal hand DIM4FU-2-SEC
- L&J secure dimmer switch 4fold DIM4FX-SEC
- AH3F16H-SEC switching actuator 3fold 79236-SEC
- AH5F16H-SEC switching actuator 5fold 79237-SEC
- AH9F16H-SEC switching actuator 9fold 79238-SEC
- COMIP-REG-1-SEC secure IP interface 87342-SEC
- TA4F55-BUDGET-SEC push button 4fold 87840-SEC
- TA4F55TH-BUDGET-SEC push button 4fold + temp. 87841-SEC
- LK4-1-SEC secure line coupler 88504-SEC
- L&J COMUSBC-REG-1 89342
- switching actuator 2fold A2FX-E-Q
- L&J secure switching actuator 2fold A2FX-SEC