KNX Database

4-Input, Push Button KTE4TS

Kanontec - KanonBUS · Order number KTE4TS · Multi-function Module › Universal Interface

with outputs

Download .knxprod 4-switch default 2.2 · 86 KB

Product

ManufacturerKanontec - KanonBUS
Product name4-Input, Push Button
Order numberKTE4TS
Product textPush Button, Input/Output
HardwareInput/Output Universal
MediumTwisted Pair
Bus current (mA)8
Rail mountedNo
RegistrationRegistered · 2023-02-24
Languagesen-US
Catalog entryM-0130_H-2.20.2F.2F.20KTExTSK3-2_HP-1052-22-C800_CI-KTE4TS-1
FingerprintC800
SHA-256d788073372af538f563818adc24b4681aefaf103c1f6863f5b939ac7f41a0eb5
First seen2026-11-25
Markets59 markets

Application program: 4-switch default 2.2

Application number$1052
Version2.2
Mask versionMV-0021 (2.1)
KNX Data SecureNo
Parameters336
Group objects67
Group objects (67)
NoNameFunctionSizeDPTFlags
0Input 1Short operation1 Bit1.7 stepCT
0Input 1Switch1 Bit1.1 switchCWT
0Input 1Channel 1 switch short1 Bit1.1 switchCWT
0Input 1Channel 1 value short1 Byte5.10 counter pulses (0..255)CT
1Input 2Short operation1 Bit1.7 stepCT
1Input 2Switch1 Bit1.1 switchCWT
1Input 2Channel 1 switch short1 Bit1.1 switchCWT
1Input 2Channel 1 value short1 Byte5.10 counter pulses (0..255)CT
2Input 3Short operation1 Bit1.7 stepCT
2Input 3Switch1 Bit1.1 switchCWT
2Input 3Channel 1 switch short1 Bit1.1 switchCWT
2Input 3Channel 1 value short1 Byte5.10 counter pulses (0..255)CT
3Input 4Short operation1 Bit1.7 stepCT
3Input 4Switch1 Bit1.1 switchCWT
3Input 4Channel 1 switch short1 Bit1.1 switchCWT
3Input 4Channel 1 value short1 Byte5.10 counter pulses (0..255)CT
8Input 1Long operation1 Bit1.8 up/downCT
8Input 1Brightness value1 Byte5.1 percentage (0..100%)CT
8Input 1Temperature value2 Bytes9.1 temperature (°C)CT
8Input 1Scene extension input1 Byte18.1 scene controlCT
8Input 1Dimming value1 Byte5.1 percentage (0..100%)CT
8Input 1Dimming4 Bit3.7 dimming controlCT
8Input 1Disable1 Bit1.3 enableCWT
8Input 1Channel 2 switch long1 Bit1.1 switchCWT
8Input 1Channel 2 value long1 Byte5.10 counter pulses (0..255)CT
9Input 2Long operation1 Bit1.8 up/downCT
9Input 2Dimming4 Bit3.7 dimming controlCT
9Input 2Brightness value1 Byte5.1 percentage (0..100%)CT
9Input 2Temperature value2 Bytes9.1 temperature (°C)CT
9Input 2Scene extension input1 Byte18.1 scene controlCT
9Input 2Dimming value1 Byte5.1 percentage (0..100%)CT
9Input 2Disable1 Bit1.3 enableCWT
9Input 2Channel 2 switch long1 Bit1.1 switchCWT
9Input 2Channel 2 value long1 Byte5.10 counter pulses (0..255)CT
10Input 3Long operation1 Bit1.8 up/downCT
10Input 3Brightness value1 Byte5.1 percentage (0..100%)CT
10Input 3Temperature value2 Bytes9.1 temperature (°C)CT
10Input 3Scene extension input1 Byte18.1 scene controlCT
10Input 3Dimming value1 Byte5.1 percentage (0..100%)CT
10Input 3Dimming4 Bit3.7 dimming controlCT
10Input 3Disable1 Bit1.3 enableCWT
10Input 3Channel 2 switch long1 Bit1.1 switchCWT
10Input 3Channel 2 value long1 Byte5.10 counter pulses (0..255)CT
11Input 4Long operation1 Bit1.8 up/downCT
11Input 4Brightness value1 Byte5.1 percentage (0..100%)CT
11Input 4Temperature value2 Bytes9.1 temperature (°C)CT
11Input 4Scene extension input1 Byte18.1 scene controlCT
11Input 4Dimming value1 Byte5.1 percentage (0..100%)CT
11Input 4Dimming4 Bit3.7 dimming controlCT
11Input 4Disable1 Bit1.3 enableCWT
11Input 4Channel 2 switch long1 Bit1.1 switchCWT
11Input 4Channel 2 value long1 Byte5.10 counter pulses (0..255)CT
16Output 1Switch Output1 Bit1.1 switchCWU
17Output 2Switch Output1 Bit1.1 switchCWU
18Output 3Switch Output1 Bit1.1 switchCWU
19Output 1Switch Status1 Bit1.1 switchCRT
20Output 2Switch Status1 Bit1.1 switchCRT
21Output 3Switch Status1 Bit1.1 switchCRT
22Output 18-bit Scene1 Byte18.1 scene controlCW
23Output 28-bit Scene1 Byte18.1 scene controlCW
24Output 38-bit Scene1 Byte18.1 scene controlCW
25Backlight InputOn/Off1 Bit1.1 switchCWT
25Backlight OutputOn/Off1 Bit1.1 switchCRT
26Status LED 1Switch1 Bit1.1 switchCW
27Status LED 2Switch1 Bit1.1 switchCW
28Status LED 3Switch1 Bit1.1 switchCW
29Status LED 4Switch1 Bit1.1 switchCW
Parameters (117)
ParameterTypeDefault
GenerallistInput 1
Backlight Modelistalways ON
delay time after wake-up (second)unsignedInt 1…36005
wake-up by internal sensorlistYES
wake-up by any buttonslistYES
whether status LED is relatedlistYES
wake-up brightness (%)unsignedInt 10…100100
Backlight brightness (%)unsignedInt 10…100100
sleeping brightness (%)unsignedInt 0…800
Function of operational LEDlistON
Status-LED brightness (%)unsignedInt 10…100100
Function of Output 1listdisabled
Function of Output 2listdisabled
Function of Output 3listdisabled
Length of time status LEDs are lit for operational displaylist3 s
Low nibble: address of sending ICunsignedInt 0…6413
Local operation for adjustment of IR grouplistdisabled
Input 1listInput 1
Functionlistswitch
Function of status LEDliststatus display
Function of status LEDlistoperating display
Function of DisablelistNO
Function channel 1 (short)listSwitching (1 bit)
Command for Channel 1listTOGGLE
Value for Channel 1unsignedInt 0…255100
Function channel 2 (long)listSwitching (1 bit)
Command for Channel 2listTOGGLE
Value for Channel 2unsignedInt 0…2550
Command on operation of InputlistTOGGLE
Input functionlisttwo-level operation: brighter (ON)
Input functionlistUP
Input functionlistdimming value
Time between Channel 1 and Channel 2 (1...255 x 100 ms)unsignedInt 0…25530
Command on release of Inputlistno function
Base for time between short and long operationlist8 ms
Scene (1...64)unsignedInt 1…641
Temperature (0...40 °C)list20 °C
Brightness (0...1500 lux)list300 lux
Value (0...255)unsignedInt 0…255100
Base for time between switching and dimminglist130 ms
Factor for time between short and long operation (0...255)unsignedInt 0…25530
Factor for time between switching and dimming (2...127)unsignedInt 2…1273
Adjustment for louvrelistdisabled
Dim brighter bylist100 %
Base for time for louvre adjustmentlist8 ms
Dim darker bylist100 %
Dim darker by3list100 %
Factor for time for louvre adjustment (0...255)unsignedInt 0…255250
Adjustment via long Input actionlistdisabled
Repeat telegram?listNO
Interval between two telegramslist1 s
Interval between two telegramslist200 ms
Step width (1...10)unsignedInt 1…1010
Step widthlist1 °C
Step widthlist50 lux
Send stop telegram?listYES
Input 2listInput 2
Input functionlisttwo-level operation: darker (OFF)
Input functionlistDOWN
Scene (1...64)unsignedInt 1…642
Dim brighter by6list100 %
Input 3listInput 3
Scene (1...64)unsignedInt 1…643
Dim darker by8list100 %
Input 4listInput 4
Scene (1...64)unsignedInt 1…644
Dim brighter by4list100 %
Input 5listInput 5
Function6listswitch
Function of status LED8liststatus display
Function of status LEDlistLED always OFF
Input function5listtwo-level operation: brighter (ON)
Scene (1...64)unsignedInt 1…645
Base for time between switching and dimming5list130 ms
Factor for time between switching and dimming (2...127)8unsignedInt 2…1273
Dim brighter by8list100 %
Dim darker by7list100 %
Repeat telegram?4listNO
Send stop telegram?8listYES
Input 6listInput 6
Function7listswitch
Function of status LED2liststatus display
Input function1listtwo-level operation: darker (OFF)
Scene (1...64)unsignedInt 1…646
Base for time between switching and dimming3list130 ms
Factor for time between switching and dimming (2...127)5unsignedInt 2…1273
Dim brighter by2list100 %
Dim darker by2list100 %
Repeat telegram?5listNO
Send stop telegram?7listYES
Input 7listInput 7
Function2listswitch
Function of status LED4liststatus display
Input function7listtwo-level operation: brighter (ON)
Scene (1...64)unsignedInt 1…647
Base for time between switching and dimming1list130 ms
Factor for time between switching and dimming (2...127)6unsignedInt 2…1273
Dim brighter by1list100 %
Dim darker by1list100 %
Repeat telegram?1listNO
Send stop telegram?5listYES
Input 8listInput 8
Function3listswitch
Function of status LED1liststatus display
Input function3listtwo-level operation: darker (OFF)
Scene (1...64)unsignedInt 1…648
Base for time between switching and dimming6list130 ms
Factor for time between switching and dimming (2...127)7unsignedInt 2…1273
Dim brighter by3list100 %
Dim darker by4list100 %
Repeat telegram?8listNO
Send stop telegram?2listYES
Output 1: ScenelistInput 1
Channel is assigned to Scene (0=no allocation)unsignedInt 0…640
Standard valuelistOFF
Output 2: ScenelistInput 1
Output 3: ScenelistInput 1

Version history

ApplicationApp noFingerprintFirst seenSizeFile
4-switch default 2.2 latest$1052C8002026-11-2586 KBDownload

About this file

This is the official ETS product database for the Kanontec - KanonBUS 4-Input, Push Button (KTE4TS), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Kanontec - KanonBUS

All Kanontec - KanonBUS products