Multi-function Thermostat KTEx8W
Kanontec - KanonBUS · Order number KTEx8W · Multi-function Module › Multi-function Thermostat
Download .knxprod Multi-function module 1.1 · 69 KB
Product
| Manufacturer | Kanontec - KanonBUS |
|---|---|
| Product name | Multi-function Thermostat |
| Order number | KTEx8W |
| Hardware | Multi-function thermostat |
| Medium | Twisted Pair |
| Bus current (mA) | 8 |
| Rail mounted | No |
| Registration | Certified · 2023-02-20 |
| Languages | en-US |
| Catalog entry | M-0130_H-8.20.2F.2F.20KTE8W-1_HP-03ED-11-1571_CI-KTEx8W-1 |
| Fingerprint | 1571 |
| SHA-256 | 8ad9068bc82e662dec846e33873ae03cd7dceca709dd07990c58756261007e6c |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Multi-function module 1.1
| Application number | $03ED |
|---|---|
| Version | 1.1 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | No |
| Parameters | 71 |
| Group objects | 34 |
Group objects (34)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | AC - Output: Control_On/Off [1bit] | 0-Off;1-On | 1 Bit | 1.1 switch | CRT |
| 1 | AC - Output: Control_Mode [1byte] | Heat/Cool/Fan/Dry | 1 Byte | 20.105 HVAC control mode | CRT |
| 2 | AC - Output: Control_FanSpeed [1byte] | Low/Middle/High | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 3 | AC - Output: Control_Setpoint Temperature [EIS5] | celsius degree | 2 Bytes | 9.1 temperature (°C) | CRT |
| 4 | AC - Input: Status_On/Off [1bit] | 0-Off;1-On | 1 Bit | 1.1 switch | CW |
| 5 | AC - Input: Status_Mode [1byte] | Heat/Cool/Fan/Dry | 1 Byte | 20.105 HVAC control mode | CW |
| 6 | AC - Input: Status_FanSpeed [1byte] | Low/Middle/High | 1 Byte | 5.1 percentage (0..100%) | CW |
| 7 | AC - Input: Status_Setpoint Temperature [EIS5] | celsius degree | 2 Bytes | 9.1 temperature (°C) | CW |
| 8 | AC - Output: Fancoil - Valve | Cooling | 1 Bit | 1.1 switch | CRT |
| 9 | AC - Output: Fancoil - Valve | Heating | 1 Bit | 1.1 switch | CRT |
| 15 | Input: Backlight | On/Off | 1 Bit | 1.1 switch | CW |
| 20 | HEAT - Output: Control_On/Off [1bit] | 0-Off;1-On | 1 Bit | 1.1 switch | CRT |
| 21 | HEAT - Output: Control_Setpoint Temperature [EIS5] | celsius degree | 2 Bytes | 9.1 temperature (°C) | CRT |
| 22 | HEAT - Output: Valve | valve | 1 Bit | 1.1 switch | CRT |
| 23 | HEAT - Input: Status_On/Off [1bit] | 0-Off;1-On | 1 Bit | 1.1 switch | CW |
| 24 | HEAT - Input: Status_Setpoint Temperature [EIS5] | celsius degree | 2 Bytes | 9.1 temperature (°C) | CW |
| 28 | Pushbutton Left-3: Trigger | 8-bit Scene | 1 Byte | 18.1 scene control | CT |
| 30 | AIR - Output: Control_On/Off [1bit] | 0-Off;1-On | 1 Bit | 1.1 switch | CRT |
| 31 | AIR - Output: Control_Mode [1byte] | Auto/Internal/External | 1 Byte | CRT | |
| 32 | AIR - Output: Control_FanSpeed [1byte] | Low/Middle/High | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | AIR - Input: Status_On/Off [1bit] | 0-Off;1-On | 1 Bit | 1.1 switch | CW |
| 34 | AIR - Input: Status_Mode [1byte] | Auto/Internal/External | 1 Byte | CW | |
| 35 | AIR - Input: Status_FanSpeed [1byte] | Low/Middle/High | 1 Byte | 5.1 percentage (0..100%) | CW |
| 37 | AIR - Output: Control_FanSpeed [1bit] | Low | 1 Bit | 1.1 switch | CRWT |
| 38 | Pushbutton Left-4: Trigger | 8-bit Scene | 1 Byte | 18.1 scene control | CT |
| 38 | AIR - Output: Control_FanSpeed [1bit] | Middle | 1 Bit | 1.1 switch | CRWT |
| 39 | AIR - Output: Control_FanSpeed [1bit] | High | 1 Bit | 1.1 switch | CRWT |
| 40 | Input: Room Temperature [EIS5] | celsius degree | 2 Bytes | 9.1 temperature (°C) | CWT |
| 40 | Output: Room Temperature [EIS5] | celsius degree | 2 Bytes | 9.1 temperature (°C) | CRT |
| 41 | Sensor - Input: PM2.5 [EIS5] | ug/m3 | 2 Bytes | 9.8 parts/million (ppm) | CWT |
| 42 | Sensor - Input: CO2 [EIS5] | ppm | 2 Bytes | 9.8 parts/million (ppm) | CWT |
| 43 | Sensor - Input: RH% [2byte] | 0-100% | 2 Bytes | 9.7 humidity (%) | CWT |
| 43 | Output: Humidity(RH%) [2byte] | 0-100% | 2 Bytes | 9.7 humidity (%) | CRWT |
| 45 | Sensor - Input: dew-point [EIS5] | celsius degree | 2 Bytes | 9.1 temperature (°C) | CWT |
Parameters (60)
| Parameter | Type | Default |
|---|---|---|
| Backlight delay (second), 65535=Always ON | unsignedInt 2…65535 | 65535 |
| Function AC | list | Active |
| Air-condition type | list | VRV/VRF system |
| Function Heat | list | Inactive |
| Function AIR (Ventilation) | list | Inactive |
| Function Sensor - Room Temperature | list | Active |
| Room Temperature | list | Internal Sensor |
| Room Temperature Send-Type | list | transmit value in the event of changes |
| Room Temperature Cycle-time | list | 1 second |
| Room Temperature On-change (C) | unsignedInt 0…20 | 1 |
| Function Display - Humidity(RH) | list | Inactive |
| Humidity(RH) | list | External Sensor |
| Humidity(RH) Send-Type | list | transmit value in cycles |
| Humidity(RH) Cycle-time | list | 1 second |
| Humidity(RH) On-change (%) | unsignedInt 0…20 | 1 |
| Function Display - Dew-Point | list | Inactive |
| Function Display - TVOC | list | Inactive |
| Function Display - CO2 | list | Inactive |
| Function Display - PM2.5 | list | Inactive |
| Room Temperature Compensation (C) | list | 0 degree |
| Function AC - Setpoint Lowest (C) | unsignedInt 5…45 | 15 |
| Function AC - Setpoint Highest (C) | unsignedInt 5…45 | 35 |
| Function HEAT - Setpoint Lowest (C) | unsignedInt 5…45 | 15 |
| Function HEAT - Setpoint Highest (C) | unsignedInt 5…45 | 35 |
| Valve dead-band for Heating (C) | unsignedInt 0…20 | 1 |
| Valve dead-band for Cooling (C) | unsignedInt 0…20 | 1 |
| AC - Fan Speed Low | list | Active |
| Fan Speed Low value | unsignedInt 0…255 | 1 |
| AC - Fan Speed M1 | list | Inactive |
| Fan Speed M1 value | unsignedInt 0…255 | 4 |
| AC - Fan Speed Middle | list | Active |
| Fan Speed Middle value | unsignedInt 0…255 | 2 |
| AC - Fan Speed M2 | list | Inactive |
| Fan Speed M2 value | unsignedInt 0…255 | 5 |
| AC - Fan Speed High | list | Active |
| Fan Speed High value | unsignedInt 0…255 | 3 |
| AC - Fan Speed Auto | list | Active |
| Fan Speed Auto value | unsignedInt 0…255 | 0 |
| AC - Mode Cool | list | Active |
| Mode Cool value | unsignedInt 0…255 | 0 |
| AC - Mode Heat | list | Active |
| Mode Heat value | unsignedInt 0…255 | 1 |
| AC - Mode Fan | list | Active |
| Mode Fan value | unsignedInt 0…255 | 2 |
| AC - Mode Dry | list | Active |
| Mode Dry value | unsignedInt 0…255 | 3 |
| AC - Mode Auto | list | Inactive |
| Mode Auto value | unsignedInt 0…255 | 4 |
| Fan Speed object type | list | 1-byte value |
| AIR - Fan Speed Low | list | Active |
| AIR - Fan Speed Middle | list | Active |
| AIR - Fan Speed High | list | Active |
| AIR - Mode Auto | list | Active |
| Mode Auto value | unsignedInt 0…255 | 0 |
| AIR - Mode Cycle-inside | list | Active |
| Mode Cycle-inside value | unsignedInt 0…255 | 1 |
| AIR - Mode Cycle-outside | list | Active |
| Mode Cycle-outside value | unsignedInt 0…255 | 2 |
| Pushbutton Left 3 - Scene Number | unsignedInt 1…64 | 1 |
| Pushbutton Left 4 - Scene Number | unsignedInt 1…64 | 2 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Multi-function module 1.1 latest | $03ED | 1571 | 2026-11-25 | 69 KB | Download |
About this file
This is the official ETS product database for the Kanontec - KanonBUS Multi-function Thermostat (KTEx8W), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.