Interra ITR830-XX13 ITR830-XX13 Midea VRF AC-KNX Gateway

ITR830-XX13 Midea VRF AC-KNX Gateway ITR830-XX13

Interra · Order number ITR830-XX13 · Gateway

Download .knxprod ITR830 X1-X2 Port (VRF) 1.0 · 218 KB

Product

ManufacturerInterra
Product nameITR830-XX13 Midea VRF AC-KNX Gateway
Order numberITR830-XX13
Product textMidea VRF AC KNX Gateway
HardwareITR830-XX13 Midea VRF AC-KNX Gateway
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified · 2024-01-02
Languagesen-US
Catalog entryM-0107_H-ITR830.2DXX13-1_HP-034B-10-F063_CI-ITR830.2DXX13-1
FingerprintF063
SHA-256fae0fac2097391b4d324b2b278965fd718d9e4ad9c5b8f091f0382773377da17
First seen2026-11-25
Markets59 markets

Application program: ITR830 X1-X2 Port (VRF) 1.0

Application number$034B
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters341
Group objects1589
Group objects (1589)
NoNameFunctionSizeDPTFlags
1Alive beaconAlive beacon1 Bit1.2 booleanCT
2Logic 1 - Input 1Logic Input1 Bit1.2 booleanCRW
3Logic 1 - Input 2Logic Input1 Bit1.2 booleanCRW
4Logic 1 - Input 3Logic Input1 Bit1.2 booleanCRW
5Logic 1 - Input 4Logic Input1 Bit1.2 booleanCRW
6Logic 1 - OutputLogic Output1 Bit1.2 booleanCRT
7Logic 2 - Input 1Logic Input1 Bit1.2 booleanCRW
8Logic 2 - Input 2Logic Input1 Bit1.2 booleanCRW
9Logic 2 - Input 3Logic Input1 Bit1.2 booleanCRW
10Logic 2 - Input 4Logic Input1 Bit1.2 booleanCRW
11Logic 2 - OutputLogic Output1 Bit1.2 booleanCRT
12Logic 3 - Input 1Logic Input1 Bit1.2 booleanCRW
13Logic 3 - Input 2Logic Input1 Bit1.2 booleanCRW
14Logic 3 - Input 3Logic Input1 Bit1.2 booleanCRW
15Logic 3 - Input 4Logic Input1 Bit1.2 booleanCRW
16Logic 3 - OutputLogic Output1 Bit1.2 booleanCRT
17Logic 4 - Input 1Logic Input1 Bit1.2 booleanCRW
18Logic 4 - Input 2Logic Input1 Bit1.2 booleanCRW
19Logic 4 - Input 3Logic Input1 Bit1.2 booleanCRW
20Logic 4 - Input 4Logic Input1 Bit1.2 booleanCRW
21Logic 4 - OutputLogic Output1 Bit1.2 booleanCRT
22Converter 1 - Input (1 Bit)Converter Input1 Bit1.6 binary valueCRW
23Converter 1 - Input (2 Bits)Converter Input2 Bit2.6 binary value controlCRW
24Converter 1 - Input (1 Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRW
25Converter 1 - Input (2 Bytes)Converter Input2 Bytes7.1 pulsesCRW
26Converter 1 - Output (1 Bit)Converter Output1 Bit1.6 binary valueCRWT
27Converter 1 - Output (2 Bits)Converter Output2 Bit2.6 binary value controlCRWT
28Converter 1 - Output (1 Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
29Converter 1 - Output (2 Bytes)Converter Output2 Bytes7.1 pulsesCRWT
30Converter 2 - Input (1 Bit)Converter Input1 Bit1.6 binary valueCRW
31Converter 2 - Input (2 Bits)Converter Input2 Bit2.6 binary value controlCRW
32Converter 2 - Input (1 Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRW
33Converter 2 - Input (2 Bytes)Converter Input2 Bytes7.1 pulsesCRW
34Converter 2 - Output (1 Bit)Converter Output1 Bit1.6 binary valueCRWT
35Converter 2 - Output (2 Bits)Converter Output2 Bit2.6 binary value controlCRWT
36Converter 2 - Output (1 Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
37Converter 2 - Output (2 Bytes)Converter Output2 Bytes7.1 pulsesCRWT
38Converter 3 - Input (1 Bit)Converter Input1 Bit1.6 binary valueCRW
39Converter 3 - Input (2 Bits)Converter Input2 Bit2.6 binary value controlCRW
40Converter 3 - Input (1 Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRW
41Converter 3 - Input (2 Bytes)Converter Input2 Bytes7.1 pulsesCRW
42Converter 3 - Output (1 Bit)Converter Output1 Bit1.6 binary valueCRWT
43Converter 3 - Output (2 Bits)Converter Output2 Bit2.6 binary value controlCRWT
44Converter 3 - Output (1 Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
45Converter 3 - Output (2 Bytes)Converter Output2 Bytes7.1 pulsesCRWT
46Converter 4 - Input (1 Bit)Converter Input1 Bit1.6 binary valueCRW
47Converter 4 - Input (2 Bits)Converter Input2 Bit2.6 binary value controlCRW
48Converter 4 - Input (1 Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRW
49Converter 4 - Input (2 Bytes)Converter Input2 Bytes7.1 pulsesCRW
50Converter 4 - Output (1 Bit)Converter Output1 Bit1.6 binary valueCRWT
51Converter 4 - Output (2 Bits)Converter Output2 Bit2.6 binary value controlCRWT
52Converter 4 - Output (1 Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
53Converter 4 - Output (2 Bytes)Converter Output2 Bytes7.1 pulsesCRWT
54Converter 5 - Input (1 Bit)Converter Input1 Bit1.6 binary valueCRW
55Converter 5 - Input (2 Bits)Converter Input2 Bit2.6 binary value controlCRW
56Converter 5 - Input (1 Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRW
57Converter 5 - Input (2 Bytes)Converter Input2 Bytes7.1 pulsesCRW
58Converter 5 - Output (1 Bit)Converter Output1 Bit1.6 binary valueCRWT
59Converter 5 - Output (2 Bits)Converter Output2 Bit2.6 binary value controlCRWT
60Converter 5 - Output (1 Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
61Converter 5 - Output (2 Bytes)Converter Output2 Bytes7.1 pulsesCRWT
62Converter 6 - Input (1 Bit)Converter Input1 Bit1.6 binary valueCRW
63Converter 6 - Input (2 Bits)Converter Input2 Bit2.6 binary value controlCRW
64Converter 6 - Input (1 Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRW
65Converter 6 - Input (2 Bytes)Converter Input2 Bytes7.1 pulsesCRW
66Converter 6 - Output (1 Bit)Converter Output1 Bit1.6 binary valueCRWT
67Converter 6 - Output (2 Bits)Converter Output2 Bit2.6 binary value controlCRWT
68Converter 6 - Output (1 Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
69Converter 6 - Output (2 Bytes)Converter Output2 Bytes7.1 pulsesCRWT
70Converter 7 - Input (1 Bit)Converter Input1 Bit1.6 binary valueCRW
71Converter 7 - Input (2 Bits)Converter Input2 Bit2.6 binary value controlCRW
72Converter 7 - Input (1 Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRW
73Converter 7 - Input (2 Bytes)Converter Input2 Bytes7.1 pulsesCRW
74Converter 7 - Output (1 Bit)Converter Output1 Bit1.6 binary valueCRWT
75Converter 7 - Output (2 Bits)Converter Output2 Bit2.6 binary value controlCRWT
76Converter 7 - Output (1 Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
77Converter 7 - Output (2 Bytes)Converter Output2 Bytes7.1 pulsesCRWT
78Converter 8 - Input (1 Bit)Converter Input1 Bit1.6 binary valueCRW
79Converter 8 - Input (2 Bits)Converter Input2 Bit2.6 binary value controlCRW
80Converter 8 - Input (1 Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRW
81Converter 8 - Input (2 Bytes)Converter Input2 Bytes7.1 pulsesCRW
82Converter 8 - Output (1 Bit)Converter Output1 Bit1.6 binary valueCRWT
83Converter 8 - Output (2 Bits)Converter Output2 Bit2.6 binary value controlCRWT
84Converter 8 - Output (1 Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
85Converter 8 - Output (2 Bytes)Converter Output2 Bytes7.1 pulsesCRWT
86AC01 OnOff0-Off ;1-On1 Bit1.1 switchCW
87AC01 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
88AC01 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
89AC01 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
90AC01 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
90AC01 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
91AC01 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
91AC01 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
92AC01 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
93AC01 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
94AC01 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
95AC01 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
96AC01 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
97AC01 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
98AC01 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
99AC01 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
100AC01 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
101AC01 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
102AC01 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
102AC01 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
103AC01 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
104AC01 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
104AC01 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
105AC01 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
105AC01 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
106AC01 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
107AC01 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
108AC01 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
109AC01 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
110AC01 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
111AC01 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
112AC01 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
113AC01 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
114AC01 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
115AC01 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
116AC01 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
117AC01 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
118AC01 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
119AC01 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
120AC01 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
121AC01 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
122AC01 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
122AC01 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
123AC01 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
124AC01 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
125AC01 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
126AC01 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
126AC01 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
127AC01 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
128AC01 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
129AC01 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
130AC01 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
130AC01 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
131AC01 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
132AC01 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
132AC01 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
133AC01 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
134AC01 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
134AC01 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
135AC01 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
135AC01 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
136AC01 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
137AC01 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
138AC01 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
138AC01 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
139AC01 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
139AC01 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
140AC01 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
141AC01 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
142AC01 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
142AC01 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
143AC01 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
143AC01 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
144AC01 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
145AC01 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
146AC01 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
147AC01 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
148AC01 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
149AC01 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
150AC01 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
151AC01 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
152AC01 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
153AC01 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
154AC01 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
155AC01 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
156AC01 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
157AC01 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
157AC01 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
158AC01 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
159AC01 Error Code FeedbackError Code Information2 BytesCRT
160AC01 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
161AC01 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
162AC01 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
163AC01 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
164AC02 OnOff0-Off ;1-On1 Bit1.1 switchCW
165AC02 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
166AC02 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
167AC02 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
168AC02 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
168AC02 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
169AC02 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
169AC02 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
170AC02 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
171AC02 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
172AC02 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
173AC02 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
174AC02 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
175AC02 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
176AC02 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
177AC02 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
178AC02 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
179AC02 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
180AC02 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
180AC02 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
181AC02 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
182AC02 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
182AC02 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
183AC02 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
183AC02 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
184AC02 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
185AC02 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
186AC02 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
187AC02 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
188AC02 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
189AC02 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
190AC02 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
191AC02 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
192AC02 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
193AC02 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
194AC02 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
195AC02 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
196AC02 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
197AC02 Fan Speed Feedback1-Fan Speed 71 Bit1.2 booleanCRT
198AC02 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
199AC02 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
200AC02 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
200AC02 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
201AC02 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
202AC02 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
203AC02 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
204AC02 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
204AC02 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
205AC02 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
206AC02 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
207AC02 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
208AC02 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
208AC02 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
209AC02 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
210AC02 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
210AC02 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
211AC02 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
212AC02 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
212AC02 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
213AC02 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
213AC02 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
214AC02 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
215AC02 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
216AC02 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
216AC02 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
217AC02 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
217AC02 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
218AC02 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
219AC02 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
220AC02 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
220AC02 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
221AC02 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
221AC02 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
222AC02 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
223AC02 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
224AC02 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
225AC02 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
226AC02 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
227AC02 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
228AC02 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
229AC02 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
230AC02 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
231AC02 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
232AC02 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
233AC02 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
234AC02 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
235AC02 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
235AC02 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
236AC02 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
237AC02 Error Code FeedbackError Code Information2 BytesCRT
238AC02 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
239AC02 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
240AC02 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
241AC02 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
242AC3 OnOff0-Off ;1-On1 Bit1.1 switchCW
243AC3 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
244AC3 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
245AC3 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
246AC3 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
246AC3 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
247AC3 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
247AC3 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
248AC3 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
249AC3 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
250AC3 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
251AC3 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
252AC3 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
253AC3 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
254AC3 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
255AC3 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
256AC3 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
257AC3 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
258AC3 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
258AC3 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
259AC3 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
260AC3 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
260AC3 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
261AC3 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
261AC3 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
262AC3 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
263AC3 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
264AC3 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
265AC3 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
266AC3 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
267AC3 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
268AC3 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
269AC3 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
270AC3 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
271AC3 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
272AC3 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
273AC3 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
274AC3 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
275AC3 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
276AC3 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
277AC3 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
278AC3 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
278AC3 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
279AC3 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
280AC3 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
281AC3 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
282AC3 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
282AC3 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
283AC3 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
284AC3 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
285AC3 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
286AC3 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
286AC3 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
287AC3 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
288AC3 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
288AC3 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
289AC3 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
290AC3 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
290AC3 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
291AC3 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
291AC3 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
292AC3 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
293AC3 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
294AC3 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
294AC3 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
295AC3 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
295AC3 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
296AC3 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
297AC3 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
298AC3 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
298AC3 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
299AC3 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
299AC3 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
300AC3 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
301AC3 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
302AC3 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
303AC3 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
304AC3 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
305AC3 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
306AC3 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
307AC3 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
308AC3 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
309AC3 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
310AC3 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
311AC3 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
312AC3 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
313AC3 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
313AC3 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
314AC3 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
315AC3 Error Code FeedbackError Code Information2 BytesCRT
316AC3 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
317AC3 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
318AC3 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
319AC3 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
320AC4 OnOff0-Off ;1-On1 Bit1.1 switchCW
321AC4 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
322AC4 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
323AC4 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
324AC4 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
324AC4 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
325AC4 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
325AC4 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
326AC4 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
327AC4 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
328AC4 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
329AC4 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
330AC4 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
331AC4 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
332AC4 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
333AC4 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
334AC4 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
335AC4 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
336AC4 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
336AC4 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
337AC4 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
338AC4 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
338AC4 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
339AC4 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
339AC4 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
340AC4 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
341AC4 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
342AC4 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
343AC4 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
344AC4 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
345AC4 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
346AC4 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
347AC4 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
348AC4 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
349AC4 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
350AC4 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
351AC4 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
352AC4 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
353AC4 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
354AC4 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
355AC4 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
356AC4 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
356AC4 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
357AC4 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
358AC4 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
359AC4 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
360AC4 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
360AC4 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
361AC4 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
362AC4 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
363AC4 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
364AC4 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
364AC4 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
365AC4 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
366AC4 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
366AC4 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
367AC4 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
368AC4 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
368AC4 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
369AC4 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
369AC4 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
370AC4 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
371AC4 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
372AC4 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
372AC4 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
373AC4 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
373AC4 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
374AC4 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
375AC4 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
376AC4 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
376AC4 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
377AC4 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
377AC4 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
378AC4 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
379AC4 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
380AC4 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
381AC4 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
382AC4 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
383AC4 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
384AC4 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
385AC4 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
386AC4 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
387AC4 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
388AC4 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
389AC4 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
390AC4 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
391AC4 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
391AC4 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
392AC4 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
393AC4 Error Code FeedbackError Code Information2 BytesCRT
394AC4 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
395AC4 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
396AC4 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
397AC4 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
398AC5 OnOff0-Off ;1-On1 Bit1.1 switchCW
399AC5 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
400AC5 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
401AC5 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
402AC5 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
402AC5 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
403AC5 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
403AC5 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
404AC5 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
405AC5 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
406AC5 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
407AC5 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
408AC5 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
409AC5 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
410AC5 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
411AC5 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
412AC5 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
413AC5 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
414AC5 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
414AC5 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
415AC5 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
416AC5 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
416AC5 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
417AC5 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
417AC5 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
418AC5 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
419AC5 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
420AC5 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
421AC5 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
422AC5 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
423AC5 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
424AC5 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
425AC5 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
426AC5 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
427AC5 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
428AC5 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
429AC5 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
430AC5 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
431AC5 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
432AC5 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
433AC5 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
434AC5 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
434AC5 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
435AC5 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
436AC5 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
437AC5 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
438AC5 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
438AC5 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
439AC5 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
440AC5 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
441AC5 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
442AC5 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
442AC5 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
443AC5 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
444AC5 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
444AC5 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
445AC5 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
446AC5 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
446AC5 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
447AC5 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
447AC5 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
448AC5 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
449AC5 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
450AC5 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
450AC5 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
451AC5 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
451AC5 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
452AC5 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
453AC5 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
454AC5 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
454AC5 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
455AC5 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
455AC5 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
456AC5 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
457AC5 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
458AC5 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
459AC5 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
460AC5 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
461AC5 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
462AC5 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
463AC5 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
464AC5 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
465AC5 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
466AC5 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
467AC5 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
468AC5 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
469AC5 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
469AC5 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
470AC5 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
471AC5 Error Code FeedbackError Code Information2 BytesCRT
472AC5 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
473AC5 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
474AC5 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
475AC5 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
476AC6 OnOff0-Off ;1-On1 Bit1.1 switchCW
477AC6 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
478AC6 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
479AC6 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
480AC6 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
480AC6 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
481AC6 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
481AC6 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
482AC6 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
483AC6 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
484AC6 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
485AC6 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
486AC6 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
487AC6 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
488AC6 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
489AC6 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
490AC6 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
491AC6 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
492AC6 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
492AC6 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
493AC6 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
494AC6 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
494AC6 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
495AC6 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
495AC6 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
496AC6 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
497AC6 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
498AC6 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
499AC6 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
500AC6 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
501AC6 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
502AC6 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
503AC6 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
504AC6 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
505AC6 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
506AC6 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
507AC6 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
508AC6 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
509AC6 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
510AC6 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
511AC6 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
512AC6 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
512AC6 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
513AC6 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
514AC6 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
515AC6 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
516AC6 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
516AC6 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
517AC6 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
518AC6 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
519AC6 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
520AC6 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
520AC6 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
521AC6 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
522AC6 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
522AC6 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
523AC6 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
524AC6 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
524AC6 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
525AC6 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
525AC6 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
526AC6 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
527AC6 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
528AC6 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
528AC6 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
529AC6 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
529AC6 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
530AC6 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
531AC6 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
532AC6 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
532AC6 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
533AC6 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
533AC6 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
534AC6 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
535AC6 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
536AC6 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
537AC6 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
538AC6 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
539AC6 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
540AC6 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
541AC6 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
542AC6 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
543AC6 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
544AC6 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
545AC6 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
546AC6 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
547AC6 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
547AC6 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
548AC6 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
549AC6 Error Code FeedbackError Code Information2 BytesCRT
550AC6 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
551AC6 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
552AC6 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
553AC6 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
554AC7 OnOff0-Off ;1-On1 Bit1.1 switchCW
555AC7 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
556AC7 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
557AC7 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
558AC7 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
558AC7 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
559AC7 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
559AC7 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
560AC7 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
561AC7 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
562AC7 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
563AC7 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
564AC7 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
565AC7 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
566AC7 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
567AC7 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
568AC7 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
569AC7 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
570AC7 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
570AC7 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
571AC7 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
572AC7 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
572AC7 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
573AC7 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
573AC7 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
574AC7 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
575AC7 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
576AC7 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
577AC7 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
578AC7 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
579AC7 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
580AC7 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
581AC7 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
582AC7 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
583AC7 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
584AC7 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
585AC7 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
586AC7 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
587AC7 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
588AC7 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
589AC7 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
590AC7 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
590AC7 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
591AC7 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
592AC7 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
593AC7 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
594AC7 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
594AC7 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
595AC7 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
596AC7 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
597AC7 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
598AC7 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
598AC7 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
599AC7 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
600AC7 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
600AC7 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
601AC7 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
602AC7 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
602AC7 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
603AC7 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
603AC7 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
604AC7 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
605AC7 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
606AC7 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
606AC7 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
607AC7 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
607AC7 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
608AC7 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
609AC7 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
610AC7 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
610AC7 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
611AC7 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
611AC7 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
612AC7 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
613AC7 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
614AC7 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
615AC7 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
616AC7 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
617AC7 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
618AC7 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
619AC7 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
620AC7 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
621AC7 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
622AC7 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
623AC7 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
624AC7 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
625AC7 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
625AC7 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
626AC7 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
627AC7 Error Code FeedbackError Code Information2 BytesCRT
628AC7 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
629AC7 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
630AC7 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
631AC7 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
632AC8 OnOff0-Off ;1-On1 Bit1.1 switchCW
633AC8 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
634AC8 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
635AC8 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
636AC8 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
636AC8 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
637AC8 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
637AC8 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
638AC8 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
639AC8 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
640AC8 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
641AC8 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
642AC8 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
643AC8 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
644AC8 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
645AC8 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
646AC8 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
647AC8 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
648AC8 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
648AC8 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
649AC8 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
650AC8 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
650AC8 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
651AC8 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
651AC8 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
652AC8 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
653AC8 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
654AC8 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
655AC8 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
656AC8 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
657AC8 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
658AC8 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
659AC8 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
660AC8 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
661AC8 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
662AC8 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
663AC8 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
664AC8 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
665AC8 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
666AC8 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
667AC8 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
668AC8 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
668AC8 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
669AC8 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
670AC8 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
671AC8 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
672AC8 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
672AC8 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
673AC8 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
674AC8 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
675AC8 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
676AC8 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
676AC8 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
677AC8 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
678AC8 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
678AC8 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
679AC8 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
680AC8 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
680AC8 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
681AC8 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
681AC8 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
682AC8 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
683AC8 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
684AC8 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
684AC8 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
685AC8 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
685AC8 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
686AC8 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
687AC8 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
688AC8 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
688AC8 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
689AC8 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
689AC8 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
690AC8 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
691AC8 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
692AC8 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
693AC8 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
694AC8 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
695AC8 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
696AC8 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
697AC8 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
698AC8 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
699AC8 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
700AC8 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
701AC8 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
702AC8 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
703AC8 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
703AC8 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
704AC8 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
705AC8 Error Code FeedbackError Code Information2 BytesCRT
706AC8 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
707AC8 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
708AC8 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
709AC8 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
710AC9 OnOff0-Off ;1-On1 Bit1.1 switchCW
711AC9 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
712AC9 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
713AC9 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
714AC9 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
714AC9 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
715AC9 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
715AC9 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
716AC9 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
717AC9 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
718AC9 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
719AC9 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
720AC9 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
721AC9 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
722AC9 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
723AC9 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
724AC9 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
725AC9 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
726AC9 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
726AC9 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
727AC9 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
728AC9 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
728AC9 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
729AC9 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
729AC9 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
730AC9 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
731AC9 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
732AC9 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
733AC9 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
734AC9 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
735AC9 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
736AC9 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
737AC9 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
738AC9 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
739AC9 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
740AC9 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
741AC9 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
742AC9 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
743AC9 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
744AC9 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
745AC9 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
746AC9 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
746AC9 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
747AC9 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
748AC9 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
749AC9 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
750AC9 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
750AC9 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
751AC9 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
752AC9 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
753AC9 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
754AC9 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
754AC9 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
755AC9 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
756AC9 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
756AC9 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
757AC9 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
758AC9 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
758AC9 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
759AC9 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
759AC9 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
760AC9 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
761AC9 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
762AC9 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
762AC9 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
763AC9 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
763AC9 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
764AC9 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
765AC9 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
766AC9 Timer State0-Stop;1-Start1 Bit1.10 start/stopCW
766AC9 Timer State0-Start;1-Stop1 Bit1.10 start/stopCW
767AC9 Timer State Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
767AC9 Timer State Feedback0-Start;1-Stop1 Bit1.10 start/stopCRT
768AC9 Timer DurationValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
769AC9 Scene0-63 (Execute 1-64); 128-191 (Storage 1-64)1 Byte18.1 scene controlCRWTU
770AC9 Scene 1 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
771AC9 Scene 1 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
772AC9 Scene 2 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
773AC9 Scene 2 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
774AC9 Scene 3 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
775AC9 Scene 3 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
776AC9 Scene 4 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
777AC9 Scene 4 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
778AC9 Scene 5 Run0-Nothing;1-Run Scene1 Bit1.2 booleanCWT
779AC9 Scene 5 Storage0-Nothing;1-Storage Scene1 Bit1.2 booleanCWT
780AC9 Current Scene Feedback1-64:Current Scene1 Byte17.1 scene numberCRT
781AC9 Device Control Locking0-Enable;1-Disable1 Bit1.3 enableCW
781AC9 Device Control Locking0-Disable;1-Enable1 Bit1.3 enableCW
782AC9 Error Alarm Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
783AC9 Error Code FeedbackError Code Information2 BytesCRT
784AC9 Error Code Text FeedbackError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
785AC9 Working Hour Counter FeedbackWorking Hours Counter Feedback4 Bytes12.101 counter timemin (min)CRT
786AC9 Working Hour Alert Feedback0-No Alarm;1-Alarm1 Bit1.5 alarmCRT
787AC9 Reset Hours Counter0-No Action;1-Reset1 Bit1.15 resetCW
788AC10 OnOff0-Off ;1-On1 Bit1.1 switchCW
789AC10 OnOff_Feedback0-Off;1-On1 Bit1.1 switchCRT
790AC10 Operating_Mode1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCW
791AC10 Operating_Mode_Feedback1-Heat;3-Cool;9-Fan;14-Dry1 Byte20.105 HVAC control modeCRT
792AC10 Mode Cool/Heat0-Cool;1-Heat1 Bit1.100 cooling/heatingCW
792AC10 Mode Heat/Cool0-Heat;1-Cool1 Bit1.100 cooling/heatingCW
793AC10 Mode Cool/Heat Feedback0-Cool;1-Heat1 Bit1.100 cooling/heatingCRT
793AC10 Mode Heat/Cool Feedback0-Heat;1-Cool1 Bit1.100 cooling/heatingCRT
794AC10 Mode Heating_Percentage0%-Off;1%-100%-On+Heat1 Byte5.1 percentage (0..100%)CW
795AC10 Mode Cooling_Percentage0%-Off;1%-100%-On+Cool1 Byte5.1 percentage (0..100%)CW
796AC10 Mode Heat1-Set HEAT mode1 Bit1.2 booleanCW
797AC10 Mode Heat Feedback1-HEAT mode1 Bit1.2 booleanCRT
798AC10 Mode Cool1-Set COOL mode1 Bit1.2 booleanCW
799AC10 Mode Cool Feedback1-COOL mode1 Bit1.2 booleanCRT
800AC10 Mode Fan1-Set FAN mode1 Bit1.2 booleanCW
801AC10 Mode Fan Feedback1-FAN mode1 Bit1.2 booleanCRT
802AC10 Mode Dry1-Set DRY mode1 Bit1.2 booleanCW
803AC10 Mode Dry Feedback1-DRY mode1 Bit1.2 booleanCRT
804AC10 Mode +/-0-Decrease;1-Increase1 Bit1.7 stepCW
804AC10 Mode +/-0-Up;1-Down1 Bit1.8 up/downCW
805AC10 Operating Mode Text FeedbackText Feedback14 Bytes16.1 Character String (ISO 8859-1)CRT
806AC10 Fan Speed ScalingThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CW
806AC10 Fan Speed Enumerated0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CW
807AC10 Fan Speed Scaling Feedback% Percentage value 1 Byte5.1 percentage (0..100%)CRT
807AC10 Fan Speed Enumerated Feedback0-Auto;1-Speed1;...7-Speed7;1 Byte5.100 fan stage (0..255)CRT
808AC10 Fan Speed 1 Control1-Set Fan Speed 11 Bit1.2 booleanCW
809AC10 Fan Speed 1 Feedback1-Fan Speed 11 Bit1.2 booleanCRT
810AC10 Fan Speed 2 Control1-Set Fan Speed 21 Bit1.2 booleanCW
811AC10 Fan Speed 2 Feedback1-Fan Speed 21 Bit1.2 booleanCRT
812AC10 Fan Speed 3 Control1-Set Fan Speed 31 Bit1.2 booleanCW
813AC10 Fan Speed 3 Feedback1-Fan Speed 31 Bit1.2 booleanCRT
814AC10 Fan Speed 4 Control1-Set Fan Speed 41 Bit1.2 booleanCW
815AC10 Fan Speed 4 Feedback1-Fan Speed 41 Bit1.2 booleanCRT
816AC10 Fan Speed 5 Control1-Set Fan Speed 51 Bit1.2 booleanCW
817AC10 Fan Speed 5 Feedback1-Fan Speed 51 Bit1.2 booleanCRT
818AC10 Fan Speed 6 Control1-Set Fan Speed 61 Bit1.2 booleanCW
819AC10 Fan Speed 6 Feedback1-Fan Speed 61 Bit1.2 booleanCRT
820AC10 Fan Speed 7 Control1-Set Fan Speed 71 Bit1.2 booleanCW
821AC10 Fan Speed 7 Feedback1-Fan Speed 71 Bit1.2 booleanCRT
822AC10 Fan Speed Auto Control1-Set Fan Speed Auto1 Bit1.2 booleanCW
823AC10 Fan Speed Auto Feedback1-Fan Speed Auto1 Bit1.2 booleanCRT
824AC10 Fan Speed +/-0-Decrease;1-Increase1 Bit1.7 stepCW
824AC10 Fan Speed +/-0-Up;1-Down1 Bit1.8 up/downCW
825AC10 Fan Speed Text FeedbackFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
826AC10 Setpoint Temperature Control°C2 Bytes9.1 temperature (°C)CW
827AC10 Setpoint Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
828AC10 Setpoint Temperature +/-0-Decrease;1-Increase1 Bit1.7 stepCW
828AC10 Setpoint Temperature +/-0-Up;1-Down1 Bit1.8 up/downCW
829AC10 Ambient Temperature°C2 Bytes9.1 temperature (°C)CW
830AC10 Ambient Temperature Feedback°C2 Bytes9.1 temperature (°C)CRT
831AC10 Air Deflector Broadcast Value0-Swing;1-Pos1;...5-Pos51 ByteCW
832AC10 Air Deflector +/-0-Decrease;1-Increase1 Bit1.7 stepCW
832AC10 Air Deflector +/-0-Up;1-Down1 Bit1.8 up/downCW
833AC10 Air Deflector Feedback0-Swing;1-Pos1;...5-Pos51 ByteCRT
834AC10 Window Contact Status0-Opened;1-Closed1 Bit1.9 open/closeCRWT
834AC10 Window Contact Status0-Closed;1-Opened1 Bit1.19 window/doorCRWT
835AC10 Window Contact Off DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
836AC10 Standby 1 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
836AC10 Standby 1 Function0-Stop;1-Start1 Bit1.10 start/stopCW
837AC10 Standby 1 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
837AC10 Standby 1 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
838AC10 Standby 1 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
839AC10 Standby 1 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW
840AC10 Standby 2 Function0-Not occupied;1-Occupied1 Bit1.18 occupancyCW
840AC10 Standby 2 Function0-Stop;1-Start1 Bit1.10 start/stopCW
841AC10 Standby 2 Feedback0-Not occupied;1-Occupied1 Bit1.18 occupancyCRT
841AC10 Standby 2 Feedback0-Stop;1-Start1 Bit1.10 start/stopCRT
842AC10 Standby 2 DelayValues are accepted according to the data type of 20.0131 Byte20.13 time delayCW
843AC10 Standby 2 Setpoint Shifting°C2 Bytes9.1 temperature (°C)CW

First 1000 of 1589 group objects shown. Download the .knxprod for the full list.

Parameters (149)
ParameterTypeDefault
Alive beacon statelistDisable
Alive beacon output logic statelistvalue '1'
Alive beacon intervaltime5
Product selectionlist1 Channel
Behavior after bus voltage failurelistNo Reaction
Scene selectionlistScene 1
AC feedbacks time delay at startuptime10
Number of logic gateslistNo Logic Gate
TypelistAND
Send status onlistInput Triggered
Number of inputslist1 Input
Output behaviorlistNormal
Switch on delaytime0
Switch off delaytime0
Send feedback periodicallytime1
Switch on delaytime10
Switch off delaytime10
Number of ConverterslistNo Converter
Input typelist1 Bit
Logical OperatorslistDisable
Priority to "Operating mode Heat/Cool"listDisable
Text feedback for mode HEAT ->textHEAT
Text feedback for mode COOL ->textCOOL
Text feedback for mode FAN ->textFAN
Text feedback for mode DRY ->textDRY
Include AUTO fan mode in the sequencelistNo
Loop the sequencelistNo
Fan speed 1 lower limit (%)unsignedInt 0…2550
Fan speed 2 lower limit (%)unsignedInt 0…25514
Fan speed 3 lower limit (%)unsignedInt 0…25528
Fan speed 4 lower limit (%)unsignedInt 0…25542
Fan speed 5 lower limit (%)unsignedInt 0…25556
Text feedback for mode Fan Speed 1->textFAN SPEED 1
Text feedback for mode Fan Speed 2->textFAN SPEED 2
Text feedback for mode Fan Speed 3->textFAN SPEED 3
Text feedback for mode Fan Speed 4->textFAN SPEED 4
Text feedback for mode Fan Speed 5->textFAN SPEED 5
Include 'SWING' mode in the sequencelistNo
Feedback sending periodtime30
Setpoint temperature limit controllistDisable
Setpoint temperature lower limitunsignedInt 17…2517
Setpoint temperature higher limitunsignedInt 20…3030
NumberunsignedInt 1…641
Ac On/OfflistAC Off
Ac modelistFan
Ac fan speedlistAuto
Ac setpoint temperature (°C)unsignedInt 17…3020
Delaytime5
Setpoint for alerttime1
Switch-off time delaytime1
Reject AC On/Off actions if window is openlistDisable
Behavior after window is closed.listNo Reaction
Standby function delaytime1
Setpoint temperature shifting (°C)unsignedInt 0…50
Reject modifications during standbylistDisable
Behavior after standby functionlistNo Reaction
Setpoint temperature shifting statelistDisable
Timer durationtime60
Timer retriggablelistNo
Input valueunsignedInt 0…2550
Input valueunsignedInt 0…655350
Standby function scenelistScene 1
After window is closed scenelistScene 1
Indoor unit 1 addressunsignedInt 0…630
Input valueunsignedInt 0…10
Input valueunsignedInt 0…30
Lower limitunsignedInt 0…25525
Lower limitunsignedInt 0…6553525
Output valueunsignedInt 0…10
Output valueunsignedInt 0…30
Output valueunsignedInt 0…2550
Output valueunsignedInt 0…655350
Upper limitunsignedInt 0…25575
Upper limitunsignedInt 0…6553575
Output typelist1 Byte
Output typelist1 Bit
Cyclic send statelistDisable
Cyclic Send StatelistDisable
Ambient temperature referencelistAC indoor sensor temp
Calculation valueunsignedInt 0…2550
Calculation valueunsignedInt 0…655350
AC feedbacks send statelistDisable
AC feedback periodicallyunsignedInt 0…2550
Text feedback for mode Fan Auto->textFAN AUTO
Indoor unit 2 addressunsignedInt 0…631
Indoor unit 3 addressunsignedInt 0…632
Indoor unit 4 addressunsignedInt 0…633
Indoor unit 5 addressunsignedInt 0…634
Indoor unit 6 addressunsignedInt 0…635
Indoor unit 7 addressunsignedInt 0…636
Indoor unit 8 addressunsignedInt 0…637
Indoor unit 9 addressunsignedInt 0…638
Indoor unit 10 addressunsignedInt 0…639
Indoor unit 11 addressunsignedInt 0…6310
Indoor unit 12 addressunsignedInt 0…6311
Indoor unit 13 addressunsignedInt 0…6312
Indoor unit 14 addressunsignedInt 0…6313
Indoor unit 15 addressunsignedInt 0…6314
Indoor unit 16 addressunsignedInt 0…6315
Error Code (1 Bit)listDisable
Error Code (2 Bytes)listDisable
Error code (14 Chars)listDisable
Operating mode HVAC objectlistDisable
Feedback operating mode objects (1 Byte)listDisable
Operating mode Heat/Cool objectlistDisable
Operating mode percentage value objectslistDisable
Operating mode individual objectslistDisable
Feedback operating mode individual (1 Bit)listDisable
Operating mode +/- objectlistDisable
Feedback operating mode objects (14 Chars)listDisable
Fan level control & feedback objects (1 Byte)listDisable
Fan level control individual objectslistDisable
Feedback fan speed level individual (1 Bit)listDisable
Fan level control +/- objectlistDisable
Feedback fan speed text object (14 chars)listDisable
Setpoint temperature feedback send statelistDisable
Setpoint temperature +/- objectlistDisable
Enable ambient temperaturelistNo
Ambient temperature feedback send statelistPeriodically
Ambient temperature referencelistKNX bus
Air deflector controllistDisable
Air deflector control +/- objectlistDisable
Air deflector feedbacklistDisable
Device control lockinglistDisable
SCENE 1listDisable
Activation objectlistDisable
Storage functionlistDisable
SCENE 2listDisable
SCENE 3listDisable
SCENE 4listDisable
SCENE 5listDisable
Working hours counterlistDisable
Enable window contactlistDisable
Switch-off time delay statelistDisable
Enable standby functionlistDisable
Standby function delay statelistDisable
Behavior during standby functionlistSetpoint Temp Shift
Enable timer functionlistStop
PolaritylistNormal
Timer duration statelistVia parameter
Number of connected indoor unitunsignedInt 1…41
Number of connected indoor unitunsignedInt 1…81
Number of connected indoor unitunsignedInt 1…161
Gateway's communication role on communication portlistMaster
Number of connected indoor unitunsignedInt 1…11
Fan speed 6 lower limit (%)unsignedInt 0…25570
Fan speed 7 lower limit (%)unsignedInt 0…25584
Text feedback for mode Fan Speed 6->textFAN SPEED 6
Text feedback for mode Fan Speed 7->textFAN SPEED 7

Version history

ApplicationApp noFingerprintFirst seenSizeFile
ITR830 X1-X2 Port (VRF) 1.0 latest$034BF0632026-11-25218 KBDownload

About this file

This is the official ETS product database for the Interra ITR830-XX13 Midea VRF AC-KNX Gateway (ITR830-XX13), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.