Interra ITR830-0003 Daikin VRV&SKY AC Gateway

Daikin VRV&SKY AC Gateway ITR830-0003

Interra · Order number ITR830-0003 · Gateway

Download .knxprod ITR830-0003 - Daikin VRV&SKY AC Gateway 1.0 · 156 KB

Product

ManufacturerInterra
Product nameDaikin VRV&SKY AC Gateway
Order numberITR830-0003
HardwareDaikin VRV&SKY AC Gateway
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified · 2022-06-23
Languagesen-US
Catalog entryM-0107_H-ITR830.2D0003-1_HP-033E-10-3C6F_CI-ITR830.2D0003-1
Fingerprint3C6F
SHA-2564e233a0336a393383ac7378c6b6178072886b31577cb891b9d26c16d425a510f
First seen2026-11-25
Markets59 markets

Application program: ITR830-0003 - Daikin VRV&SKY AC Gateway 1.0

Application number$033E
Version1.0
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters373
Group objects218
Group objects (218)
NoNameFunctionSizeDPTFlags
0Alive Beacon1:True/0:False1 Bit1.2 booleanCRT
1Climate On/Off1:On/0:Off1 Bit1.1 switchCWT
2Feedback Climate On/Off1:On/0:Off1 Bit1.1 switchCRT
3Operating Mode0:Aut/1:Hea/3:Coo/9:Fan/14:Dry1 Byte20.105 HVAC control modeCWT
4Feedback Operating Mode0:Aut/1:Hea/3:Coo/9:Fan/14:Dry1 Byte20.105 HVAC control modeCT
5Operating Mode Heat/Cool1:Heat/0:Cool1 Bit1.100 cooling/heatingCWT
5Operating Mode Cool/Heat0:Heat/1:Cool1 Bit1.100 cooling/heatingCWT
6Feedback Operating Mode Heat/Cool1:Heat/0:Cool1 Bit1.100 cooling/heatingCRT
6Feedback Operating Mode Cool/Heat0:Heat/1:Cool1 Bit1.100 cooling/heatingCRT
7Heating Mode Percent Value0%:Off/1%-100%:On+Heat1 Byte5.1 percentage (0..100%)CWT
8Cooling Mode Percent Value0%:Off/1%-100%:On+Cool1 Byte5.1 percentage (0..100%)CWT
9Individual Mode Auto1:Set Mode Auto/0:Nothing1 Bit1.2 booleanCWT
10Feedback Individual Mode Auto1:Auto1 Bit1.2 booleanCRT
11Individual Mode Heat1:Set Mode Heat/0:Nothing1 Bit1.2 booleanCWT
12Feedback Individual Mode Heat1:Heat1 Bit1.2 booleanCRT
13Individual Mode Cool1:Set Mode Cool/0:Nothing1 Bit1.2 booleanCWT
14Feedback Individual Mode Cool1:Cool1 Bit1.2 booleanCRT
15Individual Mode Fan1:Set Mode Fan/0:Nothing1 Bit1.2 booleanCWT
16Feedback Individual Mode Fan1:Fan1 Bit1.2 booleanCRT
17Individual Mode Dry1:Set Mode Dry/0:Nothing1 Bit1.2 booleanCWT
18Feedback Individual Mode Dry1:Dry1 Bit1.2 booleanCRT
19Operating Mode +/-1:Increase/0:Decrease1 Bit1.8 up/downCWT
19Operating Mode +/-0:Up/1:Down1 Bit1.8 up/downCWT
20Feedback Operating Mode TextOperating Mode Text14 Bytes16.1 Character String (ISO 8859-1)CRT
21Fan Speed Enumerated1:Speed1/2:Speed21 Byte5.100 fan stage (0..255)CWT
21Fan Speed PercentThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CWT
21Fan Speed Enumerated1:Speed1...3:Speed31 Byte5.100 fan stage (0..255)CWT
21Fan Speed Enumerated0:Auto, 1:Speed1...3:Speed31 Byte5.100 fan stage (0..255)CWT
21Fan Speed Enumerated0:Auto, 1:Speed1, 2:Speed21 Byte5.100 fan stage (0..255)CWT
22Feedback Fan Speed1:Speed1/2:Speed21 Byte5.100 fan stage (0..255)CRT
22Feedback Fan Speed1:Speed1...3:Speed31 Byte5.100 fan stage (0..255)CRT
22Feedback Fan Speed0:Auto, 1:Speed1/2:Speed21 Byte5.100 fan stage (0..255)CRT
22Feedback Fan Speed0:Auto, 1:Speed1...3:Speed31 Byte5.100 fan stage (0..255)CRT
23Fan Speed Auto/Manual1:Auto/0:Manual1 Bit1.1 switchCWT
24Feedback Fan Speed Auto/Manual1:Auto/0:Manual1 Bit1.1 switchCRT
25Individual Fan Speed 11:Set Fan Speed 1/0:Nothing1 Bit1.2 booleanCWT
26Feedback Individual Fan Speed 11:Fan Speed 11 Bit1.2 booleanCRT
27Individual Fan Speed 21:Set Fan Speed 2/0:Nothing1 Bit1.2 booleanCWT
28Feedback Individual Fan Speed 21:Fan Speed 21 Bit1.2 booleanCRT
29Individual Fan Speed 31:Set Fan Speed 3/0:Nothing1 Bit1.2 booleanCWT
30Feedback Individual Fan Speed 31:Fan Speed 31 Bit1.2 booleanCRT
31Fan Speed +/-1:Increase/0:Decrease1 Bit1.8 up/downCWT
31Fan Speed +/-0:Up/1:Down1 Bit1.8 up/downCWT
32Feedback Fan Speed TextFan Speed Text14 Bytes16.1 Character String (ISO 8859-1)CRT
33Vanes Position PercentThreshold Defined in Parameter1 Byte5.1 percentage (0..100%)CWT
33Vanes Position Enumerated1:Pos1...4:Pos41 Byte5.10 counter pulses (0..255)CWT
33Vanes Position Enumerated1:Pos1...5:Pos51 Byte5.10 counter pulses (0..255)CWT
34Feedback Vanes Position1:Pos1...4:Pos41 Byte5.10 counter pulses (0..255)CRT
34Feedback Vanes Position1:Pos1...5:Pos51 Byte5.10 counter pulses (0..255)CRT
35Vanes Set Position 11:Set Position 1/0:Nothing1 Bit1.2 booleanCWT
36Feedback Vanes Position 11:Position 11 Bit1.2 booleanCRT
37Vanes Set Position 21:Set Position 2/0:Nothing1 Bit1.2 booleanCWT
38Feedback Vanes Position 21:Position 21 Bit1.2 booleanCRT
39Vanes Set Position 31:Set Position 3/0:Nothing1 Bit1.2 booleanCWT
40Feedback Vanes Position 31:Position 31 Bit1.2 booleanCRT
41Vanes Set Position 41:Set Position 4/0:Nothing1 Bit1.2 booleanCWT
42Feedback Vanes Position 41:Position 41 Bit1.2 booleanCRT
43Vanes Set Position 51:Set Position 5/0:Nothing1 Bit1.2 booleanCWT
44Feedback Vanes Position 51:Position 51 Bit1.2 booleanCRT
45Vanes Set Swing1:Swing/0:Off1 Bit1.1 switchCWT
46Feedback Vanes Swing1:Swing/0:Off1 Bit1.1 switchCRT
47Vanes Position -/+0:Up/1:Down1 Bit1.8 up/downCWT
47Vanes Position -/+1:Increase/0:Decrease1 Bit1.8 up/downCWT
48Feedback Vanes Position TextVanes Position Text14 Bytes16.1 Character String (ISO 8859-1)CRT
49Setpoint TemperatureTemperature (Celcius)2 Bytes9.1 temperature (°C)CWT
50Feedback Setpoint TemperatureTemperature (Celcius)2 Bytes9.1 temperature (°C)CRT
51Setpoint Temperature -/+0:Up/1:Down1 Bit1.8 up/downCWT
51Setpoint Temperature +/-1:Increase/0:Decrease1 Bit1.8 up/downCWT
52KNX Ambient TemperatureTemperature (Celcius)2 Bytes9.1 temperature (°C)CRWT
53Feedback Ambient TemperatureTemperature (Celcius)2 Bytes9.1 temperature (°C)CRT
54Window Contact Status1:Open/0:Close1 Bit1.19 window/doorCRWT
54Window Contact Status0:Open/1:Close1 Bit1.19 window/doorCRWT
55Window Switch-Off DelayValues ​​are accepted according to the data type of 20.0131 Byte20.13 time delayCWT
56Standby Function1:Occupied/0:Not Occupied1 Bit1.10 start/stopCWT
56Standby Function1:Start/0:Stop1 Bit1.10 start/stopCWT
57Feedback Standby Function1:Occupied/0:Not Occupied1 Bit1.10 start/stopCRT
57Feedback Standby Function1:Start/0:Stop1 Bit1.10 start/stopCRT
58Standby Function DelayValues ​​are accepted according to the data type of 20.0131 Byte20.13 time delayCWT
59Standby Function Setpoint ShiftingTemperature (Celcius)2 Bytes9.1 temperature (°C)CWT
60Standby Function Secondary DelayValues ​​are accepted according to the data type of 20.0131 Byte20.13 time delayCWT
61Standby Function Secondary Setpoint ShiftingTemperature (Celcius)2 Bytes9.1 temperature (°C)CWT
62Timer Function1:Start/0:Stop1 Bit1.10 start/stopCWT
62Timer Function0:Start/1:Stop1 Bit1.10 start/stopCWT
63Feedback Timer Function1:Start/0:Stop1 Bit1.10 start/stopCRT
63Feedback Timer Function0:Start/1:Stop1 Bit1.10 start/stopCRT
64Timer FunctionValues ​​are accepted according to the data type of 20.0131 Byte20.13 time delayCWT
65Energy Saver Mode1:Start/0:Stop1 Bit1.10 start/stopCWT
65Energy Saver Mode0:Start/1:Stop1 Bit1.10 start/stopCWT
66Feedback Energy Saver Mode1:Start/0:Stop1 Bit1.10 start/stopCRT
66Feedback Energy Saver Mode0:Start/1:Stop1 Bit1.10 start/stopCRT
67Energy Saver Mode Timer DurationValues ​​are accepted according to the data type of 20.0131 Byte20.13 time delayCWT
68Energy Saver Mode Setpoint ShiftingTemperature (Celcius)2 Bytes9.1 temperature (°C)CWT
69Energy Saver Mode Fan Speed1:Fan1/2:Fan2/3:Fan31 Byte5.100 fan stage (0..255)CWT
70Power Saver Mode1:Start/0:Stop1 Bit1.10 start/stopCWT
70Power Saver Mode0:Start/1:Stop1 Bit1.10 start/stopCWT
71Feedback Power Saver Mode1:Start/0:Stop1 Bit1.10 start/stopCRT
71Feedback Power Saver Mode0:Start/1:Stop1 Bit1.10 start/stopCRT
72Power Saver Timer DurationValues ​​are accepted according to the data type of 20.0131 Byte20.13 time delayCWT
73Power Saver Mode Setpoint ShiftingTemperature (Celcius)2 Bytes9.1 temperature (°C)CWT
74Power Saver Mode Fan Speed1:Fan1/2:Fan2/3:Fan31 Byte5.100 fan stage (0..255)CWT
75Winter Mode1:Start/0:Stop1 Bit1.10 start/stopCWT
75Winter Mode0:Start/1:Stop1 Bit1.10 start/stopCWT
76Feedback Winter Mode1:Start/0:Stop1 Bit1.10 start/stopCRT
76Feedback Winter Mode0:Start/1:Stop1 Bit1.10 start/stopCRT
77Winter Mode Timer DurationValues ​​are accepted according to the data type of 20.0131 Byte20.13 time delayCWT
78Winter Mode SetpointTemperature (Celcius)2 Bytes9.1 temperature (°C)CWT
79Winter Mode Fan Speed1:Fan1/2:Fan2/3:Fan31 Byte5.100 fan stage (0..255)CWT
80Summer Mode1:Start/0:Stop1 Bit1.10 start/stopCWT
80Summer Mode0:Start/1:Stop1 Bit1.10 start/stopCWT
81Feedback Summer Mode1:Start/0:Stop1 Bit1.10 start/stopCRT
81Feedback Summer Mode0:Start/1:Stop1 Bit1.10 start/stopCRT
82Summer Mode Timer DurationValues ​​are accepted according to the data type of 20.0131 Byte20.13 time delayCWT
83Summer Mode SetpointTemperature (Celcius)2 Bytes9.1 temperature (°C)CWT
84Summer Mode Fan Speed1:Fan1/2:Fan2/3:Fan31 Byte5.100 fan stage (0..255)CWT
85Scene1-64:Run/128+Scene:Storage1 Byte18.1 scene controlCWT
86Scene 1 Run1:Run Scene/0:Nothing1 Bit1.2 booleanCWT
87Scene 2 Run1:Run Scene/0:Nothing1 Bit1.2 booleanCWT
88Scene 3 Run1:Run Scene/0:Nothing1 Bit1.2 booleanCWT
89Scene 4 Run1:Run Scene/0:Nothing1 Bit1.2 booleanCWT
90Scene 5 Run1:Run Scene/0:Nothing1 Bit1.2 booleanCWT
91Scene 1 Storage1:Storage Scene/0:Nothing1 Bit1.2 booleanCWT
92Scene 2 Storage1:Storage Scene/0:Nothing1 Bit1.2 booleanCWT
93Scene 3 Storage1:Storage Scene/0:Nothing1 Bit1.2 booleanCWT
94Scene 4 Storage1:Storage Scene/0:Nothing1 Bit1.2 booleanCWT
95Scene 5 Storage1:Storage Scene/0:Nothing1 Bit1.2 booleanCWT
96Feedback Current Scene1-64:Current Scene1 Byte17.1 scene numberCRT
97Device Control Locking1:Enable/0:Disable1 Bit1.3 enableCWT
97Device Control Locking0:Enable/1:Disable1 Bit1.3 enableCWT
99Feedback Error Alarm1:Alarm/0:No Alarm1 Bit1.5 alarmCRT
100Feedback Error CodeError Code Information2 BytesCRT
101Feedback Error Code TextError Text Information14 Bytes16.1 Character String (ISO 8859-1)CRT
102Feedback Working Hours CounterWorking Hours Counter4 Bytes13.100 time lag (s)CRT
103Feedback Working Hours Alert1:Alarm/0:No Alarm1 Bit1.5 alarmCRT
104Reset Hours Counter1:Reset/0:Nothing1 Bit1.15 resetCWT
105Logic 1 - Input 1Logic Input1 Bit1.2 booleanCRWT
106Logic 1 - Input 2Logic Input1 Bit1.2 booleanCRWT
107Logic 1 - Input 3Logic Input1 Bit1.2 booleanCRWT
108Logic 1 - Input 4Logic Input1 Bit1.2 booleanCRWT
109Logic 1 - OutputLogic Output1 Bit1.2 booleanCRT
110Logic 2 - Input 1Logic Input1 Bit1.2 booleanCRWT
111Logic 2 - Input 2Logic Input1 Bit1.2 booleanCRWT
112Logic 2 - Input 3Logic Input1 Bit1.2 booleanCRWT
113Logic 2 - Input 4Logic Input1 Bit1.2 booleanCRWT
114Logic 2 - OutputLogic Output1 Bit1.2 booleanCRT
115Logic 3 - Input 1Logic Input1 Bit1.2 booleanCRWT
116Logic 3 - Input 2Logic Input1 Bit1.2 booleanCRWT
117Logic 3 - Input 3Logic Input1 Bit1.2 booleanCRWT
118Logic 3 - Input 4Logic Input1 Bit1.2 booleanCRWT
119Logic 3 - OutputLogic Output1 Bit1.2 booleanCRT
120Logic 4 - Input 1Logic Input1 Bit1.2 booleanCRWT
121Logic 4 - Input 2Logic Input1 Bit1.2 booleanCRWT
122Logic 4 - Input 3Logic Input1 Bit1.2 booleanCRWT
123Logic 4 - Input 4Logic Input1 Bit1.2 booleanCRWT
124Logic 4 - OutputLogic Output1 Bit1.2 booleanCRT
125Converter 1 - Input (1-Bit)Converter Input1 Bit1.6 binary valueCRWT
126Converter 1 - Input (2-Bit)Converter Input2 Bit2.6 binary value controlCRWT
127Converter 1 - Input (1-Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRWT
128Converter 1 - Input (2-Byte)Converter Input2 Bytes7.1 pulsesCRWT
129Converter 1 - Output (1-Bit)Converter Output1 Bit1.6 binary valueCRWT
130Converter 1 - Output (2-Bit)Converter Output2 Bit2.6 binary value controlCRWT
131Converter 1 - Output (1-Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
132Converter 1 - Output (2-Byte)Converter Output2 Bytes7.1 pulsesCRWT
133Converter 2 - Input (1-Bit)Converter Input1 Bit1.6 binary valueCRWT
134Converter 2 - Input (2-Bit)Converter Input2 Bit2.6 binary value controlCRWT
135Converter 2 - Input (1-Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRWT
136Converter 2 - Input (2-Byte)Converter Input2 Bytes7.1 pulsesCRWT
137Converter 2 - Output (1-Bit)Converter Output1 Bit1.6 binary valueCRWT
138Converter 2 - Output (2-Bit)Converter Output2 Bit2.6 binary value controlCRWT
139Converter 2 - Output (1-Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
140Converter 2 - Output (2-Byte)Converter Output2 Bytes7.1 pulsesCRWT
141Converter 3 - Input (1-Bit)Converter Input1 Bit1.6 binary valueCRWT
142Converter 3 - Input (2-Bit)Converter Input2 Bit2.6 binary value controlCRWT
143Converter 3 - Input (1-Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRWT
144Converter 3 - Input (2-Byte)Converter Input2 Bytes7.1 pulsesCRWT
145Converter 3 - Output (1-Bit)Converter Output1 Bit1.6 binary valueCRWT
146Converter 3 - Output (2-Bit)Converter Output2 Bit2.6 binary value controlCRWT
147Converter 3 - Output (1-Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
148Converter 3 - Output (2-Byte)Converter Output2 Bytes7.1 pulsesCRWT
149Converter 4 - Input (1-Bit)Converter Input1 Bit1.6 binary valueCRWT
150Converter 4 - Input (2-Bit)Converter Input2 Bit2.6 binary value controlCRWT
151Converter 4 - Input (1-Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRWT
152Converter 4 - Input (2-Byte)Converter Input2 Bytes7.1 pulsesCRWT
153Converter 4 - Output (1-Bit)Converter Output1 Bit1.6 binary valueCRWT
154Converter 4 - Output (2-Bit)Converter Output2 Bit2.6 binary value controlCRWT
155Converter 4 - Output (1-Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
156Converter 4 - Output (2-Byte)Converter Output2 Bytes7.1 pulsesCRWT
157Converter 5 - Input (1-Bit)Converter Input1 Bit1.6 binary valueCRWT
158Converter 5 - Input (2-Bit)Converter Input2 Bit2.6 binary value controlCRWT
159Converter 5 - Input (1-Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRWT
160Converter 5 - Input (2-Byte)Converter Input2 Bytes7.1 pulsesCRWT
161Converter 5 - Output (1-Bit)Converter Output1 Bit1.6 binary valueCRWT
162Converter 5 - Output (2-Bit)Converter Output2 Bit2.6 binary value controlCRWT
163Converter 5 - Output (1-Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
164Converter 5 - Output (2-Byte)Converter Output2 Bytes7.1 pulsesCRWT
165Converter 6 - Input (1-Bit)Converter Input1 Bit1.6 binary valueCRWT
166Converter 6 - Input (2-Bit)Converter Input2 Bit2.6 binary value controlCRWT
167Converter 6 - Input (1-Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRWT
168Converter 6 - Input (2-Byte)Converter Input2 Bytes7.1 pulsesCRWT
169Converter 6 - Output (1-Bit)Converter Output1 Bit1.6 binary valueCRWT
170Converter 6 - Output (2-Bit)Converter Output2 Bit2.6 binary value controlCRWT
171Converter 6 - Output (1-Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
172Converter 6 - Output (2-Byte)Converter Output2 Bytes7.1 pulsesCRWT
173Converter 7 - Input (1-Bit)Converter Input1 Bit1.6 binary valueCRWT
174Converter 7 - Input (2-Bit)Converter Input2 Bit2.6 binary value controlCRWT
175Converter 7 - Input (1-Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRWT
176Converter 7 - Input (2-Byte)Converter Input2 Bytes7.1 pulsesCRWT
177Converter 7 - Output (1-Bit)Converter Output1 Bit1.6 binary valueCRWT
178Converter 7 - Output (2-Bit)Converter Output2 Bit2.6 binary value controlCRWT
179Converter 7 - Output (1-Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
180Converter 7 - Output (2-Byte)Converter Output2 Bytes7.1 pulsesCRWT
181Converter 8 - Input (1-Bit)Converter Input1 Bit1.6 binary valueCRWT
182Converter 8 - Input (2-Bit)Converter Input2 Bit2.6 binary value controlCRWT
183Converter 8 - Input (1-Byte)Converter Input1 Byte5.10 counter pulses (0..255)CRWT
184Converter 8 - Input (2-Byte)Converter Input2 Bytes7.1 pulsesCRWT
185Converter 8 - Output (1-Bit)Converter Output1 Bit1.6 binary valueCRWT
186Converter 8 - Output (2-Bit)Converter Output2 Bit2.6 binary value controlCRWT
187Converter 8 - Output (1-Byte)Converter Output1 Byte5.10 counter pulses (0..255)CRWT
188Converter 8 - Output (2-Byte)Converter Output2 Bytes7.1 pulsesCRWT
Parameters (164)
ParameterTypeDefault
Module alive beaconlistDisabled
> Module alive beacon interval (sec)unsignedInt 1…6553521
Behaviour after bus voltage failurelistNo reaction
> Scene selectionlistScene 1
Feedback at startuplistDisabled
> Feedback startup time delay (sec)unsignedInt 0…2550
Send feedback periodicallylistDisabled
Device control lockinglistDisabled
Error code (2-byte)listDisabled
Error code (14-char)listDisabled
Logic gate countlistNo logic gate
LOGIC GATE 1text
> TypelistAND
> Send status onlistEach input event
> Number of inputslist1 Input
> Output behaviourlistNormal
> Switch on delay (sec)unsignedInt 0…2550
> Switch off delay (sec)unsignedInt 0…2550
> Send feedback periodicallylistDisabled
LOGIC GATE 2text
LOGIC GATE 3text
LOGIC GATE 4text
Converter gate countlistNo converter gate
> Input typelist1 Bit
> CalculationlistDisabled
> Input valueunsignedInt 0…30
> Input valueunsignedInt 0…10
> Lower limitunsignedInt 0…2550
> Input valueunsignedInt 0…2550
> Input valueunsignedInt 0…655350
> Lower limitunsignedInt 0…655350
> Output typelist1 Bit
> Calculation valueunsignedInt 0…2550
> Output valueunsignedInt 0…10
> Output valueunsignedInt 0…30
> Output valueunsignedInt 0…2550
> Higher limitunsignedInt 0…2550
> Calculation valueunsignedInt 0…655350
> Output valueunsignedInt 0…655350
> Higher limitunsignedInt 0…655350
> Output typelist1 byte
CONVERTER 1text
CONVERTER 2text
CONVERTER 3text
CONVERTER 4text
CONVERTER 5text
CONVERTER 6text
CONVERTER 7text
CONVERTER 8text
> Output valuetextNon-zero value sets output to 1
Operating mode Heat/Cool object (1-bit)listDisabled
Operating mode +/- object (1-bit)listDisabled
Operating mode individual objects (1-bit)listDisabled
Operating mode object (1-byte)listDisabled
Operating mode percent value objectslistDisabled
> Priority to "Operating mode Heat/Cool"listDisabled
Feedback operating mode individual objects (1-bit)listDisabled
Feedback operating mode object (1-byte)listDisabled
Feedback operating mode text object (14-char)listDisabled
> Text for mode AUTOtextAUTO
> Text for mode HEATtextHEAT
> Text for mode COOLtextCOOL
> Text mode for FANtextFAN
> Text mode for DRYtextDRY
Energy Saver modelistDisabled
> Polaritylist1:Start / 0:Stop
> TimerlistDisabled
> Interval (min)unsignedInt 0…2550
> Setpoint shiftinglistVia parameter
> Value (ºC)unsignedInt 1…41
> Fan speedlistVia parameter
> Value (fan)listNo change
Power Saver modelistDisabled
Winter modelistDisabled
> SetpointlistVia parameter
> Value (ºC)unsignedInt 16…3018
Summer modelistDisabled
Fan mode availablelistNo
Number of fan levelunsignedInt 2…32
AUTO fan mode availablelistNo
Fan level control +/- object (1-bit)listDisabled
> Include AUTO fan mode in the sequencelistNo
> Loop the sequencelistNo
Fan level control individual objects (1-bit)listDisabled
Fan level control & feedback objects (1-byte)listDisabled
> Fan 1 lower limit (%)unsignedInt 0…1000
> Fan 2 lower limit (%)unsignedInt 0…10030
> Fan 3 lower limit (%)unsignedInt 0…10070
Feedback fan level individual objects (1-bit)listDisabled
Feedback fan level text object (14-char)listDisabled
> Text for speed AUTOtextAUTO
> Text for fan speed 1textFAN 1
> Text for fan speed 2textFAN 2
> Text for fan speed 3textFAN 3
Vanes control availablelistNo
Available vanes positionsunsignedInt 4…54
Vanes control +/- objects (1-bit)listDisabled
> Include SWING vanes mode in the sequencelistNo
Vanes control individual objects (1-bit)listDisabled
Vanes control & feedback objects (1-byte)listDisabled
> Vanes position 1 lower limitunsignedInt 0…1000
> Vanes position 2 lower limitunsignedInt 0…10020
> Vanes position 3 lower limitunsignedInt 0…10040
> Vanes position 4 lower limitunsignedInt 0…10060
> Vanes position 5 lower limitunsignedInt 0…10080
Feedback vanes control individual objects (1-bit)listDisabled
Feedback vanes control text objects (14-char)listDisabled
> Text for vanes SWINGtextSWING
> Text for vanes Position 1textPOSITION 1
> Text for vanes Position 2textPOSITION 2
> Text for vanes Position 3textPOSITION 3
> Text for vanes Position 4textPOSITION 4
> Text for vanes Position 5textPOSITION 5
Ac Unit Indoor Temperature Reference(Gateway must be master)listIndoor temperature sending disabled
Sending of AC internal temperaturelistOn change
> Period of sending (sec)unsignedInt 1…2551
Sending of AC setpoint temperaturelistOn change
Setpoint control +/- object (1-bit)listDisabled
Limits for setpoint controllistDisabled
> Setpoint lower limitunsignedInt 16…3016
> Setpoint higher limitunsignedInt 16…3030
SCENE 1listDisabled
> NumberunsignedInt 1…641
> AC On/OfflistOn
> AC ModelistAuto
> AC Fan levellistFan 1
> AC Vanes positionlistPos 2
> AC Setpoint temperaturelistNot Involved
> Storage functionlistDisabled
> Delay (sec)unsignedInt 0…2550
> Activation object (1-bit)listDisabled
SCENE 2listDisabled
> NumberunsignedInt 1…642
SCENE 3listDisabled
> NumberunsignedInt 1…643
SCENE 4listDisabled
> NumberunsignedInt 1…644
SCENE 5listDisabled
> NumberunsignedInt 1…645
Working hours counterlistDisabled
> Setpoint for alert (hour)unsignedInt 1…655351
Enable window contactlistDisabled
> Switch-off time delaylistVia parameter
> Switch-off time delay (min)unsignedInt 0…2550
> Reject On/Off actions if window is openlistDisabled
> Behavior after window is closelistNo reaction - Last state
Enable standby functionlistDisabled
> Standby function delaylistVia parameter
> Standby function delay (min)unsignedInt 0…2550
> Behavior during standby functionlistSetpoint shifting
> Setpoint shifting (°C)unsignedInt 1…41
> Activate secondary standby actionlistDisabled
> Secondary standby action delaylistVia parameter
> Secondary standby action delay (min)unsignedInt 1…2551
> Behavior during secondary standby functionlistSetpoint shifting
> Secondary setpoint shiftinglistVia parameter
> Secondary setpoint shifting (°C)unsignedInt 1…41
> Reject modifications during standby functionlistDisabled
> Behavior after standby functionlistNo reaction - Last state
Enable timer functionlistDisabled
> Timer durationlistVia parameter
> Timer duration (min)unsignedInt 1…655351
> Timer retriggerablelistNo
Remote Controller Connected (if set to "yes", Remote Controller must be master)listNo

Version history

ApplicationApp noFingerprintFirst seenSizeFile
ITR830-0003 - Daikin VRV&SKY AC Gateway 1.0 latest$033E3C6F2026-11-25156 KBDownload

About this file

This is the official ETS product database for the Interra Daikin VRV&SKY AC Gateway (ITR830-0003), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Interra

All Interra products