[683 732 rfs] 2-Channel actuator/blind actuator 683 732 rfs
Hugo Müller GmbH & Co KG · Order number 683 732 rfs · KNX-RF+ Devices › Actuators
Download .knxprod KNX-RF 1.R 2-channel switching actuator/shutter actuator 1.0 · 149 KB
Product
| Manufacturer | Hugo Müller GmbH & Co KG |
|---|---|
| Product name | [683 732 rfs] 2-Channel actuator/blind actuator |
| Order number | 683 732 rfs |
| Product text | KNX-RF 2-Kanal Schaltaktor/Jalousieaktor |
| Hardware | 2-Channel actuator/blind actuator |
| Medium | KNX RF |
| Rail mounted | No |
| Registration | Registered · 2020-02-28 |
| Languages | es-ES, de-DE |
| Catalog entry | M-00FC_H-SN2020.2E02.2E10-1-O009A_HP-FF44-10-46AC-O009A_CI-683.20732.20rfs-1 |
| Fingerprint | 46AC |
| SHA-256 | 725cdf018ef087f12b41d1d1bc4e6079ed6a4dc2a9aba9974cf5cb635009a4c4 |
| First seen | 2026-11-25 |
| Markets | 56 markets |
Application program: KNX-RF 1.R 2-channel switching actuator/shutter actuator 1.0
| Application number | $FF44 |
|---|---|
| Version | 1.0 |
| Mask version | MV-27B0 (RF System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 285 |
| Group objects | 105 |
Group objects (105)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | [Out1] Switch Feedback | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CT |
| 2 | [Out1] Switch On/Off | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 3 | [Out1] Forced positioning 2 Bits | Forced control | 2 Bit | 2.1 switch control | CW |
| 3 | [Out1] Forced positioning 1 Bit | 1 = Forced, 0 = Not Forced | 1 Bit | 1.1 switch | CW |
| 4 | [Out1] Change Threshold 1 value | 1 Byte value | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 4 | [Out1] Change Threshold 1 value | 2 Bytes value | 2 Bytes | 7.1 pulses | CW |
| 5 | [Out1] Threshold Input | 1 Byte value | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 5 | [Out1] Threshold Input | 2 Bytes value | 2 Bytes | 7.1 pulses | CW |
| 6 | [Out1] Logical connection 1 | 1 = True, 0 = False | 1 Bit | 1.2 boolean | CW |
| 7 | [Out1] Logical connection 2 | 1 = True, 0 = False | 1 Bit | 1.2 boolean | CW |
| 8 | [Out1] Scene | Scene Control | 1 Byte | 18.1 scene control | CW |
| 9 | [Out1] Set Preset 1/2 | Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 2 | 1 Bit | 1.1 switch | CW |
| 10 | [Out1] Call Preset 1/2 | Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 2 | 1 Bit | 1.3 enable | CW |
| 11 | [Out1] Time Switch | 1 = Timed On | 1 Bit | 1.10 start/stop | CW |
| 12 | [Out1] Stair Lighting Warning | 1 = Warning, 0 = No warning | 1 Bit | 1.1 switch | CT |
| 13 | [Out1] Time of Staircase Light (sec) | 2 Bytes value | 2 Bytes | 7.5 time (s) | CW |
| 14 | [Out1] Permanent ON | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 15 | [Out1] Disable Time Function | 1 = Disable, 0 = Enable | 1 Bit | 1.3 enable | CW |
| 16 | [Out2] Switch Feedback | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CT |
| 17 | [Out2] Switch On/Off | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 18 | [Out2] Forced positioning 2 Bits | Forced control | 2 Bit | 2.1 switch control | CW |
| 18 | [Out2] Forced positioning 1 Bit | 1 = Forced, 0 = Not Forced | 1 Bit | 1.1 switch | CW |
| 19 | [Out2] Change Threshold 1 value | 1 Byte value | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 19 | [Out2] Change Threshold 1 value | 2 Bytes value | 2 Bytes | 7.1 pulses | CW |
| 20 | [Out2] Threshold Input | 1 Byte value | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 20 | [Out2] Threshold Input | 2 Bytes value | 2 Bytes | 7.1 pulses | CW |
| 21 | [Out2] Logical connection 1 | 1 = True, 0 = False | 1 Bit | 1.2 boolean | CW |
| 22 | [Out2] Logical connection 2 | 1 = True, 0 = False | 1 Bit | 1.2 boolean | CW |
| 23 | [Out2] Scene | Scene Control | 1 Byte | 18.1 scene control | CW |
| 24 | [Out2] Set Preset 1/2 | Telegram 0 --> Set Preset 1, Telegram 1 --> Set Preset 2 | 1 Bit | 1.1 switch | CW |
| 25 | [Out2] Call Preset 1/2 | Telegram 0 --> Call Preset 1, Telegram 1 --> Call Preset 2 | 1 Bit | 1.3 enable | CW |
| 26 | [Out2] Time Switch | 1 = Timed On | 1 Bit | 1.10 start/stop | CW |
| 27 | [Out2] Stair Lighting Warning | 1 = Warning, 0 = No warning | 1 Bit | 1.1 switch | CT |
| 28 | [Out2] Time of Staircase Light (sec) | 2 Bytes value | 2 Bytes | 7.5 time (s) | CW |
| 29 | [Out2] Permanent ON | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 30 | [Out2] Disable Time Function | 1 = Disable, 0 = Enable | 1 Bit | 1.3 enable | CW |
| 31 | [Out] Blind Move Up/Down | 0 = Up, 1 = Down | 1 Bit | 1.8 up/down | CW |
| 31 | [Out] Louver Move Up/Down | 0 = Up, 1 = Down | 1 Bit | 1.8 up/down | CW |
| 31 | [Out] Roller Move Up/Down | 0 = Up, 1 = Down | 1 Bit | 1.8 up/down | CW |
| 32 | [Out] Louver Stop / Step Up/Down | 0 = Step Up, 1 = Step Down | 1 Bit | 1.7 step | CW |
| 32 | [Out] Blind Stop / Step Up/Down | 0 = Step Up, 1 = Step Down | 1 Bit | 1.7 step | CW |
| 32 | [Out] Roller Stop / Step Up/Down | 0 = Step Up, 1 = Step Down | 1 Bit | 1.7 step | CW |
| 33 | [Out] Forced Input | 2 Bits control | 2 Bit | 2.1 switch control | CW |
| 34 | [Out] Wind Alarm Input 1 | 1 = Alarm, 0 = No Alarm | 1 Bit | 1.5 alarm | CW |
| 35 | [Out] Wind Alarm Input 2 | 1 = Alarm, 0 = No Alarm | 1 Bit | 1.5 alarm | CW |
| 36 | [Out] Wind Alarm Input 3 | 1 = Alarm, 0 = No Alarm | 1 Bit | 1.5 alarm | CW |
| 37 | [Out] Rain Alarm Input | 1 = Alarm, 0 = No Alarm | 1 Bit | 1.5 alarm | CW |
| 38 | [Out] Frost Alarm Input | 1 = Alarm, 0 = No Alarm | 1 Bit | 1.5 alarm | CW |
| 39 | [Out] Scene Input | Scene Control | 1 Byte | 18.1 scene control | CW |
| 40 | [Out] Movement Feedback | 0 = Up, 1 = Down | 1 Bit | 1.8 up/down | CT |
| 41 | [Out] Blind position Input | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CW |
| 41 | [Out] Roller position Input | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CW |
| 41 | [Out] Louver position Input | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CW |
| 42 | [Out] Slats position Input | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CW |
| 43 | [Out] Blind position Feedback | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 43 | [Out] Roller position Feedback | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 43 | [Out] Louver position Feedback | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 44 | [Out] Slats position Feedback | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 45 | [Out] Lux level Input | Lux value | 2 Bytes | 9.4 lux (Lux) | CW |
| 45 | [Out] Sun Protection Input | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 46 | [Out] Sun Protection position Input | 0% = Open, 100% = Closed | 1 Byte | 5.1 percentage (0..100%) | CW |
| 50 | [Aux1] Switch On/Off Output Short press | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CT |
| 51 | [Aux1] Dimming Up/Down Output | Dimming control | 4 Bit | 3.7 dimming control | CT |
| 52 | [Aux1] Switch Feedback | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 53 | [Aux1] Switch On/Off Output Long press | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CT |
| 54 | [Aux1] Switch Long Feedback | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 55 | [Aux1] Scene Number Output | Scene Number control | 1 Byte | 18.1 scene control | CT |
| 56 | [Aux1] 1 Bit value Output | 1 Bit Value | 1 Bit | 1.1 switch | CT |
| 56 | [Aux1] 2 Bits value Output | 2 Bits value | 2 Bit | 2.1 switch control | CT |
| 56 | [Aux1] 1 Byte value Output | 1 Byte value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 56 | [Aux1] 2 Bytes value Output | 2 bytes value | 2 Bytes | 7.1 pulses | CT |
| 56 | [Aux1] 4 Bytes value Output | 4 Bytes value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 57 | [Aux1] 4 Bytes value Output Long press | 4 Bytes value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 57 | [Aux1] 2 Bits value Output Long press | 2 Bits value | 2 Bit | 2.1 switch control | CT |
| 57 | [Aux1] 1 Bit value Output Long press | 1 Bit Value | 1 Bit | 1.1 switch | CT |
| 57 | [Aux1] 1 Byte value Output Long press | 1 Byte value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 57 | [Aux1] 2 Bytes value Output Long press | 2 bytes value | 2 Bytes | 7.1 pulses | CT |
| 58 | [Aux1] Blind Stop / Step Up/Down | 0 = Step Up, 1 = Step Down | 1 Bit | 1.7 step | CT |
| 59 | [Aux1] Blind Move Up/Down | 0 = Up, 1 = Down | 1 Bit | 1.8 up/down | CT |
| 60 | GODUMMY1_AUX0 | GODUMMY1_AUX0 | 4 Bytes | DPT.12 | CWT |
| 61 | GODUMMY2_AUX0 | GODUMMY2_AUX0 | 4 Bytes | DPT.12 | CWT |
| 62 | GODUMMY3_AUX0 | GODUMMY3_AUX0 | 4 Bytes | DPT.12 | CWT |
| 63 | GODUMMY4_AUX0 | GODUMMY4_AUX0 | 4 Bytes | DPT.12 | CWT |
| 64 | [Aux2] Switch On/Off Output Short press | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CT |
| 65 | [Aux2] Dimming Up/Down Output | Dimming control | 4 Bit | 3.7 dimming control | CT |
| 66 | [Aux2] Switch Feedback | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 67 | [Aux2] Switch On/Off Long press Output | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CT |
| 68 | [Aux2] Switch Long Feedback | 1 = On, 0 = Off | 1 Bit | 1.1 switch | CW |
| 69 | [Aux2] Scene Number Output | Scene Number control | 1 Byte | 18.1 scene control | CT |
| 70 | [Aux2] 2 Bytes value Output | 2 bytes value | 2 Bytes | 7.1 pulses | CT |
| 70 | [Aux2] 4 Bytes value Output | 4 Bytes value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 70 | [Aux2] 1 Bit value Output | 1 Bit Value | 1 Bit | 1.1 switch | CT |
| 70 | [Aux2] 2 Bits value Output | 2 Bits value | 2 Bit | 2.1 switch control | CT |
| 70 | [Aux2] 1 Byte value Output | 1 Byte value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 71 | [Aux2] 1 Bit value Output Long press | 1 Bit Value | 1 Bit | 1.1 switch | CT |
| 71 | [Aux1] 2 Bits value Output Long press | 2 Bits value | 2 Bit | 2.1 switch control | CT |
| 71 | [Aux2] 2 Bytes value Output Long press | 2 bytes value | 2 Bytes | 7.1 pulses | CT |
| 71 | [Aux2] 1 Byte value Output Long press | 1 Byte value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 71 | [Aux2] 4 Bytes value Output Long press | 4 Bytes value | 4 Bytes | 12.1 counter pulses (unsigned) | CT |
| 72 | [Aux2] Blind Stop / Step Up/Down | 0 = Step Up, 1 = Step Down | 1 Bit | 1.7 step | CT |
| 73 | [Aux2] Blind Move Up/Down | 0 = Up, 1 = Down | 1 Bit | 1.8 up/down | CT |
| 74 | GODUMMY1_AUX1 | GODUMMY1_AUX1 | 4 Bytes | DPT.12 | CWT |
| 75 | GODUMMY2_AUX1 | GODUMMY2_AUX1 | 4 Bytes | DPT.12 | CWT |
| 76 | GODUMMY3_AUX1 | GODUMMY3_AUX1 | 4 Bytes | DPT.12 | CWT |
| 77 | GODUMMY4_AUX1 | GODUMMY4_AUX1 | 4 Bytes | DPT.12 | CWT |
Parameters (184)
| Parameter | Type | Default |
|---|---|---|
| Transmision and switching delay after recovery of voltage (2..255s) | unsignedInt 2…255 | 2 |
| Operating Mode | list | 2-channel Switch Actuator |
| RASTRO_ETS | unsignedInt 0…255 | 16 |
| Status response of switching state | list | No |
| Switching status object value | list | Closed = 1, Open = 0 |
| Disable relay switching with zero-cross control | unsignedInt 0…1 | 0 |
| "Switch" object value after recovering voltage | list | Set object to "0" |
| Output polarity | list | Normally Open contact |
| Enable Time function | unsignedInt 0…1 | 0 |
| Time function | list | Staircase light time switch |
| "Disable Time function" object value after recovering voltage | list | "0": Enable Time Function |
| Enable Preset function | unsignedInt 0…1 | 0 |
| Enable Scene (8 Bits) function | unsignedInt 0…1 | 0 |
| Enable Logical function | unsignedInt 0…1 | 0 |
| Enable Forced function | unsignedInt 0…1 | 0 |
| Enable Threshold function | unsignedInt 0…1 | 0 |
| Staircase light time switch timing (sec) | unsignedInt 0…65535 | 0 |
| Timer is retriggerable | unsignedInt 0…1 | 0 |
| Staircase light time switch can be switched off | list | ON with "1", OFF with "0" |
| Warning before end of time | list | No |
| Warning time (sec) | unsignedInt 0…65535 | 16 |
| Staircase time can be changed via object | unsignedInt 0…1 | 0 |
| On delay time (sec) | unsignedInt 0…65535 | 1 |
| Off delay time (sec) | unsignedInt 0…65535 | 1 |
| Flashing when "Timed Switch" object is | list | On (1) |
| Flash On time (sec) | unsignedInt 0…65535 | 5 |
| Flash Off time (sec) | unsignedInt 0…65535 | 5 |
| Reaction on Preset 1 (telegram 0) | list | No action |
| Reaction on Preset 2 (telegram 1) | list | No action |
| Preset can be set via bus | unsignedInt 0…1 | 0 |
| Scene 1 number | list | Scene 1 |
| Scene 1 Value | list | Off |
| Scene 2 number | list | Scene 2 |
| Scene 2 Value | list | Off |
| Scene 3 number | list | Scene 3 |
| Scene 3 Value | list | Off |
| Scene 4 number | list | Scene 4 |
| Scene 4 Value | list | Off |
| Scene 5 number | list | Scene 5 |
| Scene 5 Value | list | Off |
| Enable Logical Connection 1 | unsignedInt 0…1 | 1 |
| Logical Connection 1 function | list | AND |
| Logical Connection 1 Inverted | unsignedInt 0…1 | 0 |
| "Logical Connection 1" object value after recovering voltage | list | On |
| Enable Logical Connection 2 | unsignedInt 0…1 | 0 |
| Logical Connection 2 function | list | AND |
| Logical Connection 2 Inverted | unsignedInt 0…1 | 0 |
| "Logical Connection 1" object value after recovering voltage | list | Off |
| "Forced" object type | list | 1 Bit object |
| "Forced" object polarity | list | Forced object = 1 --> Switch Off |
| "Forced" object state after recovering voltage | list | Not Forced |
| Data type of object "Threshold Input" | list | 1 Byte (0..255) |
| Change Threshold value 1 over the bus | unsignedInt 0…1 | 0 |
| Threshold value 1 (0..255) | unsignedInt 0…255 | 0 |
| Threshold value 2 (0..255) | unsignedInt 0…255 | 15 |
| Threshold value 1 (0..65535) | unsignedInt 0…65535 | 0 |
| Threshold value 2 (0..65535) | unsignedInt 0…65535 | 50000 |
| Threshold values define Hysteresis | unsignedInt 0…1 | 0 |
| Threshold Input object value after recovering voltage | unsignedInt 0…255 | 0 |
| Threshold Input object value after recovering voltage | unsignedInt 0…65535 | 0 |
| Object value < Threshold value 1 | list | No action |
| Object value > Threshold value 2 | list | No action |
| Threshold 1 ≤ Object value ≤ Threshold 2 | list | No action |
| Warning time to add (sec) | unsignedInt 0…65535 | 16 |
| Type of device | list | Venetian Blind |
| Behaviour after recovering voltage | list | No action |
| Venting Louver position (0-100%) after recovering voltage | unsignedInt 0…100 | 0 |
| Slats position (0-100%) after recovering voltage | unsignedInt 0…100 | 0 |
| Extra time for "Up" movement (%) | unsignedInt 0…50 | 30 |
| Forced vs Weather Alarm Priority | list | 1- Forced operation 2 - Weather Alarm |
| Reversion Pause Time (msec) | unsignedInt 499…5000 | 500 |
| Step operation possible | list | Yes |
| Step Time (x 0,1sec) | unsignedInt 2…600 | 10 |
| Blind Movement Time (sec) | unsignedInt 1…3600 | 1 |
| Slats Movement Time (x 0,1sec) | unsignedInt 2…600 | 20 |
| Time to send "Current position" (sec) | unsignedInt 60…3600 | 60 |
| Time to send "Slats position" (sec) | unsignedInt 60…3600 | 60 |
| Enable "Movement Feedback" object | unsignedInt 0…1 | 0 |
| Enable Security features | unsignedInt 0…1 | 0 |
| Enable "Wind Alarm 1" object | unsignedInt 0…1 | 0 |
| Enable "Wind Alarm 2" object | unsignedInt 0…1 | 0 |
| Enable "Wind Alarm 3" object | unsignedInt 0…1 | 0 |
| Enable "Rain Alarm" object | unsignedInt 0…1 | 0 |
| Enable "Frost Alarm" object | unsignedInt 0…1 | 0 |
| Enable Wind alarm Watchdog | unsignedInt 0…1 | 0 |
| Wind Alarm Watchdog time (sec) | unsignedInt 10…65535 | 10 |
| Enable Rain Alarm Watchdog | unsignedInt 0…1 | 0 |
| Rain Alarm Watchdog time (sec) | unsignedInt 10…65535 | 10 |
| Enable Frost Alarm Watchdog | unsignedInt 0…1 | 0 |
| Frost Alarm Watchdog time (sec) | unsignedInt 10…65535 | 10 |
| Response to Wind Alarm | list | No action |
| Behaviour at the end of the Wind Alarm | list | No action |
| Response to Rain Alarm | list | No action |
| Behaviour at the end of the Rain Alarm | list | No action |
| Response to Frost Alarm | list | No action |
| Behaviour at the end of the Frost Alarm | list | No action |
| Weather Alarms priority | list | Wind > Rain > Frost |
| Enable Sun Protection | unsignedInt 0…1 | 0 |
| Protection object type | list | 1 Bit On/Off Protection object |
| Sun Protection object polarity | list | "1": Sun Protection On |
| Lux value to initiate protection | unsignedInt 1…3600 | 1000 |
| Lux value to end protection | unsignedInt 1…3600 | 500 |
| Delay time to initiate Sun Protection (sec) | unsignedInt 1…3600 | 1 |
| Action on Sun Protection | list | No action |
| Scene Number | list | Scene 1 |
| Position (%) | unsignedInt 0…100 | 0 |
| Slats position (%) | unsignedInt 0…100 | 0 |
| Delay time to end Sun Protection (sec) | unsignedInt 1…3600 | 1 |
| Sun Protection end action | list | No action |
| Enable Scene functionality | unsignedInt 0…1 | 0 |
| Scene 1 Position (%) | unsignedInt 0…100 | 0 |
| Scene 2 Position (%) | unsignedInt 0…100 | 0 |
| Scene 3 Position (%) | unsignedInt 0…100 | 0 |
| Scene 4 Position (%) | unsignedInt 0…100 | 0 |
| Scene 5 Position (%) | unsignedInt 0…100 | 0 |
| Scene 6 number | list | Scene 6 |
| Scene 6 Position (%) | unsignedInt 0…100 | 0 |
| Scene 7 number | list | Scene 7 |
| Scene 7 Position (%) | unsignedInt 0…100 | 0 |
| Scene 8 number | list | Scene 8 |
| Scene 8 position (%) | unsignedInt 0…100 | 0 |
| Scene 1 Position Slats (%) | unsignedInt 0…100 | 0 |
| Scene 2 Position Slats (%) | unsignedInt 0…100 | 0 |
| Scene 3 Position Slats (%) | unsignedInt 0…100 | 0 |
| Scene 4 Position Slats (%) | unsignedInt 0…100 | 0 |
| Scene 5 Position Slats (%) | unsignedInt 0…100 | 0 |
| Scene 6 Position Slats (%) | unsignedInt 0…100 | 0 |
| Scene 7 Position Slats (%) | unsignedInt 0…100 | 0 |
| Scene 8 position slats (%) | unsignedInt 0…100 | 0 |
| Forced state after recovering voltage | list | Not Forced |
| Fabric tensioning time (sec) | unsignedInt 0…255 | 0 |
| Enable "Blind position (%) Feedback" object | unsignedInt 0…1 | 0 |
| Enable "Slats position (%) Feedback" object | unsignedInt 0…1 | 0 |
| Auxiliary Pushbutton function | list | Switch |
| Debounce time | list | 30 msec |
| Distinction between Short and Long press | unsignedInt 0…1 | 0 |
| Number of objects for Short/Long press | list | 1 |
| Contact type | list | Normally Closed |
| Long press after | list | 0,4 sec |
| Long press | list | Off |
| Short press | list | On |
| Dimming functionality | list | Dimming and Switching |
| Action on Short press | list | Toggle |
| Action on Long press | list | Dim Brighter / Darker |
| Action on Short press | list | Call |
| Action on Long press | list | Save Scene |
| Value type on Short press | list | 1 Bit |
| Value type on Long press | list | 1 Bit |
| Bit value | list | 1 |
| 2 Bits value | list | "01" |
| 1 Byte value | unsignedInt 0…255 | 1 |
| 2 Bytes value | unsignedInt 0…65535 | 1 |
| 4 Bytes value | unsignedInt 0…4294967295 | 1 |
| Functional Construction | list | 1 Pushbutton |
| Shutter functionality | list | Short = Step, Long = Move |
| Action on Long press | list | Move Up |
| Action on Short press | list | Step Down |
| Action on Closing the contact | list | Toggle |
| Action on Opening the contact | list | Nothing |
| AUX0_DUMMY3 | unsignedInt 0…255 | 1 |
| AUX0_DUMMY4 | unsignedInt 0…255 | 1 |
| AUX0_DUMMY5 | unsignedInt 0…255 | 1 |
| AUX0_DUMMY6 | unsignedInt 0…255 | 1 |
| AUX0_DUMMY7 | unsignedInt 0…255 | 1 |
| AUX0_DUMMY8 | unsignedInt 0…65535 | 1 |
| AUX0_DUMMY9 | unsignedInt 0…65535 | 1 |
| AUX0_DUMMY10 | unsignedInt 0…65535 | 1 |
| Scene Number | list | Scene 2 |
| AUX1_DUMMY3 | unsignedInt 0…255 | 1 |
| AUX1_DUMMY4 | unsignedInt 0…255 | 1 |
| AUX1_DUMMY5 | unsignedInt 0…255 | 1 |
| AUX1_DUMMY6 | unsignedInt 0…255 | 1 |
| AUX1_DUMMY7 | unsignedInt 0…255 | 1 |
| AUX1_DUMMY8 | unsignedInt 0…65535 | 1 |
| AUX1_DUMMY9 | unsignedInt 0…65535 | 1 |
| AUX1_DUMMY10 | unsignedInt 0…65535 | 1 |
| Roller position (0-100%) after recovering voltage | unsignedInt 0…100 | 0 |
| Blind position (0-100%) after recovering voltage | unsignedInt 0…100 | 0 |
| Roller Movement Time (sec) | unsignedInt 1…3600 | 1 |
| Louver Movement Time (sec) | unsignedInt 1…3600 | 1 |
| Enable "Louver position Louver (%) Feedback" object | unsignedInt 0…1 | 0 |
| Enable "Roller position (%) Feedback" object | unsignedInt 0…1 | 0 |
| Action on press | list | Dim Brighter / Darker |
| Action on press | list | Move Up |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX-RF 1.R 2-channel switching actuator/shutter actuator 1.0 latest | $FF44 | 46AC | 2026-11-25 | 149 KB | Download |
About this file
This is the official ETS product database for the Hugo Müller GmbH & Co KG [683 732 rfs] 2-Channel actuator/blind actuator (683 732 rfs), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Hugo Müller GmbH & Co KG
- [683 010 rfs] Pushbutton interface 683 010 rfs
- [686 xxx rfs] Sensors 686 xxx rfs
- 683 xxx rfs 683 xxx rfs
- [879 443 knx] Dimmer – DALI, 3-channel 879 443 knx
- [AS 10.00 knx] Buzzer AS 10.00 knx
- [AS 26.01 knx] Gong interface AS 26.01 knx
- [AS 36.03 knx] Audio Interface AS 36.03 knx
- [EA 36.32 knx] Universal interface with binary inputs & outputs and room temperature control EA 36.32 knx
- [FU 40.00 knx] GPS sensor station with light/brightness and temperature sensor FU 40.00 knx
- [GS 30.12] Room climate-, humidity-, temperature controller GS 30.12 knx
- [GS 31.12] Room climate-, humidity-, temperature controller GS 31.12 knx
- [GS 37.11 knx] Room climate, humidity, temperature controllers GS 37.11 knx