Product

ManufacturerHugo Müller GmbH & Co KG
Product name[AS 26.01 knx] Gong interface
Order numberAS 26.01 knx
Product textAS 26.01 knx
HardwareAS 26.01 knx
MediumTwisted Pair
Bus current (mA)12
Rail mountedNo
RegistrationRegistered · 2021-01-15
Languagesde-DE, en-US
Catalog entryM-00FC_H-LP516-1_HP-2601-10-6C31_CI-AS.2026.2E01.20knx-1
Fingerprint6C31
SHA-256bad6e68aaf8a93b4b5252f2ba247ee5963b1da5e921fe6e9bf00990b6d7ce7ce
First seen2026-11-25
Markets56 markets

Application program: AS 26.01 knx 1.0

Application number$2601
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters429
Group objects100
Group objects (100)
NoNameFunctionSizeDPTFlags
2Send in operationOutput1 BitDPT.1CT
3Request statusInput1 BitDPT.1CW
4Mute functionInput1 BitDPT.1CW
5Global blocking objectInput1 BitDPT.1CW
6Day-/night operationInput1 BitDPT.1CW
7Activation object A: {{0}} Input1 BitDPT.1CW
8Blocking object activation object A: {{0}} Input1 BitDPT.1CW
9Volume activation object A: {{0}} Input1 ByteDPT.5CW
10Activation object B: {{0}}Input1 BitDPT.1CW
11Blocking object activation object B: {{0}} Input1 BitDPT.1CW
12Volume activation object B: {{0}} Input1 ByteDPT.5CW
13Activation object C: {{0}} Input1 BitDPT.1CW
14Blocking object activation object C: {{0}} Input1 BitDPT.1CW
15Volume activation object C: {{0}} Input1 ByteDPT.5CW
16Activation object D: {{0}}Input1 BitDPT.1CW
17Blocking object activation object D: {{0}} Input1 BitDPT.1CW
18Volume activation object D: {{0}} Input1 ByteDPT.5CW
19Activation object E: {{0}} Input1 BitDPT.1CW
20Blocking object activation object E: {{0}} Input1 BitDPT.1CW
21Volume activation object E: {{0}} Input1 ByteDPT.5CW
22Activation object F: {{0}}Input1 BitDPT.1CW
23Blocking object activation object F: {{0}} Input1 BitDPT.1CW
24Volume activation object F: {{0}} Input1 ByteDPT.5CW
25Activation object G: {{0}} Input1 BitDPT.1CW
26Blocking object activation object G: {{0}} Input1 BitDPT.1CW
27Volume activation object G: {{0}} Input1 ByteDPT.5CW
28Activation object H: {{0}}Input1 BitDPT.1CW
29Blocking object activation object H: {{0}} Input1 BitDPT.1CW
30Volume activation object H: {{0}} Input1 ByteDPT.5CW
31Activation object I: {{0}} Input1 BitDPT.1CW
32Blocking object activation object I: {{0}} Input1 BitDPT.1CW
33Volume activation object I: {{0}} Input1 ByteDPT.5CW
34Activation object J: {{0}}Input1 BitDPT.1CW
35Blocking object activation object J: {{0}} Input1 BitDPT.1CW
36Volume activation object J: {{0}} Input1 ByteDPT.5CW
37Scene chime interfaceInput1 ByteDPT.17CW
80E1 switching contact: {{0}}Output1 BitDPT.1CWT
80E1 alarm sensor : {{0}}Output1 BitDPT.1CWT
80E1 switching: {{0}}Output1 BitDPT.1CWT
80E1 blind UP/DOWN: {{0}}Output1 BitDPT.1CWT
80E1 switch (event 0): {{0}}Output1 BitDPT.1CT
80E1 priority (event 0): {{0}}Output2 BitDPT.2CT
80E1 1-byte value (-128 to 127) (event 0): {{0}}Output1 ByteDPT.6CT
80E1 1-byte value (0 to 255) (event 0): {{0}}Output1 ByteDPT.5CT
80E1 scene (event 0): {{0}}Output1 ByteDPT.18CT
80E1 2-byte value (-32,768 to 32,767) (event 0): {{0}}Output2 BytesDPT.8CT
80E1 2-byte value (0 to 65,535) (event 0): {{0}}Output2 BytesDPT.7CT
80E1 4-byte value (-2,147,483,648 to 2,147,483,647) (event 0): {{0}}Output4 BytesDPT.13CT
80E1 4-byte value (0 to 4294967295) (event 0): {{0}}Output4 BytesDPT.12CT
80E1 2-byte floating point (event 0): {{0}}Output2 BytesDPT.9CT
80E1 scene: {{0}}Output1 ByteDPT.18CWTU
80E1 switching step 1: {{0}}Output1 BitDPT.1CWT
80E1 switching 1 actuation: {{0}}Output1 BitDPT.1CWT
80E1 HZ: Counter reading 1-byte value: {{0}}Output1 ByteDPT.6CT
80E1 HZ: Counter reading 1-byte value: {{0}}Output1 ByteDPT.5CT
80E1 HZ: Counter reading 2-byte value: {{0}}Output2 BytesDPT.8CT
80E1 HZ: Counter reading 2-byte value: {{0}}Output2 BytesDPT.7CT
80E1 HZ: Counter reading 4-byte value: {{0}}Output4 BytesDPT.13CT
81E1 dimming: {{0}}Output4 BitDPT.3CT
81E1 STOP/slat adjustment: {{0}}Output1 BitDPT.1CT
81E1 switch (event 1): {{0}}Output1 BitDPT.1CT
81E1 priority (event 1): {{0}}Output2 BitDPT.2CT
81E1 1-byte value (-128 to 127) (event 1): {{0}}Output1 ByteDPT.6CT
81E1 1-byte value (0 to 255) (event 1): {{0}}Output1 ByteDPT.5CT
81E1 scene (event 1): {{0}}Output1 ByteDPT.18CT
81E1 2-byte value (-32,768 to 32,767) (event 1): {{0}}Output2 BytesDPT.8CT
81E1 2-byte value (0 to 65,535) (event 1): {{0}}Output2 BytesDPT.7CT
81E1 4-byte value (-2,147,483,648 to 2,147,483,647) (event 1): {{0}}Output4 BytesDPT.13CT
81E1 4-byte value (0 to 4294967295) (event 1): {{0}}Output4 BytesDPT.12CT
81E1 2-byte floating point (event 1): {{0}}Output2 BytesDPT.9CT
81E1 switching step 2: {{0}}Output1 BitDPT.1CWT
81E1 switching 2 actuations: {{0}}Output1 BitDPT.1CWT
81E1 ZZ: Counter reading 1-byte value: {{0}}Output1 ByteDPT.6CT
81E1 ZZ: Counter reading 1-byte value: {{0}}Output1 ByteDPT.5CT
81E1 ZZ: Counter reading 2-byte value: {{0}}Output2 BytesDPT.8CT
81E1 ZZ: Counter reading 2-byte value: {{0}}Output2 BytesDPT.7CT
81E1 ZZ: Counter reading 4-byte value: {{0}}Output4 BytesDPT.13CT
82E1 start event 0/1: {{0}}Input1 BitDPT.1CW
82E1 top end position: {{0}}Input1 BitDPT.1CW
82E1 scene storage display: {{0}}Output1 BitDPT.1CT
82E1 switching step 3: {{0}}Output1 BitDPT.1CWT
82E1 switching 3 actuations: {{0}}Output1 BitDPT.1CWT
82E1 HZ: Request counter reading: {{0}}Input1 BitDPT.1CW
83E1 bottom end position: {{0}}Input1 BitDPT.1CW
83E1 switching step 4: {{0}}Output1 BitDPT.1CWT
83E1 switching 4 actuations: {{0}}Output1 BitDPT.1CWT
83E1 HZ: Limit value exceeded: {{0}}Output1 BitDPT.1CT
84E1 save scene: {{0}}Input1 BitDPT.1CW
84E1 scene enable save: {{0}}Input1 BitDPT.1CW
84E1 switching step 5: {{0}}Output1 BitDPT.1CWT
84E1 switching, long actuation: {{0}}Output1 BitDPT.1CWT
85E1 switch step UP/DOWN: {{0}}Input1 BitDPT.1CW
85E1 ZZ: Limit value exceeded: {{0}}Output1 BitDPT.1CT
86E1 actuating number: {{0}}Input1 ByteDPT.5CWTU
86E1 ZZ: Request counter reading: {{0}}Input1 BitDPT.1CW
87E1 ZZ: Reverse direction: {{0}}Input1 BitDPT.1CW
88E1 ZZ: Reset: {{0}}Input1 BitDPT.1CW
89E1 ZZ: Stop: {{0}}Input1 BitDPT.1CW
98E1 blocking object: {{0}}Input1 BitDPT.1CW
98E1 blocking object: {{0}}Input1 BitDPT.1CW
Parameters (173)
ParameterTypeDefault
Send in operationlistinactive
PAR_DUMMYunsignedInt 0…2551
Cycle time in operationlistdisabled
Mute functionlistdisabled
PAR_DUMMY0unsignedInt 0…2551
Duration [s]unsignedInt 1…655351
Global blocking objectlistdisabled
Day-/ Night operationlistdisabled
DUMMY0unsignedInt 0…2551
Operation conditionlistday = '0' / night = '1'
Volume behaviourlistreduce
DUMMY1unsignedInt 0…2551
Reducelist1
DUMMY2unsignedInt 0…2551
Increaselist1
Day-/Night operation requestlistdisabled
Activate devicelistdisabled
DUMMY3unsignedInt 0…2551
DUMMY4unsignedInt 0…2551
DUMMY5unsignedInt 0…2551
Activation objectslistdisabled
Number of activation objectsunsignedInt 1…101
Descriptiontext
Activate conditionlistactive by '1'
Tone selectionlisttone 1 (alarm 1)
Volumelist5
Permanent activationlistdisabled
Number of cycles (1…100)unsignedInt 1…1001
Blocking objectlistdisabled
Volume adjustable by objectlistdisabled
Select activation objectlistA
Scene activationlistdisabled
PAR_TEXT_DUMMY5unsignedInt 0…2551
Number of scenesunsignedInt 1…161
Scene numberunsignedInt 1…641
Stop permanent device activationlistdisabled
DUMMY_0unsignedInt 0…2551
Scene numberunsignedInt 1…642
DUMMY_1unsignedInt 0…2551
Scene numberunsignedInt 1…643
DUMMY_2unsignedInt 0…2551
Scene numberunsignedInt 1…644
DUMMY_3unsignedInt 0…2551
Scene numberunsignedInt 1…645
DUMMY_4unsignedInt 0…2551
Scene numberunsignedInt 1…646
DUMMY_5unsignedInt 0…2551
Scene numberunsignedInt 1…647
DUMMY_6unsignedInt 0…2551
Scene numberunsignedInt 1…648
DUMMY_7unsignedInt 0…2551
Scene numberunsignedInt 1…649
DUMMY_8unsignedInt 0…2551
Scene numberunsignedInt 1…6410
DUMMY_9unsignedInt 0…2551
Scene numberunsignedInt 1…6411
DUMMY_10unsignedInt 0…2551
Scene numberunsignedInt 1…6412
DUMMY_11unsignedInt 0…2551
Scene numberunsignedInt 1…6413
DUMMY_12unsignedInt 0…2551
Scene numberunsignedInt 1…6414
DUMMY_13unsignedInt 0…2551
Scene numberunsignedInt 1…6415
DUMMY_14unsignedInt 0…2551
Scene numberunsignedInt 1…6416
DUMMY_15unsignedInt 0…2551
Limit number of telegramslistinactive
Maximum number of sent telegramsunsignedInt 1…25520
Maximum number of sent telegrams perlist1 second
Functionlistinactive
Binary functionlistSwitching/alarm
Switching/alarm contactlistswitch
communication object DPT 1.001text
communication object DPT 1.005text
Differentiation between short and long actuationlistinactive
contact opening -> event 0 contact closing -> event 1text
short actuation -> event 0 long actuation -> event 1text
long actuation from ... slist0,4
activate minimum signal durationlistinactive
at contact opening in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
at contact closing in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
query input after download, ETS reset and bus voltage recoverylistinactive
inactive waiting time after bus voltage recovery in s (0 - 30,000)unsignedInt 0…300000
input is being actuatedlistclosed
Enable object 'Start event 0/1'listinactive
Reaction at '1'listoff/alarm
Reaction at '1'liston/no alarm
Cyclical sendinglistinactive
telegram repeated every ... SunsignedInt 1…6553560
at object valueliston
Debouncing time ... mslist50
Enable object 'blocking object'listinactive
Switching/dimming contactlistdimmer/switch
Input is being actuatedlistclosed
Long actuation from ... slist0,4
At short actuation: switchinglistswitchover
At long actuation: dimming directionlistswitchover after switching darker
Dimming procedureliststart/stop
brightness change per sent telegramlist3,13%
telegram repeated every ... slist0,4
Blind operating functionlist1-push-button, short=slat, long=move
Brief actuation: STOP/stepwise Long actuation: move UP/DOWNtext
Short actuation: move UP/DOWN Long actuation: STOP/stepwisetext
One after another at actuation UP, STOP, DOWN, STOPtext
At actuation: move UP/DOWN STOP at end of actuationtext
Slat telegram repeated, every ... slist0,4
Determination short/long actuationlistinactive
Please note: open contact -> event 0 closed contact -> event 1text
Reaction at '1'list1-byte value (0 to 255)
sent valueliston
valuelist0
sent valuesignedInt -128…1270
sent valueunsignedInt 0…2550
sent valueunsignedInt 1…641
forced operationlistoff
sent valuesignedInt -32768…327670
sent valueunsignedInt 0…655350
sent valuesignedInt -2147483648…21474836470
sent valueunsignedInt 0…42949672950
sent valuefloat -670760.96…670433.2820
Reaction at '0'list1-byte value (0 to 255)
sent valuelistoff
sent valuefloat -670760.96…670433.28-20.00011
Enable object 'Blocking'listinactive
Scene number at actuationunsignedInt 1…641
Save scenelistno
long actuation from ... slist3
Number of stepslist3
Switching sequence typelistactivate/deactivate (one button)
Direction at actuationlistswitch up
Switching sequence like ...000>001>011>111>011>...text
Switching sequence like 000>001>011>111text
Switching sequence like ...000>001>011>010>110>...text
Activate minimum signal durationlistinactive
At contact opening in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
At contact closing in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
Max. number of actuationslist3
Sent valuelistswitchover
Update and send at actuationlistinactive
Maximum time between two actuations ... slist0,5
Additional object for long actuationlistinactive
sent value at long actuationlistswitchover
Data type (main counter)list4-byte value (-2,147,483,648 to 2,147,483,647)
communication object DPT 6.010text<---
communication object DPT 5.010text<---
communication object DPT 8.001text<---
communication object DPT 7.001text<---
communication object DPT 13.001text<---
Limit value 1signedInt -128…1270
Limit value 2signedInt -128…127127
Limit value 1unsignedInt 0…2550
Limit value 2unsignedInt 0…255255
Limit value 1signedInt -32768…327670
Limit value 2signedInt -32768…3276732767
Limit value 1unsignedInt 0…655350
Limit value 2unsignedInt 0…6553565535
Limit value 1signedInt -2147483648…21474836470
Limit value 2signedInt -2147483648…21474836472147483647
Counting typelistonly in case of rising edge
Number of input pulses for a counting pulseunsignedInt 1…100001
Counter reading change per counting pulsesignedInt -10000…100001
Send counter reading at download, ETS reset and bus voltage recoverylistinactive
Send counter reading at changelistinactive
counter reading is sent, everylistinactive
Save counter readinglistinactive
reset counter reading at downloadlistinactive
Enable intermediate counterlistinactive
Data type (intermediate counter)list4-byte value (-2,147,483,648 to 2,147,483,647)
Behaviour if a limit value is exceeded/undershotlistcontinue counting along perimeter
Reverse counting directionlistinactive
at contact opening in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510
at contact closing in value x 0.1 s (1 - 65,535)unsignedInt 1…6553510

Version history

ApplicationApp noFingerprintFirst seenSizeFile
AS 26.01 knx 1.0 latest$26016C312026-11-25144 KBDownload

About this file

This is the official ETS product database for the Hugo Müller GmbH & Co KG [AS 26.01 knx] Gong interface (AS 26.01 knx), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.