Honeywell MK Thermostats KNX BT TEMP
Honeywell Building Technologies · Order number KNX BT TEMP · Environment Sensors › Thermostats
Honeywell MK Thermostats
Download .knxprod KNX Thermostats 1.2 · 203 KB
Product
| Manufacturer | Honeywell Building Technologies |
|---|---|
| Product name | Honeywell MK Thermostats |
| Order number | KNX BT TEMP |
| Hardware | Honeywell MK Thermostats |
| Medium | Twisted Pair |
| Bus current (mA) | 4 |
| Rail mounted | No |
| Registration | Certified · 2022-03-25 |
| Languages | de-DE, en |
| Catalog entry | M-027D_H-KNXBTTEMP.5F090322-1-O0111_HP-2106-12-D060-O0111_CI-KNX.20BT.20TEMP-1 |
| Fingerprint | D060 |
| SHA-256 | 88ef340f631b8c5315071b8550ca67f438fa93c2796e57d4284d400397d98e81 |
| First seen | 2026-11-25 |
| Markets | 35 markets |
Application program: KNX Thermostats 1.2
| Application number | $2106 |
|---|---|
| Version | 1.2 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 525 |
| Group objects | 329 |
Group objects (329)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Button 1 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 0 | Button 1 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 0 | Button 1 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 1 | Button 1 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 1 | Button 1 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 1 | Button 1 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 2 | Button 1 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 3 | Button 1 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 4 | Button 1 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 5 | Button 1 | Scene Control | 1 Byte | CRTU | |
| 5 | Button 1 | HVAC Mode | 1 Byte | CRTU | |
| 5 | Button 1 | DHW Mode | 1 Byte | CRTU | |
| 6 | Button 1 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 6 | Button 1 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 7 | Button 1 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 8 | Button 1 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 9 | Button 1 | LED | 1 Bit | 1.1 switch | CWTU |
| 10 | Button 1 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 10 | Button 1 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 11 | Button 1 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 12 | Button 1 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 12 | Button 1 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 13 | Button 1 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 13 | Button 1 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 14 | Button 2 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 14 | Button 2 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 14 | Button 2 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 15 | Button 2 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 15 | Button 2 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 15 | Button 2 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 16 | Button 2 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 17 | Button 2 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 18 | Button 2 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 19 | Button 2 | Scene Control | 1 Byte | CRTU | |
| 19 | Button 2 | HVAC Mode | 1 Byte | CRTU | |
| 19 | Button 2 | DHW Mode | 1 Byte | CRTU | |
| 20 | Button 2 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 20 | Button 2 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 21 | Button 2 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 22 | Button 2 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 23 | Button 2 | LED | 1 Bit | 1.1 switch | CWTU |
| 24 | Button 2 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 24 | Button 2 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 25 | Button 2 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 26 | Button 2 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 26 | Button 2 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 27 | Button 2 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 27 | Button 2 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 28 | Button 3 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 28 | Button 3 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 28 | Button 3 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 29 | Button 3 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 29 | Button 3 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 29 | Button 3 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 30 | Button 3 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 31 | Button 3 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 32 | Button 3 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 33 | Button 3 | Scene Control | 1 Byte | CRTU | |
| 33 | Button 3 | HVAC Mode | 1 Byte | CRTU | |
| 33 | Button 3 | DHW Mode | 1 Byte | CRTU | |
| 34 | Button 3 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 34 | Button 3 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 35 | Button 3 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 36 | Button 3 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 37 | Button 3 | LED | 1 Bit | 1.1 switch | CWTU |
| 38 | Button 3 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 38 | Button 3 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 39 | Button 3 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 40 | Button 3 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 40 | Button 3 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 41 | Button 3 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 41 | Button 3 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 42 | Button 4 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 42 | Button 4 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 42 | Button 4 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 43 | Button 4 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 43 | Button 4 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 43 | Button 4 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 44 | Button 4 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 45 | Button 4 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 46 | Button 4 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 47 | Button 4 | Scene Control | 1 Byte | CRTU | |
| 47 | Button 4 | HVAC Mode | 1 Byte | CRTU | |
| 47 | Button 4 | DHW Mode | 1 Byte | CRTU | |
| 48 | Button 4 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 48 | Button 4 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 49 | Button 4 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 50 | Button 4 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 51 | Button 4 | LED | 1 Bit | 1.1 switch | CWTU |
| 52 | Button 4 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 52 | Button 4 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 53 | Button 4 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 54 | Button 4 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 54 | Button 4 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 55 | Button 4 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 55 | Button 4 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 56 | Button 5 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 56 | Button 5 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 56 | Button 5 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 57 | Button 5 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 57 | Button 5 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 57 | Button 5 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 58 | Button 5 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 59 | Button 5 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 60 | Button 5 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 61 | Button 5 | Scene Control | 1 Byte | CRTU | |
| 61 | Button 5 | HVAC Mode | 1 Byte | CRTU | |
| 61 | Button 5 | DHW Mode | 1 Byte | CRTU | |
| 62 | Button 5 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 62 | Button 5 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 63 | Button 5 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 64 | Button 5 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 65 | Button 5 | LED | 1 Bit | 1.1 switch | CWTU |
| 66 | Button 5 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 66 | Button 5 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 67 | Button 5 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 68 | Button 5 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 68 | Button 5 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 69 | Button 5 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 69 | Button 5 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 70 | Button 6 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 70 | Button 6 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 70 | Button 6 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 71 | Button 6 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 71 | Button 6 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 71 | Button 6 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 72 | Button 6 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 73 | Button 6 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 74 | Button 6 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 75 | Button 6 | Scene Control | 1 Byte | CRTU | |
| 75 | Button 6 | HVAC Mode | 1 Byte | CRTU | |
| 75 | Button 6 | DHW Mode | 1 Byte | CRTU | |
| 76 | Button 6 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 76 | Button 6 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 77 | Button 6 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 78 | Button 6 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 79 | Button 6 | LED | 1 Bit | 1.1 switch | CWTU |
| 80 | Button 6 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 80 | Button 6 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 81 | Button 6 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 82 | Button 6 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 82 | Button 6 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 83 | Button 6 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 83 | Button 6 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 84 | Logic A | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 84 | Logic A | Input DPT1 (1 bit) | 1 Bit | 1.1 switch | CWTU |
| 84 | Logic A | Input 1 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 85 | Logic A | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 85 | Logic A | Input 2 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 86 | Logic A | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 86 | Logic A | Input 3 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 87 | Logic A | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 87 | Logic A | Input 4 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 88 | Logic A | Input DPT2 (2 bit) | 2 Bit | DPT.2 | CWTU |
| 89 | Logic A | Input DPT3 (4 bit) | 4 Bit | DPT.3 | CWTU |
| 90 | Logic A | Input DPT4/5/6 (1 byte) | 1 Byte | DPT.4 | CWTU |
| 91 | Logic A | Input DPT7/8/9 (2 byte) | 2 Bytes | DPT.7 | CWTU |
| 92 | Logic A | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 92 | Logic A | Output DPT1 (1 bit) | 1 Bit | 1.1 switch | CRTU |
| 93 | Logic A | Output DPT2 (2 bit) | 2 Bit | DPT.2 | CRTU |
| 94 | Logic A | Output DPT3 (4 bit) | 4 Bit | DPT.3 | CRTU |
| 95 | Logic A | Scene | 1 Byte | DPT.4 | CRTU |
| 95 | Logic A | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 95 | Logic A | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 95 | Logic A | Output DPT4/5/6 (1 byte) | 1 Byte | DPT.4 | CRTU |
| 96 | Logic A | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 96 | Logic A | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 96 | Logic A | Output DPT7/8/9 (2 byte) | 2 Bytes | DPT.7 | CRTU |
| 97 | Logic A | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 97 | Logic A | Copy Disable (if 1) | 1 Bit | 1.2 boolean | CRWU |
| 97 | Logic A | Copy Disable (if 0) | 1 Bit | 1.2 boolean | CRWU |
| 98 | Logic B | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 98 | Logic B | Input DPT1 (1 bit) | 1 Bit | 1.1 switch | CWTU |
| 98 | Logic B | Input 1 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 99 | Logic B | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 99 | Logic B | Input 2 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 100 | Logic B | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 100 | Logic B | Input 3 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 101 | Logic B | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 101 | Logic B | Input 4 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 102 | Logic B | Input DPT2 (2 bit) | 2 Bit | DPT.2 | CWTU |
| 103 | Logic B | Input DPT3 (4 bit) | 4 Bit | DPT.3 | CWTU |
| 104 | Logic B | Input DPT4/5/6 (1 byte) | 1 Byte | DPT.4 | CWTU |
| 105 | Logic B | Input DPT7/8/9 (2 byte) | 2 Bytes | DPT.7 | CWTU |
| 106 | Logic B | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 106 | Logic B | Output DPT1 (1 bit) | 1 Bit | 1.1 switch | CRTU |
| 107 | Logic B | Output DPT2 (2 bit) | 2 Bit | DPT.2 | CRTU |
| 108 | Logic B | Output DPT3 (4 bit) | 4 Bit | DPT.3 | CRTU |
| 109 | Logic B | Scene | 1 Byte | DPT.4 | CRTU |
| 109 | Logic B | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 109 | Logic B | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 109 | Logic B | Output DPT4/5/6 (1 byte) | 1 Byte | DPT.4 | CRTU |
| 110 | Logic B | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 110 | Logic B | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 110 | Logic B | Output DPT7/8/9 (2 byte) | 2 Bytes | DPT.7 | CRTU |
| 111 | Logic B | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 111 | Logic B | Copy Disable (if 1) | 1 Bit | 1.2 boolean | CRWU |
| 111 | Logic B | Copy Disable (if 0) | 1 Bit | 1.2 boolean | CRWU |
| 112 | Logic C | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 112 | Logic C | Input DPT1 (1 bit) | 1 Bit | 1.1 switch | CWTU |
| 112 | Logic C | Input 1 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 113 | Logic C | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 113 | Logic C | Input 2 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 114 | Logic C | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 114 | Logic C | Input 3 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 115 | Logic C | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 115 | Logic C | Input 4 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 116 | Logic C | Input DPT2 (2 bit) | 2 Bit | DPT.2 | CWTU |
| 117 | Logic C | Input DPT3 (4 bit) | 4 Bit | DPT.3 | CWTU |
| 118 | Logic C | Input DPT4/5/6 (1 byte) | 1 Byte | DPT.4 | CWTU |
| 119 | Logic C | Input DPT7/8/9 (2 byte) | 2 Bytes | DPT.7 | CWTU |
| 120 | Logic C | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 120 | Logic C | Output DPT1 (1 bit) | 1 Bit | 1.1 switch | CRTU |
| 121 | Logic C | Output DPT2 (2 bit) | 2 Bit | DPT.2 | CRTU |
| 122 | Logic C | Output DPT3 (4 bit) | 4 Bit | DPT.3 | CRTU |
| 123 | Logic C | Scene | 1 Byte | DPT.4 | CRTU |
| 123 | Logic C | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 123 | Logic C | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 123 | Logic C | Output DPT4/5/6 (1 byte) | 1 Byte | DPT.4 | CRTU |
| 124 | Logic C | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 124 | Logic C | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 124 | Logic C | Output DPT7/8/9 (2 byte) | 2 Bytes | DPT.7 | CRTU |
| 125 | Logic C | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 125 | Logic C | Copy Disable (if 1) | 1 Bit | 1.2 boolean | CRWU |
| 125 | Logic C | Copy Disable (if 0) | 1 Bit | 1.2 boolean | CRWU |
| 126 | Logic D | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 126 | Logic D | Input DPT1 (1 bit) | 1 Bit | 1.1 switch | CWTU |
| 126 | Logic D | Input 1 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 127 | Logic D | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 127 | Logic D | Input 2 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 128 | Logic D | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 128 | Logic D | Input 3 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 129 | Logic D | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 129 | Logic D | Input 4 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 130 | Logic D | Input DPT2 (2 bit) | 2 Bit | DPT.2 | CWTU |
| 131 | Logic D | Input DPT3 (4 bit) | 4 Bit | DPT.3 | CWTU |
| 132 | Logic D | Input DPT4/5/6 (1 byte) | 1 Byte | DPT.4 | CWTU |
| 133 | Logic D | Input DPT7/8/9 (2 byte) | 2 Bytes | DPT.7 | CWTU |
| 134 | Logic D | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 134 | Logic D | Output DPT1 (1 bit) | 1 Bit | 1.1 switch | CRTU |
| 135 | Logic D | Output DPT2 (2 bit) | 2 Bit | DPT.2 | CRTU |
| 136 | Logic D | Output DPT3 (4 bit) | 4 Bit | DPT.3 | CRTU |
| 137 | Logic D | Scene | 1 Byte | DPT.4 | CRTU |
| 137 | Logic D | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 137 | Logic D | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 137 | Logic D | Output DPT4/5/6 (1 byte) | 1 Byte | DPT.4 | CRTU |
| 138 | Logic D | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 138 | Logic D | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 138 | Logic D | Output DPT7/8/9 (2 byte) | 2 Bytes | DPT.7 | CRTU |
| 139 | Logic D | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 139 | Logic D | Copy Disable (if 1) | 1 Bit | 1.2 boolean | CRWU |
| 139 | Logic D | Copy Disable (if 0) | 1 Bit | 1.2 boolean | CRWU |
| 140 | LCD BackLight | Force OFF (if '1') | 1 Bit | 1.2 boolean | CWTU |
| 140 | LCD BackLight | Force OFF (if '0') | 1 Bit | 1.2 boolean | CWTU |
| 141 | LCD BackLight | LCD Brightness (%) | 1 Byte | 5.1 percentage (0..100%) | CRWTU |
| 142 | Thermostat | LED Button + | 1 Bit | 1.2 boolean | CWTU |
| 143 | Thermostat | LED Button - | 1 Bit | 1.2 boolean | CWTU |
| 144 | Thermostat | Temperature Indication | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 145 | Thermostat | Temperature (external source) | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 146 | Thermostat | Heating / Cooling Indication | 1 Bit | DPT.1 | CRTU |
| 147 | Thermostat | Heating / Cooling | 1 Bit | DPT.1 | CWTU |
| 148 | Thermostat | Comfort Mode Trigger | 1 Bit | DPT.1 | CWTU |
| 149 | Thermostat | StandBy Mode Trigger | 1 Bit | DPT.1 | CWTU |
| 150 | Thermostat | Economy Mode Trigger | 1 Bit | DPT.1 | CWTU |
| 151 | Thermostat | Building Protection Trigger | 1 Bit | DPT.1 | CWTU |
| 152 | Thermostat | Mode (next/previous) | 1 Bit | 1.8 up/down | CWTU |
| 153 | Thermostat | Mode Indication | 1 Byte | CRTU | |
| 154 | Thermostat | Comfort Mode Ind. | 1 Bit | 1.3 enable | CRTU |
| 155 | Thermostat | StandBy Mode Ind. | 1 Bit | 1.3 enable | CRTU |
| 156 | Thermostat | Economy Mode Ind. | 1 Bit | 1.3 enable | CRTU |
| 157 | Thermostat | Building Protection Ind. | 1 Bit | 1.3 enable | CRTU |
| 158 | Thermostat | Mode | 1 Byte | CWTU | |
| 159 | Thermostat | Force Mode | 1 Byte | CWTU | |
| 160 | Thermostat | Time Limited Comfort | 1 Bit | DPT.1 | CWTU |
| 161 | Thermostat | Presence Detector Input | 1 Bit | 1.2 boolean | CWTU |
| 162 | Thermostat | Forced Building Protection | 1 Bit | 1.2 boolean | CWTU |
| 163 | Thermostat | Window Status | 1 Bit | 1.9 open/close | CWTU |
| 164 | Thermostat | Current Setpoint Temp. Ind. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 165 | Thermostat | Current Setpoint Temperature | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 166 | Thermostat | Current Setpoint Temp. Step | 1 Bit | 1.8 up/down | CWTU |
| 167 | Thermostat | Heating Setpoint Temp. Ind. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 168 | Thermostat | Cooling Setpoint Temp. Ind. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 169 | Thermostat | Outdoor Temperature Input | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 170 | Thermostat | Spot Temperature (Heating) | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 171 | Thermostat | Spot Temperature (Cooling) | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 172 | Thermostat | Internal Sensor Value Ind. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 173 | Thermostat | Scene | 1 Byte | CWTU | |
| 174 | Thermostat | Controller Status Indication | 2 Bytes | CRTU | |
| 175 | Thermostat | Controller Status Ind. (leg) | 1 Byte | CRTU | |
| 176 | Thermostat | Jamming | 1 Bit | 1.3 enable | CWTU |
| 177 | Thermostat | Frost Alarm Indication | 1 Bit | 1.2 boolean | CRTU |
| 178 | Thermostat | Heat Alarm Indication | 1 Bit | 1.2 boolean | CRTU |
| 179 | Thermostat | Base Temperature Indication | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 180 | Thermostat | Base Temperature | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 181 | Thermostat | Base Temperature Step | 1 Bit | DPT.1 | CWTU |
| 182 | Heater | Stop | 1 Bit | 1.2 boolean | CWTU |
| 182 | Comb. (Heat/Cool) | Stop | 1 Bit | 1.2 boolean | CWTU |
| 183 | Heater | Heater control | 1 Bit | 1.1 switch | CRTU |
| 183 | Comb. (Heat/Cool) | Comb. control | 1 Bit | 1.1 switch | CRTU |
| 184 | Heater | Heater control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 184 | Comb. (Heat/Cool) | Comb. Control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 185 | Heater | Fan Speed 1 | 1 Bit | 1.1 switch | CRTU |
| 185 | Comb. (Heat/Cool) | Fan Speed 1 | 1 Bit | 1.1 switch | CRTU |
| 186 | Heater | Fan Speed 2 | 1 Bit | 1.1 switch | CRTU |
| 186 | Comb. (Heat/Cool) | Fan Speed 2 | 1 Bit | 1.1 switch | CRTU |
| 187 | Heater | Fan Speed 3 | 1 Bit | 1.1 switch | CRTU |
| 187 | Comb. (Heat/Cool) | Fan Speed 3 | 1 Bit | 1.1 switch | CRTU |
| 188 | Heater | Fan Speed (%) | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 188 | Comb. (Heat/Cool) | Fan Speed (%) | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 189 | Supp. Heater | Stop | 1 Bit | 1.2 boolean | CWTU |
| 189 | Supp. Comb. | Stop | 1 Bit | 1.2 boolean | CWTU |
| 190 | Supp. Heater | Supplementary Heater control | 1 Bit | 1.1 switch | CRTU |
| 190 | Supp. Comb. | Supplementary Comb. control | 1 Bit | 1.1 switch | CRTU |
| 191 | Supp. Heater | Supplementary Heater control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 191 | Supp. Comb. | Supplementary Comb. control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 192 | Cooler | Stop | 1 Bit | 1.2 boolean | CWTU |
| 193 | Cooler | Cooler Control | 1 Bit | 1.1 switch | CRTU |
| 194 | Cooler | Cooler Control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 195 | Cooler | Fan Speed 1 | 1 Bit | 1.1 switch | CRTU |
| 196 | Cooler | Fan Speed 2 | 1 Bit | 1.1 switch | CRTU |
| 197 | Cooler | Fan Speed 3 | 1 Bit | 1.1 switch | CRTU |
| 198 | Cooler | Fan Speed (%) | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 199 | Supp. Cooler | Stop | 1 Bit | 1.2 boolean | CWTU |
| 200 | Supp. Cooler | Supplementary Cooler control | 1 Bit | 1.1 switch | CRTU |
| 201 | Supp. Cooler | Supplementary Cooler control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 202 | Fan Control | Enable Auto. 0-Man/1-Auto | 1 Bit | 1.2 boolean | CWTU |
| 203 | Fan Control | Speed Step | 1 Bit | DPT.1 | CWTU |
| 204 | Fan Control | Set Speed (%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 205 | Fan Control | Auto. 0-Man/1-Auto indication | 1 Bit | 1.2 boolean | CRTU |
Parameters (229)
| Parameter | Type | Default |
|---|---|---|
| Duration of long key press for Dimming and Shutter/Blinds operation (ms) | unsignedInt 0…12500 | 500 |
| Duration of long key press for 2-Channel mode operation (ms) | unsignedInt 0…12500 | 1000 |
| Duration of LED key press confirmation (s) | unsignedInt 0…65535 | 5 |
| Application Version | text | V0.0.1 |
| Function | list | Button not used |
| Press / Release | list | 0 |
| None | unsignedInt 0…0 | 0 |
| Press / Release | list | Toggle / - |
| 1 button dimming | unsignedInt 0…255 | 11 |
| Mode | list | 1 Button Dimmer |
| Direction | list | Increase |
| Mode | list | 1 Button Shutter/Blinds |
| 1 button | unsignedInt 0…255 | 14 |
| Direction | list | Up |
| Value | list | Auto |
| Scene Number | list | Scene 1 |
| Mode | list | Send Scene |
| Value Type | list | Percentage |
| Luminosity (lux) | list | 0 lux |
| Temperature | list | 0 °C |
| Channel A (Short) / Channel B (Long) | list | Toggle / Toggle |
| LED Usage | list | OFF |
| Jamming | list | Not used |
| Emission Delay (s) | unsignedInt 0…65535 | 0 |
| Mode | list | 1 channel mode |
| Value | list | Priority OFF |
| Short Press / Long Press | list | OFF / Prio. OFF |
| Percentage (%) | list | 0.0% | 0x00 |
| Angle (°) | list | 00.00 ° | 0x00 |
| Mode | list | Send Value |
| Emission delay cancellable by second press? | list | No |
| Behavior at Power up | list | Don't read objects |
| Function | list | Switch (ON/OFF) |
| none | unsignedInt 0…0 | 0 |
| scene | unsignedInt 26…26 | 26 |
| Logic Channel A | list | Not used |
| Logic Operation | list | And |
| Input 1 | list | Disabled |
| Input 2 | list | Disabled |
| Input 3 | list | Disabled |
| Input 4 | list | Disabled |
| func onoff | unsignedInt 1…1 | 1 |
| Send Condition | list | When result changes |
| Debounce Time (s) | unsignedInt 0…255 | 0 |
| Backlight Mode | list | Not used |
| Copy and forward an object | unsignedInt 53…53 | 53 |
| DPT1 Copy | list | Not used |
| DPT2 Copy | list | Not used |
| DPT3 Copy | list | Not used |
| DPT4/5/6 Copy | list | Not used |
| DPT7/8/9 Copy | list | Not used |
| Disable copy | list | Not used |
| Emission Delay (s) (Attention: See the product manual) | unsignedInt 0…65535 | 0 |
| Logic Channel B | list | Not used |
| Logic Channel C | list | Not used |
| Logic Channel D | list | Not used |
| Heating Type | list | HVAC |
| Initial Result Status | list | FALSE |
| Apply jamming to | list | Jamming Output |
| Dimming Step | list | 100% |
| Repetition Period | list | Don't Repeat |
| When Copy Re-enabled | list | Do nothing |
| PID_HardwareType | list | HARDWARE_TYPE |
| HVAC installation type | list | Heating |
| Changeover Cooling/Heating | list | Automatic |
| Temperatures to show | list | Room -> Setpoint |
| Update rate (s) | unsignedInt 0…255 | 0 |
| The source of the Room temperature | list | Internal Sensor |
| Make Read Request to external source? | list | No |
| Use valve protection? | list | No |
| Aperture angle to open and close(º) | unsignedInt 1…15 | 5 |
| Time of inactivity before open and close | list | approx. 12 hours |
| Modification via push buttons +/- | list | Permanent change of setpoint |
| Internal sensor calibration (10 = 1°C) | signedInt -100…100 | 0 |
| Time Limited Comfort Usage | list | 1 h |
| Send Thermostat's Status COs every (min) (0 = never send) | unsignedInt 0…255 | 0 |
| Temperature Increase for Economy mode | list | 2.0 °C |
| Temperature Increase for Standby | list | 4.0 °C |
| Bluiding Heating protection temperature | list | 37.0 °C |
| Bluiding Frost protection temperature | list | 3.0 °C |
| Temperature Decrease for Standby | list | 4.0 °C |
| Temperature Decrease for Economy mode | list | 2.0 °C |
| Controller type | list | ON-OFF controller |
| Use cooling supplementary system | list | No |
| Use heating supplementary system | list | No |
| Supplementary controller type | list | ON-OFF controller |
| Supplementary control type | list | ON-OFF controller |
| Difference between "main" and "supplementary" setpoint | list | 2.0 °C |
| Proportional band / Gain (Kp) (1%/1°C) | unsignedInt 0…255 | 20 |
| Integration time (Ti) (minutes) | unsignedInt 0…255 | 100 |
| Derivative time (Td) (minutes) | unsignedInt 0…255 | 0 |
| Use outdoor temperature for limiting used power? | list | No |
| Use spot limit temperature? | list | No |
| Delta set (°C) | list | 2.0 °C |
| Fluctuation range (°C) | list | 25.0 °C |
| Spot's minimum temperature | list | 10.0 °C |
| Spot's maximum temperature | list | 35.0 °C |
| Fan usage on cooling | list | Automatic |
| Fan usage on heating | list | Automatic |
| Use fan protection? | list | No |
| Duration of fan in max speed (s) | unsignedInt 1…15 | 3 |
| Time of inactivity before starting and stopping the fan | list | approx. 1 day |
| Mode for scene 1 | list | Don't react |
| Mode for scene 2 | list | Don't react |
| Mode for scene 3 | list | Don't react |
| Mode for scene 5 | list | Don't react |
| Mode for scene 4 | list | Don't react |
| Mode for scene 6 | list | Don't react |
| Mode for scene 7 | list | Don't react |
| Mode for scene 8 | list | Don't react |
| Mode for scene 9 | list | Don't react |
| Mode for scene 10 | list | Don't react |
| Mode for scene 11 | list | Don't react |
| Mode for scene 12 | list | Don't react |
| Mode for scene 13 | list | Don't react |
| Mode for scene 14 | list | Don't react |
| Mode for scene 15 | list | Don't react |
| Mode for scene 16 | list | Don't react |
| Mode for scene 17 | list | Don't react |
| Mode for scene 18 | list | Don't react |
| Mode for scene 19 | list | Don't react |
| Mode for scene 20 | list | Don't react |
| Mode for scene 21 | list | Don't react |
| Mode for scene 22 | list | Don't react |
| Mode for scene 23 | list | Don't react |
| Mode for scene 24 | list | Don't react |
| Mode for scene 25 | list | Don't react |
| Mode for scene 26 | list | Don't react |
| Mode for scene 27 | list | Don't react |
| Mode for scene 28 | list | Don't react |
| Mode for scene 29 | list | Don't react |
| Mode for scene 30 | list | Don't react |
| Mode for scene 31 | list | Don't react |
| Mode for scene 32 | list | Don't react |
| Mode for scene 33 | list | Don't react |
| Mode for scene 34 | list | Don't react |
| Mode for scene 35 | list | Don't react |
| Mode for scene 36 | list | Don't react |
| Mode for scene 37 | list | Don't react |
| Mode for scene 38 | list | Don't react |
| Mode for scene 39 | list | Don't react |
| Mode for scene 40 | list | Don't react |
| Mode for scene 41 | list | Don't react |
| Mode for scene 42 | list | Don't react |
| Mode for scene 43 | list | Don't react |
| Mode for scene 44 | list | Don't react |
| Mode for scene 45 | list | Don't react |
| Mode for scene 46 | list | Don't react |
| Mode for scene 47 | list | Don't react |
| Mode for scene 48 | list | Don't react |
| Mode for scene 49 | list | Don't react |
| Mode for scene 50 | list | Don't react |
| Mode for scene 51 | list | Don't react |
| Mode for scene 52 | list | Don't react |
| Mode for scene 53 | list | Don't react |
| Mode for scene 54 | list | Don't react |
| Mode for scene 55 | list | Don't react |
| Mode for scene 56 | list | Don't react |
| Mode for scene 57 | list | Don't react |
| Mode for scene 58 | list | Don't react |
| Mode for scene 59 | list | Don't react |
| Mode for scene 60 | list | Don't react |
| Mode for scene 61 | list | Don't react |
| Mode for scene 62 | list | Don't react |
| Mode for scene 63 | list | Don't react |
| Mode for scene 64 | list | Don't react |
| Allow to save scenes via "learn scene" request? | list | No |
| Distance between decision levels (10 = 1°C) | unsignedInt 0…255 | 30 |
| Initial operating mode | list | Wait for bus response |
| Hysteresis (10 = 1°C) | unsignedInt 1…255 | 5 |
| Hysteresis (10 = 1°C) | unsignedInt 1…255 | 10 |
| Threshold to set from Off to Speed 1 (10=1°C) | unsignedInt 0…100 | 1 |
| Threshold to set from Speed 1 to 2 (10=1°C) | unsignedInt 0…100 | 30 |
| Threshold to set from Speed 2 to 3 (10=1°C) | unsignedInt 0…100 | 60 |
| Hysteresis between threshold values (10=1°C) | unsignedInt 0…100 | 5 |
| Threshold to set from Off to Speed 1 (%) | unsignedInt 0…100 | 1 |
| Threshold to set from Speed 1 to 2 (%) | unsignedInt 0…100 | 30 |
| Threshold to set from Speed 2 to 3 (%) | unsignedInt 0…100 | 60 |
| Hysteresis between threshold values (%) | unsignedInt 0…100 | 5 |
| Time between speed switch (10 = 1s) | unsignedInt 0…255 | 10 |
| Maximum deviation (+/-°C) | unsignedInt 0…15 | 3 |
| Modification via CO | list | Permanent change of setpoint |
| Emission of control value | list | approx. 1% |
| Controller execution period | list | 30 sec |
| Setpoint Temperature | list | 24.0 °C |
| Switchover trigger | list | Room Temperature |
| Enter Cooling when outdoor is | list | 28.0 °C |
| Enter Heating when outdoor is | list | 14.0 °C |
| Over-Heat Alarm Temperature | list | 40.0 °C |
| Frost Alarm Temperature | list | 0 °C |
| SET_NEW_PARAMS_FLAGS | list | SET_ALL_NEW |
| Display on LCD | list | Display in sequence |
| Th_display_measure | unsignedInt 0…255 | 1 |
| Th_display_measure | unsignedInt 0…255 | 2 |
| Th_display_measure | unsignedInt 0…255 | 4 |
| LCD Brightness | list | 100% |
| Use LCD Backlight Sleep? | list | Yes |
| Bright reduction during "Sleep" | list | 80% |
| Inactivity time to "Sleep" | unsignedInt 10…240 | 15 |
| INVISIBLE: marks auto sleep as not used | unsignedInt 0…255 | 9 |
| LEDs +/- usage | list | Signalize controller activity |
| LED - CO Link type | list | Linked w/ CO (On if '1') |
| LED + CO Link type | list | Linked w/ CO (On if '1') |
| LED + status | list | LED allways Off |
| LED - status | list | LED allways Off |
| SETS LEDS +- TO SIGNALIZE CONTROLLER ACT | unsignedInt 0…255 | 34 |
| Allow Fan's Man. control when available? | list | Don't allow |
| Manual Fan Control step value | list | 33.7% | 0x56 (3 Speed Fan) |
| Manual Fan Controll step rollover allowed (at upper/lower limit)? | list | Not allowed |
| Use time limited Comfort mode | list | No |
| _Th_TimeLimitedComfortUsage:NOT_USED | unsignedInt 0…255 | 0 |
| Use Over-Heat and Freeze alarms? | list | No |
| Use 1bit Enable CO per Mode? | list | Yes |
| Use Next/Prev Mode CO (1bit)? | list | No |
| Use HVAC Mode CO (1byte)? | list | Yes |
| Use Presence Detector? | list | No |
| Use 'Force Building Protection' Comm. Obj.? | list | No |
| Use 'Window Status' Com. Obj.? | list | No |
| Use fan in cooling | list | No |
| Th_AC_FanUsage:NOT_USED | unsignedInt 0…255 | 0 |
| Use fan in heating | list | No |
| Th_FanUsage:NOT_USED | unsignedInt 0…255 | 0 |
| Th_FrostAlarm:NOT_USED | unsignedInt 0…65535 | 0 |
| Th_FrostAlarm:NOT_USED | unsignedInt 0…65535 | 5221 |
| Th_tempsTime2Disp:FIXED | unsignedInt 0…255 | 3 |
| Messages to block | list | Block Sending |
| After Jamming | list | Do nothing |
| Th_AC_Heat_swov_NONE | unsignedInt 0…3 | 0 |
| Send temperature value when changes more than (10=1°C; 0->never) | unsignedInt 0…50 | 5 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Thermostats 1.2 latest | $2106 | D060 | 2026-11-25 | 203 KB | Download |
About this file
This is the official ETS product database for the Honeywell Building Technologies Honeywell MK Thermostats (KNX BT TEMP), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Honeywell Building Technologies
- Honeywell MK HVAC Module HKLS-FCU
- Honeywell KNX IP54 Microwave Sensor HNX MWV30IP54
- Honeywell KNX Surface PIR Sensor 24D Coverage HNX PIR 24D
- Honeywell KNX Thermostat 6Fold HNX TSTAT xx
- Honeywell KNX Carbon Dioxide Sensor KNX CO2 SENSOR
- Honeywell MK Dimmer 4CH 1.5A 300W KNX DIM 4CH 300W
- Honeywell MK DIM 6CH 0-10V KNX DIM 6CH 0-10V
- Honeywell KNX Microwave sensor KNX MWV FL
- Honeywell MK PIR Sensor KNX PIR Sensor
- Honeywell MK Timer KNX Timer
- Honeywell MK 24-Zone Dry Contact Module HKLS-IO24
- Honeywell KNX Line Coupler Secure HNX LN CPL SEC