Honeywell KNX Carbon Dioxide Sensor KNX CO2 SENSOR
Honeywell Building Technologies · Order number KNX CO2 SENSOR · Environment Sensors › Thermostats
Download .knxprod KNX Carbon Dioxide Sensor 1.0 · 177 KB
Product
| Manufacturer | Honeywell Building Technologies |
|---|---|
| Product name | Honeywell KNX Carbon Dioxide Sensor |
| Order number | KNX CO2 SENSOR |
| Hardware | Honeywell KNX Carbon Dioxide Sensor |
| Medium | Twisted Pair |
| Bus current (mA) | 17 |
| Rail mounted | No |
| Registration | Certified · 2025-04-22 |
| Languages | en-US |
| Catalog entry | M-027D_H-CH23EA-1-O0085_HP-4103-10-4918-O0085_CI-KNX.20CO2.20SENSOR-1 |
| Fingerprint | 4918 |
| SHA-256 | 1f7bba39b18d38f1316e277f9c5109140376af0c7353c08285cce4f62f8685df |
| First seen | 2026-11-25 |
| Markets | 31 markets |
Application program: KNX Carbon Dioxide Sensor 1.0
| Application number | $4103 |
|---|---|
| Version | 1.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 386 |
| Group objects | 231 |
Group objects (231)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | RTC 1 - {{0:...}} | Power on/off | 1 Bit | 1.1 switch | CRW |
| 0 | RTC 2 - {{0:...}} | Power on/off | 1 Bit | 1.1 switch | CRW |
| 0 | RTC 3 - {{0:...}} | Power on/off | 1 Bit | 1.1 switch | CRW |
| 1 | General | In operation | 1 Bit | 1.1 switch | CRT |
| 1 | RTC 1 - {{0:...}} | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | RTC 2 - {{0:...}} | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | RTC 3 - {{0:...}} | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 2 | General | Alarm input | 1 Bit | 1.5 alarm | CWTU |
| 2 | RTC 1 - {{0:...}} | Base setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 1 - {{0:...}} | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 2 - {{0:...}} | Base setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 2 - {{0:...}} | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 3 - {{0:...}} | Base setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 3 - {{0:...}} | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 3 | General | Alarm acknowledge | 1 Bit | 1.16 acknowledge | CW |
| 3 | RTC 1 - {{0:...}} | Setpoint offset | 1 Bit | 1.7 step | CW |
| 3 | RTC 2 - {{0:...}} | Setpoint offset | 1 Bit | 1.7 step | CW |
| 3 | RTC 3 - {{0:...}} | Setpoint offset | 1 Bit | 1.7 step | CW |
| 4 | RTC 1 - {{0:...}} | Float offset value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 4 | RTC 2 - {{0:...}} | Float offset value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 4 | RTC 3 - {{0:...}} | Float offset value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 5 | Internal sensor | Temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 5 | RTC 1 - {{0:...}} | Setpoint offset reset | 1 Bit | 1.15 reset | CW |
| 5 | RTC 2 - {{0:...}} | Setpoint offset reset | 1 Bit | 1.15 reset | CW |
| 5 | RTC 3 - {{0:...}} | Setpoint offset reset | 1 Bit | 1.15 reset | CW |
| 6 | Internal sensor | Low temperature alarm | 1 Bit | 1.5 alarm | CRT |
| 6 | RTC 1 - {{0:...}} | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CW |
| 6 | RTC 2 - {{0:...}} | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CW |
| 6 | RTC 3 - {{0:...}} | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CW |
| 7 | Internal sensor | High temperature alarm | 1 Bit | 1.5 alarm | CRT |
| 7 | RTC 1 - {{0:...}} | Operation mode | 1 Byte | 20.102 HVAC mode | CW |
| 7 | RTC 2 - {{0:...}} | Operation mode | 1 Byte | 20.102 HVAC mode | CW |
| 7 | RTC 3 - {{0:...}} | Operation mode | 1 Byte | 20.102 HVAC mode | CW |
| 8 | Internal sensor | Humidity value | 2 Bytes | 9.7 humidity (%) | CRT |
| 8 | RTC 1 - {{0:...}} | Comfort mode | 1 Bit | 1.3 enable | CW |
| 8 | RTC 2 - {{0:...}} | Comfort mode | 1 Bit | 1.3 enable | CW |
| 8 | RTC 3 - {{0:...}} | Comfort mode | 1 Bit | 1.3 enable | CW |
| 9 | Internal sensor | Low humidity alarm | 1 Bit | 1.5 alarm | CRT |
| 9 | RTC 1 - {{0:...}} | Economy mode | 1 Bit | 1.3 enable | CW |
| 9 | RTC 2 - {{0:...}} | Economy mode | 1 Bit | 1.3 enable | CW |
| 9 | RTC 3 - {{0:...}} | Economy mode | 1 Bit | 1.3 enable | CW |
| 10 | Internal sensor | High humidity alarm | 1 Bit | 1.5 alarm | CRT |
| 10 | RTC 1 - {{0:...}} | Frost/Heat protection mode | 1 Bit | 1.3 enable | CW |
| 10 | RTC 2 - {{0:...}} | Frost/Heat protection mode | 1 Bit | 1.3 enable | CW |
| 10 | RTC 3 - {{0:...}} | Frost/Heat protection mode | 1 Bit | 1.3 enable | CW |
| 11 | Internal sensor | CO2 value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 11 | RTC 1 - {{0:...}} | Standby mode | 1 Bit | 1.3 enable | CW |
| 11 | RTC 2 - {{0:...}} | Standby mode | 1 Bit | 1.3 enable | CW |
| 11 | RTC 3 - {{0:...}} | Standby mode | 1 Bit | 1.3 enable | CW |
| 12 | Internal sensor | CO2 error report | 1 Bit | 1.2 boolean | CRT |
| 12 | RTC 1 - {{0:...}} | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 12 | RTC 2 - {{0:...}} | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 12 | RTC 3 - {{0:...}} | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 13 | Internal sensor | Low CO2 alarm | 1 Bit | 1.5 alarm | CRT |
| 13 | RTC 1 - {{0:...}} | Fan automatic operation | 1 Bit | 1.3 enable | CW |
| 13 | RTC 2 - {{0:...}} | Fan automatic operation | 1 Bit | 1.3 enable | CW |
| 13 | RTC 3 - {{0:...}} | Fan automatic operation | 1 Bit | 1.3 enable | CW |
| 14 | Internal sensor | High CO2 alarm | 1 Bit | 1.5 alarm | CRT |
| 14 | RTC 1 - {{0:...}} | Window contact | 1 Bit | 1.19 window/door | CWU |
| 14 | RTC 2 - {{0:...}} | Window contact | 1 Bit | 1.19 window/door | CWU |
| 14 | RTC 3 - {{0:...}} | Window contact | 1 Bit | 1.19 window/door | CWU |
| 15 | RTC 1 - {{0:...}} | Presence detector | 1 Bit | 1.18 occupancy | CWU |
| 15 | RTC 2 - {{0:...}} | Presence detector | 1 Bit | 1.18 occupancy | CWU |
| 15 | RTC 3 - {{0:...}} | Presence detector | 1 Bit | 1.18 occupancy | CWU |
| 16 | RTC 1 - {{0:...}} | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 16 | RTC 2 - {{0:...}} | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 16 | RTC 3 - {{0:...}} | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 17 | RTC 1 - {{0:...}} | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | RTC 2 - {{0:...}} | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | RTC 3 - {{0:...}} | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 18 | RTC 1 - {{0:...}} | Comfort mode, status | 1 Bit | 1.3 enable | CRT |
| 18 | RTC 2 - {{0:...}} | Comfort mode, status | 1 Bit | 1.3 enable | CRT |
| 18 | RTC 3 - {{0:...}} | Comfort mode, status | 1 Bit | 1.3 enable | CRT |
| 19 | RTC 1 - {{0:...}} | Economy mode, status | 1 Bit | 1.3 enable | CRT |
| 19 | RTC 2 - {{0:...}} | Economy mode, status | 1 Bit | 1.3 enable | CRT |
| 19 | RTC 3 - {{0:...}} | Economy mode, status | 1 Bit | 1.3 enable | CRT |
| 20 | RTC 1 - {{0:...}} | Frost/Heat protection mode, status | 1 Bit | 1.3 enable | CRT |
| 20 | RTC 2 - {{0:...}} | Frost/Heat protection mode, status | 1 Bit | 1.3 enable | CRT |
| 20 | RTC 3 - {{0:...}} | Frost/Heat protection mode, status | 1 Bit | 1.3 enable | CRT |
| 21 | RTC 1 - {{0:...}} | Standby mode, status | 1 Bit | 1.3 enable | CRT |
| 21 | RTC 2 - {{0:...}} | Standby mode, status | 1 Bit | 1.3 enable | CRT |
| 21 | RTC 3 - {{0:...}} | Standby mode, status | 1 Bit | 1.3 enable | CRT |
| 22 | RTC 1 - {{0:...}} | Actual temperature, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 22 | RTC 2 - {{0:...}} | Actual temperature, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 22 | RTC 3 - {{0:...}} | Actual temperature, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | Input 1 - {{0:Temperature probe}} | Actual temperature, Sensor | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | Input 1 - {{0:Switch sensor}} | Switch | 1 Bit | 1.1 switch | CRWTU |
| 23 | Input 1 - {{0:Switch sensor}} | Close, Switch | 1 Bit | 1.1 switch | CRWTU |
| 23 | Input 1 - {{0:Switch sensor}} | Short, Switch | 1 Bit | 1.1 switch | CRWTU |
| 23 | Input 1 - {{0:Scene control}} | Scene | 1 Byte | 18.1 scene control | CT |
| 23 | Input 1 - {{0:Scene control}} | Close, Scene | 1 Byte | 18.1 scene control | CT |
| 23 | Input 1 - {{0:Scene control}} | Short, Scene | 1 Byte | 18.1 scene control | CT |
| 23 | Input 1 - {{0:Send String}} | String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 23 | Input 1 - {{0:Send String}} | Close, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 23 | Input 1 - {{0:Send String}} | Short, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 23 | RTC 1 - {{0:...}} | Base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | RTC 2 - {{0:...}} | Base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | RTC 3 - {{0:...}} | Base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 24 | Input 1 - {{0:Temperature probe}} | Temperature error report, Sensor | 1 Bit | 1.5 alarm | CRT |
| 24 | Input 1 - {{0:Switch sensor}} | Open, Switch | 1 Bit | 1.1 switch | CRWTU |
| 24 | Input 1 - {{0:Switch sensor}} | Long, Switch | 1 Bit | 1.1 switch | CRWTU |
| 24 | Input 1 - {{0:Scene control}} | Open, Scene | 1 Byte | 18.1 scene control | CT |
| 24 | Input 1 - {{0:Scene control}} | Long, Scene | 1 Byte | 18.1 scene control | CT |
| 24 | Input 1 - {{0:Send String}} | Open, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 24 | Input 1 - {{0:Send String}} | Long, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 24 | RTC 1 - {{0:...}} | Setpoint offset, status | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 24 | RTC 2 - {{0:...}} | Setpoint offset, status | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 24 | RTC 3 - {{0:...}} | Setpoint offset, status | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 25 | Input 1 - {{0:Switch sensor}} | Disable | 1 Bit | 1.3 enable | CW |
| 25 | Input 1 - {{0:Scene control}} | Disable | 1 Bit | 1.3 enable | CW |
| 25 | Input 1 - {{0:Send String}} | Disable | 1 Bit | 1.3 enable | CW |
| 25 | RTC 1 - {{0:...}} | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 25 | RTC 2 - {{0:...}} | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 25 | RTC 3 - {{0:...}} | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 26 | Input 2 - {{0:Temperature probe}} | Actual temperature, Sensor | 2 Bytes | 9.1 temperature (°C) | CRT |
| 26 | Input 2 - {{0:Switch sensor}} | Switch | 1 Bit | 1.1 switch | CRWTU |
| 26 | Input 2 - {{0:Switch sensor}} | Close, Switch | 1 Bit | 1.1 switch | CRWTU |
| 26 | Input 2 - {{0:Switch sensor}} | Short, Switch | 1 Bit | 1.1 switch | CRWTU |
| 26 | Input 2 - {{0:Scene control}} | Scene | 1 Byte | 18.1 scene control | CT |
| 26 | Input 2 - {{0:Scene control}} | Close, Scene | 1 Byte | 18.1 scene control | CT |
| 26 | Input 2 - {{0:Scene control}} | Short, Scene | 1 Byte | 18.1 scene control | CT |
| 26 | Input 2 - {{0:Send String}} | String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 26 | Input 2 - {{0:Send String}} | Close, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 26 | Input 2 - {{0:Send String}} | Short, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 26 | RTC 1 - {{0:...}} | Heating control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 1 - {{0:...}} | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 1 - {{0:...}} | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 1 - {{0:...}} | Heating/Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 2 - {{0:...}} | Heating control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 2 - {{0:...}} | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 2 - {{0:...}} | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 2 - {{0:...}} | Heating/Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 3 - {{0:...}} | Heating control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 3 - {{0:...}} | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 3 - {{0:...}} | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 3 - {{0:...}} | Heating/Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | Input 2 - {{0:Temperature probe}} | Temperature error report, Sensor | 1 Bit | 1.5 alarm | CRT |
| 27 | Input 2 - {{0:Switch sensor}} | Open, Switch | 1 Bit | 1.1 switch | CRWTU |
| 27 | Input 2 - {{0:Switch sensor}} | Long, Switch | 1 Bit | 1.1 switch | CRWTU |
| 27 | Input 2 - {{0:Scene control}} | Open, Scene | 1 Byte | 18.1 scene control | CT |
| 27 | Input 2 - {{0:Scene control}} | Long, Scene | 1 Byte | 18.1 scene control | CT |
| 27 | Input 2 - {{0:Send String}} | Open, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 27 | Input 2 - {{0:Send String}} | Long, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 27 | RTC 1 - {{0:...}} | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 27 | RTC 1 - {{0:...}} | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | RTC 2 - {{0:...}} | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 27 | RTC 2 - {{0:...}} | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | RTC 3 - {{0:...}} | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 27 | RTC 3 - {{0:...}} | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 28 | Input 2 - {{0:Switch sensor}} | Disable | 1 Bit | 1.3 enable | CW |
| 28 | Input 2 - {{0:Scene control}} | Disable | 1 Bit | 1.3 enable | CW |
| 28 | Input 2 - {{0:Send String}} | Disable | 1 Bit | 1.3 enable | CW |
| 28 | RTC 1 - {{0:...}} | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 28 | RTC 1 - {{0:...}} | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 28 | RTC 2 - {{0:...}} | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 28 | RTC 2 - {{0:...}} | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 28 | RTC 3 - {{0:...}} | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 28 | RTC 3 - {{0:...}} | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 29 | RTC 1 - {{0:...}} | Fan speed low | 1 Bit | 1.1 switch | CT |
| 29 | RTC 2 - {{0:...}} | Fan speed low | 1 Bit | 1.1 switch | CT |
| 29 | RTC 3 - {{0:...}} | Fan speed low | 1 Bit | 1.1 switch | CT |
| 30 | RTC 1 - {{0:...}} | Fan speed medium | 1 Bit | 1.1 switch | CT |
| 30 | RTC 2 - {{0:...}} | Fan speed medium | 1 Bit | 1.1 switch | CT |
| 30 | RTC 3 - {{0:...}} | Fan speed medium | 1 Bit | 1.1 switch | CT |
| 31 | RTC 1 - {{0:...}} | Fan speed high | 1 Bit | 1.1 switch | CT |
| 31 | RTC 2 - {{0:...}} | Fan speed high | 1 Bit | 1.1 switch | CT |
| 31 | RTC 3 - {{0:...}} | Fan speed high | 1 Bit | 1.1 switch | CT |
| 32 | RTC 1 - {{0:...}} | Fan speed off | 1 Bit | 1.1 switch | CT |
| 32 | RTC 2 - {{0:...}} | Fan speed off | 1 Bit | 1.1 switch | CT |
| 32 | RTC 3 - {{0:...}} | Fan speed off | 1 Bit | 1.1 switch | CT |
| 33 | RTC 1 - {{0:...}} | Additional heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 1 - {{0:...}} | Additional heating control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 1 - {{0:...}} | Additional heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 1 - {{0:...}} | Additional heating/cooling control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 2 - {{0:...}} | Additional heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 2 - {{0:...}} | Additional heating control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 2 - {{0:...}} | Additional heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 2 - {{0:...}} | Additional heating/cooling control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 3 - {{0:...}} | Additional heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 3 - {{0:...}} | Additional heating control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 3 - {{0:...}} | Additional heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 3 - {{0:...}} | Additional heating/cooling control value | 1 Bit | 1.1 switch | CRT |
| 34 | RTC 1 - {{0:...}} | Additional cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | RTC 1 - {{0:...}} | Additional cooling control value | 1 Bit | 1.1 switch | CRT |
| 34 | RTC 2 - {{0:...}} | Additional cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | RTC 2 - {{0:...}} | Additional cooling control value | 1 Bit | 1.1 switch | CRT |
| 34 | RTC 3 - {{0:...}} | Additional cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | RTC 3 - {{0:...}} | Additional cooling control value | 1 Bit | 1.1 switch | CRT |
| 134 | Relative humidity Level | External sensor value 1 | 2 Bytes | 9.7 humidity (%) | CWTU |
| 135 | Relative humidity Level | External sensor value 2 | 2 Bytes | 9.7 humidity (%) | CWTU |
| 136 | Relative humidity Level | External sensor value 3 | 2 Bytes | 9.7 humidity (%) | CWTU |
| 137 | Relative humidity Level | Actual sensor value | 2 Bytes | 9.7 humidity (%) | CRT |
| 138 | Relative humidity Level | Output value | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 138 | Relative humidity Level | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 138 | Relative humidity Level | Output value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 138 | Relative humidity Level | Output value | 1 Byte | 17.1 scene number | CRT |
| 138 | Relative humidity Level | Output value of level 1 | 1 Bit | 1.1 switch | CRT |
| 139 | Relative humidity Level | Output value of level 2 | 1 Bit | 1.1 switch | CRT |
| 140 | Relative humidity Level | Output value of level 3 | 1 Bit | 1.1 switch | CRT |
| 141 | Relative humidity Level | Output value of level 4 | 1 Bit | 1.1 switch | CRT |
| 142 | Relative humidity Level | Alarm message | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 143 | CO2 Level | External sensor value 1 | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 144 | CO2 Level | External sensor value 2 | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 145 | CO2 Level | External sensor value 3 | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 146 | CO2 Level | Actual sensor value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 147 | CO2 Level | Output value of level 1 | 1 Bit | 1.1 switch | CRT |
| 147 | CO2 Level | Output value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 147 | CO2 Level | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 147 | CO2 Level | Output value | 1 Byte | 17.1 scene number | CRT |
| 147 | CO2 Level | Output value | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 148 | CO2 Level | Output value of level 2 | 1 Bit | 1.1 switch | CRT |
| 149 | CO2 Level | Output value of level 3 | 1 Bit | 1.1 switch | CRT |
| 150 | CO2 Level | Output value of level 4 | 1 Bit | 1.1 switch | CRT |
| 151 | CO2 Level | Alarm message | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 170 | Relative humidity controller | Controller on/off | 1 Bit | 1.1 switch | CW |
| 172 | Relative humidity controller | External sensor value | 2 Bytes | 9.7 humidity (%) | CWTU |
| 173 | Relative humidity controller | Controller status | 1 Bit | 1.1 switch | CRT |
| 174 | Relative humidity controller | Actual sensor value | 2 Bytes | 9.7 humidity (%) | CRT |
| 175 | Relative humidity controller | Control value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 175 | Relative humidity controller | Control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 176 | Relative humidity controller | Control stop | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 176 | Relative humidity controller | Control stop | 1 Byte | 5.1 percentage (0..100%) | CW |
| 177 | CO2 controller | Controller on/off | 1 Bit | 1.1 switch | CW |
| 178 | CO2 controller | Setpoint adjustment | 2 Bytes | 9.8 parts/million (ppm) | CRW |
| 179 | CO2 controller | External sensor value | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 180 | CO2 controller | Controller status | 1 Bit | 1.1 switch | CRT |
| 181 | CO2 controller | Actual sensor value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 182 | CO2 controller | Control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 182 | CO2 controller | Control value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 183 | CO2 controller | Control stop | 1 Byte | 5.1 percentage (0..100%) | CW |
| 183 | CO2 controller | Control stop | 1 Byte | 5.10 counter pulses (0..255) | CW |
Parameters (268)
| Parameter | Type | Default |
|---|---|---|
| Send delay after voltage recovery [0..15] | unsignedInt 0…15 | 5 |
| Send cycle of In operation telegram [1..240,0=inactive] | unsignedInt 0…240 | 0 |
| Status object read request after restart | unsignedInt 0…1 | 1 |
| Input interface | unsignedInt 0…1 | 0 |
| Temperature calibration | list | 0.0 |
| Send temperature when the result change by | list | 1.0 |
| Cyclically send temperature [0...255,0=inactive] | unsignedInt 0…255 | 10 |
| Send alarm telegram for low/high temperature | list | No respond |
| Threshold value for low temperature alarm [0..15] | list | 0 |
| Threshold value for high temperature alarm [30..45] | list | 45 |
| Humidity calibration | list | 0 |
| Send humidity when the result change by [0..20,0=inactive] | unsignedInt 0…20 | 5 |
| Cyclically send humidity [0..255,0=inactive] | unsignedInt 0…255 | 10 |
| Send alarm telegram for low/high humidity | list | No respond |
| Threshold value for low humidity alarm [5..50] | unsignedInt 5…50 | 5 |
| Threshold value for high humidity alarm [55..85] | unsignedInt 55…85 | 85 |
| Function of input 1 | list | BI: Switch sensor |
| Function of input 2 | list | Disable |
| Description (max 30char.) | text | |
| B value of temperature sensor (must refer to the characteristic of component) | list | 3950 |
| Cyclically send temperature [0...255] | unsignedInt 0…255 | 0 |
| Reply error of sensor measurement | list | No respond |
| Object value of error | list | 0=no error/1=error |
| Lower threshold value for error report | list | 0 |
| Upper threshold value for error report | list | 60 |
| Distinction between short and long operation | list | No |
| Reaction on close the contact | list | TOGGLE |
| Reaction on open the contact | list | No reaction |
| Send object value after voltage recovery (valid if reaction is not toggle) | list | No |
| Number of objects | list | 1 |
| Long operation after [3..25] | unsignedInt 3…25 | 5 |
| Connected contact type | list | Normally open |
| Reaction on short operation | list | TOGGLE |
| Reaction on long operation | list | No reaction |
| Disable function | list | Disable |
| Reaction on close the contact | list | Recall scene |
| 8 bit scene number | list | Scene No.1 |
| Reaction on short operation | list | Recall scene |
| Reaction on close the contact | list | Send Value |
| String (14byte) value | text | Hello, world ! |
| Send object value after voltage recovery | list | No |
| Reaction on short operation | list | Send Value |
| Room temperature controller | unsignedInt 0…1 | 0 |
| Air Quality Level function | unsignedInt 0…1 | 0 |
| Air Quality controller | unsignedInt 0…1 | 0 |
| CO2 calibration | list | 0 |
| Send CO2 when the result change | list | 50 |
| Cyclically send CO2 [0..255,0=inactive] | unsignedInt 0…255 | 10 |
| Threshold value for low CO2 alarm [400..2000] | unsignedInt 400…2000 | 400 |
| Threshold value for high CO2 alarm [400..2000] | unsignedInt 400…2000 | 2000 |
| Report error when sensor failure | unsignedInt 0…1 | 0 |
| Send alarm telegram for low/high CO2 | list | No respond |
| RTC 1 | unsignedInt 0…1 | 0 |
| RTC 2 | unsignedInt 0…1 | 0 |
| RTC 3 | unsignedInt 0…1 | 0 |
| Relative humidity level function | list | Disable |
| Reference internal sensor | unsignedInt 0…1 | 1 |
| Number of reference external sensor | list | 0 |
| Number of reference external sensor | list | 1 |
| Calculation type | list | Weight average |
| Weighting of internal sensor | list | 50 |
| Weighting of external sensor 1 | list | 20 |
| Weighting of external sensor 2 | list | 20 |
| Weighting of external sensor 3 | list | 10 |
| Time period for request external sensor [0...255,0=inactive] | unsignedInt 0…255 | 10 |
| Send value when the result change by | list | 5 |
| Cyclically send value [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Control type | list | 1bit |
| Object datatype | list | 1byte percentage value |
| Cyclically send output value [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Hysteresis threshold value in +/- [1..10] | list | 5 |
| Send additional alarm message | unsignedInt 0…1 | 0 |
| Threshold value 1 for level 1 | unsignedInt 0…100 | 20 |
| Threshold value 2 for level 2 | unsignedInt 0…100 | 40 |
| Threshold value 3 for level 3 | unsignedInt 0…100 | 50 |
| Threshold value 4 for level 4 | unsignedInt 0…100 | 60 |
| If humidity value < threshold value 1, send | list | OFF |
| If humidity value >= threshold value 1, send | list | ON |
| If sensor failure, send | list | Nothing |
| If humidity value < threshold value 2, send | list | OFF |
| If humidity value >= threshold value 2, send | list | ON |
| If humidity value < threshold value 3, send | list | OFF |
| If humidity value >= threshold value 3, send | list | ON |
| If humidity value < threshold value 4, send | list | OFF |
| If humidity value >= threshold value 4, send | list | ON |
| Threshold value 1 (Level 1<->Level 2) | unsignedInt 0…100 | 20 |
| Threshold value 2 (Level 2<->Level 3) | unsignedInt 0…100 | 40 |
| Threshold value 3 (Level 3<->Level 4) | unsignedInt 0…100 | 50 |
| If humidity value < threshold value 1, send | list | Send value |
| Value | list | 0 |
| Value | unsignedInt 0…255 | 0 |
| Value | list | Scene No.1 |
| Value | color | #00FF00 |
| Alarm message | text | Alarm 1 |
| If threshold value 1 <= humidity value < threshold value 2, send | list | Send value |
| Value | list | 33 |
| Value | unsignedInt 0…255 | 1 |
| Value | list | Scene No.2 |
| Value | color | #FFFF00 |
| Alarm message | text | Alarm 2 |
| If threshold value 2 <= humidity value < threshold value 3, send | list | Send value |
| Value | list | 67 |
| Value | unsignedInt 0…255 | 2 |
| Value | list | Scene No.3 |
| Value | color | #FF8000 |
| Alarm message | text | Alarm 3 |
| If humidity value >= threshold value 3, send | list | Send value |
| Value | list | 100 |
| Value | unsignedInt 0…255 | 3 |
| Value | list | Scene No.4 |
| Value | color | #FF0000 |
| Alarm message | text | Alarm 4 |
| If humidity value >= threshold value 1, send | list | Send value |
| If humidity value >= threshold value 2, send | list | Send value |
| Value | list | Scene No.5 |
| CO2 level function | list | Disable |
| Send value when the result change by | list | 50 |
| Hysteresis threshold value in +/- [50..300] | unsignedInt 50…300 | 50 |
| Threshold value 1 for level 1 | unsignedInt 1…2000 | 350 |
| If CO2 value < threshold value 1, send | list | OFF |
| If CO2 value >= threshold value 1, send | list | ON |
| Threshold value 2 for level 2 | unsignedInt 1…2000 | 450 |
| If CO2 value < threshold value 2, send | list | OFF |
| If CO2 value >= threshold value 2, send | list | ON |
| Threshold value 3 for level 3 | unsignedInt 1…2000 | 1000 |
| If CO2 value < threshold value 3, send | list | OFF |
| If CO2 value >= threshold value 3, send | list | ON |
| Threshold value 4 for level 4 | unsignedInt 1…2000 | 1500 |
| If CO2 value < threshold value 4, send | list | OFF |
| If CO2 value >= threshold value 4, send | list | ON |
| Threshold value 1 (Level 1<->Level 2) | unsignedInt 1…2000 | 350 |
| Threshold value 2 (Level 2<->Level 3) | unsignedInt 1…2000 | 450 |
| Threshold value 3 (Level 3<->Level 4) | unsignedInt 1…2000 | 1000 |
| If CO2 value < threshold value 1, send | list | Send value |
| If threshold value 1 <= CO2 value < threshold value 2, send | list | Send value |
| If threshold value 2 <= CO2 value < threshold value 3, send | list | Send value |
| If CO2 value >= threshold value 3, send | list | Send value |
| Relative humidity controller function | list | Disable |
| Relative humidity reference from | list | Internal sensor |
| Combination ratio | list | 50% Internal to 50% External |
| Control type | list | 1byte |
| Cyclically send control value [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Control value for step 0 | list | 0 |
| Control value for step 0 | unsignedInt 0…255 | 0 |
| Control value for step 1 | list | 33 |
| Control value for step 1 | unsignedInt 0…255 | 1 |
| Control value for step 2 | list | 67 |
| Control value for step 2 | unsignedInt 0…255 | 2 |
| Control value for step 3 | list | 100 |
| Control value for step 3 | unsignedInt 0…255 | 3 |
| Threshold value 1 (step 0<->step 1) | unsignedInt 0…100 | 20 |
| Threshold value 2 (step 1<->step 2) | unsignedInt 0…100 | 40 |
| Threshold value 3 (step 2<->step 3) | unsignedInt 0…100 | 50 |
| Minimum time in step control [0..65535] | unsignedInt 0…65535 | 0 |
| If sensor failure, send | list | 0 |
| If sensor failure, send | unsignedInt 0…255 | 0 |
| Stop function | unsignedInt 0…1 | 0 |
| Controller automatically restart after [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Behaviour when controller off | list | Nothing |
| CO2 controller function | list | Disable |
| CO2 reference from | list | Internal sensor |
| Threshold value 1 (step 0<->step 1) | unsignedInt 1…2000 | 350 |
| Threshold value 2 (step 1<->step 2) | unsignedInt 1…2000 | 450 |
| Threshold value 3 (step 2<->step 3) | unsignedInt 1…2000 | 1000 |
| Setpoint CO2 value | unsignedInt 1…1500 | 500 |
| Setpoint value can be changed via bus | unsignedInt 0…1 | 0 |
| Proportional range | list | 100 |
| Reset time [15..240] | unsignedInt 15…240 | 15 |
| Minimum control value | list | 0 |
| Minimum control value | unsignedInt 0…255 | 0 |
| Maximum control value | list | 100 |
| Maximum control value | unsignedInt 0…255 | 255 |
| Sensor Failure Para display or not | unsignedInt 0…1 | 0 |
| Send value when the control value change by [0..100,0=inactive] | list | 5 |
| Send value when the control value change by [0..255,0=inactive] | unsignedInt 0…255 | 15 |
| Control value lower than the minimum value | list | 0%=0%, otherwise=Minimum value |
| Control value lower than the minimum value | list | 0=0, otherwise=Minimum value |
| Alarm function | unsignedInt 0…1 | 0 |
| Alarm tone time period | list | 10s |
| Alarm tone time automatically repeat interval time | list | 1min |
| Acknowledge from bus | list | Disable |
| Room temperature reference from | list | Internal sensor |
| Time period for request room temperature sensor [0...255] | unsignedInt 0…255 | 10 |
| Control value after temp. error[0..100] (if 2-point control, set value '0'=0, set value '>0'=1) | unsignedInt 0…100 | 0 |
| Room temperature control mode | list | Heating |
| Heating/Cooling switchover | list | Via object |
| Heating/Cooling status after download | list | Heating |
| Heating/Cooling status after voltage recovery | list | As before voltage failure |
| Room temperature control system | list | 4 pipes system |
| Operation mode | unsignedInt 0…1 | 0 |
| Initial setpoint temperature | list | 20.0 |
| Temperature error tip_setpoint/Max | unsignedInt 0…1 | 0 |
| Temperature error tip_setpoint/Min | unsignedInt 0…1 | 0 |
| Upper dead zone | list | 2.0 |
| Lower dead zone | list | 2.0 |
| Controller status after download | list | Comfort mode |
| Controller status after voltage recovery | list | As before voltage failure |
| Extended comfort mode [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| 1 bit object function for operation mode | unsignedInt 0…1 | 0 |
| 1 bit object for standby mode | unsignedInt 0…1 | 1 |
| Fan speed auto.control function | unsignedInt 0…1 | 0 |
| Window contact input function | unsignedInt 0…1 | 0 |
| Delay for window contact [0..65535] | unsignedInt 0…65535 | 15 |
| Controller mode for open window | list | Frost/heat protection |
| Bus presence detector function | unsignedInt 0…1 | 0 |
| Setpoint method for operating mode | list | Absolute |
| Base setpoint temperature | list | 20.0 |
| Additional setpoint offset for setpoint adjustment | list | Disable |
| Step of setpoint offset | list | 0.5K |
| Min. setpoint offset [-10..0] | signedInt -10…0 | -5 |
| Max. setpoint offset [0..10] | unsignedInt 0…10 | 5 |
| Reduced heating in standby mode [0..10] | list | 2 |
| Reduced heating in economy mode [0..10] | list | 4 |
| Setpoint temperature in frost protection mode [5..10] | list | 7 |
| Increased cooling in standby mode [0..10] | list | 2 |
| Increased cooling in economy mode [0..10] | list | 4 |
| Setpoint temperature in heat protection mode [30..37] | list | 35 |
| Min. setpoint temperature [5..37] | list | 11 |
| Max. setpoint temperature [5..37] | list | 32 |
| Setpoint temperature in comfort mode [5..37] | list | 21 |
| Setpoint temperature in standby mode [5..37] | list | 19 |
| Setpoint temperature in economy mode [5..37] | list | 17 |
| Setpoint temperature in comfort mode [5..37] | list | 23 |
| Setpoint temperature in standby mode [5..37] | list | 25 |
| Setpoint temperature in economy mode [5..37] | list | 27 |
| Minimum zone between heating and cooling setpoint | list | 2.0 |
| Type of heating control | list | Switching on/off(use 2-point control) |
| Invert control value | list | No |
| Lower Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| Upper Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| PWM cycle time [1..255] | unsignedInt 1…255 | 15 |
| Heating speed | list | Hot water heating(5K/150min) |
| Proportional range [10..100] | unsignedInt 0…100 | 40 |
| Reset time [0..255] | unsignedInt 0…255 | 150 |
| Send control value on change by [0..100,0=inactive] | unsignedInt 0…100 | 5 |
| Cyclically send control value [0..255] | unsignedInt 0…255 | 10 |
| Type of cooling control | list | Switching on/off(use 2-point control) |
| Cooling speed | list | Cooling ceiling (5K/240min) |
| Proportional range [10..100] | unsignedInt 10…100 | 40 |
| Type of heating/cooling control | list | Switching on/off(use 2-point control) |
| Auto. operation on object value | list | Auto=1/Man.=0 |
| Object datatype of 1byte fan speed | list | Percentage (DPT_5.001) |
| Output value for fan speed low | unsignedInt 1…255 | 1 |
| Output value for fan speed medium | unsignedInt 1…255 | 2 |
| Output value for fan speed high | unsignedInt 1…255 | 3 |
| Output value for fan speed low | unsignedInt 1…100 | 33 |
| Output value for fan speed medium | unsignedInt 1…100 | 67 |
| Output value for fan speed high | unsignedInt 1…100 | 100 |
| 1 bit object function for fan speed | unsignedInt 0…1 | 0 |
| 1 bit object for fan speed off | unsignedInt 0…1 | 0 |
| Threshold value speed OFF<-->low [1..255] | unsignedInt 1…255 | 80 |
| Threshold value speed low<-->medium [1..255] | unsignedInt 1…255 | 150 |
| Threshold value speed medium<-->high [1..255] | unsignedInt 1…255 | 200 |
| Hysteresis threshold value in +/-[0..50] | unsignedInt 0…50 | 10 |
| Temperature difference speed OFF<-->low [1..200] | unsignedInt 0…200 | 20 |
| Temperature difference speed low<-->medium [1..200] | unsignedInt 0…200 | 30 |
| Temperature difference speed medium<-->high [1..200] | unsignedInt 0…200 | 40 |
| Hysteresis temperature difference in [0..50] | unsignedInt 0…50 | 10 |
| Minimum time in fan speed [0..65535] | unsignedInt 0…65535 | 60 |
| Additional heating | unsignedInt 0…1 | 0 |
| Invert control value | unsignedInt 0…1 | 0 |
| Temperature difference to switch on additional heating [-100..-5] | signedInt -100…-5 | -25 |
| Hysteresis to switch off additional heating [-20..-1] | signedInt -20…-1 | -5 |
| Cyclically send control value [0..255] | unsignedInt 0…255 | 0 |
| Additional cooling | unsignedInt 0…1 | 0 |
| Temperature difference to switch on additional cooling [5..100] | unsignedInt 5…100 | 25 |
| Hysteresis to switch off additional cooling [1..20] | unsignedInt 1…20 | 5 |
| Additional heating/cooling | unsignedInt 0…1 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Carbon Dioxide Sensor 1.0 latest | $4103 | 4918 | 2026-11-25 | 177 KB | Download |
About this file
This is the official ETS product database for the Honeywell Building Technologies Honeywell KNX Carbon Dioxide Sensor (KNX CO2 SENSOR), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Honeywell Building Technologies
- Honeywell MK HVAC Module HKLS-FCU
- Honeywell KNX IP54 Microwave Sensor HNX MWV30IP54
- Honeywell KNX Surface PIR Sensor 24D Coverage HNX PIR 24D
- Honeywell KNX Thermostat 6Fold HNX TSTAT xx
- Honeywell MK Thermostats KNX BT TEMP
- Honeywell MK Dimmer 4CH 1.5A 300W KNX DIM 4CH 300W
- Honeywell MK DIM 6CH 0-10V KNX DIM 6CH 0-10V
- Honeywell KNX Microwave sensor KNX MWV FL
- Honeywell MK PIR Sensor KNX PIR Sensor
- Honeywell MK Timer KNX Timer
- Honeywell MK 24-Zone Dry Contact Module HKLS-IO24
- Honeywell KNX Line Coupler Secure HNX LN CPL SEC