KNX CO2 sensor,55mm CHAQ-03/55.2.0x
GVS · Order number CHAQ-03/55.2.0x · Sensor › Air quality
Download .knxprod Temperature/Humidity/CO2 sensor with controller/1.0 1.0 · 190 KB
Product
| Manufacturer | GVS |
|---|---|
| Product name | KNX CO2 sensor,55mm |
| Order number | CHAQ-03/55.2.0x |
| Hardware | KNX CO2 sensor,55mm |
| Medium | Twisted Pair |
| Bus current (mA) | 17 |
| Rail mounted | No |
| Registration | Certified · 2023-11-02 |
| Languages | de-DE, en-US |
| Catalog entry | M-0085_H-CH23EA-1_HP-009A-10-3AB3_CI-CHAQ.2D03.2F55.2E2.2E0x-1 |
| Fingerprint | 3AB3 |
| SHA-256 | cb94756aca49225572a809ae2ef185fa293d36f5f489b5e12fd03a8b40b20eec |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Temperature/Humidity/CO2 sensor with controller/1.0 1.0
| Application number | $009A |
|---|---|
| Version | 1.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 386 |
| Group objects | 231 |
Group objects (231)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | RTC 1 - {{0:...}} | Power on/off | 1 Bit | 1.1 switch | CRW |
| 0 | RTC 2 - {{0:...}} | Power on/off | 1 Bit | 1.1 switch | CRW |
| 0 | RTC 3 - {{0:...}} | Power on/off | 1 Bit | 1.1 switch | CRW |
| 1 | General | In operation | 1 Bit | 1.1 switch | CRT |
| 1 | RTC 1 - {{0:...}} | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | RTC 2 - {{0:...}} | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 1 | RTC 3 - {{0:...}} | External temperature sensor | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 2 | General | Alarm input | 1 Bit | 1.5 alarm | CWTU |
| 2 | RTC 1 - {{0:...}} | Base setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 1 - {{0:...}} | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 2 - {{0:...}} | Base setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 2 - {{0:...}} | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 3 - {{0:...}} | Base setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 2 | RTC 3 - {{0:...}} | Current setpoint adjustment | 2 Bytes | 9.1 temperature (°C) | CW |
| 3 | General | Alarm acknowledge | 1 Bit | 1.16 acknowledge | CW |
| 3 | RTC 1 - {{0:...}} | Setpoint offset | 1 Bit | 1.7 step | CW |
| 3 | RTC 2 - {{0:...}} | Setpoint offset | 1 Bit | 1.7 step | CW |
| 3 | RTC 3 - {{0:...}} | Setpoint offset | 1 Bit | 1.7 step | CW |
| 4 | RTC 1 - {{0:...}} | Float offset value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 4 | RTC 2 - {{0:...}} | Float offset value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 4 | RTC 3 - {{0:...}} | Float offset value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 5 | Internal sensor | Temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 5 | RTC 1 - {{0:...}} | Setpoint offset reset | 1 Bit | 1.15 reset | CW |
| 5 | RTC 2 - {{0:...}} | Setpoint offset reset | 1 Bit | 1.15 reset | CW |
| 5 | RTC 3 - {{0:...}} | Setpoint offset reset | 1 Bit | 1.15 reset | CW |
| 6 | Internal sensor | Low temperature alarm | 1 Bit | 1.5 alarm | CRT |
| 6 | RTC 1 - {{0:...}} | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CW |
| 6 | RTC 2 - {{0:...}} | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CW |
| 6 | RTC 3 - {{0:...}} | Heating/Cooling mode | 1 Bit | 1.100 cooling/heating | CW |
| 7 | Internal sensor | High temperature alarm | 1 Bit | 1.5 alarm | CRT |
| 7 | RTC 1 - {{0:...}} | Operation mode | 1 Byte | 20.102 HVAC mode | CW |
| 7 | RTC 2 - {{0:...}} | Operation mode | 1 Byte | 20.102 HVAC mode | CW |
| 7 | RTC 3 - {{0:...}} | Operation mode | 1 Byte | 20.102 HVAC mode | CW |
| 8 | Internal sensor | Humidity value | 2 Bytes | 9.7 humidity (%) | CRT |
| 8 | RTC 1 - {{0:...}} | Comfort mode | 1 Bit | 1.3 enable | CW |
| 8 | RTC 2 - {{0:...}} | Comfort mode | 1 Bit | 1.3 enable | CW |
| 8 | RTC 3 - {{0:...}} | Comfort mode | 1 Bit | 1.3 enable | CW |
| 9 | Internal sensor | Low humidity alarm | 1 Bit | 1.5 alarm | CRT |
| 9 | RTC 1 - {{0:...}} | Economy mode | 1 Bit | 1.3 enable | CW |
| 9 | RTC 2 - {{0:...}} | Economy mode | 1 Bit | 1.3 enable | CW |
| 9 | RTC 3 - {{0:...}} | Economy mode | 1 Bit | 1.3 enable | CW |
| 10 | Internal sensor | High humidity alarm | 1 Bit | 1.5 alarm | CRT |
| 10 | RTC 1 - {{0:...}} | Frost/Heat protection mode | 1 Bit | 1.3 enable | CW |
| 10 | RTC 2 - {{0:...}} | Frost/Heat protection mode | 1 Bit | 1.3 enable | CW |
| 10 | RTC 3 - {{0:...}} | Frost/Heat protection mode | 1 Bit | 1.3 enable | CW |
| 11 | Internal sensor | CO2 value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 11 | RTC 1 - {{0:...}} | Standby mode | 1 Bit | 1.3 enable | CW |
| 11 | RTC 2 - {{0:...}} | Standby mode | 1 Bit | 1.3 enable | CW |
| 11 | RTC 3 - {{0:...}} | Standby mode | 1 Bit | 1.3 enable | CW |
| 12 | Internal sensor | CO2 error report | 1 Bit | 1.2 boolean | CRT |
| 12 | RTC 1 - {{0:...}} | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 12 | RTC 2 - {{0:...}} | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 12 | RTC 3 - {{0:...}} | Extended comfort mode | 1 Bit | 1.16 acknowledge | CW |
| 13 | Internal sensor | Low CO2 alarm | 1 Bit | 1.5 alarm | CRT |
| 13 | RTC 1 - {{0:...}} | Fan automatic operation | 1 Bit | 1.3 enable | CW |
| 13 | RTC 2 - {{0:...}} | Fan automatic operation | 1 Bit | 1.3 enable | CW |
| 13 | RTC 3 - {{0:...}} | Fan automatic operation | 1 Bit | 1.3 enable | CW |
| 14 | Internal sensor | High CO2 alarm | 1 Bit | 1.5 alarm | CRT |
| 14 | RTC 1 - {{0:...}} | Window contact | 1 Bit | 1.19 window/door | CWU |
| 14 | RTC 2 - {{0:...}} | Window contact | 1 Bit | 1.19 window/door | CWU |
| 14 | RTC 3 - {{0:...}} | Window contact | 1 Bit | 1.19 window/door | CWU |
| 15 | RTC 1 - {{0:...}} | Presence detector | 1 Bit | 1.18 occupancy | CWU |
| 15 | RTC 2 - {{0:...}} | Presence detector | 1 Bit | 1.18 occupancy | CWU |
| 15 | RTC 3 - {{0:...}} | Presence detector | 1 Bit | 1.18 occupancy | CWU |
| 16 | RTC 1 - {{0:...}} | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 16 | RTC 2 - {{0:...}} | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 16 | RTC 3 - {{0:...}} | Heating/Cooling mode, status | 1 Bit | 1.100 cooling/heating | CRT |
| 17 | RTC 1 - {{0:...}} | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | RTC 2 - {{0:...}} | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | RTC 3 - {{0:...}} | Operation mode, status | 1 Byte | 20.102 HVAC mode | CRT |
| 18 | RTC 1 - {{0:...}} | Comfort mode, status | 1 Bit | 1.3 enable | CRT |
| 18 | RTC 2 - {{0:...}} | Comfort mode, status | 1 Bit | 1.3 enable | CRT |
| 18 | RTC 3 - {{0:...}} | Comfort mode, status | 1 Bit | 1.3 enable | CRT |
| 19 | RTC 1 - {{0:...}} | Economy mode, status | 1 Bit | 1.3 enable | CRT |
| 19 | RTC 2 - {{0:...}} | Economy mode, status | 1 Bit | 1.3 enable | CRT |
| 19 | RTC 3 - {{0:...}} | Economy mode, status | 1 Bit | 1.3 enable | CRT |
| 20 | RTC 1 - {{0:...}} | Frost/Heat protection mode, status | 1 Bit | 1.3 enable | CRT |
| 20 | RTC 2 - {{0:...}} | Frost/Heat protection mode, status | 1 Bit | 1.3 enable | CRT |
| 20 | RTC 3 - {{0:...}} | Frost/Heat protection mode, status | 1 Bit | 1.3 enable | CRT |
| 21 | RTC 1 - {{0:...}} | Standby mode, status | 1 Bit | 1.3 enable | CRT |
| 21 | RTC 2 - {{0:...}} | Standby mode, status | 1 Bit | 1.3 enable | CRT |
| 21 | RTC 3 - {{0:...}} | Standby mode, status | 1 Bit | 1.3 enable | CRT |
| 22 | RTC 1 - {{0:...}} | Actual temperature, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 22 | RTC 2 - {{0:...}} | Actual temperature, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 22 | RTC 3 - {{0:...}} | Actual temperature, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | Input 1 - {{0:Temperature probe}} | Actual temperature, Sensor | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | Input 1 - {{0:Switch sensor}} | Switch | 1 Bit | 1.1 switch | CRWTU |
| 23 | Input 1 - {{0:Switch sensor}} | Close, Switch | 1 Bit | 1.1 switch | CRWTU |
| 23 | Input 1 - {{0:Switch sensor}} | Short, Switch | 1 Bit | 1.1 switch | CRWTU |
| 23 | Input 1 - {{0:Scene control}} | Scene | 1 Byte | 18.1 scene control | CT |
| 23 | Input 1 - {{0:Scene control}} | Close, Scene | 1 Byte | 18.1 scene control | CT |
| 23 | Input 1 - {{0:Scene control}} | Short, Scene | 1 Byte | 18.1 scene control | CT |
| 23 | Input 1 - {{0:Send String}} | String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 23 | Input 1 - {{0:Send String}} | Close, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 23 | Input 1 - {{0:Send String}} | Short, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 23 | RTC 1 - {{0:...}} | Base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | RTC 2 - {{0:...}} | Base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 23 | RTC 3 - {{0:...}} | Base temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 24 | Input 1 - {{0:Temperature probe}} | Temperature error report, Sensor | 1 Bit | 1.5 alarm | CRT |
| 24 | Input 1 - {{0:Switch sensor}} | Open, Switch | 1 Bit | 1.1 switch | CRWTU |
| 24 | Input 1 - {{0:Switch sensor}} | Long, Switch | 1 Bit | 1.1 switch | CRWTU |
| 24 | Input 1 - {{0:Scene control}} | Open, Scene | 1 Byte | 18.1 scene control | CT |
| 24 | Input 1 - {{0:Scene control}} | Long, Scene | 1 Byte | 18.1 scene control | CT |
| 24 | Input 1 - {{0:Send String}} | Open, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 24 | Input 1 - {{0:Send String}} | Long, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 24 | RTC 1 - {{0:...}} | Setpoint offset, status | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 24 | RTC 2 - {{0:...}} | Setpoint offset, status | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 24 | RTC 3 - {{0:...}} | Setpoint offset, status | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 25 | Input 1 - {{0:Switch sensor}} | Disable | 1 Bit | 1.3 enable | CW |
| 25 | Input 1 - {{0:Scene control}} | Disable | 1 Bit | 1.3 enable | CW |
| 25 | Input 1 - {{0:Send String}} | Disable | 1 Bit | 1.3 enable | CW |
| 25 | RTC 1 - {{0:...}} | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 25 | RTC 2 - {{0:...}} | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 25 | RTC 3 - {{0:...}} | Current temperature setpoint, status | 2 Bytes | 9.1 temperature (°C) | CRT |
| 26 | Input 2 - {{0:Temperature probe}} | Actual temperature, Sensor | 2 Bytes | 9.1 temperature (°C) | CRT |
| 26 | Input 2 - {{0:Switch sensor}} | Switch | 1 Bit | 1.1 switch | CRWTU |
| 26 | Input 2 - {{0:Switch sensor}} | Close, Switch | 1 Bit | 1.1 switch | CRWTU |
| 26 | Input 2 - {{0:Switch sensor}} | Short, Switch | 1 Bit | 1.1 switch | CRWTU |
| 26 | Input 2 - {{0:Scene control}} | Scene | 1 Byte | 18.1 scene control | CT |
| 26 | Input 2 - {{0:Scene control}} | Close, Scene | 1 Byte | 18.1 scene control | CT |
| 26 | Input 2 - {{0:Scene control}} | Short, Scene | 1 Byte | 18.1 scene control | CT |
| 26 | Input 2 - {{0:Send String}} | String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 26 | Input 2 - {{0:Send String}} | Close, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 26 | Input 2 - {{0:Send String}} | Short, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 26 | RTC 1 - {{0:...}} | Heating control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 1 - {{0:...}} | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 1 - {{0:...}} | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 1 - {{0:...}} | Heating/Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 2 - {{0:...}} | Heating control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 2 - {{0:...}} | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 2 - {{0:...}} | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 2 - {{0:...}} | Heating/Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 3 - {{0:...}} | Heating control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 3 - {{0:...}} | Heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 26 | RTC 3 - {{0:...}} | Heating/Cooling control value | 1 Bit | 1.1 switch | CRT |
| 26 | RTC 3 - {{0:...}} | Heating/Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | Input 2 - {{0:Temperature probe}} | Temperature error report, Sensor | 1 Bit | 1.5 alarm | CRT |
| 27 | Input 2 - {{0:Switch sensor}} | Open, Switch | 1 Bit | 1.1 switch | CRWTU |
| 27 | Input 2 - {{0:Switch sensor}} | Long, Switch | 1 Bit | 1.1 switch | CRWTU |
| 27 | Input 2 - {{0:Scene control}} | Open, Scene | 1 Byte | 18.1 scene control | CT |
| 27 | Input 2 - {{0:Scene control}} | Long, Scene | 1 Byte | 18.1 scene control | CT |
| 27 | Input 2 - {{0:Send String}} | Open, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 27 | Input 2 - {{0:Send String}} | Long, String | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 27 | RTC 1 - {{0:...}} | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 27 | RTC 1 - {{0:...}} | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | RTC 2 - {{0:...}} | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 27 | RTC 2 - {{0:...}} | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | RTC 3 - {{0:...}} | Cooling control value | 1 Bit | 1.1 switch | CRT |
| 27 | RTC 3 - {{0:...}} | Cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 28 | Input 2 - {{0:Switch sensor}} | Disable | 1 Bit | 1.3 enable | CW |
| 28 | Input 2 - {{0:Scene control}} | Disable | 1 Bit | 1.3 enable | CW |
| 28 | Input 2 - {{0:Send String}} | Disable | 1 Bit | 1.3 enable | CW |
| 28 | RTC 1 - {{0:...}} | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 28 | RTC 1 - {{0:...}} | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 28 | RTC 2 - {{0:...}} | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 28 | RTC 2 - {{0:...}} | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 28 | RTC 3 - {{0:...}} | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CT |
| 28 | RTC 3 - {{0:...}} | Fan speed | 1 Byte | 5.1 percentage (0..100%) | CT |
| 29 | RTC 1 - {{0:...}} | Fan speed low | 1 Bit | 1.1 switch | CT |
| 29 | RTC 2 - {{0:...}} | Fan speed low | 1 Bit | 1.1 switch | CT |
| 29 | RTC 3 - {{0:...}} | Fan speed low | 1 Bit | 1.1 switch | CT |
| 30 | RTC 1 - {{0:...}} | Fan speed medium | 1 Bit | 1.1 switch | CT |
| 30 | RTC 2 - {{0:...}} | Fan speed medium | 1 Bit | 1.1 switch | CT |
| 30 | RTC 3 - {{0:...}} | Fan speed medium | 1 Bit | 1.1 switch | CT |
| 31 | RTC 1 - {{0:...}} | Fan speed high | 1 Bit | 1.1 switch | CT |
| 31 | RTC 2 - {{0:...}} | Fan speed high | 1 Bit | 1.1 switch | CT |
| 31 | RTC 3 - {{0:...}} | Fan speed high | 1 Bit | 1.1 switch | CT |
| 32 | RTC 1 - {{0:...}} | Fan speed off | 1 Bit | 1.1 switch | CT |
| 32 | RTC 2 - {{0:...}} | Fan speed off | 1 Bit | 1.1 switch | CT |
| 32 | RTC 3 - {{0:...}} | Fan speed off | 1 Bit | 1.1 switch | CT |
| 33 | RTC 1 - {{0:...}} | Additional heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 1 - {{0:...}} | Additional heating control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 1 - {{0:...}} | Additional heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 1 - {{0:...}} | Additional heating/cooling control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 2 - {{0:...}} | Additional heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 2 - {{0:...}} | Additional heating control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 2 - {{0:...}} | Additional heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 2 - {{0:...}} | Additional heating/cooling control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 3 - {{0:...}} | Additional heating control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 3 - {{0:...}} | Additional heating control value | 1 Bit | 1.1 switch | CRT |
| 33 | RTC 3 - {{0:...}} | Additional heating/cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | RTC 3 - {{0:...}} | Additional heating/cooling control value | 1 Bit | 1.1 switch | CRT |
| 34 | RTC 1 - {{0:...}} | Additional cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | RTC 1 - {{0:...}} | Additional cooling control value | 1 Bit | 1.1 switch | CRT |
| 34 | RTC 2 - {{0:...}} | Additional cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | RTC 2 - {{0:...}} | Additional cooling control value | 1 Bit | 1.1 switch | CRT |
| 34 | RTC 3 - {{0:...}} | Additional cooling control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 34 | RTC 3 - {{0:...}} | Additional cooling control value | 1 Bit | 1.1 switch | CRT |
| 134 | Relative humidity Level | External sensor value 1 | 2 Bytes | 9.7 humidity (%) | CWTU |
| 135 | Relative humidity Level | External sensor value 2 | 2 Bytes | 9.7 humidity (%) | CWTU |
| 136 | Relative humidity Level | External sensor value 3 | 2 Bytes | 9.7 humidity (%) | CWTU |
| 137 | Relative humidity Level | Actual sensor value | 2 Bytes | 9.7 humidity (%) | CRT |
| 138 | Relative humidity Level | Output value | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 138 | Relative humidity Level | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 138 | Relative humidity Level | Output value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 138 | Relative humidity Level | Output value | 1 Byte | 17.1 scene number | CRT |
| 138 | Relative humidity Level | Output value of level 1 | 1 Bit | 1.1 switch | CRT |
| 139 | Relative humidity Level | Output value of level 2 | 1 Bit | 1.1 switch | CRT |
| 140 | Relative humidity Level | Output value of level 3 | 1 Bit | 1.1 switch | CRT |
| 141 | Relative humidity Level | Output value of level 4 | 1 Bit | 1.1 switch | CRT |
| 142 | Relative humidity Level | Alarm message | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 143 | CO2 Level | External sensor value 1 | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 144 | CO2 Level | External sensor value 2 | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 145 | CO2 Level | External sensor value 3 | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 146 | CO2 Level | Actual sensor value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 147 | CO2 Level | Output value of level 1 | 1 Bit | 1.1 switch | CRT |
| 147 | CO2 Level | Output value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 147 | CO2 Level | Output value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 147 | CO2 Level | Output value | 1 Byte | 17.1 scene number | CRT |
| 147 | CO2 Level | Output value | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 148 | CO2 Level | Output value of level 2 | 1 Bit | 1.1 switch | CRT |
| 149 | CO2 Level | Output value of level 3 | 1 Bit | 1.1 switch | CRT |
| 150 | CO2 Level | Output value of level 4 | 1 Bit | 1.1 switch | CRT |
| 151 | CO2 Level | Alarm message | 14 Bytes | 16.1 Character String (ISO 8859-1) | CT |
| 170 | Relative humidity controller | Controller on/off | 1 Bit | 1.1 switch | CW |
| 172 | Relative humidity controller | External sensor value | 2 Bytes | 9.7 humidity (%) | CWTU |
| 173 | Relative humidity controller | Controller status | 1 Bit | 1.1 switch | CRT |
| 174 | Relative humidity controller | Actual sensor value | 2 Bytes | 9.7 humidity (%) | CRT |
| 175 | Relative humidity controller | Control value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 175 | Relative humidity controller | Control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 176 | Relative humidity controller | Control stop | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 176 | Relative humidity controller | Control stop | 1 Byte | 5.1 percentage (0..100%) | CW |
| 177 | CO2 controller | Controller on/off | 1 Bit | 1.1 switch | CW |
| 178 | CO2 controller | Setpoint adjustment | 2 Bytes | 9.8 parts/million (ppm) | CRW |
| 179 | CO2 controller | External sensor value | 2 Bytes | 9.8 parts/million (ppm) | CWTU |
| 180 | CO2 controller | Controller status | 1 Bit | 1.1 switch | CRT |
| 181 | CO2 controller | Actual sensor value | 2 Bytes | 9.8 parts/million (ppm) | CRT |
| 182 | CO2 controller | Control value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 182 | CO2 controller | Control value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 183 | CO2 controller | Control stop | 1 Byte | 5.1 percentage (0..100%) | CW |
| 183 | CO2 controller | Control stop | 1 Byte | 5.10 counter pulses (0..255) | CW |
Parameters (268)
| Parameter | Type | Default |
|---|---|---|
| Send delay after voltage recovery [0..15] | unsignedInt 0…15 | 5 |
| Send cycle of In operation telegram [1..240,0=inactive] | unsignedInt 0…240 | 0 |
| Status object read request after restart | unsignedInt 0…1 | 1 |
| Input interface | unsignedInt 0…1 | 0 |
| Temperature calibration | list | 0.0 |
| Send temperature when the result change by | list | 1.0 |
| Cyclically send temperature [0...255,0=inactive] | unsignedInt 0…255 | 10 |
| Send alarm telegram for low/high temperature | list | No respond |
| Threshold value for low temperature alarm [0..15] | list | 0 |
| Threshold value for high temperature alarm [30..45] | list | 45 |
| Humidity calibration | list | 0 |
| Send humidity when the result change by [0..20,0=inactive] | unsignedInt 0…20 | 5 |
| Cyclically send humidity [0..255,0=inactive] | unsignedInt 0…255 | 10 |
| Send alarm telegram for low/high humidity | list | No respond |
| Threshold value for low humidity alarm [5..50] | unsignedInt 5…50 | 5 |
| Threshold value for high humidity alarm [55..85] | unsignedInt 55…85 | 85 |
| Function of input 1 | list | BI: Switch sensor |
| Function of input 2 | list | Disable |
| Description (max 30char.) | text | |
| B value of temperature sensor (must refer to the characteristic of component) | list | 3950 |
| Cyclically send temperature [0...255] | unsignedInt 0…255 | 0 |
| Reply error of sensor measurement | list | No respond |
| Object value of error | list | 0=no error/1=error |
| Lower threshold value for error report | list | 0 |
| Upper threshold value for error report | list | 60 |
| Distinction between short and long operation | list | No |
| Reaction on close the contact | list | TOGGLE |
| Reaction on open the contact | list | No reaction |
| Send object value after voltage recovery (valid if reaction is not toggle) | list | No |
| Number of objects | list | 1 |
| Long operation after [3..25] | unsignedInt 3…25 | 5 |
| Connected contact type | list | Normally open |
| Reaction on short operation | list | TOGGLE |
| Reaction on long operation | list | No reaction |
| Disable function | list | Disable |
| Reaction on close the contact | list | Recall scene |
| 8 bit scene number | list | Scene No.1 |
| Reaction on short operation | list | Recall scene |
| Reaction on close the contact | list | Send Value |
| String (14byte) value | text | Hello, world ! |
| Send object value after voltage recovery | list | No |
| Reaction on short operation | list | Send Value |
| Room temperature controller | unsignedInt 0…1 | 0 |
| Air Quality Level function | unsignedInt 0…1 | 0 |
| Air Quality controller | unsignedInt 0…1 | 0 |
| CO2 calibration | list | 0 |
| Send CO2 when the result change | list | 50 |
| Cyclically send CO2 [0..255,0=inactive] | unsignedInt 0…255 | 10 |
| Threshold value for low CO2 alarm [400..2000] | unsignedInt 400…2000 | 400 |
| Threshold value for high CO2 alarm [400..2000] | unsignedInt 400…2000 | 2000 |
| Report error when sensor failure | unsignedInt 0…1 | 0 |
| Send alarm telegram for low/high CO2 | list | No respond |
| RTC 1 | unsignedInt 0…1 | 0 |
| RTC 2 | unsignedInt 0…1 | 0 |
| RTC 3 | unsignedInt 0…1 | 0 |
| Relative humidity level function | list | Disable |
| Reference internal sensor | unsignedInt 0…1 | 1 |
| Number of reference external sensor | list | 0 |
| Number of reference external sensor | list | 1 |
| Calculation type | list | Weight average |
| Weighting of internal sensor | list | 50 |
| Weighting of external sensor 1 | list | 20 |
| Weighting of external sensor 2 | list | 20 |
| Weighting of external sensor 3 | list | 10 |
| Time period for request external sensor [0...255,0=inactive] | unsignedInt 0…255 | 10 |
| Send value when the result change by | list | 5 |
| Cyclically send value [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Control type | list | 1bit |
| Object datatype | list | 1byte percentage value |
| Cyclically send output value [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Hysteresis threshold value in +/- [1..10] | list | 5 |
| Send additional alarm message | unsignedInt 0…1 | 0 |
| Threshold value 1 for level 1 | unsignedInt 0…100 | 20 |
| Threshold value 2 for level 2 | unsignedInt 0…100 | 40 |
| Threshold value 3 for level 3 | unsignedInt 0…100 | 50 |
| Threshold value 4 for level 4 | unsignedInt 0…100 | 60 |
| If humidity value < threshold value 1, send | list | OFF |
| If humidity value >= threshold value 1, send | list | ON |
| If sensor failure, send | list | Nothing |
| If humidity value < threshold value 2, send | list | OFF |
| If humidity value >= threshold value 2, send | list | ON |
| If humidity value < threshold value 3, send | list | OFF |
| If humidity value >= threshold value 3, send | list | ON |
| If humidity value < threshold value 4, send | list | OFF |
| If humidity value >= threshold value 4, send | list | ON |
| Threshold value 1 (Level 1<->Level 2) | unsignedInt 0…100 | 20 |
| Threshold value 2 (Level 2<->Level 3) | unsignedInt 0…100 | 40 |
| Threshold value 3 (Level 3<->Level 4) | unsignedInt 0…100 | 50 |
| If humidity value < threshold value 1, send | list | Send value |
| Value | list | 0 |
| Value | unsignedInt 0…255 | 0 |
| Value | list | Scene No.1 |
| Value | color | #00FF00 |
| Alarm message | text | Alarm 1 |
| If threshold value 1 <= humidity value < threshold value 2, send | list | Send value |
| Value | list | 33 |
| Value | unsignedInt 0…255 | 1 |
| Value | list | Scene No.2 |
| Value | color | #FFFF00 |
| Alarm message | text | Alarm 2 |
| If threshold value 2 <= humidity value < threshold value 3, send | list | Send value |
| Value | list | 67 |
| Value | unsignedInt 0…255 | 2 |
| Value | list | Scene No.3 |
| Value | color | #FF8000 |
| Alarm message | text | Alarm 3 |
| If humidity value >= threshold value 3, send | list | Send value |
| Value | list | 100 |
| Value | unsignedInt 0…255 | 3 |
| Value | list | Scene No.4 |
| Value | color | #FF0000 |
| Alarm message | text | Alarm 4 |
| If humidity value >= threshold value 1, send | list | Send value |
| If humidity value >= threshold value 2, send | list | Send value |
| Value | list | Scene No.5 |
| CO2 level function | list | Disable |
| Send value when the result change by | list | 50 |
| Hysteresis threshold value in +/- [50..300] | unsignedInt 50…300 | 50 |
| Threshold value 1 for level 1 | unsignedInt 1…2000 | 350 |
| If CO2 value < threshold value 1, send | list | OFF |
| If CO2 value >= threshold value 1, send | list | ON |
| Threshold value 2 for level 2 | unsignedInt 1…2000 | 450 |
| If CO2 value < threshold value 2, send | list | OFF |
| If CO2 value >= threshold value 2, send | list | ON |
| Threshold value 3 for level 3 | unsignedInt 1…2000 | 1000 |
| If CO2 value < threshold value 3, send | list | OFF |
| If CO2 value >= threshold value 3, send | list | ON |
| Threshold value 4 for level 4 | unsignedInt 1…2000 | 1500 |
| If CO2 value < threshold value 4, send | list | OFF |
| If CO2 value >= threshold value 4, send | list | ON |
| Threshold value 1 (Level 1<->Level 2) | unsignedInt 1…2000 | 350 |
| Threshold value 2 (Level 2<->Level 3) | unsignedInt 1…2000 | 450 |
| Threshold value 3 (Level 3<->Level 4) | unsignedInt 1…2000 | 1000 |
| If CO2 value < threshold value 1, send | list | Send value |
| If threshold value 1 <= CO2 value < threshold value 2, send | list | Send value |
| If threshold value 2 <= CO2 value < threshold value 3, send | list | Send value |
| If CO2 value >= threshold value 3, send | list | Send value |
| Relative humidity controller function | list | Disable |
| Relative humidity reference from | list | Internal sensor |
| Combination ratio | list | 50% Internal to 50% External |
| Control type | list | 1byte |
| Cyclically send control value [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Control value for step 0 | list | 0 |
| Control value for step 0 | unsignedInt 0…255 | 0 |
| Control value for step 1 | list | 33 |
| Control value for step 1 | unsignedInt 0…255 | 1 |
| Control value for step 2 | list | 67 |
| Control value for step 2 | unsignedInt 0…255 | 2 |
| Control value for step 3 | list | 100 |
| Control value for step 3 | unsignedInt 0…255 | 3 |
| Threshold value 1 (step 0<->step 1) | unsignedInt 0…100 | 20 |
| Threshold value 2 (step 1<->step 2) | unsignedInt 0…100 | 40 |
| Threshold value 3 (step 2<->step 3) | unsignedInt 0…100 | 50 |
| Minimum time in step control [0..65535] | unsignedInt 0…65535 | 0 |
| If sensor failure, send | list | 0 |
| If sensor failure, send | unsignedInt 0…255 | 0 |
| Stop function | unsignedInt 0…1 | 0 |
| Controller automatically restart after [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Behaviour when controller off | list | Nothing |
| CO2 controller function | list | Disable |
| CO2 reference from | list | Internal sensor |
| Threshold value 1 (step 0<->step 1) | unsignedInt 1…2000 | 350 |
| Threshold value 2 (step 1<->step 2) | unsignedInt 1…2000 | 450 |
| Threshold value 3 (step 2<->step 3) | unsignedInt 1…2000 | 1000 |
| Setpoint CO2 value | unsignedInt 1…1500 | 500 |
| Setpoint value can be changed via bus | unsignedInt 0…1 | 0 |
| Proportional range | list | 100 |
| Reset time [15..240] | unsignedInt 15…240 | 15 |
| Minimum control value | list | 0 |
| Minimum control value | unsignedInt 0…255 | 0 |
| Maximum control value | list | 100 |
| Maximum control value | unsignedInt 0…255 | 255 |
| Sensor Failure Para display or not | unsignedInt 0…1 | 0 |
| Send value when the control value change by [0..100,0=inactive] | list | 5 |
| Send value when the control value change by [0..255,0=inactive] | unsignedInt 0…255 | 15 |
| Control value lower than the minimum value | list | 0%=0%, otherwise=Minimum value |
| Control value lower than the minimum value | list | 0=0, otherwise=Minimum value |
| Alarm function | unsignedInt 0…1 | 0 |
| Alarm tone time period | list | 10s |
| Alarm tone time automatically repeat interval time | list | 1min |
| Acknowledge from bus | list | Disable |
| Room temperature reference from | list | Internal sensor |
| Time period for request room temperature sensor [0...255] | unsignedInt 0…255 | 10 |
| Control value after temp. error[0..100] (if 2-point control, set value '0'=0, set value '>0'=1) | unsignedInt 0…100 | 0 |
| Room temperature control mode | list | Heating |
| Heating/Cooling switchover | list | Via object |
| Heating/Cooling status after download | list | Heating |
| Heating/Cooling status after voltage recovery | list | As before voltage failure |
| Room temperature control system | list | 4 pipes system |
| Operation mode | unsignedInt 0…1 | 0 |
| Initial setpoint temperature | list | 20.0 |
| Temperature error tip_setpoint/Max | unsignedInt 0…1 | 0 |
| Temperature error tip_setpoint/Min | unsignedInt 0…1 | 0 |
| Upper dead zone | list | 2.0 |
| Lower dead zone | list | 2.0 |
| Controller status after download | list | Comfort mode |
| Controller status after voltage recovery | list | As before voltage failure |
| Extended comfort mode [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| 1 bit object function for operation mode | unsignedInt 0…1 | 0 |
| 1 bit object for standby mode | unsignedInt 0…1 | 1 |
| Fan speed auto.control function | unsignedInt 0…1 | 0 |
| Window contact input function | unsignedInt 0…1 | 0 |
| Delay for window contact [0..65535] | unsignedInt 0…65535 | 15 |
| Controller mode for open window | list | Frost/heat protection |
| Bus presence detector function | unsignedInt 0…1 | 0 |
| Setpoint method for operating mode | list | Absolute |
| Base setpoint temperature | list | 20.0 |
| Additional setpoint offset for setpoint adjustment | list | Disable |
| Step of setpoint offset | list | 0.5K |
| Min. setpoint offset [-10..0] | signedInt -10…0 | -5 |
| Max. setpoint offset [0..10] | unsignedInt 0…10 | 5 |
| Reduced heating in standby mode [0..10] | list | 2 |
| Reduced heating in economy mode [0..10] | list | 4 |
| Setpoint temperature in frost protection mode [5..10] | list | 7 |
| Increased cooling in standby mode [0..10] | list | 2 |
| Increased cooling in economy mode [0..10] | list | 4 |
| Setpoint temperature in heat protection mode [30..37] | list | 35 |
| Min. setpoint temperature [5..37] | list | 11 |
| Max. setpoint temperature [5..37] | list | 32 |
| Setpoint temperature in comfort mode [5..37] | list | 21 |
| Setpoint temperature in standby mode [5..37] | list | 19 |
| Setpoint temperature in economy mode [5..37] | list | 17 |
| Setpoint temperature in comfort mode [5..37] | list | 23 |
| Setpoint temperature in standby mode [5..37] | list | 25 |
| Setpoint temperature in economy mode [5..37] | list | 27 |
| Minimum zone between heating and cooling setpoint | list | 2.0 |
| Type of heating control | list | Switching on/off(use 2-point control) |
| Invert control value | list | No |
| Lower Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| Upper Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| PWM cycle time [1..255] | unsignedInt 1…255 | 15 |
| Heating speed | list | Hot water heating(5K/150min) |
| Proportional range [10..100] | unsignedInt 0…100 | 40 |
| Reset time [0..255] | unsignedInt 0…255 | 150 |
| Send control value on change by [0..100,0=inactive] | unsignedInt 0…100 | 5 |
| Cyclically send control value [0..255] | unsignedInt 0…255 | 10 |
| Type of cooling control | list | Switching on/off(use 2-point control) |
| Cooling speed | list | Cooling ceiling (5K/240min) |
| Proportional range [10..100] | unsignedInt 10…100 | 40 |
| Type of heating/cooling control | list | Switching on/off(use 2-point control) |
| Auto. operation on object value | list | Auto=1/Man.=0 |
| Object datatype of 1byte fan speed | list | Percentage (DPT_5.001) |
| Output value for fan speed low | unsignedInt 1…255 | 1 |
| Output value for fan speed medium | unsignedInt 1…255 | 2 |
| Output value for fan speed high | unsignedInt 1…255 | 3 |
| Output value for fan speed low | unsignedInt 1…100 | 33 |
| Output value for fan speed medium | unsignedInt 1…100 | 67 |
| Output value for fan speed high | unsignedInt 1…100 | 100 |
| 1 bit object function for fan speed | unsignedInt 0…1 | 0 |
| 1 bit object for fan speed off | unsignedInt 0…1 | 0 |
| Threshold value speed OFF<-->low [1..255] | unsignedInt 1…255 | 80 |
| Threshold value speed low<-->medium [1..255] | unsignedInt 1…255 | 150 |
| Threshold value speed medium<-->high [1..255] | unsignedInt 1…255 | 200 |
| Hysteresis threshold value in +/-[0..50] | unsignedInt 0…50 | 10 |
| Temperature difference speed OFF<-->low [1..200] | unsignedInt 0…200 | 20 |
| Temperature difference speed low<-->medium [1..200] | unsignedInt 0…200 | 30 |
| Temperature difference speed medium<-->high [1..200] | unsignedInt 0…200 | 40 |
| Hysteresis temperature difference in [0..50] | unsignedInt 0…50 | 10 |
| Minimum time in fan speed [0..65535] | unsignedInt 0…65535 | 60 |
| Additional heating | unsignedInt 0…1 | 0 |
| Invert control value | unsignedInt 0…1 | 0 |
| Temperature difference to switch on additional heating [-100..-5] | signedInt -100…-5 | -25 |
| Hysteresis to switch off additional heating [-20..-1] | signedInt -20…-1 | -5 |
| Cyclically send control value [0..255] | unsignedInt 0…255 | 0 |
| Additional cooling | unsignedInt 0…1 | 0 |
| Temperature difference to switch on additional cooling [5..100] | unsignedInt 5…100 | 25 |
| Hysteresis to switch off additional cooling [1..20] | unsignedInt 1…20 | 5 |
| Additional heating/cooling | unsignedInt 0…1 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Temperature/Humidity/CO2 sensor with controller/1.0 1.0 latest | $009A | 3AB3 | 2026-11-25 | 190 KB | Download |
About this file
This is the official ETS product database for the GVS KNX CO2 sensor,55mm (CHAQ-03/55.2.0x), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from GVS
- CSBPC-02/00.1 1CSBPx17LB
- CSBP-02/00.x(x=2,3) 1S10xxC02S
- KNX Thermostat Lite,55mm CHTL-02/00.x.0y(x=1,2;y=0,1)
- KNX Motion Sensor,PIR CSBP-04/00.1.0x
- KNX Motion Sensor without brightness,PIR CSBP-04/00.2.0x
- KNX Presence Sensor,Microwave CSBPM-04/00.1.0x
- KNX Presence Sensor without brightness,Microwave CSBPM-04/00.2.0x
- KNX Dual Presence Sensor, PIR & Ultrasonic CSBPU-04/00.1.00
- Multifunctional Sensor CSMS-0x/00.1.0y
- KNX GPS Weather Station CSWS-04/00.1.00
- KNX GPS Weather Station Pro CSWSP-07/00.1.00
- KA/D 0203.1、KA/D 0215.S.1 1A02XXB02D