KNX Database
GVS CHTL-02/00.x.0y(x=1,2;y=0,1) KNX Thermostat Lite,55mm

KNX Thermostat Lite,55mm CHTL-02/00.x.0y(x=1,2;y=0,1)

GVS · Order number CHTL-02/00.x.0y(x=1,2;y=0,1) · Sensor › Air quality

Download .knxprod KNX Thermostat Lite,55mm/1.1 1.1 · 157 KB

Product

ManufacturerGVS
Product nameKNX Thermostat Lite,55mm
Order numberCHTL-02/00.x.0y(x=1,2;y=0,1)
HardwareKNX Thermostat Lite,55mm
MediumTwisted Pair
Bus current (mA)6
Rail mountedNo
RegistrationCertified · 2023-01-13
Languagesde-DE, en-US
Catalog entryM-0085_H-CH22JA-1_HP-0091-11-1588_CI-CHTL.2D02.2F00.2Ex.2E0y.28x.3D1.2C2.3By.3D0.2C1.29-1
Fingerprint1588
SHA-256a8a4f61fc18cdef65b6dae7f23179c0da3a9c2b6d1d8804ec2698f8e67cc98f3
First seen2026-11-25
Markets69 markets

Application program: KNX Thermostat Lite,55mm/1.1 1.1

Application number$0091
Version1.1
Mask versionMV-07B0 (System B)
KNX Data SecureYes
Minimum ETS version5.0
Parameters163
Group objects86
Group objects (86)
NoNameFunctionSizeDPTFlags
1GeneralIn operation1 Bit1.1 switchCRT
5Internal sensorTemperature value2 Bytes9.1 temperature (°C)CRT
6Internal sensorLow temperature alarm1 Bit1.5 alarmCRT
7Internal sensorHigh temperature alarm1 Bit1.5 alarmCRT
8Internal sensorHumidity value2 Bytes9.7 humidity (%)CRT
9Internal sensorLow humidity alarm1 Bit1.5 alarmCRT
10Internal sensorHigh humidity alarm1 Bit1.5 alarmCRT
11Input 1 - {{0:Temperature probe}}Actual temperature, Sensor2 Bytes9.1 temperature (°C)CRT
11Input 1 - {{0:Switch sensor}}Switch1 Bit1.1 switchCRWTU
11Input 1 - {{0:Switch sensor}}Close, Switch1 Bit1.1 switchCRWTU
11Input 1 - {{0:Switch sensor}}Short, Switch1 Bit1.1 switchCRWTU
11Input 1 - {{0:Scene control}}Scene1 Byte18.1 scene controlCT
11Input 1 - {{0:Scene control}}Close, Scene1 Byte18.1 scene controlCT
11Input 1 - {{0:Scene control}}Short, Scene1 Byte18.1 scene controlCT
11Input 1 - {{0:Send String}}String14 Bytes16.1 Character String (ISO 8859-1)CT
11Input 1 - {{0:Send String}}Close, String14 Bytes16.1 Character String (ISO 8859-1)CT
11Input 1 - {{0:Send String}}Short, String14 Bytes16.1 Character String (ISO 8859-1)CT
12Input 1 - {{0:Temperature probe}}Temperature error report, Sensor1 Bit1.5 alarmCRT
12Input 1 - {{0:Switch sensor}}Open, Switch1 Bit1.1 switchCRWTU
12Input 1 - {{0:Switch sensor}}Long, Switch1 Bit1.1 switchCRWTU
12Input 1 - {{0:Scene control}}Open, Scene1 Byte18.1 scene controlCT
12Input 1 - {{0:Scene control}}Long, Scene1 Byte18.1 scene controlCT
12Input 1 - {{0:Send String}}Open, String14 Bytes16.1 Character String (ISO 8859-1)CT
12Input 1 - {{0:Send String}}Long, String14 Bytes16.1 Character String (ISO 8859-1)CT
13Input 1 - {{0:Switch sensor}}Disable1 Bit1.3 enableCW
13Input 1 - {{0:Scene control}}Disable1 Bit1.3 enableCW
13Input 1 - {{0:Send String}}Disable1 Bit1.3 enableCW
14Input 2 - {{0:Temperature probe}}Actual temperature, Sensor2 Bytes9.1 temperature (°C)CRT
14Input 2 - {{0:Switch sensor}}Switch1 Bit1.1 switchCRWTU
14Input 2 - {{0:Switch sensor}}Close, Switch1 Bit1.1 switchCRWTU
14Input 2 - {{0:Switch sensor}}Short, Switch1 Bit1.1 switchCRWTU
14Input 2 - {{0:Scene control}}Scene1 Byte18.1 scene controlCT
14Input 2 - {{0:Scene control}}Close, Scene1 Byte18.1 scene controlCT
14Input 2 - {{0:Scene control}}Short, Scene1 Byte18.1 scene controlCT
14Input 2 - {{0:Send String}}String14 Bytes16.1 Character String (ISO 8859-1)CT
14Input 2 - {{0:Send String}}Close, String14 Bytes16.1 Character String (ISO 8859-1)CT
14Input 2 - {{0:Send String}}Short, String14 Bytes16.1 Character String (ISO 8859-1)CT
15Input 2 - {{0:Temperature probe}}Temperature error report, Sensor1 Bit1.5 alarmCRT
15Input 2 - {{0:Switch sensor}}Open, Switch1 Bit1.1 switchCRWTU
15Input 2 - {{0:Switch sensor}}Long, Switch1 Bit1.1 switchCRWTU
15Input 2 - {{0:Scene control}}Open, Scene1 Byte18.1 scene controlCT
15Input 2 - {{0:Scene control}}Long, Scene1 Byte18.1 scene controlCT
15Input 2 - {{0:Send String}}Open, String14 Bytes16.1 Character String (ISO 8859-1)CT
15Input 2 - {{0:Send String}}Long, String14 Bytes16.1 Character String (ISO 8859-1)CT
16Input 2 - {{0:Switch sensor}}Disable1 Bit1.3 enableCW
16Input 2 - {{0:Scene control}}Disable1 Bit1.3 enableCW
16Input 2 - {{0:Send String}}Disable1 Bit1.3 enableCW
17Room temperature controllerPower on/off 1 Bit1.1 switchCRW
18Room temperature controllerExternal temperature sensor2 Bytes9.1 temperature (°C)CWTU
19Room temperature controllerBase setpoint adjustment2 Bytes9.1 temperature (°C)CW
19Room temperature controllerCurrent setpoint adjustment2 Bytes9.1 temperature (°C)CW
20Room temperature controllerSetpoint offset1 Bit1.7 stepCW
21Room temperature controllerFloat offset value2 Bytes9.2 temperature difference (K)CW
22Room temperature controllerSetpoint offset reset1 Bit1.15 resetCW
23Room temperature controllerHeating/Cooling mode1 Bit1.100 cooling/heatingCW
24Room temperature controllerOperation mode1 Byte20.102 HVAC modeCW
25Room temperature controllerComfort mode1 Bit1.3 enableCW
26Room temperature controllerEconomy mode1 Bit1.3 enableCW
27Room temperature controllerFrost/Heat protection mode1 Bit1.3 enableCW
28Room temperature controllerStandby mode1 Bit1.3 enableCW
29Room temperature controllerExtended comfort mode1 Bit1.16 acknowledgeCW
30Room temperature controllerFan automatic operation1 Bit1.3 enableCW
31Room temperature controllerWindow contact1 Bit1.19 window/doorCWU
32Room temperature controllerPresence detector1 Bit1.18 occupancyCWU
33Room temperature controllerActual temperature, status2 Bytes9.1 temperature (°C)CRT
34Room temperature controllerBase temperature setpoint, status2 Bytes9.1 temperature (°C)CRT
35Room temperature controllerSetpoint offset, status2 Bytes9.2 temperature difference (K)CRT
36Room temperature controllerCurrent temperature setpoint, status2 Bytes9.1 temperature (°C)CRT
37Room temperature controllerHeating/Cooling mode, status1 Bit1.100 cooling/heatingCRT
38Room temperature controllerOperation mode, status1 Byte20.102 HVAC modeCRT
39Room temperature controllerComfort mode, status1 Bit1.3 enableCRT
40Room temperature controllerEconomy mode, status1 Bit1.3 enableCRT
41Room temperature controllerFrost/Heat protection mode, status1 Bit1.3 enableCRT
42Room temperature controllerStandby mode, status1 Bit1.3 enableCRT
43Room temperature controllerHeating control value1 Bit1.1 switchCRT
43Room temperature controllerHeating control value1 Byte5.1 percentage (0..100%)CRT
43Room temperature controllerHeating/Cooling control value1 Bit1.1 switchCRT
43Room temperature controllerHeating/Cooling control value1 Byte5.1 percentage (0..100%)CRT
44Room temperature controllerCooling control value1 Bit1.1 switchCRT
44Room temperature controllerCooling control value1 Byte5.1 percentage (0..100%)CRT
45Room temperature controllerFan speed1 Byte5.100 fan stage (0..255)CT
45Room temperature controllerFan speed1 Byte5.1 percentage (0..100%)CT
46Room temperature controllerFan speed low1 Bit1.1 switchCT
47Room temperature controllerFan speed medium1 Bit1.1 switchCT
48Room temperature controllerFan speed high1 Bit1.1 switchCT
49Room temperature controllerFan speed off1 Bit1.1 switchCT
Parameters (122)
ParameterTypeDefault
Send delay after voltage recovery [0..15]unsignedInt 0…155
Send cycle of In operation telegram [1..240,0=inactive]unsignedInt 0…2400
Status object read request after restartunsignedInt 0…11
Input interfaceunsignedInt 0…10
Temperature calibrationlist0.0
Send temperature when the result change bylist1.0K
Cyclically send temperature [0...255,0=inactive]unsignedInt 0…25510
Send alarm telegram for low/high temperaturelistNo respond
Threshold value for low temperature alarm [0..15]list0
Threshold value for high temperature alarm [30..45]list45
Humidity calibrationlist0
Send humidity when the result change by [0..20]unsignedInt 0…205
Cyclically send humidity [0..255,0=inactive]unsignedInt 0…25510
Send alarm telegram for low/high humiditylistNo respond
Threshold value for low humidity alarm [5..20]unsignedInt 5…205
Threshold value for high humidity alarm [70..85]unsignedInt 70…8585
Function of input 1listBI: Switch sensor
Function of input 2listDisable
Description (max 30char.)text
B value of temperature sensor (must refer to the characteristic of component)list3950
Cyclically send temperature [0...255]unsignedInt 0…2550
Reply error of sensor measurementlistNo respond
Object value of errorlist0=no error/1=error
Lower threshold value for error reportlist0
Upper threshold value for error reportlist60
Distinction between short and long operationlistNo
Reaction on close the contactlistTOGGLE
Reaction on open the contactlistNo reaction
Send object value after voltage recovery (valid if reaction is not toggle)listNo
Number of objectslist1
Long operation after [3..25]unsignedInt 3…255
Connected contact typelistNormally open
Reaction on short operationlistTOGGLE
Reaction on long operationlistNo reaction
Disable functionlistDisable
Reaction on close the contactlistRecall scene
8 bit scene numberlistScene No.1
Reaction on short operationlistRecall scene
Reaction on close the contactlistSend Value
String (14byte) valuetextHello, world !
Send object value after voltage recoverylistNo
Reaction on short operationlistSend Value
Room temperature controllerunsignedInt 0…10
Room temperature reference fromlistInternal sensor
Time period for request room temperature sensor [0...255]unsignedInt 0…25510
Combination ratiolist50% Internal to 50% External
Control value after temp. error[0..100] (if 2-point control, set value '0'=0, set value '>0'=1)unsignedInt 0…1000
Room temperature control modelistHeating
Heating/Cooling switchoverlistVia object
Heating/Cooling status after downloadlistHeating
Heating/Cooling status after voltage recoverylistAs before voltage failure
Room temperature control systemlist4 pipes system
Operation modeunsignedInt 0…10
Initial setpoint temperaturelist20.0
Upper dead zonelist2.0
Lower dead zonelist2.0
Controller status after downloadlistComfort mode
Controller status after voltage recoverylistAs before voltage failure
Extended comfort mode [0..255,0=inactive]unsignedInt 0…2550
1 bit object function for operation modeunsignedInt 0…10
1 bit object for standby modeunsignedInt 0…11
Fan speed auto.control functionunsignedInt 0…10
Window contact input functionunsignedInt 0…10
Delay for window contact [0..65535]unsignedInt 0…6553515
Controller mode for open windowlistFrost/heat protection
Bus presence detector functionunsignedInt 0…10
Setpoint method for operating modelistAbsolute
Base setpoint temperaturelist20.0
Additional setpoint offset for setpoint adjustmentlistDisable
Step of setpoint offsetlist0.5K
Min. setpoint offset [-10..0]signedInt -10…0-5
Max. setpoint offset [0..10]unsignedInt 0…105
Reduced heating in standby mode [0..10]list2
Reduced heating in economy mode [0..10]list4
Setpoint temperature in frost protection mode [5..10]list7
Increased cooling in standby mode [0..10]list2
Increased cooling in economy mode [0..10]list4
Setpoint temperature in heat protection mode [30..37]list35
Setpoint temperature in comfort mode [5..37]list21
Setpoint temperature in standby mode [5..37]list19
Setpoint temperature in economy mode [5..37]list17
Setpoint temperature in comfort mode [5..37]list23
Setpoint temperature in standby mode [5..37]list25
Setpoint temperature in economy mode [5..37]list27
Minimum zone between heating and cooling setpointlist2.0
Min. setpoint temperature [5..37]list16
Max. setpoint temperature [5..37]list32
Type of heating controllistSwitching on/off(use 2-point control)
Invert control valuelistNo
Lower Hysteresis [0..200]unsignedInt 0…20010
Upper Hysteresis [0..200]unsignedInt 0…20010
PWM cycle time [1..255]unsignedInt 1…25515
Heating speedlistHot water heating(5K/150min)
Proportional range [10..100]unsignedInt 0…10040
Reset time [0..255]unsignedInt 0…255150
Send control value on change by [0..100,0=inactive]unsignedInt 0…1004
Cyclically send control value [0..255]unsignedInt 0…25510
Type of cooling controllistSwitching on/off(use 2-point control)
Cooling speedlistCooling ceiling (5K/240min)
Proportional range [10..100]unsignedInt 10…10040
Type of heating/cooling controllistSwitching on/off(use 2-point control)
Auto. operation on object valuelistAuto=1/Man.=0
Object datatype of 1byte fan speedlistPercentage (DPT_5.001)
Output value for fan speed lowunsignedInt 1…2551
Output value for fan speed mediumunsignedInt 1…2552
Output value for fan speed highunsignedInt 1…2553
Output value for fan speed lowunsignedInt 1…10033
Output value for fan speed mediumunsignedInt 1…10067
Output value for fan speed highunsignedInt 1…100100
1 bit object function for fan speedunsignedInt 0…10
1 bit object for fan speed offunsignedInt 0…10
Threshold value speed OFF<-->low [1..255]unsignedInt 1…25580
Threshold value speed low<-->medium [1..255]unsignedInt 1…255150
Threshold value speed medium<-->high [1..255]unsignedInt 1…255200
Hysteresis threshold value in +/-[0..50]unsignedInt 0…5010
Temperature difference speed OFF<-->low [1..200]unsignedInt 0…20020
Temperature difference speed low<-->medium [1..200]unsignedInt 0…20030
Temperature difference speed medium<-->high [1..200]unsignedInt 0…20040
Hysteresis temperature difference in [0..50]unsignedInt 0…5010
Minimum time in fan speed [0..65535]unsignedInt 0…6553560
Temperature error tip_setpoint/MinunsignedInt 0…10
Temperature error tip_setpoint/MaxunsignedInt 0…10

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX Thermostat Lite,55mm/1.1 1.1 latest$009115882026-11-25157 KBDownload

About this file

This is the official ETS product database for the GVS KNX Thermostat Lite,55mm (CHTL-02/00.x.0y(x=1,2;y=0,1)), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from GVS