GWA9151
GEWISS · Order number GWA9151 · Actuators › Switching actuators, 4 outputs
Download .knxprod KNX Actuator 4 channels 16AX [SECURE] S 1.0 1.0 · 202 KB
Product
| Manufacturer | GEWISS |
|---|---|
| Product name | GWA9151 |
| Order number | GWA9151 |
| Product text | KNX Actuator 4 channels 16AX [SECURE] - DIN |
| Hardware | KNX Actuator 4 channels 16AX [SECURE] - DIN |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | Yes |
| Width (mm) | 72 |
| Registration | Certified · 2024-10-11 |
| Languages | en-US, de-DE, es-ES, it-IT |
| Catalog entry | M-0019_H-A9151-0_HP-5400-10-C4DF_CI-GWA9151-1 |
| Fingerprint | C4DF |
| SHA-256 | 76162b9348623bbd9592e033702e8db420e7168a8c7ba62b492d145400441c53 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: KNX Actuator 4 channels 16AX [SECURE] S 1.0 1.0
| Application number | $5400 |
|---|---|
| Version | 1.0 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | Yes |
| Minimum ETS version | 5.0 |
| Parameters | 615 |
| Group objects | 184 |
Group objects (184)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Ch.1 - Status | On/Off status | 1 Bit | 1.1 switch | CR |
| 1 | Ch.1 - Status | On/Off status | 1 Bit | 1.1 switch | CRT |
| 2 | Ch.1 - Switch | On/Off | 1 Bit | 1.1 switch | CW |
| 3 | Ch.1 - Delayed switching | On/Off | 1 Bit | 1.1 switch | CW |
| 4 | Ch.1 - Delay on activation | Set value | 2 Bytes | 7.5 time (s) | CW |
| 5 | Ch.1 - Delay on deactivation | Set value | 2 Bytes | 7.5 time (s) | CW |
| 6 | Ch.1 - Timed switch | Start/Stop | 1 Bit | 1.10 start/stop | CW |
| 7 | Ch.1 - Stairs light activation time | Set value | 2 Bytes | 7.5 time (s) | CW |
| 8 | Ch.1 - Blinking | Switching On/Off | 1 Bit | 1.1 switch | CW |
| 9 | Ch.1 - Scene | Execute/Store | 1 Byte | 18.1 scene control | CW |
| 10 | Ch.1 - Scene storing enabling | Switching On/Off | 1 Bit | 1.3 enable | CW |
| 11 | Ch.1 - Logic input 1 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 12 | Ch.1 - Logic input 2 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 13 | Ch.1 - Logic input 3 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 14 | Ch.1 - Logic input 4 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 15 | Ch.1 - Logic input 5 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 16 | Ch.1 - Logic input 6 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 17 | Ch.1 - Logic input 7 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 18 | Ch.1 - Logic input 8 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 19 | Ch.1 - Logical operation outcome | Logic | 1 Bit | 1.2 boolean | CRT |
| 20 | Ch.1 - Enable loads control slave function | Enable/Disable | 1 Bit | 1.2 boolean | CW |
| 21 | Ch.1 - Loads control slave function enabling status | Switching On/Off | 1 Bit | 1.3 enable | CRT |
| 22 | Ch.1 - Slave switching for loads control | 1=Load lock/0=Load unlock | 1 Bit | 1.1 switch | CW |
| 23 | Ch.1 - Slave status for loads control | 1=Locked/0=Unlocked | 1 Bit | 1.1 switch | CRT |
| 24 | Ch.1 - Safety | Monitoring | 1 Bit | 1.2 boolean | CW |
| 25 | Ch.1 - Safety status | Switching On/Off | 1 Bit | 1.3 enable | CRT |
| 26 | Ch.1 - Priority command | On/Off forced positioning | 2 Bit | 2.1 switch control | CW |
| 27 | Ch.1 - Priority command status | On/Off forced positioning status | 2 Bit | 2.1 switch control | CRT |
| 28 | Ch.1 - Block | Switching On/Off | 1 Bit | 1.2 boolean | CW |
| 29 | Ch.1 - Block status | Active/Not active | 1 Bit | 1.3 enable | CRT |
| 30 | Ch.1 - Operating time counter | Value 0 .. 2147483647 [s] | 4 Bytes | 13.100 time lag (s) | CRT |
| 30 | Ch.1 - Operating time counter | Value 0 .. 65535 [min] | 2 Bytes | 7.6 time (min) | CRT |
| 30 | Ch.1 - Operating time counter | Value 0 .. 65535 [h] | 2 Bytes | 7.7 time (h) | CRT |
| 30 | Ch.1 - Operating time counter | Value 0 .. 2147483647 [s] | 4 Bytes | 13.100 time lag (s) | CR |
| 30 | Ch.1 - Operating time counter | Value 0 .. 65535 [min] | 2 Bytes | 7.6 time (min) | CR |
| 30 | Ch.1 - Operating time counter | Value 0 .. 65535 [h] | 2 Bytes | 7.7 time (h) | CR |
| 31 | Ch.1 - Operating time counter overflow | Overflow status | 1 Bit | 1.2 boolean | CRT |
| 32 | Ch.1 - Operating time counter reset | 1=Reset/0=No action | 1 Bit | 1.15 reset | CW |
| 33 | Ch.1 - Switching operation counter | Value 0 .. 4294967295 | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 33 | Ch.1 - Switching operation counter | Value 0 .. 65535 | 2 Bytes | 7.1 pulses | CRT |
| 33 | Ch.1 - Switching operation counter | Value 0 .. 65535 | 2 Bytes | 7.1 pulses | CR |
| 33 | Ch.1 - Switching operation counter | Value 0 .. 4294967295 | 4 Bytes | 12.1 counter pulses (unsigned) | CR |
| 34 | Ch.1 - Switching operation counter overflow | Overflow status | 1 Bit | 1.2 boolean | CRT |
| 35 | Ch.1 - Switching operation counter reset | 1=Reset/0=No action | 1 Bit | 1.15 reset | CW |
| 36 | Ch.1 - Local button function enabling status | Enabled/Disabled | 1 Bit | 1.3 enable | CRT |
| 37 | Ch.1 - Local button function enabling | Enable/Disable | 1 Bit | 1.3 enable | CW |
| 38 | Ch.2 - Status | On/Off status | 1 Bit | 1.1 switch | CRT |
| 38 | Ch.2 - Status | On/Off status | 1 Bit | 1.1 switch | CR |
| 39 | Ch.2 - Switch | On/Off | 1 Bit | 1.1 switch | CW |
| 40 | Ch.2 - Delayed switching | On/Off | 1 Bit | 1.1 switch | CW |
| 41 | Ch.2 - Delay on activation | Set value | 2 Bytes | 7.5 time (s) | CW |
| 42 | Ch.2 - Delay on deactivation | Set value | 2 Bytes | 7.5 time (s) | CW |
| 43 | Ch.2 - Timed switch | Start/Stop | 1 Bit | 1.10 start/stop | CW |
| 44 | Ch.2 - Stairs light activation time | Set value | 2 Bytes | 7.5 time (s) | CW |
| 45 | Ch.2 - Blinking | Switching On/Off | 1 Bit | 1.1 switch | CW |
| 46 | Ch.2 - Scene | Execute/Store | 1 Byte | 18.1 scene control | CW |
| 47 | Ch.2 - Scene storing enabling | Switching On/Off | 1 Bit | 1.3 enable | CW |
| 48 | Ch.2 - Logic input 1 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 49 | Ch.2 - Logic input 2 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 50 | Ch.2 - Logic input 3 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 51 | Ch.2 - Logic input 4 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 52 | Ch.2 - Logic input 5 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 53 | Ch.2 - Logic input 6 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 54 | Ch.2 - Logic input 7 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 55 | Ch.2 - Logic input 8 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 56 | Ch.2 - Logical operation outcome | Logic | 1 Bit | 1.2 boolean | CRT |
| 57 | Ch.2 - Enable loads control slave function | Enable/Disable | 1 Bit | 1.2 boolean | CW |
| 58 | Ch.2 - Loads control slave function enabling status | Switching On/Off | 1 Bit | 1.3 enable | CRT |
| 59 | Ch.2 - Slave switching for loads control | 1=Load lock/0=Load unlock | 1 Bit | 1.1 switch | CW |
| 60 | Ch.2 - Slave status for loads control | 1=Locked/0=Unlocked | 1 Bit | 1.1 switch | CRT |
| 61 | Ch.2 - Safety | Monitoring | 1 Bit | 1.2 boolean | CW |
| 62 | Ch.2 - Safety status | Switching On/Off | 1 Bit | 1.3 enable | CRT |
| 63 | Ch.2 - Priority command | On/Off forced positioning | 2 Bit | 2.1 switch control | CW |
| 64 | Ch.2 - Priority command status | On/Off forced positioning status | 2 Bit | 2.1 switch control | CRT |
| 65 | Ch.2 - Block | Switching On/Off | 1 Bit | 1.2 boolean | CW |
| 66 | Ch.2 - Block status | Active/Not active | 1 Bit | 1.3 enable | CRT |
| 67 | Ch.2 - Operating time counter | Value 0 .. 2147483647 [s] | 4 Bytes | 13.100 time lag (s) | CRT |
| 67 | Ch.2 - Operating time counter | Value 0 .. 65535 [min] | 2 Bytes | 7.6 time (min) | CRT |
| 67 | Ch.2 - Operating time counter | Value 0 .. 65535 [h] | 2 Bytes | 7.7 time (h) | CRT |
| 67 | Ch.2 - Operating time counter | Value 0 .. 2147483647 [s] | 4 Bytes | 13.100 time lag (s) | CR |
| 67 | Ch.2 - Operating time counter | Value 0 .. 65535 [min] | 2 Bytes | 7.6 time (min) | CR |
| 67 | Ch.2 - Operating time counter | Value 0 .. 65535 [h] | 2 Bytes | 7.7 time (h) | CR |
| 68 | Ch.2 - Operating time counter overflow | Overflow status | 1 Bit | 1.2 boolean | CRT |
| 69 | Ch.2 - Operating time counter reset | 1=Reset/0=No action | 1 Bit | 1.15 reset | CW |
| 70 | Ch.2 - Switching operation counter | Value 0 .. 4294967295 | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 70 | Ch.2 - Switching operation counter | Value 0 .. 65535 | 2 Bytes | 7.1 pulses | CRT |
| 70 | Ch.2 - Switching operation counter | Value 0 .. 65535 | 2 Bytes | 7.1 pulses | CR |
| 70 | Ch.2 - Switching operation counter | Value 0 .. 4294967295 | 4 Bytes | 12.1 counter pulses (unsigned) | CR |
| 71 | Ch.2 - Switching operation counter overflow | Overflow status | 1 Bit | 1.2 boolean | CRT |
| 72 | Ch.2 - Switching operation counter reset | 1=Reset/0=No action | 1 Bit | 1.15 reset | CW |
| 73 | Ch.2 - Local button function enabling status | Enabled/Disabled | 1 Bit | 1.3 enable | CRT |
| 74 | Ch.2 - Local button function enabling | Enable/Disable | 1 Bit | 1.3 enable | CW |
| 75 | Ch.3 - Status | On/Off status | 1 Bit | 1.1 switch | CRT |
| 75 | Ch.3 - Status | On/Off status | 1 Bit | 1.1 switch | CR |
| 76 | Ch.3 - Switch | On/Off | 1 Bit | 1.1 switch | CW |
| 77 | Ch.3 - Delayed switching | On/Off | 1 Bit | 1.1 switch | CW |
| 78 | Ch.3 - Delay on activation | Set value | 2 Bytes | 7.5 time (s) | CW |
| 79 | Ch.3 - Delay on deactivation | Set value | 2 Bytes | 7.5 time (s) | CW |
| 80 | Ch.3 - Timed switch | Start/Stop | 1 Bit | 1.10 start/stop | CW |
| 81 | Ch.3 - Stairs light activation time | Set value | 2 Bytes | 7.5 time (s) | CW |
| 82 | Ch.3 - Blinking | Switching On/Off | 1 Bit | 1.1 switch | CW |
| 83 | Ch.3 - Scene | Execute/Store | 1 Byte | 18.1 scene control | CW |
| 84 | Ch.3 - Scene storing enabling | Switching On/Off | 1 Bit | 1.3 enable | CW |
| 85 | Ch.3 - Logic input 1 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 86 | Ch.3 - Logic input 2 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 87 | Ch.3 - Logic input 3 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 88 | Ch.3 - Logic input 4 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 89 | Ch.3 - Logic input 5 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 90 | Ch.3 - Logic input 6 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 91 | Ch.3 - Logic input 7 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 92 | Ch.3 - Logic input 8 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 93 | Ch.3 - Logical operation outcome | Logic | 1 Bit | 1.2 boolean | CRT |
| 94 | Ch.3 - Enable loads control slave function | Enable/Disable | 1 Bit | 1.2 boolean | CW |
| 95 | Ch.3 - Loads control slave function enabling status | Switching On/Off | 1 Bit | 1.3 enable | CRT |
| 96 | Ch.3 - Slave switching for loads control | 1=Load lock/0=Load unlock | 1 Bit | 1.1 switch | CW |
| 97 | Ch.3 - Slave status for loads control | 1=Locked/0=Unlocked | 1 Bit | 1.1 switch | CRT |
| 98 | Ch.3 - Safety | Monitoring | 1 Bit | 1.2 boolean | CW |
| 99 | Ch.3 - Safety status | Switching On/Off | 1 Bit | 1.3 enable | CRT |
| 100 | Ch.3 - Priority command | On/Off forced positioning | 2 Bit | 2.1 switch control | CW |
| 101 | Ch.3 - Priority command status | On/Off forced positioning status | 2 Bit | 2.1 switch control | CRT |
| 102 | Ch.3 - Block | Switching On/Off | 1 Bit | 1.2 boolean | CW |
| 103 | Ch.3 - Block status | Active/Not active | 1 Bit | 1.3 enable | CRT |
| 104 | Ch.3 - Operating time counter | Value 0 .. 2147483647 [s] | 4 Bytes | 13.100 time lag (s) | CRT |
| 104 | Ch.3 - Operating time counter | Value 0 .. 65535 [min] | 2 Bytes | 7.6 time (min) | CRT |
| 104 | Ch.3 - Operating time counter | Value 0 .. 65535 [h] | 2 Bytes | 7.7 time (h) | CRT |
| 104 | Ch.3 - Operating time counter | Value 0 .. 2147483647 [s] | 4 Bytes | 13.100 time lag (s) | CR |
| 104 | Ch.3 - Operating time counter | Value 0 .. 65535 [min] | 2 Bytes | 7.6 time (min) | CR |
| 104 | Ch.3 - Operating time counter | Value 0 .. 65535 [h] | 2 Bytes | 7.7 time (h) | CR |
| 105 | Ch.3 - Operating time counter overflow | Overflow status | 1 Bit | 1.2 boolean | CRT |
| 106 | Ch.3 - Operating time counter reset | 1=Reset/0=No action | 1 Bit | 1.15 reset | CW |
| 107 | Ch.3 - Switching operation counter | Value 0 .. 4294967295 | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 107 | Ch.3 - Switching operation counter | Value 0 .. 65535 | 2 Bytes | 7.1 pulses | CRT |
| 107 | Ch.3 - Switching operation counter | Value 0 .. 65535 | 2 Bytes | 7.1 pulses | CR |
| 107 | Ch.3 - Switching operation counter | Value 0 .. 4294967295 | 4 Bytes | 12.1 counter pulses (unsigned) | CR |
| 108 | Ch.3 - Switching operation counter overflow | Overflow status | 1 Bit | 1.2 boolean | CRT |
| 109 | Ch.3 - Switching operation counter reset | 1=Reset/0=No action | 1 Bit | 1.15 reset | CW |
| 110 | Ch.3 - Local button function enabling status | Enabled/Disabled | 1 Bit | 1.3 enable | CRT |
| 111 | Ch.3 - Local button function enabling | Enable/Disable | 1 Bit | 1.3 enable | CW |
| 112 | Ch.4 - Status | On/Off status | 1 Bit | 1.1 switch | CRT |
| 112 | Ch.4 - Status | On/Off status | 1 Bit | 1.1 switch | CR |
| 113 | Ch.4 - Switch | On/Off | 1 Bit | 1.1 switch | CW |
| 114 | Ch.4 - Delayed switching | On/Off | 1 Bit | 1.1 switch | CW |
| 115 | Ch.4 - Delay on activation | Set value | 2 Bytes | 7.5 time (s) | CW |
| 116 | Ch.4 - Delay on deactivation | Set value | 2 Bytes | 7.5 time (s) | CW |
| 117 | Ch.4 - Timed switch | Start/Stop | 1 Bit | 1.10 start/stop | CW |
| 118 | Ch.4 - Stairs light activation time | Set value | 2 Bytes | 7.5 time (s) | CW |
| 119 | Ch.4 - Blinking | Switching On/Off | 1 Bit | 1.1 switch | CW |
| 120 | Ch.4 - Scene | Execute/Store | 1 Byte | 18.1 scene control | CW |
| 121 | Ch.4 - Scene storing enabling | Switching On/Off | 1 Bit | 1.3 enable | CW |
| 122 | Ch.4 - Logic input 1 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 123 | Ch.4 - Logic input 2 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 124 | Ch.4 - Logic input 3 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 125 | Ch.4 - Logic input 4 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 126 | Ch.4 - Logic input 5 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 127 | Ch.4 - Logic input 6 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 128 | Ch.4 - Logic input 7 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 129 | Ch.4 - Logic input 8 | Logic function input | 1 Bit | 1.2 boolean | CWTU |
| 130 | Ch.4 - Logical operation outcome | Logic | 1 Bit | 1.2 boolean | CRT |
| 131 | Ch.4 - Enable loads control slave function | Enable/Disable | 1 Bit | 1.2 boolean | CW |
| 132 | Ch.4 - Loads control slave function enabling status | Switching On/Off | 1 Bit | 1.3 enable | CRT |
| 133 | Ch.4 - Slave switching for loads control | 1=Load lock/0=Load unlock | 1 Bit | 1.1 switch | CW |
| 134 | Ch.4 - Slave status for loads control | 1=Locked/0=Unlocked | 1 Bit | 1.1 switch | CRT |
| 135 | Ch.4 - Safety | Monitoring | 1 Bit | 1.2 boolean | CW |
| 136 | Ch.4 - Safety status | Switching On/Off | 1 Bit | 1.3 enable | CRT |
| 137 | Ch.4 - Priority command | On/Off forced positioning | 2 Bit | 2.1 switch control | CW |
| 138 | Ch.4 - Priority command status | On/Off forced positioning status | 2 Bit | 2.1 switch control | CRT |
| 139 | Ch.4 - Block | Switching On/Off | 1 Bit | 1.2 boolean | CW |
| 140 | Ch.4 - Block status | Active/Not active | 1 Bit | 1.3 enable | CRT |
| 141 | Ch.4 - Operating time counter | Value 0 .. 2147483647 [s] | 4 Bytes | 13.100 time lag (s) | CRT |
| 141 | Ch.4 - Operating time counter | Value 0 .. 65535 [min] | 2 Bytes | 7.6 time (min) | CRT |
| 141 | Ch.4 - Operating time counter | Value 0 .. 65535 [h] | 2 Bytes | 7.7 time (h) | CRT |
| 141 | Ch.4 - Operating time counter | Value 0 .. 2147483647 [s] | 4 Bytes | 13.100 time lag (s) | CR |
| 141 | Ch.4 - Operating time counter | Value 0 .. 65535 [min] | 2 Bytes | 7.6 time (min) | CR |
| 141 | Ch.4 - Operating time counter | Value 0 .. 65535 [h] | 2 Bytes | 7.7 time (h) | CR |
| 142 | Ch.4 - Operating time counter overflow | Overflow status | 1 Bit | 1.2 boolean | CRT |
| 143 | Ch.4 - Operating time counter reset | 1=Reset/0=No action | 1 Bit | 1.15 reset | CW |
| 144 | Ch.4 - Switching operation counter | Value 0 .. 4294967295 | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 144 | Ch.4 - Switching operation counter | Value 0 .. 65535 | 2 Bytes | 7.1 pulses | CRT |
| 144 | Ch.4 - Switching operation counter | Value 0 .. 65535 | 2 Bytes | 7.1 pulses | CR |
| 144 | Ch.4 - Switching operation counter | Value 0 .. 4294967295 | 4 Bytes | 12.1 counter pulses (unsigned) | CR |
| 145 | Ch.4 - Switching operation counter overflow | Overflow status | 1 Bit | 1.2 boolean | CRT |
| 146 | Ch.4 - Switching operation counter reset | 1=Reset/0=No action | 1 Bit | 1.15 reset | CW |
| 147 | Ch.4 - Local button function enabling status | Enabled/Disabled | 1 Bit | 1.3 enable | CRT |
| 148 | Ch.4 - Local button function enabling | Enable/Disable | 1 Bit | 1.3 enable | CW |
Parameters (153)
| Parameter | Type | Default |
|---|---|---|
| PID_HARDWARE_TYPE_PARAMETER | list | |
| Channel 1 | list | disable |
| Channel 2 | list | disable |
| Channel 3 | list | disable |
| Channel 4 | list | disable |
| PARAM_DO_MASTER_RESET | list | APP_FIRST_BOOT |
| Transmission delay after start | list | 11.. 21 seconds (depending on physical address) |
| Channel 1 local button function | list | on/off switching |
| - Sending on pressing detection | list | cyclical switching |
| - Sending on release detection | list | no effect |
| - Sending on pressing detection | list | timing start |
| - Scene number (0.. 63) | unsignedInt 0…63 | 0 |
| - Scene storing on long operation | list | enable |
| - Sending on pressing detection | list | active on forcing |
| - Sending on pressing detection | list | activation |
| - Activate/deactivate local button operation from bus | list | disable |
| Channel 2 local button function | list | on/off switching |
| Channel 3 local button function | list | on/off switching |
| Channel 4 local key function | list | on/off switching |
| Delay on activation/deactivation function | list | deactivated |
| Stairs light function | list | deactivated |
| Blinking function | list | deactivated |
| Scenes function | list | deactivated |
| Logic function | list | deactivated |
| Load control - slave function | list | deactivated |
| Safety function | list | deactivated |
| Forced positioning function | list | deactivated |
| Block function | list | deactivated |
| Counter function | list | deactivated |
| Contact type | list | normally open (NO) |
| Status information transmission | list | sending on change |
| - Status transmission on bus voltage recovery | list | enable |
| Relay status after application download | list | open (with NO)/closed (with NC) |
| Relay status at bus voltage failure | list | no change |
| Relay status after bus voltage recovery | list | as before voltage drop |
| Mode activation value | list | "1" value |
| Delay on switching on [hours] | unsignedInt 0…24 | 0 |
| Delay on switching on [minutes] | unsignedInt 0…59 | 0 |
| Delay on switching on [seconds] | unsignedInt 0…59 | 5 |
| Retriggerable delay on activation | list | no |
| Delay setting for switching on from bus | list | disable |
| Delay on deactivation [hours] | unsignedInt 0…24 | 0 |
| Delay on deactivation [minutes] | unsignedInt 0…59 | 0 |
| Delay on deactivation [seconds] | unsignedInt 0…59 | 5 |
| Retriggerable delay on deactivation | list | no |
| Delay setting for switching off from bus | list | disable |
| Activation time [hours] | unsignedInt 0…24 | 0 |
| Activation time [minutes] | unsignedInt 0…59 | 1 |
| Activation time [seconds] | unsignedInt 0…59 | 0 |
| Delay on timed activation | list | disable |
| - Timed activation delay length | list | 1 s |
| Prewarning time | list | disable |
| - Prewarning time length | list | 15 s |
| - Load deactivation duration | unsignedInt 5…15 | 5 |
| Timing stop function | list | disable |
| Command of activation during timing | list | restart |
| - Multiplicative factor maximum value | unsignedInt 2…5 | 5 |
| Stairs light activation time setting from bus | list | disable |
| Activation time [minutes] | unsignedInt 0…59 | 0 |
| Activation time [seconds] | unsignedInt 0…59 | 5 |
| Deactivation time [hours] | unsignedInt 0…24 | 0 |
| Deactivation time [minutes] | unsignedInt 0…59 | 0 |
| Deactivation time [seconds] | unsignedInt 0…59 | 5 |
| Relay status on switching blinking mode off | list | no change |
| Blinking mode on bus voltage recovery | list | as before voltage drop |
| Scene number 1 | list | unassigned |
| Scene 1 relay start status | list | open (with NO)/closed (with NC) |
| Scene number 2 | list | unassigned |
| Scene 2 relay start status | list | open (with NO)/closed (with NC) |
| Scene number 3 | list | unassigned |
| Scene 3 relay start status | list | open (with NO)/closed (with NC) |
| Scene number 4 | list | unassigned |
| Scene 4 relay start status | list | open (with NO)/closed (with NC) |
| Scene number 5 | list | unassigned |
| Scene 5 relay start status | list | open (with NO)/closed (with NC) |
| Scene number 6 | list | unassigned |
| Scene 6 relay start status | list | open (with NO)/closed (with NC) |
| Scene number 7 | list | unassigned |
| Scene 7 relay start status | list | open (with NO)/closed (with NC) |
| Scene number 8 | list | unassigned |
| Scene 8 relay start status | list | open (with NO)/closed (with NC) |
| Scenes storing enabling | list | enable |
| Logic inputs number | list | 1 |
| Operation between logic inputs | list | AND |
| The outcome of the operation with logic inputs stands for | list | new logic input |
| Execute logical operation with the object | list | switching |
| Logical operation to execute | list | AND |
| Switching (on/off) commands | list | independent from logic function |
| Delayed switching commands | list | independent from logic function |
| Timed activation commands | list | independent from logic function |
| Blinking switching on/off commands | list | independent from logic function |
| Scene commands | list | independent from logic function |
| NOT operation for logic input 1 | list | disable |
| Logic input 1 value at download | list | "0" value |
| Logic input 1 value at bus voltage recovery | list | as before voltage drop |
| NOT operation for logic input 2 | list | disable |
| Logic input 2 value at download | list | "0" value |
| Logic input 2 value at bus voltage recovery | list | as before voltage drop |
| NOT operation for logic input 3 | list | disable |
| Logic input 3 value at download | list | "0" value |
| Logic input 3 value at bus voltage recovery | list | as before voltage drop |
| NOT operation for logic input 4 | list | disable |
| Logic input 4 value at download | list | "0" value |
| Logic input 4 value at bus voltage recovery | list | as before voltage drop |
| NOT operation for logic input 5 | list | disable |
| Logic input 5 value at download | list | "0" value |
| Logic input 5 value at bus voltage recovery | list | as before voltage drop |
| NOT operation for logic input 6 | list | disable |
| Logic input 6 value at download | list | "0" value |
| Logic input 6 value at bus voltage recovery | list | as before voltage drop |
| NOT operation for logic input 7 | list | disable |
| Logic input 7 value at download | list | "0" value |
| Logic input 7 value at bus voltage recovery | list | as before voltage drop |
| NOT operation for logic input 8 | list | disable |
| Logic input 8 value at download | list | "0" value |
| Logic input 8 value at bus voltage recovery | list | as before voltage drop |
| Logic function outcome feedback | list | disabled |
| Load control slave function activation value | list | "1" value |
| Relay status following load reconnection command | list | follows last command received |
| Loads control function on download | list | deactivated |
| Loads control function at bus voltage recovery | list | as before voltage drop |
| Control method | list | periodic transmission absence |
| Relay status on safety | list | open (with NO)/closed (with NC) |
| Relay status after safety | list | follows last command received |
| Monitoring time [hours] | unsignedInt 0…24 | 0 |
| Monitoring time [minutes] | unsignedInt 0…59 | 5 |
| Monitoring time [seconds] | unsignedInt 0…59 | 0 |
| Safety on bus tension recovery function | list | as before voltage drop |
| Relay status on forced positioning end | list | follows last command received |
| Forcing status on bus voltage recovery | list | as before voltage drop |
| Block activation value | list | "1" value |
| Relay status on active block | list | open (with NO)/closed (with NC) |
| Relay status on block deactivation | list | follows last command received |
| Block on download function | list | deactivated |
| Block on bus tension recovery function | list | as before voltage drop |
| Increase the operating time counter value if | list | contact is closed |
| Operating time counter value format | list | 4 bytes (seconds) |
| Overflow value | unsignedInt 0…2147483647 | 2147483647 |
| Overflow value | unsignedInt 0…65535 | 65535 |
| Counter value sending condition | list | send in case of change |
| - Minimum counter variation for sending value | unsignedInt 1…100 | 10 |
| - Counter sending period | unsignedInt 1…255 | 15 |
| PARAM_CH_1_PERIOD_COUNTER_RESET_OBJECT | list | deactivated |
| Switching operations counter value format | list | 4 bytes unsigned values |
| Overflow value | unsignedInt 0…4294967295 | 4294967295 |
| PARAM_CH_1_HANDLE_COUNTER_RESET_OBJECT | list | deactivated |
| PARAM_CH_2_PERIOD_COUNTER_RESET_OBJECT | list | deactivated |
| PARAM_CH_2_HANDLE_COUNTER_RESET_OBJECT | list | deactivated |
| PARAM_CH_3_PERIOD_COUNTER_RESET_OBJECT | list | deactivated |
| PARAM_CH_3_HANDLE_COUNTER_RESET_OBJECT | list | deactivated |
| PARAM_CH_4_PERIOD_COUNTER_RESET_OBJECT | list | deactivated |
| PARAM_CH_4_HANDLE_COUNTER_RESET_OBJECT | list | deactivated |
| The logic input value stands for | list | new logic input |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX Actuator 4 channels 16AX [SECURE] S 1.0 1.0 latest | $5400 | C4DF | 2026-11-25 | 202 KB | Download |
About this file
This is the official ETS product database for the GEWISS GWA9151 (GWA9151), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.