KNX Database

GW12796

GEWISS · Order number GW12796 · Actuators › Dispositivi di uscita binari, 1ch

Download .knxprod Switch actuator 1 ch. 16A S 1.1 1.1 · 80 KB

Product

ManufacturerGEWISS
Product nameGW12796
Order numberGW12796
Product textSwitch actuator 1 ch. 16A - black
HardwareAttuatore 1 canale 16A
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified · 2020-12-04
Languagesde-DE, en-US, es-ES, it-IT
Catalog entryM-0019_H-10796-1_HP-5106-11-0721_CI-GW12796-1
Fingerprint0721
SHA-256c0a88eda2d6c945c5421ec051b3ef6734f94f83520674ecd22943a042bd75615
First seen2026-11-25
Markets59 markets

Application program: Switch actuator 1 ch. 16A S 1.1 1.1

Application number$5106
Version1.1
Mask versionMV-0021 (2.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters92
Group objects11
Group objects (11)
NoNameFunctionSizeDPTFlags
0StatusOn/Off status1 Bit1.1 switchCRT
1SwitchingOn/Off1 Bit1.2 booleanCW
2Priority commandOn/Off forced positioning2 Bit2.1 switch controlCW
3Logical 1Logic1 Bit1.2 booleanCW
4Logical 2Logic1 Bit1.2 booleanCW
5Logical 3Logic1 Bit1.2 booleanCW
6Logical 4Logic1 Bit1.2 booleanCW
7SafetyMonitoring1 Bit1.2 booleanCW
8SceneExecute/Store1 Byte18.1 scene controlCW
9BlockSwitching On/Off1 Bit1.2 booleanCW
10Activation timeTiming2 Bytes9.10 time (s)CW
Parameters (82)
ParameterTypeDefault
RESET_VALUElistzero
Operating modelistswitching ON/OFF
Mode activation valuelist"1" value
Status feedback sendinglistoff
Local pushbutton behaviourlistcyclical switching (On/Off)
Night lightinglistactive
Relay status on bus voltage droplistopen (with NO) / closed (with NC)
Relay status on bus voltage recoverylistopen (with NO) / closed (with NC)
Delay on activation functionlistdeactivated
Delay on activation [hours]unsignedInt 0…240
Delay on activation [minutes]unsignedInt 0…590
Delay on activation [seconds]unsignedInt 0…595
Resettable delay on activationlistno
Delay function on deactivationlistdeactivated
Delay on deactivation [hours]unsignedInt 0…240
Delay on deactivation [minutes]unsignedInt 0…590
Delay on deactivation [seconds]unsignedInt 0…595
Resettable delay on deactivationlistno
Stairs light timing [hours]unsignedInt 0…240
Stairs light timing [minutes]unsignedInt 0…590
Stairs light timing [seconds]unsignedInt 0…595
Timing stop functionlistdeactivated
Warning functionlistdeactivated
Warning timelist15 sec
Load deactivation time [ms]unsignedInt 500…1500500
Activation command during timinglistreset
Multiplicative factor maximum valueunsignedInt 2…52
Timing setting via buslistdeactivated
Flashing start valuelistdeactivated
Activation time [min]unsignedInt 0…590
Activation time [sec]unsignedInt 0…595
Deactivation time [min]unsignedInt 0…590
Deactivation time [sec]unsignedInt 0…595
Block functionlistdeactivated
Block activation valuelist"1" value
Block object start valuelist"0" value
Relay status on active blocklistopen (with NO) / closed (with NC)
Relay status on block deactivationlistfollows last received command
Forced positioning functionlistdeactivated
Relay status on forced positioning endlistfollows last received command
Safety functionlistdeactivated
Control methodlistperiodic transmission absence
Relay status on safetylistopen (with NO) / closed (with NC)
Monitoring time [minutes]unsignedInt 0…5959
Monitoring time [seconds]unsignedInt 0…5959
Logic functionlistdeactivated
Logical operation to executelistOR
Logical input numberunsignedInt 1…41
Logical input operationlistOR
Input 1 value on sendinglist"0" value
Input 2 value on sendinglist"0" value
Input 3 value on sendinglist"0" value
Input 4 value on sendinglist"0" value
NOT operation for input 1listdeactivated
NOT operation for input 2listdeactivated
NOT operation for input 3listdeactivated
NOT operation for input 4listdeactivated
Scenes functionlistdeactivated
Scene number 1listunassigned
Scene 1 storinglistenabled
Start status scene 1 relaylistopen (with NO) / closed (with NC)
Scene number 2listunassigned
Scene 2 storinglistenabled
Start status scene 2 relaylistopen (with NO) / closed (with NC)
Scene number 3listunassigned
Scene 3 storinglistenabled
Start status scene 3 relaylistopen (with NO) / closed (with NC)
Scene number 4listunassigned
Scene 4 storinglistenabled
Start status scene 4 relaylistopen (with NO) / closed (with NC)
Scene number 5listunassigned
Scene 5 storinglistenabled
Start status scene 5 relaylistopen (with NO) / closed (with NC)
Scene number 6listunassigned
Scene 6 storinglistenabled
Start status scene 6 relaylistopen (with NO) / closed (with NC)
Scene number 7listunassigned
Scene 7 storinglistenabled
Start status scene 7 relaylistopen (with NO) / closed (with NC)
Scene number 8listunassigned
Scene 8 storinglistenabled
Start status scene 8 relaylistopen (with NO) / closed (with NC)

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Switch actuator 1 ch. 16A S 1.1 1.1 latest$510607212026-11-2580 KBDownload

About this file

This is the official ETS product database for the GEWISS GW12796 (GW12796), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.