KNX Database

GW16974CT

GEWISS · Order number GW16974CT · Climate control devices › Thermostats

Download .knxprod KNX ICE Thermostat S 1.3 1.3 · 318 KB

Product

ManufacturerGEWISS
Product nameGW16974CT
Order numberGW16974CT
Product textKNX ICE Thermostat - titanium
HardwareTermostato ICE KNX
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2019-02-15
Languagesde-DE, en-US, es-ES, it-IT
Catalog entryM-0019_H-16974xx-0_HP-E30B-13-8393_CI-GW16974CT-0
Fingerprint8393
SHA-25604ac5db4d188b06ef72f5f9f35aa6748d29cfad7ab6b760ca79de22e7a25787e
First seen2026-11-25
Markets59 markets

Application program: KNX ICE Thermostat S 1.3 1.3

Application number$E30B
Version1.3
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters1555
Group objects760
Group objects (760)
NoNameFunctionSizeDPTFlags
0CO EASY1 Byte
1CO EASY1 Bit
2CO EASY1 Byte
3CO EASY1 Bit
4CO EASY2 Bytes9.1 temperature (°C)
5CO EASY2 BytesDPT.9
6CO EASY1 Byte
7CO EASY1 Bit
8CO EASY2 Bytes
9CO EASY2 Bytes
10CO EASY2 BytesDPT.9
11CO EASY1 Bit1.1 switch
12CO EASY1 Bit1.1 switch
13CO EASY1 Bit1.1 switch
14CO EASY1 Bit1.1 switch
15CO EASY1 Bit1.1 switch
16CO EASY1 Bit1.1 switch
17CO EASY1 Bit1.1 switch
18CO EASY1 Bit1.1 switch
19CO EASY1 Bit1.1 switch
20CO EASY1 Bit1.1 switch
21CO EASY1 Bit1.1 switch
22CO EASY1 Bit1.1 switch
23CO EASY1 Bit1.1 switch
24CO EASY1 Bit1.1 switch
25CO EASY1 Bit1.1 switch
26CO EASY1 Bit1.1 switch
27CO EASY1 Bit1.1 switch
28CO EASY1 Bit1.1 switch
29CO EASY1 Byte
30CO EASY2 Bytes9.1 temperature (°C)
31CO EASY1 Bit1.1 switch
32CO EASY1 Bit1.1 switch
33CO EASY1 Byte
34CO EASY2 Bytes9.1 temperature (°C)
35CO EASY1 Bit1.1 switch
36CO EASY1 Bit1.1 switch
37CO EASY1 Byte
38CO EASY2 Bytes9.1 temperature (°C)
39CO EASY1 Bit1.1 switch
40CO EASY1 Bit1.1 switch
41CO EASY1 Byte
42CO EASY2 Bytes9.1 temperature (°C)
43CO EASY1 Bit1.1 switch
44CO EASY1 Bit1.1 switch
45CO EASY1 Byte
46CO EASY2 Bytes9.1 temperature (°C)
47CO EASY1 Bit1.1 switch
48CO EASY1 Bit1.1 switch
49CO EASY1 Bit1.8 up/down
50CO EASY2 Bit2.1 switch control
51CO EASY4 Bit3.7 dimming control
52CO EASY1 Byte
53CO EASY1 Bit1.1 switch
54CO EASY1 Bit1.1 switch
55CO EASY1 Bit1.8 up/down
56CO EASY2 Bit2.1 switch control
57CO EASY4 Bit3.7 dimming control
58CO EASY1 Byte
59Day/Hour inputUpdate day/hour3 Bytes10.1 time of dayCWTU
60Daylight saving time input1= daylight saving/0= standard1 Bit1.1 switchCW
61Day/Hour sendingSend day/hour3 Bytes10.1 time of dayCRT
62Glass cleaningSwitching On/Off1 Bit1.10 start/stopCW
63Enabling slave functionEnable/Disable1 Bit1.3 enableCW
64HVAC mode inputEco/Precom/Comf/Off1 Byte20.102 HVAC modeCW
64Setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
64Setpoint input°K value2 Bytes9.2 temperature difference (K)CW
64Setpoint input°F value2 Bytes9.27 temperature (°F)CW
64Setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
65Setpoint temporary forcing regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
66HVAC off mode inputEnable/Disable1 Bit1.3 enableCW
67HVAC economy mode inputEnable/Disable1 Bit1.3 enableCW
68HVAC precomfort mode inputEnable/Disable1 Bit1.3 enableCW
69HVAC comfort mode inputEnable/Disable1 Bit1.3 enableCW
70Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCW
71Enable dead zoneEnable/Disable1 Bit1.3 enableCW
72Heating anti-freeze setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
72Heating anti-freeze setpoint input°K value2 Bytes9.2 temperature difference (K)CW
72Heating anti-freeze setpoint input°F value2 Bytes9.27 temperature (°F)CW
72Heating anti-freeze setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
73Heating economy setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
73Heating economy setpoint input°K value2 Bytes9.2 temperature difference (K)CW
73Heating economy setpoint input°F value2 Bytes9.27 temperature (°F)CW
73Heating economy setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
74Heating precomfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
74Heating precomfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
74Heating precomfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
74Heating precomfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
75Heating comfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
75Heating comfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
75Heating comfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
75Heating comfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
76Air-cooling high temp. protection setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
76Air-cooling high temp. protection setpoint input°K value2 Bytes9.2 temperature difference (K)CW
76Air-cooling high temp. protection setpoint input°F value2 Bytes9.27 temperature (°F)CW
76Air-cooling high temp. protec. setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
77Air-cooling economy setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
77Air-cooling economy setpoint input°K value2 Bytes9.2 temperature difference (K)CW
77Air-cooling economy setpoint input°F value2 Bytes9.27 temperature (°F)CW
77Air-cooling economy setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
78Air-cooling precomfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
78Air-cooling precomfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
78Air-cooling precomfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
78Air-cooling precomfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
79Air-cooling comfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
79Air-cooling comfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
79Air-cooling comfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
79Air-cooling comfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
80Setpoint regulation range settingValue °C2 Bytes9.1 temperature (°C)CW
81Heating valve switchOn/Off1 Bit1.1 switchCRT
81% command valve heating % Value1 Byte5.1 percentage (0..100%)CRT
81Heating/Air cooling valve switchOn/Off1 Bit1.1 switchCRT
81Heating/air cooling valve % command% Value1 Byte5.1 percentage (0..100%)CRT
82Heating valve status feedbackOn/Off status1 Bit1.1 switchCWTU
82Heating valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
82Heating/air cooling valve status feedbackOn/Off status1 Bit1.1 switchCWTU
82Heating/Air cooling valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
83V1 fan switching heatingOn/Off1 Bit1.1 switchCRT
84V2 fan switching heatingOn/Off1 Bit1.1 switchCRT
85V3 fan switching heatingOn/Off1 Bit1.1 switchCRT
86Heating fan V1 status feedbackOn/Off status1 Bit1.1 switchCWTU
87Heating fan V2 status feedbackOn/Off status1 Bit1.1 switchCWTU
88Heating fan V3 status feedbackOn/Off status1 Bit1.1 switchCWTU
89Heating 2° stage switchingOn/Off1 Bit1.1 switchCRT
89% command 2° stage heating % Value1 Byte5.1 percentage (0..100%)CRT
90Heating 2° stage feedbackOn/Off status1 Bit1.1 switchCWTU
90Heating 2° stage valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
91Air cooling valve % command% Value1 Byte5.1 percentage (0..100%)CRT
91Air cooling valve switchOn/Off1 Bit1.1 switchCRT
92Air cooling valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
92Air cooling valve status feedbackOn/Off status1 Bit1.1 switchCWTU
93V1 fan switching air coolingOn/Off1 Bit1.1 switchCRT
94V2 fan switching air coolingOn/Off1 Bit1.1 switchCRT
95V3 fan switching air coolingOn/Off1 Bit1.1 switchCRT
96Air cooling fan V1 status feedbackOn/Off status1 Bit1.1 switchCWTU
97Air cooling fan V2 status feedbackOn/Off status1 Bit1.1 switchCWTU
98Air cooling fan V3 status feedbackOn/Off status1 Bit1.1 switchCWTU
99% command 2° stage air cooling % Value1 Byte5.1 percentage (0..100%)CRT
99Air cooling 2° stage switchingOn/Off1 Bit1.1 switchCRT
100Air cooling 2° stage valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
100Air cooling 2° stage feedbackOn/Off status1 Bit1.1 switchCWTU
101Fancoil mode inputAutomatic/manual1 Bit1.1 switchCW
102Fan coil mode reportAutomatic/manual1 Bit1.1 switchCRT
103KNX external sensor inputValue °C2 Bytes9.1 temperature (°C)CWTU
103KNX external sensor input°K value2 Bytes9.2 temperature difference (K)CWTU
103KNX external sensor input°F value2 Bytes9.27 temperature (°F)CWTU
103KNX floor sensor inputValue °C2 Bytes9.1 temperature (°C)CWTU
103KNX floor sensor input°K value2 Bytes9.2 temperature difference (K)CWTU
103KNX floor sensor input°F value2 Bytes9.27 temperature (°F)CWTU
104Auxiliary sensor measured temperatureValue °C2 Bytes9.1 temperature (°C)CR
104Auxiliary sensor measured temperature°K value2 Bytes9.2 temperature difference (K)CR
104Auxiliary sensor measured temperature°F value2 Bytes9.27 temperature (°F)CR
104Auxiliary sensor measured temperatureValue °C2 Bytes9.1 temperature (°C)CRT
104Auxiliary sensor measured temperature°K value2 Bytes9.2 temperature difference (K)CRT
104Auxiliary sensor measured temperature°F value2 Bytes9.27 temperature (°F)CRT
105Measured temperatureValue °C2 Bytes9.1 temperature (°C)CR
105Measured temperature°K value2 Bytes9.2 temperature difference (K)CR
105Measured temperature°F value2 Bytes9.27 temperature (°F)CR
105Measured temperatureValue °C2 Bytes9.1 temperature (°C)CRT
105Measured temperature°K value2 Bytes9.2 temperature difference (K)CRT
105Measured temperature°F value2 Bytes9.27 temperature (°F)CRT
106HVAC mode feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCR
106HVAC mode feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
106Functioning setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
106Functioning setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
106Functioning setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
106Functioning setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
106Functioning setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
106Functioning setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
107HVAC off mode feedbackEnable/Disable1 Bit1.3 enableCR
107HVAC off mode feedbackEnable/Disable1 Bit1.3 enableCRT
108HVAC economy mode feedbackEnable/Disable1 Bit1.3 enableCR
108HVAC economy mode feedbackEnable/Disable1 Bit1.3 enableCRT
109HVAC precomfort mode feedbackEnable/Disable1 Bit1.3 enableCR
109HVAC precomfort mode feedbackEnable/Disable1 Bit1.3 enableCRT
110HVAC comfort mode feedbackEnable/Disable1 Bit1.3 enableCR
110HVAC comfort mode feedbackEnable/Disable1 Bit1.3 enableCRT
111Functioning type feedbackHeating/Air cooling1 Bit1.100 heating/coolingCRT
111Functioning type feedbackHeating/Air cooling1 Bit1.100 heating/coolingCR
112Heating anti-freeze setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
112Heating anti-freeze setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
112Heating anti-freeze setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
112Heating anti-freeze setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
112Heating anti-freeze setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
112Heating anti-freeze setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
113Heating economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
113Heating economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
113Heating economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
113Heating economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
113Heating economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
113Heating economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
114Heating precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
114Heating precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
114Heating precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
114Heating precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
114Heating precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
114Heating precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
115Heating comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
115Heating comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
115Heating comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
115Heating comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
115Heating comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
115Heating comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
116Air cond. high temp. protection setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
116Air cond. high temp. protection setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
116Air cond. high temp. protection setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
116Air cond. high temp. protection setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
116Air cond. high temp. protection setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
116Air cond. high temp. protection setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
117Air cooling economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
117Air cooling economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
117Air cooling economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
117Air cooling economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
117Air cooling economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
117Air cooling economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
118Air cooling precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
118Air cooling precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
118Air cooling precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
118Air cooling precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
118Air cooling precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
118Air cooling precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
119Air cooling comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
119Air cooling comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
119Air cooling comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
119Air cooling comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
119Air cooling comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
119Air cooling comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
120Current setpoint reportValue °C2 Bytes9.1 temperature (°C)CR
120Current setpoint report°K value2 Bytes9.2 temperature difference (K)CR
120Current setpoint report°F value2 Bytes9.27 temperature (°F)CR
120Current setpoint reportValue °C2 Bytes9.1 temperature (°C)CRT
120Current setpoint report°K value2 Bytes9.2 temperature difference (K)CRT
120Current setpoint report°F value2 Bytes9.27 temperature (°F)CRT
121Thermostat functioning feedbackSlave/Stand alone1 Bit1.1 switchCR
121Thermostat functioning feedbackSlave/Stand alone1 Bit1.1 switchCRT
122Feedbacks sending triggerSend feedbacks1 Bit1.17 triggerCW
123Thermostat sceneExecute/Store1 Byte18.1 scene controlCW
124Humidity external sensor inputValue [% RH]2 Bytes9.7 humidity (%)CWTU
125Relative humidity measuredValue [% RH]2 Bytes9.7 humidity (%)CRT
125Relative humidity measuredValue [% RH]2 Bytes9.7 humidity (%)CR
126Specific humidityValue [g/kg]4 Bytes14.5 amplitudeCRT
126Specific humidityValue [g/kg]4 Bytes14.5 amplitudeCR
127Relative humidity threshold 1 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
127Relative humidity threshold 1 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
128Relative humidity threshold 1 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
129Relative humidity threshold 1 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
129Relative humidity threshold 1 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
130Relative humidity threshold 1 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
131Relative humidity threshold 1 output A1/0 value1 Bit1.1 switchCRT
131Relative humidity threshold 1 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
131Relative humidity threshold 1 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
131Relative humidity threshold 1 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
131Relative humidity threshold 1 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
131Relative humidity threshold 1 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
131Relative humidity threshold 1 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
131Relative humidity threshold 1 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
131Relative humidity threshold 1 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
131Relative humidity threshold 1 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
131Relative humidity threshold 1 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
132Relative humidity threshold 1 output A statusOn/Off status1 Bit1.1 switchCWTU
132Output A relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
132Output A relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
132Output A relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
132Output A relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
133Relative humidity threshold 1 output B1/0 value1 Bit1.1 switchCRT
133Relative humidity threshold 1 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
133Relative humidity threshold 1 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
133Relative humidity threshold 1 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
133Relative humidity threshold 1 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
133Relative humidity threshold 1 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
133Relative humidity threshold 1 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
133Relative humidity threshold 1 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
133Relative humidity threshold 1 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
133Relative humidity threshold 1 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
133Relative humidity threshold 1 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
134Relative humidity threshold 1 output B statusOn/Off status1 Bit1.1 switchCWTU
134Output B relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
134Output B relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
134Output B relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
134Output B relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
135Relative humidity threshold 1 output C1/0 value1 Bit1.1 switchCRT
135Relative humidity threshold 1 output COn/Off forced positioning2 Bit2.1 switch controlCRT
135Relative humidity threshold 1 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
135Relative humidity threshold 1 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
135Relative humidity threshold 1 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
135Relative humidity threshold 1 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
135Relative humidity threshold 1 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
135Relative humidity threshold 1 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
135Relative humidity threshold 1 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
135Relative humidity threshold 1 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
135Relative humidity threshold 1 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
136Relative humidity threshold 1 output C statusOn/Off status1 Bit1.1 switchCWTU
136Output C relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
136Output C relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
136Output C relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
136Output C relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
137Relative humidity threshold 1 output D1/0 value1 Bit1.1 switchCRT
137Relative humidity threshold 1 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
137Relative humidity threshold 1 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
137Relative humidity threshold 1 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
137Relative humidity threshold 1 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
137Relative humidity threshold 1 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
137Relative humidity threshold 1 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
137Relative humidity threshold 1 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
137Relative humidity threshold 1 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
137Relative humidity threshold 1 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
137Relative humidity threshold 1 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
138Relative humidity threshold 1 output D statusOn/Off status1 Bit1.1 switchCWTU
138Output D relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
138Output D relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
138Output D relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
138Output D relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
139Relative humidity threshold 2 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
139Relative humidity threshold 2 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
140Relative humidity threshold 2 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
141Relative humidity threshold 2 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
141Relative humidity threshold 2 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
142Relative humidity threshold 2 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
143Relative humidity threshold 2 output A1/0 value1 Bit1.1 switchCRT
143Relative humidity threshold 2 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
143Relative humidity threshold 2 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
143Relative humidity threshold 2 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
143Relative humidity threshold 2 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
143Relative humidity threshold 2 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
143Relative humidity threshold 2 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
143Relative humidity threshold 2 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
143Relative humidity threshold 2 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
143Relative humidity threshold 2 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
143Relative humidity threshold 2 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
144Relative humidity threshold 2 output A statusOn/Off status1 Bit1.1 switchCWTU
144Output A relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
144Output A relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
144Output A relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
144Output A relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
145Relative humidity threshold 2 output B1/0 value1 Bit1.1 switchCRT
145Relative humidity threshold 2 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
145Relative humidity threshold 2 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
145Relative humidity threshold 2 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
145Relative humidity threshold 2 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
145Relative humidity threshold 2 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
145Relative humidity threshold 2 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
145Relative humidity threshold 2 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
145Relative humidity threshold 2 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
145Relative humidity threshold 2 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
145Relative humidity threshold 2 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
146Relative humidity threshold 2 output B statusOn/Off status1 Bit1.1 switchCWTU
146Output B relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
146Output B relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
146Output B relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
146Output B relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
147Relative humidity threshold 2 output C1/0 value1 Bit1.1 switchCRT
147Relative humidity threshold 2 output COn/Off forced positioning2 Bit2.1 switch controlCRT
147Relative humidity threshold 2 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
147Relative humidity threshold 2 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
147Relative humidity threshold 2 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
147Relative humidity threshold 2 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
147Relative humidity threshold 2 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
147Relative humidity threshold 2 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
147Relative humidity threshold 2 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
147Relative humidity threshold 2 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
147Relative humidity threshold 2 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
148Relative humidity threshold 2 output C statusOn/Off status1 Bit1.1 switchCWTU
148Output C relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
148Output C relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
148Output C relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
148Output C relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
149Relative humidity threshold 2 output D1/0 value1 Bit1.1 switchCRT
149Relative humidity threshold 2 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
149Relative humidity threshold 2 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
149Relative humidity threshold 2 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
149Relative humidity threshold 2 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
149Relative humidity threshold 2 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
149Relative humidity threshold 2 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
149Relative humidity threshold 2 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
149Relative humidity threshold 2 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
149Relative humidity threshold 2 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
149Relative humidity threshold 2 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
150Relative humidity threshold 2 output D statusOn/Off status1 Bit1.1 switchCWTU
150Output D relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
150Output D relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
150Output D relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
150Output D relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
151Relative humidity threshold 3 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
151Relative humidity threshold 3 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
152Relative humidity threshold 3 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
153Relative humidity threshold 3 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
153Relative humidity threshold 3 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
154Relative humidity threshold 3 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
155Relative humidity threshold 3 output A1/0 value1 Bit1.1 switchCRT
155Relative humidity threshold 3 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
155Relative humidity threshold 3 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
155Relative humidity threshold 3 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
155Relative humidity threshold 3 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
155Relative humidity threshold 3 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
155Relative humidity threshold 3 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
155Relative humidity threshold 3 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
155Relative humidity threshold 3 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
155Relative humidity threshold 3 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
155Relative humidity threshold 3 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
156Relative humidity threshold 3 output A statusOn/Off status1 Bit1.1 switchCWTU
156Output A relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
156Output A relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
156Output A relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
156Output A relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
157Relative humidity threshold 3 output B1/0 value1 Bit1.1 switchCRT
157Relative humidity threshold 3 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
157Relative humidity threshold 3 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
157Relative humidity threshold 3 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
157Relative humidity threshold 3 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
157Relative humidity threshold 3 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
157Relative humidity threshold 3 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
157Relative humidity threshold 3 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
157Relative humidity threshold 3 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
157Relative humidity threshold 3 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
157Relative humidity threshold 3 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
158Relative humidity threshold 3 output B statusOn/Off status1 Bit1.1 switchCWTU
158Output B relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
158Output B relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
158Output B relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
158Output B relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
159Relative humidity threshold 3 output C1/0 value1 Bit1.1 switchCRT
159Relative humidity threshold 3 output COn/Off forced positioning2 Bit2.1 switch controlCRT
159Relative humidity threshold 3 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
159Relative humidity threshold 3 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
159Relative humidity threshold 3 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
159Relative humidity threshold 3 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
159Relative humidity threshold 3 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
159Relative humidity threshold 3 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
159Relative humidity threshold 3 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
159Relative humidity threshold 3 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
159Relative humidity threshold 3 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
160Relative humidity threshold 3 output C statusOn/Off status1 Bit1.1 switchCWTU
160Output C relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
160Output C relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
160Output C relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
160Output C relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
161Relative humidity threshold 3 output D1/0 value1 Bit1.1 switchCRT
161Relative humidity threshold 3 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
161Relative humidity threshold 3 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
161Relative humidity threshold 3 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
161Relative humidity threshold 3 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
161Relative humidity threshold 3 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
161Relative humidity threshold 3 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
161Relative humidity threshold 3 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
161Relative humidity threshold 3 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
161Relative humidity threshold 3 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
161Relative humidity threshold 3 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
162Relative humidity threshold 3 output D statusOn/Off status1 Bit1.1 switchCWTU
162Output D relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
162Output D relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
162Output D relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
162Output D relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
163Relative humidity threshold 4 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
163Relative humidity threshold 4 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
164Relative humidity threshold 4 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
165Relative humidity threshold 4 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
165Relative humidity threshold 4 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
166Relative humidity threshold 4 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
167Relative humidity threshold 4 output A1/0 value1 Bit1.1 switchCRT
167Relative humidity threshold 4 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
167Relative humidity threshold 4 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
167Relative humidity threshold 4 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
167Relative humidity threshold 4 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
167Relative humidity threshold 4 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
167Relative humidity threshold 4 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
167Relative humidity threshold 4 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
167Relative humidity threshold 4 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
167Relative humidity threshold 4 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
167Relative humidity threshold 4 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
168Relative humidity threshold 4 output A statusOn/Off status1 Bit1.1 switchCWTU
168Output A relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
168Output A relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
168Output A relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
168Output A relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
169Relative humidity threshold 4 output B1/0 value1 Bit1.1 switchCRT
169Relative humidity threshold 4 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
169Relative humidity threshold 4 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
169Relative humidity threshold 4 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
169Relative humidity threshold 4 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
169Relative humidity threshold 4 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
169Relative humidity threshold 4 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
169Relative humidity threshold 4 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
169Relative humidity threshold 4 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
169Relative humidity threshold 4 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
169Relative humidity threshold 4 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
170Relative humidity threshold 4 output B statusOn/Off status1 Bit1.1 switchCWTU
170Output B relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
170Output B relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
170Output B relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
170Output B relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
171Relative humidity threshold 4 output C1/0 value1 Bit1.1 switchCRT
171Relative humidity threshold 4 output COn/Off forced positioning2 Bit2.1 switch controlCRT
171Relative humidity threshold 4 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
171Relative humidity threshold 4 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
171Relative humidity threshold 4 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
171Relative humidity threshold 4 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
171Relative humidity threshold 4 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
171Relative humidity threshold 4 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
171Relative humidity threshold 4 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
171Relative humidity threshold 4 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
171Relative humidity threshold 4 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
172Relative humidity threshold 4 output C statusOn/Off status1 Bit1.1 switchCWTU
172Output C relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
172Output C relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
172Output C relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
172Output C relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
173Relative humidity threshold 4 output D1/0 value1 Bit1.1 switchCRT
173Relative humidity threshold 4 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
173Relative humidity threshold 4 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
173Relative humidity threshold 4 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
173Relative humidity threshold 4 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
173Relative humidity threshold 4 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
173Relative humidity threshold 4 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
173Relative humidity threshold 4 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
173Relative humidity threshold 4 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
173Relative humidity threshold 4 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
173Relative humidity threshold 4 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
174Relative humidity threshold 4 output D statusOn/Off status1 Bit1.1 switchCWTU
174Output D relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
174Output D relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
174Output D relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
174Output D relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
175Relative humidity threshold 5 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
175Relative humidity threshold 5 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
176Relative humidity threshold 5 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
177Relative humidity threshold 5 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
177Relative humidity threshold 5 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
178Relative humidity threshold 5 feedbackValue [% RH]2 BytesDPT.9CRT
179Relative humidity threshold 5 output A1/0 value1 Bit1.1 switchCRT
179Relative humidity threshold 5 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
179Relative humidity threshold 5 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
179Relative humidity threshold 5 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
179Relative humidity threshold 5 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
179Relative humidity threshold 5 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
179Relative humidity threshold 5 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
179Relative humidity threshold 5 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
179Relative humidity threshold 5 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
179Relative humidity threshold 5 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
179Relative humidity threshold 5 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
180Relative humidity threshold 5 output A statusOn/Off status1 Bit1.1 switchCWTU
180Output A relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
180Output A relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
180Output A relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
180Output A relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
181Relative humidity threshold 5 output B1/0 value1 Bit1.1 switchCRT
181Relative humidity threshold 5 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
181Relative humidity threshold 5 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
181Relative humidity threshold 5 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
181Relative humidity threshold 5 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
181Relative humidity threshold 5 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
181Relative humidity threshold 5 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
181Relative humidity threshold 5 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
181Relative humidity threshold 5 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
181Relative humidity threshold 5 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
181Relative humidity threshold 5 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
182Relative humidity threshold 5 output B statusOn/Off status1 Bit1.1 switchCWTU
182Output B relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
182Output B relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
182Output B relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
182Output B relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
183Relative humidity threshold 5 output C1/0 value1 Bit1.1 switchCRT
183Relative humidity threshold 5 output COn/Off forced positioning2 Bit2.1 switch controlCRT
183Relative humidity threshold 5 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
183Relative humidity threshold 5 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
183Relative humidity threshold 5 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
183Relative humidity threshold 5 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
183Relative humidity threshold 5 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
183Relative humidity threshold 5 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
183Relative humidity threshold 5 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
183Relative humidity threshold 5 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
183Relative humidity threshold 5 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
184Relative humidity threshold 5 output C statusOn/Off status1 Bit1.1 switchCWTU
184Output C relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
184Output C relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
184Output C relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
184Output C relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
185Relative humidity threshold 5 output D1/0 value1 Bit1.1 switchCRT
185Relative humidity threshold 5 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
185Relative humidity threshold 5 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
185Relative humidity threshold 5 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
185Relative humidity threshold 5 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
185Relative humidity threshold 5 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
185Relative humidity threshold 5 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
185Relative humidity threshold 5 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
185Relative humidity threshold 5 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
185Relative humidity threshold 5 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
185Relative humidity threshold 5 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
186Relative humidity threshold 5 output D statusOn/Off status1 Bit1.1 switchCWTU
186Output D relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
186Output D relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
186Output D relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
186Output D relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
187Season selection input1=Summer / 0=Winter1 Bit1.2 booleanCWTU
187Season selection input1=Winter / 0=Summer1 Bit1.2 booleanCWTU
188Thermal comfort status feedback1=Comfortable/0=Uncomfortable1 Bit1.2 booleanCRT
189IN.1 - BlockSwitching On/Off1 Bit1.3 enableCW
190IN.1 - A object 14 bytes valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
190IN.1 - A object 1 bit value1/0 value1 Bit1.1 switchCRT
190IN.1 - A object 2 bits valueOn/Off forced positioning2 Bit2.1 switch controlCRT
190IN.1 - A object 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
190IN.1 - A object 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
190IN.1 - A object 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
190IN.1 - A object 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
190IN.1 - A object 2 bytes valueUnsigned value2 Bytes7.1 pulsesCRT
190IN.1 - A object 2 bytes valueSigned value2 Bytes8.1 pulses differenceCRT
190IN.1 - A object 4 bytes valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
190IN.1 - A object 4 bytes valueSigned value4 Bytes13.1 counter pulses (signed)CRT
190IN.1 - SwitchOn/Off1 Bit1.1 switchCRT
190IN.1 - Shutter movementUp/Down1 Bit1.8 up/downCRT
190IN.1 - SceneExecute/Store1 Byte18.1 scene controlCRT
190IN.1 - Window status feedbackOpen/Closed1 Bit1.19 window/doorCRT
190IN.1 - Window status feedbackOpen/Closed1 Bit1.19 window/doorCR
190IN.1 - A object 3 byte valueRGB color3 Bytes232.600 RGB value 3x(0..255)CRT
191IN.1 - Brightness dimmingIncrease/Decrease4 Bit3.7 dimming controlCRT
191IN.1 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
191IN.1 - Scene storing triggerStore1 Bit1.17 triggerCW
191IN.1 - B object 14 bytes valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
191IN.1 - B object 1 bit value1/0 value1 Bit1.1 switchCRT
191IN.1 - B object 2 bits valueOn/Off forced positioning2 Bit2.1 switch controlCRT
191IN.1 - B object 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
191IN.1 - B object 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
191IN.1 - B object 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
191IN.1 - B object 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
191IN.1 - B object 2 bytes valueUnsigned value2 Bytes7.1 pulsesCRT
191IN.1 - B object 2 bytes valueSigned value2 Bytes8.1 pulses differenceCRT
191IN.1 - B object 4 bytes valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
191IN.1 - B object 4 bytes valueSigned value4 Bytes13.1 counter pulses (signed)CRT
191IN.1 - B object 3 byte valueRGB color3 Bytes232.600 RGB value 3x(0..255)CRT
192IN.1 - C object 14 bytes valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
192IN.1 - C object 1 bit value1/0 value1 Bit1.1 switchCRT
192IN.1 - C object 2 bits valueOn/Off forced positioning2 Bit2.1 switch controlCRT
192IN.1 - C object 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
192IN.1 - C object 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
192IN.1 - C object 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
192IN.1 - C object 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
192IN.1 - C object 2 bytes valueUnsigned value2 Bytes7.1 pulsesCRT
192IN.1 - C object 2 bytes valueSigned value2 Bytes8.1 pulses differenceCRT
192IN.1 - C object 4 bytes valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
192IN.1 - C object 4 bytes valueSigned value4 Bytes13.1 counter pulses (signed)CRT
192IN.1 - C object 3 byte valueRGB color3 Bytes232.600 RGB value 3x(0..255)CRT
193IN.1 - D object 14 bytes valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
193IN.1 - D object 1 bit value1/0 value1 Bit1.1 switchCRT
193IN.1 - D object 2 bits valueOn/Off forced positioning2 Bit2.1 switch controlCRT
193IN.1 - D object 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
193IN.1 - D object 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
193IN.1 - D object 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
193IN.1 - D object 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
193IN.1 - D object 2 bytes valueUnsigned value2 Bytes7.1 pulsesCRT
193IN.1 - D object 2 bytes valueSigned value2 Bytes8.1 pulses differenceCRT
193IN.1 - D object 4 bytes valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
193IN.1 - D object 4 bytes valueSigned value4 Bytes13.1 counter pulses (signed)CRT
193IN.1 - D object 3 byte valueRGB color3 Bytes232.600 RGB value 3x(0..255)CRT
194IN.1 - Oggetto 54 BytesCRT
195IN.1 - Oggetto 64 BytesCRT
196IN.1 - Oggetto 74 BytesCRT
197IN.1 - Oggetto 84 BytesCRT
198IN.1 - Oggetto 94 BytesCRT
199IN.1 - Oggetto 104 BytesCRT
200IN.1 - Oggetto 114 BytesCRT
201IN.1 - Oggetto 124 BytesCRT
202IN.1 - Oggetto 134 BytesCRT
203IN.1 - Oggetto 144 BytesCRT
204IN.1 - Oggetto 154 BytesCRT
205IN.1 - Oggetto 164 BytesCRT
206IN.1 - Oggetto 174 BytesCRT
207IN.1 - Oggetto 184 BytesCRT
208IN.1 - Oggetto 194 BytesCRT
209IN.1 - Oggetto 204 BytesCRT
210IN.1 - Dimmer status feedbackOn/Off status1 Bit1.1 switchCWTU
210IN.1 - A object status feedbackOn/Off status1 Bit1.1 switchCWTU
210IN.1 - Movement feedbackIncrease/Decrease1 Bit1.8 up/downCW
211IN.1 - B object status feedbackOn/Off status1 Bit1.1 switchCWTU
212IN.1 - C object status feedbackOn/Off status1 Bit1.1 switchCWTU
213IN.1 - D object status feedbackOn/Off status1 Bit1.1 switchCWTU
214IN.2 - BlockSwitching On/Off1 Bit1.3 enableCW
215IN.2 - A object 14 bytes valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
215IN.2 - A object 1 bit value1/0 value1 Bit1.1 switchCRT
215IN.2 - A object 2 bits valueOn/Off forced positioning2 Bit2.1 switch controlCRT
215IN.2 - A object 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
215IN.2 - A object 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
215IN.2 - A object 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
215IN.2 - A object 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
215IN.2 - A object 2 bytes valueUnsigned value2 Bytes7.1 pulsesCRT
215IN.2 - A object 2 bytes valueSigned value2 Bytes8.1 pulses differenceCRT
215IN.2 - A object 4 bytes valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
215IN.2 - A object 4 bytes valueSigned value4 Bytes13.1 counter pulses (signed)CRT
215IN.2 - SwitchOn/Off1 Bit1.1 switchCRT
215IN.2 - Shutter movementUp/Down1 Bit1.8 up/downCRT
215IN.2 - SceneExecute/Store1 Byte18.1 scene controlCRT
215IN.2 - A object 3 byte valueRGB color3 Bytes232.600 RGB value 3x(0..255)CRT
216IN.2 - Brightness dimmingIncrease/Decrease4 Bit3.7 dimming controlCRT
216IN.2 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
216IN.2 - Scene storing triggerStore1 Bit1.17 triggerCW
216IN.2 - B object 14 bytes valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
216IN.2 - B object 1 bit value1/0 value1 Bit1.1 switchCRT
216IN.2 - B object 2 bits valueOn/Off forced positioning2 Bit2.1 switch controlCRT
216IN.2 - B object 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
216IN.2 - B object 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
216IN.2 - B object 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
216IN.2 - B object 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
216IN.2 - B object 2 bytes valueUnsigned value2 Bytes7.1 pulsesCRT
216IN.2 - B object 2 bytes valueSigned value2 Bytes8.1 pulses differenceCRT
216IN.2 - B object 4 bytes valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
216IN.2 - B object 4 bytes valueSigned value4 Bytes13.1 counter pulses (signed)CRT
216IN.2 - B object 3 byte valueRGB color3 Bytes232.600 RGB value 3x(0..255)CRT
217IN.2 - C object 14 bytes valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
217IN.2 - C object 1 bit value1/0 value1 Bit1.1 switchCRT
217IN.2 - C object 2 bits valueOn/Off forced positioning2 Bit2.1 switch controlCRT
217IN.2 - C object 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
217IN.2 - C object 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
217IN.2 - C object 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
217IN.2 - C object 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
217IN.2 - C object 2 bytes valueUnsigned value2 Bytes7.1 pulsesCRT
217IN.2 - C object 2 bytes valueSigned value2 Bytes8.1 pulses differenceCRT
217IN.2 - C object 4 bytes valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
217IN.2 - C object 4 bytes valueSigned value4 Bytes13.1 counter pulses (signed)CRT
217IN.2 - C object 3 byte valueRGB color3 Bytes232.600 RGB value 3x(0..255)CRT
218IN.2 - D object 14 bytes valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
218IN.2 - D object 1 bit value1/0 value1 Bit1.1 switchCRT
218IN.2 - D object 2 bits valueOn/Off forced positioning2 Bit2.1 switch controlCRT
218IN.2 - D object 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
218IN.2 - D object 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
218IN.2 - D object 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
218IN.2 - D object 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
218IN.2 - D object 2 bytes valueUnsigned value2 Bytes7.1 pulsesCRT
218IN.2 - D object 2 bytes valueSigned value2 Bytes8.1 pulses differenceCRT
218IN.2 - D object 4 bytes valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
218IN.2 - D object 4 bytes valueSigned value4 Bytes13.1 counter pulses (signed)CRT
218IN.2 - D object 3 byte valueRGB color3 Bytes232.600 RGB value 3x(0..255)CRT
219IN.2 - Oggetto 54 BytesCRT
220IN.2 - Oggetto 64 BytesCRT
221IN.2 - Oggetto 74 BytesCRT
222IN.2 - Oggetto 84 BytesCRT
223IN.2 - Oggetto 94 BytesCRT
224IN.2 - Oggetto 104 BytesCRT
225IN.2 - Oggetto 114 BytesCRT
226IN.2 - Oggetto 124 BytesCRT
227IN.2 - Oggetto 134 BytesCRT
228IN.2 - Oggetto 144 BytesCRT
229IN.2 - Oggetto 154 BytesCRT
230IN.2 - Oggetto 164 BytesCRT
231IN.2 - Oggetto 174 BytesCRT
232IN.2 - Oggetto 184 BytesCRT
233IN.2 - Oggetto 194 BytesCRT
234IN.2 - Oggetto 204 BytesCRT
235IN.2 - Dimmer status feedbackOn/Off status1 Bit1.1 switchCWTU
235IN.2 - A object status feedbackOn/Off status1 Bit1.1 switchCWTU
235IN.2 - Movement feedbackIncrease/Decrease1 Bit1.8 up/downCW
236IN.2 - B object status feedbackOn/Off status1 Bit1.1 switchCWTU
237IN.2 - C object status feedbackOn/Off status1 Bit1.1 switchCWTU
238IN.2 - D object status feedbackOn/Off status1 Bit1.1 switchCWTU
239Logic input 1Logic function input1 Bit1.2 booleanCWTU
240Logic input 2Logic function input1 Bit1.2 booleanCWTU
241Logic input 3Logic function input1 Bit1.2 booleanCWTU
242Logic input 4Logic function input1 Bit1.2 booleanCWTU
243Logic input 5Logic function input1 Bit1.2 booleanCWTU
244Logic input 6Logic function input1 Bit1.2 booleanCWTU
245Logic input 7Logic function input1 Bit1.2 booleanCWTU
246Logic input 8Logic function input1 Bit1.2 booleanCWTU
247Logic operation outputLogic1 Bit1.2 booleanCRT
Parameters (259)
ParameterTypeDefault
Parameters local modificationlistbasic parameters only
Day and Hour modification via buslistdisable
Thermostat functioningliststand alone
Remote parameters settinglistdisable
- Commands format for HVAC mode settinglist1 byte
- Set functioning typelistdisable
- HVAC mode setpoint modification via buslistdisable
Control logic Heating/Air coolinglistdifferent (4 pipe)
--- Reception 1 bit mode con priority > actuallistkeep lower priority objects value
--- Reception 1 bit mode con priority < actuallistupdate object value
Comfort setpoint (tenths of °C)signedInt 50…400200
Precomfort setpoint (tenths of °C)signedInt 50…400180
Economy setpoint (tenths of °C)signedInt 50…400160
Antifreeze setpoint (tenths of °C)signedInt 20…7050
High temperature protection setpoint (tenths of °C)signedInt 300…400350
Economy setpoint (tenths of °C)signedInt 50…400280
Precomfort setpoint (tenths of °C)signedInt 50…400260
Comfort setpoint (tenths of °C)signedInt 50…400240
Temperature forcing behaviour at new setpoint receivinglistcancel temperature forcing
modify contemporary the setpoint of the other functioning typelistno
modify all the setpoints of the same functioning typelistno
Internal sensor correction factor (tenths of °C)signedInt -20…200
KNX external sensorlistdisabled
- KNX ext. sensor incidence in measured temp. calculationlist10%
- KNX external sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
- KNX floor sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
Measured temperaturelistdo not send
- Measure unitlistCelsius degrees (°C)
- Minimum variation for sending value [± 0.1 °C]unsignedInt 1…105
- Temperature sending period [minutes]unsignedInt 1…2555
HVAC mode feedbacklistdisabled
- 1 bit HVAC modeliston demand only
- 1 byte HVAC modeliston demand only
Functioning type feedbacklistdisabled
Current setpoint reportlistdisabled
Thermostat functioning feedbacklistdisabled
HVAC mode setpoint feedbacklistdisabled
Scenes functionlistdisable
Scene number 1listunassigned
Scene number 2listunassigned
Scene number 3listunassigned
Scene number 4listunassigned
Scene number 5listunassigned
Scene number 6listunassigned
Scene number 7listunassigned
Scene number 8listunassigned
Parameters to memorize while storinglistHVAC mode only
Temperature measure unitlistCelsius degrees (°C)
Matched functionlistnone
Sending object formatlist1 bit
- Sending on opening/long operation detectionlistno effect
- Sending on closing/short operation detectionlist1
- Sending on closing/short operation detectionlistactivate on (down) forcing
- Sending on closing/short operation detectionlistcomfort
- Sending on closing/short operation detectionlistvalue sending
-- Value (0% .. 100%)unsignedInt 0…1000
-- Value (0 .. 255)unsignedInt 0…2550
-- Value (-128 .. +127)signedInt -128…1270
-- Value (0 .. 65535)unsignedInt 0…655350
-- Value (-32768 .. +32767)signedInt -32768…327670
-- Value (0 .. 4294967295)unsignedInt 0…42949672950
-- Value (-2147483648 .. +2147483647)signedInt -2147483648…21474836470
-- Value (characters ISO 8859-1)text
Scene number (0 .. 63)unsignedInt 0…630
Scene storing by long operationlistenabled
- Brightness dimming commands with dimmer onlistbrightness increase and decrease
Increase/decrease steplist12.5%
Cyclical sending period [x 0.1s]unsignedInt 3…505
-- Status feedback objectlistdisabled
Automatic change Daylight Saving Time/Standard Timelistdisable
- Daylight saving time input object value at downloadliststandard time
- Measure unit KNX external sensorlistCelsius degrees (°C)
- KNX floor sensor measure unitlistCelsius degrees (°C)
- Threshold temperature temperature alarm (tenth of °C)unsignedInt 150…1000500
- Behaviour at KNX external sensor signal absencelistuse last value received
- Behaviour at KNX floor sensor signal absencelistactivate temperature alarm
- Auxiliary ext. sensor incidence in measured temp. calculationlist10%
Auxiliary external sensorlistexternal sensor
- Behaviour at auxiliary external sensor signal absencelistuse last value received
- Behaviour at auxiliary floor sensor signal absencelistactivate temperature alarm
- Correction factor auxiliary sensor (tenths of °C)signedInt -20…200
Auxiliary sensor measured temperaturelistdo not send
- Temperature measured by auxiliary floor sensorlistdo not send
-- Auxiliary sensor temperature sending period [minutes]unsignedInt 1…2555
-- Auxiliary sensor temperature min. variation for sending value [± 0.1 °C]unsignedInt 1…105
-- Measure unit auxiliary sensorlistCelsius degrees (°C)
- Temperature alarm hysteresis (tenth of °C)unsignedInt 10…10030
Window statuslistclosed if contact is open
Send window contact status feedbacklistdisabled
Functioning type settinglistby local command or from bus
Heating/Air cooling control algorithmlisttwo points ON-OFF
Heating/air cooling valve status feedbacklistenable
Fancoil valve managementlisttwo points ON-OFF
- Commands repetition period with disabled feedbacklist5 minutes
-- Commands repetition period with disabled feedbacklist5 minutes
- Heating/air cooling valve status feedbacklistenable
Regulation differential (tenth of °C)unsignedInt 1…202
- Proportional bandlist2.0 °C
- Integration timelist60 minutes
- Cycle timelist30 minutes
- Min. % variation for continuous command sendinglist5%
- Regulation differential valve (tenth of °C)unsignedInt 1…202
Fancoil speed numberlist3
- Regulation differential speed 1 (tenth of °C)unsignedInt 0…202
- Regulation differential speed 2 (tenth of °C)unsignedInt 1…202
- Regulation differential speed 3 (tenth of °C)unsignedInt 1…202
- Speed 1 inertia time (seconds)unsignedInt 0…100
- Speed 2 inertia time (seconds)unsignedInt 0…100
- Speed 3 inertia time (seconds)unsignedInt 0…100
Heating valve status feedbacklistenable
Fancoil speed status feedbacklistenable
- Command repetition time fancoil speedlist5 minutes
Select heating systemlistfloor heating
- Heating valve status feedbacklistenable
- Operation limit 2° stage (tenths of °C)unsignedInt 10…10010
- Regulation differential 2° stage (tenth of °C)unsignedInt 1…202
Heating 2° stage feedbacklistenable
- Command repetition time 2° stage without feedbacklist5 minutes
Heating 2° stagelistdisabled
Heating control algorithmlisttwo points ON-OFF
Air cooling control algorithmlisttwo points ON-OFF
Air cooling valve status feedbacklistenable
- Air cooling valve status feedbacklistenable
Select air cooling systemlistceiling cooling
air cooling 2° stagelistdisabled
Air cooling 2° stage feedbacklistenable
Fancoil speed modification via buslistdisable
Fancoil mode (automatic/manual) feedbacklistdisable
Dimmer status feedback objectlistdisable
Stand alone control typelistHVAC mode
Master/Slave control typelistHVAC mode
Allows local switching offlistdisable
- Reactivate device bylistlocal control only
Antifreeze setpoint after manual switching off (tenths of °C)signedInt 20…7050
Setpoint variation range for manual forcing via buslist± 3.0
Setpoint variation range input for manual forcing via buslistdisable
Functioning setpoint feedbacklistdisabled
Parameters to memorize while storinglistsetpoint only
Functioning setpoint (tenths of °C)signedInt 50…400200
Functioning setpoint (tenths of °C)signedInt 50…400240
Feedbacks sending trigger objectlistdisable
- Temporary setpoint forcing via buslistdisable
-- Setpoint temporary forcing regulation step [0.1°C]unsignedInt 1…205
Input contacts functionlisttwo auxiliary inputs independent
Change the functioning setpoint via bus throughlistabsolute value setting (°C)
- Setpoint regulation step [0.1°C]unsignedInt 1…205
KNX external sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
Behaviour at KNX external sensor signal absencelistuse last value received
Relative humidity measuredlistdo not send
- Minimum variation for sending value [% RH]list± 5 %
- Relative humidity value repetition time [minutes]unsignedInt 1…2555
Specific humiditylistdo not send
- Minimum variation for sending valuelist± 5 g/Kg
- Specific relative humidity value repetition time [minutes]unsignedInt 1…2555
Relative humidity threshold 1listdisable
Threshold logic functioning:listhumidification
Limit threshold starting value [% RH]unsignedInt 0…10050
Limit threshold hysteresis [% RH]unsignedInt 1…205
Change the threshold value via bus throughlistabsolute value
- Threshold regulation step via bus [%]unsignedInt 1…205
Enable/disable the humidity threshold (via bus and device menu)listno
- Threshold activation valuelistvalue "1"
- Threshold activation status after bus voltage recoverylistas before voltage drop
C1 = Condition 1listRelative humidity <= Limit threshold - hysteresis
C2 = Condition 2listRelative humidity >= Limit threshold
C1 = Condition 1listRelative humidity >= Limit threshold + hysteresis
C2 = Condition 2listRelative humidity <= Limit threshold
Output formatlist1 bit
- Relative humidity threshold output status feedbacklistenable
- Output commands cyclical repetitionlistdisable
-- Command repetition timelist5 minutes
- On the occurrence of Condition 1listsends 1
- On the occurrence of Condition 2listno effect
- On the occurrence of Condition 1listsends active forcing on(down)
- On the occurrence of Condition 1listsends comfort
- On the occurrence of Condition 1listvalue sending
- On the occurrence of Condition 1listsends current setpoint ± offset
-- Offset [0.1°C] (-300 .. 300)signedInt -300…30010
-- Offset (-3 .. 3)signedInt -3…31
Enable thermal comfort status feedbacklistenable
The season summer/winterlistfollows active functioning type
- Logical value associated with the seasonslist1 = summer / 0 = winter
- Season active after an ETS downloadlistsummer
Maximum temperature [0.1 °C]signedInt 200…400260
Minimum temperature [0.1 °C]signedInt 100…300240
Maximum relative humidity [% RH]unsignedInt 50…9560
Minimum relative humidity [% RH]unsignedInt 10…4540
Maximum specific humidity [% RH]unsignedInt 50…220115
Maximum temperature [0.1 °C]signedInt 200…400220
Minimum temperature [0.1 °C]signedInt 100…300180
Regulation differential valve (tenth of °C)unsignedInt 1…202
- Type of NTC sensor connectedlistfloating sensor (GW10800)
Object B --------------------------------------listdisable
Object C --------------------------------------listdisable
Object D --------------------------------------listdisable
Glass cleaning functionlistenable
- Light signalling for function activation/deactivationlistenable
- Sound signalling for function activation/deactivationlistenable
- Inhibition time [s]unsignedInt 10…24030
-- Priority between objects for HVAC mode remote settinglistenable
Logic input 1listenabled
- NOT operation for logic input 1listdisable
Logic input 2listenabled
- NOT operation for logic input 2listdisable
Logic input 3listdisabled
- NOT operation for logic input 3listdisable
Logic input 4listdisabled
- NOT operation for logic input 4listdisable
Logic input 5listdisabled
- NOT operation for logic input 5listdisable
Logic input 6listdisabled
- NOT operation for logic input 6listdisable
Logic input 7listdisabled
- NOT operation for logic input 7listdisable
Logic input 8listdisabled
- NOT operation for logic input 8listdisable
Operation between logic inputslistAND
The logic operation is computedlistwhenever an input value is received
- Calculation periodunsignedInt 1…2551
Logic functionlistdisable
Generate the result of the logic operationlistwhenever the logic is evaluated
If the result of the logic operation is TRUElistsends "1"
If the result of the logic operation is FALSElistsends "0"
- Backlight brightness intensity percentage valuelist80%
Sound effect for "Touch" eventslistenable
Light signalling for "Touch" eventslistenabled
- Block function on bus voltage recoverylistas before voltage drop
- Block activation valuelistvalue "1"
blocklistdisabled
Debounce time [ms]unsignedInt 10…255100
Long operation minimum time [x 0.1s]unsignedInt 3…1505
Regulation directionlistincrease
Movement directionlistup
Functioning type recognizedlistedges (opening/closing)
Sequence cyclic sending period if open contact/long operation [s]unsignedInt 1…6553515
Sequence cyclic sending period if close contact/short operation [s]unsignedInt 1…6553515
Channel behaviour at bus voltage recoverylistignore contact status and cyclical sending
Cyclic sending object behaviourliston demand
Object sending delay [s]unsignedInt 0…2550
-- BLUE component value (0 .. 255)unsignedInt 0…2550
-- GREEN component value (0 .. 255)unsignedInt 0…2550
-- RED component value (0 .. 255)unsignedInt 0…2550
-- Colorlistwhite
Programming modelistETS mode
Day and hour sending via buslistdisabled
- Day/hour sending periodlist1 week
Relative humidity threshold 2listdisable
Relative humidity threshold 3listdisable
Relative humidity threshold 4listdisable
Relative humidity threshold 5listdisable
- Valvelistfloor heating
-- Proportional bandlist2.0 °C
-- Integration timelist60 minutes
-- Min. % variation for continuous command sendinglist5%
- Valvelistceiling cooling
- Operation limit fancoil (tenths of °C)unsignedInt 1…202
Operation limit fancoil (tenths of °C)unsignedInt 1…202
Valvelistfloor heating
Valvelistceiling cooling

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX ICE Thermostat S 1.3 1.3 latest$E30B83932026-11-25318 KBDownload

About this file

This is the official ETS product database for the GEWISS GW16974CT (GW16974CT), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.