| 0 | Setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 0 | Setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 0 | Setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 0 | HVAC mode input | Eco/Precom/Comf/Off | 1 Byte | 20.102 HVAC mode | CW |
| 1 | HVAC off mode input | Enable/Disable | 1 Bit | 1.3 enable | CW |
| 1 | Temporary setpoint forcing input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 1 | Temporary setpoint forcing input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 1 | Temporary setpoint forcing input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 2 | HVAC economy mode input | Enable/Disable | 1 Bit | 1.3 enable | CW |
| 3 | HVAC precomfort mode input | Enable/Disable | 1 Bit | 1.3 enable | CW |
| 4 | HVAC comfort mode input | Enable/Disable | 1 Bit | 1.3 enable | CW |
| 5 | Functioning type input | Heating/Air cooling | 1 Bit | 1.100 heating/cooling | CW |
| 6 | Enable dead zone | Enable/Disable | 1 Bit | 1.3 enable | CW |
| 7 | Heating anti-freeze setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 7 | Heating anti-freeze setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 7 | Heating anti-freeze setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 8 | Heating economy setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 8 | Heating economy setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 8 | Heating economy setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 9 | Heating precomfort setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 9 | Heating precomfort setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 9 | Heating precomfort setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 10 | Heating comfort setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 10 | Heating comfort setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 10 | Heating comfort setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 11 | Air-cooling high temp. protection setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 11 | Air-cooling high temp. protection setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 11 | Air-cooling high temp. protection setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 12 | Air-cooling economy setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 12 | Air-cooling economy setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 12 | Air-cooling economy setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 13 | Air-cooling precomfort setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 13 | Air-cooling precomfort setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 13 | Air-cooling precomfort setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 14 | Air-cooling comfort setpoint input | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 14 | Air-cooling comfort setpoint input | °K value | 2 Bytes | 9.2 temperature difference (K) | CW |
| 14 | Air-cooling comfort setpoint input | °F value | 2 Bytes | 9.27 temperature (°F) | CW |
| 15 | Heating valve switch | On/Off | 1 Bit | 1.1 switch | CRT |
| 15 | % command valve heating | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 15 | Heating/Air cooling valve switch | On/Off | 1 Bit | 1.1 switch | CRT |
| 15 | Heating/air cooling valve % command | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | Heating valve status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 16 | Heating valve % feedback | % Value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 16 | Heating/air cooling valve status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 16 | Heating/Air cooling valve % feedback | % Value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 17 | V1 fan switching heating | On/Off | 1 Bit | 1.1 switch | CRT |
| 17 | % command fancoil speed heating | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | V2 fan switching heating | On/Off | 1 Bit | 1.1 switch | CRT |
| 19 | V3 fan switching heating | On/Off | 1 Bit | 1.1 switch | CRT |
| 20 | Heating fan V1 status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 20 | Heating fancoil speed % feedback | % Value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 21 | Heating fan V2 status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 22 | Heating fan V3 status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 23 | Heating 2° stage switching | On/Off | 1 Bit | 1.1 switch | CRT |
| 23 | % command 2° stage heating | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 24 | Heating 2° stage feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 24 | Heating 2° stage valve % feedback | % Value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 25 | Air cooling valve % command | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 25 | Air cooling valve switch | On/Off | 1 Bit | 1.1 switch | CRT |
| 26 | Air cooling valve % feedback | % Value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 26 | Air cooling valve status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 27 | % command fancoil speed air cooling | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | V1 fan switching air cooling | On/Off | 1 Bit | 1.1 switch | CRT |
| 28 | V2 fan switching air cooling | On/Off | 1 Bit | 1.1 switch | CRT |
| 29 | V3 fan switching air cooling | On/Off | 1 Bit | 1.1 switch | CRT |
| 30 | Air cooling fancoil speed % feedback | % Value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 30 | Air cooling fan V1 status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 31 | Air cooling fan V2 status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 32 | Air cooling fan V3 status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 33 | % command 2° stage air cooling | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 33 | Air cooling 2° stage switching | On/Off | 1 Bit | 1.1 switch | CRT |
| 34 | Air cooling 2° stage valve % feedback | % Value | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 34 | Air cooling 2° stage feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 35 | Fancoil mode input | Automatic/manual | 1 Bit | 1.1 switch | CW |
| 36 | Fan coil mode report | Automatic/manual | 1 Bit | 1.1 switch | CRT |
| 37 | KNX external sensor input | Value °C | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 37 | KNX external sensor input | °K value | 2 Bytes | 9.2 temperature difference (K) | CWTU |
| 37 | KNX external sensor input | °F value | 2 Bytes | 9.27 temperature (°F) | CWTU |
| 37 | KNX floor sensor input | Value °C | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 37 | KNX floor sensor input | °K value | 2 Bytes | 9.2 temperature difference (K) | CWTU |
| 37 | KNX floor sensor input | °F value | 2 Bytes | 9.27 temperature (°F) | CWTU |
| 38 | Auxiliary sensor measured temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 38 | Auxiliary sensor measured temperature | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 38 | Auxiliary sensor measured temperature | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 38 | Auxiliary sensor measured temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 38 | Auxiliary sensor measured temperature | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 38 | Auxiliary sensor measured temperature | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 39 | Measured temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 39 | Measured temperature | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 39 | Measured temperature | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 39 | Measured temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 39 | Measured temperature | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 39 | Measured temperature | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 40 | Functioning setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 40 | Functioning setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 40 | Functioning setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 40 | Functioning setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 40 | Functioning setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 40 | Functioning setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 40 | HVAC mode feedback | Eco/Precom/Comf/Off | 1 Byte | 20.102 HVAC mode | CR |
| 40 | HVAC mode feedback | Eco/Precom/Comf/Off | 1 Byte | 20.102 HVAC mode | CRT |
| 41 | HVAC off mode feedback | Enable/Disable | 1 Bit | 1.3 enable | CR |
| 41 | HVAC off mode feedback | Enable/Disable | 1 Bit | 1.3 enable | CRT |
| 42 | HVAC economy mode feedback | Enable/Disable | 1 Bit | 1.3 enable | CR |
| 42 | HVAC economy mode feedback | Enable/Disable | 1 Bit | 1.3 enable | CRT |
| 43 | HVAC precomfort mode feedback | Enable/Disable | 1 Bit | 1.3 enable | CR |
| 43 | HVAC precomfort mode feedback | Enable/Disable | 1 Bit | 1.3 enable | CRT |
| 44 | HVAC comfort mode feedback | Enable/Disable | 1 Bit | 1.3 enable | CR |
| 44 | HVAC comfort mode feedback | Enable/Disable | 1 Bit | 1.3 enable | CRT |
| 45 | Functioning type feedback | Heating/Air cooling | 1 Bit | 1.100 heating/cooling | CRT |
| 45 | Functioning type feedback | Heating/Air cooling | 1 Bit | 1.100 heating/cooling | CR |
| 46 | Heating anti-freeze setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 46 | Heating anti-freeze setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 46 | Heating anti-freeze setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 46 | Heating anti-freeze setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 46 | Heating anti-freeze setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 46 | Heating anti-freeze setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 47 | Heating economy setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 47 | Heating economy setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 47 | Heating economy setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 47 | Heating economy setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 47 | Heating economy setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 47 | Heating economy setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 48 | Heating precomfort setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 48 | Heating precomfort setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 48 | Heating precomfort setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 48 | Heating precomfort setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 48 | Heating precomfort setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 48 | Heating precomfort setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 49 | Heating comfort setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 49 | Heating comfort setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 49 | Heating comfort setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 49 | Heating comfort setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 49 | Heating comfort setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 49 | Heating comfort setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 50 | Air cond. high temp. protection setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 50 | Air cond. high temp. protection setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 50 | Air cond. high temp. protection setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 50 | Air cond. high temp. protection setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 50 | Air cond. high temp. protection setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 50 | Air cond. high temp. protection setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 51 | Air cooling economy setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 51 | Air cooling economy setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 51 | Air cooling economy setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 51 | Air cooling economy setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 51 | Air cooling economy setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 51 | Air cooling economy setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 52 | Air cooling precomfort setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 52 | Air cooling precomfort setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 52 | Air cooling precomfort setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 52 | Air cooling precomfort setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 52 | Air cooling precomfort setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 52 | Air cooling precomfort setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 53 | Air cooling comfort setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 53 | Air cooling comfort setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 53 | Air cooling comfort setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 53 | Air cooling comfort setpoint feedback | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 53 | Air cooling comfort setpoint feedback | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 53 | Air cooling comfort setpoint feedback | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 54 | Current setpoint report | °K value | 2 Bytes | 9.2 temperature difference (K) | CR |
| 54 | Current setpoint report | Value °C | 2 Bytes | 9.1 temperature (°C) | CR |
| 54 | Current setpoint report | °F value | 2 Bytes | 9.27 temperature (°F) | CR |
| 54 | Current setpoint report | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 54 | Current setpoint report | °K value | 2 Bytes | 9.2 temperature difference (K) | CRT |
| 54 | Current setpoint report | °F value | 2 Bytes | 9.27 temperature (°F) | CRT |
| 55 | Feedbacks sending trigger | Send feedbacks | 1 Bit | 1.17 trigger | CW |
| 56 | KNX sensor scene | Execute/Store | 1 Byte | 18.1 scene control | CW |
| 57 | Input aux 1 - Dimmer status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 57 | Input aux 1 - Status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 57 | Input aux 1 - Movement feedback | Increase/Decrease | 1 Bit | 1.8 up/down | CW |
| 58 | Input aux 1 - 14 byte value | Characters ISO 8859-1 | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRT |
| 58 | Input aux 1 - 1 bit value | 1/0 value | 1 Bit | 1.1 switch | CRT |
| 58 | Input aux 1 - 2 bit value | On/Off forced positioning | 2 Bit | 2.1 switch control | CRT |
| 58 | Input aux 1 - 1 byte value | Unsigned value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 58 | Input aux 1 - 1 byte value | Signed value | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 58 | Input aux 1 - 1 byte value | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 58 | Input aux 1 - 1 byte value | HVAC mode | 1 Byte | 20.102 HVAC mode | CRT |
| 58 | Input aux 1 - 2 byte value | Unsigned value | 2 Bytes | 7.1 pulses | CRT |
| 58 | Input aux 1 - 2 byte value | Signed value | 2 Bytes | 8.1 pulses difference | CRT |
| 58 | Input aux 1 - 4 byte value | Unsigned value | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 58 | Input aux 1 - 4 byte value | Signed value | 4 Bytes | 13.1 counter pulses (signed) | CRT |
| 58 | Input aux 1 - Switching | On/Off | 1 Bit | 1.1 switch | CRT |
| 58 | Input aux 1 - Shutter movement | Up/Down | 1 Bit | 1.8 up/down | CRT |
| 58 | Input aux 1 - Scene | Execute/Store | 1 Byte | 18.1 scene control | CRT |
| 58 | Input aux 1 - Window status feedback | Open/Closed | 1 Bit | 1.2 boolean | CR |
| 58 | Input aux 1 - Window status feedback | Open/Closed | 1 Bit | 1.2 boolean | CRT |
| 58 | Inputs aux 1/2 - Switching | On/Off | 1 Bit | 1.1 switch | CRT |
| 58 | Inputs aux 1/2 - Shutter movement | Up/Down | 1 Bit | 1.8 up/down | CRT |
| 59 | Input aux 1 - Brightness control | Increase/Decrease | 4 Bit | 3.7 dimming control | CRT |
| 59 | Input aux 1 - Shutter stop/Louvres control | Stop/Step | 1 Bit | 1.7 step | CRT |
| 59 | Input aux 1 - Scene storing trigger | Store | 1 Bit | 1.17 trigger | CW |
| 59 | Inputs aux 1/2 - Brightness control | Increase/Decrease | 4 Bit | 3.7 dimming control | CRT |
| 59 | Inputs aux 1/2 - Shutter stop/Louvres control | Stop/Step | 1 Bit | 1.7 step | CRT |
| 60 | Input aux 2 - Dimmer status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 60 | Input aux 2 - Status feedback | On/Off status | 1 Bit | 1.1 switch | CWTU |
| 60 | Input aux 2 - Movement feedback | Increase/Decrease | 1 Bit | 1.8 up/down | CW |
| 61 | Input aux 2 - 14 byte value | Characters ISO 8859-1 | 14 Bytes | 16.1 Character String (ISO 8859-1) | CRT |
| 61 | Input aux 2 - 1 bit value | 1/0 value | 1 Bit | 1.1 switch | CRT |
| 61 | Input aux 2 - 2 bit value | On/Off forced positioning | 2 Bit | 2.1 switch control | CRT |
| 61 | Input aux 2 - 1 byte value | Unsigned value | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 61 | Input aux 2 - 1 byte value | Signed value | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 61 | Input aux 2 - 1 byte value | % Value | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 61 | Input aux 2 - 1 byte value | HVAC mode | 1 Byte | 20.102 HVAC mode | CRT |
| 61 | Input aux 2 - 2 byte value | Unsigned value | 2 Bytes | 7.1 pulses | CRT |
| 61 | Input aux 2 - 2 byte value | Signed value | 2 Bytes | 8.1 pulses difference | CRT |
| 61 | Input aux 2 - 4 byte value | Unsigned value | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 61 | Input aux 2 - 4 byte value | Signed value | 4 Bytes | 13.1 counter pulses (signed) | CRT |
| 61 | Input aux 2 - Switching | On/Off | 1 Bit | 1.1 switch | CRT |
| 61 | Input aux 2 - Shutter movement | Up/Down | 1 Bit | 1.8 up/down | CRT |
| 61 | Input aux 2 - Scene | Execute/Store | 1 Byte | 18.1 scene control | CRT |
| 62 | Input aux 2 - Brightness control | Increase/Decrease | 4 Bit | 3.7 dimming control | CRT |
| 62 | Input aux 2 - Shutter stop/Louvres control | Stop/Step | 1 Bit | 1.7 step | CRT |
| 62 | Input aux 2 - Scene storing trigger | Store | 1 Bit | 1.17 trigger | CW |