GW10795H

GEWISS · Order number GW10795H · Climate control devices › Thermostats

Download .knxprod Wall mounting KNX thermostat with humidity S 1.2 1.2 · 341 KB

Product

ManufacturerGEWISS
Product nameGW10795H
Order numberGW10795H
Product textKNX Thermostat with humidity - white
HardwareTermostato con umidità KNX - da incasso
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2017-03-15
Languagesde-DE, en-US, es-ES, it-IT
Catalog entryM-0019_H-10795H-0_HP-5308-12-4DC2_CI-GW10795H-0
Fingerprint4DC2
SHA-256f80dc40eb0746e5d5b29c265ebc67a9a2aa60c3465519edd50a8064139ad436a
First seen2026-11-25
Markets59 markets

Application program: Wall mounting KNX thermostat with humidity S 1.2 1.2

Application number$5308
Version1.2
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters1076
Group objects680
Group objects (680)
NoNameFunctionSizeDPTFlags
0Day/Hour inputUpdate day/hour3 Bytes10.1 time of dayCWTU
1Daylight saving time input1= daylight saving/0= standard1 Bit1.1 switchCW
2Enabling slave functionEnable/Disable1 Bit1.3 enableCW
3HVAC mode inputEco/Precom/Comf/Off1 Byte20.102 HVAC modeCW
3Setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
3Setpoint input°K value2 Bytes9.2 temperature difference (K)CW
3Setpoint input°F value2 Bytes9.27 temperature (°F)CW
3Setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
4Setpoint temporary forcing regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
5HVAC off mode inputEnable/Disable1 Bit1.3 enableCW
6HVAC economy mode inputEnable/Disable1 Bit1.3 enableCW
7HVAC precomfort mode inputEnable/Disable1 Bit1.3 enableCW
8HVAC comfort mode inputEnable/Disable1 Bit1.3 enableCW
9Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCW
10Enable dead zoneEnable/Disable1 Bit1.3 enableCW
11Heating anti-freeze setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
11Heating anti-freeze setpoint input°K value2 Bytes9.2 temperature difference (K)CW
11Heating anti-freeze setpoint input°F value2 Bytes9.27 temperature (°F)CW
11Heating anti-freeze setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
12Heating economy setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
12Heating economy setpoint input°K value2 Bytes9.2 temperature difference (K)CW
12Heating economy setpoint input°F value2 Bytes9.27 temperature (°F)CW
12Heating economy setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
13Heating precomfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
13Heating precomfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
13Heating precomfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
13Heating precomfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
14Heating comfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
14Heating comfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
14Heating comfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
14Heating comfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
15Air-cooling high temp. protection setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
15Air-cooling high temp. protection setpoint input°K value2 Bytes9.2 temperature difference (K)CW
15Air-cooling high temp. protection setpoint input°F value2 Bytes9.27 temperature (°F)CW
15Air-cooling high temp. protec. setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
16Air-cooling economy setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
16Air-cooling economy setpoint input°K value2 Bytes9.2 temperature difference (K)CW
16Air-cooling economy setpoint input°F value2 Bytes9.27 temperature (°F)CW
16Air-cooling economy setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
17Air-cooling precomfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
17Air-cooling precomfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
17Air-cooling precomfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
17Air-cooling precomfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
18Air-cooling comfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
18Air-cooling comfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
18Air-cooling comfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
18Air-cooling comfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
19Heating valve switchOn/Off1 Bit1.1 switchCRT
19% command valve heating % Value1 Byte5.1 percentage (0..100%)CRT
19Heating/Air cooling valve switchOn/Off1 Bit1.1 switchCRT
19Heating/air cooling valve % command% Value1 Byte5.1 percentage (0..100%)CRT
20Heating valve status feedbackOn/Off status1 Bit1.1 switchCWTU
20Heating valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
20Heating/air cooling valve status feedbackOn/Off status1 Bit1.1 switchCWTU
20Heating/Air cooling valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
21V1 fan switching heatingOn/Off1 Bit1.1 switchCRT
21% command fancoil speed heating % Value1 Byte5.1 percentage (0..100%)CRT
22V2 fan switching heatingOn/Off1 Bit1.1 switchCRT
23V3 fan switching heatingOn/Off1 Bit1.1 switchCRT
24Heating fan V1 status feedbackOn/Off status1 Bit1.1 switchCWTU
24Heating fancoil speed % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
25Heating fan V2 status feedbackOn/Off status1 Bit1.1 switchCWTU
26Heating fan V3 status feedbackOn/Off status1 Bit1.1 switchCWTU
27Heating 2° stage switchingOn/Off1 Bit1.1 switchCRT
27% command 2° stage heating % Value1 Byte5.1 percentage (0..100%)CRT
28Heating 2° stage feedbackOn/Off status1 Bit1.1 switchCWTU
28Heating 2° stage valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
29Air cooling valve % command% Value1 Byte5.1 percentage (0..100%)CRT
29Air cooling valve switchOn/Off1 Bit1.1 switchCRT
30Air cooling valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
30Air cooling valve status feedbackOn/Off status1 Bit1.1 switchCWTU
31% command fancoil speed air cooling % Value1 Byte5.1 percentage (0..100%)CRT
31V1 fan switching air coolingOn/Off1 Bit1.1 switchCRT
32V2 fan switching air coolingOn/Off1 Bit1.1 switchCRT
33V3 fan switching air coolingOn/Off1 Bit1.1 switchCRT
34Air cooling fancoil speed % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
34Air cooling fan V1 status feedbackOn/Off status1 Bit1.1 switchCWTU
35Air cooling fan V2 status feedbackOn/Off status1 Bit1.1 switchCWTU
36Air cooling fan V3 status feedbackOn/Off status1 Bit1.1 switchCWTU
37% command 2° stage air cooling % Value1 Byte5.1 percentage (0..100%)CRT
37Air cooling 2° stage switchingOn/Off1 Bit1.1 switchCRT
38Air cooling 2° stage valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
38Air cooling 2° stage feedbackOn/Off status1 Bit1.1 switchCWTU
39Fancoil mode inputAutomatic/manual1 Bit1.1 switchCW
40Fan coil mode reportAutomatic/manual1 Bit1.1 switchCRT
41KNX external sensor inputValue °C2 Bytes9.1 temperature (°C)CWTU
41KNX external sensor input°K value2 Bytes9.2 temperature difference (K)CWTU
41KNX external sensor input°F value2 Bytes9.27 temperature (°F)CWTU
41KNX floor sensor inputValue °C2 Bytes9.1 temperature (°C)CWTU
41KNX floor sensor input°K value2 Bytes9.2 temperature difference (K)CWTU
41KNX floor sensor input°F value2 Bytes9.27 temperature (°F)CWTU
42Auxiliary sensor measured temperatureValue °C2 Bytes9.1 temperature (°C)CR
42Auxiliary sensor measured temperature°K value2 Bytes9.2 temperature difference (K)CR
42Auxiliary sensor measured temperature°F value2 Bytes9.27 temperature (°F)CR
42Auxiliary sensor measured temperatureValue °C2 Bytes9.1 temperature (°C)CRT
42Auxiliary sensor measured temperature°K value2 Bytes9.2 temperature difference (K)CRT
42Auxiliary sensor measured temperature°F value2 Bytes9.27 temperature (°F)CRT
43Measured temperatureValue °C2 Bytes9.1 temperature (°C)CR
43Measured temperature°K value2 Bytes9.2 temperature difference (K)CR
43Measured temperature°F value2 Bytes9.27 temperature (°F)CR
43Measured temperatureValue °C2 Bytes9.1 temperature (°C)CRT
43Measured temperature°K value2 Bytes9.2 temperature difference (K)CRT
43Measured temperature°F value2 Bytes9.27 temperature (°F)CRT
44HVAC mode feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCR
44HVAC mode feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
44Functioning setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
44Functioning setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
44Functioning setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
44Functioning setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
44Functioning setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
44Functioning setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
45HVAC off mode feedbackEnable/Disable1 Bit1.3 enableCR
45HVAC off mode feedbackEnable/Disable1 Bit1.3 enableCRT
46HVAC economy mode feedbackEnable/Disable1 Bit1.3 enableCR
46HVAC economy mode feedbackEnable/Disable1 Bit1.3 enableCRT
47HVAC precomfort mode feedbackEnable/Disable1 Bit1.3 enableCR
47HVAC precomfort mode feedbackEnable/Disable1 Bit1.3 enableCRT
48HVAC comfort mode feedbackEnable/Disable1 Bit1.3 enableCR
48HVAC comfort mode feedbackEnable/Disable1 Bit1.3 enableCRT
49Functioning type feedbackHeating/Air cooling1 Bit1.100 heating/coolingCRT
49Functioning type feedbackHeating/Air cooling1 Bit1.100 heating/coolingCR
50Heating anti-freeze setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
50Heating anti-freeze setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
50Heating anti-freeze setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
50Heating anti-freeze setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
50Heating anti-freeze setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
50Heating anti-freeze setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
51Heating economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
51Heating economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
51Heating economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
51Heating economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
51Heating economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
51Heating economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
52Heating precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
52Heating precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
52Heating precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
52Heating precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
52Heating precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
52Heating precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
53Heating comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
53Heating comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
53Heating comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
53Heating comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
53Heating comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
53Heating comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
54Air cond. high temp. protection setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
54Air cond. high temp. protection setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
54Air cond. high temp. protection setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
54Air cond. high temp. protection setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
54Air cond. high temp. protection setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
54Air cond. high temp. protection setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
55Air cooling economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
55Air cooling economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
55Air cooling economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
55Air cooling economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
55Air cooling economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
55Air cooling economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
56Air cooling precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
56Air cooling precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
56Air cooling precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
56Air cooling precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
56Air cooling precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
56Air cooling precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
57Air cooling comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
57Air cooling comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
57Air cooling comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
57Air cooling comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
57Air cooling comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
57Air cooling comfort setpoint feedback°F value2 Bytes9.1 temperature (°C)CR
58Current setpoint report°K value2 Bytes9.2 temperature difference (K)CR
58Current setpoint reportValue °C2 Bytes9.1 temperature (°C)CR
58Current setpoint report°F value2 Bytes9.27 temperature (°F)CR
58Current setpoint reportValue °C2 Bytes9.1 temperature (°C)CRT
58Current setpoint report°K value2 Bytes9.2 temperature difference (K)CRT
58Current setpoint report°F value2 Bytes9.27 temperature (°F)CRT
59Thermostat functioning feedbackSlave/Stand alone1 Bit1.1 switchCR
59Thermostat functioning feedbackSlave/Stand alone1 Bit1.1 switchCRT
60Feedbacks sending triggerSend feedbacks1 Bit1.17 triggerCW
61Thermostat sceneExecute/Store1 Byte18.1 scene controlCW
62Input aux 1 - Dimmer status feedbackOn/Off status1 Bit1.1 switchCWTU
62Input aux 1 - Status feedbackOn/Off status1 Bit1.1 switchCWTU
62Input aux 1 - Movement feedbackIncrease/Decrease1 Bit1.8 up/downCW
63Input aux 1 - 14 byte valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
63Input aux 1 - 1 bit value1/0 value1 Bit1.1 switchCRT
63Input aux 1 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
63Input aux 1 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
63Input aux 1 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
63Input aux 1 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
63Input aux 1 - 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
63Input aux 1 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
63Input aux 1 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
63Input aux 1 - 4 byte valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
63Input aux 1 - 4 byte valueSigned value4 Bytes13.1 counter pulses (signed)CRT
63Input aux 1 - SwitchingOn/Off1 Bit1.1 switchCRT
63Input aux 1 - Shutter movementUp/Down1 Bit1.8 up/downCRT
63Input aux 1 - SceneExecute/Store1 Byte18.1 scene controlCRT
63Input aux 1 - Window status feedbackOpen/Closed1 Bit1.19 window/doorCRT
63Input aux 1 - Window status feedbackOpen/Closed1 Bit1.19 window/doorCR
63Inputs aux 1/2 - SwitchingOn/Off1 Bit1.1 switchCRT
63Inputs aux 1/2 - Shutter movementUp/Down1 Bit1.8 up/downCRT
64Input aux 1 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
64Input aux 1 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
64Input aux 1 - Scene storing triggerStore1 Bit1.17 triggerCW
64Inputs aux 1/2 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
64Inputs aux 1/2 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
65Input aux 2 - Dimmer status feedbackOn/Off status1 Bit1.1 switchCWTU
65Input aux 2 - Status feedbackOn/Off status1 Bit1.1 switchCWTU
65Input aux 2 - Movement feedbackIncrease/Decrease1 Bit1.8 up/downCW
66Input aux 2 - 14 byte valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
66Input aux 2 - 1 bit value1/0 value1 Bit1.1 switchCRT
66Input aux 2 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
66Input aux 2 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
66Input aux 2 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
66Input aux 2 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
66Input aux 2 - 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
66Input aux 2 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
66Input aux 2 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
66Input aux 2 - 4 byte valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
66Input aux 2 - 4 byte valueSigned value4 Bytes13.1 counter pulses (signed)CRT
66Input aux 2 - SwitchingOn/Off1 Bit1.1 switchCRT
66Input aux 2 - Shutter movementUp/Down1 Bit1.8 up/downCRT
66Input aux 2 - SceneExecute/Store1 Byte18.1 scene controlCRT
67Input aux 2 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
67Input aux 2 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
67Input aux 2 - Scene storing triggerStore1 Bit1.17 triggerCW
68Output aux - StatusOn/Off1 Bit1.1 switchCR
68Output aux - StatusOn/Off1 Bit1.1 switchCRT
69Output aux - SwitchingOn/Off1 Bit1.1 switchCW
70Output aux - Timed switchingStart/Stop1 Bit1.10 start/stopCW
71Output aux - Priority commandOn/Off forced positioning2 Bit2.1 switch controlCW
72Output aux - SceneExecute/Store1 Byte18.1 scene controlCW
73Setpoint regulation range settingValue °C2 Bytes9.1 temperature (°C)CW
74Device 1 - Send HVAC modeEco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
74Device 1 - Setpoint sendingValue °C2 Bytes9.1 temperature (°C)CRT
74Device 1 - Setpoint sending°K value2 Bytes9.2 temperature difference (K)CRT
74Device 1 - Setpoint sending°F value2 Bytes9.27 temperature (°F)CRT
75Device 1 - Send functioning typeHeating/Air cooling1 Bit1.100 heating/coolingCRT
76Device 1 - Functioning type status feedbackHeating/Air cooling1 Bit1.100 heating/coolingCWTU
77Device 1 - HVAC mode status feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
77Device 1 - Reference setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
77Device 1 - Reference setpoint input°K value2 Bytes9.2 temperature difference (K)CW
77Device 1 - Reference setpoint input°F value2 Bytes9.1 temperature (°C)CW
78Device 1 - Setpoint status feedbackValue °C2 Bytes9.1 temperature (°C)CWTU
78Device 1 - Setpoint status feedback°K value2 Bytes9.2 temperature difference (K)CWTU
78Device 1 - Setpoint status feedback°F value2 Bytes9.27 temperature (°F)CWTU
79Device 1 - Measured temperature status feedbackValue °C2 Bytes9.1 temperature (°C)CWTU
79Device 1 - Measured temperature status feedback°K value2 Bytes9.2 temperature difference (K)CWTU
79Device 1 - Measured temperature status feedback°F value2 Bytes9.27 temperature (°F)CWTU
80Device 1 - Measured relative humidity feedbackValue [% RH]2 Bytes9.7 humidity (%)CWTU
81Device 2 - Setpoint sendingValue °C2 Bytes9.1 temperature (°C)CRT
81Device 2 - Setpoint sending°K value2 Bytes9.2 temperature difference (K)CRT
81Device 2 - Setpoint sending°F value2 Bytes9.27 temperature (°F)CRT
81Device 2 - Send HVAC modeEco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
82Device 2 - Send functioning typeHeating/Air cooling1 Bit1.100 heating/coolingCRT
83Device 2 - Functioning type status feedbackHeating/Air cooling1 Bit1.100 heating/coolingCWTU
84Device 2 - HVAC mode status feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
84Device 2 - Reference setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
84Device 2 - Reference setpoint input°K value2 Bytes9.2 temperature difference (K)CW
84Device 2 - Reference setpoint input°F value2 Bytes9.1 temperature (°C)CW
85Device 2 - Setpoint status feedbackValue °C2 Bytes9.1 temperature (°C)CWTU
85Device 2 - Setpoint status feedback°K value2 Bytes9.2 temperature difference (K)CWTU
85Device 2 - Setpoint status feedback°F value2 Bytes9.27 temperature (°F)CWTU
86Device 2 - Measured temperature status feedbackValue °C2 Bytes9.1 temperature (°C)CWTU
86Device 2 - Measured temperature status feedback°K value2 Bytes9.2 temperature difference (K)CWTU
86Device 2 - Measured temperature status feedback°F value2 Bytes9.27 temperature (°F)CWTU
87Device 2 - Measured relative humidity feedbackValue [% RH]2 Bytes9.7 humidity (%)CWTU
88Device 3 - Send HVAC modeEco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
88Device 3 - Setpoint sendingValue °C2 Bytes9.1 temperature (°C)CRT
88Device 3 - Setpoint sending°K value2 Bytes9.2 temperature difference (K)CRT
88Device 3 - Setpoint sending°F value2 Bytes9.27 temperature (°F)CRT
89Device 3 - Send functioning typeHeating/Air cooling1 Bit1.100 heating/coolingCRT
90Device 3 - Functioning type status feedbackHeating/Air cooling1 Bit1.100 heating/coolingCWTU
91Device 3 - HVAC mode status feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
91Device 3 - Reference setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
91Device 3 - Reference setpoint input°K value2 Bytes9.2 temperature difference (K)CW
91Device 3 - Reference setpoint input°F value2 Bytes9.1 temperature (°C)CW
92Device 3 - Setpoint status feedbackValue °C2 Bytes9.1 temperature (°C)CWTU
92Device 3 - Setpoint status feedback°K value2 Bytes9.2 temperature difference (K)CWTU
92Device 3 - Setpoint status feedback°F value2 Bytes9.27 temperature (°F)CWTU
93Device 3 - Measured temperature status feedbackValue °C2 Bytes9.1 temperature (°C)CWTU
93Device 3 - Measured temperature status feedback°K value2 Bytes9.2 temperature difference (K)CWTU
93Device 3 - Measured temperature status feedback°F value2 Bytes9.27 temperature (°F)CWTU
94Device 3 - Measured relative humidity feedbackValue [% RH]2 Bytes9.7 humidity (%)CWTU
95Device 4 - Send HVAC modeEco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
95Device 4 - Setpoint sendingValue °C2 Bytes9.1 temperature (°C)CRT
95Device 4 - Setpoint sending°K value2 Bytes9.2 temperature difference (K)CRT
95Device 4 - Setpoint sending°F value2 Bytes9.27 temperature (°F)CRT
96Device 4 - Send functioning typeHeating/Air cooling1 Bit1.100 heating/coolingCRT
97Device 4 - Functioning type status feedbackHeating/Air cooling1 Bit1.100 heating/coolingCWTU
98Device 4 - HVAC mode status feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
98Device 4 - Reference setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
98Device 4 - Reference setpoint input°K value2 Bytes9.2 temperature difference (K)CW
98Device 4 - Reference setpoint input°F value2 Bytes9.1 temperature (°C)CW
99Device 4 - Setpoint status feedbackValue °C2 Bytes9.1 temperature (°C)CWTU
99Device 4 - Setpoint status feedback°K value2 Bytes9.2 temperature difference (K)CWTU
99Device 4 - Setpoint status feedback°F value2 Bytes9.27 temperature (°F)CWTU
100Device 4 - Measured temperature status feedbackValue °C2 Bytes9.1 temperature (°C)CWTU
100Device 4 - Measured temperature status feedback°K value2 Bytes9.2 temperature difference (K)CWTU
100Device 4 - Measured temperature status feedback°F value2 Bytes9.27 temperature (°F)CWTU
101Device 4 - Measured relative humidity feedbackValue [% RH]2 Bytes9.7 humidity (%)CWTU
102Humidity external sensor inputValue [% RH]2 Bytes9.7 humidity (%)CWTU
103Relative humidity measuredValue [% RH]2 Bytes9.7 humidity (%)CRT
103Relative humidity measuredValue [% RH]2 Bytes9.7 humidity (%)CR
104Relative humidity estimatedValue [% RH]2 Bytes9.7 humidity (%)CRT
104Relative humidity estimatedValue [% RH]2 Bytes9.7 humidity (%)CR
105Specific humidityValue [g/kg]4 Bytes14.5 amplitudeCRT
105Specific humidityValue [g/kg]4 Bytes14.5 amplitudeCR
106Dew point temperatureValue [°C]2 Bytes9.1 temperature (°C)CRT
106Dew point temperatureValue [°K]2 Bytes9.2 temperature difference (K)CRT
106Dew point temperatureValue [°F]2 Bytes9.27 temperature (°F)CRT
106Dew point temperatureValue [°C]2 Bytes9.1 temperature (°C)CR
106Dew point temperatureValue [°K]2 Bytes9.2 temperature difference (K)CR
106Dew point temperatureValue [°F]2 Bytes9.27 temperature (°F)CR
107Dew point temperature alarm enablingEnable/Disable1 Bit1.2 booleanCW
108Dew point temperature alarm enabling statusEnabled/Disabled1 Bit1.3 enableCRT
109Dew point temperature alarm limit regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
110Dew point temperature alarm threshold feedbackValue [°C]2 Bytes9.1 temperature (°C)CRT
110Dew point temperature alarm threshold feedbackValue [°K]2 Bytes9.2 temperature difference (K)CRT
110Dew point temperature alarm threshold feedbackValue [°F]2 Bytes9.27 temperature (°F)CRT
111Dew point temperature alarm output1/0 value1 Bit1.1 switchCRT
111Dew point temperature alarm outputOn/Off forced positioning2 Bit2.1 switch controlCRT
111Dew point temperature alarm outputValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
111Dew point temperature alarm outputValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
111Dew point temperature alarm outputValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
111Dew point temperature alarm outputHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
111Dew point temperature alarm outputValue [0 .. 65535]2 Bytes7.1 pulsesCRT
111Dew point temperature alarm outputValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
112Relative humidity threshold 1 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
112Relative humidity threshold 1 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
113Relative humidity threshold 1 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
114Relative humidity threshold 1 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
114Relative humidity threshold 1 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
115Relative humidity threshold 1 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
116Relative humidity threshold 1 output A1/0 value1 Bit1.1 switchCRT
116Relative humidity threshold 1 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
116Relative humidity threshold 1 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
116Relative humidity threshold 1 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
116Relative humidity threshold 1 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
116Relative humidity threshold 1 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
116Relative humidity threshold 1 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
116Relative humidity threshold 1 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
116Relative humidity threshold 1 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
116Relative humidity threshold 1 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
116Relative humidity threshold 1 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
117Relative humidity threshold 1 output A statusOn/Off status1 Bit1.1 switchCWTU
117Output A relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
117Output A relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
117Output A relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
117Output A relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
118Relative humidity threshold 1 output B1/0 value1 Bit1.1 switchCRT
118Relative humidity threshold 1 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
118Relative humidity threshold 1 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
118Relative humidity threshold 1 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
118Relative humidity threshold 1 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
118Relative humidity threshold 1 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
118Relative humidity threshold 1 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
118Relative humidity threshold 1 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
118Relative humidity threshold 1 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
118Relative humidity threshold 1 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
118Relative humidity threshold 1 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
119Relative humidity threshold 1 output B statusOn/Off status1 Bit1.1 switchCWTU
119Output B relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
119Output B relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
119Output B relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
119Output B relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
120Relative humidity threshold 1 output C1/0 value1 Bit1.1 switchCRT
120Relative humidity threshold 1 output COn/Off forced positioning2 Bit2.1 switch controlCRT
120Relative humidity threshold 1 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
120Relative humidity threshold 1 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
120Relative humidity threshold 1 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
120Relative humidity threshold 1 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
120Relative humidity threshold 1 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
120Relative humidity threshold 1 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
120Relative humidity threshold 1 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
120Relative humidity threshold 1 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
120Relative humidity threshold 1 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
121Relative humidity threshold 1 output C statusOn/Off status1 Bit1.1 switchCWTU
121Output C relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
121Output C relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
121Output C relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
121Output C relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
122Relative humidity threshold 1 output D1/0 value1 Bit1.1 switchCRT
122Relative humidity threshold 1 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
122Relative humidity threshold 1 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
122Relative humidity threshold 1 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
122Relative humidity threshold 1 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
122Relative humidity threshold 1 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
122Relative humidity threshold 1 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
122Relative humidity threshold 1 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
122Relative humidity threshold 1 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
122Relative humidity threshold 1 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
122Relative humidity threshold 1 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
123Relative humidity threshold 1 output D statusOn/Off status1 Bit1.1 switchCWTU
123Output D relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
123Output D relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
123Output D relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
123Output D relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
124Relative humidity threshold 2 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
124Relative humidity threshold 2 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
125Relative humidity threshold 2 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
126Relative humidity threshold 2 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
126Relative humidity threshold 2 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
127Relative humidity threshold 2 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
128Relative humidity threshold 2 output A1/0 value1 Bit1.1 switchCRT
128Relative humidity threshold 2 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
128Relative humidity threshold 2 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
128Relative humidity threshold 2 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
128Relative humidity threshold 2 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
128Relative humidity threshold 2 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
128Relative humidity threshold 2 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
128Relative humidity threshold 2 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
128Relative humidity threshold 2 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
128Relative humidity threshold 2 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
128Relative humidity threshold 2 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
129Relative humidity threshold 2 output A statusOn/Off status1 Bit1.1 switchCWTU
129Output A relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
129Output A relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
129Output A relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
129Output A relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
130Relative humidity threshold 2 output B1/0 value1 Bit1.1 switchCRT
130Relative humidity threshold 2 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
130Relative humidity threshold 2 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
130Relative humidity threshold 2 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
130Relative humidity threshold 2 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
130Relative humidity threshold 2 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
130Relative humidity threshold 2 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
130Relative humidity threshold 2 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
130Relative humidity threshold 2 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
130Relative humidity threshold 2 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
130Relative humidity threshold 2 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
131Relative humidity threshold 2 output B statusOn/Off status1 Bit1.1 switchCWTU
131Output B relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
131Output B relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
131Output B relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
131Output B relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
132Relative humidity threshold 2 output C1/0 value1 Bit1.1 switchCRT
132Relative humidity threshold 2 output COn/Off forced positioning2 Bit2.1 switch controlCRT
132Relative humidity threshold 2 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
132Relative humidity threshold 2 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
132Relative humidity threshold 2 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
132Relative humidity threshold 2 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
132Relative humidity threshold 2 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
132Relative humidity threshold 2 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
132Relative humidity threshold 2 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
132Relative humidity threshold 2 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
132Relative humidity threshold 2 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
133Relative humidity threshold 2 output C statusOn/Off status1 Bit1.1 switchCWTU
133Output C relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
133Output C relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
133Output C relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
133Output C relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
134Relative humidity threshold 2 output D1/0 value1 Bit1.1 switchCRT
134Relative humidity threshold 2 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
134Relative humidity threshold 2 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
134Relative humidity threshold 2 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
134Relative humidity threshold 2 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
134Relative humidity threshold 2 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
134Relative humidity threshold 2 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
134Relative humidity threshold 2 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
134Relative humidity threshold 2 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
134Relative humidity threshold 2 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
134Relative humidity threshold 2 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
135Relative humidity threshold 2 output D statusOn/Off status1 Bit1.1 switchCWTU
135Output D relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
135Output D relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
135Output D relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
135Output D relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
136Relative humidity threshold 3 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
136Relative humidity threshold 3 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
137Relative humidity threshold 3 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
138Relative humidity threshold 3 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
138Relative humidity threshold 3 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
139Relative humidity threshold 3 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
140Relative humidity threshold 3 output A1/0 value1 Bit1.1 switchCRT
140Relative humidity threshold 3 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
140Relative humidity threshold 3 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
140Relative humidity threshold 3 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
140Relative humidity threshold 3 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
140Relative humidity threshold 3 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
140Relative humidity threshold 3 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
140Relative humidity threshold 3 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
140Relative humidity threshold 3 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
140Relative humidity threshold 3 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
140Relative humidity threshold 3 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
141Relative humidity threshold 3 output A statusOn/Off status1 Bit1.1 switchCWTU
141Output A relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
141Output A relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
141Output A relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
141Output A relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
142Relative humidity threshold 3 output B1/0 value1 Bit1.1 switchCRT
142Relative humidity threshold 3 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
142Relative humidity threshold 3 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
142Relative humidity threshold 3 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
142Relative humidity threshold 3 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
142Relative humidity threshold 3 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
142Relative humidity threshold 3 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
142Relative humidity threshold 3 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
142Relative humidity threshold 3 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
142Relative humidity threshold 3 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
142Relative humidity threshold 3 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
143Relative humidity threshold 3 output B statusOn/Off status1 Bit1.1 switchCWTU
143Output B relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
143Output B relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
143Output B relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
143Output B relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
144Relative humidity threshold 3 output C1/0 value1 Bit1.1 switchCRT
144Relative humidity threshold 3 output COn/Off forced positioning2 Bit2.1 switch controlCRT
144Relative humidity threshold 3 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
144Relative humidity threshold 3 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
144Relative humidity threshold 3 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
144Relative humidity threshold 3 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
144Relative humidity threshold 3 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
144Relative humidity threshold 3 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
144Relative humidity threshold 3 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
144Relative humidity threshold 3 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
144Relative humidity threshold 3 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
145Relative humidity threshold 3 output C statusOn/Off status1 Bit1.1 switchCWTU
145Output C relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
145Output C relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
145Output C relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
145Output C relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
146Relative humidity threshold 3 output D1/0 value1 Bit1.1 switchCRT
146Relative humidity threshold 3 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
146Relative humidity threshold 3 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
146Relative humidity threshold 3 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
146Relative humidity threshold 3 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
146Relative humidity threshold 3 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
146Relative humidity threshold 3 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
146Relative humidity threshold 3 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
146Relative humidity threshold 3 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
146Relative humidity threshold 3 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
146Relative humidity threshold 3 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
147Relative humidity threshold 3 output D statusOn/Off status1 Bit1.1 switchCWTU
147Output D relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
147Output D relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
147Output D relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
147Output D relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
148Relative humidity threshold 4 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
148Relative humidity threshold 4 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
149Relative humidity threshold 4 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
150Relative humidity threshold 4 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
150Relative humidity threshold 4 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
151Relative humidity threshold 4 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
152Relative humidity threshold 4 output A1/0 value1 Bit1.1 switchCRT
152Relative humidity threshold 4 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
152Relative humidity threshold 4 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
152Relative humidity threshold 4 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
152Relative humidity threshold 4 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
152Relative humidity threshold 4 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
152Relative humidity threshold 4 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
152Relative humidity threshold 4 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
152Relative humidity threshold 4 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
152Relative humidity threshold 4 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
152Relative humidity threshold 4 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
153Relative humidity threshold 4 output A statusOn/Off status1 Bit1.1 switchCWTU
153Output A relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
153Output A relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
153Output A relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
153Output A relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
154Relative humidity threshold 4 output B1/0 value1 Bit1.1 switchCRT
154Relative humidity threshold 4 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
154Relative humidity threshold 4 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
154Relative humidity threshold 4 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
154Relative humidity threshold 4 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
154Relative humidity threshold 4 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
154Relative humidity threshold 4 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
154Relative humidity threshold 4 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
154Relative humidity threshold 4 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
154Relative humidity threshold 4 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
154Relative humidity threshold 4 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
155Relative humidity threshold 4 output B statusOn/Off status1 Bit1.1 switchCWTU
155Output B relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
155Output B relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
155Output B relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
155Output B relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
156Relative humidity threshold 4 output C1/0 value1 Bit1.1 switchCRT
156Relative humidity threshold 4 output COn/Off forced positioning2 Bit2.1 switch controlCRT
156Relative humidity threshold 4 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
156Relative humidity threshold 4 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
156Relative humidity threshold 4 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
156Relative humidity threshold 4 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
156Relative humidity threshold 4 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
156Relative humidity threshold 4 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
156Relative humidity threshold 4 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
156Relative humidity threshold 4 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
156Relative humidity threshold 4 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
157Relative humidity threshold 4 output C statusOn/Off status1 Bit1.1 switchCWTU
157Output C relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
157Output C relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
157Output C relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
157Output C relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
158Relative humidity threshold 4 output D1/0 value1 Bit1.1 switchCRT
158Relative humidity threshold 4 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
158Relative humidity threshold 4 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
158Relative humidity threshold 4 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
158Relative humidity threshold 4 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
158Relative humidity threshold 4 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
158Relative humidity threshold 4 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
158Relative humidity threshold 4 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
158Relative humidity threshold 4 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
158Relative humidity threshold 4 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
158Relative humidity threshold 4 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
159Relative humidity threshold 4 output D statusOn/Off status1 Bit1.1 switchCWTU
159Output D relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
159Output D relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
159Output D relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
159Output D relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
160Relative humidity threshold 5 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
160Relative humidity threshold 5 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
161Relative humidity threshold 5 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
162Relative humidity threshold 5 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
162Relative humidity threshold 5 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
163Relative humidity threshold 5 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
164Relative humidity threshold 5 output A1/0 value1 Bit1.1 switchCRT
164Relative humidity threshold 5 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
164Relative humidity threshold 5 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
164Relative humidity threshold 5 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
164Relative humidity threshold 5 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
164Relative humidity threshold 5 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
164Relative humidity threshold 5 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
164Relative humidity threshold 5 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
164Relative humidity threshold 5 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
164Relative humidity threshold 5 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
164Relative humidity threshold 5 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
165Relative humidity threshold 5 output A statusOn/Off status1 Bit1.1 switchCWTU
165Output A relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
165Output A relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
165Output A relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
165Output A relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
166Relative humidity threshold 5 output B1/0 value1 Bit1.1 switchCRT
166Relative humidity threshold 5 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
166Relative humidity threshold 5 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
166Relative humidity threshold 5 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
166Relative humidity threshold 5 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
166Relative humidity threshold 5 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
166Relative humidity threshold 5 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
166Relative humidity threshold 5 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
166Relative humidity threshold 5 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
166Relative humidity threshold 5 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
166Relative humidity threshold 5 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
167Relative humidity threshold 5 output B statusOn/Off status1 Bit1.1 switchCWTU
167Output B relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
167Output B relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
167Output B relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
167Output B relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
168Relative humidity threshold 5 output C1/0 value1 Bit1.1 switchCRT
168Relative humidity threshold 5 output COn/Off forced positioning2 Bit2.1 switch controlCRT
168Relative humidity threshold 5 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
168Relative humidity threshold 5 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
168Relative humidity threshold 5 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
168Relative humidity threshold 5 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
168Relative humidity threshold 5 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
168Relative humidity threshold 5 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
168Relative humidity threshold 5 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
168Relative humidity threshold 5 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
168Relative humidity threshold 5 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
169Relative humidity threshold 5 output C statusOn/Off status1 Bit1.1 switchCWTU
169Output C relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
169Output C relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
169Output C relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
169Output C relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
170Relative humidity threshold 5 output D1/0 value1 Bit1.1 switchCRT
170Relative humidity threshold 5 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
170Relative humidity threshold 5 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
170Relative humidity threshold 5 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
170Relative humidity threshold 5 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
170Relative humidity threshold 5 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
170Relative humidity threshold 5 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
170Relative humidity threshold 5 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
170Relative humidity threshold 5 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
170Relative humidity threshold 5 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
170Relative humidity threshold 5 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
171Relative humidity threshold 5 output D statusOn/Off status1 Bit1.1 switchCWTU
171Output D relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
171Output D relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
171Output D relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
171Output D relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
172Season selection input1=Summer / 0=Winter1 Bit1.2 booleanCWTU
172Season selection input1=Winter / 0=Summer1 Bit1.2 booleanCWTU
173Thermal comfort status feedback1=Comfortable/0=Uncomfortable1 Bit1.2 booleanCRT
Parameters (271)
ParameterTypeDefault
ETS downloadlistBB
Thermostat functioningliststand alone
Parameters local modificationlistdisabled
Stand alone control typelistHVAC mode
Functioning type settinglistby local command or from bus
Remote parameters settinglistdisable
- Commands format for HVAC mode settinglist1 byte
-- Reception 1 bit mode con priority > actuallistkeep lower priority objects value
-- Reception 1 bit mode con priority < actuallistupdate object value
- HVAC mode setpoint modification via buslistdisable
- Setpoint regulation step [0.1°C]unsignedInt 1…205
- Temporary setpoint forcing via buslistdisable
-- Setpoint temporary forcing regulation step [0.1°C]unsignedInt 1…205
- Set functioning typelistdisable
Change the functioning setpoint via bus throughlistabsolute value setting (°C)
Allows local switching offlistdisable
- Reactivate device bylistlocal control only
Master/Slave control typelistHVAC mode
Input contacts functionlisttwo auxiliary inputs independent
Day and Hour modification via buslistdisable
Automatic change Daylight Saving Time/Standard Timelistdisable
- Daylight saving time input object value at downloadliststandard time
Control logic Heating/Air coolinglistdifferent (4 pipe)
Heating/Air cooling control algorithmlisttwo points ON-OFF
Heating/air cooling valve status feedbacklistenable
- Commands repetition period with disabled feedbacklist5 minutes
Ripeti comando su cambiamento stato attuatore RISClistenable
Fancoil valves managementlisttwo points ON-OFF
- Heating/air cooling valve status feedbacklistenable
-- Commands repetition period with disabled feedbacklist5 minutes
Fancoil speed modification via buslistdisable
Fancoil mode (automatic/manual) feedbacklistdisable
Heating control algorithmlisttwo points ON-OFF
Air cooling control algorithmlisttwo points ON-OFF
Regulation differential (tenth of °C)unsignedInt 1…202
Select heating systemlistfloor heating
- Proportional bandlist2.0 °C
- Integration timelist60 minutes
- Cycle timelist30 minutes
- Min. % variation for continuous command sendinglist5%
Fancoil speed numberlist3
- Regulation differential speed 1 (tenth of °C)unsignedInt 0…202
- Speed 1 inertia time (seconds)unsignedInt 0…100
Fancoil speed status feedbacklistenable
- Command repetition time fancoil speedlist5 minutes
- Regulation differential speed 2 (tenth of °C)unsignedInt 1…202
- Speed 2 inertia time (seconds)unsignedInt 0…100
- Regulation differential speed 3 (tenth of °C)unsignedInt 1…202
- Speed 3 inertia time (seconds)unsignedInt 0…100
Regulation differential valve (tenth of °C)unsignedInt 1…202
Heating 2° stagelistdisabled
- Operation limit 2° stage (tenths of °C)unsignedInt 10…10010
- Regulation differential 2° stage (tenth of °C)unsignedInt 1…202
Heating 2° stage feedbacklistenable
- Command repetition time 2° stage without feedbacklist5 minutes
Ripeti comando su cambiamento stato 2° stadio RISClistenable
Heating valve status feedbacklistenable
- Regulation differential valve (tenth of °C)unsignedInt 1…202
- Heating valve status feedbacklistenable
Select air cooling systemlistceiling cooling
- Proportional bandlist5.0 °C
- Integration timelist240 minutes
air cooling 2° stagelistdisabled
Air cooling 2° stage feedbacklistenable
Ripeti comando su cambiamento stato 2° stadio CONDlistenable
Air cooling valve status feedbacklistenable
Ripeti comando su cambiamento stato attuatore CONDlistenable
- Air cooling valve status feedbacklistenable
Comfort setpoint (tenths of °C)signedInt 50…400200
Precomfort setpoint (tenths of °C)signedInt 50…400180
Economy setpoint (tenths of °C)signedInt 50…400160
Antifreeze setpoint (tenths of °C)signedInt 20…7050
Comfort setpoint (tenths of °C)signedInt 50…400240
Precomfort setpoint (tenths of °C)signedInt 50…400260
Economy setpoint (tenths of °C)signedInt 50…400280
High temperature protection setpoint (tenths of °C)signedInt 300…400350
Temperature forcing behaviour at new setpoint receivinglistcancel temperature forcing
Setpoint variation range for manual forcing via buslist± 3.0
Setpoint variation range input for manual forcing via buslistdisable
modify all the setpoints of the same functioning typelistno
modify contemporary the setpoint of the other functioning typelistno
Functioning setpoint (tenths of °C)signedInt 50…400200
Antifreeze setpoint after manual switching off (tenths of °C)signedInt 20…7050
Functioning setpoint (tenths of °C)signedInt 50…400240
Internal sensor correction factor (tenths of °C)signedInt -20…200
KNX external sensorlistdisabled
- Measure unit KNX external sensorlistCelsius degrees (°C)
- KNX ext. sensor incidence in measured temp. calculationlist10%
- KNX external sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
- Behaviour at KNX external sensor signal absencelistuse last value received
- KNX floor sensor measure unitlistCelsius degrees (°C)
- Threshold temperature temperature alarm (tenth of °C)unsignedInt 150…1000500
- Temperature alarm hysteresis (tenth of °C)unsignedInt 10…10030
- KNX floor sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
- Behaviour at KNX floor sensor signal absencelistactivate temperature alarm
Auxiliary external sensorlistexternal sensor
- Type of NTC sensor connectedlistfloating sensor (GW10800)
- Correction factor auxiliary sensor (tenths of °C)signedInt -20…200
- Auxiliary ext. sensor incidence in measured temp. calculationlist10%
- Behaviour at auxiliary external sensor signal absencelistuse last value received
Auxiliary sensor measured temperaturelistdo not send
-- Measure unit auxiliary sensorlistCelsius degrees (°C)
-- Auxiliary sensor temperature min. variation for sending value [± 0.1 °C]unsignedInt 1…105
-- Auxiliary sensor temperature sending period [minutes]unsignedInt 1…2555
- Behaviour at auxiliary floor sensor signal absencelistactivate temperature alarm
- Temperature measured by auxiliary floor sensorlistdo not send
Measured temperaturelistdo not send
- Measure unitlistCelsius degrees (°C)
- Minimum variation for sending value [± 0.1 °C]unsignedInt 1…105
- Temperature sending period [minutes]unsignedInt 1…2555
HVAC mode feedbacklistdisabled
- 1 bit HVAC modeliston demand only
- 1 byte HVAC modeliston demand only
Functioning setpoint feedbacklistdisabled
Functioning type feedbacklistdisabled
Current setpoint reportlistdisabled
Thermostat functioning feedbacklistdisabled
HVAC mode setpoint feedbacklistdisabled
Feedbacks sending trigger objectlistdisable
Scenes functionlistdisable
Scene number 1listunassigned
Scene number 2listunassigned
Scene number 3listunassigned
Scene number 4listunassigned
Scene number 5listunassigned
Scene number 6listunassigned
Scene number 7listunassigned
Scene number 8listunassigned
Parameters to memorize while storinglistHVAC mode only
Parameters to memorize while storinglistsetpoint only
KNX thermoregulation devices remote controllistdisabled
Device 1 control typelistHVAC mode
- Input temperature object measure unitlistCelsius degrees (°C)
- Remote device setpoint variation rangelistunlimited
- Input/output temperature object measure unitlistCelsius degrees (°C)
-- Remote device setpoint variation limitlist± 3.0
Device 2 control typelistHVAC mode
Device 3 control typelistHVAC mode
Device 4 control typelistHVAC mode
Temperature measure unitlistCelsius degrees (°C)
Temperature and humidity alternating display on the thermostat pagelistdisabled
Automatically back to main page after timeoutlistdisabled
- Idle time for automatic return to main pagelist30 seconds
Backlight colourlistwhite
Icons themelistmonochrome
- Icons colour with backlight onlistblue
Retroilluminazione displaylisttimed activation (energy saving)
Backlight deactivation timeout (seconds)unsignedInt 10…18020
Display backlight brightness intensity islistmanually settable
Backlight brightness intensity percentage valuelist80%
- Backlight brightness offset compared to twilight controllist0%
Matched functionlistnone
Sending object formatlist1 bit
- Sending on contact closing detectionlist1
- Sending on contact opening detectionlistno effect
-- Status feedback objectlistdisabled
- Sending on contact closing detectionlistactivate on (down) forcing
- Sending on contact closing detectionlistvalue sending
-- Value (0 .. 255)unsignedInt 0…2550
-- Value (-128 .. +127)signedInt -128…1270
-- Value (0% .. 100%)unsignedInt 0…1000
- Sending on contact closing detectionlistcomfort
-- Value (0 .. 65535)unsignedInt 0…655350
-- Value (-32768 .. +32767)signedInt -32768…327670
-- Value (0 .. 4294967295)unsignedInt 0…42949672950
-- Value (-2147483648 .. +2147483647)signedInt -2147483648…21474836470
-- Value (characters ISO 8859-1)text
- Sending on short operation detectionlist1
- Sending on long operation detectionlistno effect
- Sending on short operation detectionlistvalue sending
- Sending on short operation detectionlistcomfort
Dimmer status feedback objectlistdisable
- Brightness dimming commands with dimmer onlistbrightness increase and decrease
Increase/decrease steplist12.5%
Cyclical sending period [x 0.1s]unsignedInt 3…505
Scene number (0 .. 63)unsignedInt 0…630
Scene storing by long operationlistenabled
Window statuslistclosed if contact is open
Send window contact status feedbacklistdisabled
Matched functionlistdimming with STOP telegram
Uso relè localelistfree
Status information transmissionlistsending on change
- Status transmission on bus voltage recoverylistenable
Relay status at bus voltage failurelistno change
Relay status after bus voltage recoverylistas before voltage drop
- Activation timelist1 min
- Warning timelistno warning
- Relay status on forced positioning endlistfollows last command received
- Forced positioning status at bus voltage recoverylistas before voltage drop
Fattore di correzione sensore interno [% UR]signedInt -10…100
Sensore esterno di umidità KNXlistenable
- Incidenza del sensore esterno KNX nel calcolo dell'umidità misuratalist100%
KNX external sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
Behaviour at KNX external sensor signal absencelistuse last value received
Relative humidity measuredlistdo not send
- Minimum variation for sending value [% RH]list± 5 %
- Relative humidity value repetition time [minutes]unsignedInt 1…2555
Estimate the humidity at the temperature measured by the thermostatlistdisable
- Estimated relative humiditylistdo not send
-- Minimum variation for sending value [% RH]list± 5 %
-- Estimated relative humidity value repetition time [minutes]unsignedInt 1…2555
Specific humiditylistdo not send
- Minimum variation for sending valuelist± 5 g/Kg
- Specific relative humidity value repetition time [minutes]unsignedInt 1…2555
Relative humidity threshold 1listdisable
Measure used as reference:listRelative humidity measured
Threshold logic functioning:listhumidification
C1 = Condition 1listRelative humidity <= Limit threshold - hysteresis
C2 = Condition 2listRelative humidity >= Limit threshold
C1 = Condition 1listRelative humidity >= Limit threshold + hysteresis
C2 = Condition 2listRelative humidity <= Limit threshold
Limit threshold starting value [% RH]unsignedInt 0…10050
Limit threshold hysteresis [% RH]unsignedInt 1…205
Change the threshold value via bus throughlistabsolute value
- Threshold regulation step via bus [%]unsignedInt 1…205
Enable/disable the humidity threshold (via bus and device menu)listno
- Threshold activation valuelistvalue "1"
- Threshold activation status after bus voltage recoverylistas before voltage drop
Oggetto A --------------------------------------listenable
Output formatlist1 bit
- On the occurrence of Condition 1listsends 1
- On the occurrence of Condition 2listno effect
- Relative humidity threshold output status feedbacklistenable
- Output commands cyclical repetitionlistdisable
-- Command repetition timelist5 minutes
- On the occurrence of Condition 1listsends active forcing on(down)
- On the occurrence of Condition 1listvalue sending
- On the occurrence of Condition 1listsends comfort
-- Offset (-3 .. 3)signedInt -3…31
- On the occurrence of Condition 1listsends current setpoint ± offset
-- Offset [0.1°C] (-300 .. 300)signedInt -300…30010
Object B --------------------------------------listdisable
Object C --------------------------------------listdisable
Object D --------------------------------------listdisable
Relative humidity threshold 2listdisable
Relative humidity threshold 3listdisable
Relative humidity threshold 4listdisable
Relative humidity threshold 5listdisable
Dew point temperaturelistdo not send
- Feedback measure unitlistCelsius degrees (°C)
- Sending feedback repetition time [minutes]unsignedInt 1…2555
Dew point temperature alarm feedback thresholdlistdisable
- Alarm feedback limit [tenths of °C]unsignedInt 0…10050
- Alarm feedback limit regulation step via bus [0.1°C]unsignedInt 1…1005
- Alarm threshold hysteresis [tenths of °C]unsignedInt 1…2010
- Alarm threshold feedback measure unitlistCelsius degrees (°C)
- Enable/disable the alarm threshold (via bus and device menu)listno
-- Threshold activation valuelistvalue "1"
-- Alarm threshold activation status after bus voltage recoverylistas before voltage drop
- Output formatlist1 bit
-- If Measure temperature < Threshold temperaturelistsends 1
-- If Measure temperature > Threshold temperature + Hysteresislistno effect
-- If Measure temperature < Threshold temperaturelistsends active forcing on(down)
-- If Measure temperature < Threshold temperaturelistvalue sending
--- Value (0 .. 255)unsignedInt 0…2550
--- Value (-128 .. +127)signedInt -128…1270
--- Value (0% .. 100%)unsignedInt 0…1000
-- If Measure temperature < Threshold temperaturelistsends comfort
--- Value (0 .. 65535)unsignedInt 0…655350
--- Value (-32768 .. +32767)signedInt -32768…327670
Enable thermal comfort status feedbacklistenable
The season summer/winterlistfollows active functioning type
- Logical value associated with the seasonslist1 = summer / 0 = winter
- Season active after an ETS downloadlistsummer
Maximum temperature [0.1 °C]signedInt 200…400260
Minimum temperature [0.1 °C]signedInt 100…300240
Maximum relative humidity [% RH]unsignedInt 50…9560
Minimum relative humidity [% RH]unsignedInt 10…4540
Maximum specific humidity [% RH]unsignedInt 50…220115
Maximum temperature [0.1 °C]signedInt 200…400220
Minimum temperature [0.1 °C]signedInt 100…300180

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Wall mounting KNX thermostat with humidity S 1.2 1.2 latest$53084DC22026-11-25341 KBDownload

About this file

This is the official ETS product database for the GEWISS GW10795H (GW10795H), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from GEWISS

All GEWISS products