KNX Database

GW15799

GEWISS · Order number GW15799 · Climate control devices › Sonde da incasso

Download .knxprod KNX Temperature sensor flush mounting S 1.2 1.2 · 168 KB

Product

ManufacturerGEWISS
Product nameGW15799
Order numberGW15799
Product textKNX Temperature sensor - Satin white
HardwareSonda di termoregolazione KNX - da incasso
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2020-12-04
Languagesde-DE, en-US, es-ES, it-IT
Catalog entryM-0019_H-10799-0_HP-5306-12-ED9B_CI-GW15799-1
FingerprintED9B
SHA-256e88952f3f0ea016334e60741eb47dccdc0fc318ed5cbc3c5d27e6f80f96f38df
First seen2026-11-25
Markets59 markets

Application program: KNX Temperature sensor flush mounting S 1.2 1.2

Application number$5306
Version1.2
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters248
Group objects213
Group objects (213)
NoNameFunctionSizeDPTFlags
0Setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
0Setpoint input°K value2 Bytes9.2 temperature difference (K)CW
0Setpoint input°F value2 Bytes9.27 temperature (°F)CW
0HVAC mode inputEco/Precom/Comf/Off1 Byte20.102 HVAC modeCW
1HVAC off mode inputEnable/Disable1 Bit1.3 enableCW
1Temporary setpoint forcing inputValue °C2 Bytes9.1 temperature (°C)CW
1Temporary setpoint forcing input°K value2 Bytes9.2 temperature difference (K)CW
1Temporary setpoint forcing input°F value2 Bytes9.27 temperature (°F)CW
2HVAC economy mode inputEnable/Disable1 Bit1.3 enableCW
3HVAC precomfort mode inputEnable/Disable1 Bit1.3 enableCW
4HVAC comfort mode inputEnable/Disable1 Bit1.3 enableCW
5Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCW
6Enable dead zoneEnable/Disable1 Bit1.3 enableCW
7Heating anti-freeze setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
7Heating anti-freeze setpoint input°K value2 Bytes9.2 temperature difference (K)CW
7Heating anti-freeze setpoint input°F value2 Bytes9.27 temperature (°F)CW
8Heating economy setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
8Heating economy setpoint input°K value2 Bytes9.2 temperature difference (K)CW
8Heating economy setpoint input°F value2 Bytes9.27 temperature (°F)CW
9Heating precomfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
9Heating precomfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
9Heating precomfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
10Heating comfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
10Heating comfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
10Heating comfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
11Air-cooling high temp. protection setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
11Air-cooling high temp. protection setpoint input°K value2 Bytes9.2 temperature difference (K)CW
11Air-cooling high temp. protection setpoint input°F value2 Bytes9.27 temperature (°F)CW
12Air-cooling economy setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
12Air-cooling economy setpoint input°K value2 Bytes9.2 temperature difference (K)CW
12Air-cooling economy setpoint input°F value2 Bytes9.27 temperature (°F)CW
13Air-cooling precomfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
13Air-cooling precomfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
13Air-cooling precomfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
14Air-cooling comfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
14Air-cooling comfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
14Air-cooling comfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
15Heating valve switchOn/Off1 Bit1.1 switchCRT
15% command valve heating % Value1 Byte5.1 percentage (0..100%)CRT
15Heating/Air cooling valve switchOn/Off1 Bit1.1 switchCRT
15Heating/air cooling valve % command% Value1 Byte5.1 percentage (0..100%)CRT
16Heating valve status feedbackOn/Off status1 Bit1.1 switchCWTU
16Heating valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
16Heating/air cooling valve status feedbackOn/Off status1 Bit1.1 switchCWTU
16Heating/Air cooling valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
17V1 fan switching heatingOn/Off1 Bit1.1 switchCRT
17% command fancoil speed heating % Value1 Byte5.1 percentage (0..100%)CRT
18V2 fan switching heatingOn/Off1 Bit1.1 switchCRT
19V3 fan switching heatingOn/Off1 Bit1.1 switchCRT
20Heating fan V1 status feedbackOn/Off status1 Bit1.1 switchCWTU
20Heating fancoil speed % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
21Heating fan V2 status feedbackOn/Off status1 Bit1.1 switchCWTU
22Heating fan V3 status feedbackOn/Off status1 Bit1.1 switchCWTU
23Heating 2° stage switchingOn/Off1 Bit1.1 switchCRT
23% command 2° stage heating % Value1 Byte5.1 percentage (0..100%)CRT
24Heating 2° stage feedbackOn/Off status1 Bit1.1 switchCWTU
24Heating 2° stage valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
25Air cooling valve % command% Value1 Byte5.1 percentage (0..100%)CRT
25Air cooling valve switchOn/Off1 Bit1.1 switchCRT
26Air cooling valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
26Air cooling valve status feedbackOn/Off status1 Bit1.1 switchCWTU
27% command fancoil speed air cooling % Value1 Byte5.1 percentage (0..100%)CRT
27V1 fan switching air coolingOn/Off1 Bit1.1 switchCRT
28V2 fan switching air coolingOn/Off1 Bit1.1 switchCRT
29V3 fan switching air coolingOn/Off1 Bit1.1 switchCRT
30Air cooling fancoil speed % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
30Air cooling fan V1 status feedbackOn/Off status1 Bit1.1 switchCWTU
31Air cooling fan V2 status feedbackOn/Off status1 Bit1.1 switchCWTU
32Air cooling fan V3 status feedbackOn/Off status1 Bit1.1 switchCWTU
33% command 2° stage air cooling % Value1 Byte5.1 percentage (0..100%)CRT
33Air cooling 2° stage switchingOn/Off1 Bit1.1 switchCRT
34Air cooling 2° stage valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
34Air cooling 2° stage feedbackOn/Off status1 Bit1.1 switchCWTU
35Fancoil mode inputAutomatic/manual1 Bit1.1 switchCW
36Fan coil mode reportAutomatic/manual1 Bit1.1 switchCRT
37KNX external sensor inputValue °C2 Bytes9.1 temperature (°C)CWTU
37KNX external sensor input°K value2 Bytes9.2 temperature difference (K)CWTU
37KNX external sensor input°F value2 Bytes9.27 temperature (°F)CWTU
37KNX floor sensor inputValue °C2 Bytes9.1 temperature (°C)CWTU
37KNX floor sensor input°K value2 Bytes9.2 temperature difference (K)CWTU
37KNX floor sensor input°F value2 Bytes9.27 temperature (°F)CWTU
38Auxiliary sensor measured temperatureValue °C2 Bytes9.1 temperature (°C)CR
38Auxiliary sensor measured temperature°K value2 Bytes9.2 temperature difference (K)CR
38Auxiliary sensor measured temperature°F value2 Bytes9.27 temperature (°F)CR
38Auxiliary sensor measured temperatureValue °C2 Bytes9.1 temperature (°C)CRT
38Auxiliary sensor measured temperature°K value2 Bytes9.2 temperature difference (K)CRT
38Auxiliary sensor measured temperature°F value2 Bytes9.27 temperature (°F)CRT
39Measured temperatureValue °C2 Bytes9.1 temperature (°C)CR
39Measured temperature°K value2 Bytes9.2 temperature difference (K)CR
39Measured temperature°F value2 Bytes9.27 temperature (°F)CR
39Measured temperatureValue °C2 Bytes9.1 temperature (°C)CRT
39Measured temperature°K value2 Bytes9.2 temperature difference (K)CRT
39Measured temperature°F value2 Bytes9.27 temperature (°F)CRT
40Functioning setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
40Functioning setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
40Functioning setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
40Functioning setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
40Functioning setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
40Functioning setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
40HVAC mode feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCR
40HVAC mode feedbackEco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
41HVAC off mode feedbackEnable/Disable1 Bit1.3 enableCR
41HVAC off mode feedbackEnable/Disable1 Bit1.3 enableCRT
42HVAC economy mode feedbackEnable/Disable1 Bit1.3 enableCR
42HVAC economy mode feedbackEnable/Disable1 Bit1.3 enableCRT
43HVAC precomfort mode feedbackEnable/Disable1 Bit1.3 enableCR
43HVAC precomfort mode feedbackEnable/Disable1 Bit1.3 enableCRT
44HVAC comfort mode feedbackEnable/Disable1 Bit1.3 enableCR
44HVAC comfort mode feedbackEnable/Disable1 Bit1.3 enableCRT
45Functioning type feedbackHeating/Air cooling1 Bit1.100 heating/coolingCRT
45Functioning type feedbackHeating/Air cooling1 Bit1.100 heating/coolingCR
46Heating anti-freeze setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
46Heating anti-freeze setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
46Heating anti-freeze setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
46Heating anti-freeze setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
46Heating anti-freeze setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
46Heating anti-freeze setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
47Heating economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
47Heating economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
47Heating economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
47Heating economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
47Heating economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
47Heating economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
48Heating precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
48Heating precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
48Heating precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
48Heating precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
48Heating precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
48Heating precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
49Heating comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
49Heating comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
49Heating comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
49Heating comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
49Heating comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
49Heating comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
50Air cond. high temp. protection setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
50Air cond. high temp. protection setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
50Air cond. high temp. protection setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
50Air cond. high temp. protection setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
50Air cond. high temp. protection setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
50Air cond. high temp. protection setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
51Air cooling economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
51Air cooling economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
51Air cooling economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
51Air cooling economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
51Air cooling economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
51Air cooling economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
52Air cooling precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
52Air cooling precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
52Air cooling precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
52Air cooling precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
52Air cooling precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
52Air cooling precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
53Air cooling comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
53Air cooling comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
53Air cooling comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
53Air cooling comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
53Air cooling comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
53Air cooling comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
54Current setpoint report°K value2 Bytes9.2 temperature difference (K)CR
54Current setpoint reportValue °C2 Bytes9.1 temperature (°C)CR
54Current setpoint report°F value2 Bytes9.27 temperature (°F)CR
54Current setpoint reportValue °C2 Bytes9.1 temperature (°C)CRT
54Current setpoint report°K value2 Bytes9.2 temperature difference (K)CRT
54Current setpoint report°F value2 Bytes9.27 temperature (°F)CRT
55Feedbacks sending triggerSend feedbacks1 Bit1.17 triggerCW
56KNX sensor sceneExecute/Store1 Byte18.1 scene controlCW
57Input aux 1 - Dimmer status feedbackOn/Off status1 Bit1.1 switchCWTU
57Input aux 1 - Status feedbackOn/Off status1 Bit1.1 switchCWTU
57Input aux 1 - Movement feedbackIncrease/Decrease1 Bit1.8 up/downCW
58Input aux 1 - 14 byte valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
58Input aux 1 - 1 bit value1/0 value1 Bit1.1 switchCRT
58Input aux 1 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
58Input aux 1 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
58Input aux 1 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
58Input aux 1 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
58Input aux 1 - 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
58Input aux 1 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
58Input aux 1 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
58Input aux 1 - 4 byte valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
58Input aux 1 - 4 byte valueSigned value4 Bytes13.1 counter pulses (signed)CRT
58Input aux 1 - SwitchingOn/Off1 Bit1.1 switchCRT
58Input aux 1 - Shutter movementUp/Down1 Bit1.8 up/downCRT
58Input aux 1 - SceneExecute/Store1 Byte18.1 scene controlCRT
58Input aux 1 - Window status feedbackOpen/Closed1 Bit1.2 booleanCR
58Input aux 1 - Window status feedbackOpen/Closed1 Bit1.2 booleanCRT
58Inputs aux 1/2 - SwitchingOn/Off1 Bit1.1 switchCRT
58Inputs aux 1/2 - Shutter movementUp/Down1 Bit1.8 up/downCRT
59Input aux 1 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
59Input aux 1 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
59Input aux 1 - Scene storing triggerStore1 Bit1.17 triggerCW
59Inputs aux 1/2 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
59Inputs aux 1/2 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
60Input aux 2 - Dimmer status feedbackOn/Off status1 Bit1.1 switchCWTU
60Input aux 2 - Status feedbackOn/Off status1 Bit1.1 switchCWTU
60Input aux 2 - Movement feedbackIncrease/Decrease1 Bit1.8 up/downCW
61Input aux 2 - 14 byte valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
61Input aux 2 - 1 bit value1/0 value1 Bit1.1 switchCRT
61Input aux 2 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
61Input aux 2 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
61Input aux 2 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
61Input aux 2 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
61Input aux 2 - 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
61Input aux 2 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
61Input aux 2 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
61Input aux 2 - 4 byte valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
61Input aux 2 - 4 byte valueSigned value4 Bytes13.1 counter pulses (signed)CRT
61Input aux 2 - SwitchingOn/Off1 Bit1.1 switchCRT
61Input aux 2 - Shutter movementUp/Down1 Bit1.8 up/downCRT
61Input aux 2 - SceneExecute/Store1 Byte18.1 scene controlCRT
62Input aux 2 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
62Input aux 2 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
62Input aux 2 - Scene storing triggerStore1 Bit1.17 triggerCW
Parameters (148)
ParameterTypeDefault
ETS downloadlistBB
Input contacts functionlisttwo auxiliary inputs independent
Operation LEDlistenable
Status LED active loadlistenable
Remote control typelistHVAC mode
Commands format for HVAC mode settinglist1 byte
- Reception 1 bit mode con priority > actuallistkeep lower priority objects value
- Reception 1 bit mode con priority < actuallistupdate object value
HVAC mode setpoint modification via buslistdisable
Temporary setpoint forcing via buslistdisable
Setpoint input measure unitlistCelsius degrees (°C)
Setpoint and temporary setpoint forcing objects measure unitlistCelsius degrees (°C)
- Imposta tipo di funzionamentolistenable
Imposta parametri da remotolistenable
Imposta tipo di funzionamentolistby local command or from bus
Control logic Heating/Air coolinglistdifferent (4 pipe)
Heating/Air cooling control algorithmlisttwo points ON-OFF
Heating/air cooling valve status feedbacklistenable
- Commands repetition period with disabled feedbacklist5 minutes
Ripeti comando su cambiamento stato attuatore RISClistenable
Fancoil valves managementlisttwo points ON-OFF
- Regulation differential valve heat/air-cond (tenth of °C)unsignedInt 1…202
- Heating/air cooling valve status feedbacklistenable
-- Commands repetition period with disabled feedbacklist5 minutes
Fancoil speed modification via buslistdisable
Fancoil mode (automatic/manual) feedbacklistdisable
Heating control algorithmlisttwo points ON-OFF
Air cooling control algorithmlisttwo points ON-OFF
Regulation differential (tenth of °C)unsignedInt 1…202
Select heating systemlistfloor heating
- Proportional bandlist2.0 °C
- Integration timelist60 minutes
- Cycle timelist30 minutes
- Min. % variation for continuous command sendinglist5%
Fancoil speed numberlist3
- Regulation differential speed 1 (tenth of °C)unsignedInt 0…202
- Speed 1 inertia time (seconds)unsignedInt 0…100
Fancoil speed status feedbacklistenable
- Command repetition time fancoil speedlist5 minutes
- Regulation differential speed 2 (tenth of °C)unsignedInt 1…202
- Speed 2 inertia time (seconds)unsignedInt 0…100
- Regulation differential speed 3 (tenth of °C)unsignedInt 1…202
- Speed 3 inertia time (seconds)unsignedInt 0…100
Heating 2° stagelistdisabled
- Operation limit 2° stage (tenths of °C)unsignedInt 10…10010
- Regulation differential 2° stage (tenth of °C)unsignedInt 1…202
Heating 2° stage feedbacklistenable
- Command repetition time 2° stage without feedbacklist5 minutes
Ripeti comando su cambiamento stato 2° stadio RISClistenable
Heating valve status feedbacklistenable
- Regulation differential valve (tenth of °C)unsignedInt 1…202
- Heating valve status feedbacklistenable
Select air cooling systemlistceiling cooling
- Proportional bandlist5.0 °C
- Integration timelist240 minutes
air cooling 2° stagelistdisabled
Air cooling 2° stage feedbacklistenable
Ripeti comando su cambiamento stato 2° stadio CONDlistenable
Air cooling valve status feedbacklistenable
Ripeti comando su cambiamento stato attuatore CONDlistenable
- Air cooling valve status feedbacklistenable
Comfort setpoint (tenths of °C)signedInt 50…400200
Precomfort setpoint (tenths of °C)signedInt 50…400180
Economy setpoint (tenths of °C)signedInt 50…400160
Antifreeze setpoint (tenths of °C)signedInt 20…7050
Comfort setpoint (tenths of °C)signedInt 50…400240
Precomfort setpoint (tenths of °C)signedInt 50…400260
Economy setpoint (tenths of °C)signedInt 50…400280
High temperature protection setpoint (tenths of °C)signedInt 300…400350
modify all the setpoints of the same functioning typelistno
modify contemporary the setpoint of the other functioning typelistno
Functioning setpoint (tenths of °C)signedInt 50…400200
Antifreeze setpoint for window contact (tenths of °C)signedInt 20…7050
Functioning setpoint (tenths of °C)signedInt 50…400240
High temperature protection setpoint for window contact (tenths of °C)signedInt 300…400350
Internal sensor correction factor (tenths of °C)signedInt -20…200
KNX external sensorlistdisabled
- Measure unit KNX external sensorlistCelsius degrees (°C)
- KNX ext. sensor incidence in measured temp. calculationlist10%
- KNX external sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
- Behaviour at KNX external sensor signal absencelistuse last value received
- KNX floor sensor measure unitlistCelsius degrees (°C)
- Threshold temperature temperature alarm (tenth of °C)unsignedInt 150…1000500
- Temperature alarm hysteresis (tenth of °C)unsignedInt 10…10030
- KNX floor sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
- Behaviour at KNX floor sensor signal absencelistactivate temperature alarm
Auxiliary external sensorlistenables temperature sensor
- Correction factor auxiliary sensor (tenths of °C)signedInt -20…200
- Auxiliary ext. sensor incidence in measured temp. calculationlist10%
- Behaviour at auxiliary external sensor signal absencelistuse last value received
Auxiliary sensor measured temperaturelistdo not send
-- Measure unit auxiliary sensorlistCelsius degrees (°C)
-- Auxiliary sensor temperature min. variation for sending value [± 0.1 °C]unsignedInt 1…105
-- Auxiliary sensor temperature sending period [minutes]unsignedInt 1…2555
- Behaviour at auxiliary floor sensor signal absencelistactivate temperature alarm
- Temperature measured by auxiliary floor sensorlistdo not send
Measured temperaturelistdo not send
- Measure unitlistCelsius degrees (°C)
- Min. % variation for sending value [± 0.1 °C]unsignedInt 1…105
- Temperature sending period [minutes]unsignedInt 1…2555
HVAC mode feedbacklistdisabled
- 1 bit HVAC modeliston demand only
- 1 byte HVAC modeliston demand only
Functioning setpoint feedbacklistdisabled
Functioning type feedbacklistdisabled
Current setpoint reportlistdisabled
HVAC mode setpoint feedbacklistdisabled
Feedbacks sending trigger objectlistdisable
Scenes functionlistdisable
Scene number 1listunassigned
Scene number 2listunassigned
Scene number 3listunassigned
Scene number 4listunassigned
Scene number 5listunassigned
Scene number 6listunassigned
Scene number 7listunassigned
Scene number 8listunassigned
Parameters to memorize while storinglistHVAC mode only
Parameters to memorize while storinglistsetpoint only
Matched functionlistnone
Sending object formatlist1 bit
- Sending on contact closing detectionlist1
- Sending on contact opening detectionlistno effect
-- Status feedback objectlistdisabled
- Sending on contact closing detectionlistactivate on (down) forcing
- Sending on contact closing detectionlistvalue sending
-- Value (0 .. 255)unsignedInt 0…2550
-- Value (-128 .. +127)signedInt -128…1270
-- Value (0% .. 100%)unsignedInt 0…1000
- Sending on contact closing detectionlistcomfort
-- Value (0 .. 65535)unsignedInt 0…655350
-- Value (-32768 .. +32767)signedInt -32768…327670
-- Value (0 .. 4294967295)unsignedInt 0…42949672950
-- Value (-2147483648 .. +2147483647)signedInt -2147483648…21474836470
-- Value (characters ISO 8859-1)text
- Sending on short operation detectionlist1
- Sending on long operation detectionlistno effect
- Sending on short operation detectionlistvalue sending
- Sending on short operation detectionlistcomfort
Dimmer status feedback objectlistdisable
- Brightness dimming commands with dimmer onlistbrightness increase and decrease
Increase/decrease steplist12.5%
Cyclical sending period [x 0.1s]unsignedInt 3…505
Scene number (0 .. 63)unsignedInt 0…630
Scene storing by long operationlistenabled
Window statuslistclosed if contact is open
Send window contact status feedbacklistdisabled
Matched functionlistdimming with STOP telegram

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX Temperature sensor flush mounting S 1.2 1.2 latest$5306ED9B2026-11-25168 KBDownload

About this file

This is the official ETS product database for the GEWISS GW15799 (GW15799), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from GEWISS

All GEWISS products