KNX Database

GW15794H

GEWISS · Order number GW15794H · Climate control devices › Cronotermostati

Download .knxprod KNX Chrono/Programmer with humidity S 1.1 1.1 · 554 KB

Product

ManufacturerGEWISS
Product nameGW15794H
Order numberGW15794H
Product textKNX Chrono/Programmer with humidity - Satin white
HardwareCrono/Programmatore con umidità KNX - da incasso
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationCertified · 2020-12-04
Languagesde-DE, en-US, es-ES, it-IT
Catalog entryM-0019_H-10794H-0_HP-5307-11-384E_CI-GW15794H-0
Fingerprint384E
SHA-2565c342da9f1613b6c85a7be4666a96b73d84fdbc3c31b28211c0a2c69b75a0df2
First seen2026-11-25
Markets59 markets

Application program: KNX Chrono/Programmer with humidity S 1.1 1.1

Application number$5307
Version1.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version4.0
Parameters3556
Group objects1051
Group objects (1051)
NoNameFunctionSizeDPTFlags
0Day/Hour inputUpdate day/hour3 Bytes10.1 time of dayCW
1Day/Hour sendingSend day/hour3 Bytes10.1 time of dayCRT
2Daylight saving time input1= daylight saving/0= standard1 Bit1.1 switchCW
3Enable master functionEnable/Disable1 Bit1.3 enableCW
4HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCW
5Setpoint temporary forcing regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
6HVAC off mode inputEnable/Disable1 Bit1.3 enableCW
7HVAC economy mode inputEnable/Disable1 Bit1.3 enableCW
8HVAC precomfort mode inputEnable/Disable1 Bit1.3 enableCW
9HVAC comfort mode inputEnable/Disable1 Bit1.3 enableCW
10HVAC auto mode inputEnable/Disable1 Bit1.3 enableCW
11Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCW
12Enable dead zoneEnable/Disable1 Bit1.3 enableCW
13Heating anti-freeze setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
13Heating anti-freeze setpoint input°K value2 Bytes9.2 temperature difference (K)CW
13Heating anti-freeze setpoint input°F value2 Bytes9.27 temperature (°F)CW
13Heating anti-freeze setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
14Heating economy setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
14Heating economy setpoint input°K value2 Bytes9.2 temperature difference (K)CW
14Heating economy setpoint input°F value2 Bytes9.27 temperature (°F)CW
14Heating economy setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
15Heating precomfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
15Heating precomfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
15Heating precomfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
15Heating precomfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
16Heating comfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
16Heating comfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
16Heating comfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
16Heating comfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
17Air-cooling high temp. protection setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
17Air-cooling high temp. protection setpoint input°K value2 Bytes9.2 temperature difference (K)CW
17Air-cooling high temp. protection setpoint input°F value2 Bytes9.27 temperature (°F)CW
17Air-cooling high temp. protec. setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
18Air-cooling economy setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
18Air-cooling economy setpoint input°K value2 Bytes9.2 temperature difference (K)CW
18Air-cooling economy setpoint input°F value2 Bytes9.27 temperature (°F)CW
18Air-cooling economy setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
19Air-cooling precomfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
19Air-cooling precomfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
19Air-cooling precomfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
19Air-cooling precomfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
20Air-cooling comfort setpoint inputValue °C2 Bytes9.1 temperature (°C)CW
20Air-cooling comfort setpoint input°K value2 Bytes9.2 temperature difference (K)CW
20Air-cooling comfort setpoint input°F value2 Bytes9.27 temperature (°F)CW
20Air-cooling comfort setpoint regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
21Heating valve switchOn/Off1 Bit1.1 switchCRT
21% command valve heating % Value1 Byte5.1 percentage (0..100%)CRT
21Heating/Air cooling valve switchOn/Off1 Bit1.1 switchCRT
21Heating/air cooling valve % command% Value1 Byte5.1 percentage (0..100%)CRT
22Heating valve status feedbackOn/Off status1 Bit1.1 switchCWTU
22Heating valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
22Heating/air cooling valve status feedbackOn/Off status1 Bit1.1 switchCWTU
22Heating/Air cooling valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
23V1 fan switching heatingOn/Off1 Bit1.1 switchCRT
23% command fancoil speed heating % Value1 Byte5.1 percentage (0..100%)CRT
24V2 fan switching heatingOn/Off1 Bit1.1 switchCRT
25V3 fan switching heatingOn/Off1 Bit1.1 switchCRT
26Heating fan V1 status feedbackOn/Off status1 Bit1.1 switchCWTU
26Heating fancoil speed % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
27Heating fan V2 status feedbackOn/Off status1 Bit1.1 switchCWTU
28Heating fan V3 status feedbackOn/Off status1 Bit1.1 switchCWTU
29Heating 2° stage switchingOn/Off1 Bit1.1 switchCRT
29% command 2° stage heating % Value1 Byte5.1 percentage (0..100%)CRT
30Heating 2° stage feedbackOn/Off status1 Bit1.1 switchCWTU
30Heating 2° stage valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
31Air cooling valve % command% Value1 Byte5.1 percentage (0..100%)CRT
31Air cooling valve switchOn/Off1 Bit1.1 switchCRT
32Air cooling valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
32Air cooling valve status feedbackOn/Off status1 Bit1.1 switchCWTU
33% command fancoil speed air cooling % Value1 Byte5.1 percentage (0..100%)CRT
33V1 fan switching air coolingOn/Off1 Bit1.1 switchCRT
34V2 fan switching air coolingOn/Off1 Bit1.1 switchCRT
35V3 fan switching air coolingOn/Off1 Bit1.1 switchCRT
36Air cooling fancoil speed % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
36Air cooling fan V1 status feedbackOn/Off status1 Bit1.1 switchCWTU
37Air cooling fan V2 status feedbackOn/Off status1 Bit1.1 switchCWTU
38Air cooling fan V3 status feedbackOn/Off status1 Bit1.1 switchCWTU
39% command 2° stage air cooling % Value1 Byte5.1 percentage (0..100%)CRT
39Air cooling 2° stage switchingOn/Off1 Bit1.1 switchCRT
40Air cooling 2° stage valve % feedback% Value1 Byte5.1 percentage (0..100%)CWTU
40Air cooling 2° stage feedbackOn/Off status1 Bit1.1 switchCWTU
41Fancoil mode inputAutomatic/manual1 Bit1.1 switchCW
42Fan coil mode feedbackAutomatic/manual1 Bit1.1 switchCRT
43KNX external sensor inputValue °C2 Bytes9.1 temperature (°C)CWTU
43KNX external sensor input°K value2 Bytes9.2 temperature difference (K)CWTU
43KNX external sensor input°F value2 Bytes9.27 temperature (°F)CWTU
43KNX floor sensor inputValue °C2 Bytes9.1 temperature (°C)CWTU
43KNX floor sensor input°K value2 Bytes9.2 temperature difference (K)CWTU
43KNX floor sensor input°F value2 Bytes9.27 temperature (°F)CWTU
44Auxiliary sensor measured temperatureValue °C2 Bytes9.1 temperature (°C)CR
44Auxiliary sensor measured temperature°K value2 Bytes9.2 temperature difference (K)CR
44Auxiliary sensor measured temperature°F value2 Bytes9.27 temperature (°F)CR
44Auxiliary sensor measured temperatureValue °C2 Bytes9.1 temperature (°C)CRT
44Auxiliary sensor measured temperature°K value2 Bytes9.2 temperature difference (K)CRT
44Auxiliary sensor measured temperature°F value2 Bytes9.27 temperature (°F)CRT
45Measured temperatureValue °C2 Bytes9.1 temperature (°C)CR
45Measured temperature°K value2 Bytes9.2 temperature difference (K)CR
45Measured temperature°F value2 Bytes9.27 temperature (°F)CR
45Measured temperatureValue °C2 Bytes9.1 temperature (°C)CRT
45Measured temperature°K value2 Bytes9.2 temperature difference (K)CRT
45Measured temperature°F value2 Bytes9.27 temperature (°F)CRT
46HVAC mode feedbackAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCR
46HVAC mode feedbackAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
47HVAC off mode feedbackEnable/Disable1 Bit1.3 enableCR
47HVAC off mode feedbackEnable/Disable1 Bit1.3 enableCRT
48HVAC economy mode feedbackEnable/Disable1 Bit1.3 enableCR
48HVAC economy mode feedbackEnable/Disable1 Bit1.3 enableCRT
49HVAC precomfort mode feedbackEnable/Disable1 Bit1.3 enableCR
49HVAC precomfort mode feedbackEnable/Disable1 Bit1.3 enableCRT
50HVAC comfort mode feedbackEnable/Disable1 Bit1.3 enableCR
50HVAC comfort mode feedbackEnable/Disable1 Bit1.3 enableCRT
51HVAC auto mode feedbackEnable/Disable1 Bit1.3 enableCR
51HVAC auto mode feedbackEnable/Disable1 Bit1.3 enableCRT
52Functioning type feedbackHeating/Air cooling1 Bit1.100 heating/coolingCRT
52Functioning type feedbackHeating/Air cooling1 Bit1.100 heating/coolingCR
53Heating anti-freeze setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
53Heating anti-freeze setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
53Heating anti-freeze setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
53Heating anti-freeze setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
53Heating anti-freeze setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
53Heating anti-freeze setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
54Heating economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
54Heating economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
54Heating economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
54Heating economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
54Heating economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
54Heating economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
55Heating precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
55Heating precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
55Heating precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
55Heating precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
55Heating precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
55Heating precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
56Heating comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
56Heating comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
56Heating comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
56Heating comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
56Heating comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
56Heating comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
57Air cond. high temp. protection setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
57Air cond. high temp. protection setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
57Air cond. high temp. protection setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
57Air cond. high temp. protection setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
57Air cond. high temp. protection setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
57Air cond. high temp. protection setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
58Air cooling economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
58Air cooling economy setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
58Air cooling economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
58Air cooling economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
58Air cooling economy setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
58Air cooling economy setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
59Air cooling precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
59Air cooling precomfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
59Air cooling precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
59Air cooling precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
59Air cooling precomfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
59Air cooling precomfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
60Air cooling comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
60Air cooling comfort setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
60Air cooling comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
60Air cooling comfort setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
60Air cooling comfort setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
60Air cooling comfort setpoint feedback°F value2 Bytes9.7 humidity (%)CR
61Current setpoint feedback°K value2 Bytes9.2 temperature difference (K)CR
61Current setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CR
61Current setpoint feedback°F value2 Bytes9.27 temperature (°F)CR
61Current setpoint feedbackValue °C2 Bytes9.1 temperature (°C)CRT
61Current setpoint feedback°K value2 Bytes9.2 temperature difference (K)CRT
61Current setpoint feedback°F value2 Bytes9.27 temperature (°F)CRT
62Chronothermostat functioning feedbackMaster/Autonomous1 Bit1.1 switchCR
62Chronothermostat functioning feedbackMaster/Autonomous1 Bit1.1 switchCRT
63Feedbacks sending triggerSend feedbacks1 Bit1.17 triggerCW
64Chronothermostat sceneExecute/Store1 Byte18.1 scene controlCW
65Setpoint sending to slavesValue °C2 Bytes9.1 temperature (°C)CRT
65Setpoint sending to slaves°K value2 Bytes9.2 temperature difference (K)CRT
65Setpoint sending to slaves°F value2 Bytes9.27 temperature (°F)CRT
65Sending HVAC mode to slavesEco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
66Functioning type sending to slavesHeating/Air cooling1 Bit1.100 heating/coolingCRT
67Sending command to slaves triggerSlave updating1 Bit1.17 triggerCW
68Input aux 1 - Dimmer status feedbackOn/Off status1 Bit1.1 switchCWTU
68Input aux 1 - Status feedbackOn/Off status1 Bit1.1 switchCWTU
68Input aux 1 - Movement feedbackIncrease/Decrease1 Bit1.8 up/downCW
69Input aux 1 - 14 byte valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
69Input aux 1 - 1 bit value1/0 value1 Bit1.1 switchCRT
69Input aux 1 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
69Input aux 1 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
69Input aux 1 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
69Input aux 1 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
69Input aux 1 - 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
69Input aux 1 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
69Input aux 1 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
69Input aux 1 - 4 byte valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
69Input aux 1 - 4 byte valueSigned value4 Bytes13.1 counter pulses (signed)CRT
69Input aux 1 - SwitchingOn/Off1 Bit1.1 switchCRT
69Input aux 1 - Shutter movementUp/Down1 Bit1.8 up/downCRT
69Input aux 1 - SceneExecute/Store1 Byte20.102 HVAC modeCRT
69Input aux 1 - Window status feedbackOpen/Closed1 Bit1.19 window/doorCRT
69Input aux 1 - Window status feedbackOpen/Closed1 Bit1.19 window/doorCR
69Inputs aux 1/2 - SwitchingOn/Off1 Bit1.1 switchCRT
69Inputs aux 1/2 - Shutter movementUp/Down1 Bit1.8 up/downCRT
70Input aux 1 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
70Input aux 1 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
70Input aux 1 - Scene storing triggerStore1 Bit1.17 triggerCW
70Inputs aux 1/2 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
70Inputs aux 1/2 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
71Input aux 2 - Dimmer status feedbackOn/Off status1 Bit1.1 switchCWTU
71Input aux 2 - Status feedbackOn/Off status1 Bit1.1 switchCWTU
71Input aux 2 - Movement feedbackIncrease/Decrease1 Bit1.8 up/downCW
72Input aux 2 - 14 byte valueCharacters ISO 8859-114 Bytes16.1 Character String (ISO 8859-1)CRT
72Input aux 2 - 1 bit value1/0 value1 Bit1.1 switchCRT
72Input aux 2 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
72Input aux 2 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
72Input aux 2 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
72Input aux 2 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
72Input aux 2 - 1 byte valueHVAC mode1 Byte20.102 HVAC modeCRT
72Input aux 2 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
72Input aux 2 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
72Input aux 2 - 4 byte valueUnsigned value4 Bytes12.1 counter pulses (unsigned)CRT
72Input aux 2 - 4 byte valueSigned value4 Bytes13.1 counter pulses (signed)CRT
72Input aux 2 - SwitchingOn/Off1 Bit1.1 switchCRT
72Input aux 2 - Shutter movementUp/Down1 Bit1.8 up/downCRT
72Input aux 2 - SceneExecute/Store1 Byte20.102 HVAC modeCRT
73Input aux 2 - Brightness controlIncrease/Decrease4 Bit3.7 dimming controlCRT
73Input aux 2 - Shutter stop/Louvres controlStop/Step1 Bit1.7 stepCRT
73Input aux 2 - Scene storing triggerStore1 Bit1.17 triggerCW
74Output aux - StatusOn/Off1 Bit1.1 switchCR
74Output aux - StatusOn/Off1 Bit1.1 switchCRT
75Output aux - SwitchingOn/Off1 Bit1.1 switchCW
76Output aux - Timed switchingStart/Stop1 Bit1.10 start/stopCW
77Output aux - Priority commandOn/Off forced positioning2 Bit2.1 switch controlCW
78Output aux - SceneExecute/Store1 Byte18.1 scene controlCW
79Time profile 1 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
79Time profile 1 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
79Time profile 1 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
79Time profile 1 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
79Time profile 1 - 1 bit valueOn/Off1 Bit1.1 switchCRT
79Time profile 1 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
79Time profile 1 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
79Time profile 1 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
79Time profile 1 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
79Time profile 1 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
79Time profile 1 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
79Time profile 1 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
79Time profile 1 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
79Time profile 1 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
80Time profile 1 - Activate profileSwitching On/Off1 Bit1.1 switchCW
81Time profile 1 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
82Time profile 1 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
83Time profile 1 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
84Time profile 1 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
85Time profile 1 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
86Time profile 2 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
86Time profile 2 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
86Time profile 2 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
86Time profile 2 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
86Time profile 2 - 1 bit valueOn/Off1 Bit1.1 switchCRT
86Time profile 2 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
86Time profile 2 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
86Time profile 2 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
86Time profile 2 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
86Time profile 2 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
86Time profile 2 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
86Time profile 2 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
86Time profile 2 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
86Time profile 2 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
87Time profile 2 - Activate profileSwitching On/Off1 Bit1.1 switchCW
88Time profile 2 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
89Time profile 2 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
90Time profile 2 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
91Time profile 2 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
92Time profile 2 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
93Time profile 3 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
93Time profile 3 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
93Time profile 3 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
93Time profile 3 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
93Time profile 3 - 1 bit valueOn/Off1 Bit1.1 switchCRT
93Time profile 3 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
93Time profile 3 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
93Time profile 3 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
93Time profile 3 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
93Time profile 3 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
93Time profile 3 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
93Time profile 3 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
93Time profile 3 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
93Time profile 3 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
93Time profile 1 - 1 bit valueOn/Off1 Bit1.1 switchCRT
93Time profile 1 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
93Time profile 1 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
93Time profile 1 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
93Time profile 1 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
93Time profile 1 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
93Time profile 1 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
93Time profile 1 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
93Time profile 1 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
93Time profile 1 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
93Time profile 1 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
93Time profile 1 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
93Time profile 1 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
93Time profile 1 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
94Time profile 3 - Activate profileSwitching On/Off1 Bit1.1 switchCW
94Time profile 1 - Activate profileSwitching On/Off1 Bit1.1 switchCW
95Time profile 3 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
95Time profile 1 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
96Time profile 3 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
96Time profile 1 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
97Time profile 3 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
97Time profile 1 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
98Time profile 3 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
98Time profile 1 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
99Time profile 3 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
99Time profile 1 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
100Time profile 4 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
100Time profile 4 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
100Time profile 4 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
100Time profile 4 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
100Time profile 4 - 1 bit valueOn/Off1 Bit1.1 switchCRT
100Time profile 4 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
100Time profile 4 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
100Time profile 4 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
100Time profile 4 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
100Time profile 4 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
100Time profile 4 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
100Time profile 4 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
100Time profile 4 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
100Time profile 4 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
100Time profile 2 - 1 bit valueOn/Off1 Bit1.1 switchCRT
100Time profile 2 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
100Time profile 2 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
100Time profile 2 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
100Time profile 2 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
100Time profile 2 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
100Time profile 2 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
100Time profile 2 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
100Time profile 2 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
100Time profile 2 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
100Time profile 2 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
100Time profile 2 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
100Time profile 2 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
100Time profile 2 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
101Time profile 4 - Activate profileSwitching On/Off1 Bit1.1 switchCW
101Time profile 2 - Activate profileSwitching On/Off1 Bit1.1 switchCW
102Time profile 4 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
102Time profile 2 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
103Time profile 4 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
103Time profile 2 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
104Time profile 4 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
104Time profile 2 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
105Time profile 4 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
105Time profile 2 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
106Time profile 4 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
106Time profile 2 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
107Time profile 5 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
107Time profile 5 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
107Time profile 5 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
107Time profile 5 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
107Time profile 5 - 1 bit valueOn/Off1 Bit1.1 switchCRT
107Time profile 5 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
107Time profile 5 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
107Time profile 5 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
107Time profile 5 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
107Time profile 5 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
107Time profile 5 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
107Time profile 5 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
107Time profile 5 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
107Time profile 5 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
107Time profile 3 - 1 bit valueOn/Off1 Bit1.1 switchCRT
107Time profile 3 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
107Time profile 3 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
107Time profile 3 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
107Time profile 3 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
107Time profile 3 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
107Time profile 3 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
107Time profile 3 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
107Time profile 3 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
107Time profile 3 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
107Time profile 3 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
107Time profile 3 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
107Time profile 3 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
107Time profile 3 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
108Time profile 5 - Activate profileSwitching On/Off1 Bit1.1 switchCW
108Time profile 3 - Activate profileSwitching On/Off1 Bit1.1 switchCW
109Time profile 5 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
109Time profile 3 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
110Time profile 5 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
110Time profile 3 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
111Time profile 5 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
111Time profile 3 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
112Time profile 5 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
112Time profile 3 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
113Time profile 5 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
113Time profile 3 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
114Time profile 6 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
114Time profile 6 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
114Time profile 6 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
114Time profile 6 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
114Time profile 6 - 1 bit valueOn/Off1 Bit1.1 switchCRT
114Time profile 6 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
114Time profile 6 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
114Time profile 6 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
114Time profile 6 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
114Time profile 6 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
114Time profile 6 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
114Time profile 6 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
114Time profile 6 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
114Time profile 6 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
114Time profile 4 - 1 bit valueOn/Off1 Bit1.1 switchCRT
114Time profile 4 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
114Time profile 4 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
114Time profile 4 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
114Time profile 4 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
114Time profile 4 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
114Time profile 4 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
114Time profile 4 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
114Time profile 4 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
114Time profile 4 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
114Time profile 4 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
114Time profile 4 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
114Time profile 4 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
114Time profile 4 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
115Time profile 6 - Activate profileSwitching On/Off1 Bit1.1 switchCW
115Time profile 4 - Activate profileSwitching On/Off1 Bit1.1 switchCW
116Time profile 6 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
116Time profile 4 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
117Time profile 6 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
117Time profile 4 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
118Time profile 6 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
118Time profile 4 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
119Time profile 6 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
119Time profile 4 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
120Time profile 6 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
120Time profile 4 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
121Time profile 7 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
121Time profile 7 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
121Time profile 7 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
121Time profile 7 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
121Time profile 7 - 1 bit valueOn/Off1 Bit1.1 switchCRT
121Time profile 7 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
121Time profile 7 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
121Time profile 7 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
121Time profile 7 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
121Time profile 7 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
121Time profile 7 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
121Time profile 7 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
121Time profile 7 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
121Time profile 7 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
121Time profile 5 - 1 bit valueOn/Off1 Bit1.1 switchCRT
121Time profile 5 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
121Time profile 5 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
121Time profile 5 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
121Time profile 5 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
121Time profile 5 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
121Time profile 5 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
121Time profile 5 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
121Time profile 5 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
121Time profile 5 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
121Time profile 5 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
121Time profile 5 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
121Time profile 5 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
121Time profile 5 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
122Time profile 7 - Activate profileSwitching On/Off1 Bit1.1 switchCW
122Time profile 5 - Activate profileSwitching On/Off1 Bit1.1 switchCW
123Time profile 7 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
123Time profile 5 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
124Time profile 7 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
124Time profile 5 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
125Time profile 7 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
125Time profile 5 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
126Time profile 7 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
126Time profile 5 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
127Time profile 7 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
127Time profile 5 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
128Time profile 8 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
128Time profile 8 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
128Time profile 8 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
128Time profile 8 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
128Time profile 8 - 1 bit valueOn/Off1 Bit1.1 switchCRT
128Time profile 8 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
128Time profile 8 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
128Time profile 8 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
128Time profile 8 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
128Time profile 8 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
128Time profile 8 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
128Time profile 8 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
128Time profile 8 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
128Time profile 8 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
128Time profile 6 - 1 bit valueOn/Off1 Bit1.1 switchCRT
128Time profile 6 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
128Time profile 6 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
128Time profile 6 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
128Time profile 6 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
128Time profile 6 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
128Time profile 6 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
128Time profile 6 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
128Time profile 6 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
128Time profile 6 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
128Time profile 6 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
128Time profile 6 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
128Time profile 6 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
128Time profile 6 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
129Time profile 8 - Activate profileSwitching On/Off1 Bit1.1 switchCW
129Time profile 6 - Activate profileSwitching On/Off1 Bit1.1 switchCW
130Time profile 8 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
130Time profile 6 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
131Time profile 8 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
131Time profile 6 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
132Time profile 8 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
132Time profile 6 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
133Time profile 8 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
133Time profile 6 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
134Time profile 8 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
134Time profile 6 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
135Time profile 9 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
135Time profile 9 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
135Time profile 9 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
135Time profile 9 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
135Time profile 9 - 1 bit valueOn/Off1 Bit1.1 switchCRT
135Time profile 9 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
135Time profile 9 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
135Time profile 9 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
135Time profile 9 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
135Time profile 9 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
135Time profile 9 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
135Time profile 9 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
135Time profile 9 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
135Time profile 9 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
135Time profile 7 - 1 bit valueOn/Off1 Bit1.1 switchCRT
135Time profile 7 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
135Time profile 7 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
135Time profile 7 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
135Time profile 7 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
135Time profile 7 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
135Time profile 7 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
135Time profile 7 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
135Time profile 7 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
135Time profile 7 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
135Time profile 7 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
135Time profile 7 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
135Time profile 7 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
135Time profile 7 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
136Time profile 9 - Activate profileSwitching On/Off1 Bit1.1 switchCW
136Time profile 7 - Activate profileSwitching On/Off1 Bit1.1 switchCW
137Time profile 9 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
137Time profile 7 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
138Time profile 9 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
138Time profile 7 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
139Time profile 9 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
139Time profile 7 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
140Time profile 9 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
140Time profile 7 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
141Time profile 9 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
141Time profile 7 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
142Time profile 10 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
142Time profile 10 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
142Time profile 10 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
142Time profile 10 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
142Time profile 1 - Temperature valueOn/Off1 Bit1.1 switchCRT
142Time profile 1 - Temperature valueUp/Down1 Bit1.8 up/downCRT
142Time profile 1 - Temperature valueTrue/False1 Bit1.2 booleanCRT
142Time profile 10 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
142Time profile 10 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
142Time profile 10 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
142Time profile 10 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
142Time profile 10 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
142Time profile 10 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
142Time profile 10 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
142Time profile 8 - 1 bit valueOn/Off1 Bit1.1 switchCRT
142Time profile 8 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
142Time profile 8 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
142Time profile 8 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
142Time profile 8 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
142Time profile 8 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
142Time profile 8 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
142Time profile 8 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
142Time profile 8 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
142Time profile 8 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
142Time profile 8 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
142Time profile 8 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
142Time profile 8 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
142Time profile 8 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
143Time profile 10 - Activate profileSwitching On/Off1 Bit1.1 switchCW
143Time profile 8 - Activate profileSwitching On/Off1 Bit1.1 switchCW
144Time profile 10 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
144Time profile 8 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
145Time profile 10 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
145Time profile 8 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
146Time profile 10 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
146Time profile 8 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
147Time profile 10 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
147Time profile 8 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
148Time profile 10 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
148Time profile 8 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
149Time profile 11 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
149Time profile 11 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
149Time profile 11 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
149Time profile 11 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
149Time profile 11 - 1 bit valueOn/Off1 Bit1.1 switchCRT
149Time profile 11 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
149Time profile 11 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
149Time profile 11 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
149Time profile 11 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
149Time profile 11 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
149Time profile 11 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
149Time profile 11 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
149Time profile 11 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
149Time profile 11 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
149Time profile 9 - 1 bit valueOn/Off1 Bit1.1 switchCRT
149Time profile 9 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
149Time profile 9 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
149Time profile 9 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
149Time profile 9 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
149Time profile 9 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
149Time profile 9 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
149Time profile 9 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
149Time profile 9 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
149Time profile 9 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
149Time profile 9 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
149Time profile 9 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
149Time profile 9 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
149Time profile 9 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
150Time profile 11 - Activate profileSwitching On/Off1 Bit1.1 switchCW
150Time profile 9 - Activate profileSwitching On/Off1 Bit1.1 switchCW
151Time profile 11 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
151Time profile 9 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
152Time profile 11 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
152Time profile 9 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
153Time profile 11 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
153Time profile 9 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
154Time profile 11 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
154Time profile 9 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
155Time profile 11 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
155Time profile 9 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
156Time profile 12 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
156Time profile 12 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
156Time profile 12 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
156Time profile 12 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
156Time profile 12 - 1 bit valueOn/Off1 Bit1.1 switchCRT
156Time profile 12 - 1 bit valueUp/Down1 Bit1.8 up/downCRT
156Time profile 12 - 1 bit valueTrue/False1 Bit1.2 booleanCRT
156Time profile 12 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
156Time profile 12 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
156Time profile 12 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
156Time profile 12 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
156Time profile 12 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
156Time profile 12 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
156Time profile 12 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
156Time profile 1 - Temperature valueOn/Off1 Bit1.1 switchCRT
156Time profile 1 - Temperature valueUp/Down1 Bit1.8 up/downCRT
156Time profile 1 - Temperature valueTrue/False1 Bit1.2 booleanCRT
156Time profile 10 - 2 bit valueOn/Off forced positioning2 Bit2.1 switch controlCRT
156Time profile 10 - 1 byte valueUnsigned value1 Byte5.10 counter pulses (0..255)CRT
156Time profile 10 - 1 byte valueSigned value1 Byte6.10 counter pulses (-128..127)CRT
156Time profile 10 - 1 byte value% Value1 Byte5.1 percentage (0..100%)CRT
156Time profile 10 - 1 byte valueAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCRT
156Time profile 10 - 1 byte valueExecute/Store1 Byte20.102 HVAC modeCRT
156Time profile 10 - 2 byte valueUnsigned value2 Bytes7.1 pulsesCRT
156Time profile 10 - 2 byte valueSigned value2 Bytes8.1 pulses differenceCRT
156Time profile 10 - Temperature valueValue °C2 Bytes9.1 temperature (°C)CRT
156Time profile 10 - Temperature value°K value2 Bytes9.2 temperature difference (K)CRT
156Time profile 10 - Temperature value°F value2 Bytes9.27 temperature (°F)CRT
157Time profile 12 - Activate profileSwitching On/Off1 Bit1.1 switchCW
157Time profile 10 - Activate profileSwitching On/Off1 Bit1.1 switchCW
158Time profile 12 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
158Time profile 10 - Activation statusActivates/Deactivated1 Bit1.1 switchCRT
159Time profile 12 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
159Time profile 10 - Functioning type inputHeating/Air cooling1 Bit1.100 heating/coolingCWTU
160Time profile 12 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
160Time profile 10 - HVAC mode inputAuto/Eco/Precom/Comf/Off1 Byte20.102 HVAC modeCWTU
161Time profile 12 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
161Time profile 10 - Setpoint inputValue °C2 Bytes9.1 temperature (°C)CWTU
162Time profile 12 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
162Time profile 10 - Temperature inputValue °C2 Bytes9.1 temperature (°C)CWTU
163Humidity external sensor inputValue [% RH]2 Bytes9.7 humidity (%)CWTU
164Relative humidity measuredValue [% RH]2 Bytes9.7 humidity (%)CRT
164Relative humidity measuredValue [% RH]2 Bytes9.7 humidity (%)CR
165Relative humidity estimatedValue [% RH]2 Bytes9.7 humidity (%)CRT
165Relative humidity estimatedValue [% RH]2 Bytes9.7 humidity (%)CR
166Specific humidityValue [g/kg]4 Bytes14.5 amplitudeCRT
166Specific humidityValue [g/kg]4 Bytes14.5 amplitudeCR
167Dew point temperatureValue [°C]2 Bytes9.1 temperature (°C)CR
167Dew point temperatureValue [°K]2 Bytes9.2 temperature difference (K)CR
167Dew point temperatureValue [°F]2 Bytes9.27 temperature (°F)CR
167Dew point temperatureValue [°F]2 Bytes9.27 temperature (°F)CRT
167Dew point temperatureValue [°C]2 Bytes9.1 temperature (°C)CRT
167Dew point temperatureValue [°K]2 Bytes9.2 temperature difference (K)CRT
168Dew point temperature alarm enablingEnable/Disable1 Bit1.2 booleanCW
169Dew point temperature alarm enabling statusEnabled/Disabled1 Bit1.3 enableCRT
170Dew point temperature alarm limit regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
171Dew point temperature alarm threshold feedbackValue [°C]2 Bytes9.1 temperature (°C)CRT
171Dew point temperature alarm threshold feedbackValue [°K]2 Bytes9.2 temperature difference (K)CRT
171Dew point temperature alarm threshold feedbackValue [°F]2 Bytes9.27 temperature (°F)CRT
172Dew point temperature alarm outputHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
172Dew point temperature alarm outputOn/Off forced positioning2 Bit2.1 switch controlCRT
172Dew point temperature alarm outputValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
172Dew point temperature alarm outputValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
172Dew point temperature alarm output1/0 value1 Bit1.1 switchCRT
172Dew point temperature alarm outputValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
172Dew point temperature alarm outputValue [0 .. 65535]2 Bytes7.1 pulsesCRT
172Dew point temperature alarm outputValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
173Relative humidity threshold 1 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
173Relative humidity threshold 1 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
174Relative humidity threshold 1 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
175Relative humidity threshold 1 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
175Relative humidity threshold 1 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
176Relative humidity threshold 1 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
177Relative humidity threshold 1 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
177Relative humidity threshold 1 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
177Relative humidity threshold 1 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
177Relative humidity threshold 1 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
177Relative humidity threshold 1 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
177Relative humidity threshold 1 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
177Relative humidity threshold 1 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
177Relative humidity threshold 1 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
177Relative humidity threshold 1 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
177Relative humidity threshold 1 output A1/0 value1 Bit1.1 switchCRT
177Relative humidity threshold 1 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
178Output A relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
178Output A relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
178Output A relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
178Output A relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
178Relative humidity threshold 1 output A statusOn/Off status1 Bit1.1 switchCWTU
179Relative humidity threshold 1 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
179Relative humidity threshold 1 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
179Relative humidity threshold 1 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
179Relative humidity threshold 1 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
179Relative humidity threshold 1 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
179Relative humidity threshold 1 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
179Relative humidity threshold 1 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
179Relative humidity threshold 1 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
179Relative humidity threshold 1 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
179Relative humidity threshold 1 output B1/0 value1 Bit1.1 switchCRT
179Relative humidity threshold 1 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
180Output B relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
180Output B relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
180Output B relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
180Output B relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
180Relative humidity threshold 1 output B statusOn/Off status1 Bit1.1 switchCWTU
181Relative humidity threshold 1 output COn/Off forced positioning2 Bit2.1 switch controlCRT
181Relative humidity threshold 1 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
181Relative humidity threshold 1 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
181Relative humidity threshold 1 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
181Relative humidity threshold 1 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
181Relative humidity threshold 1 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
181Relative humidity threshold 1 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
181Relative humidity threshold 1 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
181Relative humidity threshold 1 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
181Relative humidity threshold 1 output C1/0 value1 Bit1.1 switchCRT
181Relative humidity threshold 1 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
182Output C relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
182Output C relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
182Output C relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
182Output C relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
182Relative humidity threshold 1 output C statusOn/Off status1 Bit1.1 switchCWTU
183Relative humidity threshold 1 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
183Relative humidity threshold 1 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
183Relative humidity threshold 1 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
183Relative humidity threshold 1 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
183Relative humidity threshold 1 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
183Relative humidity threshold 1 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
183Relative humidity threshold 1 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
183Relative humidity threshold 1 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
183Relative humidity threshold 1 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
183Relative humidity threshold 1 output D1/0 value1 Bit1.1 switchCRT
183Relative humidity threshold 1 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
184Output D relative humidity threshold 1 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
184Output D relative humidity threshold 1 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
184Output D relative humidity threshold 1 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
184Output D relative humidity threshold 1 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
184Relative humidity threshold 1 output D statusOn/Off status1 Bit1.1 switchCWTU
185Relative humidity threshold 2 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
185Relative humidity threshold 2 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
186Relative humidity threshold 2 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
187Relative humidity threshold 2 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
187Relative humidity threshold 2 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
188Relative humidity threshold 2 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
189Relative humidity threshold 2 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
189Relative humidity threshold 2 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
189Relative humidity threshold 2 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
189Relative humidity threshold 2 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
189Relative humidity threshold 2 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
189Relative humidity threshold 2 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
189Relative humidity threshold 2 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
189Relative humidity threshold 2 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
189Relative humidity threshold 2 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
189Relative humidity threshold 2 output A1/0 value1 Bit1.1 switchCRT
189Relative humidity threshold 2 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
190Output A relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
190Output A relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
190Output A relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
190Output A relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
190Relative humidity threshold 2 output A statusOn/Off status1 Bit1.1 switchCWTU
191Relative humidity threshold 2 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
191Relative humidity threshold 2 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
191Relative humidity threshold 2 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
191Relative humidity threshold 2 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
191Relative humidity threshold 2 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
191Relative humidity threshold 2 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
191Relative humidity threshold 2 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
191Relative humidity threshold 2 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
191Relative humidity threshold 2 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
191Relative humidity threshold 2 output B1/0 value1 Bit1.1 switchCRT
191Relative humidity threshold 2 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
192Output B relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
192Output B relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
192Output B relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
192Output B relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
192Relative humidity threshold 2 output B statusOn/Off status1 Bit1.1 switchCWTU
193Relative humidity threshold 2 output COn/Off forced positioning2 Bit2.1 switch controlCRT
193Relative humidity threshold 2 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
193Relative humidity threshold 2 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
193Relative humidity threshold 2 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
193Relative humidity threshold 2 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
193Relative humidity threshold 2 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
193Relative humidity threshold 2 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
193Relative humidity threshold 2 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
193Relative humidity threshold 2 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
193Relative humidity threshold 2 output C1/0 value1 Bit1.1 switchCRT
193Relative humidity threshold 2 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
194Output C relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
194Output C relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
194Output C relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
194Output C relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
194Relative humidity threshold 2 output C statusOn/Off status1 Bit1.1 switchCWTU
195Relative humidity threshold 2 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
195Relative humidity threshold 2 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
195Relative humidity threshold 2 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
195Relative humidity threshold 2 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
195Relative humidity threshold 2 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
195Relative humidity threshold 2 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
195Relative humidity threshold 2 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
195Relative humidity threshold 2 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
195Relative humidity threshold 2 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
195Relative humidity threshold 2 output D1/0 value1 Bit1.1 switchCRT
195Relative humidity threshold 2 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
196Output D relative humidity threshold 2 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
196Output D relative humidity threshold 2 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
196Output D relative humidity threshold 2 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
196Output D relative humidity threshold 2 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
196Relative humidity threshold 2 output D statusOn/Off status1 Bit1.1 switchCWTU
197Relative humidity threshold 3 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
197Relative humidity threshold 3 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
198Relative humidity threshold 3 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
199Relative humidity threshold 3 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
199Relative humidity threshold 3 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
200Relative humidity threshold 3 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
201Relative humidity threshold 3 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
201Relative humidity threshold 3 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
201Relative humidity threshold 3 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
201Relative humidity threshold 3 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
201Relative humidity threshold 3 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
201Relative humidity threshold 3 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
201Relative humidity threshold 3 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
201Relative humidity threshold 3 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
201Relative humidity threshold 3 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
201Relative humidity threshold 3 output A1/0 value1 Bit1.1 switchCRT
201Relative humidity threshold 3 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
202Output A relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
202Output A relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
202Output A relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
202Output A relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
202Relative humidity threshold 3 output A statusOn/Off status1 Bit1.1 switchCWTU
203Relative humidity threshold 3 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
203Relative humidity threshold 3 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
203Relative humidity threshold 3 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
203Relative humidity threshold 3 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
203Relative humidity threshold 3 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
203Relative humidity threshold 3 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
203Relative humidity threshold 3 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
203Relative humidity threshold 3 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
203Relative humidity threshold 3 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
203Relative humidity threshold 3 output B1/0 value1 Bit1.1 switchCRT
203Relative humidity threshold 3 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
204Output B relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
204Output B relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
204Output B relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
204Output B relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
204Relative humidity threshold 3 output B statusOn/Off status1 Bit1.1 switchCWTU
205Relative humidity threshold 3 output COn/Off forced positioning2 Bit2.1 switch controlCRT
205Relative humidity threshold 3 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
205Relative humidity threshold 3 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
205Relative humidity threshold 3 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
205Relative humidity threshold 3 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
205Relative humidity threshold 3 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
205Relative humidity threshold 3 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
205Relative humidity threshold 3 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
205Relative humidity threshold 3 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
205Relative humidity threshold 3 output C1/0 value1 Bit1.1 switchCRT
205Relative humidity threshold 3 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
206Output C relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
206Output C relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
206Output C relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
206Output C relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
206Relative humidity threshold 3 output C statusOn/Off status1 Bit1.1 switchCWTU
207Relative humidity threshold 3 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
207Relative humidity threshold 3 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
207Relative humidity threshold 3 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
207Relative humidity threshold 3 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
207Relative humidity threshold 3 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
207Relative humidity threshold 3 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
207Relative humidity threshold 3 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
207Relative humidity threshold 3 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
207Relative humidity threshold 3 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
207Relative humidity threshold 3 output D1/0 value1 Bit1.1 switchCRT
207Relative humidity threshold 3 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
208Output D relative humidity threshold 3 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
208Output D relative humidity threshold 3 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
208Output D relative humidity threshold 3 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
208Output D relative humidity threshold 3 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
208Relative humidity threshold 3 output D statusOn/Off status1 Bit1.1 switchCWTU
209Relative humidity threshold 4 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
209Relative humidity threshold 4 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
210Relative humidity threshold 4 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
211Relative humidity threshold 4 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
211Relative humidity threshold 4 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
212Relative humidity threshold 4 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
213Relative humidity threshold 4 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
213Relative humidity threshold 4 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
213Relative humidity threshold 4 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
213Relative humidity threshold 4 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
213Relative humidity threshold 4 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
213Relative humidity threshold 4 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
213Relative humidity threshold 4 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
213Relative humidity threshold 4 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
213Relative humidity threshold 4 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
213Relative humidity threshold 4 output A1/0 value1 Bit1.1 switchCRT
213Relative humidity threshold 4 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
214Output A relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
214Output A relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
214Output A relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
214Output A relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
214Relative humidity threshold 4 output A statusOn/Off status1 Bit1.1 switchCWTU
215Relative humidity threshold 4 output BOn/Off forced positioning2 Bit2.1 switch controlCRT
215Relative humidity threshold 4 output BValue [0 .. 65535]2 Bytes7.1 pulsesCRT
215Relative humidity threshold 4 output BValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
215Relative humidity threshold 4 output BValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
215Relative humidity threshold 4 output BSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
215Relative humidity threshold 4 output BSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
215Relative humidity threshold 4 output BSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
215Relative humidity threshold 4 output BValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
215Relative humidity threshold 4 output BValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
215Relative humidity threshold 4 output B1/0 value1 Bit1.1 switchCRT
215Relative humidity threshold 4 output BHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
216Output B relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
216Output B relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
216Output B relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
216Output B relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
216Relative humidity threshold 4 output B statusOn/Off status1 Bit1.1 switchCWTU
217Relative humidity threshold 4 output COn/Off forced positioning2 Bit2.1 switch controlCRT
217Relative humidity threshold 4 output CValue [0 .. 65535]2 Bytes7.1 pulsesCRT
217Relative humidity threshold 4 output CValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
217Relative humidity threshold 4 output CValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
217Relative humidity threshold 4 output CSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
217Relative humidity threshold 4 output CSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
217Relative humidity threshold 4 output CSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
217Relative humidity threshold 4 output CValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
217Relative humidity threshold 4 output CValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
217Relative humidity threshold 4 output C1/0 value1 Bit1.1 switchCRT
217Relative humidity threshold 4 output CHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
218Output C relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
218Output C relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
218Output C relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
218Output C relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
218Relative humidity threshold 4 output C statusOn/Off status1 Bit1.1 switchCWTU
219Relative humidity threshold 4 output DOn/Off forced positioning2 Bit2.1 switch controlCRT
219Relative humidity threshold 4 output DValue [0 .. 65535]2 Bytes7.1 pulsesCRT
219Relative humidity threshold 4 output DValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
219Relative humidity threshold 4 output DValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
219Relative humidity threshold 4 output DSetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
219Relative humidity threshold 4 output DSetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
219Relative humidity threshold 4 output DSetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
219Relative humidity threshold 4 output DValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
219Relative humidity threshold 4 output DValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
219Relative humidity threshold 4 output D1/0 value1 Bit1.1 switchCRT
219Relative humidity threshold 4 output DHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
220Output D relative humidity threshold 4 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
220Output D relative humidity threshold 4 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
220Output D relative humidity threshold 4 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
220Output D relative humidity threshold 4 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
220Relative humidity threshold 4 output D statusOn/Off status1 Bit1.1 switchCWTU
221Relative humidity threshold 5 enabling1=Enable/0=Disable1 Bit1.2 booleanCW
221Relative humidity threshold 5 enabling0=Enable/1=Disable1 Bit1.2 booleanCW
222Relative humidity threshold 5 enabling statusEnabled/Disabled1 Bit1.3 enableCRT
223Relative humidity threshold 5 value inputValue [% RH]2 Bytes9.7 humidity (%)CW
223Relative humidity threshold 5 value regulation1 = Increase/0 = Decrease1 Bit1.7 stepCW
224Relative humidity threshold 5 feedbackValue [% RH]2 Bytes9.7 humidity (%)CRT
225Relative humidity threshold 5 output AOn/Off forced positioning2 Bit2.1 switch controlCRT
225Relative humidity threshold 5 output AValue [0 .. 65535]2 Bytes7.1 pulsesCRT
225Relative humidity threshold 5 output AValue [-128 .. 127]1 Byte6.10 counter pulses (-128..127)CRT
225Relative humidity threshold 5 output AValue [-32768 .. 32767]2 Bytes8.1 pulses differenceCRT
225Relative humidity threshold 5 output ASetpoint value [°C]2 Bytes9.1 temperature (°C)CRT
225Relative humidity threshold 5 output ASetpoint value [°K]2 Bytes9.2 temperature difference (K)CRT
225Relative humidity threshold 5 output ASetpoint value [°F]2 Bytes9.27 temperature (°F)CRT
225Relative humidity threshold 5 output AValue [0% .. 100%]1 Byte5.1 percentage (0..100%)CRT
225Relative humidity threshold 5 output AValue [0 .. 255]1 Byte5.10 counter pulses (0..255)CRT
225Relative humidity threshold 5 output A1/0 value1 Bit1.1 switchCRT
225Relative humidity threshold 5 output AHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCRT
226Output A relative humidity threshold 5 referenceHVAC Mode (com/precom/eco/off)1 Byte20.102 HVAC modeCWTU
226Output A relative humidity threshold 5 referenceSetpoint [°C]2 Bytes9.1 temperature (°C)CWTU
226Output A relative humidity threshold 5 referenceSetpoint [°K]2 Bytes9.2 temperature difference (K)CWTU
226Output A relative humidity threshold 5 referenceSetpoint [°F]2 Bytes9.27 temperature (°F)CWTU
226Relative humidity threshold 5 output A statusOn/Off status1 Bit1.1 switchCWTU

First 1000 of 1051 group objects shown. Download the .knxprod for the full list.

Parameters (347)
ParameterTypeDefault
ETS downloadlistBB
Chronothermostat functionlistdisable
Input contacts functionlisttwo auxiliary inputs independent
Parameters local modificationlistdisabled
Day and hour modification via buslistdisable
Day and hour sending via buslistdisabled
- Day/hour sending periodlist1 day
Automatic change Daylight Saving Time/Standard Timelistdisable
- Daylight saving time input object value at downloadliststandard time
Time programmer 1listdisable
Time programmer 2listdisable
Time programmer 3listdisable
Time programmer 4listdisable
Time programmer 5listdisable
Time programmer 6listdisable
Time programmer 7listdisable
Time programmer 8listdisable
Time programmer 9listdisable
Time programmer 10listdisable
Time programmer 11listdisable
Time programmer 12listdisable
Chronothermostat functioninglistautonomous
Functioning type settinglistby local command or via bus
Remote parameters settinglistdisable
- Commands format for HVAC mode settinglist1 byte
-- Reception 1 bit mode con priority > actuallistkeep lower priority objects value
-- Reception 1 bit mode con priority < actuallistupdate object value
- HVAC mode setpoint modification via buslistdisable
- Setpoint regulation step [0.1°C]unsignedInt 1…205
- Temporary setpoint forcing via buslistdisable
-- Setpoint temporary forcing regulation step [0.1°C]unsignedInt 1…205
- Set functioning typelistdisable
Room temperature control throughlistinternal control logic
Control logic Heating/Air coolinglistdifferent (4 pipe)
Heating/Air cooling control algorithmlisttwo points ON-OFF
Heating/air cooling valve status feedbacklistenable
- Commands repetition period with disabled feedbacklist5 minutes
Ripeti comando su cambiamento stato attuatore RISClistenable
Fancoil valves managementlisttwo points ON-OFF
- Heating/air cooling valve status feedbacklistenable
-- Commands repetition period with disabled feedbacklist5 minutes
Fancoil speed modification via buslistdisable
Fancoil mode (automatic/manual) feedbacklistdisable
Heating control algorithmlisttwo points ON-OFF
Air cooling control algorithmlisttwo points ON-OFF
Regulation differential (tenth of °C)unsignedInt 1…202
Thermal gradient auto storinglistdisable
Select heating systemlistfloor heating
- Proportional bandlist2.0 °C
- Integration timelist60 minutes
- Cycle timelist30 minutes
- Min. % variation for continuous command sendinglist5%
Fancoil speed numberlist3
- Regulation differential speed 1 (tenth of °C)unsignedInt 0…202
- Speed 1 inertia time (seconds)unsignedInt 0…100
Fancoil speed status feedbacklistenable
- Command repetition time fancoil speedlist5 minutes
- Regulation differential speed 2 (tenth of °C)unsignedInt 1…202
- Speed 2 inertia time (seconds)unsignedInt 0…100
- Regulation differential speed 3 (tenth of °C)unsignedInt 1…202
- Speed 3 inertia time (seconds)unsignedInt 0…100
Regulation differential valve (tenth of °C)unsignedInt 1…202
Heating 2° stagelistdisabled
- Operation limit 2° stage (tenths of °C)unsignedInt 10…10010
- Regulation differential 2° stage (tenth of °C)unsignedInt 1…202
Heating 2° stage feedbacklistenable
- Command repetition time 2° stage without feedbacklist5 minutes
Ripeti comando su cambiamento stato 2° stadio RISClistenable
Heating valve status feedbacklistenable
- Regulation differential valve (tenth of °C)unsignedInt 1…202
- Heating valve status feedbacklistenable
Select air cooling systemlistceiling cooling
- Proportional bandlist5.0 °C
- Integration timelist240 minutes
air cooling 2° stagelistdisabled
Air cooling 2° stage feedbacklistenable
Ripeti comando su cambiamento stato 2° stadio CONDlistenable
Air cooling valve status feedbacklistenable
Ripeti comando su cambiamento stato attuatore CONDlistenable
- Air cooling valve status feedbacklistenable
Comfort setpoint (tenths of °C)signedInt 50…400200
Precomfort setpoint (tenths of °C)signedInt 50…400180
Economy setpoint (tenths of °C)signedInt 50…400160
Antifreeze setpoint (tenths of °C)signedInt 20…7050
Comfort setpoint (tenths of °C)signedInt 50…400240
Precomfort setpoint (tenths of °C)signedInt 50…400260
Economy setpoint (tenths of °C)signedInt 50…400280
High temperature protection setpoint (tenths of °C)signedInt 300…400350
Behaviour temperature forced positioning at new setpoint receivinglistcancel temperature forced positioning
modify all the setpoints of the same functioning typelistno
modify contemporary the setpoint of the other functioning typelistno
Internal sensor correction factor (tenths of °C)signedInt -20…200
KNX external sensorlistdisabled
- Measure unit KNX external sensorlistCelsius degrees (°C)
- KNX ext. sensor incidence in measured temp. calculationlist10%
- KNX external sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
- Behaviour at KNX external sensor signal absencelistuse last value received
- KNX floor sensor measure unitlistCelsius degrees (°C)
- Threshold temperature temperature alarm (tenth of °C)unsignedInt 150…1000500
- Temperature alarm hysteresis (tenth of °C)unsignedInt 10…10030
- KNX floor sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
- Behaviour at KNX floor sensor signal absencelistactivate temperature alarm
Auxiliary external sensorlistenables temperature sensor
- Type of NTC sensor connectedlistfloating sensor (GW10800)
- Correction factor auxiliary sensor (tenths of °C)signedInt -20…200
- Auxiliary ext. sensor incidence in measured temp. calculationlist10%
- Behaviour at auxiliary external sensor signal absencelistuse last value received
- Auxiliary sensor measured temperaturelistdo not send
-- Measure unit auxiliary sensorlistCelsius degrees (°C)
-- Auxiliary sensor temperature min. variation for sending value [± 0.1 °C]unsignedInt 1…105
-- Auxiliary sensor temperature sending period [minutes]unsignedInt 1…2555
- Behaviour at auxiliary floor sensor signal absencelistactivate temperature alarm
- Temperature measured by auxiliary floor sensorlistdo not send
Measured temperaturelistdo not send
- Measure unitlistCelsius degrees (°C)
- Min. % variation for sending value [± 0.1 °C]unsignedInt 1…105
- Temperature sending period [minutes]unsignedInt 1…2555
HVAC mode feedbacklistdisabled
1 bit HVAC modeliston demand only
1 byte HVAC modeliston demand only
Functioning type feedbacklistdisabled
Current setpoint feedbacklistdisabled
Chronothermostat functioning feedbacklistdisabled
HVAC mode setpoint feedbacklistdisabled
Feedbacks sending trigger objectlistdisable
Scenes functionlistdisable
Scene number 1listunassigned
Scene number 2listunassigned
Scene number 3listunassigned
Scene number 4listunassigned
Scene number 5listunassigned
Scene number 6listunassigned
Scene number 7listunassigned
Scene number 8listunassigned
Parameters to memorize while storinglistHVAC mode only
Slave control objectlistHVAC mode (1 byte)
Send party command to slaveslistdisable
Send holiday command to slaveslistdisable
Temperature measure unitlistCelsius degrees (°C)
Temperature and humidity alternating display on the chronothermostat pagelistdisabled
Automatically back to main page after timeoutlistdisabled
- Idle time for automatic return to main pagelist30 seconds
Public holidaylistsunday
Backlight colourlistwhite
Icons themelistmonochrome
- Icons colour with backlight onlistblue
Retroilluminazione displaylisttimed activation (energy saving)
Backlight deactivation timeout (seconds)unsignedInt 10…18020
Display backlight brightness intensity islistmanually settable
Backlight brightness intensity percentage valuelist80%
- Backlight brightness offset compared to twilight controllist0%
Matched functionlistnone
Sending object formatlist1 bit
- Sending on contact closing detectionlist1
- Sending on contact opening detectionlistno effect
-- Status feedback objectlistdisabled
- Sending on contact closing detectionlistactivate on (down) forcing
- Sending on contact closing detectionlistvalue sending
-- Value (0 .. 255)unsignedInt 0…2550
-- Value (-128 .. +127)signedInt -128…1270
-- Value (0% .. 100%)unsignedInt 0…1000
- Sending on contact closing detectionlistcomfort
-- Value (0 .. 65535)unsignedInt 0…655350
-- Value (-32768 .. +32767)signedInt -32768…327670
-- Value (0 .. 4294967295)unsignedInt 0…42949672950
-- Value (-2147483648 .. +2147483647)signedInt -2147483648…21474836470
-- Value (characters ISO 8859-1)text
- Sending on short operation detectionlist1
- Sending on long operation detectionlistno effect
- Sending on short operation detectionlistvalue sending
- Sending on short operation detectionlistcomfort
Dimmer status feedback objectlistdisable
- Brightness dimming commands with dimmer onlistbrightness increase and decrease
Increase/decrease steplist12.5%
Cyclical sending period [x 0.1s]unsignedInt 3…505
Scene number (0 .. 63)unsignedInt 0…630
Scene storing by long operationlistenabled
Window statuslistclosed if contact is open
Send window contact status feedbacklistdisabled
Matched functionlistdimming with STOP telegram
Uso relè localelistfree
Status information transmissionlistsending on change
- Status transmission on bus voltage recoverylistenable
Relay status at bus voltage failurelistno change
Relay status after bus voltage recoverylistas before voltage drop
- Activation timelist1 min
- Warning timelistno warning
- Relay status on forced positioning endlistfollows last command received
- Forced positioning status at bus voltage recoverylistas before voltage drop
Object format:list1 bit on/off
- Value 1listoff
- Valore 2listoff
- Value 3liston
- Valore 4listoff
- Value 1listup
- Valore 2listup
- Value 3listdown
- Valore 4listup
- Value 1list0
- Valore 2list0
- Value 3list1
- Valore 4list0
- Value 1listdeactivate forcing off (00)
- Value 2listdeactivate forcing off (00)
- Value 3listdeactivate forcing off (00)
- Value 4listdeactivate forcing off (00)
- Value 1 (0 .. 255)unsignedInt 0…2550
- Value 2 (0 .. 255)unsignedInt 0…2550
- Value 3 (0 .. 255)unsignedInt 0…2550
- Value 4 (0 .. 255)unsignedInt 0…2550
- Value 1 (-128 .. +127)signedInt -128…1270
- Value 2 (-128 .. +127)signedInt -128…1270
- Value 3 (-128 .. +127)signedInt -128…1270
- Value 4 (-128 .. +127)signedInt -128…1270
- Value 1list0%
- Value 2list0%
- Value 3list0%
- Value 4list0%
- Value 1listauto
- Value 2listauto
- Value 3listauto
- Value 4listauto
- Value 1listexecute scene 0
- Value 2listexecute scene 0
- Value 3listexecute scene 0
- Value 4listexecute scene 0
- Value 1 (0 .. 65535)unsignedInt 0…655350
- Value 2 (0 .. 65535)unsignedInt 0…655350
- Value 3 (0 .. 65535)unsignedInt 0…655350
- Value 4 (0 .. 65535)unsignedInt 0…655350
- Value 1 (-32768 .. +32767)signedInt -32768…327670
- Value 2 (-32768 .. +32767)signedInt -32768…327670
- Value 3 (-32768 .. +32767)signedInt -32768…327670
- Value 4 (-32768 .. +32767)signedInt -32768…327670
- Value 1 (tenth of °C)unsignedInt 0…4000
- Value 2 (tenth of °C)unsignedInt 0…4000
- Value 3 (tenth of °C)unsignedInt 0…4000
- Value 4 (tenth of °C)unsignedInt 0…4000
- Value 1 (tenth of °K)unsignedInt 2730…31302730
- Value 2 (tenth of °K)unsignedInt 2730…31302730
- Value 3 (tenth of °K)unsignedInt 2730…31302730
- Value 4 (tenth of °K)unsignedInt 2730…31302730
- Value 1 (tenth of °F)unsignedInt 320…1040320
- Value 2 (tenth of °F)unsignedInt 320…1040320
- Value 3 (tenth of °F)unsignedInt 320…1040320
- Value 4 (tenth of °F)unsignedInt 320…1040320
Cyclic sending of value associated to time profilelistdisabled
Preset time profilelistdisable
Switching time 1: HOURSlist09
Switching time 1: MINUTESlist00
Variable value associated at time 1listno effect
Switching time 2: HOURSlist12
Switching time 2: MINUTESlist00
Variable value associated at time 2listno effect
Switching time 3: HOURSlist14
Switching time 3: MINUTESlist00
Variable value associated at time 3listno effect
Switching time 4: HOURSlist18
Switching time 4: MINUTESlist00
Variable value associated at time 4listno effect
Cyclic sending of commands to slaves associated to time profilelistdisabled
HVAC mode associated to time 1listcomfort
HVAC mode associated to time 2listcomfort
HVAC mode associated to time 3listcomfort
HVAC mode associated to time 4listcomfort
Sensore esterno di umidità KNXlistenable
Fattore di correzione sensore interno [% UR]signedInt -10…100
- Incidenza del sensore esterno KNX nel calcolo dell'umidità misuratalist100%
KNX external sensor monitoring time [min] (0= no monitoring)unsignedInt 0…102
Behaviour at KNX external sensor signal absencelistuse last value received
Relative humidity measuredlistdo not send
- Minimum variation for sending value [% RH]list± 5 %
- Relative humidity value repetition time [minutes]unsignedInt 1…2555
Estimate the humidity at the temperature measured by the chronothermostatlistdisable
- Estimated relative humiditylistdo not send
-- Minimum variation for sending value [% RH]list± 5 %
-- Estimated relative humidity value repetition time [minutes]unsignedInt 1…2555
Specific humiditylistdo not send
- Minimum variation for sending valuelist± 5 g/Kg
- Specific relative humidity value repetition time [minutes]unsignedInt 1…2555
Relative humidity threshold 1listdisable
Measure used as reference:listRelative humidity measured
Threshold logic functioning:listhumidification
C1 = Condition 1listRelative humidity <= Limit threshold - hysteresis
C2 = Condition 2listRelative humidity >= Limit threshold
C1 = Condition 1listRelative humidity >= Limit threshold + hysteresis
C2 = Condition 2listRelative humidity <= Limit threshold
Limit threshold starting value [% RH]unsignedInt 0…10050
Limit threshold hysteresis [% RH]unsignedInt 1…205
Change the threshold value via bus throughlistabsolute value
- Threshold regulation step via bus [%]unsignedInt 1…205
Enable/disable the humidity threshold (via bus and device menu)listno
- Threshold activation valuelistvalue "1"
- Threshold activation status after bus voltage recoverylistas before voltage drop
Oggetto A --------------------------------------listenable
Output formatlist1 bit
- On the occurrence of Condition 1listsends 1
- On the occurrence of Condition 2listno effect
- Relative humidity threshold output status feedbacklistenable
- Output commands cyclical repetitionlistdisable
-- Command repetition timelist5 minutes
- On the occurrence of Condition 1listsends active forcing on(down)
- On the occurrence of Condition 1listvalue sending
- On the occurrence of Condition 1listsends comfort
-- Offset (-3 .. 3)signedInt -3…31
- On the occurrence of Condition 1listsends current setpoint ± offset
-- Offset [0.1°C] (-300 .. 300)signedInt -300…30010
Object B --------------------------------------listdisable
Object C --------------------------------------listdisable
Object D --------------------------------------listdisable
Relative humidity threshold 2listdisable
Relative humidity threshold 3listdisable
Relative humidity threshold 4listdisable
Relative humidity threshold 5listdisable
Dew point temperaturelistdo not send
- Feedback measure unitlistCelsius degrees (°C)
- Sending feedback repetition time [minutes]unsignedInt 1…2555
Dew point temperature alarm feedback thresholdlistdisable
- Alarm feedback limit [tenths of °C]unsignedInt 0…10050
- Alarm feedback limit regulation step via bus [0.1°C]unsignedInt 1…1005
- Alarm threshold hysteresis [tenths of °C]unsignedInt 1…2010
- Alarm threshold feedback measure unitlistCelsius degrees (°C)
- Enable/disable the alarm threshold (via bus and device menu)listno
-- Threshold activation valuelistvalue "1"
-- Alarm threshold activation status after bus voltage recoverylistas before voltage drop
- Output formatlist1 bit
-- If Measure temperature < Threshold temperaturelistsends 1
-- If Measure temperature > Threshold temperature + Hysteresislistno effect
-- If Measure temperature < Threshold temperaturelistsends active forcing on(down)
-- If Measure temperature < Threshold temperaturelistvalue sending
--- Value (0 .. 255)unsignedInt 0…2550
--- Value (-128 .. +127)signedInt -128…1270
--- Value (0% .. 100%)unsignedInt 0…1000
-- If Measure temperature < Threshold temperaturelistsends comfort
--- Value (0 .. 65535)unsignedInt 0…655350
--- Value (-32768 .. +32767)signedInt -32768…327670
Enable thermal comfort status feedbacklistenable
The season summer/winterlistfollows active functioning type
- Logical value associated with the seasonslist1 = summer / 0 = winter
- Season active after an ETS downloadlistsummer
Maximum temperature [0.1 °C]signedInt 200…400260
Minimum temperature [0.1 °C]signedInt 100…300240
Maximum relative humidity [% RH]unsignedInt 50…9560
Minimum relative humidity [% RH]unsignedInt 10…4540
Maximum specific humidity [% RH]unsignedInt 50…220115
Maximum temperature [0.1 °C]signedInt 200…400220
Minimum temperature [0.1 °C]signedInt 100…300180

Version history

ApplicationApp noFingerprintFirst seenSizeFile
KNX Chrono/Programmer with humidity S 1.1 1.1 latest$5307384E2026-11-25554 KBDownload

About this file

This is the official ETS product database for the GEWISS GW15794H (GW15794H), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from GEWISS

All GEWISS products