Eelectron AD84C01KNX AD84C01KNX Analog / Digital Module 8 Input / 4 led Output

AD84C01KNX Analog / Digital Module 8 Input / 4 led Output AD84C01KNX

Eelectron · Order number AD84C01KNX · Input/Output Module › Module 8-Input 4-Output

Analog / Digital Module 8 Input / 4 led Output

Download .knxprod AD84C01KNX 1.1 · 500 KB

Product

ManufacturerEelectron
Product nameAD84C01KNX Analog / Digital Module 8 Input / 4 led Output
Order numberAD84C01KNX
Product textAnalog / Digital Module 8 Input / 4 led Output
HardwareAD84C01KNX
MediumTwisted Pair
Bus current (mA)5
Rail mountedNo
RegistrationCertified · 2019-01-22
Languagesfr-FR, it-IT, en-US, de-DE, es-ES, ru-RU
Catalog entryM-006C_H-AD84C01KNX-1_HP-0608-11-E96A_CI-AD84C01KNX-2
FingerprintE96A
SHA-256edcaefeab65005a47598b9684a3e7557aac126ee0ebebb7aba49425f4664db62
First seen2026-11-25
Markets59 markets

Application program: AD84C01KNX 1.1

Application number$0608
Version1.1
Mask versionMV-0021 (2.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters2404
Group objects1161
Group objects (1161)
NoNameFunctionSizeDPTFlags
0<LED 1> CommandOff/On1 Bit1.1 switchCW
1<LED 2> CommandOff/On1 Bit1.1 switchCW
2<LED 3> CommandOff/On1 Bit1.1 switchCW
3<LED 4> CommandOff/On1 Bit1.1 switchCW
4<Input 1> Counter4 Bytes4 Bytes12.1 counter pulses (unsigned)CRT
4<Input 1> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
4<Input 1> Counter2 Bytes2 Bytes7.1 pulsesCRT
4<Input 1> Counter1 Byte1 Byte5.10 counter pulses (0..255)CRT
4<Input 1> Red0-2551 Byte5.10 counter pulses (0..255)CRT
4<Input 1> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
4<Input 1> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
4<Input 1> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
4<Input 1> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
4<Input 1> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
4<Input 1> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
4<Input 1> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
4<Input 1> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
4<Input 1> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
4<Input 1> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
4<Input 1> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
4<Input 1> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
4<Input 1> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
4<Input 1> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
4<Input 1> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
4<Input 1> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
4<Input 1> Closure ActionOff/On1 Bit1.1 switchCRWT
4<Input 1> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
4<Input 1> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
4<Input 1> Dimming On/OffOff/On1 Bit1.1 switchCRWT
4<Input 1> Object AOff/On1 Bit1.1 switchCRT
4<Input 1> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
4<Input 1> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
4<Input 1> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
4<Input 1> Make Up RoomOff/On1 Bit1.1 switchCRT
5<Input 1> Green0-2551 Byte5.10 counter pulses (0..255)CRT
5<Input 1> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
5<Input 1> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
5<Input 1> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
5<Input 1> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
5<Input 1> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
5<Input 1> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
5<Input 1> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
5<Input 1> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
5<Input 1> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
5<Input 1> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
5<Input 1> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
5<Input 1> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
5<Input 1> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
5<Input 1> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
5<Input 1> Long ClosureOff/On1 Bit1.1 switchCRWT
5<Input 1> Opening ActionOff/On1 Bit1.1 switchCRWT
5<Input 1> Object BOff/On1 Bit1.1 switchCRT
5<Input 1> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
5<Input 1> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
5<Input 1> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
5<Input 1> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
5<Input 1> Reset CounterReset1 Bit1.15 resetCW
5<Input 1> Do Not DisturbOff/On1 Bit1.1 switchCRT
6<Input 1> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
6<Input 1> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
6<Input 1> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
6<Input 1> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
6<Input 1> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
6<Input 1> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
6<Input 1> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
6<Input 1> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
6<Input 1> Out Overflow Counter0-2551 Byte5.10 counter pulses (0..255)CRT
6<Input 1> Out Overflow Counter0-100%1 Byte5.1 percentage (0..100%)CRT
6<Input 1> Out Overflow CounterHVAC Mode1 Byte20.102 HVAC modeCRT
6<Input 1> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
6<Input 1> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
6<Input 1> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
6<Input 1> FeedbackOff/On1 Bit1.1 switchCW
6<Input 1> FeedbackUp/Down1 Bit1.8 up/downCW
6<Input 1> Object COff/On1 Bit1.1 switchCRT
6<Input 1> Out Overflow CounterOff/On1 Bit1.1 switchCRT
7<Input 1> Enable InputDisable/Enable1 Bit1.3 enableCW
8<Input 2> Counter4 Bytes4 Bytes12.1 counter pulses (unsigned)CRT
8<Input 2> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
8<Input 2> Counter2 Bytes2 Bytes7.1 pulsesCRT
8<Input 2> Counter1 Byte1 Byte5.10 counter pulses (0..255)CRT
8<Input 2> Red0-2551 Byte5.10 counter pulses (0..255)CRT
8<Input 2> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
8<Input 2> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
8<Input 2> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
8<Input 2> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
8<Input 2> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
8<Input 2> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
8<Input 2> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
8<Input 2> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
8<Input 2> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
8<Input 2> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
8<Input 2> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
8<Input 2> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
8<Input 2> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
8<Input 2> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
8<Input 2> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
8<Input 2> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
8<Input 2> Closure ActionOff/On1 Bit1.1 switchCRWT
8<Input 2> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
8<Input 2> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
8<Input 2> Dimming On/OffOff/On1 Bit1.1 switchCRWT
8<Input 2> Object AOff/On1 Bit1.1 switchCRT
8<Input 2> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
8<Input 2> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
8<Input 2> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
8<Input 2> Make Up RoomOff/On1 Bit1.1 switchCRT
9<Input 2> Green0-2551 Byte5.10 counter pulses (0..255)CRT
9<Input 2> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
9<Input 2> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
9<Input 2> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
9<Input 2> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
9<Input 2> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
9<Input 2> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
9<Input 2> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
9<Input 2> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
9<Input 2> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
9<Input 2> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
9<Input 2> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
9<Input 2> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
9<Input 2> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
9<Input 2> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
9<Input 2> Long ClosureOff/On1 Bit1.1 switchCRWT
9<Input 2> Opening ActionOff/On1 Bit1.1 switchCRWT
9<Input 2> Object BOff/On1 Bit1.1 switchCRT
9<Input 2> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
9<Input 2> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
9<Input 2> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
9<Input 2> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
9<Input 2> Reset CounterReset1 Bit1.15 resetCW
9<Input 2> Do Not DisturbOff/On1 Bit1.1 switchCRT
10<Input 2> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
10<Input 2> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
10<Input 2> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
10<Input 2> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
10<Input 2> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
10<Input 2> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
10<Input 2> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
10<Input 2> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
10<Input 2> Out Overflow Counter0-2551 Byte5.10 counter pulses (0..255)CRT
10<Input 2> Out Overflow Counter0-100%1 Byte5.1 percentage (0..100%)CRT
10<Input 2> Out Overflow CounterHVAC Mode1 Byte20.102 HVAC modeCRT
10<Input 2> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
10<Input 2> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
10<Input 2> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
10<Input 2> FeedbackOff/On1 Bit1.1 switchCW
10<Input 2> FeedbackUp/Down1 Bit1.8 up/downCW
10<Input 2> Object COff/On1 Bit1.1 switchCRT
10<Input 2> Out Overflow CounterOff/On1 Bit1.1 switchCRT
11<Input 2> Enable InputDisable/Enable1 Bit1.3 enableCW
12<Input 3> Counter4 Bytes4 Bytes12.1 counter pulses (unsigned)CRT
12<Input 3> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
12<Input 3> Counter2 Bytes2 Bytes7.1 pulsesCRT
12<Input 3> Counter1 Byte1 Byte5.10 counter pulses (0..255)CRT
12<Input 3> Red0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input 3> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input 3> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input 3> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input 3> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input 3> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input 3> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input 3> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input 3> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input 3> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input 3> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
12<Input 3> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
12<Input 3> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input 3> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input 3> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
12<Input 3> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
12<Input 3> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
12<Input 3> Closure ActionOff/On1 Bit1.1 switchCRWT
12<Input 3> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
12<Input 3> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
12<Input 3> Dimming On/OffOff/On1 Bit1.1 switchCRWT
12<Input 3> Object AOff/On1 Bit1.1 switchCRT
12<Input 3> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
12<Input 3> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
12<Input 3> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
12<Input 3> Make Up RoomOff/On1 Bit1.1 switchCRT
13<Input 3> Green0-2551 Byte5.10 counter pulses (0..255)CRT
13<Input 3> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
13<Input 3> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
13<Input 3> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
13<Input 3> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
13<Input 3> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
13<Input 3> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
13<Input 3> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
13<Input 3> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
13<Input 3> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
13<Input 3> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
13<Input 3> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
13<Input 3> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
13<Input 3> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
13<Input 3> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
13<Input 3> Long ClosureOff/On1 Bit1.1 switchCRWT
13<Input 3> Opening ActionOff/On1 Bit1.1 switchCRWT
13<Input 3> Object BOff/On1 Bit1.1 switchCRT
13<Input 3> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
13<Input 3> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
13<Input 3> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
13<Input 3> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
13<Input 3> Reset CounterReset1 Bit1.15 resetCW
13<Input 3> Do Not DisturbOff/On1 Bit1.1 switchCRT
14<Input 3> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
14<Input 3> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
14<Input 3> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
14<Input 3> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
14<Input 3> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
14<Input 3> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
14<Input 3> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
14<Input 3> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
14<Input 3> Out Overflow Counter0-2551 Byte5.10 counter pulses (0..255)CRT
14<Input 3> Out Overflow Counter0-100%1 Byte5.1 percentage (0..100%)CRT
14<Input 3> Out Overflow CounterHVAC Mode1 Byte20.102 HVAC modeCRT
14<Input 3> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
14<Input 3> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
14<Input 3> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
14<Input 3> FeedbackOff/On1 Bit1.1 switchCW
14<Input 3> FeedbackUp/Down1 Bit1.8 up/downCW
14<Input 3> Object COff/On1 Bit1.1 switchCRT
14<Input 3> Out Overflow CounterOff/On1 Bit1.1 switchCRT
15<Input 3> Enable InputDisable/Enable1 Bit1.3 enableCW
16<Input 4> Counter4 Bytes4 Bytes12.1 counter pulses (unsigned)CRT
16<Input 4> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
16<Input 4> Counter2 Bytes2 Bytes7.1 pulsesCRT
16<Input 4> Counter1 Byte1 Byte5.10 counter pulses (0..255)CRT
16<Input 4> Red0-2551 Byte5.10 counter pulses (0..255)CRT
16<Input 4> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
16<Input 4> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
16<Input 4> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
16<Input 4> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
16<Input 4> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
16<Input 4> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
16<Input 4> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
16<Input 4> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
16<Input 4> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
16<Input 4> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
16<Input 4> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
16<Input 4> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
16<Input 4> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
16<Input 4> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
16<Input 4> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
16<Input 4> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
16<Input 4> Closure ActionOff/On1 Bit1.1 switchCRWT
16<Input 4> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
16<Input 4> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
16<Input 4> Dimming On/OffOff/On1 Bit1.1 switchCRWT
16<Input 4> Object AOff/On1 Bit1.1 switchCRT
16<Input 4> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
16<Input 4> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
16<Input 4> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
16<Input 4> Make Up RoomOff/On1 Bit1.1 switchCRT
17<Input 4> Green0-2551 Byte5.10 counter pulses (0..255)CRT
17<Input 4> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
17<Input 4> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
17<Input 4> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
17<Input 4> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
17<Input 4> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
17<Input 4> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
17<Input 4> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
17<Input 4> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
17<Input 4> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
17<Input 4> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
17<Input 4> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
17<Input 4> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
17<Input 4> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
17<Input 4> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
17<Input 4> Long ClosureOff/On1 Bit1.1 switchCRWT
17<Input 4> Opening ActionOff/On1 Bit1.1 switchCRWT
17<Input 4> Object BOff/On1 Bit1.1 switchCRT
17<Input 4> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
17<Input 4> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
17<Input 4> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
17<Input 4> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
17<Input 4> Reset CounterReset1 Bit1.15 resetCW
17<Input 4> Do Not DisturbOff/On1 Bit1.1 switchCRT
18<Input 4> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
18<Input 4> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
18<Input 4> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
18<Input 4> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
18<Input 4> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
18<Input 4> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
18<Input 4> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
18<Input 4> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
18<Input 4> Out Overflow Counter0-2551 Byte5.10 counter pulses (0..255)CRT
18<Input 4> Out Overflow Counter0-100%1 Byte5.1 percentage (0..100%)CRT
18<Input 4> Out Overflow CounterHVAC Mode1 Byte20.102 HVAC modeCRT
18<Input 4> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
18<Input 4> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
18<Input 4> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
18<Input 4> FeedbackOff/On1 Bit1.1 switchCW
18<Input 4> FeedbackUp/Down1 Bit1.8 up/downCW
18<Input 4> Object COff/On1 Bit1.1 switchCRT
18<Input 4> Out Overflow CounterOff/On1 Bit1.1 switchCRT
19<Input 4> Enable InputDisable/Enable1 Bit1.3 enableCW
20<Input 5> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
20<Input 5> Red0-2551 Byte5.10 counter pulses (0..255)CRT
20<Input 5> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
20<Input 5> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
20<Input 5> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
20<Input 5> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
20<Input 5> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
20<Input 5> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
20<Input 5> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
20<Input 5> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
20<Input 5> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
20<Input 5> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
20<Input 5> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
20<Input 5> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
20<Input 5> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
20<Input 5> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
20<Input 5> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
20<Input 5> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
20<Temperature 5> AlarmDisable/Enable1 Bit1.1 switchCRT
20<Input 5> Closure ActionOff/On1 Bit1.1 switchCRWT
20<Input 5> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
20<Input 5> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
20<Input 5> Dimming On/OffOff/On1 Bit1.1 switchCRWT
20<Input 5> Object AOff/On1 Bit1.1 switchCRT
20<Input 5> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
20<Input 5> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
20<Input 5> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
20<Input 5> Make Up RoomOff/On1 Bit1.1 switchCRT
21<Temperature 5> Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
21<Input 5> Green0-2551 Byte5.10 counter pulses (0..255)CRT
21<Input 5> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
21<Input 5> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
21<Input 5> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
21<Input 5> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
21<Input 5> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
21<Input 5> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
21<Input 5> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
21<Input 5> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
21<Input 5> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
21<Input 5> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
21<Input 5> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
21<Input 5> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
21<Input 5> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
21<Input 5> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
21<Input 5> Long ClosureOff/On1 Bit1.1 switchCRWT
21<Input 5> Opening ActionOff/On1 Bit1.1 switchCRWT
21<Input 5> Object BOff/On1 Bit1.1 switchCRT
21<Input 5> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
21<Input 5> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
21<Input 5> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
21<Input 5> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
21<Input 5> Do Not DisturbOff/On1 Bit1.1 switchCRT
22<Input 5> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
22<Temperature 5> KNX Probe TemperatureValue °C2 Bytes9.1 temperature (°C)CW
22<Input 5> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
22<Input 5> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
22<Input 5> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
22<Input 5> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
22<Input 5> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
22<Input 5> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
22<Input 5> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
22<Input 5> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
22<Input 5> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
22<Input 5> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
22<Input 5> FeedbackOff/On1 Bit1.1 switchCW
22<Input 5> FeedbackUp/Down1 Bit1.8 up/downCW
22<Input 5> Object COff/On1 Bit1.1 switchCRT
23<Input 5> Enable InputDisable/Enable1 Bit1.3 enableCW
23<Thermostat 5> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCW
23<Thermostat 5> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCRT
23<T.Sensor 5> Enable InputDisable/Enable1 Bit1.3 enableCW
24<T.Sensor 5> Setpoint UpperValue °C2 Bytes9.1 temperature (°C)CW
24<Thermostat 5> Window ContactClose/Open1 Bit1.19 window/doorCW
25<Thermostat 5> Comfort ModeOff/On1 Bit1.1 switchCW
25<T.Sensor 5> Telegram UpperOff/On1 Bit1.1 switchCRT
26<T.Sensor 5> Setpoint LowerValue °C2 Bytes9.1 temperature (°C)CW
26<Thermostat 5> HVAC ModeComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCW
27<Thermostat 5> Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
27<T.Sensor 5> Telegram LowerOff/On1 Bit1.1 switchCRT
28<Thermostat 5> Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
28<Thermostat 5> Setpoint AdjustmentValue °C1 Bit1.7 stepCW
29<Thermostat 5> Base SetpointValue °C2 Bytes9.1 temperature (°C)CW
29<Thermostat 5> SP Economy HeatingValue °C2 Bytes9.1 temperature (°C)CW
29<Thermostat 5> SP EconomyValue °C2 Bytes9.1 temperature (°C)CW
30<Thermostat 5> SP Standby HeatingValue °C2 Bytes9.1 temperature (°C)CW
30<Thermostat 5> SP StandbyValue °C2 Bytes9.1 temperature (°C)CW
31<Thermostat 5> SP Comfort HeatingValue °C2 Bytes9.1 temperature (°C)CW
31<Thermostat 5> SP ComfortValue °C2 Bytes9.1 temperature (°C)CW
32<Thermostat 5> SP Economy CoolingValue °C2 Bytes9.1 temperature (°C)CW
33<Thermostat 5> SP Standby CoolingValue °C2 Bytes9.1 temperature (°C)CW
34<Thermostat 5> SP Comfort CoolingValue °C2 Bytes9.1 temperature (°C)CW
35<Thermostat 5> Heating0-100%1 Byte5.1 percentage (0..100%)CRT
35<Thermostat 5> HeatingOff/On1 Bit1.1 switchCRT
35<Fan Coil 5> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
35<Fan Coil 5> Heating ValveOff/On1 Bit1.1 switchCRT
36<Thermostat 5> Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
36<Thermostat 5> CoolingOff/On1 Bit1.1 switchCRT
36<Fan Coil 5> Cooling ValveOff/On1 Bit1.1 switchCRT
37<Thermostat 5> 0-100% 2nd Stage Heating0-100%1 Byte5.1 percentage (0..100%)CRT
37<Thermostat 5> Off/On 2nd Stage HeatingOff/On1 Bit1.1 switchCRT
38<Thermostat 5> 0-100% 2nd Stage Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
38<Thermostat 5> Off/On 2nd Stage CoolingOff/On1 Bit1.1 switchCRT
39<Fan Coil 5> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
39<Fan Coil 5> Speed 1Off/On1 Bit1.1 switchCRT
40<Fan Coil 5> Speed 2Off/On1 Bit1.1 switchCRT
41<Fan Coil 5> Speed 3Off/On1 Bit1.1 switchCRT
42<Fan Coil 5> Set Man/Auto ModeManual (0) / Auto (1)1 Bit1.1 switchCW
43<Fan Coil 5> Force Speed Control in Man Mode0-100%1 Byte5.1 percentage (0..100%)CW
43<Fan Coil 5> Force Value in Man Mode Speed 1Off/On1 Bit1.1 switchCW
44<Fan Coil 5> Force Value in Man Mode Speed 2Off/On1 Bit1.1 switchCW
45<Fan Coil 5> Force Value in Man Mode Speed 3Off/On1 Bit1.1 switchCW
46<Thermostat 5> OFF ThermostatOff/On1 Bit1.1 switchCRWT
47<Fan Coil 5> Ventilation Off/OnOff/On1 Bit1.1 switchCW
48<Additional Valve 5> Percentage0-100%1 Byte5.1 percentage (0..100%)CRT
48<Additional Valve 5> Valve 6 Ways0-100%1 Byte5.1 percentage (0..100%)CRT
48<Additional Valve 5> PWMOff/On1 Bit1.1 switchCRT
49<Input 6> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
49<Input 6> Red0-2551 Byte5.10 counter pulses (0..255)CRT
49<Input 6> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
49<Input 6> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
49<Input 6> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
49<Input 6> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
49<Input 6> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
49<Input 6> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
49<Input 6> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
49<Input 6> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
49<Input 6> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
49<Input 6> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
49<Input 6> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
49<Input 6> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
49<Input 6> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
49<Input 6> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
49<Input 6> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
49<Input 6> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
49<Temperature 6> AlarmDisable/Enable1 Bit1.1 switchCRT
49<Input 6> Closure ActionOff/On1 Bit1.1 switchCRWT
49<Input 6> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
49<Input 6> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
49<Input 6> Dimming On/OffOff/On1 Bit1.1 switchCRWT
49<Input 6> Object AOff/On1 Bit1.1 switchCRT
49<Input 6> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
49<Input 6> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
49<Input 6> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
49<Input 6> Make Up RoomOff/On1 Bit1.1 switchCRT
50<Temperature 6> Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
50<Input 6> Green0-2551 Byte5.10 counter pulses (0..255)CRT
50<Input 6> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
50<Input 6> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
50<Input 6> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
50<Input 6> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
50<Input 6> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
50<Input 6> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
50<Input 6> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
50<Input 6> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
50<Input 6> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
50<Input 6> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
50<Input 6> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
50<Input 6> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
50<Input 6> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
50<Input 6> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
50<Input 6> Long ClosureOff/On1 Bit1.1 switchCRWT
50<Input 6> Opening ActionOff/On1 Bit1.1 switchCRWT
50<Input 6> Object BOff/On1 Bit1.1 switchCRT
50<Input 6> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
50<Input 6> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
50<Input 6> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
50<Input 6> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
50<Input 6> Do Not DisturbOff/On1 Bit1.1 switchCRT
51<Input 6> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
51<Temperature 6> KNX Probe TemperatureValue °C2 Bytes9.1 temperature (°C)CW
51<Input 6> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
51<Input 6> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
51<Input 6> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
51<Input 6> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
51<Input 6> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
51<Input 6> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
51<Input 6> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
51<Input 6> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
51<Input 6> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
51<Input 6> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
51<Input 6> FeedbackOff/On1 Bit1.1 switchCW
51<Input 6> FeedbackUp/Down1 Bit1.8 up/downCW
51<Input 6> Object COff/On1 Bit1.1 switchCRT
52<Input 6> Enable InputDisable/Enable1 Bit1.3 enableCW
52<Thermostat 6> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCW
52<Thermostat 6> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCRT
52<T.Sensor 6> Enable InputDisable/Enable1 Bit1.3 enableCW
53<T.Sensor 6> Setpoint UpperValue °C2 Bytes9.1 temperature (°C)CW
53<Thermostat 6> Window ContactClose/Open1 Bit1.19 window/doorCW
54<Thermostat 6> Comfort ModeOff/On1 Bit1.1 switchCW
54<T.Sensor 6> Telegram UpperOff/On1 Bit1.1 switchCRT
55<T.Sensor 6> Setpoint LowerValue °C2 Bytes9.1 temperature (°C)CW
55<Thermostat 6> HVAC ModeComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCW
56<Thermostat 6> Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
56<T.Sensor 6> Telegram LowerOff/On1 Bit1.1 switchCRT
57<Thermostat 6> Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
57<Thermostat 6> Setpoint AdjustmentValue °C1 Bit1.7 stepCW
58<Thermostat 6> Base SetpointValue °C2 Bytes9.1 temperature (°C)CW
58<Thermostat 6> SP Economy HeatingValue °C2 Bytes9.1 temperature (°C)CW
58<Thermostat 6> SP EconomyValue °C2 Bytes9.1 temperature (°C)CW
59<Thermostat 6> SP Standby HeatingValue °C2 Bytes9.1 temperature (°C)CW
59<Thermostat 6> SP StandbyValue °C2 Bytes9.1 temperature (°C)CW
60<Thermostat 6> SP Comfort HeatingValue °C2 Bytes9.1 temperature (°C)CW
60<Thermostat 6> SP ComfortValue °C2 Bytes9.1 temperature (°C)CW
61<Thermostat 6> SP Economy CoolingValue °C2 Bytes9.1 temperature (°C)CW
62<Thermostat 6> SP Standby CoolingValue °C2 Bytes9.1 temperature (°C)CW
63<Thermostat 6> SP Comfort CoolingValue °C2 Bytes9.1 temperature (°C)CW
64<Thermostat 6> Heating0-100%1 Byte5.1 percentage (0..100%)CRT
64<Thermostat 6> HeatingOff/On1 Bit1.1 switchCRT
64<Fan Coil 6> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
64<Fan Coil 6> Heating ValveOff/On1 Bit1.1 switchCRT
65<Thermostat 6> Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
65<Thermostat 6> CoolingOff/On1 Bit1.1 switchCRT
65<Fan Coil 6> Cooling ValveOff/On1 Bit1.1 switchCRT
66<Thermostat 6> 0-100% 2nd Stage Heating0-100%1 Byte5.1 percentage (0..100%)CRT
66<Thermostat 6> Off/On 2nd Stage HeatingOff/On1 Bit1.1 switchCRT
67<Thermostat 6> 0-100% 2nd Stage Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
67<Thermostat 6> Off/On 2nd Stage CoolingOff/On1 Bit1.1 switchCRT
68<Fan Coil 6> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
68<Fan Coil 6> Speed 1Off/On1 Bit1.1 switchCRT
69<Fan Coil 6> Speed 2Off/On1 Bit1.1 switchCRT
70<Fan Coil 6> Speed 3Off/On1 Bit1.1 switchCRT
71<Fan Coil 6> Set Man/Auto ModeManual (0) / Auto (1)1 Bit1.1 switchCW
72<Fan Coil 6> Force Speed Control in Man Mode0-100%1 Byte5.1 percentage (0..100%)CW
72<Fan Coil 6> Force Value in Man Mode Speed 1Off/On1 Bit1.1 switchCW
73<Fan Coil 6> Force Value in Man Mode Speed 2Off/On1 Bit1.1 switchCW
74<Fan Coil 6> Force Value in Man Mode Speed 3Off/On1 Bit1.1 switchCW
75<Thermostat 6> OFF ThermostatOff/On1 Bit1.1 switchCRWT
76<Fan Coil 6> Ventilation Off/OnOff/On1 Bit1.1 switchCW
77<Additional Valve 6> Percentage0-100%1 Byte5.1 percentage (0..100%)CRT
77<Additional Valve 6> Valve 6 Ways0-100%1 Byte5.1 percentage (0..100%)CRT
77<Additional Valve 6> PWMOff/On1 Bit1.1 switchCRT
78<Input 7> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
78<Input 7> Red0-2551 Byte5.10 counter pulses (0..255)CRT
78<Input 7> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
78<Input 7> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
78<Input 7> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
78<Input 7> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
78<Input 7> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
78<Input 7> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
78<Input 7> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
78<Input 7> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
78<Input 7> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
78<Input 7> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
78<Input 7> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
78<Input 7> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
78<Input 7> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
78<Input 7> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
78<Input 7> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
78<Input 7> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
78<Temperature 7> AlarmDisable/Enable1 Bit1.1 switchCRT
78<Input 7> Closure ActionOff/On1 Bit1.1 switchCRWT
78<Input 7> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
78<Input 7> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
78<Input 7> Dimming On/OffOff/On1 Bit1.1 switchCRWT
78<Input 7> Object AOff/On1 Bit1.1 switchCRT
78<Input 7> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
78<Input 7> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
78<Input 7> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
78<Input 7> Make Up RoomOff/On1 Bit1.1 switchCRT
79<Temperature 7> Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
79<Input 7> Green0-2551 Byte5.10 counter pulses (0..255)CRT
79<Input 7> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
79<Input 7> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
79<Input 7> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
79<Input 7> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
79<Input 7> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
79<Input 7> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
79<Input 7> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
79<Input 7> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
79<Input 7> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
79<Input 7> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
79<Input 7> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
79<Input 7> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
79<Input 7> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
79<Input 7> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
79<Input 7> Long ClosureOff/On1 Bit1.1 switchCRWT
79<Input 7> Opening ActionOff/On1 Bit1.1 switchCRWT
79<Input 7> Object BOff/On1 Bit1.1 switchCRT
79<Input 7> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
79<Input 7> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
79<Input 7> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
79<Input 7> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
79<Input 7> Do Not DisturbOff/On1 Bit1.1 switchCRT
80<Input 7> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
80<Temperature 7> KNX Probe TemperatureValue °C2 Bytes9.1 temperature (°C)CW
80<Input 7> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
80<Input 7> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
80<Input 7> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
80<Input 7> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
80<Input 7> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
80<Input 7> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
80<Input 7> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
80<Input 7> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
80<Input 7> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
80<Input 7> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
80<Input 7> FeedbackOff/On1 Bit1.1 switchCW
80<Input 7> FeedbackUp/Down1 Bit1.8 up/downCW
80<Input 7> Object COff/On1 Bit1.1 switchCRT
81<Input 7> Enable InputDisable/Enable1 Bit1.3 enableCW
81<Thermostat 7> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCW
81<Thermostat 7> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCRT
81<T.Sensor 7> Enable InputDisable/Enable1 Bit1.3 enableCW
82<T.Sensor 7> Setpoint UpperValue °C2 Bytes9.1 temperature (°C)CW
82<Thermostat 7> Window ContactClose/Open1 Bit1.19 window/doorCW
83<Thermostat 7> Comfort ModeOff/On1 Bit1.1 switchCW
83<T.Sensor 7> Telegram UpperOff/On1 Bit1.1 switchCRT
84<T.Sensor 7> Setpoint LowerValue °C2 Bytes9.1 temperature (°C)CW
84<Thermostat 7> HVAC ModeComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCW
85<Thermostat 7> Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
85<T.Sensor 7> Telegram LowerOff/On1 Bit1.1 switchCRT
86<Thermostat 7> Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
86<Thermostat 7> Setpoint AdjustmentValue °C1 Bit1.7 stepCW
87<Thermostat 7> Base SetpointValue °C2 Bytes9.1 temperature (°C)CW
87<Thermostat 7> SP Economy HeatingValue °C2 Bytes9.1 temperature (°C)CW
87<Thermostat 7> SP EconomyValue °C2 Bytes9.1 temperature (°C)CW
88<Thermostat 7> SP Standby HeatingValue °C2 Bytes9.1 temperature (°C)CW
88<Thermostat 7> SP StandbyValue °C2 Bytes9.1 temperature (°C)CW
89<Thermostat 7> SP Comfort HeatingValue °C2 Bytes9.1 temperature (°C)CW
89<Thermostat 7> SP ComfortValue °C2 Bytes9.1 temperature (°C)CW
90<Thermostat 7> SP Economy CoolingValue °C2 Bytes9.1 temperature (°C)CW
91<Thermostat 7> SP Standby CoolingValue °C2 Bytes9.1 temperature (°C)CW
92<Thermostat 7> SP Comfort CoolingValue °C2 Bytes9.1 temperature (°C)CW
93<Thermostat 7> Heating0-100%1 Byte5.1 percentage (0..100%)CRT
93<Thermostat 7> HeatingOff/On1 Bit1.1 switchCRT
93<Fan Coil 7> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
93<Fan Coil 7> Heating ValveOff/On1 Bit1.1 switchCRT
94<Thermostat 7> Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
94<Thermostat 7> CoolingOff/On1 Bit1.1 switchCRT
94<Fan Coil 7> Cooling ValveOff/On1 Bit1.1 switchCRT
95<Thermostat 7> 0-100% 2nd Stage Heating0-100%1 Byte5.1 percentage (0..100%)CRT
95<Thermostat 7> Off/On 2nd Stage HeatingOff/On1 Bit1.1 switchCRT
96<Thermostat 7> 0-100% 2nd Stage Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
96<Thermostat 7> Off/On 2nd Stage CoolingOff/On1 Bit1.1 switchCRT
97<Fan Coil 7> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
97<Fan Coil 7> Speed 1Off/On1 Bit1.1 switchCRT
98<Fan Coil 7> Speed 2Off/On1 Bit1.1 switchCRT
99<Fan Coil 7> Speed 3Off/On1 Bit1.1 switchCRT
100<Fan Coil 7> Set Man/Auto ModeManual (0) / Auto (1)1 Bit1.1 switchCW
101<Fan Coil 7> Force Speed Control in Man Mode0-100%1 Byte5.1 percentage (0..100%)CW
101<Fan Coil 7> Force Value in Man Mode Speed 1Off/On1 Bit1.1 switchCW
102<Fan Coil 7> Force Value in Man Mode Speed 2Off/On1 Bit1.1 switchCW
103<Fan Coil 7> Force Value in Man Mode Speed 3Off/On1 Bit1.1 switchCW
104<Thermostat 7> OFF ThermostatOff/On1 Bit1.1 switchCRWT
105<Fan Coil 7> Ventilation Off/OnOff/On1 Bit1.1 switchCW
106<Additional Valve 7> Percentage0-100%1 Byte5.1 percentage (0..100%)CRT
106<Additional Valve 7> Valve 6 Ways0-100%1 Byte5.1 percentage (0..100%)CRT
106<Additional Valve 7> PWMOff/On1 Bit1.1 switchCRT
107<Input 8> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
107<Input 8> Red0-2551 Byte5.10 counter pulses (0..255)CRT
107<Input 8> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
107<Input 8> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
107<Input 8> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
107<Input 8> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
107<Input 8> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
107<Input 8> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
107<Input 8> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
107<Input 8> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
107<Input 8> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
107<Input 8> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
107<Input 8> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
107<Input 8> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
107<Input 8> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
107<Input 8> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
107<Input 8> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
107<Input 8> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
107<Temperature 8> AlarmDisable/Enable1 Bit1.1 switchCRT
107<Input 8> Closure ActionOff/On1 Bit1.1 switchCRWT
107<Input 8> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
107<Input 8> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
107<Input 8> Dimming On/OffOff/On1 Bit1.1 switchCRWT
107<Input 8> Object AOff/On1 Bit1.1 switchCRT
107<Input 8> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
107<Input 8> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
107<Input 8> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
107<Input 8> Make Up RoomOff/On1 Bit1.1 switchCRT
108<Temperature 8> Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
108<Input 8> Green0-2551 Byte5.10 counter pulses (0..255)CRT
108<Input 8> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
108<Input 8> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
108<Input 8> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
108<Input 8> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
108<Input 8> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
108<Input 8> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
108<Input 8> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
108<Input 8> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
108<Input 8> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
108<Input 8> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
108<Input 8> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
108<Input 8> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
108<Input 8> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
108<Input 8> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
108<Input 8> Long ClosureOff/On1 Bit1.1 switchCRWT
108<Input 8> Opening ActionOff/On1 Bit1.1 switchCRWT
108<Input 8> Object BOff/On1 Bit1.1 switchCRT
108<Input 8> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
108<Input 8> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
108<Input 8> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
108<Input 8> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
108<Input 8> Do Not DisturbOff/On1 Bit1.1 switchCRT
109<Input 8> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
109<Temperature 8> KNX Probe TemperatureValue °C2 Bytes9.1 temperature (°C)CW
109<Input 8> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
109<Input 8> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
109<Input 8> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
109<Input 8> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
109<Input 8> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
109<Input 8> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
109<Input 8> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
109<Input 8> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
109<Input 8> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
109<Input 8> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
109<Input 8> FeedbackOff/On1 Bit1.1 switchCW
109<Input 8> FeedbackUp/Down1 Bit1.8 up/downCW
109<Input 8> Object COff/On1 Bit1.1 switchCRT
110<Input 8> Enable InputDisable/Enable1 Bit1.3 enableCW
110<Thermostat 8> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCW
110<Thermostat 8> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCRT
110<T.Sensor 8> Enable InputDisable/Enable1 Bit1.3 enableCW
111<T.Sensor 8> Setpoint UpperValue °C2 Bytes9.1 temperature (°C)CW
111<Thermostat 8> Window ContactClose/Open1 Bit1.19 window/doorCW
112<Thermostat 8> Comfort ModeOff/On1 Bit1.1 switchCW
112<T.Sensor 8> Telegram UpperOff/On1 Bit1.1 switchCRT
113<T.Sensor 8> Setpoint LowerValue °C2 Bytes9.1 temperature (°C)CW
113<Thermostat 8> HVAC ModeComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCW
114<Thermostat 8> Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
114<T.Sensor 8> Telegram LowerOff/On1 Bit1.1 switchCRT
115<Thermostat 8> Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
115<Thermostat 8> Setpoint AdjustmentValue °C1 Bit1.7 stepCW
116<Thermostat 8> Base SetpointValue °C2 Bytes9.1 temperature (°C)CW
116<Thermostat 8> SP Economy HeatingValue °C2 Bytes9.1 temperature (°C)CW
116<Thermostat 8> SP EconomyValue °C2 Bytes9.1 temperature (°C)CW
117<Thermostat 8> SP Standby HeatingValue °C2 Bytes9.1 temperature (°C)CW
117<Thermostat 8> SP StandbyValue °C2 Bytes9.1 temperature (°C)CW
118<Thermostat 8> SP Comfort HeatingValue °C2 Bytes9.1 temperature (°C)CW
118<Thermostat 8> SP ComfortValue °C2 Bytes9.1 temperature (°C)CW
119<Thermostat 8> SP Economy CoolingValue °C2 Bytes9.1 temperature (°C)CW
120<Thermostat 8> SP Standby CoolingValue °C2 Bytes9.1 temperature (°C)CW
121<Thermostat 8> SP Comfort CoolingValue °C2 Bytes9.1 temperature (°C)CW
122<Thermostat 8> Heating0-100%1 Byte5.1 percentage (0..100%)CRT
122<Thermostat 8> HeatingOff/On1 Bit1.1 switchCRT
122<Fan Coil 8> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
122<Fan Coil 8> Heating ValveOff/On1 Bit1.1 switchCRT
123<Thermostat 8> Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
123<Thermostat 8> CoolingOff/On1 Bit1.1 switchCRT
123<Fan Coil 8> Cooling ValveOff/On1 Bit1.1 switchCRT
124<Thermostat 8> 0-100% 2nd Stage Heating0-100%1 Byte5.1 percentage (0..100%)CRT
124<Thermostat 8> Off/On 2nd Stage HeatingOff/On1 Bit1.1 switchCRT
125<Thermostat 8> 0-100% 2nd Stage Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
125<Thermostat 8> Off/On 2nd Stage CoolingOff/On1 Bit1.1 switchCRT
126<Fan Coil 8> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
126<Fan Coil 8> Speed 1Off/On1 Bit1.1 switchCRT
127<Fan Coil 8> Speed 2Off/On1 Bit1.1 switchCRT
128<Fan Coil 8> Speed 3Off/On1 Bit1.1 switchCRT
129<Fan Coil 8> Set Man/Auto ModeManual (0) / Auto (1)1 Bit1.1 switchCW
130<Fan Coil 8> Force Speed Control in Man Mode0-100%1 Byte5.1 percentage (0..100%)CW
130<Fan Coil 8> Force Value in Man Mode Speed 1Off/On1 Bit1.1 switchCW
131<Fan Coil 8> Force Value in Man Mode Speed 2Off/On1 Bit1.1 switchCW
132<Fan Coil 8> Force Value in Man Mode Speed 3Off/On1 Bit1.1 switchCW
133<Thermostat 8> OFF ThermostatOff/On1 Bit1.1 switchCRWT
134<Fan Coil 8> Ventilation Off/OnOff/On1 Bit1.1 switchCW
135<Additional Valve 8> Percentage0-100%1 Byte5.1 percentage (0..100%)CRT
135<Additional Valve 8> Valve 6 Ways0-100%1 Byte5.1 percentage (0..100%)CRT
135<Additional Valve 8> PWMOff/On1 Bit1.1 switchCRT
136<Logic 1> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
136<Logic 1> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
136<Logic 1> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
136<Logic 1> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
136<Logic 1> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
136<Logic 1> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
136<Logic 1> Input TemperatureValue °C2 Bytes9.1 temperature (°C)CW
136<Logic 1> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
136<Logic 1> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
136<Logic 1> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
136<Logic 1> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
136<Logic 1> Input Value %Value %1 Byte5.1 percentage (0..100%)CW
136<Logic 1> Output1 Bit1 Bit1.2 booleanCRT
136<Logic 1> OutputLogic1 Bit1.2 booleanCRT
136<Logic 1> Output BitOutput Bit1 Bit1.2 booleanCRT
137<Logic 1> Input4 Bytes4 Bytes14.56 power (W)CW
137<Logic 1> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
137<Logic 1> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
137<Logic 1> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
137<Logic 1> Input2 Bytes2 Bytes9.1 temperature (°C)CW
137<Logic 1> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
137<Logic 1> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
137<Logic 1> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
137<Logic 1> Input SetpointValue °C2 Bytes9.1 temperature (°C)CW
137<Logic 1> Input Relative HumidityHumidity %2 Bytes9.7 humidity (%)CW
137<Logic 1> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
137<Logic 1> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
137<Logic 1> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
137<Logic 1> InputLogic1 Bit1.2 booleanCW
137<Logic 1> Input ALogic1 Bit1.2 booleanCW
137<Logic 1> Input1 Bit1 Bit1.2 booleanCW
137<Logic 1> Input A BitInput A Bit1 Bit1.2 booleanCW
137<Logic 1> Input Speed 1Off/On1 Bit1.1 switchCW
137<Logic 1> Output Speed 1Off/On1 Bit1.1 switchCRT
138<Logic 1> Input B 4Byte CountInput B 4Byte Count4 Bytes13.1 counter pulses (signed)CW
138<Logic 1> Input B 4Byte UCountInput B 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
138<Logic 1> Input B 4Byte FloatInput B 4Byte Float4 Bytes14.56 power (W)CW
138<Logic 1> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
138<Logic 1> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
138<Logic 1> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
138<Logic 1> Input Regulation TemperatureValue °C2 Bytes9.1 temperature (°C)CW
138<Logic 1> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
138<Logic 1> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
138<Logic 1> Input BLogic1 Bit1.2 booleanCW
138<Logic 1> Input B BitInput B Bit1 Bit1.2 booleanCW
138<Logic 1> Input Heat/CoolHeat/Cool1 Bit1.100 heating/coolingCW
138<Logic 1> Input Speed 2Off/On1 Bit1.1 switchCW
138<Logic 1> Output Speed 2Off/On1 Bit1.1 switchCRT
139<Logic 1> Input C 4Byte CountInput C 4Byte Count4 Bytes13.1 counter pulses (signed)CW
139<Logic 1> Input C 4Byte UCountInput C 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
139<Logic 1> Input C 4Byte FloatInput C 4Byte Float4 Bytes14.56 power (W)CW
139<Logic 1> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
139<Logic 1> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
139<Logic 1> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
139<Logic 1> Output Dew Point TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
139<Logic 1> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
139<Logic 1> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
139<Logic 1> Output Valve %Value %1 Byte5.1 percentage (0..100%)CRT
139<Logic 1> Output Heat Valve %Value %1 Byte5.1 percentage (0..100%)CRT
139<Logic 1> Input C BitInput C Bit1 Bit1.2 booleanCW
139<Logic 1> Input Speed 3Off/On1 Bit1.1 switchCW
139<Logic 1> Output Speed 3Off/On1 Bit1.1 switchCRT
140<Logic 1> Input D 4Byte CountInput D 4Byte Count4 Bytes13.1 counter pulses (signed)CW
140<Logic 1> Input D 4Byte UCountInput D 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
140<Logic 1> Input D 4Byte FloatInput D 4Byte Float4 Bytes14.56 power (W)CW
140<Logic 1> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
140<Logic 1> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
140<Logic 1> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
140<Logic 1> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
140<Logic 1> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
140<Logic 1> Output Cool Valve %Value %1 Byte5.1 percentage (0..100%)CRT
140<Logic 1> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
140<Logic 1> Input D BitInput D Bit1 Bit1.2 booleanCW
140<Logic 1> Input Enable/DisableDisable/Enable1 Bit1.3 enableCW
140<Logic 1> Output CommandOff/On1 Bit1.1 switchCRT
141<Logic 2> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
141<Logic 2> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
141<Logic 2> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
141<Logic 2> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
141<Logic 2> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
141<Logic 2> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
141<Logic 2> Input TemperatureValue °C2 Bytes9.1 temperature (°C)CW
141<Logic 2> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
141<Logic 2> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
141<Logic 2> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
141<Logic 2> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
141<Logic 2> Input Value %Value %1 Byte5.1 percentage (0..100%)CW
141<Logic 2> Output1 Bit1 Bit1.2 booleanCRT
141<Logic 2> OutputLogic1 Bit1.2 booleanCRT
141<Logic 2> Output BitOutput Bit1 Bit1.2 booleanCRT
141<VH> Room BookedRoom Booked1 Bit1.2 booleanCW
142<Logic 2> Input4 Bytes4 Bytes14.56 power (W)CW
142<Logic 2> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
142<Logic 2> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
142<Logic 2> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
142<Logic 2> Input2 Bytes2 Bytes9.1 temperature (°C)CW
142<Logic 2> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
142<Logic 2> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
142<Logic 2> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
142<Logic 2> Input SetpointValue °C2 Bytes9.1 temperature (°C)CW
142<Logic 2> Input Relative HumidityHumidity %2 Bytes9.7 humidity (%)CW
142<Logic 2> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
142<Logic 2> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
142<Logic 2> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
142<Logic 2> InputLogic1 Bit1.2 booleanCW
142<Logic 2> Input ALogic1 Bit1.2 booleanCW
142<Logic 2> Input1 Bit1 Bit1.2 booleanCW
142<Logic 2> Input A BitInput A Bit1 Bit1.2 booleanCW
142<Logic 2> Input Speed 1Off/On1 Bit1.1 switchCW
142<Logic 2> Output Speed 1Off/On1 Bit1.1 switchCRT
142<VH> Remote Inputs Enable (Global Enable)Remote Inputs Enable (Global Enable)1 Bit1.2 booleanCW
143<Logic 2> Input B 4Byte CountInput B 4Byte Count4 Bytes13.1 counter pulses (signed)CW
143<Logic 2> Input B 4Byte UCountInput B 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
143<Logic 2> Input B 4Byte FloatInput B 4Byte Float4 Bytes14.56 power (W)CW
143<Logic 2> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
143<Logic 2> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
143<Logic 2> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
143<Logic 2> Input Regulation TemperatureValue °C2 Bytes9.1 temperature (°C)CW
143<Logic 2> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
143<Logic 2> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
143<Logic 2> Input BLogic1 Bit1.2 booleanCW
143<Logic 2> Input B BitInput B Bit1 Bit1.2 booleanCW
143<Logic 2> Input Heat/CoolHeat/Cool1 Bit1.100 heating/coolingCW
143<Logic 2> Input Speed 2Off/On1 Bit1.1 switchCW
143<Logic 2> Output Speed 2Off/On1 Bit1.1 switchCRT
143<VH> Presence OutputPresence Output1 Bit1.2 booleanCRT
144<Logic 2> Input C 4Byte CountInput C 4Byte Count4 Bytes13.1 counter pulses (signed)CW
144<Logic 2> Input C 4Byte UCountInput C 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
144<Logic 2> Input C 4Byte FloatInput C 4Byte Float4 Bytes14.56 power (W)CW
144<Logic 2> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
144<Logic 2> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
144<Logic 2> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
144<Logic 2> Output Dew Point TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
144<Logic 2> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
144<Logic 2> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
144<Logic 2> Output Valve %Value %1 Byte5.1 percentage (0..100%)CRT
144<Logic 2> Output Heat Valve %Value %1 Byte5.1 percentage (0..100%)CRT
144<VH> HVAC OutputHVAC Output1 Byte20.102 HVAC modeCRT
144<Logic 2> Input C BitInput C Bit1 Bit1.2 booleanCW
144<Logic 2> Input Speed 3Off/On1 Bit1.1 switchCW
144<Logic 2> Output Speed 3Off/On1 Bit1.1 switchCRT
145<Logic 2> Input D 4Byte CountInput D 4Byte Count4 Bytes13.1 counter pulses (signed)CW
145<Logic 2> Input D 4Byte UCountInput D 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
145<Logic 2> Input D 4Byte FloatInput D 4Byte Float4 Bytes14.56 power (W)CW
145<Logic 2> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
145<Logic 2> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
145<Logic 2> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
145<Logic 2> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
145<Logic 2> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
145<Logic 2> Output Cool Valve %Value %1 Byte5.1 percentage (0..100%)CRT
145<Logic 2> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
145<VH> Additional OutputAdditional Output1 Byte5.10 counter pulses (0..255)CRT
145<Logic 2> Input D BitInput D Bit1 Bit1.2 booleanCW
145<Logic 2> Input Enable/DisableDisable/Enable1 Bit1.3 enableCW
145<Logic 2> Output CommandOff/On1 Bit1.1 switchCRT
146<Logic 3> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
146<Logic 3> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
146<Logic 3> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
146<Logic 3> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
146<Logic 3> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
146<Logic 3> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
146<Logic 3> Input TemperatureValue °C2 Bytes9.1 temperature (°C)CW
146<Logic 3> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
146<Logic 3> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
146<Logic 3> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
146<Logic 3> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
146<Logic 3> Input Value %Value %1 Byte5.1 percentage (0..100%)CW
146<Logic 3> Output1 Bit1 Bit1.2 booleanCRT
146<Logic 3> OutputLogic1 Bit1.2 booleanCRT
146<Logic 3> Output BitOutput Bit1 Bit1.2 booleanCRT
147<Logic 3> Input4 Bytes4 Bytes14.56 power (W)CW
147<Logic 3> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
147<Logic 3> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
147<Logic 3> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
147<Logic 3> Input2 Bytes2 Bytes9.1 temperature (°C)CW
147<Logic 3> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
147<Logic 3> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
147<Logic 3> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
147<Logic 3> Input SetpointValue °C2 Bytes9.1 temperature (°C)CW
147<Logic 3> Input Relative HumidityHumidity %2 Bytes9.7 humidity (%)CW
147<Logic 3> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
147<Logic 3> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
147<Logic 3> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
147<Logic 3> InputLogic1 Bit1.2 booleanCW
147<Logic 3> Input ALogic1 Bit1.2 booleanCW
147<Logic 3> Input1 Bit1 Bit1.2 booleanCW
147<Logic 3> Input A BitInput A Bit1 Bit1.2 booleanCW
147<Logic 3> Input Speed 1Off/On1 Bit1.1 switchCW
147<Logic 3> Output Speed 1Off/On1 Bit1.1 switchCRT
147<VH> Presence for Guest (Type1)Presence for Guest (Type1)1 Bit1.2 booleanCRT
148<Logic 3> Input B 4Byte CountInput B 4Byte Count4 Bytes13.1 counter pulses (signed)CW
148<Logic 3> Input B 4Byte UCountInput B 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
148<Logic 3> Input B 4Byte FloatInput B 4Byte Float4 Bytes14.56 power (W)CW
148<Logic 3> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
148<Logic 3> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
148<Logic 3> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
148<Logic 3> Input Regulation TemperatureValue °C2 Bytes9.1 temperature (°C)CW
148<Logic 3> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
148<Logic 3> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
148<Logic 3> Input BLogic1 Bit1.2 booleanCW
148<Logic 3> Input B BitInput B Bit1 Bit1.2 booleanCW
148<Logic 3> Input Heat/CoolHeat/Cool1 Bit1.100 heating/coolingCW
148<Logic 3> Input Speed 2Off/On1 Bit1.1 switchCW
148<Logic 3> Output Speed 2Off/On1 Bit1.1 switchCRT
148<VH> Signal Guest (Type1)Signal Guest (Type1)1 Bit1.2 booleanCW
149<Logic 3> Input C 4Byte CountInput C 4Byte Count4 Bytes13.1 counter pulses (signed)CW
149<Logic 3> Input C 4Byte UCountInput C 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
149<Logic 3> Input C 4Byte FloatInput C 4Byte Float4 Bytes14.56 power (W)CW
149<Logic 3> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
149<Logic 3> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
149<Logic 3> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
149<Logic 3> Output Dew Point TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
149<Logic 3> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
149<Logic 3> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
149<Logic 3> Output Valve %Value %1 Byte5.1 percentage (0..100%)CRT
149<Logic 3> Output Heat Valve %Value %1 Byte5.1 percentage (0..100%)CRT
149<Logic 3> Input C BitInput C Bit1 Bit1.2 booleanCW
149<Logic 3> Input Speed 3Off/On1 Bit1.1 switchCW
149<Logic 3> Output Speed 3Off/On1 Bit1.1 switchCRT
149<VH> Presence for Service (Type2)Presence for Service (Type2)1 Bit1.2 booleanCRT
150<Logic 3> Input D 4Byte CountInput D 4Byte Count4 Bytes13.1 counter pulses (signed)CW
150<Logic 3> Input D 4Byte UCountInput D 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
150<Logic 3> Input D 4Byte FloatInput D 4Byte Float4 Bytes14.56 power (W)CW
150<Logic 3> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
150<Logic 3> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
150<Logic 3> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
150<Logic 3> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
150<Logic 3> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
150<Logic 3> Output Cool Valve %Value %1 Byte5.1 percentage (0..100%)CRT
150<Logic 3> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
150<Logic 3> Input D BitInput D Bit1 Bit1.2 booleanCW
150<Logic 3> Input Enable/DisableDisable/Enable1 Bit1.3 enableCW
150<Logic 3> Output CommandOff/On1 Bit1.1 switchCRT
150<VH> Signal Service (Type2)Signal Service (Type2)1 Bit1.2 booleanCW
151<Logic 4> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
151<Logic 4> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
151<Logic 4> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
151<Logic 4> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
151<Logic 4> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
151<Logic 4> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT

First 1000 of 1161 group objects shown. Download the .knxprod for the full list.

Parameters (305)
ParameterTypeDefault
Delay to send telegrams on power up [s]unsignedInt 5…155
Input 5listdigital
Input 6listdigital
Input 7listdigital
Input 8listdigital
Temperature alarm object 5listdisabled
Temperature alarm object 6listdisabled
Temperature alarm object 7listdisabled
Temperature alarm object 8listdisabled
Virtual holderlistdisabled
Temperature functionlistthermostat
LED configurationlistalways off
LED activation telegramlisttelegram "1"
LED initial Statelistoff
LED blink periodlistfixed
Functionlistnothing
Contact typelistnormally open
Debounce time for inputslist80 ms
Object enablelistdisabled
Initial enable statelistenabled
Enable activation telegramlisttelegram "1"
Telegram associatedlist1 bit
Long or short cyclic timeslistshort
Command associated with closureliston
Cyclic sending when contact closedlistnever
Feedback objectlistdisabled
Command associated with closurelistvalue 0-100%
Value associated with closureunsignedInt 0…2550
Value associated with closurelist0%
Value associated with closurelistauto
Command associated with closurelistnothing
Command associated with openinglistnothing
Command typelistvalue 0-100%
Value associated with openingunsignedInt 0…2550
Value associated with openinglist0%
Value associated with openinglistauto
Communication object on openinglistdisabled
Cyclic sending when contact openedlistnever
Minimum time long closurelist0.5 s
Command associated with short closurelistnothing
Command associated with long closurelistnothing
Value associated with short closureunsignedInt 0…2550
Value associated with short closurelist0%
Value associated with short closurelistauto
Value associated with long closureunsignedInt 0…2550
Value associated with long closurelist0%
Value associated with long closurelistauto
Communication object on long closurelistdisabled
Dimming modelistbrighter/darker
Dimming steplistmaximum brightness
Dimming steplistminimum brightness
Dimming steplistmaximum/minimum brightness
Command drive shutterlistmove up/move down
Minimum time long closurelist2.0 s
Scene number (1-64)list1
Store scene on long closurelistdisabled
Object enable scene learning from buslistdisabled
Delay between commandsunsignedInt 0…2550
Telegram associated with command Alist1 bit
Telegram associated with command Blist1 bit
Telegram associated with command Clist1 bit
Command typelistnothing
Value associated with operation 1unsignedInt 0…2550
Value associated with operation 1list0%
Value associated with operation 1listauto
Value associated with operation 2unsignedInt 0…2550
Value associated with operation 2list0%
Value associated with operation 2listauto
Command associated with operation 1listnothing
Command associated with operation 2listnothing
Number of objectslist2 objects
Send only changed objectslistdisabled
Number of steps in the sequencelist2
Long closure to restart sequencelistdisabled
Min. time long closure to restart sequencelist1.0 s
Restart functionlistrestart and send first
Value step longlista=off b=off c=off
Value step longlista=off b=off
Value step 1lista=off b=off c=off
Value step 2lista=off b=off c=off
Value step 3lista=off b=off c=off
Value step 4lista=off b=off c=off
Value step 5lista=off b=off c=off
Value step 6lista=off b=off c=off
Value step 7lista=off b=off c=off
Value step 8lista=off b=off c=off
Value step 1lista=off b=off
Value step 2lista=off b=off
Value step 3lista=off b=off
Value step 4lista=off b=off
Software filter frequencylistno filter
Counter input sizelist1 byte
Condition of increase counterlistrising edge
Send counter on time baselistno cyclic sending
Send counter on variation base (0=Disable)unsignedInt 0…2551
Telegram associated to overflowlistnothing
End counter valueunsignedInt 1…255255
End counter valueunsignedInt 1…6553565535
End counter valueunsignedInt 1…42949672954294967295
Start counter valueunsignedInt 0…2540
Start counter valueunsignedInt 0…655340
Start counter valueunsignedInt 0…42949672940
Command associatedlistoff
Command typelistvalue 0-255
Value associated of overflowunsignedInt 0…2550
Value associated of overflowlist0%
Value associated of overflowlistauto
Set valuelistred
Long closure to change colorlistlong closure disabled
Enable sending colors during transitionslistdisabled
RGB objects typelist3 objects of 1 byte
Command associatedlistreset all
Action associated with closurelistenable
Color associated to "reset all"text#FFFFFF
Color associated to "make up room"text#00FF00
Color associated to "do not disturb"text#FF0000
Additional objectlistnone
Active edgelistsend on closing
Number of valueslist3 values
Value AunsignedInt 0…2550
Value BunsignedInt 0…2551
Value CunsignedInt 0…2552
Value DunsignedInt 0…2553
Value EunsignedInt 0…2554
Value FunsignedInt 0…2555
Value GunsignedInt 0…2556
Value HunsignedInt 0…2557
Value IunsignedInt 0…2558
Use thermostat to control fan coilslistyes
Fan coil typelistfan coil control on / off
Enable 2nd stage controllistdisabled
Thermostat control modelistHVAC mode (switched heat/cool)
Value of heat/cool object after downloadlist1 = heating
Value of HVAC mode object after downloadlistoff (frost / high temperature protection)
Enable 1bit comfort objectlistdisabled
Control type when comfort endsliststandby
Comfort object prioritylistno
Comfort object timinglisttime unlimited
Comfort overwrite time [min]unsignedInt 1…2551
Enable setpoint adjustment objectlistenabled
Window contactlistdisabled
Window contact activation telegramlisttelegram "1"
Thermostat OFF objectlistdisabled
Thermostat OFF activation telegramlisttelegram "1"
Setpoint frost protectionlist7°C
Setpoint economy heating (Teh)list16°C
Setpoint standby heating (Tsh)list18°C
Setpoint comfort heating (Tch)list20°C
Setpoint high temperature protectionlist35°C
Setpoint economy cooling (Tec)list28°C
Setpoint standby cooling (Tsc)list26°C
Setpoint comfort cooling (Tcc)list24°C
Action to execute for setpointlistmodify absolute
Value of base setpoint object after downloadlist20°C
Dead bandlist2°C
Control algorithmlist2 points on/off control
Time period for on/off cyclic sendinglistno cyclic sending
Regulation differential value - heatinglist0.4°C
Proportional band [Bp]list1°C
Cycle timelist10 min
Integration time [min] [Ti]unsignedInt 5…250200
Regulation differential value - coolinglist0.4°C
Reset SP adjustment on HEAT/COOL changelistreset
Reset SP adjustment on HVAC economylistno reset
Adjustment allowedlist-/+ 3°C
Setpoint adjustment value formatlist2 bytes object - temperature value
Increase setpoint adjustment withlisttelegram "1"
Resolutionlist0.5°C
Keep SP adjustment on power uplistenabled
Enable fancoil speeds onlistheating / cooling
System typelist2 pipes
Enable additional valvelistdisabled
Speed numberlist3 speed
Regulation differential value S1-SP heatlist0°C
Regulation differential value SP-S1 coollist0°C
Regulation differential value S1-S2 heatlist0.8°C
Regulation differential value S2-S1 coollist0.8°C
Regulation differential value S2-S3 heatlist0.8°C
Regulation differential value S3-S2 coollist0.8°C
Manage valve independentlylistno
Regulation differential valve-cool-ONlist0.8°C
Regulation differential valve-heat-ONlist0.8°C
Regulation differential valve-cool-OFFlist0.8°C
Regulation differential valve-heat-OFFlist0.8°C
Initial value MAN (0) / AUTO (1) objectlist1
Enable ventilation object on/offlistdisabled
Ventilation after downloadlistoff
Integration time heat [min] [Ti]unsignedInt 5…250120
Proportional band heat [Bp]list1°C
Integration time cool [min] [Ti]unsignedInt 5…250120
Proportional band cool [Bp]list1°C
2nd stage heatinglistenabled
2nd stage heating telegramlist1 bit
Activation telegram 2nd stage heatinglisttelegram "1"
2nd stage coolinglistenabled
2nd stage cooling telegramlist1 bit
Activation telegram 2nd stage coolinglisttelegram "1"
Bandgaplist0°C
Proportional band [Bp]list2.0°C
Control typelistproportional
Integration time [min] [Ti]unsignedInt 5…250120
Integration time [min] [Ti]unsignedInt 5…255120
Control algorithmlistintegral proportional control PWM
Control algorithm 6 wayslistnothing
Enable valve whenlistcooling
Percentage 100% coollist0%
Percentage 0% coollist33%
Value to send for valve fully closedlist50%
Percentage 0% heatlist67%
Percentage 100% heatlist100%
Set the differential values of the bandlistno
Proportional band [Bp]list2°C
Regulation differential valve 0%list0°C
Regulation differential valve 100%list2.0°C
Activation telegramlisttelegram "1"
State after downloadlistenabled
Hysteresislist0.5°C
Upper setpoint valuelist+25°C
Telegram when value is above setpointliston
Telegram when value is below setpointlistoff
Telegram when probe is disabledlistoff
Cyclic sending time of telegramlistno cyclic send
Lower setpoint valuelist+20°C
Telegram when value is above setpointlistoff
Telegram when value is below setpointliston
Temperature sourcelistexternal probe
Temperature objectlistdisabled
Sensor codelistTS01A01ACC
Weight external probelist50%
External sensor calibration [0.1°C]signedInt -100…1000
KNX sensor calibration [0.1°C]signedInt -100…1000
Sending intervallistnever
Sending on variationlistnever
Surveillance time for KNX probe (0=disabled) [min]unsignedInt 0…25515
Logic functionlistdisabled
Logic delaylist0
Number of transmissions on outputlist1
Retransmission delaylist2 s
Value sent when 0 is receivedunsignedInt 0…2550
Value sent when 1 is receivedunsignedInt 0…255128
Byte valueunsignedInt 0…255128
Output bit when byte is receivedlist1
Output bit otherwiselist0
Threshold valueunsignedInt 0…255128
Output bit when input > thresholdlist1
Output bit when input <= thresholdlist0
Threshold valuefloat -671088…6707600
Threshold valuefloat -9223372036854776000…87622034350120370000
Dead band [0.1°C]unsignedInt 0…25520
Proportional band [Bp] [0.1°C]unsignedInt 0…25530
Proportional conversionlistbit to proportional
Lower limit valueunsignedInt 0…2550
Value to send for speed 1unsignedInt 0…25585
Limit value speed 1/2unsignedInt 0…25585
Value to send for speed 2unsignedInt 0…255170
Limit value speed 2/3unsignedInt 0…255170
Value to send for speed 3unsignedInt 0…255255
Bandgap [0.1°C]signedInt -128…1270
Altitude (tens of meters above sea level)unsignedInt 0…25550
Output typelistoff/on
Inverted controllistno
DPT Outputlist1 bit
DPT Input Alist1 bit
DPT Input Blist1 bit
DPT Input Clist1 bit
DPT Input Dlist1 bit
Logic expressiontext0
Logic versionlistfirst version
Presence Wait Timelist15 min
Cyclic Presence Send Timelistno cyclic send
Presence sensor OFF latency [s]unsignedInt 0…6310
Send welcome on unexpected presencelistdo not send
Global Enable state after downloadlistdisabled
Booked state after downloadlistnot booked
Absence with door open (deny=if door open presence is active)listallow
Local input type 1listdisabled
Contact type 1listcontact closed with door closed
Contact type 1listnormally open
Local input type 2listdisabled
Contact type 2listcontact closed with door closed
Contact type 2listnormally open
Local input type 3listdisabled
Contact type 3listcontact closed with door closed
Contact type 3listnormally open
Local input type 4listdisabled
Contact type 4listcontact closed with door closed
Contact type 4listnormally open
Remote input type 1listdisabled
Subordinate to Remote Inputs Enablelistnot subordinate
Remote input type 2listdisabled
Remote input type 3listdisabled
Remote input type 4listdisabled
Remote input type 5listdisabled
HVAC booked goodbyelistdo not send
HVAC non-booked goodbyelistdo not send
HVAC booked welcomelistdo not send
HVAC non-booked welcomelistdo not send
Send additional booked goodbyelistdo not send
Value additional booked goodbyeunsignedInt 0…2550
Send additional non-booked goodbyelistdo not send
Value additional non-booked goodbyeunsignedInt 0…2550
Send additional booked welcomelistdo not send
Value additional booked welcomeunsignedInt 0…2550
Send additional non-booked welcomelistdo not send
Value additional non-booked welcomeunsignedInt 0…2550

Version history

ApplicationApp noFingerprintFirst seenSizeFile
AD84C01KNX 1.1 latest$0608E96A2026-11-25500 KBDownload

About this file

This is the official ETS product database for the Eelectron AD84C01KNX Analog / Digital Module 8 Input / 4 led Output (AD84C01KNX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.