AD84C01KNX Analog / Digital Module 8 Input / 4 led Output AD84C01KNX
Eelectron · Order number AD84C01KNX · Input/Output Module › Module 8-Input 4-Output
Analog / Digital Module 8 Input / 4 led Output
Download .knxprod AD84C01KNX 1.1 · 500 KB
Product
| Manufacturer | Eelectron |
|---|---|
| Product name | AD84C01KNX Analog / Digital Module 8 Input / 4 led Output |
| Order number | AD84C01KNX |
| Product text | Analog / Digital Module 8 Input / 4 led Output |
| Hardware | AD84C01KNX |
| Medium | Twisted Pair |
| Bus current (mA) | 5 |
| Rail mounted | No |
| Registration | Certified · 2019-01-22 |
| Languages | fr-FR, it-IT, en-US, de-DE, es-ES, ru-RU |
| Catalog entry | M-006C_H-AD84C01KNX-1_HP-0608-11-E96A_CI-AD84C01KNX-2 |
| Fingerprint | E96A |
| SHA-256 | edcaefeab65005a47598b9684a3e7557aac126ee0ebebb7aba49425f4664db62 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: AD84C01KNX 1.1
| Application number | $0608 |
|---|---|
| Version | 1.1 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 2404 |
| Group objects | 1161 |
Group objects (1161)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | <LED 1> Command | Off/On | 1 Bit | 1.1 switch | CW |
| 1 | <LED 2> Command | Off/On | 1 Bit | 1.1 switch | CW |
| 2 | <LED 3> Command | Off/On | 1 Bit | 1.1 switch | CW |
| 3 | <LED 4> Command | Off/On | 1 Bit | 1.1 switch | CW |
| 4 | <Input 1> Counter | 4 Bytes | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 4 | <Input 1> RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 4 | <Input 1> Counter | 2 Bytes | 2 Bytes | 7.1 pulses | CRT |
| 4 | <Input 1> Counter | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 4 | <Input 1> Red | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 4 | <Input 1> Closure Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 4 | <Input 1> Closure Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 4 | <Input 1> Closure Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 4 | <Input 1> Closure - Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 4 | <Input 1> Closure - Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 4 | <Input 1> Closure - Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 4 | <Input 1> Short - Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 4 | <Input 1> Short - Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 4 | <Input 1> Short - Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 4 | <Input 1> Recall/Learn Scene | Scene | 1 Byte | 18.1 scene control | CRT |
| 4 | <Input 1> Sequence Command A 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 4 | <Input 1> Sequence Command A 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 4 | <Input 1> Sequence Command A HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 4 | <Input 1> Sequence Command A 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 4 | <Input 1> Sequence Command A 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 4 | <Input 1> Sequence Command A HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 4 | <Input 1> Closure Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 4 | <Input 1> Closure - Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 4 | <Input 1> Short - Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 4 | <Input 1> Dimming On/Off | Off/On | 1 Bit | 1.1 switch | CRWT |
| 4 | <Input 1> Object A | Off/On | 1 Bit | 1.1 switch | CRT |
| 4 | <Input 1> Shutter - Up/Down | Up/Down | 1 Bit | 1.8 up/down | CRWT |
| 4 | <Input 1> Sequence Command A Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 4 | <Input 1> Sequence Command A Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 4 | <Input 1> Make Up Room | Off/On | 1 Bit | 1.1 switch | CRT |
| 5 | <Input 1> Green | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 5 | <Input 1> Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 5 | <Input 1> Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 5 | <Input 1> Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 5 | <Input 1> Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 5 | <Input 1> Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 5 | <Input 1> Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 5 | <Input 1> Sequence Command B 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 5 | <Input 1> Sequence Command B 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 5 | <Input 1> Sequence Command B HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 5 | <Input 1> Sequence Command B 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 5 | <Input 1> Sequence Command B 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 5 | <Input 1> Sequence Command B HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 5 | <Input 1> Loop Value Output | Loop Value Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 5 | <Input 1> Dimming Control | Brighter/Darker | 4 Bit | 3.7 dimming control | CRT |
| 5 | <Input 1> Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 5 | <Input 1> Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 5 | <Input 1> Object B | Off/On | 1 Bit | 1.1 switch | CRT |
| 5 | <Input 1> Shutter - Step/Stop | Step/Stop | 1 Bit | 1.7 step | CRT |
| 5 | <Input 1> Sequence Command B Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 5 | <Input 1> Sequence Command B Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 5 | <Input 1> Send Learn Scene Trigger | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 5 | <Input 1> Reset Counter | Reset | 1 Bit | 1.15 reset | CW |
| 5 | <Input 1> Do Not Disturb | Off/On | 1 Bit | 1.1 switch | CRT |
| 6 | <Input 1> Additional Object RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 6 | <Input 1> Blue | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 6 | <Input 1> Sequence Command C 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 6 | <Input 1> Sequence Command C 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 6 | <Input 1> Sequence Command C HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 6 | <Input 1> Sequence Command C 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 6 | <Input 1> Sequence Command C 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 6 | <Input 1> Sequence Command C HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 6 | <Input 1> Out Overflow Counter | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 6 | <Input 1> Out Overflow Counter | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 6 | <Input 1> Out Overflow Counter | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 6 | <Input 1> Loop Value Feedback | Loop Value Feedback | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 6 | <Input 1> Sequence Command C Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 6 | <Input 1> Sequence Command C Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 6 | <Input 1> Feedback | Off/On | 1 Bit | 1.1 switch | CW |
| 6 | <Input 1> Feedback | Up/Down | 1 Bit | 1.8 up/down | CW |
| 6 | <Input 1> Object C | Off/On | 1 Bit | 1.1 switch | CRT |
| 6 | <Input 1> Out Overflow Counter | Off/On | 1 Bit | 1.1 switch | CRT |
| 7 | <Input 1> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 8 | <Input 2> Counter | 4 Bytes | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 8 | <Input 2> RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 8 | <Input 2> Counter | 2 Bytes | 2 Bytes | 7.1 pulses | CRT |
| 8 | <Input 2> Counter | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 8 | <Input 2> Red | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 8 | <Input 2> Closure Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 8 | <Input 2> Closure Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | <Input 2> Closure Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 8 | <Input 2> Closure - Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 8 | <Input 2> Closure - Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | <Input 2> Closure - Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 8 | <Input 2> Short - Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 8 | <Input 2> Short - Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | <Input 2> Short - Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 8 | <Input 2> Recall/Learn Scene | Scene | 1 Byte | 18.1 scene control | CRT |
| 8 | <Input 2> Sequence Command A 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 8 | <Input 2> Sequence Command A 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | <Input 2> Sequence Command A HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 8 | <Input 2> Sequence Command A 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 8 | <Input 2> Sequence Command A 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 8 | <Input 2> Sequence Command A HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 8 | <Input 2> Closure Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 8 | <Input 2> Closure - Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 8 | <Input 2> Short - Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 8 | <Input 2> Dimming On/Off | Off/On | 1 Bit | 1.1 switch | CRWT |
| 8 | <Input 2> Object A | Off/On | 1 Bit | 1.1 switch | CRT |
| 8 | <Input 2> Shutter - Up/Down | Up/Down | 1 Bit | 1.8 up/down | CRWT |
| 8 | <Input 2> Sequence Command A Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 8 | <Input 2> Sequence Command A Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 8 | <Input 2> Make Up Room | Off/On | 1 Bit | 1.1 switch | CRT |
| 9 | <Input 2> Green | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 9 | <Input 2> Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 9 | <Input 2> Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 9 | <Input 2> Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 9 | <Input 2> Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 9 | <Input 2> Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 9 | <Input 2> Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 9 | <Input 2> Sequence Command B 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 9 | <Input 2> Sequence Command B 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 9 | <Input 2> Sequence Command B HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 9 | <Input 2> Sequence Command B 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 9 | <Input 2> Sequence Command B 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 9 | <Input 2> Sequence Command B HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 9 | <Input 2> Loop Value Output | Loop Value Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 9 | <Input 2> Dimming Control | Brighter/Darker | 4 Bit | 3.7 dimming control | CRT |
| 9 | <Input 2> Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 9 | <Input 2> Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 9 | <Input 2> Object B | Off/On | 1 Bit | 1.1 switch | CRT |
| 9 | <Input 2> Shutter - Step/Stop | Step/Stop | 1 Bit | 1.7 step | CRT |
| 9 | <Input 2> Sequence Command B Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 9 | <Input 2> Sequence Command B Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 9 | <Input 2> Send Learn Scene Trigger | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 9 | <Input 2> Reset Counter | Reset | 1 Bit | 1.15 reset | CW |
| 9 | <Input 2> Do Not Disturb | Off/On | 1 Bit | 1.1 switch | CRT |
| 10 | <Input 2> Additional Object RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 10 | <Input 2> Blue | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 10 | <Input 2> Sequence Command C 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 10 | <Input 2> Sequence Command C 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 10 | <Input 2> Sequence Command C HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 10 | <Input 2> Sequence Command C 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 10 | <Input 2> Sequence Command C 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 10 | <Input 2> Sequence Command C HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 10 | <Input 2> Out Overflow Counter | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 10 | <Input 2> Out Overflow Counter | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 10 | <Input 2> Out Overflow Counter | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 10 | <Input 2> Loop Value Feedback | Loop Value Feedback | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 10 | <Input 2> Sequence Command C Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 10 | <Input 2> Sequence Command C Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 10 | <Input 2> Feedback | Off/On | 1 Bit | 1.1 switch | CW |
| 10 | <Input 2> Feedback | Up/Down | 1 Bit | 1.8 up/down | CW |
| 10 | <Input 2> Object C | Off/On | 1 Bit | 1.1 switch | CRT |
| 10 | <Input 2> Out Overflow Counter | Off/On | 1 Bit | 1.1 switch | CRT |
| 11 | <Input 2> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 12 | <Input 3> Counter | 4 Bytes | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 12 | <Input 3> RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 12 | <Input 3> Counter | 2 Bytes | 2 Bytes | 7.1 pulses | CRT |
| 12 | <Input 3> Counter | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 12 | <Input 3> Red | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 12 | <Input 3> Closure Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 12 | <Input 3> Closure Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 12 | <Input 3> Closure Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 12 | <Input 3> Closure - Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 12 | <Input 3> Closure - Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 12 | <Input 3> Closure - Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 12 | <Input 3> Short - Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 12 | <Input 3> Short - Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 12 | <Input 3> Short - Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 12 | <Input 3> Recall/Learn Scene | Scene | 1 Byte | 18.1 scene control | CRT |
| 12 | <Input 3> Sequence Command A 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 12 | <Input 3> Sequence Command A 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 12 | <Input 3> Sequence Command A HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 12 | <Input 3> Sequence Command A 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 12 | <Input 3> Sequence Command A 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 12 | <Input 3> Sequence Command A HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 12 | <Input 3> Closure Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 12 | <Input 3> Closure - Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 12 | <Input 3> Short - Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 12 | <Input 3> Dimming On/Off | Off/On | 1 Bit | 1.1 switch | CRWT |
| 12 | <Input 3> Object A | Off/On | 1 Bit | 1.1 switch | CRT |
| 12 | <Input 3> Shutter - Up/Down | Up/Down | 1 Bit | 1.8 up/down | CRWT |
| 12 | <Input 3> Sequence Command A Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 12 | <Input 3> Sequence Command A Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 12 | <Input 3> Make Up Room | Off/On | 1 Bit | 1.1 switch | CRT |
| 13 | <Input 3> Green | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 13 | <Input 3> Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 13 | <Input 3> Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 13 | <Input 3> Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 13 | <Input 3> Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 13 | <Input 3> Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 13 | <Input 3> Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 13 | <Input 3> Sequence Command B 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 13 | <Input 3> Sequence Command B 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 13 | <Input 3> Sequence Command B HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 13 | <Input 3> Sequence Command B 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 13 | <Input 3> Sequence Command B 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 13 | <Input 3> Sequence Command B HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 13 | <Input 3> Loop Value Output | Loop Value Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 13 | <Input 3> Dimming Control | Brighter/Darker | 4 Bit | 3.7 dimming control | CRT |
| 13 | <Input 3> Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 13 | <Input 3> Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 13 | <Input 3> Object B | Off/On | 1 Bit | 1.1 switch | CRT |
| 13 | <Input 3> Shutter - Step/Stop | Step/Stop | 1 Bit | 1.7 step | CRT |
| 13 | <Input 3> Sequence Command B Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 13 | <Input 3> Sequence Command B Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 13 | <Input 3> Send Learn Scene Trigger | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 13 | <Input 3> Reset Counter | Reset | 1 Bit | 1.15 reset | CW |
| 13 | <Input 3> Do Not Disturb | Off/On | 1 Bit | 1.1 switch | CRT |
| 14 | <Input 3> Additional Object RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 14 | <Input 3> Blue | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 14 | <Input 3> Sequence Command C 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 14 | <Input 3> Sequence Command C 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 14 | <Input 3> Sequence Command C HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 14 | <Input 3> Sequence Command C 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 14 | <Input 3> Sequence Command C 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 14 | <Input 3> Sequence Command C HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 14 | <Input 3> Out Overflow Counter | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 14 | <Input 3> Out Overflow Counter | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 14 | <Input 3> Out Overflow Counter | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 14 | <Input 3> Loop Value Feedback | Loop Value Feedback | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 14 | <Input 3> Sequence Command C Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 14 | <Input 3> Sequence Command C Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 14 | <Input 3> Feedback | Off/On | 1 Bit | 1.1 switch | CW |
| 14 | <Input 3> Feedback | Up/Down | 1 Bit | 1.8 up/down | CW |
| 14 | <Input 3> Object C | Off/On | 1 Bit | 1.1 switch | CRT |
| 14 | <Input 3> Out Overflow Counter | Off/On | 1 Bit | 1.1 switch | CRT |
| 15 | <Input 3> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 16 | <Input 4> Counter | 4 Bytes | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 16 | <Input 4> RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 16 | <Input 4> Counter | 2 Bytes | 2 Bytes | 7.1 pulses | CRT |
| 16 | <Input 4> Counter | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 16 | <Input 4> Red | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 16 | <Input 4> Closure Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 16 | <Input 4> Closure Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | <Input 4> Closure Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 16 | <Input 4> Closure - Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 16 | <Input 4> Closure - Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | <Input 4> Closure - Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 16 | <Input 4> Short - Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 16 | <Input 4> Short - Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | <Input 4> Short - Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 16 | <Input 4> Recall/Learn Scene | Scene | 1 Byte | 18.1 scene control | CRT |
| 16 | <Input 4> Sequence Command A 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 16 | <Input 4> Sequence Command A 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | <Input 4> Sequence Command A HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 16 | <Input 4> Sequence Command A 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 16 | <Input 4> Sequence Command A 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | <Input 4> Sequence Command A HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 16 | <Input 4> Closure Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 16 | <Input 4> Closure - Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 16 | <Input 4> Short - Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 16 | <Input 4> Dimming On/Off | Off/On | 1 Bit | 1.1 switch | CRWT |
| 16 | <Input 4> Object A | Off/On | 1 Bit | 1.1 switch | CRT |
| 16 | <Input 4> Shutter - Up/Down | Up/Down | 1 Bit | 1.8 up/down | CRWT |
| 16 | <Input 4> Sequence Command A Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 16 | <Input 4> Sequence Command A Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 16 | <Input 4> Make Up Room | Off/On | 1 Bit | 1.1 switch | CRT |
| 17 | <Input 4> Green | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 17 | <Input 4> Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 17 | <Input 4> Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 17 | <Input 4> Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | <Input 4> Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 17 | <Input 4> Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 17 | <Input 4> Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | <Input 4> Sequence Command B 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 17 | <Input 4> Sequence Command B 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 17 | <Input 4> Sequence Command B HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | <Input 4> Sequence Command B 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 17 | <Input 4> Sequence Command B 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 17 | <Input 4> Sequence Command B HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 17 | <Input 4> Loop Value Output | Loop Value Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 17 | <Input 4> Dimming Control | Brighter/Darker | 4 Bit | 3.7 dimming control | CRT |
| 17 | <Input 4> Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 17 | <Input 4> Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 17 | <Input 4> Object B | Off/On | 1 Bit | 1.1 switch | CRT |
| 17 | <Input 4> Shutter - Step/Stop | Step/Stop | 1 Bit | 1.7 step | CRT |
| 17 | <Input 4> Sequence Command B Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 17 | <Input 4> Sequence Command B Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 17 | <Input 4> Send Learn Scene Trigger | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 17 | <Input 4> Reset Counter | Reset | 1 Bit | 1.15 reset | CW |
| 17 | <Input 4> Do Not Disturb | Off/On | 1 Bit | 1.1 switch | CRT |
| 18 | <Input 4> Additional Object RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 18 | <Input 4> Blue | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 18 | <Input 4> Sequence Command C 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 18 | <Input 4> Sequence Command C 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | <Input 4> Sequence Command C HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 18 | <Input 4> Sequence Command C 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 18 | <Input 4> Sequence Command C 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | <Input 4> Sequence Command C HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 18 | <Input 4> Out Overflow Counter | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 18 | <Input 4> Out Overflow Counter | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | <Input 4> Out Overflow Counter | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 18 | <Input 4> Loop Value Feedback | Loop Value Feedback | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 18 | <Input 4> Sequence Command C Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 18 | <Input 4> Sequence Command C Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 18 | <Input 4> Feedback | Off/On | 1 Bit | 1.1 switch | CW |
| 18 | <Input 4> Feedback | Up/Down | 1 Bit | 1.8 up/down | CW |
| 18 | <Input 4> Object C | Off/On | 1 Bit | 1.1 switch | CRT |
| 18 | <Input 4> Out Overflow Counter | Off/On | 1 Bit | 1.1 switch | CRT |
| 19 | <Input 4> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 20 | <Input 5> RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 20 | <Input 5> Red | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 20 | <Input 5> Closure Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 20 | <Input 5> Closure Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | <Input 5> Closure Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 20 | <Input 5> Closure - Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 20 | <Input 5> Closure - Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | <Input 5> Closure - Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 20 | <Input 5> Short - Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 20 | <Input 5> Short - Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | <Input 5> Short - Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 20 | <Input 5> Recall/Learn Scene | Scene | 1 Byte | 18.1 scene control | CRT |
| 20 | <Input 5> Sequence Command A 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 20 | <Input 5> Sequence Command A 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | <Input 5> Sequence Command A HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 20 | <Input 5> Sequence Command A 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 20 | <Input 5> Sequence Command A 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 20 | <Input 5> Sequence Command A HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 20 | <Temperature 5> Alarm | Disable/Enable | 1 Bit | 1.1 switch | CRT |
| 20 | <Input 5> Closure Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 20 | <Input 5> Closure - Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 20 | <Input 5> Short - Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 20 | <Input 5> Dimming On/Off | Off/On | 1 Bit | 1.1 switch | CRWT |
| 20 | <Input 5> Object A | Off/On | 1 Bit | 1.1 switch | CRT |
| 20 | <Input 5> Shutter - Up/Down | Up/Down | 1 Bit | 1.8 up/down | CRWT |
| 20 | <Input 5> Sequence Command A Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 20 | <Input 5> Sequence Command A Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 20 | <Input 5> Make Up Room | Off/On | 1 Bit | 1.1 switch | CRT |
| 21 | <Temperature 5> Actual Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 21 | <Input 5> Green | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 21 | <Input 5> Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 21 | <Input 5> Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 21 | <Input 5> Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 21 | <Input 5> Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 21 | <Input 5> Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 21 | <Input 5> Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 21 | <Input 5> Sequence Command B 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 21 | <Input 5> Sequence Command B 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 21 | <Input 5> Sequence Command B HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 21 | <Input 5> Sequence Command B 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 21 | <Input 5> Sequence Command B 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 21 | <Input 5> Sequence Command B HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 21 | <Input 5> Loop Value Output | Loop Value Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 21 | <Input 5> Dimming Control | Brighter/Darker | 4 Bit | 3.7 dimming control | CRT |
| 21 | <Input 5> Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 21 | <Input 5> Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 21 | <Input 5> Object B | Off/On | 1 Bit | 1.1 switch | CRT |
| 21 | <Input 5> Shutter - Step/Stop | Step/Stop | 1 Bit | 1.7 step | CRT |
| 21 | <Input 5> Sequence Command B Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 21 | <Input 5> Sequence Command B Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 21 | <Input 5> Send Learn Scene Trigger | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 21 | <Input 5> Do Not Disturb | Off/On | 1 Bit | 1.1 switch | CRT |
| 22 | <Input 5> Additional Object RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 22 | <Temperature 5> KNX Probe Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 22 | <Input 5> Blue | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 22 | <Input 5> Sequence Command C 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 22 | <Input 5> Sequence Command C 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 22 | <Input 5> Sequence Command C HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 22 | <Input 5> Sequence Command C 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 22 | <Input 5> Sequence Command C 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 22 | <Input 5> Sequence Command C HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 22 | <Input 5> Loop Value Feedback | Loop Value Feedback | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 22 | <Input 5> Sequence Command C Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 22 | <Input 5> Sequence Command C Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 22 | <Input 5> Feedback | Off/On | 1 Bit | 1.1 switch | CW |
| 22 | <Input 5> Feedback | Up/Down | 1 Bit | 1.8 up/down | CW |
| 22 | <Input 5> Object C | Off/On | 1 Bit | 1.1 switch | CRT |
| 23 | <Input 5> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 23 | <Thermostat 5> Heat/Cool Mode | Heat/Cool | 1 Bit | 1.100 heating/cooling | CW |
| 23 | <Thermostat 5> Heat/Cool Mode | Heat/Cool | 1 Bit | 1.100 heating/cooling | CRT |
| 23 | <T.Sensor 5> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 24 | <T.Sensor 5> Setpoint Upper | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 24 | <Thermostat 5> Window Contact | Close/Open | 1 Bit | 1.19 window/door | CW |
| 25 | <Thermostat 5> Comfort Mode | Off/On | 1 Bit | 1.1 switch | CW |
| 25 | <T.Sensor 5> Telegram Upper | Off/On | 1 Bit | 1.1 switch | CRT |
| 26 | <T.Sensor 5> Setpoint Lower | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 26 | <Thermostat 5> HVAC Mode | Comf/Standby/Eco/B.protection | 1 Byte | 20.102 HVAC mode | CW |
| 27 | <Thermostat 5> Actual Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 27 | <T.Sensor 5> Telegram Lower | Off/On | 1 Bit | 1.1 switch | CRT |
| 28 | <Thermostat 5> Setpoint Adjustment | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 28 | <Thermostat 5> Setpoint Adjustment | Value °C | 1 Bit | 1.7 step | CW |
| 29 | <Thermostat 5> Base Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 29 | <Thermostat 5> SP Economy Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 29 | <Thermostat 5> SP Economy | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 30 | <Thermostat 5> SP Standby Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 30 | <Thermostat 5> SP Standby | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 31 | <Thermostat 5> SP Comfort Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 31 | <Thermostat 5> SP Comfort | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 32 | <Thermostat 5> SP Economy Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 33 | <Thermostat 5> SP Standby Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 34 | <Thermostat 5> SP Comfort Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 35 | <Thermostat 5> Heating | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 35 | <Thermostat 5> Heating | Off/On | 1 Bit | 1.1 switch | CRT |
| 35 | <Fan Coil 5> Heating/Cooling Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 35 | <Fan Coil 5> Heating Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 36 | <Thermostat 5> Cooling | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 36 | <Thermostat 5> Cooling | Off/On | 1 Bit | 1.1 switch | CRT |
| 36 | <Fan Coil 5> Cooling Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 37 | <Thermostat 5> 0-100% 2nd Stage Heating | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 37 | <Thermostat 5> Off/On 2nd Stage Heating | Off/On | 1 Bit | 1.1 switch | CRT |
| 38 | <Thermostat 5> 0-100% 2nd Stage Cooling | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 38 | <Thermostat 5> Off/On 2nd Stage Cooling | Off/On | 1 Bit | 1.1 switch | CRT |
| 39 | <Fan Coil 5> Continuous Control % | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 39 | <Fan Coil 5> Speed 1 | Off/On | 1 Bit | 1.1 switch | CRT |
| 40 | <Fan Coil 5> Speed 2 | Off/On | 1 Bit | 1.1 switch | CRT |
| 41 | <Fan Coil 5> Speed 3 | Off/On | 1 Bit | 1.1 switch | CRT |
| 42 | <Fan Coil 5> Set Man/Auto Mode | Manual (0) / Auto (1) | 1 Bit | 1.1 switch | CW |
| 43 | <Fan Coil 5> Force Speed Control in Man Mode | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CW |
| 43 | <Fan Coil 5> Force Value in Man Mode Speed 1 | Off/On | 1 Bit | 1.1 switch | CW |
| 44 | <Fan Coil 5> Force Value in Man Mode Speed 2 | Off/On | 1 Bit | 1.1 switch | CW |
| 45 | <Fan Coil 5> Force Value in Man Mode Speed 3 | Off/On | 1 Bit | 1.1 switch | CW |
| 46 | <Thermostat 5> OFF Thermostat | Off/On | 1 Bit | 1.1 switch | CRWT |
| 47 | <Fan Coil 5> Ventilation Off/On | Off/On | 1 Bit | 1.1 switch | CW |
| 48 | <Additional Valve 5> Percentage | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 48 | <Additional Valve 5> Valve 6 Ways | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 48 | <Additional Valve 5> PWM | Off/On | 1 Bit | 1.1 switch | CRT |
| 49 | <Input 6> RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 49 | <Input 6> Red | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 49 | <Input 6> Closure Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 49 | <Input 6> Closure Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | <Input 6> Closure Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 49 | <Input 6> Closure - Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 49 | <Input 6> Closure - Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | <Input 6> Closure - Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 49 | <Input 6> Short - Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 49 | <Input 6> Short - Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | <Input 6> Short - Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 49 | <Input 6> Recall/Learn Scene | Scene | 1 Byte | 18.1 scene control | CRT |
| 49 | <Input 6> Sequence Command A 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 49 | <Input 6> Sequence Command A 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | <Input 6> Sequence Command A HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 49 | <Input 6> Sequence Command A 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 49 | <Input 6> Sequence Command A 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 49 | <Input 6> Sequence Command A HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 49 | <Temperature 6> Alarm | Disable/Enable | 1 Bit | 1.1 switch | CRT |
| 49 | <Input 6> Closure Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 49 | <Input 6> Closure - Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 49 | <Input 6> Short - Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 49 | <Input 6> Dimming On/Off | Off/On | 1 Bit | 1.1 switch | CRWT |
| 49 | <Input 6> Object A | Off/On | 1 Bit | 1.1 switch | CRT |
| 49 | <Input 6> Shutter - Up/Down | Up/Down | 1 Bit | 1.8 up/down | CRWT |
| 49 | <Input 6> Sequence Command A Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 49 | <Input 6> Sequence Command A Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 49 | <Input 6> Make Up Room | Off/On | 1 Bit | 1.1 switch | CRT |
| 50 | <Temperature 6> Actual Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 50 | <Input 6> Green | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 50 | <Input 6> Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 50 | <Input 6> Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 50 | <Input 6> Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 50 | <Input 6> Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 50 | <Input 6> Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 50 | <Input 6> Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 50 | <Input 6> Sequence Command B 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 50 | <Input 6> Sequence Command B 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 50 | <Input 6> Sequence Command B HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 50 | <Input 6> Sequence Command B 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 50 | <Input 6> Sequence Command B 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 50 | <Input 6> Sequence Command B HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 50 | <Input 6> Loop Value Output | Loop Value Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 50 | <Input 6> Dimming Control | Brighter/Darker | 4 Bit | 3.7 dimming control | CRT |
| 50 | <Input 6> Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 50 | <Input 6> Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 50 | <Input 6> Object B | Off/On | 1 Bit | 1.1 switch | CRT |
| 50 | <Input 6> Shutter - Step/Stop | Step/Stop | 1 Bit | 1.7 step | CRT |
| 50 | <Input 6> Sequence Command B Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 50 | <Input 6> Sequence Command B Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 50 | <Input 6> Send Learn Scene Trigger | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 50 | <Input 6> Do Not Disturb | Off/On | 1 Bit | 1.1 switch | CRT |
| 51 | <Input 6> Additional Object RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 51 | <Temperature 6> KNX Probe Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 51 | <Input 6> Blue | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 51 | <Input 6> Sequence Command C 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 51 | <Input 6> Sequence Command C 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 51 | <Input 6> Sequence Command C HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 51 | <Input 6> Sequence Command C 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 51 | <Input 6> Sequence Command C 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 51 | <Input 6> Sequence Command C HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 51 | <Input 6> Loop Value Feedback | Loop Value Feedback | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 51 | <Input 6> Sequence Command C Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 51 | <Input 6> Sequence Command C Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 51 | <Input 6> Feedback | Off/On | 1 Bit | 1.1 switch | CW |
| 51 | <Input 6> Feedback | Up/Down | 1 Bit | 1.8 up/down | CW |
| 51 | <Input 6> Object C | Off/On | 1 Bit | 1.1 switch | CRT |
| 52 | <Input 6> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 52 | <Thermostat 6> Heat/Cool Mode | Heat/Cool | 1 Bit | 1.100 heating/cooling | CW |
| 52 | <Thermostat 6> Heat/Cool Mode | Heat/Cool | 1 Bit | 1.100 heating/cooling | CRT |
| 52 | <T.Sensor 6> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 53 | <T.Sensor 6> Setpoint Upper | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 53 | <Thermostat 6> Window Contact | Close/Open | 1 Bit | 1.19 window/door | CW |
| 54 | <Thermostat 6> Comfort Mode | Off/On | 1 Bit | 1.1 switch | CW |
| 54 | <T.Sensor 6> Telegram Upper | Off/On | 1 Bit | 1.1 switch | CRT |
| 55 | <T.Sensor 6> Setpoint Lower | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 55 | <Thermostat 6> HVAC Mode | Comf/Standby/Eco/B.protection | 1 Byte | 20.102 HVAC mode | CW |
| 56 | <Thermostat 6> Actual Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 56 | <T.Sensor 6> Telegram Lower | Off/On | 1 Bit | 1.1 switch | CRT |
| 57 | <Thermostat 6> Setpoint Adjustment | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 57 | <Thermostat 6> Setpoint Adjustment | Value °C | 1 Bit | 1.7 step | CW |
| 58 | <Thermostat 6> Base Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 58 | <Thermostat 6> SP Economy Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 58 | <Thermostat 6> SP Economy | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 59 | <Thermostat 6> SP Standby Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 59 | <Thermostat 6> SP Standby | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 60 | <Thermostat 6> SP Comfort Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 60 | <Thermostat 6> SP Comfort | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 61 | <Thermostat 6> SP Economy Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 62 | <Thermostat 6> SP Standby Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 63 | <Thermostat 6> SP Comfort Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 64 | <Thermostat 6> Heating | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 64 | <Thermostat 6> Heating | Off/On | 1 Bit | 1.1 switch | CRT |
| 64 | <Fan Coil 6> Heating/Cooling Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 64 | <Fan Coil 6> Heating Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 65 | <Thermostat 6> Cooling | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 65 | <Thermostat 6> Cooling | Off/On | 1 Bit | 1.1 switch | CRT |
| 65 | <Fan Coil 6> Cooling Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 66 | <Thermostat 6> 0-100% 2nd Stage Heating | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 66 | <Thermostat 6> Off/On 2nd Stage Heating | Off/On | 1 Bit | 1.1 switch | CRT |
| 67 | <Thermostat 6> 0-100% 2nd Stage Cooling | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 67 | <Thermostat 6> Off/On 2nd Stage Cooling | Off/On | 1 Bit | 1.1 switch | CRT |
| 68 | <Fan Coil 6> Continuous Control % | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 68 | <Fan Coil 6> Speed 1 | Off/On | 1 Bit | 1.1 switch | CRT |
| 69 | <Fan Coil 6> Speed 2 | Off/On | 1 Bit | 1.1 switch | CRT |
| 70 | <Fan Coil 6> Speed 3 | Off/On | 1 Bit | 1.1 switch | CRT |
| 71 | <Fan Coil 6> Set Man/Auto Mode | Manual (0) / Auto (1) | 1 Bit | 1.1 switch | CW |
| 72 | <Fan Coil 6> Force Speed Control in Man Mode | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CW |
| 72 | <Fan Coil 6> Force Value in Man Mode Speed 1 | Off/On | 1 Bit | 1.1 switch | CW |
| 73 | <Fan Coil 6> Force Value in Man Mode Speed 2 | Off/On | 1 Bit | 1.1 switch | CW |
| 74 | <Fan Coil 6> Force Value in Man Mode Speed 3 | Off/On | 1 Bit | 1.1 switch | CW |
| 75 | <Thermostat 6> OFF Thermostat | Off/On | 1 Bit | 1.1 switch | CRWT |
| 76 | <Fan Coil 6> Ventilation Off/On | Off/On | 1 Bit | 1.1 switch | CW |
| 77 | <Additional Valve 6> Percentage | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 77 | <Additional Valve 6> Valve 6 Ways | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 77 | <Additional Valve 6> PWM | Off/On | 1 Bit | 1.1 switch | CRT |
| 78 | <Input 7> RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 78 | <Input 7> Red | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 78 | <Input 7> Closure Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 78 | <Input 7> Closure Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 78 | <Input 7> Closure Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 78 | <Input 7> Closure - Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 78 | <Input 7> Closure - Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 78 | <Input 7> Closure - Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 78 | <Input 7> Short - Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 78 | <Input 7> Short - Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 78 | <Input 7> Short - Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 78 | <Input 7> Recall/Learn Scene | Scene | 1 Byte | 18.1 scene control | CRT |
| 78 | <Input 7> Sequence Command A 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 78 | <Input 7> Sequence Command A 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 78 | <Input 7> Sequence Command A HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 78 | <Input 7> Sequence Command A 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 78 | <Input 7> Sequence Command A 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 78 | <Input 7> Sequence Command A HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 78 | <Temperature 7> Alarm | Disable/Enable | 1 Bit | 1.1 switch | CRT |
| 78 | <Input 7> Closure Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 78 | <Input 7> Closure - Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 78 | <Input 7> Short - Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 78 | <Input 7> Dimming On/Off | Off/On | 1 Bit | 1.1 switch | CRWT |
| 78 | <Input 7> Object A | Off/On | 1 Bit | 1.1 switch | CRT |
| 78 | <Input 7> Shutter - Up/Down | Up/Down | 1 Bit | 1.8 up/down | CRWT |
| 78 | <Input 7> Sequence Command A Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 78 | <Input 7> Sequence Command A Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 78 | <Input 7> Make Up Room | Off/On | 1 Bit | 1.1 switch | CRT |
| 79 | <Temperature 7> Actual Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 79 | <Input 7> Green | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 79 | <Input 7> Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 79 | <Input 7> Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 79 | <Input 7> Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 79 | <Input 7> Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 79 | <Input 7> Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 79 | <Input 7> Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 79 | <Input 7> Sequence Command B 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 79 | <Input 7> Sequence Command B 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 79 | <Input 7> Sequence Command B HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 79 | <Input 7> Sequence Command B 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 79 | <Input 7> Sequence Command B 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 79 | <Input 7> Sequence Command B HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 79 | <Input 7> Loop Value Output | Loop Value Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 79 | <Input 7> Dimming Control | Brighter/Darker | 4 Bit | 3.7 dimming control | CRT |
| 79 | <Input 7> Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 79 | <Input 7> Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 79 | <Input 7> Object B | Off/On | 1 Bit | 1.1 switch | CRT |
| 79 | <Input 7> Shutter - Step/Stop | Step/Stop | 1 Bit | 1.7 step | CRT |
| 79 | <Input 7> Sequence Command B Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 79 | <Input 7> Sequence Command B Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 79 | <Input 7> Send Learn Scene Trigger | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 79 | <Input 7> Do Not Disturb | Off/On | 1 Bit | 1.1 switch | CRT |
| 80 | <Input 7> Additional Object RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 80 | <Temperature 7> KNX Probe Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 80 | <Input 7> Blue | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 80 | <Input 7> Sequence Command C 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 80 | <Input 7> Sequence Command C 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 80 | <Input 7> Sequence Command C HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 80 | <Input 7> Sequence Command C 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 80 | <Input 7> Sequence Command C 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 80 | <Input 7> Sequence Command C HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 80 | <Input 7> Loop Value Feedback | Loop Value Feedback | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 80 | <Input 7> Sequence Command C Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 80 | <Input 7> Sequence Command C Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 80 | <Input 7> Feedback | Off/On | 1 Bit | 1.1 switch | CW |
| 80 | <Input 7> Feedback | Up/Down | 1 Bit | 1.8 up/down | CW |
| 80 | <Input 7> Object C | Off/On | 1 Bit | 1.1 switch | CRT |
| 81 | <Input 7> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 81 | <Thermostat 7> Heat/Cool Mode | Heat/Cool | 1 Bit | 1.100 heating/cooling | CW |
| 81 | <Thermostat 7> Heat/Cool Mode | Heat/Cool | 1 Bit | 1.100 heating/cooling | CRT |
| 81 | <T.Sensor 7> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 82 | <T.Sensor 7> Setpoint Upper | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 82 | <Thermostat 7> Window Contact | Close/Open | 1 Bit | 1.19 window/door | CW |
| 83 | <Thermostat 7> Comfort Mode | Off/On | 1 Bit | 1.1 switch | CW |
| 83 | <T.Sensor 7> Telegram Upper | Off/On | 1 Bit | 1.1 switch | CRT |
| 84 | <T.Sensor 7> Setpoint Lower | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 84 | <Thermostat 7> HVAC Mode | Comf/Standby/Eco/B.protection | 1 Byte | 20.102 HVAC mode | CW |
| 85 | <Thermostat 7> Actual Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 85 | <T.Sensor 7> Telegram Lower | Off/On | 1 Bit | 1.1 switch | CRT |
| 86 | <Thermostat 7> Setpoint Adjustment | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 86 | <Thermostat 7> Setpoint Adjustment | Value °C | 1 Bit | 1.7 step | CW |
| 87 | <Thermostat 7> Base Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 87 | <Thermostat 7> SP Economy Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 87 | <Thermostat 7> SP Economy | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 88 | <Thermostat 7> SP Standby Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 88 | <Thermostat 7> SP Standby | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 89 | <Thermostat 7> SP Comfort Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 89 | <Thermostat 7> SP Comfort | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 90 | <Thermostat 7> SP Economy Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 91 | <Thermostat 7> SP Standby Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 92 | <Thermostat 7> SP Comfort Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 93 | <Thermostat 7> Heating | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 93 | <Thermostat 7> Heating | Off/On | 1 Bit | 1.1 switch | CRT |
| 93 | <Fan Coil 7> Heating/Cooling Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 93 | <Fan Coil 7> Heating Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 94 | <Thermostat 7> Cooling | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 94 | <Thermostat 7> Cooling | Off/On | 1 Bit | 1.1 switch | CRT |
| 94 | <Fan Coil 7> Cooling Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 95 | <Thermostat 7> 0-100% 2nd Stage Heating | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 95 | <Thermostat 7> Off/On 2nd Stage Heating | Off/On | 1 Bit | 1.1 switch | CRT |
| 96 | <Thermostat 7> 0-100% 2nd Stage Cooling | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 96 | <Thermostat 7> Off/On 2nd Stage Cooling | Off/On | 1 Bit | 1.1 switch | CRT |
| 97 | <Fan Coil 7> Continuous Control % | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 97 | <Fan Coil 7> Speed 1 | Off/On | 1 Bit | 1.1 switch | CRT |
| 98 | <Fan Coil 7> Speed 2 | Off/On | 1 Bit | 1.1 switch | CRT |
| 99 | <Fan Coil 7> Speed 3 | Off/On | 1 Bit | 1.1 switch | CRT |
| 100 | <Fan Coil 7> Set Man/Auto Mode | Manual (0) / Auto (1) | 1 Bit | 1.1 switch | CW |
| 101 | <Fan Coil 7> Force Speed Control in Man Mode | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CW |
| 101 | <Fan Coil 7> Force Value in Man Mode Speed 1 | Off/On | 1 Bit | 1.1 switch | CW |
| 102 | <Fan Coil 7> Force Value in Man Mode Speed 2 | Off/On | 1 Bit | 1.1 switch | CW |
| 103 | <Fan Coil 7> Force Value in Man Mode Speed 3 | Off/On | 1 Bit | 1.1 switch | CW |
| 104 | <Thermostat 7> OFF Thermostat | Off/On | 1 Bit | 1.1 switch | CRWT |
| 105 | <Fan Coil 7> Ventilation Off/On | Off/On | 1 Bit | 1.1 switch | CW |
| 106 | <Additional Valve 7> Percentage | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 106 | <Additional Valve 7> Valve 6 Ways | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 106 | <Additional Valve 7> PWM | Off/On | 1 Bit | 1.1 switch | CRT |
| 107 | <Input 8> RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 107 | <Input 8> Red | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 107 | <Input 8> Closure Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 107 | <Input 8> Closure Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 107 | <Input 8> Closure Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 107 | <Input 8> Closure - Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 107 | <Input 8> Closure - Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 107 | <Input 8> Closure - Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 107 | <Input 8> Short - Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 107 | <Input 8> Short - Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 107 | <Input 8> Short - Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 107 | <Input 8> Recall/Learn Scene | Scene | 1 Byte | 18.1 scene control | CRT |
| 107 | <Input 8> Sequence Command A 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 107 | <Input 8> Sequence Command A 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 107 | <Input 8> Sequence Command A HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 107 | <Input 8> Sequence Command A 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 107 | <Input 8> Sequence Command A 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 107 | <Input 8> Sequence Command A HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 107 | <Temperature 8> Alarm | Disable/Enable | 1 Bit | 1.1 switch | CRT |
| 107 | <Input 8> Closure Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 107 | <Input 8> Closure - Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 107 | <Input 8> Short - Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 107 | <Input 8> Dimming On/Off | Off/On | 1 Bit | 1.1 switch | CRWT |
| 107 | <Input 8> Object A | Off/On | 1 Bit | 1.1 switch | CRT |
| 107 | <Input 8> Shutter - Up/Down | Up/Down | 1 Bit | 1.8 up/down | CRWT |
| 107 | <Input 8> Sequence Command A Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 107 | <Input 8> Sequence Command A Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 107 | <Input 8> Make Up Room | Off/On | 1 Bit | 1.1 switch | CRT |
| 108 | <Temperature 8> Actual Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 108 | <Input 8> Green | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 108 | <Input 8> Long Closure | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 108 | <Input 8> Long Closure | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 108 | <Input 8> Long Closure | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 108 | <Input 8> Opening Action | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 108 | <Input 8> Opening Action | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 108 | <Input 8> Opening Action | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 108 | <Input 8> Sequence Command B 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 108 | <Input 8> Sequence Command B 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 108 | <Input 8> Sequence Command B HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 108 | <Input 8> Sequence Command B 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 108 | <Input 8> Sequence Command B 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 108 | <Input 8> Sequence Command B HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 108 | <Input 8> Loop Value Output | Loop Value Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 108 | <Input 8> Dimming Control | Brighter/Darker | 4 Bit | 3.7 dimming control | CRT |
| 108 | <Input 8> Long Closure | Off/On | 1 Bit | 1.1 switch | CRWT |
| 108 | <Input 8> Opening Action | Off/On | 1 Bit | 1.1 switch | CRWT |
| 108 | <Input 8> Object B | Off/On | 1 Bit | 1.1 switch | CRT |
| 108 | <Input 8> Shutter - Step/Stop | Step/Stop | 1 Bit | 1.7 step | CRT |
| 108 | <Input 8> Sequence Command B Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 108 | <Input 8> Sequence Command B Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 108 | <Input 8> Send Learn Scene Trigger | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 108 | <Input 8> Do Not Disturb | Off/On | 1 Bit | 1.1 switch | CRT |
| 109 | <Input 8> Additional Object RGB | 3 Bytes | 3 Bytes | 232.600 RGB value 3x(0..255) | CRT |
| 109 | <Temperature 8> KNX Probe Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 109 | <Input 8> Blue | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 109 | <Input 8> Sequence Command C 0-255 | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 109 | <Input 8> Sequence Command C 0-100% | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 109 | <Input 8> Sequence Command C HVAC Mode | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 109 | <Input 8> Sequence Command C 0-255-Toggle | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 109 | <Input 8> Sequence Command C 0-100%-Toggle | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 109 | <Input 8> Sequence Command C HVAC Mode-Toggle | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRT |
| 109 | <Input 8> Loop Value Feedback | Loop Value Feedback | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 109 | <Input 8> Sequence Command C Off/On | Off/On | 1 Bit | 1.1 switch | CRT |
| 109 | <Input 8> Sequence Command C Off/On-Toggle | Off/On | 1 Bit | 1.1 switch | CRT |
| 109 | <Input 8> Feedback | Off/On | 1 Bit | 1.1 switch | CW |
| 109 | <Input 8> Feedback | Up/Down | 1 Bit | 1.8 up/down | CW |
| 109 | <Input 8> Object C | Off/On | 1 Bit | 1.1 switch | CRT |
| 110 | <Input 8> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 110 | <Thermostat 8> Heat/Cool Mode | Heat/Cool | 1 Bit | 1.100 heating/cooling | CW |
| 110 | <Thermostat 8> Heat/Cool Mode | Heat/Cool | 1 Bit | 1.100 heating/cooling | CRT |
| 110 | <T.Sensor 8> Enable Input | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 111 | <T.Sensor 8> Setpoint Upper | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 111 | <Thermostat 8> Window Contact | Close/Open | 1 Bit | 1.19 window/door | CW |
| 112 | <Thermostat 8> Comfort Mode | Off/On | 1 Bit | 1.1 switch | CW |
| 112 | <T.Sensor 8> Telegram Upper | Off/On | 1 Bit | 1.1 switch | CRT |
| 113 | <T.Sensor 8> Setpoint Lower | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 113 | <Thermostat 8> HVAC Mode | Comf/Standby/Eco/B.protection | 1 Byte | 20.102 HVAC mode | CW |
| 114 | <Thermostat 8> Actual Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 114 | <T.Sensor 8> Telegram Lower | Off/On | 1 Bit | 1.1 switch | CRT |
| 115 | <Thermostat 8> Setpoint Adjustment | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 115 | <Thermostat 8> Setpoint Adjustment | Value °C | 1 Bit | 1.7 step | CW |
| 116 | <Thermostat 8> Base Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 116 | <Thermostat 8> SP Economy Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 116 | <Thermostat 8> SP Economy | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 117 | <Thermostat 8> SP Standby Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 117 | <Thermostat 8> SP Standby | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 118 | <Thermostat 8> SP Comfort Heating | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 118 | <Thermostat 8> SP Comfort | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 119 | <Thermostat 8> SP Economy Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 120 | <Thermostat 8> SP Standby Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 121 | <Thermostat 8> SP Comfort Cooling | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 122 | <Thermostat 8> Heating | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 122 | <Thermostat 8> Heating | Off/On | 1 Bit | 1.1 switch | CRT |
| 122 | <Fan Coil 8> Heating/Cooling Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 122 | <Fan Coil 8> Heating Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 123 | <Thermostat 8> Cooling | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 123 | <Thermostat 8> Cooling | Off/On | 1 Bit | 1.1 switch | CRT |
| 123 | <Fan Coil 8> Cooling Valve | Off/On | 1 Bit | 1.1 switch | CRT |
| 124 | <Thermostat 8> 0-100% 2nd Stage Heating | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 124 | <Thermostat 8> Off/On 2nd Stage Heating | Off/On | 1 Bit | 1.1 switch | CRT |
| 125 | <Thermostat 8> 0-100% 2nd Stage Cooling | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 125 | <Thermostat 8> Off/On 2nd Stage Cooling | Off/On | 1 Bit | 1.1 switch | CRT |
| 126 | <Fan Coil 8> Continuous Control % | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 126 | <Fan Coil 8> Speed 1 | Off/On | 1 Bit | 1.1 switch | CRT |
| 127 | <Fan Coil 8> Speed 2 | Off/On | 1 Bit | 1.1 switch | CRT |
| 128 | <Fan Coil 8> Speed 3 | Off/On | 1 Bit | 1.1 switch | CRT |
| 129 | <Fan Coil 8> Set Man/Auto Mode | Manual (0) / Auto (1) | 1 Bit | 1.1 switch | CW |
| 130 | <Fan Coil 8> Force Speed Control in Man Mode | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CW |
| 130 | <Fan Coil 8> Force Value in Man Mode Speed 1 | Off/On | 1 Bit | 1.1 switch | CW |
| 131 | <Fan Coil 8> Force Value in Man Mode Speed 2 | Off/On | 1 Bit | 1.1 switch | CW |
| 132 | <Fan Coil 8> Force Value in Man Mode Speed 3 | Off/On | 1 Bit | 1.1 switch | CW |
| 133 | <Thermostat 8> OFF Thermostat | Off/On | 1 Bit | 1.1 switch | CRWT |
| 134 | <Fan Coil 8> Ventilation Off/On | Off/On | 1 Bit | 1.1 switch | CW |
| 135 | <Additional Valve 8> Percentage | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 135 | <Additional Valve 8> Valve 6 Ways | 0-100% | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 135 | <Additional Valve 8> PWM | Off/On | 1 Bit | 1.1 switch | CRT |
| 136 | <Logic 1> Output 4Byte Count | Output 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CRT |
| 136 | <Logic 1> Output 4Byte UCount | Output 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 136 | <Logic 1> Output 4Byte Float | Output 4Byte Float | 4 Bytes | 14.56 power (W) | CRT |
| 136 | <Logic 1> Output 2Byte Count | Output 2Byte Count | 2 Bytes | 8.1 pulses difference | CRT |
| 136 | <Logic 1> Output 2Byte UCount | Output 2Byte UCount | 2 Bytes | 7.1 pulses | CRT |
| 136 | <Logic 1> Output 2Byte Float | Output 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CRT |
| 136 | <Logic 1> Input Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 136 | <Logic 1> Output | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 136 | <Logic 1> Output Count | Output Count | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 136 | <Logic 1> Output UCount | Output UCount | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 136 | <Logic 1> Output Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 136 | <Logic 1> Input Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CW |
| 136 | <Logic 1> Output | 1 Bit | 1 Bit | 1.2 boolean | CRT |
| 136 | <Logic 1> Output | Logic | 1 Bit | 1.2 boolean | CRT |
| 136 | <Logic 1> Output Bit | Output Bit | 1 Bit | 1.2 boolean | CRT |
| 137 | <Logic 1> Input | 4 Bytes | 4 Bytes | 14.56 power (W) | CW |
| 137 | <Logic 1> Input A 4Byte Count | Input A 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 137 | <Logic 1> Input A 4Byte UCount | Input A 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 137 | <Logic 1> Input A 4Byte Float | Input A 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 137 | <Logic 1> Input | 2 Bytes | 2 Bytes | 9.1 temperature (°C) | CW |
| 137 | <Logic 1> Input A 2Byte Count | Input A 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 137 | <Logic 1> Input A 2Byte UCount | Input A 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 137 | <Logic 1> Input A 2Byte Float | Input A 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 137 | <Logic 1> Input Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 137 | <Logic 1> Input Relative Humidity | Humidity % | 2 Bytes | 9.7 humidity (%) | CW |
| 137 | <Logic 1> Input | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 137 | <Logic 1> Input A Count | Input A Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 137 | <Logic 1> Input A UCount | Input A UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 137 | <Logic 1> Input | Logic | 1 Bit | 1.2 boolean | CW |
| 137 | <Logic 1> Input A | Logic | 1 Bit | 1.2 boolean | CW |
| 137 | <Logic 1> Input | 1 Bit | 1 Bit | 1.2 boolean | CW |
| 137 | <Logic 1> Input A Bit | Input A Bit | 1 Bit | 1.2 boolean | CW |
| 137 | <Logic 1> Input Speed 1 | Off/On | 1 Bit | 1.1 switch | CW |
| 137 | <Logic 1> Output Speed 1 | Off/On | 1 Bit | 1.1 switch | CRT |
| 138 | <Logic 1> Input B 4Byte Count | Input B 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 138 | <Logic 1> Input B 4Byte UCount | Input B 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 138 | <Logic 1> Input B 4Byte Float | Input B 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 138 | <Logic 1> Input B 2Byte Count | Input B 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 138 | <Logic 1> Input B 2Byte UCount | Input B 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 138 | <Logic 1> Input B 2Byte Float | Input B 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 138 | <Logic 1> Input Regulation Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 138 | <Logic 1> Input B Count | Input B Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 138 | <Logic 1> Input B UCount | Input B UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 138 | <Logic 1> Input B | Logic | 1 Bit | 1.2 boolean | CW |
| 138 | <Logic 1> Input B Bit | Input B Bit | 1 Bit | 1.2 boolean | CW |
| 138 | <Logic 1> Input Heat/Cool | Heat/Cool | 1 Bit | 1.100 heating/cooling | CW |
| 138 | <Logic 1> Input Speed 2 | Off/On | 1 Bit | 1.1 switch | CW |
| 138 | <Logic 1> Output Speed 2 | Off/On | 1 Bit | 1.1 switch | CRT |
| 139 | <Logic 1> Input C 4Byte Count | Input C 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 139 | <Logic 1> Input C 4Byte UCount | Input C 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 139 | <Logic 1> Input C 4Byte Float | Input C 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 139 | <Logic 1> Input C 2Byte Count | Input C 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 139 | <Logic 1> Input C 2Byte UCount | Input C 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 139 | <Logic 1> Input C 2Byte Float | Input C 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 139 | <Logic 1> Output Dew Point Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 139 | <Logic 1> Input C Count | Input C Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 139 | <Logic 1> Input C UCount | Input C UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 139 | <Logic 1> Output Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 139 | <Logic 1> Output Heat Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 139 | <Logic 1> Input C Bit | Input C Bit | 1 Bit | 1.2 boolean | CW |
| 139 | <Logic 1> Input Speed 3 | Off/On | 1 Bit | 1.1 switch | CW |
| 139 | <Logic 1> Output Speed 3 | Off/On | 1 Bit | 1.1 switch | CRT |
| 140 | <Logic 1> Input D 4Byte Count | Input D 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 140 | <Logic 1> Input D 4Byte UCount | Input D 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 140 | <Logic 1> Input D 4Byte Float | Input D 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 140 | <Logic 1> Input D 2Byte Count | Input D 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 140 | <Logic 1> Input D 2Byte UCount | Input D 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 140 | <Logic 1> Input D 2Byte Float | Input D 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 140 | <Logic 1> Input D Count | Input D Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 140 | <Logic 1> Input D UCount | Input D UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 140 | <Logic 1> Output Cool Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 140 | <Logic 1> Output Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 140 | <Logic 1> Input D Bit | Input D Bit | 1 Bit | 1.2 boolean | CW |
| 140 | <Logic 1> Input Enable/Disable | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 140 | <Logic 1> Output Command | Off/On | 1 Bit | 1.1 switch | CRT |
| 141 | <Logic 2> Output 4Byte Count | Output 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CRT |
| 141 | <Logic 2> Output 4Byte UCount | Output 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 141 | <Logic 2> Output 4Byte Float | Output 4Byte Float | 4 Bytes | 14.56 power (W) | CRT |
| 141 | <Logic 2> Output 2Byte Count | Output 2Byte Count | 2 Bytes | 8.1 pulses difference | CRT |
| 141 | <Logic 2> Output 2Byte UCount | Output 2Byte UCount | 2 Bytes | 7.1 pulses | CRT |
| 141 | <Logic 2> Output 2Byte Float | Output 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CRT |
| 141 | <Logic 2> Input Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 141 | <Logic 2> Output | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 141 | <Logic 2> Output Count | Output Count | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 141 | <Logic 2> Output UCount | Output UCount | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 141 | <Logic 2> Output Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 141 | <Logic 2> Input Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CW |
| 141 | <Logic 2> Output | 1 Bit | 1 Bit | 1.2 boolean | CRT |
| 141 | <Logic 2> Output | Logic | 1 Bit | 1.2 boolean | CRT |
| 141 | <Logic 2> Output Bit | Output Bit | 1 Bit | 1.2 boolean | CRT |
| 141 | <VH> Room Booked | Room Booked | 1 Bit | 1.2 boolean | CW |
| 142 | <Logic 2> Input | 4 Bytes | 4 Bytes | 14.56 power (W) | CW |
| 142 | <Logic 2> Input A 4Byte Count | Input A 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 142 | <Logic 2> Input A 4Byte UCount | Input A 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 142 | <Logic 2> Input A 4Byte Float | Input A 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 142 | <Logic 2> Input | 2 Bytes | 2 Bytes | 9.1 temperature (°C) | CW |
| 142 | <Logic 2> Input A 2Byte Count | Input A 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 142 | <Logic 2> Input A 2Byte UCount | Input A 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 142 | <Logic 2> Input A 2Byte Float | Input A 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 142 | <Logic 2> Input Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 142 | <Logic 2> Input Relative Humidity | Humidity % | 2 Bytes | 9.7 humidity (%) | CW |
| 142 | <Logic 2> Input | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 142 | <Logic 2> Input A Count | Input A Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 142 | <Logic 2> Input A UCount | Input A UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 142 | <Logic 2> Input | Logic | 1 Bit | 1.2 boolean | CW |
| 142 | <Logic 2> Input A | Logic | 1 Bit | 1.2 boolean | CW |
| 142 | <Logic 2> Input | 1 Bit | 1 Bit | 1.2 boolean | CW |
| 142 | <Logic 2> Input A Bit | Input A Bit | 1 Bit | 1.2 boolean | CW |
| 142 | <Logic 2> Input Speed 1 | Off/On | 1 Bit | 1.1 switch | CW |
| 142 | <Logic 2> Output Speed 1 | Off/On | 1 Bit | 1.1 switch | CRT |
| 142 | <VH> Remote Inputs Enable (Global Enable) | Remote Inputs Enable (Global Enable) | 1 Bit | 1.2 boolean | CW |
| 143 | <Logic 2> Input B 4Byte Count | Input B 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 143 | <Logic 2> Input B 4Byte UCount | Input B 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 143 | <Logic 2> Input B 4Byte Float | Input B 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 143 | <Logic 2> Input B 2Byte Count | Input B 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 143 | <Logic 2> Input B 2Byte UCount | Input B 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 143 | <Logic 2> Input B 2Byte Float | Input B 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 143 | <Logic 2> Input Regulation Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 143 | <Logic 2> Input B Count | Input B Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 143 | <Logic 2> Input B UCount | Input B UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 143 | <Logic 2> Input B | Logic | 1 Bit | 1.2 boolean | CW |
| 143 | <Logic 2> Input B Bit | Input B Bit | 1 Bit | 1.2 boolean | CW |
| 143 | <Logic 2> Input Heat/Cool | Heat/Cool | 1 Bit | 1.100 heating/cooling | CW |
| 143 | <Logic 2> Input Speed 2 | Off/On | 1 Bit | 1.1 switch | CW |
| 143 | <Logic 2> Output Speed 2 | Off/On | 1 Bit | 1.1 switch | CRT |
| 143 | <VH> Presence Output | Presence Output | 1 Bit | 1.2 boolean | CRT |
| 144 | <Logic 2> Input C 4Byte Count | Input C 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 144 | <Logic 2> Input C 4Byte UCount | Input C 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 144 | <Logic 2> Input C 4Byte Float | Input C 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 144 | <Logic 2> Input C 2Byte Count | Input C 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 144 | <Logic 2> Input C 2Byte UCount | Input C 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 144 | <Logic 2> Input C 2Byte Float | Input C 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 144 | <Logic 2> Output Dew Point Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 144 | <Logic 2> Input C Count | Input C Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 144 | <Logic 2> Input C UCount | Input C UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 144 | <Logic 2> Output Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 144 | <Logic 2> Output Heat Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 144 | <VH> HVAC Output | HVAC Output | 1 Byte | 20.102 HVAC mode | CRT |
| 144 | <Logic 2> Input C Bit | Input C Bit | 1 Bit | 1.2 boolean | CW |
| 144 | <Logic 2> Input Speed 3 | Off/On | 1 Bit | 1.1 switch | CW |
| 144 | <Logic 2> Output Speed 3 | Off/On | 1 Bit | 1.1 switch | CRT |
| 145 | <Logic 2> Input D 4Byte Count | Input D 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 145 | <Logic 2> Input D 4Byte UCount | Input D 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 145 | <Logic 2> Input D 4Byte Float | Input D 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 145 | <Logic 2> Input D 2Byte Count | Input D 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 145 | <Logic 2> Input D 2Byte UCount | Input D 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 145 | <Logic 2> Input D 2Byte Float | Input D 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 145 | <Logic 2> Input D Count | Input D Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 145 | <Logic 2> Input D UCount | Input D UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 145 | <Logic 2> Output Cool Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 145 | <Logic 2> Output Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 145 | <VH> Additional Output | Additional Output | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 145 | <Logic 2> Input D Bit | Input D Bit | 1 Bit | 1.2 boolean | CW |
| 145 | <Logic 2> Input Enable/Disable | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 145 | <Logic 2> Output Command | Off/On | 1 Bit | 1.1 switch | CRT |
| 146 | <Logic 3> Output 4Byte Count | Output 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CRT |
| 146 | <Logic 3> Output 4Byte UCount | Output 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 146 | <Logic 3> Output 4Byte Float | Output 4Byte Float | 4 Bytes | 14.56 power (W) | CRT |
| 146 | <Logic 3> Output 2Byte Count | Output 2Byte Count | 2 Bytes | 8.1 pulses difference | CRT |
| 146 | <Logic 3> Output 2Byte UCount | Output 2Byte UCount | 2 Bytes | 7.1 pulses | CRT |
| 146 | <Logic 3> Output 2Byte Float | Output 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CRT |
| 146 | <Logic 3> Input Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 146 | <Logic 3> Output | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 146 | <Logic 3> Output Count | Output Count | 1 Byte | 6.10 counter pulses (-128..127) | CRT |
| 146 | <Logic 3> Output UCount | Output UCount | 1 Byte | 5.10 counter pulses (0..255) | CRT |
| 146 | <Logic 3> Output Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 146 | <Logic 3> Input Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CW |
| 146 | <Logic 3> Output | 1 Bit | 1 Bit | 1.2 boolean | CRT |
| 146 | <Logic 3> Output | Logic | 1 Bit | 1.2 boolean | CRT |
| 146 | <Logic 3> Output Bit | Output Bit | 1 Bit | 1.2 boolean | CRT |
| 147 | <Logic 3> Input | 4 Bytes | 4 Bytes | 14.56 power (W) | CW |
| 147 | <Logic 3> Input A 4Byte Count | Input A 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 147 | <Logic 3> Input A 4Byte UCount | Input A 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 147 | <Logic 3> Input A 4Byte Float | Input A 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 147 | <Logic 3> Input | 2 Bytes | 2 Bytes | 9.1 temperature (°C) | CW |
| 147 | <Logic 3> Input A 2Byte Count | Input A 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 147 | <Logic 3> Input A 2Byte UCount | Input A 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 147 | <Logic 3> Input A 2Byte Float | Input A 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 147 | <Logic 3> Input Setpoint | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 147 | <Logic 3> Input Relative Humidity | Humidity % | 2 Bytes | 9.7 humidity (%) | CW |
| 147 | <Logic 3> Input | 1 Byte | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 147 | <Logic 3> Input A Count | Input A Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 147 | <Logic 3> Input A UCount | Input A UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 147 | <Logic 3> Input | Logic | 1 Bit | 1.2 boolean | CW |
| 147 | <Logic 3> Input A | Logic | 1 Bit | 1.2 boolean | CW |
| 147 | <Logic 3> Input | 1 Bit | 1 Bit | 1.2 boolean | CW |
| 147 | <Logic 3> Input A Bit | Input A Bit | 1 Bit | 1.2 boolean | CW |
| 147 | <Logic 3> Input Speed 1 | Off/On | 1 Bit | 1.1 switch | CW |
| 147 | <Logic 3> Output Speed 1 | Off/On | 1 Bit | 1.1 switch | CRT |
| 147 | <VH> Presence for Guest (Type1) | Presence for Guest (Type1) | 1 Bit | 1.2 boolean | CRT |
| 148 | <Logic 3> Input B 4Byte Count | Input B 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 148 | <Logic 3> Input B 4Byte UCount | Input B 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 148 | <Logic 3> Input B 4Byte Float | Input B 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 148 | <Logic 3> Input B 2Byte Count | Input B 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 148 | <Logic 3> Input B 2Byte UCount | Input B 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 148 | <Logic 3> Input B 2Byte Float | Input B 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 148 | <Logic 3> Input Regulation Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CW |
| 148 | <Logic 3> Input B Count | Input B Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 148 | <Logic 3> Input B UCount | Input B UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 148 | <Logic 3> Input B | Logic | 1 Bit | 1.2 boolean | CW |
| 148 | <Logic 3> Input B Bit | Input B Bit | 1 Bit | 1.2 boolean | CW |
| 148 | <Logic 3> Input Heat/Cool | Heat/Cool | 1 Bit | 1.100 heating/cooling | CW |
| 148 | <Logic 3> Input Speed 2 | Off/On | 1 Bit | 1.1 switch | CW |
| 148 | <Logic 3> Output Speed 2 | Off/On | 1 Bit | 1.1 switch | CRT |
| 148 | <VH> Signal Guest (Type1) | Signal Guest (Type1) | 1 Bit | 1.2 boolean | CW |
| 149 | <Logic 3> Input C 4Byte Count | Input C 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 149 | <Logic 3> Input C 4Byte UCount | Input C 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 149 | <Logic 3> Input C 4Byte Float | Input C 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 149 | <Logic 3> Input C 2Byte Count | Input C 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 149 | <Logic 3> Input C 2Byte UCount | Input C 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 149 | <Logic 3> Input C 2Byte Float | Input C 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 149 | <Logic 3> Output Dew Point Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 149 | <Logic 3> Input C Count | Input C Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 149 | <Logic 3> Input C UCount | Input C UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 149 | <Logic 3> Output Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 149 | <Logic 3> Output Heat Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 149 | <Logic 3> Input C Bit | Input C Bit | 1 Bit | 1.2 boolean | CW |
| 149 | <Logic 3> Input Speed 3 | Off/On | 1 Bit | 1.1 switch | CW |
| 149 | <Logic 3> Output Speed 3 | Off/On | 1 Bit | 1.1 switch | CRT |
| 149 | <VH> Presence for Service (Type2) | Presence for Service (Type2) | 1 Bit | 1.2 boolean | CRT |
| 150 | <Logic 3> Input D 4Byte Count | Input D 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CW |
| 150 | <Logic 3> Input D 4Byte UCount | Input D 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CW |
| 150 | <Logic 3> Input D 4Byte Float | Input D 4Byte Float | 4 Bytes | 14.56 power (W) | CW |
| 150 | <Logic 3> Input D 2Byte Count | Input D 2Byte Count | 2 Bytes | 8.1 pulses difference | CW |
| 150 | <Logic 3> Input D 2Byte UCount | Input D 2Byte UCount | 2 Bytes | 7.1 pulses | CW |
| 150 | <Logic 3> Input D 2Byte Float | Input D 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CW |
| 150 | <Logic 3> Input D Count | Input D Count | 1 Byte | 6.10 counter pulses (-128..127) | CW |
| 150 | <Logic 3> Input D UCount | Input D UCount | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 150 | <Logic 3> Output Cool Valve % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 150 | <Logic 3> Output Value % | Value % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 150 | <Logic 3> Input D Bit | Input D Bit | 1 Bit | 1.2 boolean | CW |
| 150 | <Logic 3> Input Enable/Disable | Disable/Enable | 1 Bit | 1.3 enable | CW |
| 150 | <Logic 3> Output Command | Off/On | 1 Bit | 1.1 switch | CRT |
| 150 | <VH> Signal Service (Type2) | Signal Service (Type2) | 1 Bit | 1.2 boolean | CW |
| 151 | <Logic 4> Output 4Byte Count | Output 4Byte Count | 4 Bytes | 13.1 counter pulses (signed) | CRT |
| 151 | <Logic 4> Output 4Byte UCount | Output 4Byte UCount | 4 Bytes | 12.1 counter pulses (unsigned) | CRT |
| 151 | <Logic 4> Output 4Byte Float | Output 4Byte Float | 4 Bytes | 14.56 power (W) | CRT |
| 151 | <Logic 4> Output 2Byte Count | Output 2Byte Count | 2 Bytes | 8.1 pulses difference | CRT |
| 151 | <Logic 4> Output 2Byte UCount | Output 2Byte UCount | 2 Bytes | 7.1 pulses | CRT |
| 151 | <Logic 4> Output 2Byte Float | Output 2Byte Float | 2 Bytes | 9.1 temperature (°C) | CRT |
First 1000 of 1161 group objects shown. Download the .knxprod for the full list.
Parameters (305)
| Parameter | Type | Default |
|---|---|---|
| Delay to send telegrams on power up [s] | unsignedInt 5…15 | 5 |
| Input 5 | list | digital |
| Input 6 | list | digital |
| Input 7 | list | digital |
| Input 8 | list | digital |
| Temperature alarm object 5 | list | disabled |
| Temperature alarm object 6 | list | disabled |
| Temperature alarm object 7 | list | disabled |
| Temperature alarm object 8 | list | disabled |
| Virtual holder | list | disabled |
| Temperature function | list | thermostat |
| LED configuration | list | always off |
| LED activation telegram | list | telegram "1" |
| LED initial State | list | off |
| LED blink period | list | fixed |
| Function | list | nothing |
| Contact type | list | normally open |
| Debounce time for inputs | list | 80 ms |
| Object enable | list | disabled |
| Initial enable state | list | enabled |
| Enable activation telegram | list | telegram "1" |
| Telegram associated | list | 1 bit |
| Long or short cyclic times | list | short |
| Command associated with closure | list | on |
| Cyclic sending when contact closed | list | never |
| Feedback object | list | disabled |
| Command associated with closure | list | value 0-100% |
| Value associated with closure | unsignedInt 0…255 | 0 |
| Value associated with closure | list | 0% |
| Value associated with closure | list | auto |
| Command associated with closure | list | nothing |
| Command associated with opening | list | nothing |
| Command type | list | value 0-100% |
| Value associated with opening | unsignedInt 0…255 | 0 |
| Value associated with opening | list | 0% |
| Value associated with opening | list | auto |
| Communication object on opening | list | disabled |
| Cyclic sending when contact opened | list | never |
| Minimum time long closure | list | 0.5 s |
| Command associated with short closure | list | nothing |
| Command associated with long closure | list | nothing |
| Value associated with short closure | unsignedInt 0…255 | 0 |
| Value associated with short closure | list | 0% |
| Value associated with short closure | list | auto |
| Value associated with long closure | unsignedInt 0…255 | 0 |
| Value associated with long closure | list | 0% |
| Value associated with long closure | list | auto |
| Communication object on long closure | list | disabled |
| Dimming mode | list | brighter/darker |
| Dimming step | list | maximum brightness |
| Dimming step | list | minimum brightness |
| Dimming step | list | maximum/minimum brightness |
| Command drive shutter | list | move up/move down |
| Minimum time long closure | list | 2.0 s |
| Scene number (1-64) | list | 1 |
| Store scene on long closure | list | disabled |
| Object enable scene learning from bus | list | disabled |
| Delay between commands | unsignedInt 0…255 | 0 |
| Telegram associated with command A | list | 1 bit |
| Telegram associated with command B | list | 1 bit |
| Telegram associated with command C | list | 1 bit |
| Command type | list | nothing |
| Value associated with operation 1 | unsignedInt 0…255 | 0 |
| Value associated with operation 1 | list | 0% |
| Value associated with operation 1 | list | auto |
| Value associated with operation 2 | unsignedInt 0…255 | 0 |
| Value associated with operation 2 | list | 0% |
| Value associated with operation 2 | list | auto |
| Command associated with operation 1 | list | nothing |
| Command associated with operation 2 | list | nothing |
| Number of objects | list | 2 objects |
| Send only changed objects | list | disabled |
| Number of steps in the sequence | list | 2 |
| Long closure to restart sequence | list | disabled |
| Min. time long closure to restart sequence | list | 1.0 s |
| Restart function | list | restart and send first |
| Value step long | list | a=off b=off c=off |
| Value step long | list | a=off b=off |
| Value step 1 | list | a=off b=off c=off |
| Value step 2 | list | a=off b=off c=off |
| Value step 3 | list | a=off b=off c=off |
| Value step 4 | list | a=off b=off c=off |
| Value step 5 | list | a=off b=off c=off |
| Value step 6 | list | a=off b=off c=off |
| Value step 7 | list | a=off b=off c=off |
| Value step 8 | list | a=off b=off c=off |
| Value step 1 | list | a=off b=off |
| Value step 2 | list | a=off b=off |
| Value step 3 | list | a=off b=off |
| Value step 4 | list | a=off b=off |
| Software filter frequency | list | no filter |
| Counter input size | list | 1 byte |
| Condition of increase counter | list | rising edge |
| Send counter on time base | list | no cyclic sending |
| Send counter on variation base (0=Disable) | unsignedInt 0…255 | 1 |
| Telegram associated to overflow | list | nothing |
| End counter value | unsignedInt 1…255 | 255 |
| End counter value | unsignedInt 1…65535 | 65535 |
| End counter value | unsignedInt 1…4294967295 | 4294967295 |
| Start counter value | unsignedInt 0…254 | 0 |
| Start counter value | unsignedInt 0…65534 | 0 |
| Start counter value | unsignedInt 0…4294967294 | 0 |
| Command associated | list | off |
| Command type | list | value 0-255 |
| Value associated of overflow | unsignedInt 0…255 | 0 |
| Value associated of overflow | list | 0% |
| Value associated of overflow | list | auto |
| Set value | list | red |
| Long closure to change color | list | long closure disabled |
| Enable sending colors during transitions | list | disabled |
| RGB objects type | list | 3 objects of 1 byte |
| Command associated | list | reset all |
| Action associated with closure | list | enable |
| Color associated to "reset all" | text | #FFFFFF |
| Color associated to "make up room" | text | #00FF00 |
| Color associated to "do not disturb" | text | #FF0000 |
| Additional object | list | none |
| Active edge | list | send on closing |
| Number of values | list | 3 values |
| Value A | unsignedInt 0…255 | 0 |
| Value B | unsignedInt 0…255 | 1 |
| Value C | unsignedInt 0…255 | 2 |
| Value D | unsignedInt 0…255 | 3 |
| Value E | unsignedInt 0…255 | 4 |
| Value F | unsignedInt 0…255 | 5 |
| Value G | unsignedInt 0…255 | 6 |
| Value H | unsignedInt 0…255 | 7 |
| Value I | unsignedInt 0…255 | 8 |
| Use thermostat to control fan coils | list | yes |
| Fan coil type | list | fan coil control on / off |
| Enable 2nd stage control | list | disabled |
| Thermostat control mode | list | HVAC mode (switched heat/cool) |
| Value of heat/cool object after download | list | 1 = heating |
| Value of HVAC mode object after download | list | off (frost / high temperature protection) |
| Enable 1bit comfort object | list | disabled |
| Control type when comfort ends | list | standby |
| Comfort object priority | list | no |
| Comfort object timing | list | time unlimited |
| Comfort overwrite time [min] | unsignedInt 1…255 | 1 |
| Enable setpoint adjustment object | list | enabled |
| Window contact | list | disabled |
| Window contact activation telegram | list | telegram "1" |
| Thermostat OFF object | list | disabled |
| Thermostat OFF activation telegram | list | telegram "1" |
| Setpoint frost protection | list | 7°C |
| Setpoint economy heating (Teh) | list | 16°C |
| Setpoint standby heating (Tsh) | list | 18°C |
| Setpoint comfort heating (Tch) | list | 20°C |
| Setpoint high temperature protection | list | 35°C |
| Setpoint economy cooling (Tec) | list | 28°C |
| Setpoint standby cooling (Tsc) | list | 26°C |
| Setpoint comfort cooling (Tcc) | list | 24°C |
| Action to execute for setpoint | list | modify absolute |
| Value of base setpoint object after download | list | 20°C |
| Dead band | list | 2°C |
| Control algorithm | list | 2 points on/off control |
| Time period for on/off cyclic sending | list | no cyclic sending |
| Regulation differential value - heating | list | 0.4°C |
| Proportional band [Bp] | list | 1°C |
| Cycle time | list | 10 min |
| Integration time [min] [Ti] | unsignedInt 5…250 | 200 |
| Regulation differential value - cooling | list | 0.4°C |
| Reset SP adjustment on HEAT/COOL change | list | reset |
| Reset SP adjustment on HVAC economy | list | no reset |
| Adjustment allowed | list | -/+ 3°C |
| Setpoint adjustment value format | list | 2 bytes object - temperature value |
| Increase setpoint adjustment with | list | telegram "1" |
| Resolution | list | 0.5°C |
| Keep SP adjustment on power up | list | enabled |
| Enable fancoil speeds on | list | heating / cooling |
| System type | list | 2 pipes |
| Enable additional valve | list | disabled |
| Speed number | list | 3 speed |
| Regulation differential value S1-SP heat | list | 0°C |
| Regulation differential value SP-S1 cool | list | 0°C |
| Regulation differential value S1-S2 heat | list | 0.8°C |
| Regulation differential value S2-S1 cool | list | 0.8°C |
| Regulation differential value S2-S3 heat | list | 0.8°C |
| Regulation differential value S3-S2 cool | list | 0.8°C |
| Manage valve independently | list | no |
| Regulation differential valve-cool-ON | list | 0.8°C |
| Regulation differential valve-heat-ON | list | 0.8°C |
| Regulation differential valve-cool-OFF | list | 0.8°C |
| Regulation differential valve-heat-OFF | list | 0.8°C |
| Initial value MAN (0) / AUTO (1) object | list | 1 |
| Enable ventilation object on/off | list | disabled |
| Ventilation after download | list | off |
| Integration time heat [min] [Ti] | unsignedInt 5…250 | 120 |
| Proportional band heat [Bp] | list | 1°C |
| Integration time cool [min] [Ti] | unsignedInt 5…250 | 120 |
| Proportional band cool [Bp] | list | 1°C |
| 2nd stage heating | list | enabled |
| 2nd stage heating telegram | list | 1 bit |
| Activation telegram 2nd stage heating | list | telegram "1" |
| 2nd stage cooling | list | enabled |
| 2nd stage cooling telegram | list | 1 bit |
| Activation telegram 2nd stage cooling | list | telegram "1" |
| Bandgap | list | 0°C |
| Proportional band [Bp] | list | 2.0°C |
| Control type | list | proportional |
| Integration time [min] [Ti] | unsignedInt 5…250 | 120 |
| Integration time [min] [Ti] | unsignedInt 5…255 | 120 |
| Control algorithm | list | integral proportional control PWM |
| Control algorithm 6 ways | list | nothing |
| Enable valve when | list | cooling |
| Percentage 100% cool | list | 0% |
| Percentage 0% cool | list | 33% |
| Value to send for valve fully closed | list | 50% |
| Percentage 0% heat | list | 67% |
| Percentage 100% heat | list | 100% |
| Set the differential values of the band | list | no |
| Proportional band [Bp] | list | 2°C |
| Regulation differential valve 0% | list | 0°C |
| Regulation differential valve 100% | list | 2.0°C |
| Activation telegram | list | telegram "1" |
| State after download | list | enabled |
| Hysteresis | list | 0.5°C |
| Upper setpoint value | list | +25°C |
| Telegram when value is above setpoint | list | on |
| Telegram when value is below setpoint | list | off |
| Telegram when probe is disabled | list | off |
| Cyclic sending time of telegram | list | no cyclic send |
| Lower setpoint value | list | +20°C |
| Telegram when value is above setpoint | list | off |
| Telegram when value is below setpoint | list | on |
| Temperature source | list | external probe |
| Temperature object | list | disabled |
| Sensor code | list | TS01A01ACC |
| Weight external probe | list | 50% |
| External sensor calibration [0.1°C] | signedInt -100…100 | 0 |
| KNX sensor calibration [0.1°C] | signedInt -100…100 | 0 |
| Sending interval | list | never |
| Sending on variation | list | never |
| Surveillance time for KNX probe (0=disabled) [min] | unsignedInt 0…255 | 15 |
| Logic function | list | disabled |
| Logic delay | list | 0 |
| Number of transmissions on output | list | 1 |
| Retransmission delay | list | 2 s |
| Value sent when 0 is received | unsignedInt 0…255 | 0 |
| Value sent when 1 is received | unsignedInt 0…255 | 128 |
| Byte value | unsignedInt 0…255 | 128 |
| Output bit when byte is received | list | 1 |
| Output bit otherwise | list | 0 |
| Threshold value | unsignedInt 0…255 | 128 |
| Output bit when input > threshold | list | 1 |
| Output bit when input <= threshold | list | 0 |
| Threshold value | float -671088…670760 | 0 |
| Threshold value | float -9223372036854776000…8762203435012037000 | 0 |
| Dead band [0.1°C] | unsignedInt 0…255 | 20 |
| Proportional band [Bp] [0.1°C] | unsignedInt 0…255 | 30 |
| Proportional conversion | list | bit to proportional |
| Lower limit value | unsignedInt 0…255 | 0 |
| Value to send for speed 1 | unsignedInt 0…255 | 85 |
| Limit value speed 1/2 | unsignedInt 0…255 | 85 |
| Value to send for speed 2 | unsignedInt 0…255 | 170 |
| Limit value speed 2/3 | unsignedInt 0…255 | 170 |
| Value to send for speed 3 | unsignedInt 0…255 | 255 |
| Bandgap [0.1°C] | signedInt -128…127 | 0 |
| Altitude (tens of meters above sea level) | unsignedInt 0…255 | 50 |
| Output type | list | off/on |
| Inverted control | list | no |
| DPT Output | list | 1 bit |
| DPT Input A | list | 1 bit |
| DPT Input B | list | 1 bit |
| DPT Input C | list | 1 bit |
| DPT Input D | list | 1 bit |
| Logic expression | text | 0 |
| Logic version | list | first version |
| Presence Wait Time | list | 15 min |
| Cyclic Presence Send Time | list | no cyclic send |
| Presence sensor OFF latency [s] | unsignedInt 0…63 | 10 |
| Send welcome on unexpected presence | list | do not send |
| Global Enable state after download | list | disabled |
| Booked state after download | list | not booked |
| Absence with door open (deny=if door open presence is active) | list | allow |
| Local input type 1 | list | disabled |
| Contact type 1 | list | contact closed with door closed |
| Contact type 1 | list | normally open |
| Local input type 2 | list | disabled |
| Contact type 2 | list | contact closed with door closed |
| Contact type 2 | list | normally open |
| Local input type 3 | list | disabled |
| Contact type 3 | list | contact closed with door closed |
| Contact type 3 | list | normally open |
| Local input type 4 | list | disabled |
| Contact type 4 | list | contact closed with door closed |
| Contact type 4 | list | normally open |
| Remote input type 1 | list | disabled |
| Subordinate to Remote Inputs Enable | list | not subordinate |
| Remote input type 2 | list | disabled |
| Remote input type 3 | list | disabled |
| Remote input type 4 | list | disabled |
| Remote input type 5 | list | disabled |
| HVAC booked goodbye | list | do not send |
| HVAC non-booked goodbye | list | do not send |
| HVAC booked welcome | list | do not send |
| HVAC non-booked welcome | list | do not send |
| Send additional booked goodbye | list | do not send |
| Value additional booked goodbye | unsignedInt 0…255 | 0 |
| Send additional non-booked goodbye | list | do not send |
| Value additional non-booked goodbye | unsignedInt 0…255 | 0 |
| Send additional booked welcome | list | do not send |
| Value additional booked welcome | unsignedInt 0…255 | 0 |
| Send additional non-booked welcome | list | do not send |
| Value additional non-booked welcome | unsignedInt 0…255 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| AD84C01KNX 1.1 latest | $0608 | E96A | 2026-11-25 | 500 KB | Download |
About this file
This is the official ETS product database for the Eelectron AD84C01KNX Analog / Digital Module 8 Input / 4 led Output (AD84C01KNX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Eelectron
- IO04F01KNX Din Rail 4 Input / 4 Output Module - F01 IO04F01KNX
- IO08F01KNX Din Rail 8 Input / 8 Output Module - F01 IO08F01KNX
- IO12F01KNX Din Rail 12 Input / 12 Output Module - F01 IO12F01KNX
- IO16F01KNX Din Rail 16 Input / 16 Output Module - F01 IO16F01KNX
- IO22D01KNX Inwall 2 In / 2 Out Module - D01 IO22D01KNX
- IO22D02KNX Inwall Pushbutton Interface 2 IN / 2 OUT LED - KNX - D02 IO22D02KNX
- IO32D01KNX Inwall 3 In / 2 Out Module - D01 IO32D01KNX
- IO42E01KNX Inwall 4 In / 2 Out Module - E01 IO42E01KNX
- IO44D01KNX Inwall 4 In / 4 Out Module - D01 IO44D01KNX
- IO44D02KNX Inwall Pushbutton Interface 4 IN / 4 OUT LED - KNX - D02 IO44D02KNX
- IO44D02KNX-S Inwall Pushbutton Interface 4 IN / 4 OUT LED - KNX Secure - D02 IO44D02KNX-S
- IO62D01KNX Inwall 6 In / 2 Out Module - D01 IO62D01KNX