UD106 Universal Dimming Actuator 48266
EAE · Order number 48266 · Lighting
UD106 Universal Dimming Actuator, 6 Channels
Download .knxprod UD106 Universal Dimming Actuator 1.0 · 224 KB
Product
| Manufacturer | EAE |
|---|---|
| Product name | UD106 Universal Dimming Actuator |
| Order number | 48266 |
| Hardware | SMP UD106 EAE KNX |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Registration | Certified · 2022-06-28 |
| Languages | de-DE, es-ES, fr-FR, it-IT, en-US |
| Catalog entry | M-011E_H-48266-1_HP-BC8A-10-DFB7_CI-48266-1 |
| Fingerprint | DFB7 |
| SHA-256 | 1b1763e6b8371290f9bf923c2f6749d67833de5d6f51c996d0861a1c9fc5be27 |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: UD106 Universal Dimming Actuator 1.0
| Application number | $BC8A |
|---|---|
| Version | 1.0 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 849 |
| Group objects | 122 |
Group objects (122)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | In Operation | Output | 1 Bit | 1.2 boolean | CRT |
| 1 | Scene Control Input | Input | 1 Byte | 18.1 scene control | CWU |
| 2 | Channel A: Switching | Input | 1 Bit | 1.1 switch | CWU |
| 3 | Channel A: Switching Status | Output | 1 Bit | 1.1 switch | CRT |
| 4 | Channel A: Absolute Dimming | Input | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 5 | Channel A: Relative Dimming | Input | 4 Bit | 3.7 dimming control | CWU |
| 6 | Channel A: Dimming Status | Output | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 7 | Channel A: Forced Operation | Input | 1 Bit | 1.3 enable | CWU |
| 8 | Channel A: Forced Operation | Input | 2 Bit | 2.1 switch control | CWU |
| 9 | Channel A: Forced Operation Status | Output | 1 Bit | 1.3 enable | CRT |
| 10 | Channel A: Staircase Switch | Input | 1 Bit | 1.1 switch | CWU |
| 11 | Channel A: Staircase Permanent On | Input | 1 Bit | 1.3 enable | CWU |
| 12 | Channel A: Voltage (rms) | Output | 4 Bytes | 14.27 electric potential (V) | CRT |
| 13 | Channel A: Load Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 14 | Channel A: Main Power Failure | Error Output | 1 Bit | 1.5 alarm | CRT |
| 15 | Channel A: Undervoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 16 | Channel A: Overcurrent Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 17 | Channel A: Overvoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 18 | Channel A: Overheating Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 19 | Channel A: Short Circuit Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 20 | Channel A: Hardware Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 21 | Channel A: Overvoltage Lock | Error Output | 1 Bit | 1.5 alarm | CRT |
| 22 | Channel B: Switching | Input | 1 Bit | 1.1 switch | CWU |
| 23 | Channel B: Switching Status | Output | 1 Bit | 1.1 switch | CRT |
| 24 | Channel B: Absolute Dimming | Input | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 25 | Channel B: Relative Dimming | Input | 4 Bit | 3.7 dimming control | CWU |
| 26 | Channel B: Dimming Status | Output | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 27 | Channel B: Forced Operation | Input | 1 Bit | 1.3 enable | CWU |
| 28 | Channel B: Forced Operation | Input | 2 Bit | 2.1 switch control | CWU |
| 29 | Channel B: Forced Operation Status | Output | 1 Bit | 1.3 enable | CRT |
| 30 | Channel B: Staircase Switch | Input | 1 Bit | 1.1 switch | CWU |
| 31 | Channel B: Staircase Permanent On | Input | 1 Bit | 1.3 enable | CWU |
| 32 | Channel B: Voltage (rms) | Output | 4 Bytes | 14.27 electric potential (V) | CRT |
| 33 | Channel B: Load Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 34 | Channel B: Main Power Failure | Error Output | 1 Bit | 1.5 alarm | CRT |
| 35 | Channel B: Undervoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 36 | Channel B: Overcurrent Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 37 | Channel B: Overvoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 38 | Channel B: Overheating Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 39 | Channel B: Short Circuit Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 40 | Channel B: Hardware Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 41 | Channel B: Overvoltage Lock | Error Output | 1 Bit | 1.5 alarm | CRT |
| 42 | Channel C: Switching | Input | 1 Bit | 1.1 switch | CWU |
| 43 | Channel C: Switching Status | Output | 1 Bit | 1.1 switch | CRT |
| 44 | Channel C: Absolute Dimming | Input | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 45 | Channel C: Relative Dimming | Input | 4 Bit | 3.7 dimming control | CWU |
| 46 | Channel C: Dimming Status | Output | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 47 | Channel C: Forced Operation | Input | 1 Bit | 1.3 enable | CWU |
| 48 | Channel C: Forced Operation | Input | 2 Bit | 2.1 switch control | CWU |
| 49 | Channel C: Forced Operation Status | Output | 1 Bit | 1.3 enable | CRT |
| 50 | Channel C: Staircase Switch | Input | 1 Bit | 1.1 switch | CWU |
| 51 | Channel C: Staircase Permanent On | Input | 1 Bit | 1.3 enable | CWU |
| 52 | Channel C: Voltage (rms) | Output | 4 Bytes | 14.27 electric potential (V) | CRT |
| 53 | Channel C: Load Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 54 | Channel C: Main Power Failure | Error Output | 1 Bit | 1.5 alarm | CRT |
| 55 | Channel C: Undervoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 56 | Channel C: Overcurrent Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 57 | Channel C: Overvoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 58 | Channel C: Overheating Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 59 | Channel C: Short Circuit Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 60 | Channel C: Hardware Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 61 | Channel C: Overvoltage Lock | Error Output | 1 Bit | 1.5 alarm | CRT |
| 62 | Channel D: Switching | Input | 1 Bit | 1.1 switch | CWU |
| 63 | Channel D: Switching Status | Output | 1 Bit | 1.1 switch | CRT |
| 64 | Channel D: Absolute Dimming | Input | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 65 | Channel D: Relative Dimming | Input | 4 Bit | 3.7 dimming control | CWU |
| 66 | Channel D: Dimming Status | Output | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 67 | Channel D: Forced Operation | Input | 1 Bit | 1.3 enable | CWU |
| 68 | Channel D: Forced Operation | Input | 2 Bit | 2.1 switch control | CWU |
| 69 | Channel D: Forced Operation Status | Output | 1 Bit | 1.3 enable | CRT |
| 70 | Channel D: Staircase Switch | Input | 1 Bit | 1.1 switch | CWU |
| 71 | Channel D: Staircase Permanent On | Input | 1 Bit | 1.3 enable | CWU |
| 72 | Channel D: Voltage (rms) | Output | 4 Bytes | 14.27 electric potential (V) | CRT |
| 73 | Channel D: Load Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 74 | Channel D: Main Power Failure | Error Output | 1 Bit | 1.5 alarm | CRT |
| 75 | Channel D: Undervoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 76 | Channel D: Overcurrent Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 77 | Channel D: Overvoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 78 | Channel D: Overheating Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 79 | Channel D: Short Circuit Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 80 | Channel D: Hardware Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 81 | Channel D: Overvoltage Lock | Error Output | 1 Bit | 1.5 alarm | CRT |
| 82 | Channel E: Switching | Input | 1 Bit | 1.1 switch | CWU |
| 83 | Channel E: Switching Status | Output | 1 Bit | 1.1 switch | CRT |
| 84 | Channel E: Absolute Dimming | Input | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 85 | Channel E: Relative Dimming | Input | 4 Bit | 3.7 dimming control | CWU |
| 86 | Channel E: Dimming Status | Output | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 87 | Channel E: Forced Operation | Input | 1 Bit | 1.3 enable | CWU |
| 88 | Channel E: Forced Operation | Input | 2 Bit | 2.1 switch control | CWU |
| 89 | Channel E: Forced Operation Status | Output | 1 Bit | 1.3 enable | CRT |
| 90 | Channel E: Staircase Switch | Input | 1 Bit | 1.1 switch | CWU |
| 91 | Channel E: Staircase Permanent On | Input | 1 Bit | 1.3 enable | CWU |
| 92 | Channel E: Voltage (rms) | Output | 4 Bytes | 14.27 electric potential (V) | CRT |
| 93 | Channel E: Load Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 94 | Channel E: Main Power Failure | Error Output | 1 Bit | 1.5 alarm | CRT |
| 95 | Channel E: Undervoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 96 | Channel E: Overcurrent Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 97 | Channel E: Overvoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 98 | Channel E: Overheating Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 99 | Channel E: Short Circuit Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 100 | Channel E: Hardware Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 101 | Channel E: Overvoltage Lock | Error Output | 1 Bit | 1.5 alarm | CRT |
| 102 | Channel F: Switching | Input | 1 Bit | 1.1 switch | CWU |
| 103 | Channel F: Switching Status | Output | 1 Bit | 1.1 switch | CRT |
| 104 | Channel F: Absolute Dimming | Input | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 105 | Channel F: Relative Dimming | Input | 4 Bit | 3.7 dimming control | CWU |
| 106 | Channel F: Dimming Status | Output | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 107 | Channel F: Forced Operation | Input | 1 Bit | 1.3 enable | CWU |
| 108 | Channel F: Forced Operation | Input | 2 Bit | 2.1 switch control | CWU |
| 109 | Channel F: Forced Operation Status | Output | 1 Bit | 1.3 enable | CRT |
| 110 | Channel F: Staircase Switch | Input | 1 Bit | 1.1 switch | CWU |
| 111 | Channel F: Staircase Permanent On | Input | 1 Bit | 1.3 enable | CWU |
| 112 | Channel F: Voltage (rms) | Output | 4 Bytes | 14.27 electric potential (V) | CRT |
| 113 | Channel F: Load Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 114 | Channel F: Main Power Failure | Error Output | 1 Bit | 1.5 alarm | CRT |
| 115 | Channel F: Undervoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 116 | Channel F: Overcurrent Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 117 | Channel F: Overvoltage Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 118 | Channel F: Overheating Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 119 | Channel F: Short Circuit Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 120 | Channel F: Hardware Error | Error Output | 1 Bit | 1.5 alarm | CRT |
| 121 | Channel F: Overvoltage Lock | Error Output | 1 Bit | 1.5 alarm | CRT |
Parameters (141)
| Parameter | Type | Default |
|---|---|---|
| Manual Operation button | list | Active always |
| Enable sending In Operation | list | No |
| In Operation sending period | time | 300 |
| Bit value | list | 1 |
| Channel A | list | Individual |
| Channel B | list | Individual |
| Channel C | list | Individual |
| Channel D | list | Individual |
| ChannelActive_A | list | 0 |
| ChannelActive_B | list | 0 |
| ChannelActive_C | list | 0 |
| ChannelActive_D | list | 0 |
| GroupMaster_1 | unsignedInt 0…255 | 0 |
| GroupMaster_2 | unsignedInt 0…255 | 0 |
| Enable telegram limiting | list | Yes |
| Telegram Limit period duration | list | 50ms |
| PAR_General_TlgLimit_Period_None_0 | unsignedInt 0…65535 | 0 |
| __DimCurveActive_ChA | list | 0 |
| Dimming method | list | Auto detect based on the load type |
| Dimming characteristic | list | Linear |
| Maximum dimming percentage | unsignedInt 0…100 | 100 |
| Minimum dimming percentage | unsignedInt 0…100 | 0 |
| Switch On dimming value | list | 100% |
| Dimming time to Switch On value (From 0% to 100%) | time | 20 |
| Switch Off dimming value | unsignedInt 0…100 | 0 |
| Dimming time to Switch Off value (From 0% to 100%) | time | 20 |
| Dimming time for absolute dimming value input (From 0% to 100%) | time | 30 |
| Allow switching on via absolute dimming value | list | Yes |
| Allow switching off via absolute dimming value | list | Yes |
| Dimming time for relative dimming control (From 0% to 100%) | time | 30 |
| Allow switching on via relative dimming control | list | Yes |
| Allow switching off via relative dimming control | list | Yes |
| Enable switching status object | list | Yes |
| Enable dimming status object | list | Yes |
| Switching status sending mode | list | Transmit on change |
| Dimming status sending mode | list | Transmit on change |
| Enable comm. object "Ovecurrent Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Overvoltage Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Undervoltage Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Load Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Overheating Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Short Circuit Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Hardware Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Main Failure Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Channel Lock Error" | unsignedInt 0…255 | 1 |
| Enable comm. object "Voltage (rms) Measurement" | list | Yes |
| Enable cyclic sending of Voltage (rms) | list | Yes |
| Voltage (rms) sending period | time | 2 |
| Forced Operation function | list | 1 bit format |
| Dimming time for Forced Operation function (From 0% to 100%) | time | 30 |
| Dimming value during Forced Position On | list | 100% |
| Dimming value during Forced Position Off | unsignedInt 0…100 | 0 |
| Dimming value during Forced Operation | list | 100% |
| Dimming value during Staircase On | unsignedInt 0…100 | 100 |
| Dimming time to Staircase On dimming value (From 0% to 100%) | time | 15 |
| Staircase On time | time | 10 |
| Enable Staircase Warning | list | No |
| Dimming value for Staircase Warning | unsignedInt 0…100 | 50 |
| Dimming time to Staircase Warning dimming value (From 0% to 100%) | time | 40 |
| Staircase Warning time | time | 5 |
| Enable communication object "Staircase Permanent" | list | No |
| Dimming value during Permanent On | unsignedInt 0…100 | 100 |
| Dimming time to Permanent On value | time | 15 |
| Dimming time to Staircase switch off (From 0% to 100%) | time | 30 |
| Re-trigger Staircase after Permanent On disabled | list | Yes |
| Dimming value after mains power recovery | list | Status as prior to failure |
| Dimming value after KNX bus failure | list | Status as prior to failure |
| Dimming value after KNX bus recovery | list | Status as prior to failure |
| Forced Operation status after KNX bus recovery | list | Status as prior to failure |
| Forced Operation status after mains power recovery | list | Status as prior to failure |
| Dimming Section 2 Threshold (th2) | unsignedInt 0…100 | 25 |
| Dimming Section 3 Threshold (th3) | unsignedInt 0…100 | 50 |
| Dimming Section 4 Threshold (th4) | unsignedInt 0…100 | 75 |
| Dimming Section 1 Time Factor | unsignedInt 1…255 | 1 |
| Dimming Section 2 Time Factor | unsignedInt 1…255 | 1 |
| Dimming Section 3 Time Factor | unsignedInt 1…255 | 1 |
| Dimming Section 4 Time Factor | unsignedInt 1…255 | 1 |
| Parameter setting | list | Take over from master |
| Enable cyclic sending of Voltage (rms) | list | No |
| Voltage (rms) sending period | time | 0 |
| Forced Operation function | list | Active (1 bit format) |
| Staircase function | list | Disabled |
| Scene 1: | list | Not used |
| Scene 2: | list | Not used |
| Scene 3: | list | Not used |
| Scene 4: | list | Not used |
| Scene 5: | list | Not used |
| Scene 6: | list | Not used |
| Scene 7: | list | Not used |
| Scene 8: | list | Not used |
| Scene 9: | list | Not used |
| Scene 10: | list | Not used |
| Scene 11: | list | Not used |
| Scene 12: | list | Not used |
| Scene 13: | list | Not used |
| Scene 14: | list | Not used |
| Scene 15: | list | Not used |
| Scene 16: | list | Not used |
| Scene 32: | list | Not used |
| Scene 31: | list | Not used |
| Scene 30: | list | Not used |
| Scene 29: | list | Not used |
| Scene 28: | list | Not used |
| Scene 27: | list | Not used |
| Scene 26: | list | Not used |
| Scene 25: | list | Not used |
| Scene 24: | list | Not used |
| Scene 23: | list | Not used |
| Scene 22: | list | Not used |
| Scene 21: | list | Not used |
| Scene 20: | list | Not used |
| Scene 19: | list | Not used |
| Scene 18: | list | Not used |
| Scene 17: | list | Not used |
| Dimming time to scene values (From 0% to 100%) | time | 30 |
| Overwrite scene values on download | unsignedInt 0…255 | 1 |
| Channel A scene value | list | Don't change (Not a part of this scene) |
| Channel B scene value | list | Don't change (Not a part of this scene) |
| Channel C scene value | list | Don't change (Not a part of this scene) |
| Channel D scene value | list | Don't change (Not a part of this scene) |
| __SceneObjectEnabled | list | 0 |
| Telegram Limit count | unsignedInt 1…255 | 10 |
| Enable comm. object "Mains Fault Error" | unsignedInt 0…255 | 1 |
| __DimCurveError_Master | list | 0 |
| __DimCurveActive_ChB | list | 0 |
| __DimCurveActive_ChC | list | 0 |
| __DimCurveActive_ChD | list | 0 |
| Telegram Tranmission Delay (After KNX bus recovery) | unsignedInt 1…255 | 1 |
| Sending cycle | unsignedInt 1…255 | 3 |
| Send intermediate values at transition(e.g. dimming transition) | list | No |
| __DimCurveActive_ChE | list | 0 |
| __DimCurveError_ChE | list | 0 |
| ChannelActive_E | list | 0 |
| Channel E | list | Individual |
| __DimCurveActive_ChF | list | 0 |
| __DimCurveError_ChF | list | 0 |
| ChannelActive_F | list | 0 |
| Channel F | list | Individual |
| GroupMaster_3 | unsignedInt 0…255 | 0 |
| Channel E scene value | list | Don't change (Not a part of this scene) |
| Channel F scene value | list | Don't change (Not a part of this scene) |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| UD106 Universal Dimming Actuator 1.0 latest | $BC8A | DFB7 | 2026-11-25 | 224 KB | Download |
About this file
This is the official ETS product database for the EAE UD106 Universal Dimming Actuator (48266), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from EAE
- DA100 DALI-Gateway 8-Sensor Slot, Emergency Light 48001
- DA110 DALI-Gateway Individual Control/2.0 48023
- SW108 Switch Actuator 8-Channel 16A 48002
- UI108 Universal Interface,8-Channel 48003
- IPR100 IP Router 48004
- RC0800 Room Control Unit, 8 Output 48011
- RC0808 Room Control Unit, 8 Output, 8 Input 48012
- RC1212 Room Control Unit, 12 Output, 12 Input 48013
- RC1200 Room Control Unit, 12 Output 48014
- XD100 Motion, Brightness Sensor 48022
- RC2018 Room Control Unit, 20 Output, 18 Input 48024
- RC2000 Room Control Unit, 20 Output 48027