KNX Database
EAE 48175 TGPDx | TGPxx Mona Thermostat

TGPDx | TGPxx Mona Thermostat 48175

EAE · Order number 48175 · Thermostat

Mona Series Thermostat: 1-6 Button with LCD Display

Download .knxprod TGPDx | TGPxx Thermostat 1.1 · 297 KB

Product

ManufacturerEAE
Product nameTGPDx | TGPxx Mona Thermostat
Order number48175
Product textTGPDx | TGPxx Thermostat
HardwareThermostat
MediumTwisted Pair
Bus current (mA)25
Rail mountedNo
RegistrationCertified · 2020-10-05
Languagesde-DE, es-ES, fr-FR, it-IT, en-US
Catalog entryM-011E_H-48175-1_HP-BC2F-11-87DF_CI-48175-1
Fingerprint87DF
SHA-256d1f0b4f08bb6d583756fbe615b6e63aa6a49775dab892ce1386b6df05b8d7bbb
First seen2026-11-25
Markets69 markets

Application program: TGPDx | TGPxx Thermostat 1.1

Application number$BC2F
Version1.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters2680
Group objects2778
Group objects (2778)
NoNameFunctionSizeDPTFlags
0In Operation[0, 1]1 Bit1.17 triggerCT
0Button 1Telegr.switch and Status1 Bit1.1 switchCWT
0Button 1Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 1Telegr.switch1 Bit1.1 switchCT
0Button 2Telegr.switch and Status1 Bit1.1 switchCWT
0Button 2Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 2Telegr.switch1 Bit1.1 switchCT
0Button 3Telegr.switch and Status1 Bit1.1 switchCWT
0Button 3Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 3Telegr.switch1 Bit1.1 switchCT
0Button 4Telegr.switch and Status1 Bit1.1 switchCWT
0Button 4Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 4Telegr.switch1 Bit1.1 switchCT
0Button 5Telegr.switch and Status1 Bit1.1 switchCWT
0Button 5Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 5Telegr.switch1 Bit1.1 switchCT
0Button 6Telegr.switch and Status1 Bit1.1 switchCWT
0Button 6Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 6Telegr.switch1 Bit1.1 switchCT
0Button 7Telegr.switch and Status1 Bit1.1 switchCWT
0Button 7Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 7Telegr.switch1 Bit1.1 switchCT
0Button 8Telegr.switch and Status1 Bit1.1 switchCWT
0Button 8Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 8Telegr.switch1 Bit1.1 switchCT
0Button 9Telegr.switch and Status1 Bit1.1 switchCWT
0Button 9Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 9Telegr.switch1 Bit1.1 switchCT
0Button 10Telegr.switch and Status1 Bit1.1 switchCWT
0Button 10Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 10Telegr.switch1 Bit1.1 switchCT
0Button 11Telegr.switch and Status1 Bit1.1 switchCWT
0Button 11Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 11Telegr.switch1 Bit1.1 switchCT
0Button 12Telegr.switch and Status1 Bit1.1 switchCWT
0Button 12Telegr.shutter UP/DOWN1 Bit1.8 up/downCWT
0Button 12Telegr.switch1 Bit1.1 switchCT
0Button 1 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Short Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Short Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Short Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Short Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Short Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Short Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Short Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Short Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Short Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Short Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Short Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Short Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Double Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Double Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Double Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Double Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Double Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Double Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Double Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Double Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Double Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Double Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Double Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Double Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Long Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Long Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Long Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Short Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Short Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Short Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Short Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Short Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Short Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Short Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Short Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Short Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Short Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Short Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Short Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Double Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Double Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Double Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Double Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Double Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Double Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Double Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Double Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Double Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Double Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Double Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Double Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Long Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Long Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Long Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Short Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Short Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Short Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Short Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Short Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Short Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Short Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Short Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Short Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Short Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Short Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Short Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Double Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Double Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Double Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Double Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Double Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Double Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Double Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Double Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Double Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Double Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Double Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Double Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Long Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Long Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Long Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Short Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Short Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Short Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Short Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Short Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Short Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Short Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Short Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Short Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Short Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Short Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Short Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Double Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Double Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Double Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Double Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Double Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Double Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Double Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Double Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Double Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Double Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Double Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Double Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 1 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 1 [Long Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 1 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 1 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 1 [Long Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 1 [Long Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 1 [Long Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 1 [Long Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 1 [Long Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 1 [Long Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 1 [Long Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 1 [Long Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 1 [Long Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 1 [Long Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 1 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 1 [Long Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Short Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Short Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Short Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Short Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Short Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Short Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Short Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Short Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Short Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Short Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Short Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Short Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Double Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Double Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Double Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Double Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Double Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Double Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Double Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Double Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Double Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Double Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Double Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Double Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Long Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Long Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Long Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Short Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Short Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Short Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Short Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Short Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Short Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Short Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Short Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Short Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Short Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Short Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Short Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Double Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Double Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Double Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Double Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Double Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Double Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Double Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Double Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Double Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Double Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Double Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Double Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Long Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Long Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Long Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Short Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Short Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Short Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Short Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Short Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Short Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Short Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Short Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Short Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Short Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Short Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Short Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Double Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Double Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Double Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Double Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Double Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Double Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Double Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Double Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Double Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Double Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Double Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Double Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Long Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Long Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Long Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Short Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Short Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Short Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Short Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Short Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Short Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Short Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Short Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Short Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Short Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Short Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Short Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Double Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Double Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Double Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Double Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Double Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Double Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Double Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Double Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Double Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Double Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Double Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Double Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 2 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 2 [Long Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 2 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 2 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 2 [Long Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 2 [Long Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 2 [Long Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 2 [Long Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 2 [Long Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 2 [Long Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 2 [Long Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 2 [Long Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 2 [Long Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 2 [Long Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 2 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 2 [Long Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Short Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Short Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Short Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Short Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Short Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Short Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Short Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Short Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Short Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Short Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Short Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Short Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Double Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Double Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Double Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Double Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Double Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Double Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Double Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Double Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Double Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Double Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Double Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Double Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Long Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Long Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Long Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Long Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Long Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Long Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Long Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Long Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Long Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Long Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Long Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Long Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Short Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Short Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Short Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Short Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Short Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Short Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Short Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Short Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Short Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Short Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Short Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Short Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Double Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Double Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Double Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Double Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Double Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Double Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Double Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Double Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Double Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Double Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Double Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Double Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Long Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Long Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Long Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Long Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Long Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Long Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Long Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Long Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Long Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Long Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Long Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Long Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Short Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Short Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Short Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Short Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Short Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Short Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Short Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Short Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Short Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Short Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Short Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Short Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Double Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Double Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Double Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Double Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Double Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Double Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Double Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Double Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Double Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Double Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Double Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Double Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Long Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Long Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Long Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Long Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Long Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Long Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Long Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Long Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Long Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Long Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Long Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Long Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Short Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Short Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Short Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Short Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Short Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Short Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Short Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Short Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Short Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Short Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Short Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Short Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Double Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Double Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Double Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Double Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Double Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Double Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Double Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Double Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Double Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Double Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Double Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Double Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 3 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 3 [Long Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 3 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 3 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 3 [Long Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 3 [Long Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 3 [Long Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 3 [Long Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 3 [Long Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 3 [Long Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 3 [Long Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 3 [Long Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 3 [Long Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 3 [Long Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 3 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 3 [Long Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Short Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Short Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Short Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Short Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Short Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Short Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Short Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Short Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Short Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Short Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Short Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Short Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Double Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Double Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Double Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Double Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Double Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Double Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Double Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Double Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Double Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Double Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Double Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Double Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Long Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Long Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Long Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Long Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Long Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Long Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Long Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Long Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Long Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Long Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Long Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Long Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Short Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Short Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Short Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Short Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Short Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Short Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Short Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Short Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Short Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Short Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Short Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Short Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Double Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Double Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Double Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Double Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Double Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Double Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Double Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Double Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Double Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Double Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Double Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Double Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Long Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Long Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Long Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Long Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Long Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Long Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Long Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Long Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Long Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Long Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Long Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Long Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Short Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Short Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Short Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Short Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Short Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Short Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Short Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Short Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Short Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Short Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Short Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Short Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Double Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Double Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Double Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Double Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Double Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Double Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Double Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Double Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Double Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Double Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Double Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Double Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Long Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Long Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Long Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Long Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Long Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Long Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Long Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Long Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Long Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Long Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Long Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Long Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Short Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Short Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Short Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Short Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Short Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Short Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Short Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Short Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Short Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Short Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Short Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Short Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Double Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Double Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Double Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Double Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Double Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Double Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Double Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Double Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Double Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Double Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Double Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Double Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 4 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 4 [Long Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 4 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 4 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 4 [Long Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 4 [Long Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 4 [Long Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 4 [Long Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 4 [Long Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 4 [Long Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 4 [Long Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 4 [Long Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 4 [Long Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 4 [Long Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 4 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 4 [Long Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Short Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Short Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Short Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Short Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Short Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Short Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Short Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Short Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Short Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Short Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Short Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Short Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Short Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Double Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Double Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Double Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Double Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Double Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Double Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Double Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Double Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Double Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Double Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Double Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Double Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Double Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Double Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Long Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Long Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Long Press 1]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Long Press 1]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Long Press 1]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Long Press 1]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Long Press 1]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Long Press 1]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Long Press 1]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Long Press 1]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Long Press 1]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Long Press 1]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Long Press 1]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Long Press 1]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Short Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Short Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Short Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Short Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Short Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Short Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Short Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Short Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Short Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Short Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Short Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Short Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Short Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Short Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Double Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Double Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Double Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Double Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Double Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Double Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Double Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Double Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Double Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Double Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Double Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Double Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Double Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Double Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Long Press 2]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Long Press 2]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Long Press 2]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Long Press 2]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Long Press 2]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Long Press 2]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Long Press 2]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Long Press 2]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Long Press 2]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Long Press 2]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Long Press 2]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Long Press 2]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Long Press 2]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Long Press 2]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Short Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Short Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Short Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Short Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Short Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Short Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Short Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Short Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Short Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Short Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Short Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Short Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Short Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Short Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Double Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Double Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Double Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Double Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Double Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Double Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Double Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Double Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Double Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Double Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Double Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Double Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Double Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Double Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Long Press 3]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Long Press 3]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Long Press 3]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Long Press 3]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Long Press 3]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Long Press 3]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Long Press 3]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Long Press 3]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Long Press 3]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Long Press 3]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Long Press 3]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Long Press 3]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Long Press 3]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Long Press 3]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Short Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Short Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Short Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Short Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Short Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Short Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Short Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Short Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Short Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Short Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Short Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Short Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Short Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Short Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Double Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Double Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Double Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Double Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Double Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Double Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Double Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Double Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Double Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Double Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Double Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Double Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Double Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Double Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 5 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 5 [Long Press 4]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 5 [Long Press 4]Telegr.value[0,1]1 Bit1.1 switchCWT
0Button 5 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CT
0Button 5 [Long Press 4]Telegr.value[-127,128]1 Byte6.10 counter pulses (-128..127)CT
0Button 5 [Long Press 4]Telegr.value HVAC Mode1 Byte20.102 HVAC modeCT
0Button 5 [Long Press 4]Telegr.value[0...100%]1 Byte5.1 percentage (0..100%)CT
0Button 5 [Long Press 4]Telegr.value(1...64 scene)1 Byte18.1 scene controlCT
0Button 5 [Long Press 4]Telegr.value[0,65535]2 Bytes7.1 pulsesCT
0Button 5 [Long Press 4]Telegr.value[-32768,32767]2 Bytes8.1 pulses differenceCT
0Button 5 [Long Press 4]Telegr.value(2-byte float)2 Bytes9.1 temperature (°C)CT
0Button 5 [Long Press 4]Telegr.value(4-byte unsigned)4 Bytes12.1 counter pulses (unsigned)CT
0Button 5 [Long Press 4]Telegr.value(4-byte signed)4 Bytes13.1 counter pulses (signed)CT
0Button 5 [Long Press 4]Telegr.value(4-byte float)4 Bytes14.5 amplitudeCT
0Button 5 [Long Press 4]Telegr.value[0,255]1 Byte5.10 counter pulses (0..255)CWT
0Button 5 [Long Press 4]Telegr.value[0,3]2 Bit2.1 switch controlCT
0Button 6 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCT
0Button 6 [Short Press 1]Telegr.value HVAC Control Mode1 Bit1.100 cooling/heatingCT
0Button 6 [Short Press 1]Telegr.value[0,1]1 Bit1.1 switchCWT

First 1000 of 2778 group objects shown. Download the .knxprod for the full list.

Parameters (340)
ParameterTypeDefault
In Operation TelegramunsignedInt 0…10
In Operation Valuelist1
In Operation Sending IntervalunsignedInt 10…65535300
Telegram LimiterunsignedInt 0…10
Telegram Limit Period Durationlist50 ms
Maximum Telegram Count In PeriodunsignedInt 1…2551
Switch Configurationlist1 Button
Telegram Transmission Delay (after KNX bus recovery)unsignedInt 1…2551
Dark Levellist1 (1.5%)
Bright Levellist7 (100%) = Max
Status LED "Operation Indication" Durationlist0.75 s
Ambient Light SensorunsignedInt 0…10
Custom Levellist1 (1.5%)
Ambient Light DimunsignedInt 0…10
Proximity DimunsignedInt 0…10
Ambient Light DetectionunsignedInt 0…10
SourcelistObject (External)
Send Day/Night StatusunsignedInt 0…10
DPT Day/Night Objectlist0 = Day; 1 = Night [DPT_DayNight]
SendlistOn Change
Diagnostic ModeunsignedInt 0…10
Low Pass Filter Levellist4
ThresholdunsignedInt 1…2558
HyteresisunsignedInt 2…2552
Cyclic Sending IntervalunsignedInt 10…65535300
Day/Night SourcelistObject (External)
AdvancedunsignedInt 0…10
Proximity SensorunsignedInt 0…10
Proximity DetectionunsignedInt 0…10
Send Proximity StatusunsignedInt 0…10
Proximity SourcelistButton Press
Proximity Generator IDlist1
Presence Transmit Repeat IntervalunsignedInt 0…2550
Object Monitoring TimeoutunsignedInt 0…2550
Presence TimeoutunsignedInt 1…25510
Sensor SensitivitylistMedium
Proximity ObjectlistSingle Generator
Firmware Versiontext-----
Day/Night State after KNX Bus RecoverylistReset
Logic BlockslistNone
ets_data_struct_idunsignedInt 0…2551
Temperature UnitlistCelsius ( °C )
Internal Sensor OffsetsignedInt -128…1270
Send TemperaturelistCyclic
Cyclic Sending IntervalunsignedInt 0…6553530
Minimum ChangeunsignedInt 1…2551
Temperature MeasurementlistInternal Sensor
ExternalWeightunsignedInt 0…1000
External Sensor Temperature UnitlistSame
External Sensor Monitoring Timeout*unsignedInt 15…6553515
Temperature Shown on LCDlistInternal Sensor
Temperature Shown on KNXlistInternal Sensor
External Sensor WeightunsignedInt 1…9950
Spot Temperature SensorunsignedInt 0…10
Spot Sensor Temperature UnitlistSame
Heat Limit TemperatureunsignedInt 0…2550
Cool Limit TemperatureunsignedInt 0…2550
Limit Protection Deactivation HysteresisunsignedInt 1…2551
Limit Protection Activation DelayunsignedInt 0…655350
Monitoring TimeoutunsignedInt 15…6553560
Control ModelistHeat
Control Objects of Main StagelistSeparate
Control Objects of Additional StagelistSeparate
heatcool_dpt_dismatchlist0
heatcool_dpt_dismatch_addlist0
Switchover MethodlistAutomatic
Heat/Cool Switchover Hysteresis (+/-)unsignedInt 5…2555
DPT Switchover Objectlist1 Bit [DPT_Heat/Cool]
Switchover Cyclic Sending IntervalunsignedInt 1…2551
Operating ModeslistComfort
DPT Operating Mode Objectlist1 Byte [DPT_HVAC_Mode]
DPT Operating Mode Status ObjectlistBit Objects
heat_bitlist0
heat_bytelist0
cool_bitlist0
cool_bytelist0
heatcool_bitlist0
heatcool_bytelist0
heat_bit_addlist0
heat_byte_addlist0
cool_bit_addlist0
cool_byte_addlist0
heatcool_bit_addlist0
heatcool_byte_addlist0
fan_control_enabledlist0
cool_enabledlist0
cool_enabled_addlist0
heat_enabledlist0
heat_enabled_addlist0
split_heatlist0
split_coollist0
split_heat_coollist0
split_heat_errorlist0
split_cool_errorlist0
split_heatcool_errorlist0
Controller TypelistOn/Off
Control ValuelistNormal
Sending of Control ValuelistCyclic
Cyclic Sending IntervalunsignedInt 1…2555
Transmit on Modificationlist0
Minimum ChangeunsignedInt 1…255
Maximum Control SignalunsignedInt 0…100100
Minimum Control SignalunsignedInt 0…1000
Pwm PeriodunsignedInt 1…25510
Signal Minimum Switching TimeunsignedInt 0…2550
Hysteresis (+/-)unsignedInt 1…25520
Communication Error ObjectlistDisable
Spot Heat ProtectionunsignedInt 0…10
Controller AlgorithmlistI-P
Proportional Gain KpunsignedInt 1…25566
Integral Gain KiunsignedInt 1…25532
SP Action Gainlist1
Positive PV Action BandunsignedInt 5…25566
Proportional BandunsignedInt 1…255100
TiunsignedInt 0…2550
TdunsignedInt 0…25510
Filter Coefficient (N)unsignedInt 2…206
Signal Minimum Switching TimeunsignedInt 0…2554
Additional Stage ActivationlistOn Difference to Setpoint
Hysteresis (+/-)unsignedInt 0…2550
Fan SpeedlistControlled by Main Stage
Fan SpeedlistAuto
Controller Algorithm "On/Off" OverrideunsignedInt 0…10
Controller AlgorithmlistDisabled (Control Value = Max. Control Signal %)
Additional Stage Heat Activation DifferenceunsignedInt 0…2550
Activation Difference (Away from Setpoint)unsignedInt 10…25520
Deactivation Difference (Close to Setpoint)unsignedInt 1…25510
virt_heat_activation_errorlist0
Spot Cool ProtectionunsignedInt 0…10
C_SpotCoolProtection_DisabledunsignedInt 0…10
Controller AlgorithmlistPI-D
C_SpotCoolProtection_Add_DisabledunsignedInt 0…10
Additional Stage Cool Activation DifferenceunsignedInt 0…2550
virt_cool_activation_errorlist0
fancoil_availablelist0
Send Fan Speed CyclicallyunsignedInt 0…10
Cyclic Sending IntervalunsignedInt 1…2551
Also Send Auto-Fan ValueunsignedInt 0…11
FanSpeedSendingPeriodMinunsignedInt 0…2550
Fan Turn Off Action when Control Value is 0listSend Speed=0
Enable Automatic Fan when Control Unit is InactiveunsignedInt 0…10
Writing to Manual Fan Speed Objects when Automatic Fan EnabledlistDisables Automatic Fan
DPT Automatic Fan Speedlist0 = Disable; 1 = Enable [DPT_Enable]
Enumerated ObjectunsignedInt 0…10
Control StylelistFan Coil (0 = Speed 0)
Scaling [%] ObjectunsignedInt 0…10
Control StylelistFan Coil (0% = Speed 0)
Bit ObjectsunsignedInt 0…10
Reset Values of Unselected Fan ObjectslistYes
Optional Method for Turning Off FanlistTransmit "0" at Fan Speed 1
LCD Fan Speed Status from Object (In Automatic Fan)unsignedInt 0…10
Choose DPTlistEnumerated
virt_fancoil_obj_errorunsignedInt 0…10
Send SetpointlistCyclic and Change
Cyclic Sending IntervalunsignedInt 10…6553515360
Setpoint Button Step Valuelist0.5 K
Setpoint Object Step Valuelist0.5 °C
Operating Mode Setpoint ObjectslistDisable
Maximum SetpointunsignedInt 0…990
Minimum SetpointunsignedInt 0…990
virt_setpoint_limit_errorunsignedInt 0…2550
Multi SetpointlistDisable
Multi SetpointlistDisabled (Manual Switchover Only)
After KNX Bus RecoverylistYes
After Operating Mode ChangelistYes
Defaults On Mode ChangelistYes
After Control Mode ChangelistYes
Defaults On Control Mode ChangelistYes
Reset on Site ObjectlistNo
Reset on Site Valuelist0
Setpoint HeatingunsignedInt 0…990
Setpoint CoolingunsignedInt 0…990
SetpointunsignedInt 0…990
Range Limitlist±5 K
Use Above Fan Speed for All Operating ModesunsignedInt 0…10
Range Limitlist±0 K
Protection Deactivation HysteresisunsignedInt 10…25510
Heat Protection LimitunsignedInt 0…990
Frost Protection LimitunsignedInt 0…990
Fan SpeedlistFan Speed 3
Built-in LCD DisplayunsignedInt 0…11
Setpoint ButtonlistEnable
Fan Speed ButtonlistEnable
Operating Mode ButtonlistEnable
virt_local_button_lockedunsignedInt 0…10
virt_no_fan_objectunsignedInt 0…10
Window StatusunsignedInt 0…10
DPT Window Objectlist0 = Closed; 1 = Open [DPT_Window_Door]
Delay for Open ActionunsignedInt 0…655350
Joint OperationunsignedInt 0…10
JointOpSetpointunsignedInt 0…10
JointOpFanSpeedunsignedInt 0…10
JointOpRegulationunsignedInt 0…10
JointOpOperatingModeunsignedInt 0…10
Setpoint SegmentlistEnable
Temperature Segment in Protection ModelistEnable
Temperature Segment during Regulation OfflistEnable
virt_button_countunsignedInt 1…121
Thermocolor changes withlistControl Mode
ColorlistRed
BrightnesslistOff
ColorlistWhite
BrightnesslistBright
Change when Regulation is OffunsignedInt 0…11
Change when in Protection ModeunsignedInt 0…11
Heating/Cooling Colors when Protection is ActiveunsignedInt 0…11
HeatinglistRed
CoolinglistBlue
Regulation OfflistNone
Protection ModelistWhite
Hot/Cold Colors when Protection is ActiveunsignedInt 0…11
Hot (above setpoint)listRed
Cold (below setpoint)listBlue
Target (near setpoint)listWhite
When Regulation is OfflistNone
When in Protection ModelistWhite
Zone (+/-)unsignedInt 1…2552
Ambient Light Sensortext-----
Proximity Sensortext-----
Uptimetext-----
LCD Temperature Unit ObjectunsignedInt 0…10
DPT of Objectlist0 = Celsius; 1 = Fahrenheit
LCD Initial Temperature UnitlistSame
Icon Blinking on Protection ActivationlistEnable
sensor.als.use_default_sensor_settingsunsignedInt 0…10
Setpoint Object Step Valuelist0.5 °F
virt_builtin_sensors_enabledlistFalse
I/O Configlist15 Input / 1 Output
Nametext
Data typelist1-bit
PreprocesslistPassthrough
greater than or equal tounsignedInt 0…2550
less than or equal tounsignedInt 0…255255
match 1unsignedInt 0…2550
match 2unsignedInt 0…2551
maskunsignedInt 1…2551
False if <=unsignedInt 0…255100
True if >=unsignedInt 0…255128
Initial statelistFalse
State after KNX bus recoverylistInitial
RegisterunsignedInt 0…10
IN1 {{0:}}unsignedInt 0…10
IN2 {{0:}}unsignedInt 0…10
IN3 {{0:}}unsignedInt 0…10
IN4 {{0:}}unsignedInt 0…10
IN5 {{0:}}unsignedInt 0…10
IN6 {{0:}}unsignedInt 0…10
IN7 {{0:}}unsignedInt 0…10
IN8 {{0:}}unsignedInt 0…10
IN9 {{0:}}unsignedInt 0…10
IN10 {{0:}}unsignedInt 0…10
IN11 {{0:}}unsignedInt 0…10
IN12 {{0:}}unsignedInt 0…10
IN13 {{0:}}unsignedInt 0…10
IN14 {{0:}}unsignedInt 0…10
IN15 {{0:}}unsignedInt 0…10
REG OUT2 {{0:}}unsignedInt 0…10
REG OUT3 {{0:}}unsignedInt 0…10
REG OUT4 {{0:}}unsignedInt 0…10
REG OUT5 {{0:}}unsignedInt 0…10
REG OUT6 {{0:}}unsignedInt 0…10
REG OUT7 {{0:}}unsignedInt 0…10
REG OUT8 {{0:}}unsignedInt 0…10
REG OUT9 {{0:}}unsignedInt 0…10
REG OUT10 {{0:}}unsignedInt 0…10
REG OUT11 {{0:}}unsignedInt 0…10
REG OUT12 {{0:}}unsignedInt 0…10
REG OUT13 {{0:}}unsignedInt 0…10
REG OUT14 {{0:}}unsignedInt 0…10
REG OUT15 {{0:}}unsignedInt 0…10
STATEunsignedInt 0…10
Descriptiontext
OperationlistPassthrough (unary)
Triggerlistoperand update
Sending blocked whenlistIN1
Send pending telegram after unblockingunsignedInt 0…10
Send value when expression islistTrue or False
False valuelist0
False valueunsignedInt 0…2550
False valuelist00b (No Priority, False)
True valuelist1
True valueunsignedInt 0…2551
True valuelist01b (No Priority, True)
Send only on changeunsignedInt 0…10
Send initial state after KNX bus recoveryunsignedInt 0…10
Timerlistnone
active when expression islistTrue or False
active when expression islistTrue
REG OUT1 {{0:}}unsignedInt 0…10
Button Lock ObjectunsignedInt 0…10
Button Lock Object DPTlist0 = Unlock; 1 = Lock
Lock State after KNX Bus RecoverylistKeep
LED Function when LockedlistActive
Button FunctionlistNo Function
Command on PresslistToggle
Command on ReleaselistNo Command
Function of LEDlistStatus Indication
Separate Switch Status ObjectunsignedInt 0…10
Dim OperationlistDarker/Brighter (Short Press Toggle)
Long Press Durationlist500 ms
Dimming TypelistStart Stop
Step Valuelist12.5 %
Step Send Intervallist1 s
Shutter FunctionlistToggle
Control TypelistShutter/Venetian blind
Long Press Durationlist300 ms
Function of LEDlistStatus and Movement Indication
Function of LEDlistOperation Indication
virt_button.shutter_led_infolistNo Info
Long Press RepeatunsignedInt 0…10
Value 1listShort Press
Value 2listNone
Value 3listNone
Value 4listNone
Long Press Durationlist1 s
Long Press Repeat Intervallist200 ms
Double Press TimeoutunsignedInt 20…20020
virt_valueop_enabled_eventslistShort Press Only
Button Lock Object Transmits StatusunsignedInt 0…10
Data Typelist1-bit
Valuelist0
ValuelistCool
Beginlist1
BeginunsignedInt 0…2550
Counting SequencelistCyclic
EndunsignedInt 0…255255
StepunsignedInt 0…2551
Step DirectionlistUp
ValuelistAuto
ValueunsignedInt 0…1000
SceneunsignedInt 1…641
ValuesignedInt -128…1270
ValueunsignedInt 0…2550
Valuefloat -671088…6707600
ValuesignedInt -32768…327670
ValueunsignedInt 0…655350
Valuefloat -1e+38…1e+380
ValuesignedInt -2147483648…21474836470
ValueunsignedInt 0…42949672950
Valuelist00b (No Priority, Off)

Version history

ApplicationApp noFingerprintFirst seenSizeFile
TGPDx | TGPxx Thermostat 3.0 latest$BC2F2EE62026-11-25684 KBDownload
TGPDx | TGPxx Thermostat 2.0$BC2F2A122026-11-25480 KBDownload
TGPDx | TGPxx Thermostat 1.1$BC2F87DF2026-11-25297 KBDownload

About this file

This is the official ETS product database for the EAE TGPDx | TGPxx Mona Thermostat (48175), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from EAE

All EAE products